Secrure door control and I/O expansion

Installation Guide
(ver 1.0)

www.supremainc.com
Product Contents 3
Front Panel Description 4
Rear Panel Description 5
Connectors for External Interfaces 6
Contents
Installation Example 8
Product Dimension 9
Power Connection 10
RS-485 Connection 11
Relay Connection 12
RTE Switch Connection 14
Fire Alarm Connection 15
System Specifications 16

ⒸCopyright 2010 Suprema Inc.


Product Contents

„ Basic Contents

Product Contents

Wall mounting screws

120 Ohm Resistor & Diode


Secure I/O

ⒸCopyright 2010 Suprema Inc.


Front Panel Description

RLY0 LED - Status of Relay0


RLY1 LED - Status of Relay1
RX LED - Status of RS-485 Rx signal
TX LED - Staus of RS-485 Tx signal
IN0 LED - Status of Input0
IN1 LED - Status of Input1
IN2 LED - Status of Input2
IN3 LED - Status of Input3
PWR LED - Power status
RUN LED - Status of Secure I/O operation

RESET BUTTON - Secure I/O hardware reset


SYNC BUTTON - Syncronization between Secure I/O and dev
ice (BioStation/ BioEntry Plus) for security by exchanging an e
ncryted keys. This prevents the operation of Secure I/O when
the external device has been exchanged by an intruder. Sync
button should be pressed when a device is set as a host in a
RS-485 loop.

ⒸCopyright 2010 Suprema Inc.


Rear Panel Description

ID0 / ID1 - Dip switch to set an ID of Secure I/O


Since max number of Secure I/O in an RS-485 loop is four,
the ID of Secure I/O should be set among 0, 1, 2, 3.

RSV - reserved for future use

Secure I/O ID setting

ID = 0 ID = 1

ID = 2 ID = 3

ⒸCopyright 2010 Suprema Inc.


Connectors for External Interfaces 1

N.O 0 IN 0+
Relay Output0 Normal Open
COM 0 IN 0-
Relay Output0 Common
N.C 0 RLY0 IN0 IN 1+
Relay Output0 Normal Close
N.O 1 RLY1 IN1 IN 1-
Relay Output1 Normal Open RESET
COM 1 IN2 IN 2+
Relay Output1 Common
N.C 1 IN3 IN 2-
Relay Output1 Normal Close
TRX+ IN 3+
RS-485 TRX+ RX IN0
TRX- IN 3-
RS-485 TRX- TX IN0 SYNC
TRXGND
RS-485 Ground
FGND
Frame Ground
PWR+
Power Input+
PWR-
Power Input -

ⒸCopyright 2010 Suprema Inc.


Connectors for External Interfaces 2

N.O 0 IN 0+
External Input 0 +
COM 0 IN 0-
External Input 0 -
N.C 0 RLY0 IN0 IN 1+
External Input 1 +
N.O 1 RLY1 IN1 IN 1-
RESET External Input 1 -
COM 1 IN2 IN 2+
External Input 2 +
N.C 1 IN3 IN 2-
External Input 2 -
TRX+ IN 3+
RX IN0
External Input 3 +
TRX- IN 3-
TX IN0 SYNC
External Input 3 --
TRXGND

FGND

PWR+

PWR-

ⒸCopyright 2010 Suprema Inc.


Installation Example

Relay Output Door Lock

RS-485

BioStation or Secure I/O


BioEntry Plus
Exit Button
External Input

ⒸCopyright 2010 Suprema Inc.


Product Dimension

Top

Side

(unit : mm)

ⒸCopyright 2010 Suprema Inc.


Power Connection

Earth Ground

DC 12V Power Source


DC 12V Positive

DC 12V Negative

Recommended power supply


z 12V ± 10%, at least 500mA for Secure IO alone installation.
z Comply with standard IEC/EN 60950-1

z To share the power with other devices, use a power supply with higher current ratings.

10

ⒸCopyright 2010 Suprema Inc.


RS-485 Connection

N.O 0

COM 0

N.C 0

N.O 1

COM 1
RS-485 TRX+
N.C 1
120 Ohm
TRX+
RS-485 TRX- resistor
TRX-

RS-485 Ground TRXGND

PWR+
BioStation or BioEntry Plus PWR-

z In case the length of RS-485 line is so long to affect communication stability, connect the
enclosed 120 Ohm resistor between TRX+ and TRX- connector of Secure I/O

11

ⒸCopyright 2010 Suprema Inc.


Relay Connection – Fail Secure Lock

- + + -

Dead Bolt / DC Power


Door Strike Source

z Whenusing dead bolt or door strike, connect an enclosed diode as in the above diagram.
Anode (line mark) of the diode should be connected to + power (Be careful of the direction)

12

ⒸCopyright 2010 Suprema Inc.


Relay Connection – Fail Safe Lock

- + + -

Deal Bolt / DC Power


Door Strike Source

z Whenusing dead bolt or door strike, connect an enclosed diode as in the above diagram.
Anode (line mark) of the diode should be connected to + power (Be careful of the direction)

13

ⒸCopyright 2010 Suprema Inc.


RTE Switch Connection

RTE Switch or
Exit Button

14

ⒸCopyright 2010 Suprema Inc.


Fire Alarm Connection

Alarm Output+
Alarm Output-

Fire Alarm System

15

ⒸCopyright 2010 Suprema Inc.


System Specifications

„ CPU : 8bit, 16MHz Microcontroller


„ Memory : 32Kbyte Flash
„ Display : 10ea Status LED
„ IO : Input X 4Ch, Output X 2Ch, RS-485 X 1Ch
„ Product size : 142.5 x 110 x 39 mm (width x length x depth)

Min. Typ. Max. Notes

Power

Voltage (V) 10.8 12 13.2

Current (mA) - 500 800

Relay

5A 125VAC
Normal switching
- 2A 250VAC
capacity(N.O) (Resistive)
3A 30VDC

2A 125VAC
Normal switching
- 1A 250VAC
capacity(N.C) (Resistive)
1A 30VDC

16

ⒸCopyright 2010 Suprema Inc.


Suprema Inc.
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 Korea
E-mail : [email protected]
Website : www.supremainc.com

Functions and specifications of the product are subject to changes without notice due to quality