0% found this document useful (0 votes)
63 views2 pages

X3-Forth V2.5

The Solax X3-FORTH photovoltaic inverter system provides efficient solar energy harvesting with maximum efficiency up to 99% and voltage range of 180-1000Vdc. It features 12 maximum power point trackers, 150% oversizing input and 110% overloading output. Safety measures include IP66 protection, AFCI protection and temperature monitoring. The system allows for remote access and monitoring of power production and diagnostics. It has a lightweight and compact design using advanced cooling and power control.

Uploaded by

irfan afzal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views2 pages

X3-Forth V2.5

The Solax X3-FORTH photovoltaic inverter system provides efficient solar energy harvesting with maximum efficiency up to 99% and voltage range of 180-1000Vdc. It features 12 maximum power point trackers, 150% oversizing input and 110% overloading output. Safety measures include IP66 protection, AFCI protection and temperature monitoring. The system allows for remote access and monitoring of power production and diagnostics. It has a lightweight and compact design using advanced cooling and power control.

Uploaded by

irfan afzal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

NEW FROM SOLAX

X3-FORTH

Features
More energy harvest
Maximum efficiency up to 99%
180~1000Vdc MPPT voltage range
Maximum 12 MPPTs, 2 strings per MPP tracker
150% PV oversizing input, 110% overloading output
Maximum 32A MPPT current, 16A per string

Safety & Reliability


IP66 protection level
AFCI protection (Optional)
AC terminal temperature detection
Both AC & DC SPDs (Type II) inside, Type I SPD is optional

Intelligence for easy maintenance and economy


Built-in export power control
Remote setting and upgrading
24 hours operation monitoring
Smart I-V Curve Diagnosis supported
SVG functional supported (Optional)
Aluminium AC cable connection available
Power line communication (PLC)(Optional)
X3-FORTH Fuse free design with smart string current monitoring
Smart air cooling technique results in long lifetime of fans
80kW/100kW/110kW Advanced heat dissipation technology makes the system more than 5% lighter
120kW/125kW/136kW/150kW and smaller

Contact Us for More Information


[email protected]
[email protected] www.solaxpower.com Global: +86 571-56260008
AU: +61 1300 476529 UK: +44 2476 586998
DE: +49 6142 4091664 NL: +31 (0) 852 737932
X3-FORTH (THREE PHASE)

X3-FTH-125K X3-FTH-136K-MV X3-FTH-150K-MV


DC INPUT

Max. PV array input power [kWp] 120 150 165 180 188 204 225
Max. PV input voltage [V] 1100 1100 1100 1100 1100 1100 1100
Startup voltage [V] 200 200 200 200 200 200 200
Nominal input voltage [V] 580/600 580/600 580/600 580/600 580/600 730/785 730/785
MPP tracker voltage range [V] 180~1000 180~1000 180~1000 180~1000 180~1000 180~1000 180~1000
No. of MPP trackers 9 9 9 12 12 12 12
Strings per MPP tracker 2 2 2 2 2 2 2
Max. input current per MPPT [A] 32 32 32 32 32 32 32
Max. short circuit current per MPPT [A] 46 46 46 46 46 46 46

AC OUTPUT

Nominal AC output power [kW] 80 100 110 120 125 136 150
Nominal AC output current [A] 121.3/116 151.6/145 166.7/159.5 181.9/174 189.4/181.2 157.1/145.4 173.2/160.4
Max. AC output apparent power [kVA] 88 110 121 132 132 149.6 165
Max. AC output current [A] 133.4/127.6 166.7/159.5 183.4/175.4 200/191.3 200/191.3 172.8/160 190.6/176.5
Nominal AC voltage[V] 220/380, 230/400, 3/N/PE, 3/PE 500/540,3P3W+PE 500/540,3P3W+PE
Nominal grid frequency [Hz] 50/60
Displacement power factor 0.8 leading-0.8 lagging
THDi (Rated power) [%] <3

SYSTEM DATA

MPPT efficiency [%] 99.9


Max. efficiency [%] 98.6 98.6 98.6 98.6 98.6 99.0 99.0
Ingress protection IP66
Operating temperature range [OC] -25~+60 (Derating at 45)
Max. operation altitude [m] 4000 (Derating above 3000)
Relative humidity [%] 0~100
Dimensions[W×H×D] [mm] 985×660×327.5
Weight [kg] 83 83 83 87 87 87 87
Cooling concept Smart fan cooling
Communication interfaces RS485 / (Optional: Pocket Wifi/4G) / Bluetooth / USB

PROTECTION

Over/under voltage protection YES


DC isolation protection YES
Grid monitoring YES
DC injection monitoring YES
Residual current detection YES
Anti-islanding protection YES
String fault detection YES
SPD (DC/AC) Type II / Type II
Output terminals over temperature detection YES

STANDARD

Safety IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004


EMC IEC/EN 61000; NB/T 32004
Certification EN 50549; AS4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004

*V2.5 Information may be subject to modify without notice.650.00001.00