Method Statement Sikadur 52 KE
Method Statement Sikadur 52 KE
Method Statement Sikadur 52 KE
Date: 05/2015
Sikadur® -52
Construction
Scope: Low viscosity injection resin for sealing vertical cracks with width less
than 0.5mm
1.1 Clean out surfaces, using small wire brushes or compressed air to
remove all loose and friable materials, as well as mud and other
impurities.
1.2 Concrete surfaces must be clean, free from standing water and all
loosely adhering particles.
1.3 The cracks and adjacent substrate must be clean, sound and free of
frost. Remove dust, laitance, grease, curing compounds, waxes,
impregnations, foreign particles, efflorescence and other bond inhibiting
materials from the surface by mechanical means, i.e. - sandblasting,
high pressure water blasting, etc., as approved by the Engineer.
Epoxy resin adhes ive - repair area may be dry or damp, but free of
standing water prior to product application. (Fig. 1)
The information, and, in particular, the recomm endations relating to the applica tion and end-use of Sika
products, are given in good faith based on Sika's curr ent kno wledge and experience of the products when
properly stored, handled and a pplied under no rmal conditions . In practice, the differences in materials,
substrates and actual s ite conditions are such tha t no warranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from
this information, or from any written recommendations, or from any other advice offered. The proprietary rights
of third parties must be observed. A ll orders are accepted subje ct to our current terms of sale and delivery.
Users should alw ays refer to th e most recent iss ue of the Product Data Sheet f or the product concerned,
copies of which will be supplied on request
Fig. 1
Construction
Injection
Holes
Surface Preparation
2. Execution
Mixing the epoxy res in adhes ive for sealing the cracks. Premi x each
component. Proportion two par ts of Component “A” to one part
Component “B” into a clean, dry mixing pail. Mix thoroughly for 3
minutes min. on a low speed (400-600 rpm) drill. Mix only that quantity
of material that can be used within its pot life (refer to technical data
sheet)
2.2 Application
Using Sikadur® -52 (A two components, solvent free low viscosity
injection) liquid, based on high strength epoxy resins, complies with the
ASTM – C – 881 – 78 Type I, Grade 1 Class B+C).
Crack
Filler
Cap
Construction
Notes:
Sika .HQ\D
Technical Department