How Do I Configure Power Management With - IMM2 - Management Module - On An IBM System x3750 M4 Server in RHEV 3
How Do I Configure Power Management With - IMM2 - Management Module - On An IBM System x3750 M4 Server in RHEV 3
$
RED HAT CUSTOMER PORTAL
0 Issue
How do I configure power management with "IMM2" management module on an IBM System
x3750 M4 server in RHEV 3.1?
Power Management on an IBM System x3750 M4
I have everything working, but i cant seem to figure out power management. The system
reports that it has an "IMM2" management module. Which i've used manually to control the
server. I cant seem to get RHEV to interact with it.
Environment
Red Hat Enterprise Virtualization 3.1
"IMM2" management module
IBM System x3750 M4 server
, Resolution
1. Enable fencing device in the IMM2 web configuration tool.
2. Create a user with admin privilege to connect with ipmilan(IIM2)
3. Permissions for fence user on the imm2 card. Refer below image:
4. Follow the instruction as mentioned in following document for configuring Power Management
Settings and make sure 'ipmilan` agent is selected:
https://access.redhat.com/site/documentation/en-US/Red_Hat_Enterprise_Virtualization/3.1/html-single/Administration_Guide/index.html#As
Root Cause
Fence user permission was not set properly.
https://access.redhat.com/site/solutions/345553 1/4
13/6/19 How do I configure power management with "IMM2" management module on an IBM System x3750 M4 server in RHEV 3.1? - Red Hat Customer Portal
Diagnostic Steps
IPMI connects over 623 port. Check if this port is open in firewall.
Ping test to management server from node.
Test the fence_ipmilan script manually from node:
https://access.redhat.com/site/solutions/345553 2/4
13/6/19 How do I configure power management with "IMM2" management module on an IBM System x3750 M4 server in RHEV 3.1? - Red Hat Customer Portal
a4 a3 a2 a0 14 05 66 65 6e 63 65
>> rakp3 mac key (20 bytes)
32 36 58 31 39 79 46 79 69 4d 6b 6b 00 00 00 00
00 00 00 00
generated rakp3 mac (20 bytes)
10 65 4c f0 a7 5d df 69 07 36 ae 6f b1 6c f7 2d
f1 34 2c c6
session integrity key input (39 bytes)
57 eb 72 21 ca c1 02 24 9c 44 0c 9a fd ae 8a 3e
b4 9a 9f 43 7e cd 87 53 d1 39 a6 0f d3 07 49 dd
14 05 66 65 6e 63 65
Generated session integrity key (20 bytes)
58 c9 3b 0b 3e 0b 0f a7 66 16 70 e8 32 45 94 42
a4 6c 19 42
Generated K1 (20 bytes)
ed 3a 97 1f ef 0c 11 81 8f ce 26 37 d5 51 12 e6
eb 92 69 f0
Generated K2 (20 bytes)
58 39 78 ab ee 57 4f b6 80 41 39 5c 25 04 b4 42
08 08 42 1b
>> SENDING A RAKP 3 MESSAGE
BUILDING A v2 COMMAND
>> Initialization vector (16 bytes)
88 38 2d 13 34 3a bb 94 74 89 5e ec 40 57 0f d7
authcode input (48 bytes)
06 c0 00 0e 00 03 03 00 00 00 20 00 88 38 2d 13
34 3a bb 94 74 89 5e ec 40 57 0f d7 d5 3f 89 74
2d af ea 2e 96 5d c2 44 9e 63 6f 10 ff ff 02 07
authcode output (12 bytes)
9b 5f f1 dc ba 59 a9 fc 80 3a e2 9b
<< IPMI Response Session Header
<< Authtype : Unknown (0x06)
<< Payload type : IPMI (0)
<< Session ID : 0xa0a2a3a4
<< Sequence : 0x00000001
<< IPMI Msg/Payload Length : 32
<< IPMI Response Message Header
<< Rq Addr : 81
<< NetFn : 07
<< Rq LUN :0
<< Rs Addr : 20
<< Rq Seq : 01
<< Rs Lun :0
<< Command : 3b
<< Compl Code : 0x81
Set Session Privilege Level to ADMINISTRATOR failed: Unknown (0x81)
Error: Unable to establish IPMI v2 / RMCP+ session
Unable to get Chassis Power Status
<<OPEN SESSION RESPONSE
<< Message tag : 0x00
<< RMCP+ status : no errors
<< Maximum privilege level : admin
<< Console Session ID : 0xa0a2a3a4
<< BMC Session ID : 0x03000e00
<< Negotiated authenticatin algorithm : hmac_sha1
https://access.redhat.com/site/solutions/345553 3/4
13/6/19 How do I configure power management with "IMM2" management module on an IBM System x3750 M4 server in RHEV 3.1? - Red Hat Customer Portal
<< Negotiated integrity algorithm : hmac_sha1_96
<< Negotiated encryption algorithm : aes_cbc_128
<<RAKP 2 MESSAGE
<< Message tag : 0x00
<< RMCP+ status : no errors
<< Console Session ID : 0xa0a2a3a4
<< BMC random number : 0xb49a9f437ecd8753d139a60fd30749dd
<< BMC GUID : 0x4c174cd0d67f11e1835ee41f13da39ea
<< Key exchange auth code [sha1] : 0xad54443346fda377e8fd580760c56bdcd0a95cbc
<<RAKP 4 MESSAGE
<< Message tag : 0x00
<< RMCP+ status : no errors
<< Console Session ID : 0xa0a2a3a4
<< Key exchange auth code [sha1] : 0xf5ddde3cd1637f142568d8b2
<<<<<
Error = 2 (No such file or directory)
Reaping pid 2617
Chassis power = Unknown
Failed
Add below to Options in GUI while configuring 'Power Management' for hypervisor:
lanplus power_wait=4
Comments
Submit comment
https://access.redhat.com/site/solutions/345553 4/4