DATA SHEET

CodeManagement MODULE ™

For use with Lifepak® 20/20e Defibrillator/Monitors

• Waveform capnography The Code Management System from Physio-Control helps your hospital improve
• Wireless connectivity your preparedness, response and post-event review of codes – helping you not
• Works with any existing 20 or 20e only manage them effectively, but learn from each so that you improve your
team’s skills on the next.

The CodeManagement Module for the • LIFEPAK 20 and 20e devices with
LIFEPAK 20 and 20e defibrillator/monitors CodeManagement Module provide
is a critical part of this system. It adds rescuers with the AHA’s recommended
technologies to the 20 and 20e that rate of 100 compressions per minute
contribute to your hospital’s ability to with a metronome
effectively manage codes from • LIFEPAK 20 and 20e devices with
preparedness through review: CodeManagement Module effectively
• Effectively monitor endotracheal document event timepoints and
tube placement and provide manage CPR intervals with a larger,
rescuers with real-time feedback on highly visible code clock
compression efficacy with Oridion’s
Microstream® continuous waveform The CodeManagement Module can
capnography monitoring be added to any LIFEPAK 20 or 20e
device whether you’ve owned it for many
• LIFENET® Asset wirelessly monitors years or purchased it today, you can add
device data including battery charge valuable technologies that will improve
status, updates and self-tests your organization’s effectiveness in critical
• Wirelessly send patient data to code situations.
CODE-STAT™ data review software to
debrief with the responding team and
document quality improvement initiatives
CodeManagement MODULE TM

SPECIFICATIONS
CodeManagement
MODULE TM

PHYSICAL CHARACTERISTICS CO 2 monitoring data management and transmission


CodeManagement Module adds 3.6 lb (1.63kg) to Drift of Measurement Accuracy: No drift in accuracy for The LIFEPAK 20/20e device captures and stores patient data,
LIFEPAK 20/20e defibrillator/monitors. at least 6 hours events (including waveforms and annotations), and continuous
Size (maximum) of LIFEPAK 20/20e device with Respiration Rate Accuracy: 0 to 70 bpm: ±1 bpm ECG and CO 2 waveform records in internal memory.
CodeManagement Module 71 to 99 bpm: ±2 bpm Wireless data transmission via LIFENET network
Height: 10.0 in (25.4cm) Respiration Rate Range: 0 to 99 breaths/minute
Width: 10.3 in (26.2cm) C0 2 Range: 0 to 99 mmHg (0 to 13.2 kPa)
WIRELESS NETWORKS
Depth: 11.7 in (29.7 cm) Units: mmHg, %, or kPa
Flow Rate: 42.5 to 65 ml/min (measured by volume) The LIFEPAK 20/20e with the CodeManagement Module
supports the following:
Rise Time: 190 msec
DISPLAY • 802.11a, b, g, and n wireless networking standards
Response Time: 4.5 seconds maximum (includes delay time
With CodeManagement Module, the LIFEPAK 20e and rise time) • Security types:
defibrillator/monitor displays a minimum of 3.7 seconds of ECG Initialization Time: 30 seconds (typical), 10–180 seconds - Open
and alphanumerics for values, device instructions, or prompts - WPA-Personal
Ambient Pressure: Automatically compensated internally
Waveform display sweep speed: 12.5 mm/sec for CO 2 - WPA2-Personal
Waveform Scale Factors: Autoscale, 0–20 mmHg (0–4 Vol%),
0–50 mmHg (0–7 Vol%), 0–100 mmHg (0–14 Vol%) - WPA-Enterprise
power - WPA2-Enterprise
C0 2 Accuracy • Enterprise authentication protocols:
LIFEPAK 20/20e defibrillator/monitor with
CodeManagement Module CO2 PARTIAL - EAP-TLS
AC Powered: 100–120 VAC 50/60Hz, 220–240 VAC 50/60 Hz, PRESSURE AT ACCURACY: - EAP-TTLS
total power draw less than 150 Volt-Amperes (VA) SEA LEVEL:
- PEAP/MSCHAPv2
Internal Battery Backup: Lithium-ion. Batteries charge while (0–80 bpm)* 0 to 38 mmHg (0
±2 mmHg (0.27 kPa) • TCP/IP support
device operates from AC Power. to 5.1 kPa)
39 to 99 mmHg ±5% of reading + 0.8% - Internet Protocol Version 4 (IPv4)
Low Battery Indication and Message: When the device is
unplugged from AC power, it switches to battery. When battery (5.2 to 13. kPa) for every 1 mmHg (0.13 - IP addressing: automatically obtains IP address or a static
gets low on the CodeManagement Module, the defibrillator kPa) above 38 mmHg (5.2 address may be assigned.
indicates with a message to connect to AC power in the status to 13. kPa) - D
 NS servers: automatically obtains DNS server address,
area, and a warning tone occurs. (>80 bpm)* 0 to 18 mmHg (0 or static addresses of the primary and secondary DNS
±2 mmHg (0.27 kPa)
Battery charge time: <4 hours when device is powered off and to 2.4 kPa) servers may be assigned.
AC power is applied 19 to 99 mmHg ±4 mmHg (0.54 kPa)
(2.55 to 13.3 or ±12% of reading,
Operating time: A new fully-charged internal backup battery
kPa) whichever is higher
will provide at least 210 minutes of monitoring prior to
shutdown. *For RR > 60 bpm, to achieve specified C02 accuracy, the
Microstream® Filterline® H Set for infants must be used.

For further information, please contact Physio-Control at 800.442.1142 (U.S.), 800.895.5896 (Canada) or visit our website at www.physio-control.com.

Physio-Control Headquarters Physio-Control Canada


11811 Willows Road NE Physio-Control Canada Sales, Ltd.
Redmond, WA 98052 7111 Syntex Drive, 3rd Floor
www.physio-control.com Mississauga, ON
L5N 8C3
Customer Support
Canada
P. O. Box 97006
Toll free 800 895 5896
Redmond, WA 98073
Fax 866 430 6115
Toll free 800 442 1142
Fax 800 426 8049

Physio-Control, Inc., 11811 Willows Road NE, Redmond, WA 98052 USA

©2013 Physio-Control, Inc. All names herein are trademarks or registered trademarks of their respective owners.
Specifications subject to change without notice.
GDR 3314657_B