1048,Kadoma,Osaka 571-8686,Japan ● Please read this manual carefully, and use this product correctly and safely.
● Please read ” Safety Precautions ” before using.
ⓒ Panasonic Electric Works Co., Ltd. 2010
● After installation and setting, please give this manual to the operator or manager.
8A3 971 0000 1 DC 0110−0 PEW
Table of Contents
Brightness setting You can adjust the brightness of the screen light. …………………………… 24
Safety Precautions / Usage Notes ……………………………………………………… 4
Character position setting You can select the position of characters for switch name. ………… 25
Wiring Diagram and Cautions for Installations ……………………………… 5
Installation
Type of Settings…………………………………………………………………………… 10 - 11
Read / Write setting data with SD Memory Card
Settings ……………………………………………………………………………………………… 12 You can write the setting data to SD Memor y Card.
Address Setting For each switch, Individual(0-1 - 63-4), Group(1-127), Pattern(1-72), You can read the setting data from SD Memor y Card.
Dimmer(1-16)can be set. Shut down the system before inserting or removing SD Memory Card ………………… 30
(Individual Switch)Individual …………………………………………………………… 13 How to insert or remove SD Memory Card ……………………………………………… 31
(Pattern / Group Switch)Pattern ……………………………………………………… 14 How to write the setting data to SD Memory Card ……………………………………… 32
(Pattern / Group Switch)Group ………………………………………………………… 15 How to read the setting data from SD Memory Card …………………………………… 33
(Dimmer Switch)Dimmer(Individual)…………………………………………………… 16 File format of reading and writing …………………………………………………… 34
(Dimmer Switch)Dimmer(Group)……………………………………………………… 17 How to edit the setting data written to SD Memory Card ……………………………… 35
(Dimmer Switch)Dimmer ……………………………………………………………… 17 The setting data that can be read and written(Factory default settings) ………… 36 - 37
Setting Switch Name You can set the name of each switch. ………………………………… 18 System
Setting Dialog box Dialog box is displayed when operating in the normal screen.
Setting Page Name You can set the name of each page. …………………………………… 19 The operational error can be prevented. ……………………………… 38
Setting Switch Type How to change the password You can arbitrarily change the password. …………………… 39
How to merge switches You can make the big size switch. ……………………………… 20 Maintenance
How to divide a switch You can return the merged switch to default switches. …………… 21 Initialization You can initialize the settings.(Factory default settings) …………………………… 40
Setting switch color You can set the switch color "Yellow","Blue",and "Default Color". ……… 21 Screen adjustment You can adjust the touching point when it is not pointing properly. …………… 40
2 3
Safety Precautions Wiring Diagram and Cautions for Installations
Power
WARNING source
WRT4124-8 etc.
(6A Contact Output T/U)
Load
24 V AC line
Power
source 24 V
●Do not attempt to take apart, repair or modify this product AC line
under any circumstances. WR2301-811 etc.
Remote Control
Prohibited
Transformer: Not for U.S.A
■ For U.S.A
WRT5554-8 etc.
(Switches)
●Do not install outdoors or in moistured areas. φ1.2 mm - φ1.6 mm、1.25 mm2 - 2.0 mm2 100 m φ1.2 mm - φ1.6 mm、1.25 mm2 - 2.0 mm2 100 m
4 5
Names and Functions Mounting
90+50
Power Block
The connector in the Power Block has a
"Dust cover" installed. LCD Touch Panel Block
When installing the LCD Touch Panel
Block, please remove.
Plate
(WTC9222-8 etc.)
[Optional]
Back Side
(Power Block) (LCD Touch Panel Block)
Signal terminals
●Connect FULL-2WAY
signal
24 V AC terminals
●Connect 24 V AC
power supply
Up to 3 I n iti a l sc re e n
tabs can be used. ●Please set the switch address.
You can operate switches Sales
Meeting
by touching the screen.
1F
Room 1 Division 1
Status (Green)
Meeting Sales ●When "Individual","Group" is
Room 2 Division 2
off or "Pattern" does not match.
2F
Legal Reference
Position Indicator (Green) Division Room
●Even when the screen
Accounting All lights
3F
has been turned off in OFF
Division Status (Red)
the dark, the switch can
●When "Individual","Group" is
be located.
on or "Pattern" is matching.
※Blinks while in timer mode. Addressing setting Easy setting
●The switch shape appears when the
Setting Button switch address is set.
●It shifts to "SETTING mode" and "CLEAN mode".
●Maximum of eight switches can be
You can select the color of the screen. set per page.
The coloration can be set to "White" , "Silver Gray" or "Dark Brown".
(Brightness can be adjusted.)
You can display the various size switches on the screen.(Detailed setting)
●You can make a dimmer swich with standard switches.
●Various size switches are available.
1F
Sales Room 1 Division 1
the name is displayed on the switch.
ON
Division
Switch size
●When the page name is input, Meeting Sales
●You can set various size switches. Room 2 Division 2
2F
2F
Reference
OFF
3F
ON
3F
Room
●You can display the state of loads with Division OFF
characters.
8 9
Type of Settings
Please select " Easy setting" or "Detailed setting".
" Easy setting" is included in "Detailed setting".
Please select, according to situations.
You can set variously in "SETTING mode".When you begin setting or change the settings,
please change the screen to "SETTING mode". Steps to the Address Setting / Individual Switch
Address
Steps to "SETTING mode" Easy setting Select Page
Setting SETTING Enter Password
Button mode
Back Back OK Detailed
Address Select Page
Please enter the password.
setting
2
Meeting Sales
1F
Legal Reference
Division Room
6 7 8 9 0
1
Accounting All lights
Individual
3F
Division OFF
SETTINGS
Switch 4 Switch 8 ※ If you want to change the
Address Unset Address Unset 9 0 −
address that has already
Please select the button. Press the switch you want to set. 2 3 been entered, press "Clear"
and enter address.
( )
Easy Detailed Please read
setting setting
Type of Settings : P.10 - P.11 When you set the timer ... When you do not set the timer ...
How to Settings : P.13 - P.40
5 Press "OK".
※Settings are saved.
Ind. Dim. 1 2 3 4
OFF-Delay
30sec 1min 5min
2 Ind. Dim. 1 2 3 4
1
Easy setting Back End
Room 1 Division 1
Address
Page 1 Page 2 Page 3 Meeting
Room 2
Sales
Division 2
Press "OK".
Quit setting and
Press "Set". 1 Select the timer.
2F
Accounting
Room
All lights
2 Press "Sel.".
3F
Press "End" . Press "Yes" . Returned to the normal screen. Please exit by pressing "End", and follow the instructions on the screen.
※ In "SETTING mode" the screen is returned to the normal screen without any operation in 10 minutes.
In this case, only settings you pressed "Yes" can be saved.
The programmed switch will be displayed.
12 13
※Please set Pattern / Group Control data with Wireless
Address Setting / Pattern / Group Switch
Easy setting
Programming Unit(WRT9600-8[Optional])etc. Detailed setting
Steps to the Address Setting / Pattern / Group Switch Address No. 1-127 can be set.
Address
Easy setting
Setting SETTING
Select Page
Group
Enter Password
Button mode
Detailed
Address Select Page Example: Set "Group 1" to "Switch 7".
setting
When you set the timer ... When you do not set the timer ...
Address Back End Address: Esc OK 3 Press "OK".
Switch 1 Switch 5 ※Settings are saved.
Ind.0-1 Ind.1-1 P 1 Clear 3
Switch 2 Switch 6 Address: Esc OK Switch Timer Esc Sel.
Ind.0-2 Ind.1-2 Ind. Dim. 1 2 3 4
Timer
Without Timer
Switch 3 Switch 7
P G 5 G 1 Clear - Set 2
Ind.0-3 Address Unset 26 7 8
OFF-Delay
Switch 4 Switch 8 Ind. Dim. 1 2 3 4 30sec 1min 5min
9 0
Ind.0-4 Address Unset 1 ON-Timer
P G 5 6 7 8 30sec 1min 5min
Press the switch you want to set. ① Press "P".
9 0 1hr 2hr 1
② Press "1".
③ Press "OK". Press "Set". 1 Select the timer.
※ If you change the function, 2 Press "Sel.".
the address that has already
been entered is cleared. Address: Esc OK ※Settings will not be saved
※ If you want to change the address Timer at this time.
that has already been G 1 Clear
ON-Timer
Set
5min
entered, press "Clear" and
enter address. The timer you selected Ind. Dim. 1 2 3 4 Press "OK".
is displayed.
P G 5 6 7 8
9 0
Please exit by pressing "End", and follow the instructions on the screen.
The programmed switch will be displayed.
14 15
Address Setting / Dimmer Switch ※After making the Dimmer Switch shape(refer to P.20), Easy setting
please set the address. Detailed setting
Steps to the Address Setting / Dimmer Switch Address No.1-127 can be set.
Easy setting
Address
Select Page Dimmer(Group)
Setting SETTING Enter Password
Button mode
Detailed
Example: Set " Group 1" to the switch. For dimming : Esc OK
Switch 5
End For dimming : Esc OK
② Press Load Channel "6".
Dimmer
For Dimming
Ind. 1-1 Ind. 6−1 Clear
5 ③ Press "-".
Address Unset
Switch 6 Example: Set " Dimmer 16 " to the switch. For dimming : Esc OK
Ind. 6-1
Ind. 1-1 Ind. 6−1 Clear - Set ③ Press "-". Ind. 6−1 Clear
Timer
-
なし Set
Without Timer
2 Ind. 6−1 Clear
Timer
OFF-Delay
30sec Set
Switch 6
Ind. 1-2 Ind. Dim. 1 2 3 4 ④ Press Load Number "1". Ind. Dim. 1 2 3 4
OFF-Delay
30sec 1min 5min Ind. Dim. 1 2 3 4
For ON / OFF
※ If you change the function, ON-Timer
Switch 7
Address Unset
G1 1 G 5 6 7 8 the address that has already G 5 6 7 8 30sec
1 1min 5min G 5 6 7 8
Switch 8
4 been entered is cleared. 9 0 − 1hr 2hr 9 0 −
9 0 − ※ If you want to change the
Switch1 P1
2 address that has already been Press "Set". 1 Select the timer. Press "OK".
entered, press "Clear" and
Press the switch you want 3 enter address.
to set(For ON / OFF). 2 Press "Sel.". The timer you
※Settings will not be saved selected is
at this time. displayed.
When you set the timer ...
When you do not set the timer ... Please exit by pressing "End", and follow the instructions on the screen.
5 Press "OK". The programmed switch will be displayed.
※ Settings are saved.
16 17
Setting Switch Name Setting Page Name
Easy setting Easy setting
Detailed setting Detailed setting
Up to 20 characters can be displayed for each switch. For example, " EXIT ". Up to 10 characters can be displayed for tab of each page.
For example, " 1F "," 2F ", and " 3F " etc..
etc.
Steps to the Setting Switch Name Steps to the Setting Page Name
Switch Name Page Name
Easy setting Select Page Easy setting Select Page
Setting SETTING Setting SETTING
Enter Password Enter Password
Button mode Button mode Page
Detailed Switch Detailed
Select Page Select Page
setting name setting name
Tab
Name of Switch Back End Name of Switch Esc OK Name of Page Esc OK
Switch1 Switch5
(Unset) (Unset)
EXIT
2 1F
2
Switch2 Switch6
●Indication of
会議室1 営業部1
AB
(Unset) (Unset) ABC DEF GHI JKL Clr ABC DEF GHI JKL Clr
tab characters
Switch3 Switch7
(Unset) (Unset) MNO PQRS TUV WXYZ MNO PQRS TUV WXYZ
1 1 会議室2 営業部2
Switch4 Switch8
(Unset) (Unset) - . @ Char CR - . @ Char CR
総務部 資料室
Press the switch you want to set. ① Enter the name. ① Enter the name.
② Press "OK". ② Press "OK". 経理部 1F全消灯
ABC DEF GHI JKL Clr ABC DEF GHI JKL Clr
MNO PQRS TUV WXYZ AaBb Sign MNO PQRS TUV WXYZ
Press "Char.". Select the input mode. It changes into the input mode
you selected.
18 19
Setting Switch Type Detailed setting
Steps to the Setting Switch Type You can make a large switch by merging two or more switches.
Setting SETTING Detailed You can make a Dimmer Switch by selecting "Dim." in Switch Type.
Enter Password Switch Type Select Page
Button mode setting
2
1 Switch4 Switch8 Color
YES NO
Switch8 Color
Switch6 Mer
Switch1
Switch6 Mer
4
Switch2 Switch6 Mer
② Press "Mer". ① Select Dimmer Switch. ③ Select the switch you Press "OK".
※ It is impossible to merge switches to shape that is not a rectangle.
want to divide. ※Contents set to "Switch1"
Example
② Press "No Dim". are copied to "Switch2"-
④ Press "Div". "Switch4".
Type of Switch Esc OK Type of Switch Esc OK Type of Switch Esc OK Type of Switch Esc OK
Switch3 Switch7 Dim. Possible Switch7 Switch7 Dim. Switch3 Switch7 Dim. Impossible Switch7 Switch7 Dim.
Switch4 Switch8 Color to merge Switch8 Switch8 Color Switch4 Switch8 Color to merge Switch8 Switch8 Color
Type of Switch Esc OK Type of Switch Esc OK Switch1 Switch5 Div Switch1 Switch5 Div
1 YES NO
Switch4 Switch8 Color
2 Switch1 Switch8 Color
Press the switch you want to ① "Yellow","Blue", and 1
1 change color. "Default Color" are displayed
① Select four switches in Press "OK". sequentially whenever you push
Press "Yes". ※ You can also set for two or more switches
the vertical direction.
at the same time. "Color" and please select the color
② Press "Dim". you want.
② Press "OK".
Please exit by pressing "End", and follow the instructions on the screen. The programmed switch will be displayed.
20 21
Setting Sound and Screen Detailed setting
Screen setting
Beep setting
Start Screen Esc OK
Page 1 Page 2
When you selected
"Invalid" in Display
2
Sound and Screen Back End Beep Esc OK
setting (P.27)
Page 3
1
Former
Beep Screen Coloration 2 "Former screen" is the
screen
OFF
screen displayed before 1 Select the page you want.
Brightness Character Link
position control the screen light was turned
ON
off automatically. 2 Press "OK".
Auto-off State
Sound and Screen Back End
indication 1
Beep Screen Coloration
Press "Beep". ① Select"OFF" or "ON".
Character
② Press "OK". Brightness
position
Link control
After pressed
Auto-off State ① or ② .
Indication
Press "Screen".
Start Screen Esc OK
2
①② Press "Chg".
③ Press "OK".
Please exit by pressing "End", and follow the instructions on the screen.
22 23
Setting Sound and Screen Detailed setting
Steps to the
Setting SETTING Detailed Sound
Setting Sound Enter Password
Button mode setting Screen
and Screen
You can match the switch and the surrounding installed by setting
the coloration of the screen background, and the brightness You can select the position of characters for switch name.
of the screen.
Dark Bright
Auto-off State
indication
Please exit by pressing "End", and follow the instructions on the screen.
24 25
Setting Sound and Screen Detailed setting
4 ② Press "Chg", and input the The operation of switches will be Ind. 63−4 Chg OFF ctrl 2
Screen
locking
Effective Page 1
address. invalidated. 1 setting Page1 Display Non-display
Sales
④ Press "OK".
Meeting Page 2 Display Non-display
1F
Room 1 Division 1
The example of Display setting 1
63-3 Meeting Sales
Room 2The screen isDivision
Page 3 Display Non-display
locked. 2
2F
Sales
LegalIt is impossible to operate.
Meeting
1F
Reference Room 1 Division 1
can not
1 Select "Display" or "Non-
2F
Accounting All lights Legal
3F
Reference
3F
the screen is unlocked.) The external switch is ON. Division OFF
2 Press "Sel".
case 1
1F
Conference
room 1
If Screen locking addresses are included in "All OFF" Pattern control program, 63-4
2F
you can turn off all the lights and lock the screen at the same time when you Conference
room 2
press the "All OFF" Pattern switch.
3F
The external switch is OFF.
case 2
If Screen locking addresses are set to Program Timer Unit (WRT3540K-8 etc.), the case
screen can be locked at the time you want. When one big conference room is divided to two small canference
room, by installing this product next to each entrance and set
"Effective", it will avoid controlling the entire room.
Please exit by pressing "End", and follow the instructions on the screen.
26 27
Setting Sound and Screen Detailed setting
Auto-off State
indication 1min
Without character With character
① Select the auto-off time
Press "Auto-off". you want to set.
Meeting Meeting
OFF
② Press "OK". Individual or Group:OFF Room 1 Individual or Group:OFF Room 1
Meeting Meeting
Individual or Group:ON Individual or Group:ON
ON
Room 1 Room 1
Please exit by pressing "End", and follow the instructions on the screen. All lights All lights
Pattern
Pattern:Disagreement OFF Pattern:Disagreement OFF
Pattern
Pattern:Agreement OFF Pattern:Agreement OFF
28 29
※ The setting data of one LCD Appellation Touch Switch
Read / Write setting data with SD Memory Card can be written in one SD Memory Card. Detailed setting
You can back up and edit setting data on your PC, by using SD Memory Card How to insert or remove SD Memory Card
[Optional].
To write and read the data safely, please follow the steps when inserting and SD Memory Card Slot is located on the side of the LCD Touch Panel Block.
removing SD Memory Card. After you remove LCD Touch Panel Block from Power Block,
please insert or remove SD Memory Card.
Yes No
SD Memory Card
●Panasonic made SD (HC) Memory Card [Optional]
After the screen light is turned off automatically, 4GB or less.
you can insert or remove SD Memory Card. (BACK) ※Please note that all other data processing operation in the
SD Memory Card can not be guaranteed.
※ When LCD Touch Panel Block is set into Power Block
after SD Memory Card is inserted or removed, SD Memory Card Slot
the screen will restart automatically.
30 31
Read / Write setting data with SD Memory Card Detailed setting
SD Write SD Read SD IN / OUT SD Write SD Read SD IN / OUT Read data from SD card.
Write the setting data The setting data is overwritten.
to the SD Memory Card? Are you sure?
Dialog box Password Maintainance Dialog box Password Maintainance
Yes No
Yes No
Press "SD Write". Press "Yes". Press "SD Read". Press "Yes".
Close Close
32 33
Read / Write setting data with SD Memory Card Detailed setting
File format of reading and writing How to edit the setting data written to SD Memory Card
R
■Data Format :CSV file The setting data written to SD Memory Card can be imported into Excel by following
R R
■Data Configuration :Refer to the following chart. this operation. (For Microsoft Excel 2003 version )
■The setting data that can be edited :All data except addresses for "Link control". (P.26 - P.27)
R R R
■How to edit the setting data :Possible to edit by text editors,Microsoft Office Excel etc..
(※ You need to edit and save the data as "Text".(P.35 - P.37))
N ote When you write the setting data to SD Memory Card the file name will be named
"wrt9261.csv" automatically.
Please do not change this file name. If changed, it will not work. 4 Select delimiter "Comma"
and click "Next".
1 Open
R
Page 2 Settings
5 Select all of the data portion in the
preview.
Cell to follow the column data format.
Page Name Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Switch 7 Switch 8 Select column data format "Text" and
Setting settings settings settings settings settings settings settings settings then click "Finish".
7 Excel
R
sheet displays the contents
Start Character Link Dialog State of SD Memor y Card in Excel
Beep Coloration Brightness Auto-Off Password
Screen Position Control Box Indication Spreadsheet Format.
3 Click "Next". Select “Text”.
34 35
Read / Write setting data with SD Memory Card Detailed setting
The setting data that can be read and written(Factory default settings)
SDカードを用いて読書きするファイル書式 Heading Settings Guidelines for application setting Initial
Setting
Initial Set the brightness 0:Level1 1:Level2 2:Level3
Heading Settings Guidelines for application setting Brightness 2
Setting of the screen (Higher the level, brighter the number)
Horizontal Switch
Name of Page Page name data Within 10 characters Blank
Character Position Name and character 0:Left 1:Center 2:Right 1
position setup
Name of Switch Data Name Switch
Within 10 characters Blank
(Before Changing Line) (First half)
Backlight Automatic Backlight turn off Timer 0:10sec 1:30sec 2:1min 0
Name of Switch Data Name Switch
Within 10 characters Blank
(After Changing Line) (Second half)
The screen lock
Please fill in the two-digit number. Screen Locking 0:Invalid 1:Effective 0
Enable / disable setting:
Of vertical coupling: 10th of
Horizontal bond number: 1 digit Screen lock feature
Shape of switch Combining data switch (Example) When you join one vertical column, 11 ※This section is not set.
Address of Screen To use Blank
enter "41" type. The instrument can be set only on the screen.
Locking Virtual terminal address
※ If you want to join, please enter "00" from the
second switch. 0:Page1 1:Page2 2:Page3
Screen lock setup
Separate switch / Page of Screen Locking 3:Page1 and 2 4:Page1 and 3 7
Type of Switch 0:Individual 1:Dimmer 0 page
Dimmer switch 5:Page2 and 3 6:All 7:None
Color of Switch Switch display color 0:Default 1:Yellow 2:Blue 0 Display features
Display 0:Invalid 1:Effective 0
Address Type 0:Individual 1:Group Enable / Disable
Address data type 0
of Switch 2:Pattern 3:Dimmer
Display features
※This section is not set.
Enter a number. However, unset address is Address of Display to use Blank
The instrument can be set only on the screen.
Address of Switch Contacts represented by the blank. Blank Virtual terminal address
※ If the individual, enter "Channel ""-"" load number"
0:Page1 1:Page2 2:Page3
0:ON-Timer 30sec 1:ON-Timer 1min Setting displayed address 3:Page1 and 2 4:Page1 and 3
ON Control 6
2:ON-Timer 5min 3:ON-Timer 1hr when turned on 5:Page2 and 3 6:All 7:None
Timer Set of Switch Timer data 8
4:ON-Timer 2hr 5:Off -Delay 30sec
6:Off -Delay 1min 7:Off -Delay 5min 0:Page1 1:Page2 2:Page3
Setting displayed address
8:None OFF Control 3:Page1 and 2 4:Page1 and 3 6
when turned off
Beep Operation sound 0:OFF 1:ON 1 5:Page2 and 3 6:All 7:None
36 37
System Detailed setting
1F
Room 1 Division 1
Division OFF
SD Write SD Read SD IN / OUT Dialog box when switch is operated. 2 ※When you forget your password and want to
Dialog box Password Maintainance Effective initialize your password without changing the
settings, please contact our nearest sales office.
Invalid 1
Please exit by pressing "End", and follow the instructions on the screen.
38 39
Maintenance Detailed setting CLEAN mode / Cleaning Instructions
Steps to the Maintenance The screen can be locked temporarily (5 minutes) for cleaning purposes.
1F
Room 1 Division 1
2F
Legal Reference CLEAN mode SETTING
Division Room
mode
Maintainance Esc OK
Accounting All lights
3F
Division OFF
Initiali
-zation Are you sure
Will you return to
Screen
adjustment
the factory default settings? to initialize it?
Press "CLEAN mode".
Yes No Yes No
Version
You can adjust the touching point when it is not pointing properly.
When this screen is displayed,you can clean the screen.
Screen adjustment
1F
シーン
OFF
生産管理部 生産管理部
シーン
生産管理部
2F
生産管理部
The screen does not respond
Please correct with the stylus pen made of plastic. for 300 seconds.
The screen does not respond
生産管理部 生産管理部
シーン
When you correct with your finger, you may not be able to correct. *Compulse
生産管理部 return
生産管理部
ON
for 300 seconds. 生産管理部
Press ○ button
生産管理部
for more than five seconds.
シーン
生産管理部 生産管理部
1+
ON
Maintainance Esc OK
+
3 Maintainance Esc OK
*Compulse return
Initiali
-zation
Screen Adjustment Initiali
-zation
Press ○ button
for more than five seconds.
Screen
adjustment
+ 5 Screen
adjustment
Touch [+] to start.
Version 2+ +
4 Version
Press and hold "Setting Button" for 5 seconds
"CLEAN mode" return to the normal screen
automatically after 300 seconds. or more. Then, it is possible to return to the
Press "Screen adjustment". Press the center After correction, the screen will be normal screen.
of "+" from ① back to "Maintenance" automatically.
to ⑤ in order. Cleaning Instructions
Note
Touch panel correction failed.
Do not use sharp tipped pens Please wipe the screen and the body with
Please start over again,
or pencils. when failed. OK the cloth that is soaked in the neutral detergent
This may cause damages to the and then squeezed.
screen. Discoloration and the breakdown might occur if
you use the detergents other than the neutral
Please exit by pressing "End", and follow the instructions on the screen. detergent. Benzine
Thinner
Insect
killer
Alkaline detergent
Acid detergent
40 41
Troubleshooting Ratings and Specifications
If the following messages appear, please confirm the mode and
take corrective action accordingly. Ratings
Error Message Cause Corrective Action Rated Input Voltage
Not for U.S.A For U.S.A
24 V AC (for Remote Control Transformer only) 24 V AC
●FULL-2WAY signal wire is broken. Please check the connection Rated Current Consumption 200 mA
FULL-2WAY of FULL-2WAY signal wire. Rated Input Signal Voltage ±24 V
Communication error ●FULL-2WAY signal wire is not connected.
occurred.
Only setting mode can be operated.
Please check the power of Rated Signal Current Consumption 15 mA
●Transmission unit is powered off.
the Transmission unit.
Specifications
Signal Wiring Method 2-Wire Non Polarized Wiring Method
System error occurred. 01
It is impossible Signal Transmission Method Cyclic Time Division Multiplex Transmission Method
to operate right now.
Please contact with the manager
of the system. Transmission Frequency 10 kHz ± 1 kHz
●Malfunction is found in hardware. Please replace the unit. Odd Number parity check, checksum
Error Detection Method
It is impossible Applicable Transmission Unit WRT2050 Series , WRT2040 Series ,WRT2000 Series
to operate right now.
Please contact with the manager Not for U.S.A For U.S.A
of the system. Applicable Remote Control
WR2301-811,WR2311-821, WR2311-851
transformer
●Malfunction is found in the touch panel. Please replace the unit. Up to 24 Individual, Group and Pattern switches can be set in total.
System error occurred. 03
※ Please set Pattern / Group control data separately when you use for
It is impossible ●The touch panel is kept pressed Please remove the one Number of switches can be controlled Pattern / Group switches.
to operate right now.
Please contact with the manager with something. keeping pressing Up to 6 Dimmer switches can be set in total.
of the system.
※ The size of Dimmer switch is four times the minimum size of Individual or
※Other error messages during work are described in P.32, P.33,and P.40 . Pattern or Group switch.
Solid wire of 0.65 mm -1.6 mm in diameter
(Signal)
Stranded wire of 0.5 mm 2 - 2.0 mm 2 in section
If the unit is not functioning properly, before your contact manufacturer please check the following. Applicable wire gauge
Solid wire of 0.9 mm -1.6 mm in diameter
(24 V AC)
States Check points Corrective Action Stranded wire of 0.75 mm 2 - 2.0 mm 2 in section
0.2(4.9) MAX 0.2(4.9) MAX
Is the screen light auto-off ? Please touch the screen.
0.3(7.6)MAX
(Ф7.6)MAX
(Ф3.7)MIN
(3.7)MIN
The screen is Crimp Terminal Application
Is the fuse for the (remote control) transformer Please replace the fuse.
Ф0.15
0.15
Ф0.3
not displayed.
blown ? [inch(mm)]
Is the fuse for the (remote control) tansformer Please check the connected position. AC 24 V input wire length φ1.2 mm - φ1.6 mm(1.25 mm2 -2.0 mm2): 100m φ0.9 mm(0.75 mm2): 50m
connected ? Refer to P.6
COSMO Module Plates applicable to switches (WTC9222-8, etc.)[Optional]
Please select "ON" in Beep setting. Plate applied
It does not beep. Is "OFF" selected in Beep setting.
Refer to P.22 GLACIER Series Plates applicable to switches [Optional]
The screen is not Did you set the brightness at the side of Please set the brightness at the side of "Bright". Operating temperature 0 ℃ - + 40 ℃
bright enough "Dark" ? Refer to P.24
LCD life (When the backlight is lighting) 20,000 hours (reference)
It is no response when The gap might be generated between the Please adjust the screen.
screen is touched. operation point and the display position. Refer to P.40 SD Memory Card SD Memory Card (4GB or less) [Optional]
42 43