0% found this document useful (0 votes)
256 views2 pages

Manhole 2

This document contains calculations for components of a sewerage system. It lists manholes, population density, cumulative population, design flow, pipe diameter, gradients, velocity, capacity, length, fall, ground level, invert level, depth and manhole type. Pipe sizing is calculated based on design flow rates between manholes accounting for population served along the sewer line. Manhole inverts, depths, and types are specified. The sewerage system routes flow from manholes through pipes of specified length, diameter, and fall to a pump sump and aeration tank.

Uploaded by

api-26699613
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
256 views2 pages

Manhole 2

This document contains calculations for components of a sewerage system. It lists manholes, population density, cumulative population, design flow, pipe diameter, gradients, velocity, capacity, length, fall, ground level, invert level, depth and manhole type. Pipe sizing is calculated based on design flow rates between manholes accounting for population served along the sewer line. Manhole inverts, depths, and types are specified. The sewerage system routes flow from manholes through pipes of specified length, diameter, and fall to a pump sump and aeration tank.

Uploaded by

api-26699613
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

CALCULATION FOR THE COMPONETS OF THE SEWERAGE SYSTEM

Project Title : NICHIA (MALAYSIA) SDN. BHD. Sheet No : 1/1

Date : 12TH MAY 1997


Job No : SM/NM/SW/001
Designed By : H. P. LOW

Manhole Unit Density Population Cummu Cummu Design Cummu Diameter Gradients Velocity Capacity Length Fall G.L. I.L. Depth Manhole
to (Persons/ on line -lative -lative Flow at -lative (mm) (m/s) (l/s) (m) (m) (m) Type
Manhole Unit Population Population DWF Design
(Person) Equivalant (m³/min) Flow
P.E (0.3) (m³/min)
MH-II-7 29.1 27.60 1.5 HEAVY

2 3 6 6 1.8 0 0 225 1 : 150 1.2 50 24 0.16

MH-II-8 29.1 27.44 1.66 HEAVY

- - - 6 1.8 0 0 225 1 : 150 1.2 50 15 0.10

MH-II-9 29.1 27.22 1.88 HEAVY

17 3 51 57 17.1 0 0.01 225 1 : 150 1.2 50 22 0.15

MH-II-10 29.1 27.03 2.07 HEAVY

TO 4 3 12 69 20.7 0 0.01 225 1 : 150 1.2 50 28 0.19

MH-II-6 29.57 26.88 2.69 HEAVY

MH-II-1 29.1 27.60 1.50 HEAVY

6 3 18 18 5.4 0 0 225 1 : 150 1.2 50 22 0.15

MH-II-2 29.1 27.45 1.65 HEAVY

- - - 18 5.4 0 0 225 1 : 150 1.2 50 11 0.07

MH-II-3 29.1 27.38 1.72 HEAVY

26 3 78 96 28.8 0 0.02 225 1 : 150 1.2 50 8 0.05

MH-II-4 29.57 27.33 2.24 HEAVY

- - - 96 28.8 0 0.02 225 1 : 150 1.2 50 17 0.11

MH-II-5 29.57 27.22 2.35 HEAVY

- - - 96 28.8 0 0.02 225 1 : 150 1.2 50 17 0.11

MH-II-6 29.57 26.88 2.69 HEAVY

TO 23 3 69 165 49.5 0 0.03 225 1 : 150 1.2 50 17 0.11

PUMP SUMP 29.71 26.77 2.94 HEAVY

TO

50 PE AERATION TANK
: 12TH MAY 1997