General Construction Notes: Typical Connection Detail of Masonry Wall
General Construction Notes: Typical Connection Detail of Masonry Wall
General Construction Notes: Typical Connection Detail of Masonry Wall
(DOWEL)
400
CHB WALL
3. IF THE BEAM REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FROM THE BAR TO THE FARTHER FACE OF THE
1-Ø16 VERT. BARS 1. WHERE A CONSTRUCTION JOINT IS TO BE MADE, THE SURFACE OF CONCRETE
WALL IS NOT LESS THAN 25mm. EMBEDMENT LENGTH SHALL BE SHOWN IN A TABLE 'A' FOR TENSION BARS AND TABLE 'B' FOR SIZE AND SPACING
OF HOR. & VERT. BARS SHALL BE CLEANED AND ALL LAITANCE AND STANDING WATER REMOVED SHEAR
FOR COMPRESSION BARS UNLESS UNLESS SPECIFIED IN PLAN. TOP BARS AND SHALL NOT BE SPLICED WITHIN THE KEY SHALL BE PROVIDE AT THE JOINT.
FOR SIZE AND SPACING SEE CONSTRUCTION NOTES.
COLUMN OR TWO STIRRUPS SHALL BE PROVED AT ALL SPLICES. OF HOR. & VERT. BARS
SEE CONSTRUCTION NOTES. MAIN REINFORCEMENTS TO BE
4. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USED 25mm BAR SEPARATORS SPACED AT 1.0M ON CONTINUOUS (TOP & BOTT. BARS)
ON CENTER ON NO CASE SHALL THERE BE THAN TWO (2) SEPARATORS BETWEEN LAYERS OF BARS CHB WALL
MAIN REINFORCEMENTS WHERE JOINTS IS AT POINT OF
5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS OR STEEL SHAPES SHALL BE AS SHOWN IN FIGURE B-2 TO BE CONTINUOUS STRESS, PROVIDE SHEAR RODS
WITH ENGINEERS APPROVAL
UNLESS ELSEWHERE. CORNER WALL OPENING OR END WALL
Ø 10 X 1000 LONG
@ 300 O.C.
300 BAR 300 BAR
50
(MIN.) (MIN.)
40
D/3
MAIN REINFORCEMENT MAIN REINFORCEMENT
D/3
t/3 t/3
D
t/3
t OR 1/4 D
t OR 1/4 D
t
SLEEVES FOR UTILITY
D/3
SLEEVES FOR UTILITY
t
(DOWEL)
OTHERWISE PERMITTED BY THE STRUCTURAL ENGINEER.
400
FOR SIZE AND SPACING 2. AS SHOWN IN THE DESIGN DRAWINGS OR
6. WHEN A BEAM CROSSES A GIRDER , REST BEAM ON TOP OF GIRDER BARS, BEAM REINFORCING BARS SHALL BE OF HOR. & VERT. BARS PERMITTED BY THE STRUCTURAL ENGINEER.
SEE CONSTRUCTION NOTES. 400
SYMMETRICAL ABOUT THE CENTER LINE WHENEVER POSSIBLE. 3. TIES & CLOSE STIRRUPS MUST BE AT 135.
(DOWEL)
7. GENERALLY, NO SPLICES SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESSES OCCUR, SPLICES
WHERE SO PERMITTED SHALL BE INDICATED IN TABLE 'A' AND 'B'. WELDED SPLICES SHALL DEVELOP IN TENSION AT
INTERSECTION WALL INTERSECTING R.C. COLUMN OR WALL
LEAST 125% OF THE SPLICED YIELD STRENGTH OF THE BAR NOT MORE THAN 50% OF THE BARS AT ANY ONE SECTION 180 DEG. HOOKS
Dbar
IS ALLOWED TO BE SPLICED THEREIN.
TYPICAL CONNECTION DETAIL OF MASONRY WALL
D+12db
135 DEG. HOOKS
4db OR 65mm LE
NOTES ON CONCRETE HOLLOW BLOCKS WALLS
6d
D
90 DEG. HOOKS b
1. UNLESS OTHERWISE SHOWN IN PLANS ALL CONCRETE HOLLOW BLOCKS AND CERAMIC BLOCKS SHALL BE REINFORCED Dbar
DOWEL BARS TO
AS SHOWN IN THE SCHEDULE OF CONCRETE HOLLOW BLOCKS AND CERAMIC BLOCK REINFORCEMENT. MATCH VERT. BARS
FLR. SLAB OR BEAM
2. PROVIDE 150mm X 300mm STIFFENER COLUMN REINFORCED WITH 4-12mmØ WITH 10mmØ TIES AT 150mm ON CENTER L1
12db
(DOWEL)
WHERE CONCRETE HOLLOW BLOCK TERMINATES AND AT EVERY 3.0M LENGTH OF CONCRETE HOLLOW BLOCK
1. ALL JOINTS AND CELLS
400
CONTAINING REINFORCING
BARS SHALL BE FILLED
WITH CONCRETE GROUT. MAIN BAR END HOOKS STIRRUP AND THE TIE HOOKS
NOTES ON CONCRETE HOLLOW BLOCKS WALLS REINFORCEMENTS 2. FOR REINFORCEMENTS SEE (ALL GRADES) (ALL GRADES)
HORIZONTAL LAPPED A. MINIMUM LAPS AT SPLICE= 0.25 M 1- Ø16 CONT. HOR. BARS 60 75 125 150 10 mmØ 40 125 85 100
10 mmØ
400
REINFORCEMENT SHALL BE PROVIDED TYP. SECTION OF MASONRY 32 mmØ 150 335 230 405
25 mmØ 150 200 230 450
200 mm 12mm Ø EVERY 3RD LEVEL 10mm Ø @ 600mm O.C
PARTITION REINFORCEMENTS 28 mmØ 240 300 350 550
REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: DRAFTED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
MICHELLE A. COLBONGAN
REGION II GENERAL CONSTRUCTION NOTES ENGINEERING ASSISTANT
BASIC INFRASTRUCTURE PROGRAM (BIP)- MULTI- PURPOSE
ISABELA FOURTH BUILDINGS/FACILITIES TO SUPPORT SOCIAL SERVICES-
CONSTRUCTION OF MULTI-PURPOSE BUILDING, BARANGAY PREPARED: MARLON S. LUCAS ANACLETO SANTOS A. BUMAGAT JR. EMMANUEL A. MANSIBANG EVELYN C. COSTALES, Ph.D S 10
DISTRICT ENGINEERING OFFICE VILLA SANCHEZ, SAN GUILLERMO, ISABELA
BRGY. VILLA SANCHEZ, SAN GUILLERMO, ISABELA DONNE JOLLEE C. DUMELOD ENGINEER II CHIEF, PLANNING AND DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER 2 7 20
QUEZON, SAN ISIDRO, ISABELA ENGINEER II DATE: DATE: DATE: DATE: