En 5 4 304 95000
En 5 4 304 95000
En 5 4 304 95000
Technical features
Medium: Orifice: Ambient/Media temperature: Material:
For neutral gaseous and liquid 1,5 ... 12 mm NBR: Housing: brass 2.0401 (Ms 58)
fluids (with contaminated fluids, Port size: -25 ... +80°C (-13 ... +176°F) Seals: NBR
upstream installation of a dirt G1/4, G1/2, 1/4 NPT FPM: other see option selector
trap is recommended) Flow direction: -10...+120°C (+14 ... +248°F) Inner parts: stainless steel 1.4104
Operation: Fixed Water +95°C (+203°F) (430 F), brass 2.0401 (Ms 58)
Direct solenoid operated Mounting position: EDPM:
poppet valve Optional, preferably -40... +140°C (-40 ... +284°F) Further versions
Operating pressure: with solenoid on top FFPM: Operating pressure to 50 bar;
0 ... 40 bar (0 ... 580 psi) -10....+140°C (+14 ... +284°F) Seat seals FPM, EPDM, FFPM,
PTFE: PTFE, Rubin;
-50....+180°C (-58 ... +356°F) Assembled oil and grease-free
Depending on solenoid system
and seal materials. Flow conversion:
Air supply must be dry enough Cv US Gallon/min (water) =
to avoid ice formation at l/min (air) x 0,001
temperatures below +2°C Kv m³/h (water) =
(+35°F). l/min (air) x 0,000906
Technical data
Housing: Brass, Seals: NBR -25 ... +80°C (-13 ... +176°F)
Symbol Port size Orifice Flow Operating pressure Weight Dimension Solenoid Model *1)
(mm) (l/min) (bar) (psi) (kg) (lbs) No. group
G1/4 1,5 70 0 ... 40 0 ... 580 0,21 0.46 1 13B 9500100
G1/4 2 120 0 ... 35 0 ... 507 0,21 0.46 1 13B 9500200
1/4 NPT 2 120 0 ... 35 0 ... 507 0,21 0.46 1 13B 9503200
G1/4 3 200 0 ... 10 0 ... 145 0,21 0.46 1 13C 9500300
12 2 10 12 2 10 1/4 NPT 3 200 0 ... 10 0 ... 145 0,21 0.46 1 13C 9503300
G1/4 4 350 0 ... 12 0 ... 174 0,21 0.46 1 13D 9500400
1 1 1/4 NPT 4 350 0 ... 12 0 ... 174 0,21 0.46 1 13D 9503400
G1/4 4 350 0 ... 14 0 ... 217 0,21 0.46 2 16D 9501400
12 2 10 12 2 10
G1/4 6 550 0 ... 5 0 ... 72 0,25 0.55 2 16D 9501600
1/4 NPT 6 550 0 ... 5 0 ... 72 0,25 0.55 2 16D 9504600
1 1 G1/2 12 1700 0 ... 1 0 ... 14 0,8 1.76 4 16D 9501700
12
12 2210 12 2 10
2 G1/4 2 100 0 ... 20 0 ... 290 0,21 0.46 3 13B 9502210
10 12 10
G1/4 3 160 0 ... 10 0 ... 145 0,21 0.46 3 13B 9502310
11 1
1
12 *1) When
2 10 12 ordering
2 10please indicate solenoid, voltage and current type (frequency).
1 1
12 2 10 12 2 10
Our policy is one of continued research and development. We therefore reserve the right to amend, 06/22
without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.01
1 1
Option selector 950x⭑x⭑.⭑⭑⭑⭑.⭑⭑⭑⭑
Orifice (mm) Substitute Voltage Substitute
1,5 1 24 V d.c. 02400
2 2 230 V a.c. 23050
3 3 Solenoid Substitute
4 4 See solenoid table
6 6
12 7
Material seat seal Substitute
NBR 0
EDPM 1
FPM 2
PTFE only orifice 1,5 ... 4 NC 3
FFPM 4
Rubin only orifice 2 ... 3 NC 5
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.02 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Solenoids group 13B, standard voltages
Power Rated current Protection Ex-Protection Temperature Electrical Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
IP/NEMA Media
24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
8,0 — 331 — IP65 — -25 ... +60 Connector 1 1 0246
(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)
6,9 - 289 - IP66 II 2G Ex mb IIC T3 Gb -20 ... +60 Cable length 3 m 5 4 0292
II 2D Ex mb IIIC T135°C Db
3,9 - 162 - IP66 II 2G Ex eb mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 6 4 4210
(with cable T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80
- 5,3 - 23 IP66 II 2G Ex eb mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 6 7 4211
(with cable T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80
3,9 - 162 - IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 1/2 NPT *1) 7 20 4610
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80
- 5,3 - 23 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 1/2 NPT *1) 7 21 4611
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80
3,9 - 162 - IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 7 20 4612
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80
— 5,3 — 23 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 7 21 4613
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80
5,5 — 228 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3722
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
— 5,9 — 26 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3723
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals
Model Approvals Datasheet
ATEX IECEx FM
029x KEMA 02 ATEX 1347 X IECEx DEK 13.0014X — en 7.1.505
321x, 381x EC-Declaration of Conformity — — en 7.1.570
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585
Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.03
Solenoids group 13C, standard voltages
Power Rated current Protection Ex-Protection Temperature Electrical Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
IP/NEMA Media
24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
12,1 — 504 — IP65 — -25 ... +60 Connector 1 1 0200
(with Media: DIN EN
connector) +80 max. 175301-803,
form A *1)
— 11,3 — 49 IP65 — -25 ... +60 Connector 2 6 3204
(with con- Media: DIN EN
nector) +80 max. 175301-803,
form A *1)
12,1 — 504 — IP65 II 3G Ex nA IIC T4 Gc -20 ... +60 Special 1 1 3217
(with II 3D Ex tc IIIB T130°C Dc connector
connector) DIN EN 175301-803
Form A
10,7 — 446 — IP66 II 2G Ex mb IIC T3 Gb -20 ... +40 Cable length 3 m 5 4 0290
II 2D Ex mb IIIC T155°C Db
8,9 — 369 — IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +65 M20 x 1,5 *1) 6 4 4220
(with cable T5: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ... +65
— 10,0 — 43 IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +65 M20 x 1,5 *1) 6 7 4221
(with cable T5: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ... +65
8,9 — 369 — IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 1/2 NPT *1) 7 20 4620
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70
— 10,0 — 43 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 1/2 NPT *1) 7 21 4621
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70
8,9 — 369 — IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 M20 x 1,5 *1) 7 20 4622
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70
— 10,0 — 43 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 M20 x 1,5 *1) 7 21 4623
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70
8,9 — 369 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3724
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
— 9,5 — 41 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3725
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals
Model Approvals Datasheet
ATEX IECEx FM
029x KEMA 02 ATEX 1347 X IECEx DEK 13.0014X — en 7.1.505
321x, 381x EC-Declaration of Conformity — — en 7.1.570
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.04 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Solenoids group 13D, standard voltages
Power Rated current Protection Ex-Protection Temperature Electrical Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
IP/NEMA Media
24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
16,9 — 703 — IP65 — -25 ... +60 Connector 3 1 0700
(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)
11,4 — 475 — IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 4 4230
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
— 15,2 — 66 IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 7 4231
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 20 4630
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
— 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 21 4631
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 20 4632
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
— 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 21 4633
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
13,6 — 567 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3726
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
— 15,7 — 68 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3727
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals
Model Approvals Datasheet
ATEX IECEx FM
321x, 381x EC-Declaration of Conformity — — en 7.1.570
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585
Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.05
Solenoids group 16D, standard voltages
Power Rated current Protec- Ex-Protection Tempera- Electrical Drawing Circuit Model
consumption tion class (ATEX-Category) ture connection diagram
IP/NEMA Ambient/
Media
24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
16,9 — 703 — IP65 — -25 ... +60 Connector 3 1 0800
(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)
11,4 — 475 — IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 4 4280
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
— 15,2 — 66 IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 7 4281
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 20 4680
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
— 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 21 4681
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 20 4682
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
—- 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 21 4683
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50
13,6 — 567 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3826
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
— 15,7 — 68 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3827
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals
Model Approvals Datasheet
ATEX IECEx FM
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.06 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Partnumbers for international approval
Land/Approval Coil/Code 029x 321x/381x 372x/382x 42xx 46xx 48xx
Europa/ATEX Standard x x – x x x
International/IECEx Standard x x – x x x
China/NEPSI -01 – – – x x –
Brasilien/INMETRO -02 – – – x x –
Korea/KOSHA (only gas approval) -03 – – – x x x
Russland, Kasachstan & Weißrussland/TR-CU 012 -04 x – – x x x
Indien/CCOE Standard – – – x x –
Taiwan/ITRI Standard – – – x x –
USA/FM Standard – – x – – –
Kanada/CSA Standard – – x – – –
Example: 0000000427002400-04
(Coil: 4270; Voltage: 24V DC; Approval: TR-CU 012)
Accessories
Electrical connection
Cable gland
Protection class Ex e, Ex d
(ATEX),
Nickel plated brass/
Stainless steel
Ambient
Page 10
temperatur
For sole- Cable Ø Protection class limitation
noid Thread (mm) Material (ATEX) *1) Model
42xx M20 x 1,5 7,0 … 12,0 Plastic II 2G Ex e / II 2D Ex t See table 0589735
42xx M20 x 1,5 10,0 … 14,0 Plastic II 2G Ex e / II 2D Ex t See table 0589736
42xx M20 x 1,5 6,0 … 12,0 Plastic II 2G Ex e / II 2D Ex t See table 0589737
42xx M20 x 1,5 5,0 … 10,0 Plastic II 2G Ex e / II 2D Ex t See table 0589739
46xx M20 x 1,5 5,0 ... 14,0 Nickel plated brass II 2G Ex e / II 2D Ex t - 0589654
46xx M20 x 1,5 10,0 … 14,0 Nickel plated brass II 2G Ex d / II 2D Ex t - 0588851
46xx 1/2 NPT 7,5 … 11,9 Nickel plated brass II 2G Ex d / II 2D Ex t - 0588925
46xx, 48xx M20 x 1,5 9,0 … 13,0 Stainless steel 1.4571 II 2G Ex e / II 2D Ex t - 0589385
46xx, 48xx M20 x 1,5 7,0 … 12,0 Stainless steel 1.4404 II 2G Ex d / II 2D Ex t - 0589395
46xx, 48xx M20 x 1,5 10,0 … 14,0 Stainless steel 1.4404 II 2G Ex d / II 2D Ex t - 0589387
*1) The limitation of the temperature range to the mentioned range is due to the self-heating of the
solenoid.
Connector
DIN EN 175301-803
0570275 (form A)
Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.07
Dimensions in mm
Projection/First angle
1 2
18
18
18
18
2
2
27 19
19
~ 120
~ 120
92,5
75,5
28,5
29,5
1 2 1 2
11
11
36 36 G 1/4
26
Drawings - Valve
3 4
18
18
27 19
27 19
~ 120
40,5
~ 120
~ 86
~ 40
92,5
1 2
1 2 75 G 1/2
46,5
~ 15,4
43
29,1
36
2 M4 x 6 mm deep
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.08 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Drawings - Solenoid Dimensions in mm
Weight: 0,15 kg Weight: 0,16 kg Projection/First angle
1 2
71 1 79 1
38 46
15,5
17
40,5
40,5
41,5
43
M16 x 1,5 12 M16 x 1,5 12
29,5
29,5
28
28
18 18
86,5 96,5
53,5 5 63,5
1
49 1 59
17
22
40,5
40,5
43
48
M16 x 1,5 12
M16 x 1,5 12
43
28
34
28
34
43
27 27
Weight: 0,5 kg
5 6 Weight: 0,4 kg 2
107
40,5
41
64,5
27
82,5
89
1
10
42
33
54,5
19,5
63,5
73
Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.09
Dimensions in mm
Weight: 0,8 kg Projection/First angle
Weight: 0,5 kg
7 8
70,5 2 2
41,5 1/2 NPT
40,5
53
20
84
1 59
14,5
63 2
33,5
43
56
26 4
1 4 5 6
7 20 21
T T
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.010 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22