Series 95000, 2/2

Direct solenoid actuated poppet valve


> Port size: 1/4” > For a.c. solenoid
(ISO G or NPT), G1/2 systems with integrat-
> Working from 0 bar up ed
rectifier (40 ... 60 Hz)
> Short switching times
> Variable valve solenoid
> Suited for fine vacuum combination
down to 1,33 x 10-2 mbar

Technical features
Medium: Orifice: Ambient/Media temperature: Material:
For neutral gaseous and liquid 1,5 ... 12 mm NBR: Housing: brass 2.0401 (Ms 58)
fluids (with contaminated fluids, Port size: -25 ... +80°C (-13 ... +176°F) Seals: NBR
upstream installation of a dirt G1/4, G1/2, 1/4 NPT FPM: other see option selector
trap is recommended) Flow direction: -10...+120°C (+14 ... +248°F) Inner parts: stainless steel 1.4104
Operation: Fixed Water +95°C (+203°F) (430 F), brass 2.0401 (Ms 58)
Direct solenoid operated Mounting position: EDPM:
poppet valve Optional, preferably -40... +140°C (-40 ... +284°F) Further versions
Operating pressure: with solenoid on top FFPM: Operating pressure to 50 bar;
0 ... 40 bar (0 ... 580 psi) -10....+140°C (+14 ... +284°F) Seat seals FPM, EPDM, FFPM,
PTFE: PTFE, Rubin;
-50....+180°C (-58 ... +356°F) Assembled oil and grease-free
Depending on solenoid system
and seal materials. Flow conversion:
Air supply must be dry enough Cv US Gallon/min (water) =
to avoid ice formation at l/min (air) x 0,001
temperatures below +2°C Kv m³/h (water) =
(+35°F). l/min (air) x 0,000906

Technical data
Housing: Brass, Seals: NBR -25 ... +80°C (-13 ... +176°F)
Symbol Port size Orifice Flow Operating pressure Weight Dimension Solenoid Model *1)
(mm) (l/min) (bar) (psi) (kg) (lbs) No. group
G1/4 1,5 70 0 ... 40 0 ... 580 0,21 0.46 1 13B 9500100
G1/4 2 120 0 ... 35 0 ... 507 0,21 0.46 1 13B 9500200
1/4 NPT 2 120 0 ... 35 0 ... 507 0,21 0.46 1 13B 9503200
G1/4 3 200 0 ... 10 0 ... 145 0,21 0.46 1 13C 9500300
12 2 10 12 2 10 1/4 NPT 3 200 0 ... 10 0 ... 145 0,21 0.46 1 13C 9503300
G1/4 4 350 0 ... 12 0 ... 174 0,21 0.46 1 13D 9500400
1 1 1/4 NPT 4 350 0 ... 12 0 ... 174 0,21 0.46 1 13D 9503400
G1/4 4 350 0 ... 14 0 ... 217 0,21 0.46 2 16D 9501400
12 2 10 12 2 10
G1/4 6 550 0 ... 5 0 ... 72 0,25 0.55 2 16D 9501600
1/4 NPT 6 550 0 ... 5 0 ... 72 0,25 0.55 2 16D 9504600
1 1 G1/2 12 1700 0 ... 1 0 ... 14 0,8 1.76 4 16D 9501700
12
12 2210 12 2 10
2 G1/4 2 100 0 ... 20 0 ... 290 0,21 0.46 3 13B 9502210
10 12 10
G1/4 3 160 0 ... 10 0 ... 145 0,21 0.46 3 13B 9502310
11 1
1
12 *1) When
2 10 12 ordering
2 10please indicate solenoid, voltage and current type (frequency).

1 1

12 2 10 12 2 10
Our policy is one of continued research and development. We therefore reserve the right to amend, 06/22
without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.01
1 1
Option selector 950x⭑x⭑.⭑⭑⭑⭑.⭑⭑⭑⭑
Orifice (mm) Substitute Voltage Substitute
1,5 1 24 V d.c. 02400
2 2 230 V a.c. 23050
3 3 Solenoid Substitute
4 4 See solenoid table
6 6
12 7
Material seat seal Substitute
NBR 0
EDPM 1
FPM 2
PTFE only orifice 1,5 ... 4 NC 3
FFPM 4
Rubin only orifice 2 ... 3 NC 5

Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.02 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Solenoids group 13B, standard voltages
Power Rated current Protection Ex-Protection Temperature Electrical Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
IP/NEMA Media

24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
8,0 — 331 — IP65 — -25 ... +60 Connector 1 1 0246
(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)

— 9,2 — 40 IP65 — -25 ... +60 Connector 2 7 3206


(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)

8,0 — 331 — IP65 II 3G Ex nA IIC T4 Gc -20 ... +60 Special 1 1 3216


(with II 3D Ex tc IIIB T110°C Dc connector
connector) incl.
DIN EN 175301-803,
form A
- 9,2 - 40 IP65 II 3G Ex nA IIC T4 Gc -20 ... +60 Special 2 6 3218
(with II 3D Ex tc IIIB T120°C Dc connector
connector) DIN EN 175301-803
Form A

6,9 - 289 - IP66 II 2G Ex mb IIC T3 Gb -20 ... +60 Cable length 3 m 5 4 0292
II 2D Ex mb IIIC T135°C Db

- 8,7 - 34 IP66 II 2G Ex mb IIC T3 Gb -20 ... +60 Cable length 3 m 5 7 0293


II 2D Ex mb IIIC T140°C Db

3,9 - 162 - IP66 II 2G Ex eb mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 6 4 4210
(with cable T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80

- 5,3 - 23 IP66 II 2G Ex eb mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 6 7 4211
(with cable T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80

3,9 - 162 - IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 1/2 NPT *1) 7 20 4610
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80

- 5,3 - 23 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 1/2 NPT *1) 7 21 4611
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80

3,9 - 162 - IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 7 20 4612
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80

— 5,3 — 23 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ...+80 M20 x 1,5 *1) 7 21 4613
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ...+80

5,5 — 228 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3722
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

— 5,9 — 26 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3723
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals
Model Approvals Datasheet
ATEX IECEx FM
029x KEMA 02 ATEX 1347 X IECEx DEK 13.0014X — en 7.1.505
321x, 381x EC-Declaration of Conformity — — en 7.1.570
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585

Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.03
Solenoids group 13C, standard voltages
Power Rated current Protection Ex-Protection Temperature Electrical Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
IP/NEMA Media

24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
12,1 — 504 — IP65 — -25 ... +60 Connector 1 1 0200
(with Media: DIN EN
connector) +80 max. 175301-803,
form A *1)
— 11,3 — 49 IP65 — -25 ... +60 Connector 2 6 3204
(with con- Media: DIN EN
nector) +80 max. 175301-803,
form A *1)
12,1 — 504 — IP65 II 3G Ex nA IIC T4 Gc -20 ... +60 Special 1 1 3217
(with II 3D Ex tc IIIB T130°C Dc connector
connector) DIN EN 175301-803
Form A

— 11,3 — 49 IP65 II 3G Ex nA IIC T4 Gc -20 ... +50 Special 2 6 3219


(with II 3D Ex tc IIIB T120°C Dc connector
connector) DIN EN 175301-803
Form A

10,7 — 446 — IP66 II 2G Ex mb IIC T3 Gb -20 ... +40 Cable length 3 m 5 4 0290
II 2D Ex mb IIIC T155°C Db

— 12,4 — 54 IP66 II 2G Ex mb IIC T3 Gb -20 ... +40 Cable length 3 m 5 7 0291


II 2D Ex mb IIIC T155°C Db

8,9 — 369 — IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +65 M20 x 1,5 *1) 6 4 4220
(with cable T5: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ... +65

— 10,0 — 43 IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +65 M20 x 1,5 *1) 6 7 4221
(with cable T5: -40 ... +55
gland) II 2D Ex tb IIIC T130°C Db -40 ... +65

8,9 — 369 — IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 1/2 NPT *1) 7 20 4620
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70

— 10,0 — 43 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 1/2 NPT *1) 7 21 4621
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70

8,9 — 369 — IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 M20 x 1,5 *1) 7 20 4622
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70

— 10,0 — 43 IP66 II 2G Ex db mb IIC T4/T6 Gb T4: -40 ... +70 M20 x 1,5 *1) 7 21 4623
(with cable II 2G Ex eb mb IIC T4/T6 Gb T6: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +70

8,9 — 369 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3724
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

— 9,5 — 41 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3725
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals
Model Approvals Datasheet
ATEX IECEx FM
029x KEMA 02 ATEX 1347 X IECEx DEK 13.0014X — en 7.1.505
321x, 381x EC-Declaration of Conformity — — en 7.1.570
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585

Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.04 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Solenoids group 13D, standard voltages
Power Rated current Protection Ex-Protection Temperature Electrical Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
IP/NEMA Media

24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
16,9 — 703 — IP65 — -25 ... +60 Connector 3 1 0700
(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)

— 19,5 — 75 IP65 — -25 ... +60 Connector 4 6 3703


(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)

11,4 — 475 — IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 4 4230
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

— 15,2 — 66 IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 7 4231
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 20 4630
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

— 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 21 4631
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 20 4632
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

— 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 21 4633
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

13,6 — 567 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3726
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

— 15,7 — 68 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3727
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals
Model Approvals Datasheet
ATEX IECEx FM
321x, 381x EC-Declaration of Conformity — — en 7.1.570
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585

Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.05
Solenoids group 16D, standard voltages
Power Rated current Protec- Ex-Protection Tempera- Electrical Drawing Circuit Model
consumption tion class (ATEX-Category) ture connection diagram
IP/NEMA Ambient/
Media
24 V DC 230 V AC 24 V DC 230 V AC
(W) (VA) (mA) (mA) (°C) No. No.
16,9 — 703 — IP65 — -25 ... +60 Connector 3 1 0800
(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)

— 17,3 — 75 IP65 — -25 ... +60 Connector 4 6 3803


(with Media: DIN EN 175301-803,
connector) +80 max. form A *1)

16,9 — 703 — IP65 II 3G Ex nA IIC T4 Gc -20 ... +55 Special 3 1 3817


(with II 3D Ex tc IIIB T130°C Dc connector
connector) DIN EN 175301-803
Form A

— 17,3 — 75 IP65 II 3G Ex nA IIC T4 Gc -20 ... +45 Special 4 6 3819


(with II 3D Ex tc IIIB T130°C Dc connector
connector) DIN EN 175301-803
Form A

11,4 — 475 — IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 4 4280
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

— 15,2 — 66 IP66 II 2G Ex eb mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 6 7 4281
(with cable T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 20 4680
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

— 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 1/2 NPT *1) 7 21 4681
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

11,4 — 475 — IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 20 4682
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

—- 15,2 — 66 IP66 II 2G Ex db mb IIC T4/T5 Gb T4: -40 ... +50 M20 x 1,5 *1) 7 21 4683
(with cable II 2G Ex eb mb IIC T4/T5 Gb T5: -40 ... +40
gland) II 2D Ex tb IIIC T130°C Db -40 ... +50

13,6 — 567 — 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3826
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

— 15,7 — 68 4x Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 5 3827
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories⭑
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals
Model Approvals Datasheet
ATEX IECEx FM
372x, 382x — — CSA-LR 57643-6 en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — en 7.1.585

Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.06 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Partnumbers for international approval
Land/Approval Coil/Code 029x 321x/381x 372x/382x 42xx 46xx 48xx
Europa/ATEX Standard x x – x x x
International/IECEx Standard x x – x x x
China/NEPSI -01 – – – x x –
Brasilien/INMETRO -02 – – – x x –
Korea/KOSHA (only gas approval) -03 – – – x x x
Russland, Kasachstan & Weißrussland/TR-CU 012 -04 x – – x x x
Indien/CCOE Standard – – – x x –
Taiwan/ITRI Standard – – – x x –
USA/FM Standard – – x – – –
Kanada/CSA Standard – – x – – –

Example: 0000000427002400-04
(Coil: 4270; Voltage: 24V DC; Approval: TR-CU 012)

Accessories
Electrical connection
Cable gland
Protection class Ex e, Ex d
(ATEX),
Nickel plated brass/
Stainless steel

Ambient
Page 10
temperatur
For sole- Cable Ø Protection class limitation
noid Thread (mm) Material (ATEX) *1) Model
42xx M20 x 1,5 7,0 … 12,0 Plastic II 2G Ex e / II 2D Ex t See table 0589735
42xx M20 x 1,5 10,0 … 14,0 Plastic II 2G Ex e / II 2D Ex t See table 0589736
42xx M20 x 1,5 6,0 … 12,0 Plastic II 2G Ex e / II 2D Ex t See table 0589737
42xx M20 x 1,5 5,0 … 10,0 Plastic II 2G Ex e / II 2D Ex t See table 0589739
46xx M20 x 1,5 5,0 ... 14,0 Nickel plated brass II 2G Ex e / II 2D Ex t - 0589654
46xx M20 x 1,5 10,0 … 14,0 Nickel plated brass II 2G Ex d / II 2D Ex t - 0588851
46xx 1/2 NPT 7,5 … 11,9 Nickel plated brass II 2G Ex d / II 2D Ex t - 0588925
46xx, 48xx M20 x 1,5 9,0 … 13,0 Stainless steel 1.4571 II 2G Ex e / II 2D Ex t - 0589385
46xx, 48xx M20 x 1,5 7,0 … 12,0 Stainless steel 1.4404 II 2G Ex d / II 2D Ex t - 0589395
46xx, 48xx M20 x 1,5 10,0 … 14,0 Stainless steel 1.4404 II 2G Ex d / II 2D Ex t - 0589387
*1) The limitation of the temperature range to the mentioned range is due to the self-heating of the
solenoid.

For sole- Ambient temperatur limitation solenoid 42xx


noid
0589735 & 0589736 *2) 0589737 0589739 *2)
T4 & Dust Ex: -35°C … + 80°C T4 & Dust Ex: -40°C…+ 65°C T4 & Dust Ex: -40…+78°C
421x/426x
T6: -35°C … + 55°C T6: -40°C…+ 55°C T6: -40…+55°C
T4 & Dust Ex: -35°C +65°C T4 & Dust Ex: -40°C…+ 62°C T4 & Dust Ex: -40…+65°C
422x/427x
T5: -35°C + 55°C T5: -40°C + 55°C T5: -40…+55°C
T4 & Dust Ex: -35°C…+50°C T4 & Dust Ex: -40°C…+50°C T4 & Dust Ex: -40…+50°C
423x/428x
T5: -35°C…+40°C T5: -40°C…+40°C T5: -40…+40°C
*2) Tested for the lower level of mechanical risk (4 joule), an
additional protection against impacts might be needed.

Connector
DIN EN 175301-803

0570275 (form A)

Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.07
Dimensions in mm
Projection/First angle
1 2
18
18

18
18

2
2
27 19
19

~ 120

~ 120
92,5

75,5
28,5

29,5
1 2 1 2
11

11
36 36 G 1/4
26
Drawings - Valve
3 4
18
18

27 19

27 19

~ 120
40,5
~ 120

~ 86
~ 40
92,5

1 2

1 2 75 G 1/2
46,5

~ 15,4
43
29,1

36

2 M4 x 6 mm deep

Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.08 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22
Drawings - Solenoid Dimensions in mm
Weight: 0,15 kg Weight: 0,16 kg Projection/First angle
1 2

71 1 79 1
38 46

15,5

17
40,5

40,5
41,5

43
M16 x 1,5 12 M16 x 1,5 12
29,5

29,5
28

28
18 18

3 Weight: 0,27 kg 4 Weight: 0,32 kg

86,5 96,5
53,5 5 63,5
1
49 1 59
17

22
40,5
40,5

43

48
M16 x 1,5 12
M16 x 1,5 12
43

28

34

28
34

43

27 27

Weight: 0,5 kg
5 6 Weight: 0,4 kg 2
107
40,5
41

64,5

27
82,5
89
1
10

42
33

54,5

19,5
63,5
73

1 Connector can be indexed by 4 x 90°


2 ø 16 or 13 (with spacer tube)

Our policy is one of continued research and development. We therefore reserve the right to amend,
06/22 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH en 5.4.304.09
Dimensions in mm
Weight: 0,8 kg Projection/First angle
Weight: 0,5 kg
7 8
70,5 2 2
41,5 1/2 NPT

40,5
53
20

84
1 59
14,5

63 2

33,5
43
56

26 4

29 43 2 ø 16 or 13 (with spacer tube)


122
3 M20 x 1,5 or 1/2 NPT

Circuit diagrams 4 Flying leads AWG 18 (460 mm long)

1 4 5 6

7 20 21

T T

Cable gland A B C øD Model


M20 x 1,5 10 40 7,0 ... 12,0 24 0589735
C C M20 x 1,5 10 43 10,0 ... 14,0 27 0589736
B D B D M20 x 1,5 10 40 6,0 ... 12,0 24 0589737
M20 x 1,5 10 39,5 5,0 ... 10,0 24 0589739
M20 x 1,5 6,5 35,5 5,0 …14,0 24 0589654
A

M20 x 1,5 12 37 9,0 … 14,0 30 0588851


1/2 NPT 15 58 7,5 ... 11,9 24 0588925
M20 x 1,5 6,5 27,5 9,0 ... 13,0 22 0589385
0588925 only
M20 x 1,5 16 40 7,0 … 12,0 24 0589395
EN - Englisch M20 x 1,5 16 41 10,0 … 14,0 24 0589387
Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of
systems only. Do not use these products where pressures and all component parts used in fluid power systems and to provide
temperatures can exceed those listed under »Technical features/ adequate safeguards to prevent personal injury or damage to
data«. equipment in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the
for non-industrial applications, life-support systems or other system instructional manual if protection against a failure mode
applications not within published specifications, consult cannot be adequately provided.
Norgren. System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with
Through misuse, age, or malfunction, components used in fluid
these products.
power systems can fail in various modes.

Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.304.010 without notice, the specifications given in this document. (2008 - 5120j) © 2020 Norgren GmbH 06/22