Technical features
Medium: Orifice: Ambient/Media temperature: Material:
Filtered, non-lubricated 6 mm (1/4”), 8 mm (1/2”) NBR: Body: Aluminium anodized
and dried compressed air, Port size: -40 ... +65°C (-40 ... +149°F) (suitable for high humidity,
instrument air, nitrogen and G1/4, 1/4 NPT, G1/2, 1/2 NPT HNBR: sulphuric, sodium chloride or
other non-flammable Flow direction: -25 ... +80°C (-13 ... +176°F) ammonia environments),
neutral, dry fluids Fixed Depending on solenoid system brass 2.0401 (Ms 58) or
Operation: Mounting position: Air supply must be dry enough stainless steel 1.4404 (316 L)
Indirect solenoid operated Optional, impulse valves to avoid ice formation at Seals: NBR or HNBR
spool valve preferably horizontally temperatures below +2°C.
Operating pressure: For outdoor installations must be Flow conversion:
2,5 ... 8 bar (36 ... 116 psi) protected all connections against Cv US Gallon/min (water) =
with internal air supply the penetration of moisture and l/min (air) x 0,001
0 ... 8 bar (0 ... 116 psi) a solenoid with IP66 protection Kv m³/h (water) =
with external air supply must be used! l/min (air) x 0,000906
Our policy is one of continued research and development. We therefore reserve the right to amend, 02/17
without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.01
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Technical data
Housing: Aluminium anodized, Seals: NBR -40 ... +65°C (-40 ... +149°F) / IEC 61508: -40 ... +40°C (-40 ... +104°F)
Symbol Port Orifice Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 x 0,5 1 9713535
12 2 10 12 2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 0,5 1 9713545
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 2 9713555
1 3 1 3
1/2 NPT 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 2 9713565
12 2 10 12G1/4 2 106 Solenoid/spring 1300 2,5 ... 8 x 0,7 3 9710535
14 4 2 12 14 4 2 12
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 0,7 3 9710545
1 3 1 3
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,7 4 9710555
51 3 51 3
12 2 10 121/2 NPT2 108 Solenoid/spring 2600 2,5 ... 8 — 0,7 4 9710565
14 4 2 12 14 4 2 12
G1/4 6 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 5 9711535
14 4 2 12 14 1 34 2 12
1 3 1/4 NPT 6 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 5 9711545
51 3 51 3
G1/2 8 Solenoid/solenoid 2600 2,5 ... 8 — 0,8 6 9711555
51 3 51 3
14 4 2 12 NPT 48 2 12
1/2 14 Solenoid/solenoid 2600 2,5 ... 8 — 0,8 6 9711565
14 4 2 2 12
4 14
G1/4
4 2
46 212 Solenoid/solenoid 950 2,5 ... 8 — 0,7 7 9712535
14 12 14 12
51 3 1/4 NPT 5
61 3 Solenoid/solenoid 950 2,5 ... 8 — 0,7 7 9712545
51 3 51 3
51 3 51 3
4 2 12 4 2 212
1414 4 2 12 1414 4 12
Housing: Brass, Seals: NBR -40 ... +65°C (-40 ... +149°F) / IEC 61508: -40 ... +40°C (-40 ... +104°F)
51 3 51 3
Symbol 51 3 Port 51 3
Orifice Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
14 4 2 12 14 4 2 12
G1/4 6 Solenoid/spring 1300 2,5 ... 8 x 1 1 9713635
12 2 10 12 2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 1 1 9713645
51 3 51 3
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 1 2 9713655
1 3 1 3
1/2 NPT 8 Solenoid/spring 2600 2,5 ... 8 — 1 2 9713665
12 2 10 12G1/4 2 106 Solenoid/spring 1300 2,5 ... 8 x 1,7 3 9710635
14 4 2 12 14 4 2 12
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 1,7 3 9710645
1 3 1 3
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 1,7 4 9710655
51 3 51 3
12 2 10 121/2 NPT2 108 Solenoid/spring 2600 2,5 ... 8 — 1,7 4 9710665
14 4 2 12 14 4 2 12
G1/4 6 Solenoid/solenoid 1300 2,5 ... 8 — 1,7 5 9711635
14 4 2 12 14 1 34 2 12
1 3 1/4 NPT 6 Solenoid/solenoid 1300 2,5 ... 8 — 1,7 5 9711645
51 3 51 3
G1/2 8 Solenoid/solenoid 2600 2,5 ... 8 — 1,9 6 9711655
51 3 51 3
14 4 2 12 NPT 48 2 12
1/2 14 Solenoid/solenoid 2600 2,5 ... 8 — 1,9 6 9711665
14 4 2 12 14 4 2 12
51 3 51 3
51 3 51 3
Housing: Stainless steel, Seals: NBR -40 ... +65°C (-40 ... +149°F) / IEC 61508: -40 ... +40°C (-40 ... +104°F)
14 4 2 12 14 4 2 12
Symbol Port Orifice Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
51 3 G1/4 5 16 3 Solenoid/spring 1300 2,5 ... 8 x 1,1 1 9713735
12 2 10 12 2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 1,1 1 9713745
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 1,1 2 9713755
1 3 1 3
1/2 NPT 8 Solenoid/spring 2600 2,5 ... 8 — 1,1 2 9713765
12 2 10 12G1/4 2 106 Solenoid/spring 1300 2,5 ... 8 x 1,8 3 9710735
14 4 2 12 14 4 2 12
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 1,8 3 9710745
1 3 1 3
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 1,8 4 9710755
51 3 51 3
12 2 10 121/2 NPT2 108 Solenoid/spring 2600 2,5 ... 8 — 1,8 4 9710765
14 4 2 12 14 4 2 12
G1/4 6 Solenoid/solenoid 1300 2,5 ... 8 — 1,8 5 9711735
14 4 2 12 14 1 34 2 12
1 3 1/4 NPT 6 Solenoid/solenoid 1300 2,5 ... 8 — 1,8 5 9711745
51 3 51 3
G1/2 8 Solenoid/solenoid 2600 2,5 ... 8 — 1,9 6 9711755
51 3 51 3
14 4 2 12 NPT 48 2 12
1/2 14 Solenoid/solenoid 2600 2,5 ... 8 — 1,9 6 9711765
14 4 2 12 14 4 2 12
*1) When ordering please indicate solenoid, voltage and current type (frequency)
51 3 51 3
51 3 51 3
14 4 2 12 14 4 2 12
51 3 51 3
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.02 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Housing: Aluminium anodized, Seals: HNBR -25 ... +80°C (-13 ... +176°F) /
IEC 61508: -25 ... +65°C (-13 ... +149°F) or 0 ... +80°C (0 ... +176°F)
Symbol Port Orifice Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 x 0,5 1 9713235
12 2 10 12 2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 0,5 1 9713245
Symbol
14 4 2 12 Port14 4Orifice
2 12 Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 x 1 1 9713335
12 5 1 3 2 10 12 2 10 5 1 3
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 x 1 1 9713345
51 3 51 3
51 3 51 3
14 4 2 12 14 4 2 12
51 3 51 3
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.03
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
0,8 — 38 — IP66 (with II 2G Ex eb mb IIC T5/T6 Gb T5: -40 ... +80 M20 x 1,5 *1) 6 4 4200
cable gland) T6: -40 ... +70
II 2D Ex tb IIIC T130°C Db -40 ... +80
— 1,3 — 6 IP66 (with II 2G Ex eb mb IIC T5/T6 Gb T5: -40 ... +80 M20 x 1,5 *1) 6 7 4201
cable gland) T6: -40 ... +70
II 2D Ex tb IIIC T130°C Db -40 ... +80
0,8 — 33 — IP66 (with II 2G Ex d mb IIC T5/T6 Gb T5: -40 ... +80 1/2 NPT *1) 7 20 4600
cable gland) II 2G Ex e mb IIC T5/T6 Gb T6: -40 ... +70
II 2D Ex tb IIIC T130°C Db
— 1,3 — 6 IP66 (with II 2G Ex d mb IIC T5/T6 Gb T5: -40 ... +80 1/2 NPT *1) 7 21 4601
cable gland) II 2G Ex e mb IIC T5/T6 Gb T6: -40 ... +70
II 2D Ex tb IIIC T130°C Db
0,8 — 33 — IP66 (with II 2G Ex d mb IIC T5/T6 Gb T5: -40 ... +80 M20 x 1,5 *1) 7 20 4602
cable gland) II 2G Ex e mb IIC T5/T6 Gb T6: -40 ... +70
II 2D Ex tb IIIC T130°C Db
— 1,3 — 6 IP66 (with III 2 G Ex d mb IIC T5/T6 Gb T5: -40 ... +80 M20 x 1,5 *1) 7 21 4603
cable gland) II 2G Ex e mb IIC T5/T6 Gb T6: -40 ... +70
II 2D Ex tb IIIC T130°C Db
0,8 — 33 — IP66 (with II 2G Ex mb d IIC T4/T6 Gb T4: -40 ... +80 M20 x 1,5 *1) 10 4 4802
cable gland) II 2G Ex mb e II T4/T6 Gb T6: -40 ... +70
— 1,3 — 6 IP66 (with II 2G Ex mb d IIC T4/T6 Gb T4: -40 ... +80 M20 x 1,5 *1) 10 7 4803
cable gland) II 2G Ex mb e II T4/T6 Gb T6: -40 ... +70
1,4 — 228 — 4X Cl. I, Div. 1, Gr. A - D -20 ... +60 Flying leads 8 1 3720
Cl. II/III, Div. 1, Gr. E - G length 460 mm
T3C (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories«
*2) Required connector: type 0570275 for d.c.; type 0663303 for a.c., 200 V d.c. solenoid voltage must be ordered!
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals
Model Approvals Datasheet
ATEX IECEx FM
029x KEMA 02 ATEX 1347 X IECEx DEK 13.0014X — N/en 7.1.505
372x, 382x — — CSA-LR 57643-6 N/en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — N/en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — N/en 7.1.585
48xx PTB 06 ATEX 2054 X IECEx PTB 07.0039X — N/en 7.1.590
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.04 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
391 24 460 11 IP66 (with II 2G Ex ia IIC T4/T6 Gb T4: -40 ... +80 17 10 2051
cable gland) T6: -40 ... +60
II 2D Ex ia IIIC T80°C Db -40 ... +60
736 17 880 15 IP66 (with II 2G Ex ia IIC T4/T6 Gb T4: -40 ... +80 17 10 2052
cable gland) T6: -40 ... +60
II 2D Ex ia IIIC T80°C Db -40 ... +60
1220 13 1460 19 IP66 (with II 2G Ex ia IIC T4/T6 Gb T4: -40 ... +80 17 10 2053
cable gland) T6: -40 ... +60
II 2D Ex ia IIIC T80°C Db -40 ... +60
Approvals
Model Approvals Datasheet
ATEX IECEx
205x PTB 07 ATEX 2019 IECEx PTB 07.0017 N/en 7.1.535
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.05
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
51 3 51 3
Housing:5 1Brass,
3 Seals: NBR
5 1 3-40 ... +65°C (-40 ... +149°F)
Symbol
14 4 2 12 Port14 4Orifice
2 12 Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713639
12 5 1 3 2 10 12 2 10 5 1 3
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713649
51 3 3 51
Housing: 5Stainless
13 steel, 5Seals:
13 NBR -40 ... +65°C (-40 ... +149°F)
Symbol 4 2 12 Port 4 Orifice
2 12 Actuation/return Flow Operating Test certificate Weight Dimension Model
14 14
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713739
12 5 123 10 12 51 3
2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713749
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 9 9713759
1 3 1 3
1/2 NPT 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 9 9713769
12 2 10 12G1/4 2 106 Solenoid/spring 1300 2,5 ... 8 — 0,7 10 9710739
14 4 2 12 14 4 2 12
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,7 10 9710749
1 3 1 3
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,7 11 9710759
51 3 51 3
12 2 10 121/2 NPT2 108 Solenoid/spring 2600 2,5 ... 8 — 0,7 11 9710769
14 4 2 12 14 4 2 12
14 4 2 12 G1/4
14 4 62 12 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 12 9711739
1 3 1
1/4 NPT 3 6 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 12 9711749
51 3 51 3
51 3 51 3
14 4 2 12 14 4 2 12
*1) When 4 2 please
14 ordering 12 indicate 4 2 12
14 solenoid, voltage and current type (frequency)
51 3 51 3
51 3 51 3
14 4 2 12 14 4 2 12
51 3 51 3
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.06 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Housing: Aluminium anodized, Seals: HNBR -25 ... +80°C (-13 ... +176°F)
Symbol Port Orifice Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713239
12 2 10 12 2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713249
14 4 2 4 2
14 4 2 12 12 14
14 4 2 12 12
5 1531 3 5 1531 3
Housing:
14 4 2Brass,
12
Seals:
14
HNBR
4 2 -25
12
... +80°C (-13 ... +176°F)
Symbol Port Orifice Actuation/return Flow Operating Test certificate Weight Dimension Model
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
51 3 51 3
G1/4 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713339
12 2 10 12 2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713349
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 9 9713359
1 3 1 3
1/2 NPT 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 9 9713369
12 2 10 12G1/4 2 106 Solenoid/spring 1300 2,5 ... 8 — 0,7 10 9710339
14 4 2 12 4 2 12
1/4 14
NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,7 10 9710349
1 3
G1/2 1 3
8 Solenoid/spring 2600 2,5 ... 8 — 0,7 11 9710359
51 3 51 3
12 2 10 121/2 NPT2 108 Solenoid/spring 2600 2,5 ... 8 — 0,7 11 9710369
14 4 2 12 14 4 2
14 4 2 12 G1/4
14 4 62 1212 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 12 9711339
1 3 1 3 6
1/4 NPT Solenoid/solenoid 1300 2,5 ... 8 — 0,7 12 9711349
51 3 51 3
51 3 51 3
Housing: 5Stainless
15 13 3 steel, 5Seals:
5 13 3
1 HNBR -25 ... +80°C (-13 ... +176°F)
Symbol 4 2 12 Port 4 Orifice
2 12 Actuation/return Flow Operating Test certificate Weight Dimension Model
14 14
size (mm) (l/min) pressure (bar) IEC 61508 (kg) No. *1)
G1/4 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713739
12 5 123 10 12 51 3
2 10
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,5 8 9713749
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 9 9713759
1 3 1 3
1/2 NPT 8 Solenoid/spring 2600 2,5 ... 8 — 0,5 9 9713769
12 2 10 12G1/4 2 106 Solenoid/spring 1300 2,5 ... 8 — 0,7 10 9710739
14 4 2 12 14 4 2 12
1/4 NPT 6 Solenoid/spring 1300 2,5 ... 8 — 0,7 10 9710749
1 3 1 3
G1/2 8 Solenoid/spring 2600 2,5 ... 8 — 0,7 11 9710759
51 3 51 3
12 2 10 121/2 NPT2 108 Solenoid/spring 2600 2,5 ... 8 — 0,7 11 9710769
14 4 2 12 14 4 2 12
14 4 2 12 G1/4
14 4 62 12 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 12 9711739
1 3 1
1/4 NPT 3 6 Solenoid/solenoid 1300 2,5 ... 8 — 0,7 12 9711749
51 3 51 3
51 3 51 3
14 4 2 12 14 4 2 12
*1) When 4 2 please
14 ordering 12 indicate 4 2 12
14 solenoid, voltage and current type (frequency)
51 3 51 3
51 3 51 3
14 4 2 12 14 4 2 12
51 3 51 3
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.07
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
23,2 (+20°C) ≥ 16 (+20°C) ≤ 5,4 (+20°C) ≥ 1,45 10900 IP65 (with cable II 2G Ex ia IIC T4/T6 T4: -40 ... +80°C 11 2086
≥ 16,8 (+80°C) ≤ 4,7 (-25°C) gland) T6: -40 ... +60°C
Max. values Ex i
Ui li Pi *1)
(V) (mA) (mW)
25 150 250
27 125 250
28 115 250
30 100 250
32 85 250
Air consumption: home position ≤ 60 l/h,
operating position ≤ 15 l/h
*1) Model 2086 without Pi limiting. Ci
and Li can be ignored.
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.08 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Example: 0000000420002400-04
(Coil: 4200; Voltage: 24V DC; Approval: TR-CU 012 )
Accessories
Electrical connection
Cable gland For Ambient temperatur limitation solenoid 42xx
Protection class Ex e, Ex d solenoid
0589735 & 0589736 *2) 0589737
(ATEX),
Nickel plated brass/ 420x/425x T5 & Dust Ex: -35°C … + 80°C T5 & Dust Ex: -40°C…+68°C
Stainless steel T6: -35°C … +70°C T6: -40°C…+68°C
*2) Tested for the lower level of mechanical risk (4 joule), an additional
Page 17 protection against impacts might be needed.
Ambient
For Cable Ø Protection temperatur Connector
solenoid Thread (mm) Material class (ATEX) limitation *1) Model DIN EN 175301-803
42xx M20 x 1,5 7,0 … 12,0 Plastic II 2G Ex e / II 2D Ex t Siehe Tabelle 0589735
42xx M20 x 1,5 10,0 … 14,0 Plastic II 2G Ex e / II 2D Ex t Siehe Tabelle 0589736
42xx M20 x 1,5 6,0 … 12,0 Plastic II 2G Ex e / II 2D Ex t Siehe Tabelle 0589737
46xx M20 x 1,5 5,0 … 8,0 Nickel plated brass II 2G Ex e / II 2D Ex t - 0588819
46xx M20 x 1,5 10,0 … 14,0 Nickel plated brass II 2G Ex d / II 2D Ex t - 0588851
46xx 1/2 NPT 7,5 … 11,9 Nickel plated brass II 2G Ex d / II 2D Ex t - 0588925 Page 9
46xx, 48xx M20 x 1,5 9,0 … 13,0 Stainless steel 1.4571 II 2G Ex e / II 2D Ex t - 0589385 0570275 (form A)
46xx, 48xx M20 x 1,5 7,0 … 12,0 Stainless steel 1.4404 II 2G Ex d / II 2D Ex t - 0589395 0663303 (with rectifier)
46xx, 48xx M20 x 1,5 10,0 … 14,0 Stainless steel 1.4404 II 2G Ex d / II 2D Ex t - 0589387
*1) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
Valve
Adaptor complete Inlet filter Silencer (plastic) *1) Silencer (stainless steel) Silencer (brass) *1) Exhaust guard *2)
(Adaptor, inlet filter and *1)
seal ring)
0613487 (G1/4) 0681173 (G1/4, 1/4 NPT) M/S2 (G1/4) 0014613 (G 1/4) T40C2800 (G 1/4) 0613422 (G1/4, 1/4 NPT)
C/S2 (1/4 NPT) 0613678 (1/4 NPT) MS002A (1/4 NPT) 0613423 (G1/2, 1/2 NPT)
M/S4 (G1/2) 0014813 (G 1/2) T40C4800 (G 1/2)
C/S4 (1/2 NPT) 0613679 (1/2 NPT) MS004A (1/2 NPT)
*1) For indoors use only
*2) For outdoors use, opening pressure ~ 0,2 bar
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.09
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Drawings Dimensions in mm
Projection/First angle
Valves
1 2
A
A
1 34 30,5 1 25 58,5
3 1 3 1
55
55
30
36
5,5
36
36
2 2
53 5,5 61,5
A
A
~ 109 125,5
~ 164 ~178,5
2 3 2 3
3,5
1,5
1,5
3,5
30
34
1,5
0
1
24 40,5 92 32 42
82 95
3 4
1 63
A
74
A
1
5,5
4 2
4 2
55
24
55
42
5,5
36
36
5 1 3 5 1 3
22 22 32 32
A
32 41
A
47 58
129
147
~184
~202
2 3
2 3
3,5
1
2
30
34
1
0
1
0
24 32
70 28 86 31
A-A
9 10 1 Solenoid dimensions see page 16
2 External control pressure connection G1/8, 1/8 NPT
3 Working port G1/4, G1/2 or 1/4 NPT, 1/2 NPT
9 Position of gasket internal pilot air
10 Position of gasket external pilot air
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.10 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Dimensions in mm
5 Projection/First angle
12
A-A B-B
B
1
4 2
5,5
24
55
36
5 1 3
9 9
22 22
B
A
111 32
121
132
~242
10 10
2 3
0
1
30
1
0
12
24
86 70
6
A
4 2
55
42
5,5
36
5 1 3
32 32
A
106 47
164
~ 274
2 3
3,5
2
34
1
0
1
0
32
94 86
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.11
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Dimensions in mm
7 Projection/First angle
12
B
1 A-A B-B
4 2
24
5,5
55
36
5 1 3
22 22 9 9
A
B
129 32
150
~260
2 3 0 10 10
1
1
30
1
0
12
24
104 70
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.12 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Dimensions in mm
8 9 Projection/First angle
4
4
C
C
53 25 58,5
5,5
3 1 3 1
74
74
36
55
55
30
2 2
34 30 5,5 61,5
55
C
C
55
145 ~158
23,5 2 3
23,5 2 3
1,5
3,5
1,5
3,5
34
30
1,5
24 40,5 32 42
82 95
10 11
4 4
63 74
C
4 2
5,5
4 2
74
74
5
55
42
24
55
5 1 3 5 1 3
22 22 5,5
55 32 41
C
55 32 32
c
165 47 58
182,5
23,5 2 3 23,5 2 3
3,5
2
1
34
30
24 32
70 86
P ext.
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.13
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Dimensions in mm
12 4 Projection/First angle
12 5,5
D
C
C-C D-D
4 2
74
P int.
P int.
P ext.
P ext.
24
55
5 1 3
C
D
55 22 22
92 32
102
204
23,5 2 3 9 9
1
30
24
10 10
114
67 70
13
4
C
4 2
74
42
55
5 1 3
5,5
55
C
32 32
77,5 47
~ 217
23,5 2 3
3,5
2
34
32
65,5 86
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.14 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Dimensions in mm
14 Projection/First angle
4
24 5,5
12
D
4 2 C-C D-D
74
P int.
P int.
P ext.
P ext.
24
55
5 1 3
C
D
55 22 22
110 32
120
~222
9 9
2 3
1
30
132 10 10
85 70
04 005
8
17.5 27
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.15
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
Drawings Dimensions in mm
Projection/First angle
Solenoids
Weight: 0,3 kg Weight: 0,4 kg
3 5
86,5
53,5 5
49 1
41
17
82,5
40,5
43
89
M16 x 1,5 12
33
19,5
63,5
43
28
34
73
27
41,5
64,5
53
27
20
1 1
10
59
14,5
42
54,5
56
29 43
122
41
45
43
84
53
15 + 1
63 2 3
33,5
43
56
26 4
28 35
1 Connector 4 x 90° turnable
113
2 Ø 13 (with spacer tube)
3 M20 x 1,5 or 1/2 NPT
4 Flying leads 460 mm long
5 Connector with rectifier(0663303)
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.16 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
1
107
40,5
64,5
27
10
42
54,5
Circuit diagrams
1 4 5 7
10 11 20 21
T T
Cable gland
C C A B C øD Model
B D B D M20 x 1,5 10 40 7,0 ... 12,0 24 0589735
M20 x 1,5 10 43 10,0 ... 14,0 27 0589736
M20 x 1,5 10 40 6,0 ... 12,0 24 0589737
A
Our policy is one of continued research and development. We therefore reserve the right to amend,
02/17 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH en 5.4.285.17
97105 Inline, 3/2, 5/2 & 5/3
Indirect solenoid actuated spool valves
1,5
Ø 10,5
G1/4
G1/4
13
8,5
60°
19
21 14,5 8,5
5
28,5 60°
C C
G G
øD
øD
B
B
B G C ØD Weight (g) Model B Suitable for G C ØD Weight (g) Model
G1/4 7 35,5 15,5 2,9 M/S2 1/4” G1/4, 1/4 NPT 10 26,5 21 5 0613422
1/4 NPT 7 35,5 15,5 2,9 C/S2 1/2” G1/2, 1/2 NPT 12 33,5 29 11 0613423
G1/2 12 67 23 11,5 M/S4
1/2 NPT 12 67 23 11,5 C/S4
14 14 14
~11 ~11
~16
M10 x 0,5
M10 x 0,5
M10 x 0,5
EN - Englisch
Warning
These products are intended for use in industrial compressed air and fluid Through misuse, age, or malfunction, components used in fluid power
systems only. Do not use these products where pressures and systems can fail in various modes. The system designer is warned to
temperatures can exceed those listed under »Technical features/data«. consider the failure modes of all component parts used in fluid power
Before using these products with fluids other than those specified, for systems and to provide adequate safeguards to prevent personal injury
non-industrial applications, life-support systems, or other applications not or damage to equipment in the event of such failure.
within published specifications, consult System designers must provide a warning to end users in the system
IMI Precision Engineering, Norgren GmbH. instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings
found in instruction sheets packed and shipped with these products.
Functional safety (SIL):
Suitable for certain applications can only be evaluated through examina-
tion of each safety-related overall system with regard to the requirements
of IEC 61508/61511.
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.4.285.18 without notice, the specifications given in this document. (2004 - 5118h) © 2015 Norgren GmbH 02/17