Integrated stepper motor driver
FD1.6 belongs to FD family micro-stepper drives. It is designed in a compact solution to be mounted directly on motor end-shield.
MAIN CHARACTERISTICS FD drives are all controlled by 72 MHz ARM-based microcontroller. They
are equipped with very low RDS-on MOSFETs and Hall effect current
Supply voltage 24 – 80 VDC sensors to optimize power efficiency.
Motor current Up to 7 AP per phase
FD1.6 is the hardware code of the open frame type. The suffix B (e.g.
Motor type Bipolar, 4 wires
IP 40 and 65 FD1.6B) identifies the model protected by a cover IP40 and the suffix W
is the IP65 version. The aluminum cover works also as heat sink, allowing
Inputs 4 Digital opto-insulated
higher motor currents.
Outputs 2 Digital pnp-type
Field-bus interfaces Modbus (RS-232, RS-485)
The drive is equipped with 12-bit magnetic encoder, which can be used
CANopen DSP 402
Encoder 12-bit/rev absolute single revolution to verify the correct execution of the ordered steps, to modulate the
motor current with the load and other functions which are described in
Dimensions [mm] FD1.6 60 x 60 x 15 + motor
detail on firmware manuals.
FD1.6B 69 x 69 x 26 + motor
FD1.6W 69 x 69 x 27 + motor
FD1.6 is equipped with configurable I/O’s (4 inputs and 2 outputs), which
FEATURES can be used as step / dir or quadrature steps, start, stop and cycle
selection mode, plus transceivers RS-232 (from 4 800 up to 115 200 bps)
and RS-485 (from 4 800 up to 921 600 bps) for Modbus communication.
• Torque Control loop The suffix A identifies the model equipped with CAN transceiver, e.g.
Adjustable IMAX (current at maximum torque) FD1.6A, FD1.6AB. CANopen protocol is implemented (from 10 kHz up to
Adjustable IMIN (current at no torque) 1 MHz).
• Step accumulator with programmable alarm limit To avoid unwanted heat dissipation FD1.6 implements motor torque
control, which reduce the current in absence of resistant torque and
• 12-bit absolute encoder increase it proportionally with the load till the maximum value
Absolute multi-turn position recovery at power on configured. Torque control is active all the times, also at zero speed,
which means that if a load is applied when the motor is stopped, the
• Step / dir or quadrature steps drive will counteract the load, increasing motor current.
• 32 programmable cycles, 10 cycles sequences The step accumulation function provides great benefits to the
Predefined movements can be selected, started, stopped using digital application: it allows to accumulate the steps which cannot be executed
inputs. Configurable speed, acceleration, deceleration, target position because of a sudden resistant torque above the maximum motor torque.
with linear, parabolic and jerk motion profiles. In this case FD1.6 maintains the maximum motor torque and, when the
Complex cycles as homing, delta stop, delay or sequence of cycles are load decreases, it recovers the steps accumulated, accelerating and
also selectable and started. reaching the reference position. The engage, which is the change from
chasing mode to synchronous mode, takes place through bump-less
• Position resolution speed adjustment, without vibrations.
Configurable µsteps per revolution (400 – 208 400 µsteps/rev)
• Over temperature (100 °C), over voltage and short circuit alarms