0% found this document useful (0 votes)
108 views

Technical Data Sheet-DOL - Submit

This technical data sheet provides specifications for an IEC LV motor for direct online use. The motor is a 3-phase, squirrel cage induction motor with a rated output of 160 kW, voltage of 400 V, and frequency of 50 Hz. It has an efficiency of 94.9% at full load and meets the requirements of efficiency class IE2.

Uploaded by

har singkawang
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views

Technical Data Sheet-DOL - Submit

This technical data sheet provides specifications for an IEC LV motor for direct online use. The motor is a 3-phase, squirrel cage induction motor with a rated output of 160 kW, voltage of 400 V, and frequency of 50 Hz. It has an efficiency of 94.9% at full load and meets the requirements of efficiency class IE2.

Uploaded by

har singkawang
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

IEC LV Motors Technical Data Sheet - DOL

Project Location

Department/Author Customer name Customer ref Item name


1,00001
Our ref. Rev/Changed by Date of issue Saving ident Pages
A 30/01/2023 untitled.xlsm 1(3)
No. Definition Data Unit Remarks
1 Product TEFC, 3-phase, squirrel cage induction motor
2 Product code 3GBA 312 230-BDH Calc. ref. 3GZC021031-195
3 Type/Frame M2BAX 315SMC 4
4 Mounting IM3001, B5(flange)
5 Rated output PN 160 kW
6 Service factor 1
7 Type of duty S1(IEC) 100%
8 Rated voltage UN 400 VD ± 5 % (IEC 60034-1)
9 Rated frequency fN 50 Hz ± 2 % (IEC 60034-1)
10 Rated speed nN 1484 r/min
11 Rated current IN 283 A
12 No-load current 100 A
13 Starting current Is/IN 7,5 Meet IEC 60034-12, N,(H at 60 Hz)
14 Nominal torque TN 1030 Nm
15 Locked rotor torque TS/TN 3,4
16 Maximum torque Tmax/TN 3,1
17 Minimum torque Tmin/TN 2,1
18 Speed at minimum torque 1200 r/min
Load characteristics (IEC 60034-2-1:2014) Load % Current A Efficiency % Power factor
19 PLL determined from residual loss 100 283 94,9 / IE2 0,85
20 75 222 95,1 0,82
21 50 167 94,7 0,73
22 Start 2122 0,39
23 Maximum starting time from hot 28 s
24 Maximum starting time from cold 50 s
25 Insulation class / Temperature class F/F
26 Ambient temperature 40 °C
27 Altitude 1000 m.a.s.l.
28 Enclosure IP55
29 Cooling system IC411 self ventilated
30 Bearing DE/NDE 6319/C3 - 6316/C3
31 Type of Grease
32 Sound pressure level (LP dB(A) 1m) 68 dB(A) at load
33 Moment of inertia J = ¼ GD2 2,9 kg-m2
34 Balancing
35 Vibration class
36 Position of terminal box Top
37 Terminal box entries; no, dimens.
38 Number of power terminals
39 Direction of rotation CW or CCW
40 Weight of rotor 229 kg
41 Total weight of motor 900 kg
42 Dimension drawing no.
43
44
45
Ex-motors
46
47
48
Option Variant Codes / Definition
49
50
51
52

Remarks:

Data based on situation 14/07/2022


All data subject to tolerances in accordance with IEC
Guaranteed values on request