Contact ID Reporting Codes v1.4
Contact ID Reporting Codes v1.4
com
Table of Contents
1. Pacom RTU Contact ID Reporting Codes . . . . . . . . . . . . . . . . . . . . . . . .1
1.1 Dial Backup Details & Message Filtering:. . . . . . . . . . . . . . . . . . . . .1
1.1 External Alarm Zones: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.2 Other Panel Internal Alarms: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.2.1 Tamper Alarms: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.2.2 Offline Alarms: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2.3 General Fail Alarms: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2.4 A.C. Fail: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2.5 Battery Low: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.2.6 Film Low: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.2.7 Film Out:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.2.8 General Alarm: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.2.9 Status Reports: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.2.10 Opens, Closes and Modes: . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
1.2.11 Communications Alarms: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
1.2.12 Output Operations:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.2.13 Reminder Reports: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.2.14 Card Access Reporting: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.2.15 DOOR Access Reporting: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.2.16 Supervisor Commands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.3 Backward Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.4 Alarm Panel Commands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.5 RTU Commands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1.6 RTU Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.7 Alarm Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 1
Messages are sent using the standard Ademco Contact ID message format:
R U
<LF>00 rrrr 18 Exxx gg Cyyy <CR>
Where:
<LF> is the ASCII line feed character
"rrrr" is the RTU number 0001 -> 9998 (9999 for all base station messages)
"xxx" is the event code
"gg" is the group or area number
"yyy" is the zone number
<CR> is the ASCII carriage return character
All characters are sent as ASCII, including the spaces where shown. The letters 'E' and 'R' are
alternatives, 'E' being for alarm events and 'R' being for restore events. The letters 'C' and 'U' are also
alternatives, 'C' being for zone number and 'U' being for user number. Most events include a zone
number. Only a few opening and closing type messages have user numbers. All messages must be
responded to with either an ACK (1400Hz tone within 1 second) or NAK (no tone for 1 second).
The following lists define the event, group and zone field entries for each type of message in the
format:
• Exxx gg CzzzAlarm event
• or Rxxx gg Czzz Restore event
• or Exxx gg Uzzz Opening event with user number
• or Rxxx gg Uzzz Closing event with user number
Generally only the alarm or opening event is indicated but occasionally the restore or closing event may
be indicated for clarity.
2. This connect message will be filtered from the dialup message queue before being put into the
queue so that it doesn't get sent via Contact ID and so it doesn't increment the non-important alarms
counter .
3. Error stats are added to help for diagnoses what is happening/causing the controller to dial out and
also any Nak's and the like.
• Number of Important alarms
• Number of Non-important alarms
• Number of dialout due to heartbeat time set.
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
2 Pacom RTU Contact ID Reporting Codes
"Apply Message Filters before Dialup" flag setting in (Port Parameters-> Modem -> Base Station tab->
Parameters) will decide the filtering of the messages to be done or not before putting onto the queue
based on filter messages setting. It applies for all types of reporting (Pacom, Contact ID, SIA, and
SMS).
If there is a port with Backup Priority (Dual Reporting), and is not a Pacom message then the connect
message will also be filtered.
If the "Dialup Type" option is selected in (Port Parameters-> Modem -> Base Station tab-> Parameters)
then based on the type selected the heatbeat message is reported to the receiver.
Timings for heartbeat reporting based on Dialup Type numbers 1 to 8 for Contact ID and SIA formats
are:
If the "Dialback time" & "Random time between time specified (+/-30 mins)" are set then based on the
time selected with +/- 30minutes of the time selected it reports it to the receiver. If the "Random time
between time specified (+/-30 mins)" flag is not set then it reports at the exact time selected.
Note: A Periodic Test report message with Event code '602' and zone number '001' is sent for heartbeating
message transmission (TX) only.
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 3
E130 gg C001 -> E130 gg C256 E602 gg C001 -> E602 gg C256
External normal alarm External alarm zone tested
E380 gg C001 -> E380 gg C256 E354 gg C001 -> E354 gg C256
External trouble alarm External alarm zone test report overdue
E383 gg C001 -> E383 gg C256 E307 gg C001 -> E307 gg C256
External tamper alarm External alarm zone failed self test
E110 gg C001 -> E110 gg C256 E570 gg C001 -> E570 gg C256
External fire alarm External isolate (bypass/shunt)
E120 gg C001 -> E120 gg C256 R570 gg C001 -> R570 gg C256
External raid alarm External deisolate
Note: The event code is changed to 572 for isolate or deisolate of tampers or off lines only.
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
4 Contact ID Reporting Codes
E145 gg C313 Keypad 17-64 tamper ('gg' = 17 to 64) E145 gg C319 Card reader 1-64 tamper ('gg' = 01 to 64)
E145 gg C314 16 I/O 17-64 tamper ('gg' = 17 to 64) E145 gg C320 Siren 1-64 tamper ('gg' = 01 to 64)
E145 gg C315 16 I/O 65-128 tamper ('gg' = 01 to 64, E145 gg C321 Remote arming station 1-64 tamper ('gg'
where 01 = 65) = 01-64)
E145 gg C316 16 I/O 129-192 tamper ('gg' = 01 to 64, E145 gg C322 Data gathering panel 1-15 tamper ('gg' =
where 01 = 129) 01-15)
E145 gg C317 16 I/O 193-256 tamper ('gg' = 01 to 64,
where 01 = 193)
E145 gg C318 Camera controller 5-64 tamper ('gg' = 05
to 64)
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 5
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
6 Contact ID Reporting Codes
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 7
E150 00 C610 Code check fail E150 00 C631 Exit bypass alarm
E150 00 C611 PIRs armed E150 00 C632 Personal attack alarm during comms fail
E150 00 C612 PIRs isolated E150 00 C633 Other alarm during comms fail
E150 00 C613 Final set to night not received E150 00 C634 System not reset
E150 00 C614 Film replaced E150 00 C635 Remote alarm panel restart
E150 00 C615 EEPROM error E150 00 C636 Configuration changed
E150 00 C616 General status report E150 00 C637 Final set at night
E150 00 C617 No master key E150 00 C638 Opening procedure ambush
E150 00 C618 No session key E150 00 C639 External EEPROM updated
E150 00 C619 Can't change mode - zone undefined E150 00 C640 Internal EEPROM updated
E150 00 C620 Invalid time/date E150 00 C641 Internal alarm isolated at mode change
E150 00 C621 DES encryption error E602 00 C642 Test mode timeout warning
E150 00 C622 Alarm lost E150 gg C643 Data gathering panel 1-15 DIP switch
E150 00 C623 No heartbeat acknowledge/response changed ('gg' is 01-15)
E150 00 C624 Master code updated E150 00 C644 Time and/or date changed
E150 00 C625 Second alert E150 gg C645 Remote arming station 1-64 invalid ID
E150 00 C626 Perimeter B auto-set time reached or PIN ('gg' is 01-64)
E150 00 C627 Perimeter B auto-unset time reached E150 gg C646 Remote arming station 1-64 duress alarm
E150 00 C628 Detectors in test ('gg' is 01-64)
E150 00 C629 Vault vibration detectors in test E150 gg C647 Remote alarm panel 1-8 dial-in
E150 00 C630 Service vibration detectors in test connection ('gg' is 01-08)
Opens and closes with user numbers: E150 gg C706 System reset / alarm cancel
E150 gg C707 Engineering mode
In the following messages, 'gg' is the area number 00-99
E150 gg C708 Restricted access mode
where 00 is area one.
E150 gg C709 Maintenance mode
E400 gg Unnn Open by user (day mode) E150 gg C710 Cleaner mode
R400 gg Unnn Close by user (night mode) E150 gg C711 Internal cleaner mode
E422 gg Unnn Duress open by user (day mode) * E150 gg C712 External cleaner mode
R422 gg Unnn Duress close by user (night mode) * E150 gg C713 ATM mode
E402 gg Unnn Area open by user E150 gg C714 Internal ATM mode
R402 gg Unnn Area close by user E150 gg C715 External ATM mode
E430 gg Unnn Late working on premises E150 gg C716 Sonalert mute
E431 gg Unnn Late working in vault E150 gg C717 Reset film frames
E432 gg Unnn Extended late working to all night E150 gg C718 Partial system reset
E404 00 C700 Late to open E121 gg C719 Duress mode
E404 00 C701 Late to close E150 gg C720 Management mode
E404 00 C702 Late close Vault E150 gg C721 Returned to day mode
E150 gg C722 Auxiliary ATM mode
* This message gets reported with EUROPLEX panel only. E150 gg C723 Forced zone window mode
E150 gg C724 Arming station menu mode
Modes: E150 gg C725 Courier mode
E150 gg C726 Out of hours access
In the following messages, 'gg' is the area number 00-99 E150 gg C727 Guard mode
where 00 is area one. E150 gg C728 Auxiliary access mode #1
E150 gg C729 Auxiliary access mode #2
E150 gg C702 General log on
E150 gg C730 Engineer lockout mode
E607 gg C703 Test mode
E150 gg C731 View log mode
E150 gg C704 Program ID mode
E604 gg C732 Fire test mode
E150 gg C705 Program closing time mode
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
8 Contact ID Reporting Codes
E350 00 C776 CPU card off line E350 00 C781 CPU card software downloaded okay
E350 00 C777 Cascade CPU card off line E350 00 C782 Card polling halted
E602 00 C778 System beacon E350 00 C783 Excessive message errors from a card
E350 00 C779 Backup CPU card off line E350 gg C784 CPU card queue full for too long ('gg' is
E350 00 C780 CPU card starting backup operation port number 1-8)
Note: Event codes are E140 for on, E570 for isolated, R140 for off and R570 for deisolated.
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 9
Note: GMS has an option to enable Supervisor commands in Port Parameters -> Advanced -> Message Filters
The alarms that will currently be supporting this feature are E810 gg C001 -> E810 gg C256
Door ajar and Door forced and any alarm point that is Fire alarm type
programmed as being of category "Environmental" (or) has
the flag checked in the Advanced Input config to enable E823 00 Cxxx
supervise. Forced Access / Alarm report, where "xxx" is Zone number
E826 00 Cxxx
Access Door propped open, where "xxx" is Zone number
E830 gg C001 -> E830 gg C256
Normal, night, general non-alarm, collector active, and
firealarm
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
10 Contact ID Reporting Codes
C111 00 O001 -> C111 00 O256 C510 gg O000 Change to secure (night mode)
Deisolate alarm point 1 -> 256
"gg" is the area number.
Output Commands:
Card Reader Commands:
C200 00 O000 -> C200 00 O063
Turn on output 1 -> 64 (000 is output one) C700 gg O001 -> C700 gg O064 Lock reader
C210 00 O000 -> C210 00 O063 C701 gg O001 -> C701 gg O064 Unlock reader
Turn off output 1 -> 64 C730 gg O001 -> C730 gg O064 Access reader
C220 00 O000 -> C220 00 O063 C731 gg O001 -> C731 gg O064 Secure/restore
Turn on momentary output 1 -> 64 (5 seconds) reader
"gg" is the time in seconds, "00" being the same as if no time
Mode Change Commands: is specified.
C500 gg O000 Change to access (day mode)
Go Off Line:
Create New Master Code:
C105 gg O000 "gg" is the time to stay off line in
minutes C113 00 O000
C108 gg O000 "gg" selects phone number to test C114 gg O000 "gg" is the area number
C110 00 O000
Dial Out To RTU:
C116 gg Onnn
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 11
Go On Line:
Create New Master Code:
C104 00 O000
C113 00 O000
Go Off Line:
Reset All RTU Alarms:
C105 gg O000 "gg" is the time to stay off line in
minutes C114 gg O000 "gg" is the area number
C109 00 O000
Dial Out To RTU:
Find New Controller Address: C116 gg Onnn
C110 00 O000 For this command, "gg" is the stay on line time in minutes
and "nnn" is the dial out line group number in the range 000-
125.
Change Line Card Line:
C111 gg O000 "gg" selects line to change to
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
12 Contact ID Reporting Codes
PIRs armed
Camera film low/out alarm
E150 00 C611.
E150 00 C550 - E150 00 C565.
PIRs isolated
Output on/off alarm
E150 00 C612.
E140 00 C800 - E140 00 863.
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 13
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
14 Contact ID Reporting Codes
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
Contact ID Reporting Codes 15
Internal alarm isolated at mode change Card reader locked / unlocked / accessed /
restored:
E150 00 C641.
E423 gg C870 - E423 gg C871.
Test mode timeout warning
Door forced alarm
E602 00 C642.
E150 gg C585.
Extended late working to all night
Door ajar alarm
E432 gg Unnn.
E150 gg C584.
Out of hours access
E150 gg C726.
Version 1.4 Modified 09/2005, Copyright © 2005 Pacom Systems Pty Ltd, All Rights Reserved
16 Contact ID Reporting Codes