755 Hydraulic Hand Pump

Description
The 755 Hydraulic Hand Pump develops 10,000 psi (68,950 kPa) and is intended
to be used with the following Greenlee conduit benders, tubing bender, and
punch driver.
Conduit Benders: model 777 Punch Driver: model 1732
model 880 Tubing Bender: model 782
model 882
model 882CB
Fill with Greenlee hydraulic oil or Mobil DTE-13 only.

Purpose of this Manual


This instruction manual is intended to familiarize operators and maintenance
personnel with the 755 Hydraulic Hand Pump. This manual should be kept
available to the operating and maintenance personnel.

SAFETY Immediate hazards which WILL, if not avoided, result in


ALERT severe personal injury or death.

SYMBOL
The symbol above is used to call your attention
to instructions concerning your personal safety. Hazards or unsafe practices which COULD, if not
Watch for this symbol. It points out important safety avoided, result in severe personal injury or death.
precautions. It means “ATTENTION! Become alert!
Your personal safety is involved!” Read the
message that follows and be alert to the possibility
of personal injury or death. Hazards or unsafe practices which COULD, if not avoided,
result in minor personal injury or property damage.

Safety is a critical factor in the design of Greenlee equipment. The best program starts with a safety-conscious
operator. The information highlighted in this bulletin describes operating practices for the benefit of the workers
who will use our equipment in their daily jobs. Comments from users are appreciated.

A person who has not read and does not understand all
operating instructions is not qualified to operate this tool.
Failure to read and understand safety instructions may
result in injury or death.

Greenlee Tools, Inc. 2 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

IMPORTANT SAFETY INSTRUCTIONS

Electric shock hazard: Inspect pump, hoses and couplers. Replace any
This is not an insulated tool. worn, damaged or missing components with
Greenlee replacement parts.
Contact with live circuits can result
in severe injury or death.

Wear eye protection when using


Skin injection hazard: this pump.
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
Follow the operating instructions and safety
• Hand-tighten all couplers
information supplied with the hydraulic ram or
completely before operating the
accessory.
pump. Do not use tools to tighten
the couplers. Failure to observe this warning could result in
severe injury or death.
• Do not use fingers or hands to
check for leaks while operating
the pump.
• Do not hold hose or couplers
while operating the pump.
• Release the hydraulic pressure • Use this tool for the manufacturer’s intended
before disconnecting hoses or use only.
couplers, and before servicing • Work in areas that are well-lit, uncluttered
the pump or accessory. and dry.

SAVE THESE INSTRUCTIONS


Additional copies of this manual are available upon request at no charge.

Greenlee Tools, Inc. 3 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

Operation Filling the Pump with Oil


1. Remove the dust cap. 1. Clamp the pump into a vise with the end cap (1)
2. Connect the hose to the bender or punch unit. upward. Loosen the set screw (26) and remove the
end cap.
Note: Hand-tighten the couplers completely.
Do not use tools. 2. Remove the cap screw (31) with O-ring (18) from
the reservoir follower (3). Remove the follower from
3. Twist the release knob (7) clockwise until it stops. the reservoir. Inspect both V-packings (28); replace
4. Pump the handle (9) until the bend or punch is them if they are worn or damaged.
complete. 3. Pour Greenlee hydraulic oil* into the reservoir until it
5. Twist the release knob (7) counterclockwise to is within 1-3/4" from the top.
release the hydraulic pressure. 4. Reinstall the reservoir follower.
6. Disconnect the hose from the bender or punch unit. 5. Turn the release knob (7) counterclockwise so the
Replace all dust caps. valve is open. Pump the handle (9) two or three
times.
6. Turn the release knob (7) clockwise so the valve is
closed. Pump the handle (9) two or three times.
7. Slowly turn the release knob (7) to
counterclockwise. This will allow any air trapped in
the pump block (10) or reservoir (8) to escape.
Note: Do this slowly to prevent the oil from suddenly
gushing up through the cap screw hole.
8. Repeat steps 5 through 7 one or two more times.
9. Inspect the O-ring (18) in the cap screw (31); replace
O-ring if it is worn or damaged.
10. Replace the cap screw (31) with O-ring (18) in the
follower (3). Hand-tighten the cap screw.
11. Wipe any excess oil from the outside of the reservoir
and replace the end cap (1). Tighten the set screw
(26).
* Order Greenlee hydraulic oil by the gallon
(part number 905 1059.3) or by the quart
(part number 905 0806.8).

Greenlee Tools, Inc. 4 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

Troubleshooting

PROBLEM PROBABLE CAUSE POSSIBLE REMEDY

Oil leak at coupler. Fitting loose or damaged. Tighten or replace fitting and/or coupler.

O-ring is worn or damaged. Replace O-ring.

Pump builds pressure, but ram Coupler is not tightened sufficiently, Hand-tighten coupler completely so
does not advance, or ram will and check balls are not engaged. check balls engage. Replace coupler
not return. if necessary.

Oil leak at OPEN/CLOSE O-ring and/or backup ring is worn Replace O-ring (18) and/or backup
release knob. or damaged. ring (17).

Release shaft is bent. Replace release shaft knob unit (7).

Oil leak at plunger. O-ring, backup ring and/or washer Replace O-ring (29), backup ring (15),
(Attached to handle.) are worn or damaged. and washer (16).

Injector packing nut is worn. Replace injector packing nut (6).

Oil leak at reservoir end. V-packing seal is worn or damaged. Replace two V-packing seals (28).

Cylinder wall damaged. Replace reservoir tube (8).

Can’t hold load or excessive


Ball in release knob leaking. Check seat for scratches or con-
pumping is required.
Discharge ball (20) or intake ball (22) tamination. Reseat ball or return to
below discharge ball (20) is leaking. an authorized Greenlee service center
for repair.

Can’t raise load with excessive Intake ball (22) below discharge ball (20) Check seat for scratches or con-
pumping but handle is rigid. is leaking. tamination. Reseat ball or return to
an authorized Greenlee service center
for repair.

Load on system causes handle Discharge ball (20) is leaking. Check seat for scratches or con-
to lift. tamination. Reseat ball or return to

an authorized Greenlee service center


for repair.

Greenlee Tools, Inc. 5 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

Exploded View

Greenlee Tools, Inc. 6 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

Exploded View (cont’d)

4 12 33 13 18 31

15
29
16

20 22 22 25 32 3 28 26 27 14

SECTION A-A

24

18
17

30

7
34

23

SECTION B-B

Greenlee Tools, Inc. 7 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

Pump Block Seat

ø .332 (Q) DRILL


ø 1/4 REAM

9/32 BALL SEAT

ø (11/64) REAM ø 0.238 (B) DRILL

7/32 BALL SEAT

ø .256 (F) DRILL


(NOTE DRILL ANGLE)

7/32 BALL SEAT

ø 9/64 DRILL
ø 5/32 REAM 15

Greenlee Tools, Inc. 8 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


755 Hydraulic Hand Pump

Parts List
UPC NO.
KEY 78-3310- PART NO. DESCRIPTION QTY.
1 501 5721.3 Cap, End.......................................................................... 1
2 501 5724.8 Lever, Injector.................................................................. 1
3 501 1716.5 Reservoir Follower (Replaces 501 5814.7)...................... 1
4 501 5725.6 Plunger............................................................................. 1
5 501 5726.4 Link, Lever....................................................................... 1
6 501 5727.2 Nut, Injector Packing....................................................... 1
7 501 8182.3 Release Unit (Includes Key Nos. 17, 18 and 22).............. 1
(Replaces 501 5728.0 and 501 6773.6 Units)
8 500 3467.7 Reservoir Tube (Replaces 501 5730.2)............................ 1
9 501 5731.0 Handle............................................................................. 1
10 501 5732.9 Block Weldment, Pump................................................... 1
11 501 5735.3 Pin, Fulcrum..................................................................... 2
12 500 3177.5 Washer, Sealing............................................................... 1
13 500 6111.9 Spring, Compression....................................................... 1
14 500 3422.7 Filter, Felt......................................................................... 1
15 905 1455.6 Ring, 9/16 x 3/4 Single Turn Scarf-Cut Back-Up............ 1
(Replaces 905 1173.5)
16 501 5736.1 Washer, Sealing............................................................... 1
17 905 3853.6 Ring, 1/4 x 3/8 Teflon Spiral Back-Up............................. 1
18 905 0418.6 O-Ring, 1/4 x 3/8 x 1/16.................................................. 2
19 905 0434.8 Ring, Retaining................................................................ 4
20 905 0436.4 Ball, 9/32 dia. Grade #1 Chrome Steel............................ 1
21 905 1174. 3 Grip, 1-1/16 ID x 1-3/8 OD x 5" Long Plastic.................. 1
22 905 0452.6 Ball, 7/32 Dia. Grade #1 Chrome Steel............................ 2
23 905 0385.6 O-Ring, 2-1/8 x 2-3/8 x 1/8 (Replaces 905 4770.5*)....... 1
24 905 0449.6 Pin, 5/16 x 1-1/4.............................................................. 1
25 905 0619.7 Screw, 5/16-18 NC x 1/4 Flat Point Socket Set.............. 1
26 905 0617.0 Screw, 1/4-20 NC x 1/4 Flat Point Screw Socket Set..... 1
27 905 0744.4 Ring, Retaining................................................................ 1
28 905 0745.2 V-Packing, 2-1/4 OD x 1-7/8 ID x 3/16............................ 2
29 905 0782.7 O-Ring, 9/16 x 3/4 x 3/32 (Replaces 905 4771.3*).......... 1
30 905 0807.6 Quick-Coupler, 3/8 NPTF................................................. 1
31 905 0558.1 Screw, 5/16-18 NC x 1/2 Fillister Head Cap.................... 1
32 905 0885.8 Pin, 1/4 x 3/8 Spiral......................................................... 1
33 905 1450.5 Screw, 3/8-24 NF x 1/2 Skt. Hd. Cap.............................. 1
(Replaces 905 0904.8)
34 905 1137.9 Elbow, 3/8-18 NPTF x 90° Street..................................... 1
37 905 0441.0 Oil, Greenlee Hydraulic................................................. 1 Qt.
502 0450.5 Decal, Product/Safety/Caution........................................ 1

Optional Parts
501 8272.2 Kit, Packing Repair

*Fluorocarbon O-rings used at factory as part of production process.

Greenlee Tools, Inc. 9 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070


4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070 USA Tel: 800-435-0786 Canada Tel: 800-435-0786 International Tel: +1-815-397-7070
©2019 Greenlee Tools, Inc. • An ISO 9001 Company Fax: 800-451-2632 Fax: 800-524-2853 Fax: +1-815-397-9247
www.greenlee.com

You might also like