100% found this document useful (1 vote)
312 views18 pages

Sampling Systems Catalog

This document describes liquid and gas sampling systems. It discusses general information about sampling systems and their applications. It also provides details about different series of sampling systems including LLS and LLSP series for liquid sampling without and with purging, respectively. The document discusses factors to consider when selecting containers for samples and provides an overview of HAVI's range of sampling system options.

Uploaded by

Vipul Panchal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
312 views18 pages

Sampling Systems Catalog

This document describes liquid and gas sampling systems. It discusses general information about sampling systems and their applications. It also provides details about different series of sampling systems including LLS and LLSP series for liquid sampling without and with purging, respectively. The document discusses factors to consider when selecting containers for samples and provides an overview of HAVI's range of sampling system options.

Uploaded by

Vipul Panchal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

Spreaded over 50,000 Sq.

Ft

Received GOLD Award


for Made in India Export Substitue
Product

Few of our Approvals and Esteemed Customers


Introduc on

General
HAVI Samplers are used to collect samples of Liquid or Gas from a Pipeline, Tank or a System. The Samples are collected

in a Sampling Bomb and then transported for analysis in a Laboratory.

We offer a wide range of Sampling Systems sui ng to the applica on requirement. All levels of sophis ca on are

available right from Manual Sampling to Complex mul Sampling Bomb Systems. Toxic, flammable and corrosive medias

are safely sampled using systems with all we ed parts in PTFE, PFA, Hastelloy and other exo c materials. Sampling

systems are also available in 316L Stainless steel for less corrosive du es.

Tradi onal methods of sample taking have been rather crude and rudimentary. They have included open ended valves

which have been allowed to flow into effluent drains to run clear any old product before flowing representa ve enough

to take a sample. Or taking a first sample and discarding it before a second representa ve sample is taken. These

tradi onal methods incur a lot of costs and can be environmentally unfriendly. Operator exposure is of great importance

too and may require the use of expensive safety equipment and clothing. By using a representa ve sample the operator

need only take the volume of sample required to carry out their tests, typically this can be only a few millilitres. Meaning

far less spent sample media to dispose of saving addi onal costs.

Applica on
• To Validate Process Condi ons of a System

• To ensure that the End Customer gets the Product mee ng to the required Quality specifica ons

• To ensure Quality of End Product during Custody Transfer

• For online Monitoring of the System, Con nuous flow Samplers are the best op on.

ENGINEERED TO ORDER SAMPLERS


EASY TO USE AND MAINTAIN SYSTEMS
ENTIRE SYSTEM TESTED TO FET AS PER MESC CPECIFICATIONS
BEST FABRICATION WORKMANSHIP

1
Introduc on

Sampling System Selec on


The basic Engineering of a Sampling System is to safely capture the sample from the Process line or a System. During

this, it is very essen al to ensure that the collected sample replicates the actual contents present in the Process. Variety

of Sample’s configura on are manufactured based on the type and cri cality of the sample to be collected.

First important thing is to select the type of Container for the collected Sample. The Chart below will help you to iden fy

the right Container for your Sample.

Sample type Pressurised Non Pressurised


Liquid Container Container / Bo le
Gas Container Container
Vapour Container Container

Range
Broadly classifying HAVI offers Sampling System for collec on of Gases and Liquids. Depend on the applica on

requirement, addi onal features such as Purge Line to clean the residual, Pressure Relief Valve, Con nuos Flow are

incorporated in the System. Sampling Systems are Engineered based on the Customer requirement and hence the below

range is to cover the variety of op ons available with HAVI.

Series Descrip on
LLS Sampling System for Liquid without Purging

LLSP Sampling System for Liquid with Purging

GS Sampling System for Gas / Vapour without Purging

GSP Sampling System for Gas / Vapour with Purging

CLS Online Sampling System for Liquid without Purging and Con nuous Flow

CLSP Online Sampling System for Liquid with Purging and Con nuous Flow

CGS Online Sampling System for Gas / Vapour without Purging and Con nuous Flow

CGSP Online Sampling System for Gas / Vapoor with Purging and Con nuous Flow

2
Custom made Coolers & Sampling System

Sample Cooler
Customer: IOCL
Project: EPCM Services for
BS-VI & CRU Project

Sampling System
Customer: IOCL
Project: BS-VI & CRU Project

Closed Flow through Sampling


Apparatus for Gas, Toxic Liquids,
or High Vapor Pressure Liquids

3
LLS Series

LLS Series Liquid Sampler without Purge


This Sampling System are basic without Purge used for Liquid collec on for general applica ons.

These are recommended for Fluids that are Non Toxic and does not have tendency to se le in the lines a er sample is

collected. These are also recommended for Fluid that returns to Flare line.

FRONT VIEW

VENT

OUTLET

INLET
SAMPLE Mode

Process Fluid passes from Inlet through the Sampling Cylinder, Quick
Connectors, Hose and other Fittings to the Outlet. The Fluid will ow as long
as the Handle is in this Position.

BACK VIEW
VENT

OUTLET

INLET

VENT Mode

When the Sampling Cylinder is lled completely, the Tight Shut Valves on
Cylinder are closed. Handle is turned to Vent position. Inlet and Outlet is
Isolated and the uid present in the line passes through Vent.

When handle is in OFF Position, Inlet, Outlet and Vent are stopped.

4
LLSP Series

LLSP Series Liquid Sampler with Purge


This Sampling System are basic with Purge used for Liquid collec on for general applica ons. Purging can be done using

a Gas or a Solvent to flush the Lines before or a er the Sampling is done.

These are recommended for Fluids that are Non Toxic and have tendency to se le in the lines a er sample is collected.

These are also recommended for Fluid that returns to Flare line.

FRONT VIEW Process Fluid passes from

PURGE

OUTLET

INLET

VENT
Inlet through the Sampling
Cylinder, Quick Connectors,
Hose and other Fittings to the
Outlet. The Fluid will ow as
long as the Handle is in this
Position.

SAMPLE Mode

When the Sampling

PURGE

OUTLET

INLET

VENT
Cylinder is lled completely,
the Tight Shut Valves on
Cylinder are closed. Handle
is turned to Vent position.
BACK VIEW Inlet and Outlet is Isolated
and the uid present in the
line passes through Vent.

VENT Mode

With the Vent Valve ON,


PURGE

INLET

VENT
OUTLET

Turn the Purge Valve to ON


position. Purge will be
activated to ush the lling
lines from the opposite
direction.

When handle is in OFF


Position, Inlet, Outlet and
Vent are stopped.
PURGE Mode

5
GS Series

GS Series Gas Sampler without Purge


This Sampling System are basic without Purge used for Gas collec on for general applica ons.

These are recommended for Gases that are Non Toxic and does not have tendency to se le in the lines a er sample is

collected. These are also recommended for Fluid that returns to Flare line.

VENT

INLET

OUTLET
FRONT VIEW

SAMPLE Mode

Process Fluid passes from Inlet through the Sampling Cylinder, Quick
Connectors, Hose and other Fittings to the Outlet. The Fluid will ow as long
as the Handle is in this Position.

VENT

INLET

OUTLET
BACK VIEW

VENT Mode

When the Sampling Cylinder is lled completely, the Tight Shut Valves on
Cylinder are closed. Handle is turned to Vent position. Inlet and Outlet is
Isolated and the uid present in the line passes through Vent.

When handle is in OFF Position, Inlet, Outlet and Vent are stopped.

6
GSP Series

GSP Series Gas Sampler with Purge


This Sampling System are basic with Purge used for Gas collec on for general applica ons. Purging can be done using a

Gas or a Solvent to flush the Lines before or a er the Sampling is done.

These are recommended for Gases that are Non Toxic and have tendency to se le in the lines a er sample is collected.

These are also recommended for Gas that returns to Flare line.

PURGE
VENT

INLET

OUTLET
FRONT VIEW Process Fluid passes from
Inlet through the Sampling
Cylinder, Quick Connectors,
Hose and other Fittings to the
Outlet. The Fluid will ow as
long as the Handle is in this
Position.

SAMPLE Mode

PURGE
VENT

INLET

OUTLET
When the Sampling
Cylinder is lled completely,
the Tight Shut Valves on
Cylinder are closed. Handle
is turned to Vent position.
BACK VIEW Inlet and Outlet is Isolated
and the uid present in the
line passes through Vent.

VENT Mode
PURGE
VENT

OUTLET

INLET

With the Vent Valve ON,


Turn the Purge Valve to ON
position. Purge will be
activated to ush the lling
lines from the opposite
direction.

When handle is in OFF


Position, Inlet, Outlet and
Vent are stopped. PURGE Mode

7
CLS Series

CLS Series Con nuous Flow Liquid Sampler without Purge


This Sampling System has the feature of Con nuous Flow of Fluid from Inlet to Outlet during Vent and Off posi on. This

System is without Purge and are used for Liquid collec on for general applica ons.

These are recommended for Fluids that does not have tendency to se le in the lines a er sample is collected. These are

also recommended for Fluid that returns to Flare line.

FRONT VIEW

VENT

OUTLET

INLET
SAMPLE Mode

Process Fluid passes from Inlet through the Sampling Cylinder, Quick
Connectors, Hose and other Fittings to the Outlet. The Fluid will ow as long
as the Handle is in this Position.

BACK VIEW
VENT

OUTLET

INLET

VENT Mode

When the Sampling Cylinder is lled completely, the Tight Shut Valves on
Cylinder are closed. Handle is turned to Vent position. Inlet and Outlet will ow
continuously and the uid present in the line passes through Vent.

When handle is in OFF Position, Inlet & Outlet Flow is not haulted.

8
CLSP Series

CLSP Series Con nuous Flow Liquid Sampler with Purge


This Sampling System has the feature of Con nuous Flow of Fluid from Inlet to Outlet during Vent and Off posi on. This

System is with Purge and are used for Liquid collec on for general applica ons.

These are recommended for Fluids that have tendency to se le in the lines a er sample is collected. These are also

recommended for Fluid that returns to Flare line.

FRONT VIEW Process Fluid passes from

PURGE

OUTLET

INLET

VENT
Inlet through the Sampling
Cylinder, Quick Connectors,
Hose and other Fittings to the
Outlet. The Fluid will ow as
long as the Handle is in this
Position.

SAMPLE Mode

When the Sampling

PURGE

OUTLET

INLET

VENT
Cylinder is lled completely,
the Tight Shut Valves on
Cylinder are closed. Handle
is turned to Vent position.
BACK VIEW Inlet and Outlet will ow
continuously and the uid
present in the line passes
through Vent.

VENT Mode

With the Vent Valve ON,


PURGE

OUTLET

INLET

VENT

Turn the Purge Valve to ON


position. Purge will be
activated to ush the lling
lines from the opposite
direction.

When handle is in OFF


Position, Inlet & Outlet Flow
is not haulted.

PURGE Mode
9
CGS Series

CGS Series Con nuous Flow Gas Sampler without Purge


This Sampling System has the feature of Con nuous Flow of Gas from Inlet to Outlet during Vent and Off posi on. This

System is without Purge and are used for Liquid collec on for general applica ons.

These are recommended for Gases that does not have tendency to se le in the lines a er sample is collected. These are

also recommended for Fluid that returns to Flare line.

VENT

INLET

OUTLET
FRONT VIEW

SAMPLE Mode

Process Fluid passes from Inlet through the Sampling Cylinder, Quick
Connectors, Hose and other Fittings to the Outlet. The Fluid will ow as long
as the Handle is in this Position.

VENT

INLET

OUTLET
BACK VIEW

VENT Mode

When the Sampling Cylinder is lled completely, the Tight Shut Valves on
Cylinder are closed. Handle is turned to Vent position. Inlet and Outlet will ow
continuously and the uid present in the line passes through Vent.

When handle is in OFF Position, Inlet & Outlet Flow is not haulted.

10
CGSP Series

CGSP Series Con nuous Flow Gas Sampler with Purge


This Sampling System has the feature of Con nuous Flow of Fluid from Inlet to Outlet during Vent and Off posi on. This

System is with Purge and are used for Liquid collec on for general applica ons.

These are recommended for Fluids that have tendency to se le in the lines a er sample is collected. These are also

recommended for Fluid that returns to Flare line.

INLET

OUTLET

PURGE
VENT
FRONT VIEW Process Fluid passes from
Inlet through the Sampling
Cylinder, Quick Connectors,
Hose and other Fittings to the
Outlet. The Fluid will ow as
long as the Handle is in this
Position.

SAMPLE Mode

INLET

OUTLET

PURGE
VENT
When the Sampling
Cylinder is lled completely,
the Tight Shut Valves on
Cylinder are closed. Handle
is turned to Vent position.
BACK VIEW Inlet and Outlet will ow
continuously and the uid
present in the line passes
through Vent.

VENT Mode
PURGE
VENT

INLET

OUTLET

With the Vent Valve ON,


Turn the Purge Valve to ON
position. Purge will be
activated to ush the lling
lines from the opposite
direction.

When handle is in OFF


Position, Inlet & Outlet Flow
is not haulted.
PURGE Mode

11
Sample Probes

HAVI manufactures Custom made Sampling Probe Assembly to the Customer Specifica ons. These Solu ons comes in

Manual Retractable Assembly and Screwed or Welded Probe to a Block & Bleed Valve or a Ball Valve. Probes are used to

extract Sample from the Center third of Pipe Line.

These Probes comes in various Material Op ons and sizes.

Retractable Probe Assembly

Welded / Screwed Probe with Valve

12
Sampling Cylinders

General
Sampling Cylinders comes in various sizes based on the volume of the Sample to be collected. Material selec on of

Cylinders depends on the type of Sample. HAVI manufactures various sizes of Sampling Cylinder with different

configura ons.

• Available with or without Purging Tube

• Op on of Handle on the Cylinder

• Choice of Quick Connectors type

• Comes with Tight Shut Needle Valves

• Op on of Outage Tube to provide Vapour space

• Inlet & Outlet size of 1/4" and 1/2"


Dia A

Volume A B
150 ML 140 2" Pipe

300 ML 300 2" Pipe

400 ML 350 2" Pipe

500 ML 410 2" Pipe

1000 ML 340 3" Pipe

Note: Custom size of Cylinders based on the Volume can also be Designed and manufactured

13
Notes
Related Products

Prefabricated Closed-couple Modular


Hook-ups DBB Hook-up Manifolds

Monoflange Manifold Tube & Pipe


Valves Valves Fi ngs

You might also like