AACORP0736 UAT ActronAir Website Commercial Packaged Pages v4 Herc

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

The brains and brawn redefining

air conditioning efficiencies.


Hercules is the most advanced, energy efficient packaged
unit ever made in Australia. The first packaged system to have
twin inverter compressors, it’s big in lots of ways. Rated to
a superior operating range, Hercules can handle the most
extreme conditions Australia can throw at it, designed for large
spaces such as warehouse stores, shopping centres, airport
terminals, and car showrooms. But along with all that brawn
comes some very brainy energy efficient thinking.
ActronAir was the first air conditioning company to
use inverter technology in a large-scale commercial air
conditioner, and it allows superb flexibility.

Guaranteed Uses just Over 46%


to perform 25 amps at more efficient
up to 50°C start-up
than the minimum BCA
compliant system

Nett (Rated) Capacity - Cooling - Three Phase

135.00 kW 187.50 kW
PKV1400T PKV2000T

That ’s be tter. That ’s Actron .


Features
» Vertical Discharge – Condenser air » In-built controls solution
» High efficiency EC fan technology » Dual control capability for enhanced
» BMS Option user access
» Powder coated outdoor panels » R410A refrigerant
(60~80 microns) » Multiple Handing Options
» Blue fin epoxy coated indoor + » Foil face polyethylene insulation
outdoor coil protection » Sloped indoor coil drain pan
» E-Prime™ Evaporator Drain Tray » Economy cycle control logic
» Electronic Expansion Valve (EEV) » High Static condenser fans 80-120Pa
» Dual inverter compressors

Compressor
» Variable Capacity Scroll with Inverter Drive

Power
» Three phase – 400V / 3Ph + N / 50Hz

Controller Options
» CP05 »C
 M100
» CL01 »G
 roup Control
»C P10

Connectivity & Sensor Options


» BMS Compatible – MODBUS and BACNET » Temperature Sensor – Bead or
» Humidity Sensor – Duct Mount or Surface Mount
Surface Mount » CO2 Sensor

Additional Options
» Economy Cycle Dampers and Motors » Reheat
» Coil Coat Indoor & Outdoor

*Requires Group Control

That ’s be tter. That ’s Actron .


Technical Specifications - Package Unit Variable Capacity 140-195kW

Technical Information
Three Phase
PKV1400T PKV2000T
PACKAGE MODEL
Maximum Capacity Maximum Capacity
1
Total (Gross) Capacity (kW) Cooling (Min - Max) 140.00 (35.50 -140.00) 195.50 (49.00 - 195.50)
(AS/NZS3823.1.2) Heating 147.00 202.10
Nett (Rated) Capacity (kW) Cooling 135.00 187.50
(AS/NZS3823.1.2) Heating 152.50 210.00
Nett (Rated) Input Power (kW) Cooling 44.84 61.75
(AS/NZS3823.1.2) Heating 39.50 59.60
2
EER Rated (AS/NZS3823.1.2) Cooling 3.01 3.04
3
COP Rated (AS/NZS3823.1.2) Heating 3.86 3.52
Power Supply (V / Ph / Hz) 400V / 3Ph + N / 50Hz
Rated Amps (AS/NZS3823.1.2) 71.6 86.0
Full Load Amps (AS/ NZS3823.1.2) 89.9 117.0
4
Circuit Breaker Amps 100.00 125.0
IP Rating IP44
Type / No. per Unit Variable Capacity Scroll with Inverter Drive / 2
Compressor
Starting Method Soft Start
No. of Refrigeration Circuits/Capacity Range 2 / Variable
Refrigerant R410A
Outdoor Variable Speed ECM / Direct Drive Axial Fan x 4
Fans (Type x Number per unit)
Indoor Variable Speed ECM / Direct Drive Backward Curve Plug Fan x 4
Maximum 8880 11200
Airflow Indoor (l/s) Nominal 7400 9900
Minimum 5920 7920
Maximum Airflow 225 460
External Static Pressure (Pa) at:
Nominal Airflow 465 500
Depth 5250
Unit Dimensions (mm) Height 2360
Width 2300
5
Nominal Weight (kgs) 2716 3012
6
Sound Pressure Level (dBA) Outdoor (high/maximum) 59.1 / 66.2 66.2 / 66.2
7
Sound Power Level (dBA) Outdoor (high/maximum) 76.1 / 83.2 83.2 / 83.2
BCA Compliant Yes Yes
9
Demand Response Capability (AS4755.3) Capable

Foot Notes 1-8 Important Notes:


1. Based on unit rating excluding indoor fan kW. • The Local Electricity Supply Authority may require limits on - starting current, running current
and voltage drop, please check prior to purchase.
2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities
3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating). may decrease the rated nett values.
4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details. • Specifications subject to change without notice.
5. Refer to Catalogue Unit Weight Distribution Guide section for details of weight points.
6. 
Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m Rated Conditions:
perpendicular to the coil side of the condenser.
7. 
Determination of Sound Power Levels of Noise Sources, AS1217.2 - Precision Methods for Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB
Broad-Band Sources in Reverberation Rooms. Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
8. 
When Demand Response capability is chosen, the air conditioner will fully comply with AS4755.3
in the following modes: DRM 1, 2, 3.
Warranty:
For full terms and conditions of ActronAir warranty, please refer to warranty terms document -
www.actronair.com.au

That ’s be tter. That ’s Actron .


Technical Specifications

Control Options and Features


PACKAGE MODEL PKV1400T PKV2000T
CP10 Control Interface with LCD Display for System Operation Standard Standard
Automatic / Manual Operation Standard Standard
7 Day Programmable Time-Clock Standard Standard
Bi-Flow Electronic Expansion Valve (EEV) Standard Standard
Compressor Discharge Temperature Control Standard Standard
Adjustable Indoor Fan Airflow Setpoint Standard Standard
Indoor Coil Anti-Freeze Protection Standard Standard
Return Air Offset Standard Standard
High and Low Pressure Protection Standard Standard
Three Phase protection on all Motors Standard Standard
Alarm Fault Data Logger Standard Standard
BMS 485/TCP-IP Compatibility (accessory) Optional Optional
CP05 / CP10 Control Interface (Available as Dual Option) Optional Optional
CO2 Sensor for economy cycle (accessory) Optional Optional
Humidity Sensor for economy cycle (accessory) Optional Optional
Group Control Interface and Controller (accessory) Optional Optional

Field Information
Refrigerant Factory Charge - (g) 19,500 & 19,500 28,000 & 28,000
Condensate Drain Connection Indoor Section 31.8 mm (1-1/4”) Ø BSP Female Socket
- Size/Type Outdoor Section 31.8 mm (1-1/4”) Ø BSP Female Socket
Supply Duct W x L - (mm) 553 x 1953
Air Duct Connection
Return Duct W x L - (mm) 803 x 1953

Variations
B - Floor Mesh Supply Air - Down Supply Air Optional Optional
C - Floor Mesh Return Air - Bottom Return Air Optional Optional
E - Economiser without Spill Air
8
Optional Optional
F - Economy Control 3rd Party Components Optional Optional
G - Outside Air Auto
8
Optional Optional
H - Outside Air Manual
8
Optional Optional
K - Additional Coil Coat Protection (Outdoor Section) Optional Optional
L - Additional Coil Coat Protection (Indoor Section) Optional Optional
M - Economy Cycle with Spill Air
8
Optional Optional
W - Reheat for RH Control* (Blue Fin + Complete Coil treatment) Optional Optional
X - IP55 Rated Optional Optional

That ’s be tter. That ’s Actron .