PA18CLD
PA18CLD
Diffuse-reflective
Type PA18CLD0.T, AC, PBTP-housing
• Range: 400 mm adjustable
100, 200 or 400 mm fixed
• Modulated, infrared light
• Supply voltage: 20 to 250 VAC
• Output: 500 mA SCR
• Make or break switching function, LED indication
• High immunity to ambient light
• Cable and plug versions
Type Selection
Housing Rated Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating SCR/Cable SCR/Plug SCR/Cable SCR/Plug
dist. (Sn) Make switching Make switching Break switching Break switching
Specifications
Rated operating dist. (Sn) Min. operational current (Im) 10 mA
Adjustable Up to 400 mm OFF-state current (Ir) Max < 5 mA, typ. 2.6 mA
Fixed 100, 200 or 400 mm
Voltage drop (Ud) Max ≤ 10 V, typ. 7 VAC
Reference target:
Kodak test card R27, white, Protection Transients
90% reflectivity Transient voltage Max 1 kV/0,5 J
Size: Sn < 400 mm 100 x 100 mm Light source GaAlAs LED, 880 nm
Sn ≥ 400 mm 200 x 200 mm Light type Infrared, modulated synchronized
Sensitivity Sensing angle ± 25° at 1/2 range
Adjustable type only 270° turn potentiometer, Ambient light Max 10'000 lux
Temperature drift 0.4%/K Operating frequency (f) 20 Hz, light/dark ratio 1:2
Hysteresis (H) Response time
(Differential travel) 3 to 20%, OFF-ON (tON) ≤ 20 ms
Rated operational volt. (UB) 20 to 250 VAC, ON-OFF (tOFF) ≤ 30 ms
45 to 65 Hz Power ON delay (tV) Typ. 100 ms
Output current (AC12, AC140) Indication function Dark (NC) or light (NO) switching
Continuous (Ie) ≤ 500 mA Output ON LED, yellow
Short-time (I) ≤ 3 A, max. 20 ms
Specifications (cont.)
Environment Housing material
Overvoltage category III (IEC 60664/60664A; 60947-1) Body PBTP, grey thermoplastic
Pollution degree 3 (IEC 60664/60664A; 60947-1) polyester
Degree of protection IP 67 (IEC 60529; 60947-1) Front Luran®, black
Temperature Cable end Polyester, black
Operating -20° to +60°C (-4° to 140°F) Nuts Reinforced nylon
Storage -30° to + 70°C (-22° to 158°F) Connection
Vibration 10 to 150 Hz, 0.5 mm/- Cable Grey, 2 m, 2 x 0.5 mm2,
7.5 g (IEC 60068-2-6) oilproof PVC,
Shock 2 x 1 m 100 x 0.5 m Plug M12 x 1
(IEC 60068-2-32) Cables for plug (M6) CON.6A-... series
Dielectric voltage 1600 VAC Weight
(IEC 60364-4-41) Cable version 105 g
Plug version 22 g
Approvals UL, CSA
CE-marking Yes
Operation Diagram
Power supply
Object present, light received
Output ON: Make switching (NO) Tv
Tv
Break switching (NC)
3 BU
2 BN
3 BU
M12 x 1
Installation Hints
To avoid interference from inductive voltage/ Relief of cable strain Protection of the sensing face Switch mounted on mobile carrier
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled A proximity switch should not serve as Any repetitive flexing of the
mechanical stop cable should be avoided
Detection Diagrams
Sensor Sensor
Y Y
X (inch) X (inch)
R27 R27
Kodac test card 0.8 Kodac test card 2 4 6 8 10
1.6 2.4 3.1 3.9 4.7
30.0 1.2 60.0 2.4
(mm)
(mm)
0.0 0.0 0
(inch)
0.0
(inch)
-10.0 -0.4 -20.0 -0.8
Sensor
Y (inch)
X R27
Kodac test card 4 8 12 16 20
60.0 2.4
40.0 1.6
20.0 0.8
(mm)
0.0 0
(inch)
-20.0 -0.8
-40.0 -1.6
-60.0 -2.4
0.0 100.0 200.0 300.0 400.0 500.0
PA18CLD04.. Distance (mm)