Keyence GV Laser Sensor IM
Keyence GV Laser Sensor IM
The laser emission stops when an emission stop (purple line) signal is input (for
20 ms or longer). The emission stops while the signal is input. The laser beam is
emitted a maximum of 20 ms after the signal input is canceled. The control
output functions according to the detection value even while laser emission
stop is input.
Digital CMOS Laser Sensor
GV Series
Laser warning labels
The following diagrams show the type and position of laser warning labels
according to the GV Series.
GV-H45(L)/GV-H130(L) GV-H450(L)/GV-H1000(L)
Instruction Manual Aperture label
Aperture label Aperture label
Read this manual before using the software in order to achieve maximum
performance. Aperture label
Keep this manual in a safe place after reading it so that it can be used at any time.
Note The displayed values indicate guidelines for distances and should not
be used in the actual applications for measurement.
Laser
Safety Precautions transmitter Laser
transmitter
z Aperture label
BA
NK BA
SEL NK
TIM SEL
serie
MOD
E
TIM
CLP
MOD
E
s serie
s
DATUM 1spot
LASER
1
OUT SEL
2
SET 1
2 MODE
TIM
BANK CLP
series
1 GV-IM-E
Mounting and Wiring the Sensor Amplifier Connecting and Mounting the Sensor
Head
Mounting the sensor amplifier
Sensor head part names
Mounting the GV-21/GV-21P (main unit)
1 Align the claw at the bottom of the (3)
Laser receiver Mounting area
main body with the DIN rail. While
pushing the main body in the LASER
direction of the arrow 1, slant it in the (Laser radiation
(2) emission indicator)
direction of the arrow 2.
OUT
(1)
(Control output
2 To dismount the sensor, raise the indicator)
main body in the direction of the
1spot
arrow 3 while pushing the main body (Spot reflection
in the direction of the arrow 1. indicator)
When using the amplifier mounting bracket
Mounting area
(OP-76877) (sold separately), mount it as
shown in the diagram to the right. Laser Connector
• When connecting multiple amplifiers (expansion units), first 2 Turn the round part of the
check to make sure that the power is turned off to all of the connector clockwise until a
main and expansion units. Connecting the units with the clicking sound is heard to lock
power turned on may cause damage to the units. it.
• Push the amplifiers (expansion units) as far as possible into Locked
CAUTION the main unit. If they are connected at a slant or not inserted
securely, the units may be damaged.
• Only GV Series amplifier can be connected (DL Series cannot
be connected). Connecting other amplifiers may cause
damage to the units.
Note When shortening the sensor head cable, follow the instructions given in
the "Sensor Head Connector Assembly Manual" included with the sensor
Note Expansion units with different output types (such as a PNP output main head.
unit to an NPN output expansion unit) cannot be connected together.
Insulating sheet
2 Install the amplifiers (expansion units) on the DIN rail. Sensor head
For more information about mounting, see "Mounting the GV-21/GV-21P (main
unit)".
Amplifier wiring
• Stable detection • Incorrect values
The following information shows the I/O cable. even on uneven can be detected
For more information about the I/O circuit, see page 9 of this Instruction Manual. areas. on the uneven
areas.
Brown*1 *1 GV-22/GV-22P (expansion unit) do not
Blue*1 10-30 V DC have brown or blue lines. Power is supplied
to the expansion units through GV-21/GV-
Black 21P (main unit).
Control output 1
White *2 The external input switches as shown
Control output 2
Pink*2 below depending on the amplifier
External input OPTIONAL settings.
Purple
Laser emission • oFF ......... Input off
stop input • SFt .......... External shift
• bnK ......... Bank switching
• tim ........... Timing input
GV-IM-E 2
Example When using sensor head GV-H130
Sensor Amplifier
Sensor amplifier part names
Spot reflection (1spot) indicator*2 Distance
Reference surface (DATUM) detection (green)
indicator*1 (red) Current value display 0mm
Current value
Setting value display (green) (red) Arrow
buttons 55mm 750 Minimum detection distance
DATUM 1spot
Laser radiation emission LASER
indicator (green) 1 130mm 0 Maximum detection distance
Output status indicator OUT SEL
2
(red)
SET 1
2 TIM
MODE For example, when using the defaults with the setting value (green) at 500, the
[SET] button comparator output turns on when the current value is 500 or greater and turns off
BANK CLP
series when it is less than 500.
If multiple reflection (when multiple peaks of received light intensity occurs due to
Channel No. indicator (green) CLP function indicator*3 [MODE] button diffuse reflection) occurs during F-1, F-2, or A-1 modes, the value immediately before
(red) the current value is held.
Bank input indicator (green) LED bar Timing input indicator*4 (red)
z Setting value
*1 The reference surface (DATUM) detection indicator lights up when performing The following table shows the default setting values for each channel.
reference surface detection. For more information, see "Reference surface
detection (DATUM) method (Application)" on page 5 of this Instruction Manual. Operation Default value
Item
*2 The spot reflection indicator lights up during normal detection and turns off during mode GV-H45 (L) GV-H130 (L) GV-H450 (L) GV-H1000 (L)
multiple reflection (when multiple peaks of received light intensity occurs due to Control output 1 (black)
diffuse reflection), insufficient light intensity, and when the target is out of the 150 500 200 500
F-1, A-1, (Channel 1 lit)
detection range. A-2 Control output 2 (white)
*3 For more information about the CLP (clamp) function indicator, see "4. Clamp 125 400 150 400
(Channel 2 lit)
function setting" on page 8 of this Instruction Manual.
Control output 1 (black) HIGH
*4 For more information about the timing input indicator, see "8. External input 150 500 200 500
(Channel 1 lit)
setting" on page 8 of this Instruction Manual.
Control output 1 (black) LOW
100 300 100 300
(Channel 2 lit)
F-2
Control output 2 (white) HIGH
Main screen (Channel 1 flashing)
125 400 150 400
Control output 2 (white) LOW
75 200 50 200
The main screen can be switched between "Current/setting value display" and "Peak/ (Channel 2 flashing)
bottom value display". The main screen can be switched even during keylock.
z Peak/bottom values
DATUM
Peak value: Resets when the detection value exceeds the setting value
and holds the maximum value (peak value) until the detection
value falls below the setting value again.
SET 1
SET 1 SET 1
2 MODE 2 MODE
or
Channel No. indicators Peak value (green) Bottom value (red)
Note When the channel No. 1 indicator is lit, the control output 1 (black line)
setting value is displayed. When the channel No. 2 indicator is lit, the control
output 2 (white line) setting value is displayed.
Operations are different in F-2 mode. (See page 5 of this Instruction
Manual.)
Note The displayed values indicate guidelines for distances and should not be
used in the actual applications for measurement.
3 GV-IM-E
Using Basic Operations
Configuring the Sensitivity Setting and
Operation Mode
Configure the sensitivity setting in F-1 mode (with the default settings).
When using the F-2 mode, the channel No. indicator switches in the following order
each time the [MODE] button is pressed.
MODE
Press once.
1
MODE
1
MODE MODE
1
Press once. Press once. 1 Press once.
2 2 2
2
Control output 1 Control output 1 Control output 2 Control output 2
(black) HIGH setting (black) LOW setting (white) HIGH setting (white) LOW setting
value value value value
• Channel No. 1 • Channel No. 2 • Channel No. 1 • Channel No. 2
indicator lights up indicator lights up indicator flashes indicator flashes
GV-IM-E 4
z Edge hold mode (A-1 mode) Configuring the sensitivity setting for distance
This operation mode is suitable for detecting workpieces on a conveyer or
detecting workpieces with waving backgrounds. It ignores slow distance detection method
changes and only detects workpieces (sudden changes in height).
When height differences greater than the setting value are detected (low areas 2-point calibration (operation modes: F-1, A-1, A-2)
become high), the value at the detected time are held and displayed, and control
output starts. 1 Press the [SET] button once without a
If the difference is small and does not exceed the setting value, the display stays as 0. workpiece in place.
When height differences greater than the setting value are detected (high areas The current value without the workpiece is
become low), detection value becomes 0 and control output is stopped. read.
Note • When edge hold mode (A-1 mode) is selected, edge hold mode only
operates on channel 1. Channel 2 operates under distance Reference If there is very little difference between the values obtained in Step 1
measurement mode (F-1 mode). and Step 2, then "---" flashes in the setting value display area after
• If the edges are gentle (such as spherical or tilted workpieces), this calibration is complete. The setting value is still updated.
mode may not be able to detect workpieces or may output the value
incorrectly.
• Send the workpiece past the sensor head so that the area for Maximum sensitivity setting (operation modes: F-1, A-1, A-2)
detecting height differences is parallel to the sensor head. See
"When detecting uneven workpieces" (page 3). 1 Press and hold the [SET] button for at least three seconds without a
workpiece in place.
Reference • When a detection value is being held, press and hold the [Up] and
[Down] arrow buttons at the same time to set the current value to 0
(regardless of the shift target value) and to turn off output. The 2 Release the [SET] button when "SEt" flashes on the display.
current value for channel 2 changes to 0 as well. This concludes maximum sensitivity calibration and the sensor returns to the
• If the external input function is set to "SFt" and the external input detection state.
(pink line) is turned on, the control output turns off and the current
value becomes 0. (When channel 2 is selected, the current value
becomes 0 as well. Turning the laser emission stop input on and off Full auto calibration (operation modes: F-1, A-1, A-2)
performs a similar action, but it only changes the current value of
the channel to 0.) This method performs calibration while the target is moving.
Reference surface detection (DATUM) method (Application) 1 Press and hold the [SET] button for at
least three seconds while the target
This method memorizes the background (reference surface) and uses it to
workpiece is passing through the
perform comparator output when there is a workpiece (when the state differs
from the reference surface).
detection area for the sensor.
The sensitivity is set according to the
The reference surface detection (reference surface calibration) can only be used
detection value while the [SET] button is
on Channel 1 of operation mode F-1/F-2.
pressed.
Operation Changes to the
Description
mode setting value
Turns on control output when The setting value can be
2 Release the [SET] button when "SEt"
flashes on the display.
the detected surfaces is not the configured around 0.
General F-1 This concludes calibration and the sensor
same as the memorized Individual setting values
reference surface. cannot be changed. returns to the detection state.
The current value for the The setting value can be MAX
memorized surface is forcibly
Detection value
configured around 0.
Special F-2 set to 0. (The display is Individual setting values The value is set to the mean value
common for channels 1 and 2.) can be adjusted. Setting between the maximum and minimum
value values detected while the [SET] button is
pressed down.
Use the reference surface (DATUM) detection method in the following situations:
MIN Time
DATUM
DATUM 1spot
LASER
1
OUT SEL
2
SET 1
2 MODE
TIM
BANK CLP
series
5 GV-IM-E
1-point area calibration (operation mode: F-2) Initial reset (initialization) and custom save function
1 Press and hold the [SET] button
for at least three seconds with the Initial reset (initialization)
workpiece that you want to detect Returns all of the settings to the factory defaults.
in place.
3 Press the [Up] or [Down] arrow button to select "rSt ini", and then
Configuring the sensitivity setting for reference press the [MODE] button to initialize.
surface (DATUM) detection method
Custom save (Saving the settings)
Reference surface (DATUM) calibration (operation Saves all of the settings. The saved settings can be loaded at a later time.
mode: F-1, F-2)
This method memorizes the state without a workpiece (reference surface) and
use it to perform comparator output when the state differs from the reference
1 While pressing the [MODE] button, press the [SET] button five times.
surface (when there is a workpiece).
2 Press the [Left] or [Right] arrow button to display "SAv".
1 Press the [SET] button once without a
workpiece in place. 3 Press the [Down] arrow button to display "SAv no".
Reference When "SAv no" is displayed, pressing the [MODE] button returns to the
2 Press and hold the [SET] button for at main screen without saving the settings.
least three seconds without the
workpiece in place.
4 Press the [Up] or [Down] arrow button to select "Sav YES", and then
press the [MODE] button to save the settings.
Note
Performing custom save overwrites the settings from the previous custom
When performing reference surface calibration, the values are set for slightly above save.
and slightly below the reference surface. When the detection value falls within this
range, comparator output is turned off. When it falls outside of this range, comparator
output is turned on.
Custom reset (Loading the settings)
z Operations during F-1 mode Loads the settings saved with custom save.
The setting value can be adjusted by using the [Up] and [Down] arrow buttons,
but the HIGH and LOW setting values cannot be adjusted individually.
1 While pressing the [MODE] button, press the [SET] button five times.
z Operations during F-2 mode
The HIGH and LOW setting values can be adjusted individually by using the [Up]
and [Down] arrow buttons.
2 Press the [Down] arrow button to display "rSt no".
Reference When "rSt no" is displayed, pressing the [MODE] button returns to the
main screen without performing custom reset.
Note • Reference surface calibration cannot be used during the following states.
(Instead, 2-point calibration is performed.)
• The spot reflection indicator (1spot) is flashing on the sensor head or 3 Press the [Up] or [Down] arrow button to select "rSt CSt", and then
sensor amplifier. press the [MODE] button to load the settings.
• The setting is control output 2.
• A mode other than F-1 mode or F-2 mode is being used. Note
Performing custom reset erases the current settings.
• Reference surface calibration can only be set when the operation mode
is F-1 or F-2.
• When performing reference surface calibration, the current value is set to
0.
Bank switching
The bank function allows two patterns of sensitivity settings to be saved in channels 1
Clearing reference surface (DATUM) detection method and 2. (This is useful during operations such as switching the setup.)
When the reference surface (DATUM) detection indicator is lit, press and hold the
[Up] and [Down] arrow buttons for at least three seconds. The reference surface • The bank switching function can only be used when the external input is set to "bnk" in the
(DATUM) detection indicator turns off and the sensor returns to distance OPTIONAL settings.
detection method. • Hold down the [MODE] button during main screen and press the [Up] arrow button to
The value is canceled if a form of calibration other than reference surface switch banks, which allows the settings to be configured for each bank.
calibration. • During the keylock state, the banks are switched with external input.
Note When the external input is off, bank A is used. When the external input is on,
bank B is used.
Other Settings
Zero point positioning DATUM DATUM
workpiece in place. Bank A is in use : Bank indicator is off Bank B is in use : Bank indicator is on
The current value becomes "0" and zero point positioning is complete.
Note When the shift target value is set, performing zero point positioning does not
make the current value "0". Instead, it becomes the set value for the shift
target value.
For more information about setting the shift target value, see page 9 of this
Instruction Manual.
Reference Pressing the [Up] and [Down] arrow buttons simultaneously for at least
three seconds cancels the zero point (shift target value).
GV-IM-E 6
Keylock Function
DATUM
The keylock function prevents accidental operation of the buttons during detection. Delay timer 1: Timer value T1
While using the keylock function, operations other than switching the display for the SET 1
2 MODE Setting range: 2 to 999 (Unit: ms)
main screen are prohibited. When
MODE
or
Note The keylock settings can only be set in the main screen.
is selected DATUM
is selected
SET 2 MODE Setting range: t-2oFF/oFd/ond/
Sht/ondoFd/ondSht
Interference protection function MODE
or
The GV Series can prevent mutual interference that may occur when connecting
DATUM
MODE
Press and hold the [MODE] button for at least three seconds in the main screen or
(during detection) to change the settings.
7 Hysteresis
DATUM
When
Note The screen shown to the right is displayed DATUM
MODE
or
MODE DATUM
Press for about 3 seconds Hysteresis value
SET 1
2 MODE Setting range: Varies depending
1 Response speed
DATUM
on the sensor head
MODE model.
or
Setting range: 1.5/3/10/20/50 SET 1
2 MODE
(Unit: ms)
8 External input
DATUM
MODE
or
SET 1
2 MODE
Setting range: oFF/SFt/bnK/tim
2 Output mode
DATUM
MODE
or
SET 1
Setting range: noo/nCo/noC/nCC 2 MODE
MODE
or
SET 1
2 MODE Setting range: -199 to 999
DATUM
DATUM (-198 to 998)
MODE
or
SET 1
SET 1
MODE 2 MODE
2
10 Distance display
DATUM
or MODE
or
SET 1
2 MODE Setting range: nor/rEv
DATUM
MODE
or
SET 1
MODE 2 MODE
or
11 Eco display
DATUM
MODE
or
3 Operation mode
DATUM
DATUM
SET 1
2 MODE Setting range: F-1/F-2/A-1/A-2 SET 1
MODE
2
MODE
or MODE
or
4 Clamp function
DATUM
DATUM
SET 1
MODE
2
Setting range: ON/OFF SET 1
2 MODE
MODE
or End of optional settings
When
Reference • While configuring basic settings, pressing and holding the [MODE]
is selected
SET 1
2 MODE Setting range: t-1oFF/oFd/ond/ button for at least three seconds on any setting screen saves the
Sht/ondoFd/ondSht settings, ends basic setting, and displays the main screen.
MODE
or • Press the [Left] arrow button to return to the previous setting item.
7 GV-IM-E
1. Response speed setting
Display
The response speed is the time from when the sensor head starts detection until
the value at the detection position is established as a comparator value.
Setting value
Item Setting range Default value
Response
speed
1.5/3/10/20/50 (Unit: ms) 10* Time
ON t1 t1
* "20" for GV-H1000 (L) only. On-delay
OFF
ON
Off-delay t1 t1 t1
OFF
2. Output mode setting ON t1 t1 t1 t1
One-shot
Sets the control output mode for each control output. OFF
Item Description Default value On-delay/ ON t1 t1
Off-delay OFF t2 t2
Control Control On-delay/ ON t1 t1
Settings
output 1 output 2 One-shot OFF
noo N.O. N.O. t2 t2
Output mode noo
nCo N.C. N.O. t1: Timer value T1
noC N.O. N.C. t2: Timer value T2
nCC N.C. N.C.
7. Hysteresis setting
Reference N.O. (normal open) and N.C. (normal close) operate in the following Sets the hysteresis for judgment with control outputs 1 and 2.
manner.
Setting item Description Default value
Output mode During detection
N.O. (normal open) ON Std Run with the default values. {
N.C. (normal close) OFF Usr Set custom values.
The hysteresis setting range and default value are as follows when "Usr" is
3. Operation mode selection selected.
Sets the operation mode. Head model Setting range Default value
Operation mode Description Default value GV-H45 (L) 0, 1 to 100 2
F-1 General Normal detection mode { GV-H130 (L)
GV-H450 (L)
0, 2 to 100
0, 0.5, 1 to 100
4
0.5
F-2 Area detection mode GV-H1000 (L) 0, 1 to 100 5
A-1 Special Edge hold mode
A-2 Surface detection mode
8. External input function setting
Sets the function assigned to the external input (pink line).
4. Clamp function setting
Setting item Description Default value
Set the operations when distance detection cannot be performed (such as when
the detection object does not enter the detection range, or when there is oFF Do not use external input (input off). {
insufficient light intensity).
SFt Used as "External shift input".
Setting item Description Default value bnK Used as "Bank switching input".
Outputs the comparator output with the tim Used as "Timing input".
detection value obtained immediately before
the distance was judged to be not detectable.
The current value display and LED bar Reference The minimum external input time is 20 ms.
on
display are also saved for the immediately
preceding value.
If distance detection can be performed, then z External shift input
the hold is released. When external input is input, the current value is shifted by the value set for shift
When the distance detection cannot be target value.
performed and "---" is displayed, the (For information about the shift target value, see "9. Shift target value setting".)
oFF comparator output operates in the same way
as if a detection object appears at the
{ z Bank switching input
farthest point of the detection range. When keylock is set for the amplifier, the bank switches with input to the external
input.
(For more information about bank switching, see "Bank switching".)
5. (6.) Delay timer setting
Individual delay timers can be set for channels 1 and 2. Note When edge hold mode (A-1 mode) is set, switching banks with the external
Setting item Description Default value input resets the current value to 0.
GV-IM-E 8
9. Setting the shift target value
Troubleshooting
Set this value to shift the current value by another amount.
Item Setting range Default value
Problem Cause and solutions
Shift target
-199 to 999 0 This type of problem sometimes occurs when multiple
value
reflection occurs while using the distance detecting
method. If this problem occurs, use the reference surface
• Press the [Up] and [Down] arrow buttons simultaneously to shift the current detection (DATUM) method and configure the sensitivity
value to the set value with the shift target value. The current value is
setting.
larger than the setting
The shift status is retained even if the power is turned off. If multiple reflection occurs, the spot reflection (1spot)
value, but the output is
indicator turns off.
not reversed.
Reference Press the [Up] and [Down] arrow buttons simultaneously and hold • "Distance detection method (Normal)" (page 4)
them to clear the shifted target value. • "Reference surface detection (DATUM) method
(Application)" (page 5)
• The amplifier does not retain the amount of shift when shifting with external • "Sensor amplifier part names" (page 3)
input. (It is cleared when the power is turned off.) To retain the amount of shift, The external input does Check the settings for the external input.
press the [Up] and [Down] arrow buttons simultaneously and perform shift. not function. • "8. External input function setting" (page 8)
• When performing reference surface calibration while edge hold mode (A-1 The current settings can
mode) is set, the value is always shifted to 0. no longer be Perform initial reset (initialization).
• Shift is only a effective on the selected bank. determined. The user • "Initial reset (initialization) and custom save function"
wants to return the unit (page 6)
to the factory defaults.
10. Distance display setting
Sets whether to use the side close to the sensor head as the positive direction
(normal) or negative direction (reverse).
I/O Circuit Diagram
Setting item Description Default value
nor (Normal)
The display value increases as the target
comes closer to the sensor head. { Output circuit
The display value decreases as the target
rEv (Reverse)
comes closer to the sensor head. GV-21/22 (NPN output)
Brown *
10-30 V DC
{
* GV-21 only
oFF Turns off the eco display.
bAr Turns off the digital display. GV-21P/22P (PNP output)
The digital display (green) flashes in Brown *
10-30 V DC
on sequence. Bar display and channel No.
Sensor main circuit
1
2
through the output wire
• Check that the output wire does not
Overcurrent error touch another wire or a frame. Purple/pink (input)
Data read/write error Perform initialization.
Data has been written in PLC etc.
1
the EEPROM over 1 If you need to write more data, (Short-circuit current 1 mA max.) Blue *
2
0V
million times and can no replace the amplifier unit.
EEPROM error longer be updated. * GV-21 only
There is no workpiece
or background within Set a workpiece or background in GV-21P/22P (PNP output)
the detection distance the distance for detection from the 10-30 V DC
1
2
range, or no light is sensor. Brown *
Sensor main circuit
9 GV-IM-E
Specifications WARRANTIES AND DISCLAIMERS
Sensor head (1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
Item Specifications
models or samples were shown to Buyer, such models or samples were
GV- GV- GV- GV- GV- GV- GV- GV-
H45 H45L H130 H130L H450 H450L H1000 H1000L used merely to illustrate the general type and quality of the Products and
Model not to represent that the Products would necessarily conform to said
Super-Long-
Short-range Mid-range Long-range models or samples. Any Products found to be defective must be shipped to
range
Visible semiconductor laser KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE
Light source
Wavelength: 655 nm for inspection and examination. Upon examination by KEYENCE,
FDA Laser KEYENCE, at its sole option, will refund the purchase price of, or repair or
Class 1 Class 1 Class Class 1 Class Class 1
(CDRH) Class Class Class
replace at no charge any Products found to be defective. This warranty
Part does not apply to any defects resulting from any action of Buyer, including
1040.10 Output 560PW 220PW 560PW 220PW 560PW 220PW 560PW 220PW
but not limited to improper installation, improper interfacing, improper
Laser
IEC Class 2 Class 1 Class 2 Class 1 Class 2 Class 1 Class 2 Class 1 repair, unauthorized modification, misapplication and mishandling, such as
Class
60825-1 exposure to excessive current, heat, coldness, moisture, vibration or
Output 560PW 220PW 560PW 220PW 560PW 220PW 560PW 220PW
Detection distance outdoors air. Components which wear are not warranted.
(Amplifier display 20 to 45 mm 55 to 130 mm 160 to 450 mm 200 to 1000 mm (2) KEYENCE is pleased to offer suggestions on the use of its various
(250 to 0) (750 to 0) (290 to 0) (800 to 0) Products. They are only suggestions, and it is Buyer's responsibility to
value*1)
Amplifier ascertain the fitness of the Products for Buyer’s intended use. KEYENCE
259 to -34 768 to -98 295 to -50 810 to -175
display range will not be responsible for any damages that may result from the use of the
20 mm (Detection Products.
distance 200 to (3) The Products and any samples ("Products/Samples") supplied to Buyer are
Standard
800 mm), not to be used internally in humans, for human transportation, as safety
detection 0.5 mm 1 mm 3 mm
30 mm (Detection
deviation devices or fail-safe systems, unless their written specifications state
distance 800 to
1000 mm) otherwise. Should any Products/Samples be used in such a manner or
Approx. I0.1 mm Approx. I0.3 mm Approx. I0.8 mm Approx. I1.8 mm misused in any way, KEYENCE assumes no responsibility, and additionally
Spot diameter (Detection distance (Detection distance (Detection distance (Detection distance Buyer will indemnify KEYENCE and hold KEYENCE harmless from any
45 mm) 130 mm) 450 mm) 1000 mm) liability or damage whatsoever arising out of any misuse of the Products/
Operation Control output: Red LED Samples.
status Laser radiation emission indicator: Green LED (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
indicators Other: Green LED
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
Enclosure
IP67 EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
rating
Surrounding air WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
-10 to +50°C (No freezing)
Environmental resistance
Metal part: SUS304 OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD
Lens cover Glass PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
Cable PVC BUYER. In some jurisdictions, some of the foregoing warranty disclaimers
Cable length 2m 3m or damage limitations may not apply.
Weight*4 Approx. 120 g Approx. 130 g Approx. 190 g Approx. 210 g
*1 Guideline of the amplifier display value when the distance display for the BUYER'S TRANSFER OBLIGATIONS:
detection distance is set to "nor".
If the Products/Samples purchased by Buyer are to be resold or delivered
*2 For GV-H1000, when the response speed is set to 10 ms or less,
Incandescent lamp: 5,000 lx, Sunlight: 3,000 lx to a third party, Buyer must provide such third party with a copy of this
*3 For GV-H1000L, when the response speed is set to 10 ms or less, document, all specifications, manuals, catalogs, leaflets and written
Incandescent lamp: 2,500 lx, Sunlight: 1,500 lx information provided to Buyer pertaining to the Products/Samples.
*4 Including the connector cable.
E 1101-3
Sensor amplifier
Item Specifications
NPN output GV-21 GV-22
Model
PNP output GV-21P GV-22P
Amplifier type Main unit Expansion unit
Power voltage*1 10-30 VDC, Ripple (P-P): 10% max, Class 2
Normal: 2200 mW max. (at 30 V: 73.3 mA max.)
Power consumption Eco-bar: 1700 mW max. (at 30 V: 56.7 mA max.)
Eco-all: 1600 mW max. (at 30 V: 53.3 mA max.)
Response time 1.5/3/10/20/50 ms
NPN (PNP) open collector x 2ch, 40 V (30 V) DC max.
Control output
Max. 100 mA, residual voltage 1 V max.
Purple line.... Laser emission stop input
Pink line ....... Setting value bank switching input/
Control input
shift input/timing input (selected with
the settings)
Surrounding air
-10 to +55°C (No freezing)
temperature
Environmental Relative
35 to 85% RH (No condensation)
resistance humidity
10 to 55 Hz, 1.5 mm double amplitude in the X, Y,
Vibration
and Z directions, 2 hours respectively
Housing material, front sheet: Polycarbonate
Material Key top: Polyacetal
Cable: PVC
Weight*2 Approx. 110 g
GV-IM-E 10