Keyence GV Laser Sensor IM

This document provides safety and operational information for the GV Series Digital CMOS Laser Sensors. It summarizes that the laser will stop emitting when an emission stop signal is input for 20ms or longer, and will resume emitting up to 20ms after the signal is canceled. It also details the laser warning labels that should be affixed to the sensor depending on the model. Precautions are provided for class 1 and class 2 laser products.

Uploaded by

Felipe rdz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
285 views10 pages

Keyence GV Laser Sensor IM

This document provides safety and operational information for the GV Series Digital CMOS Laser Sensors. It summarizes that the laser will stop emitting when an emission stop signal is input for 20ms or longer, and will resume emitting up to 20ms after the signal is canceled. It also details the laser warning labels that should be affixed to the sensor depending on the model. Precautions are provided for class 1 and class 2 laser products.

Uploaded by

Felipe rdz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

96M11664 „ Laser emission stop input

The laser emission stops when an emission stop (purple line) signal is input (for
20 ms or longer). The emission stops while the signal is input. The laser beam is
emitted a maximum of 20 ms after the signal input is canceled. The control
output functions according to the detection value even while laser emission
stop is input.
Digital CMOS Laser Sensor

GV Series
„ Laser warning labels
The following diagrams show the type and position of laser warning labels
according to the GV Series.
GV-H45(L)/GV-H130(L) GV-H450(L)/GV-H1000(L)
Instruction Manual Aperture label
Aperture label Aperture label
Read this manual before using the software in order to achieve maximum
performance. Aperture label
Keep this manual in a safe place after reading it so that it can be used at any time.

Note The displayed values indicate guidelines for distances and should not
be used in the actual applications for measurement.

Laser
Safety Precautions transmitter Laser
transmitter

• The GV Series is intended for the detection of target objects.


Do not apply the product to safety circuits for human protection.
FDA (CDRH) FDA (CDRH)
WARNING • This product is not of explosion-proof construction. Do not use it warning label (Class )* warning label (Class )*
in a location where any flammable gases, liquid, or powder exist. * Not included with GV-H45L/H130L/H450L/H1000L.

z Aperture label

Safety Precautions on Laser Products


z FDA (CDRH) warning label (CLASS )
• This product employs a semiconductor laser for its light source.
• Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation
exposure.
• Follow the instructions mentioned in this manual. Otherwise, injury
to the human body (eyes and skin) may result.
• Do not disassemble this product. Laser emission from this product
is not automatically stopped when it is disassembled. The FDA (CDRH) warning labels are only affixed to Class laser products.
Precautions on class /2 laser products
• Do not stare into the beam. z IEC warning/explanatory label (CLASS 2)
• Do not direct the beam at other people or into areas
where other people unconnected with the laser work
WARNING might be present.
• Be careful of the path of the laser beam.
If there is a danger that the operator may be exposed
to the laser beam reflected by specular or diffuse
The IEC warning/explanatory labels are only included with Class 2 laser
reflection, block the beam by installing an enclosure products.
with the appropriate reflectance.
When using this product in the countries and/or regions other than U.S., use the
• Install the products so that the path of the laser beam IEC warning/explanatory label in the package of this product.
is not as the same height as that of human eye.
In this case, it can be affixed on the FDA (CDRH) warning label, which has
Precaution on class 1 laser products already been affixed to this product.
• Do not stare into the beam.

Checking the Package Contents


Item Description Check if the parts and equipment listed below are included in the package of the
GV-H45, GV-H130, GV-H45L, GV-H130L, model you purchased before using the unit.
Model
GV-H450, GV-H1000 GV-H450L, GV-H1000L
Wavelength 655nm „ Sensor amplifier
FDA (CDRH) Laser Class Class Laser Product Class 1 Laser Product* GV-21/GV-21P (main unit) GV-22/GV-22P (expansion unit)
Part 1040.10 Output 560PW 220PW
Laser Class Class 2 Laser Product Class 1 Laser Product
IEC 60825-1
LASER
DATU LASER
M DATU
1 M

Output 560PW 220PW


OUT 1spot 1
2 OUT 1spot
2
SE
T SE
1 T
2 1

*The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in


2

BA
NK BA
SEL NK
TIM SEL

accordance with the requirements of Laser Notice No.50. CLP

serie
MOD
E
TIM
CLP
MOD
E
s serie
s

Safety measures for the laser Amplifier x1 Amplifier x1


Instruction manual x1

„ Laser radiation emission indicator „ Sensor head


The laser radiation emission indicator lights up after turning on the power and GV-H45(L)/H130(L) GV-H450(L)/H1000(L)
while the laser beam is being emitted.
Sensor amplifier Sensor head

DATUM 1spot
LASER

1
OUT SEL
2

SET 1
2 MODE
TIM
BANK CLP
series

Sensor head x1 Sensor head x1


LASER
Insulating sheet x1 Insulating sheet X1
1
Mounting bracket x1 Mounting bracket x1
OUT
2 Laser radiation emission indicator Board nut x1 Board nut x1
M3 x L30 screw x2 M4 x L35 screw x2
Laser warning sticker* x1 Laser warning sticker* x1
* This is not included with GV-H45L/H130L/H450L/H1000L.

We have thoroughly inspected the package contents before shipment.


However, in the event of defective, broken or missing items, please contact your
nearest KEYENCE office.

1 GV-IM-E
Mounting and Wiring the Sensor Amplifier Connecting and Mounting the Sensor
Head
Mounting the sensor amplifier
Sensor head part names
„ Mounting the GV-21/GV-21P (main unit)
1 Align the claw at the bottom of the (3)
Laser receiver Mounting area
main body with the DIN rail. While
pushing the main body in the LASER
direction of the arrow 1, slant it in the (Laser radiation
(2) emission indicator)
direction of the arrow 2.
OUT
(1)
(Control output
2 To dismount the sensor, raise the indicator)
main body in the direction of the
1spot
arrow 3 while pushing the main body (Spot reflection
in the direction of the arrow 1. indicator)
When using the amplifier mounting bracket
Mounting area
(OP-76877) (sold separately), mount it as
shown in the diagram to the right. Laser Connector

Connecting the sensor head


Amplifier mounting bracket
1 Unlock the sensor head
Connector
„ Mounting the GV-22/GV-22P (expansion unit) connector and insert it into
back of the amplifier.
Several expansion units can be used in connection with the main unit.
Up to three expansion units can be connected to one main unit. Unlocked

• When connecting multiple amplifiers (expansion units), first 2 Turn the round part of the
check to make sure that the power is turned off to all of the connector clockwise until a
main and expansion units. Connecting the units with the clicking sound is heard to lock
power turned on may cause damage to the units. it.
• Push the amplifiers (expansion units) as far as possible into Locked
CAUTION the main unit. If they are connected at a slant or not inserted
securely, the units may be damaged.
• Only GV Series amplifier can be connected (DL Series cannot
be connected). Connecting other amplifiers may cause
damage to the units.
Note When shortening the sensor head cable, follow the instructions given in
the "Sensor Head Connector Assembly Manual" included with the sensor
Note Expansion units with different output types (such as a PNP output main head.
unit to an NPN output expansion unit) cannot be connected together.

1 Remove the expansion Mounting the sensor head


Expansion
protective cover from the protective
GV-21/GV-21P (main unit) cover Use the dedicated mounting bracket to mount the sensor head.
When not using the dedicated mounting bracket, the included insulating sheet must be
GV-21/ inserted between the mounting surface and the sensor head as shown in the diagram.
GV-21P (When using the dedicated mounting bracket, the insulating sheet is not necessary.)

Insulating sheet
2 Install the amplifiers (expansion units) on the DIN rail. Sensor head
For more information about mounting, see "Mounting the GV-21/GV-21P (main
unit)".

3 Push the expansion unit into Main


the main unit connector until unit
Expansion Hexagon socket bolt
a clicking sound can be unit (Accessory)
heard.
z Mounting when detecting z Mounting when detecting
targets close to a wall targets in a hole
Connector

4 Install the end units End


unit
(OP-26751: 2 units in a set)
(sold separately) on either End
unit
side of the amplifiers (main or
expansion units). Secure the
end units in place with screws
on top (2 on each end unit). Receives little effect Variations in the detection The target cannot be detected
from stray laser light. value with effects from when the transmitter or receiver
stray laser light. are blocked.
The end units are mounted in the same way as the amplifiers.
z When detecting uneven workpieces

Amplifier wiring
• Stable detection • Incorrect values
The following information shows the I/O cable. even on uneven can be detected
For more information about the I/O circuit, see page 9 of this Instruction Manual. areas. on the uneven
areas.
Brown*1 *1 GV-22/GV-22P (expansion unit) do not
Blue*1 10-30 V DC have brown or blue lines. Power is supplied
to the expansion units through GV-21/GV-
Black 21P (main unit).
Control output 1
White *2 The external input switches as shown
Control output 2
Pink*2 below depending on the amplifier
External input OPTIONAL settings.
Purple
Laser emission • oFF ......... Input off
stop input • SFt .......... External shift
• bnK ......... Bank switching
• tim ........... Timing input

GV-IM-E 2
Example When using sensor head GV-H130
Sensor Amplifier
Sensor amplifier part names
Spot reflection (1spot) indicator*2 Distance
Reference surface (DATUM) detection (green)
indicator*1 (red) Current value display 0mm
Current value
Setting value display (green) (red) Arrow
buttons 55mm 750 Minimum detection distance
DATUM 1spot
Laser radiation emission LASER
indicator (green) 1 130mm 0 Maximum detection distance
Output status indicator OUT SEL
2
(red)
SET 1
2 TIM
MODE For example, when using the defaults with the setting value (green) at 500, the
[SET] button comparator output turns on when the current value is 500 or greater and turns off
BANK CLP
series when it is less than 500.
If multiple reflection (when multiple peaks of received light intensity occurs due to
Channel No. indicator (green) CLP function indicator*3 [MODE] button diffuse reflection) occurs during F-1, F-2, or A-1 modes, the value immediately before
(red) the current value is held.
Bank input indicator (green) LED bar Timing input indicator*4 (red)

z Setting value
*1 The reference surface (DATUM) detection indicator lights up when performing The following table shows the default setting values for each channel.
reference surface detection. For more information, see "Reference surface
detection (DATUM) method (Application)" on page 5 of this Instruction Manual. Operation Default value
Item
*2 The spot reflection indicator lights up during normal detection and turns off during mode GV-H45 (L) GV-H130 (L) GV-H450 (L) GV-H1000 (L)
multiple reflection (when multiple peaks of received light intensity occurs due to Control output 1 (black)
diffuse reflection), insufficient light intensity, and when the target is out of the 150 500 200 500
F-1, A-1, (Channel 1 lit)
detection range. A-2 Control output 2 (white)
*3 For more information about the CLP (clamp) function indicator, see "4. Clamp 125 400 150 400
(Channel 2 lit)
function setting" on page 8 of this Instruction Manual.
Control output 1 (black) HIGH
*4 For more information about the timing input indicator, see "8. External input 150 500 200 500
(Channel 1 lit)
setting" on page 8 of this Instruction Manual.
Control output 1 (black) LOW
100 300 100 300
(Channel 2 lit)
F-2
Control output 2 (white) HIGH
Main screen (Channel 1 flashing)
125 400 150 400
Control output 2 (white) LOW
75 200 50 200
The main screen can be switched between "Current/setting value display" and "Peak/ (Channel 2 flashing)
bottom value display". The main screen can be switched even during keylock.
z Peak/bottom values
DATUM
Peak value: Resets when the detection value exceeds the setting value
and holds the maximum value (peak value) until the detection
value falls below the setting value again.
SET 1

Setting value (green)


2 MODE
Bottom value: Resets when the detection value falls below the setting value
and holds the minimum value (bottom value) until the
Current value (red) detection value exceeds the setting value again.
Alternate
DATUM DATUM
Reference The held peak and bottom values can be cleared by pressing and
hold the [Up] arrow button.

SET 1 SET 1
2 MODE 2 MODE

or
Channel No. indicators Peak value (green) Bottom value (red)

Setting value/current value display Peak value/bottom value display


Pressing the [MODE] button switches Pressing the [UP] arrow button
the channels (channel No. indicators). resets the peak and bottom values.
Pressing the [Up] and [Down] arrow buttons simultaneously on the main screen
forces the current value (red) to 0*.
* With the default settings. For details, see "9. Shift target value setting" on page 9 of
this Instruction Manual.

Note When the channel No. 1 indicator is lit, the control output 1 (black line)
setting value is displayed. When the channel No. 2 indicator is lit, the control
output 2 (white line) setting value is displayed.
Operations are different in F-2 mode. (See page 5 of this Instruction
Manual.)

z Current value and display resolution


In the default state, the current value shows 0 when the workpiece is located at
the maximum detection distance. Bringing the workpiece closer to the sensor
head gradually increases the value and displays it up to the minimum detection
distance.
Current value
Item
GV-H45 (L) GV-H130 (L) GV-H450 (L) GV-H1000 (L)
Detecting range (mm) 20.0 to 45.0 55.0 to 130.0 160 to 450 200 to 1000
Digital display (initial) 250 to 0 750 to 0 290 to 0 800 to 0
Display resolution 1 2 1 5

Note The displayed values indicate guidelines for distances and should not be
used in the actual applications for measurement.

3 GV-IM-E
Using Basic Operations
Configuring the Sensitivity Setting and
Operation Mode
Configure the sensitivity setting in F-1 mode (with the default settings).

2-point calibration Detection method


The setting is automatically calculated as the mean value detected from two
points: with the workpiece and without the workpiece. The GV Series has two type of detection methods: "Distance detection method" and
"Reference surface (DATUM) detection method".
1 Press the [SET] button once The reference surface (DATUM) detection method can only be used when
performing reference surface calibration.
without a workpiece in place.
The current value without the Note Control output 2 is fixed to distance detection method for all operation modes.
workpiece is read.

„ Distance detection method (Normal)


Detects the distance between the detection target and the sensor head, and
then performs control output. The following table shows each operation mode
and the auto calibration that can be used.
2 Place a workpiece in the
Usable
detection position, and quickly Operation mode Description
press the [SET] button once auto calibration
again. Normal detection mode 2-point calibration
The most general mode. Full auto calibration
This concludes 2-point calibration General F-1
ON/OFF judgment is performed Maximum sensitivity
and the sensor returns to the
based on one setting value. setting
detection state.
Area detection mode
On/OFF judgment is performed 2-point area calibration
F-2
on an area based on two 1-point area calibration
settings.
Edge hold mode 2-point calibration
Detects the change in distance Full auto calibration
Reference If there is very little difference between the values obtained in A-1
Special (derivation) to the target and Maximum sensitivity
Step 1 and Step 2, then "---" flashes in the setting value display
holds the display. setting
area after calibration is complete. The setting value is still
updated. Surface detection mode
2-point calibration
When multiple beams of light are
Full auto calibration
Fine-tune setting value A-2 reflected from the detection
Maximum sensitivity
target, the closest reflected light
Use the [Up] and [Down] arrow buttons to fine-tune the setting value. setting
is judged as the detection value.
Increases
DATUM
the setting Item Setting range
value Setting z Area detection mode (F-2 mode)
SET 1
MODE Decreases value
2
-199 to 999 Operation image
the setting fine-
value tuning

Reference surface (DATUM) calibration


Use DATUM calibration when comparator output cannot be performed
OFF
correctly during 2-point calibration (due to problems such as chattering from
HIGH setting value
the surface of the workpiece).
ON
LOW setting value
3 Press the [SET] button once without a workpiece in place OFF
(reference surface).

4 Using the same conditions, Only this will turn ON.

When using the F-2 mode, the channel No. indicator switches in the following order
each time the [MODE] button is pressed.

MODE
Press once.

1
MODE
1
MODE MODE
1
Press once. Press once. 1 Press once.
2 2 2
2
Control output 1 Control output 1 Control output 2 Control output 2
(black) HIGH setting (black) LOW setting (white) HIGH setting (white) LOW setting
value value value value
• Channel No. 1 • Channel No. 2 • Channel No. 1 • Channel No. 2
indicator lights up indicator lights up indicator flashes indicator flashes

GV-IM-E 4
z Edge hold mode (A-1 mode) Configuring the sensitivity setting for distance
This operation mode is suitable for detecting workpieces on a conveyer or
detecting workpieces with waving backgrounds. It ignores slow distance detection method
changes and only detects workpieces (sudden changes in height).

When height differences greater than the setting value are detected (low areas „ 2-point calibration (operation modes: F-1, A-1, A-2)
become high), the value at the detected time are held and displayed, and control
output starts. 1 Press the [SET] button once without a
If the difference is small and does not exceed the setting value, the display stays as 0. workpiece in place.
When height differences greater than the setting value are detected (high areas The current value without the workpiece is
become low), detection value becomes 0 and control output is stopped. read.

2 Place a workpiece in the detection


position, and quickly press the [SET]
Detection
button once again.
value The setting value is calculated as the mean
value between the value obtained in step 1
and the value obtained in step 2.
0
This concludes 2-point calibration and the
Control ON sensor returns to the detection state.
output OFF

Note • When edge hold mode (A-1 mode) is selected, edge hold mode only
operates on channel 1. Channel 2 operates under distance Reference If there is very little difference between the values obtained in Step 1
measurement mode (F-1 mode). and Step 2, then "---" flashes in the setting value display area after
• If the edges are gentle (such as spherical or tilted workpieces), this calibration is complete. The setting value is still updated.
mode may not be able to detect workpieces or may output the value
incorrectly.
• Send the workpiece past the sensor head so that the area for „ Maximum sensitivity setting (operation modes: F-1, A-1, A-2)
detecting height differences is parallel to the sensor head. See
"When detecting uneven workpieces" (page 3). 1 Press and hold the [SET] button for at least three seconds without a
workpiece in place.
Reference • When a detection value is being held, press and hold the [Up] and
[Down] arrow buttons at the same time to set the current value to 0
(regardless of the shift target value) and to turn off output. The 2 Release the [SET] button when "SEt" flashes on the display.
current value for channel 2 changes to 0 as well. This concludes maximum sensitivity calibration and the sensor returns to the
• If the external input function is set to "SFt" and the external input detection state.
(pink line) is turned on, the control output turns off and the current
value becomes 0. (When channel 2 is selected, the current value
becomes 0 as well. Turning the laser emission stop input on and off „ Full auto calibration (operation modes: F-1, A-1, A-2)
performs a similar action, but it only changes the current value of
the channel to 0.) This method performs calibration while the target is moving.

„ Reference surface detection (DATUM) method (Application) 1 Press and hold the [SET] button for at
least three seconds while the target
This method memorizes the background (reference surface) and uses it to
workpiece is passing through the
perform comparator output when there is a workpiece (when the state differs
from the reference surface).
detection area for the sensor.
The sensitivity is set according to the
The reference surface detection (reference surface calibration) can only be used
detection value while the [SET] button is
on Channel 1 of operation mode F-1/F-2.
pressed.
Operation Changes to the
Description
mode setting value
Turns on control output when The setting value can be
2 Release the [SET] button when "SEt"
flashes on the display.
the detected surfaces is not the configured around 0.
General F-1 This concludes calibration and the sensor
same as the memorized Individual setting values
reference surface. cannot be changed. returns to the detection state.
The current value for the The setting value can be MAX
memorized surface is forcibly
Detection value

configured around 0.
Special F-2 set to 0. (The display is Individual setting values The value is set to the mean value
common for channels 1 and 2.) can be adjusted. Setting between the maximum and minimum
value values detected while the [SET] button is
pressed down.
Use the reference surface (DATUM) detection method in the following situations:
MIN Time

„ 2-point area calibration (operation mode: F-2)


1 Place a workpiece on the upper limit
that you want the sensor to detect,
and press the [SET] button once.
That upper limit becomes the HIGH setting
value.
Influence of diffuse Split spot Insufficient light
reflection
(Multiple reflection)
(Multiple reflection) intensity
2 Place a workpiece on the lower limit Upper limit
that you want the sensor to detect,
During reference screen (DATUM) detection, the background is memorizes as
and press the [SET] button once.
That lower limit becomes the LOW setting Lower limit
references. During the unstable situations noted above, a workpiece is judged as
present when the detected surface is different from the background. value.
This makes stable detection possible even when using workpieces with unstable
shapes.
Reference If there is very little difference between the values obtained in Step 1
The reference surface (DATUM) detection indicator lights up when using reference and Step 2, then "---" flashes in the setting value display area after
surface detection after performing reference surface (DATUM) calibration. calibration is complete. The setting value is still updated.

DATUM

DATUM 1spot
LASER

1
OUT SEL
2

SET 1
2 MODE
TIM
BANK CLP
series

5 GV-IM-E
„ 1-point area calibration (operation mode: F-2) Initial reset (initialization) and custom save function
1 Press and hold the [SET] button
for at least three seconds with the „ Initial reset (initialization)
workpiece that you want to detect Returns all of the settings to the factory defaults.
in place.

2 Release the [SET] button when


Set the values for the
upper and lower
1 While pressing the [MODE] button, press the [SET] button five times.
"SEt" flashes on the display. distance.
This concludes 1-point area calibration 2 Press the [Down] arrow button to display "rSt no".
HIGH setting value
and the sensor returns to the detection
state. Reference When "rSt no" is displayed, pressing the [MODE] button returns to the
LOW setting value
main screen without initializing.

3 Press the [Up] or [Down] arrow button to select "rSt ini", and then
Configuring the sensitivity setting for reference press the [MODE] button to initialize.
surface (DATUM) detection method
„ Custom save (Saving the settings)
„ Reference surface (DATUM) calibration (operation Saves all of the settings. The saved settings can be loaded at a later time.
mode: F-1, F-2)
This method memorizes the state without a workpiece (reference surface) and
use it to perform comparator output when the state differs from the reference
1 While pressing the [MODE] button, press the [SET] button five times.
surface (when there is a workpiece).
2 Press the [Left] or [Right] arrow button to display "SAv".
1 Press the [SET] button once without a
workpiece in place. 3 Press the [Down] arrow button to display "SAv no".

Reference When "SAv no" is displayed, pressing the [MODE] button returns to the
2 Press and hold the [SET] button for at main screen without saving the settings.
least three seconds without the
workpiece in place.
4 Press the [Up] or [Down] arrow button to select "Sav YES", and then
press the [MODE] button to save the settings.

Note
Performing custom save overwrites the settings from the previous custom
When performing reference surface calibration, the values are set for slightly above save.
and slightly below the reference surface. When the detection value falls within this
range, comparator output is turned off. When it falls outside of this range, comparator
output is turned on.
„ Custom reset (Loading the settings)
z Operations during F-1 mode Loads the settings saved with custom save.
The setting value can be adjusted by using the [Up] and [Down] arrow buttons,
but the HIGH and LOW setting values cannot be adjusted individually.
1 While pressing the [MODE] button, press the [SET] button five times.
z Operations during F-2 mode
The HIGH and LOW setting values can be adjusted individually by using the [Up]
and [Down] arrow buttons.
2 Press the [Down] arrow button to display "rSt no".

Reference When "rSt no" is displayed, pressing the [MODE] button returns to the
main screen without performing custom reset.
Note • Reference surface calibration cannot be used during the following states.
(Instead, 2-point calibration is performed.)
• The spot reflection indicator (1spot) is flashing on the sensor head or 3 Press the [Up] or [Down] arrow button to select "rSt CSt", and then
sensor amplifier. press the [MODE] button to load the settings.
• The setting is control output 2.
• A mode other than F-1 mode or F-2 mode is being used. Note
Performing custom reset erases the current settings.
• Reference surface calibration can only be set when the operation mode
is F-1 or F-2.
• When performing reference surface calibration, the current value is set to
0.
Bank switching
The bank function allows two patterns of sensitivity settings to be saved in channels 1
„ Clearing reference surface (DATUM) detection method and 2. (This is useful during operations such as switching the setup.)
When the reference surface (DATUM) detection indicator is lit, press and hold the
[Up] and [Down] arrow buttons for at least three seconds. The reference surface • The bank switching function can only be used when the external input is set to "bnk" in the
(DATUM) detection indicator turns off and the sensor returns to distance OPTIONAL settings.
detection method. • Hold down the [MODE] button during main screen and press the [Up] arrow button to
The value is canceled if a form of calibration other than reference surface switch banks, which allows the settings to be configured for each bank.
calibration. • During the keylock state, the banks are switched with external input.

Note When the external input is off, bank A is used. When the external input is on,
bank B is used.
Other Settings
Zero point positioning DATUM DATUM

Sets the current value to zero (shift target value).


SET 1
2 MODE SET 1
2 MODE
MODE
1 Press the [Up] and [Down] arrow buttons simultaneously without a
BANK BANK

workpiece in place. Bank A is in use : Bank indicator is off Bank B is in use : Bank indicator is on
The current value becomes "0" and zero point positioning is complete.

Note When the shift target value is set, performing zero point positioning does not
make the current value "0". Instead, it becomes the set value for the shift
target value.
For more information about setting the shift target value, see page 9 of this
Instruction Manual.

Reference Pressing the [Up] and [Down] arrow buttons simultaneously for at least
three seconds cancels the zero point (shift target value).

GV-IM-E 6
Keylock Function
DATUM

The keylock function prevents accidental operation of the buttons during detection. Delay timer 1: Timer value T1
While using the keylock function, operations other than switching the display for the SET 1
2 MODE Setting range: 2 to 999 (Unit: ms)
main screen are prohibited. When
MODE
or
Note The keylock settings can only be set in the main screen.
is selected DATUM

Delay timer 1: Timer value T2


Setting/releasing keylock
While pressing the [MODE] button in the main
SET 1
2 MODE Setting range: 2 to 999 (Unit: ms)
DATUM

screen, press and hold the [UP] or [Down]


button for at least three seconds. MODE
SET
or
This sets (or releases) keylock and returns the 1
2 MODE

sensor to the main screen.


6 Delay timer 2 (Control output 2)
DATUM

During keylock When


1

is selected
SET 2 MODE Setting range: t-2oFF/oFd/ond/
Sht/ondoFd/ondSht
Interference protection function MODE
or
The GV Series can prevent mutual interference that may occur when connecting
DATUM

several expansion units. Delay timer 2: Timer value T1


The interference protection function only works when the following conditions are
met. SET 1
2 MODE Setting range: 2 to 999 (Unit: ms)
When
• Interference protection functions on up to two adjacent units. MODE
• The main unit and expansion units use the same response speed. or
• The response speed is set to 1.5, 3, or 10.
is selected DATUM

Delay timer 2: Timer value T2


SET 1
MODE Setting range: 2 to 999 (Unit: ms)
Setting Each Type of Function
2

MODE
Press and hold the [MODE] button for at least three seconds in the main screen or
(during detection) to change the settings.

7 Hysteresis
DATUM

When
Note The screen shown to the right is displayed DATUM

during keylock and basic settings cannot be is selected SET 1


2 MODE Setting range: Std/USr
input. SET 1
2 MODE

MODE
or
MODE DATUM
Press for about 3 seconds Hysteresis value
SET 1
2 MODE Setting range: Varies depending

1 Response speed
DATUM
on the sensor head
MODE model.
or
Setting range: 1.5/3/10/20/50 SET 1
2 MODE

(Unit: ms)
8 External input
DATUM

MODE
or
SET 1
2 MODE
Setting range: oFF/SFt/bnK/tim

2 Output mode
DATUM

MODE
or
SET 1
Setting range: noo/nCo/noC/nCC 2 MODE

9 Shift target value


DATUM

MODE
or
SET 1
2 MODE Setting range: -199 to 999
DATUM
DATUM (-198 to 998)
MODE
or
SET 1
SET 1
MODE 2 MODE
2

10 Distance display
DATUM

or MODE
or
SET 1
2 MODE Setting range: nor/rEv
DATUM

MODE
or
SET 1
MODE 2 MODE

or
11 Eco display
DATUM

End of basic settings


SET 1
2 MODE Setting range: oFF/bAr/on

MODE
or

3 Operation mode
DATUM
DATUM

SET 1
2 MODE Setting range: F-1/F-2/A-1/A-2 SET 1
MODE
2

MODE
or MODE
or

4 Clamp function
DATUM
DATUM

SET 1
MODE
2
Setting range: ON/OFF SET 1
2 MODE

MODE
or End of optional settings

5 Delay timer 1 (Control output 1)


DATUM

When
Reference • While configuring basic settings, pressing and holding the [MODE]
is selected
SET 1
2 MODE Setting range: t-1oFF/oFd/ond/ button for at least three seconds on any setting screen saves the
Sht/ondoFd/ondSht settings, ends basic setting, and displays the main screen.
MODE
or • Press the [Left] arrow button to return to the previous setting item.

7 GV-IM-E
„ 1. Response speed setting
Display
The response speed is the time from when the sensor head starts detection until
the value at the detection position is established as a comparator value.
Setting value
Item Setting range Default value
Response
speed
1.5/3/10/20/50 (Unit: ms) 10* Time
ON t1 t1
* "20" for GV-H1000 (L) only. On-delay
OFF
ON
Off-delay t1 t1 t1
OFF
„ 2. Output mode setting ON t1 t1 t1 t1
One-shot
Sets the control output mode for each control output. OFF
Item Description Default value On-delay/ ON t1 t1
Off-delay OFF t2 t2
Control Control On-delay/ ON t1 t1
Settings
output 1 output 2 One-shot OFF
noo N.O. N.O. t2 t2
Output mode noo
nCo N.C. N.O. t1: Timer value T1
noC N.O. N.C. t2: Timer value T2
nCC N.C. N.C.
„ 7. Hysteresis setting
Reference N.O. (normal open) and N.C. (normal close) operate in the following Sets the hysteresis for judgment with control outputs 1 and 2.
manner.
Setting item Description Default value
Output mode During detection
N.O. (normal open) ON Std Run with the default values. {
N.C. (normal close) OFF Usr Set custom values.

The hysteresis setting range and default value are as follows when "Usr" is
„ 3. Operation mode selection selected.

Sets the operation mode. Head model Setting range Default value
Operation mode Description Default value GV-H45 (L) 0, 1 to 100 2
F-1 General Normal detection mode { GV-H130 (L)
GV-H450 (L)
0, 2 to 100
0, 0.5, 1 to 100
4
0.5
F-2 Area detection mode GV-H1000 (L) 0, 1 to 100 5
A-1 Special Edge hold mode
A-2 Surface detection mode
„ 8. External input function setting
Sets the function assigned to the external input (pink line).
„ 4. Clamp function setting
Setting item Description Default value
Set the operations when distance detection cannot be performed (such as when
the detection object does not enter the detection range, or when there is oFF Do not use external input (input off). {
insufficient light intensity).
SFt Used as "External shift input".
Setting item Description Default value bnK Used as "Bank switching input".
Outputs the comparator output with the tim Used as "Timing input".
detection value obtained immediately before
the distance was judged to be not detectable.
The current value display and LED bar Reference The minimum external input time is 20 ms.
on
display are also saved for the immediately
preceding value.
If distance detection can be performed, then z External shift input
the hold is released. When external input is input, the current value is shifted by the value set for shift
When the distance detection cannot be target value.
performed and "---" is displayed, the (For information about the shift target value, see "9. Shift target value setting".)
oFF comparator output operates in the same way
as if a detection object appears at the
{ z Bank switching input
farthest point of the detection range. When keylock is set for the amplifier, the bank switches with input to the external
input.
(For more information about bank switching, see "Bank switching".)
„ 5. (6.) Delay timer setting
Individual delay timers can be set for channels 1 and 2. Note When edge hold mode (A-1 mode) is set, switching banks with the external
Setting item Description Default value input resets the current value to 0.

oFF Delay timer is not used { z Timing input


ond On-delay Comparator output is only output over control output 1 when external input is on.
oFd Off-delay The timing input indicator on the sensor amplifier lights up.
Sht One-shot
Reference Control output 2 continues to output comparator output, regardless of
ondoFd On-delay/off-delay
whether timing input is on or off.
ondSht On-delay/one-shot

GV-IM-E 8
„ 9. Setting the shift target value
Troubleshooting
Set this value to shift the current value by another amount.
Item Setting range Default value
Problem Cause and solutions
Shift target
-199 to 999 0 This type of problem sometimes occurs when multiple
value
reflection occurs while using the distance detecting
method. If this problem occurs, use the reference surface
• Press the [Up] and [Down] arrow buttons simultaneously to shift the current detection (DATUM) method and configure the sensitivity
value to the set value with the shift target value. The current value is
setting.
larger than the setting
The shift status is retained even if the power is turned off. If multiple reflection occurs, the spot reflection (1spot)
value, but the output is
indicator turns off.
not reversed.
Reference Press the [Up] and [Down] arrow buttons simultaneously and hold • "Distance detection method (Normal)" (page 4)
them to clear the shifted target value. • "Reference surface detection (DATUM) method
(Application)" (page 5)
• The amplifier does not retain the amount of shift when shifting with external • "Sensor amplifier part names" (page 3)
input. (It is cleared when the power is turned off.) To retain the amount of shift, The external input does Check the settings for the external input.
press the [Up] and [Down] arrow buttons simultaneously and perform shift. not function. • "8. External input function setting" (page 8)
• When performing reference surface calibration while edge hold mode (A-1 The current settings can
mode) is set, the value is always shifted to 0. no longer be Perform initial reset (initialization).
• Shift is only a effective on the selected bank. determined. The user • "Initial reset (initialization) and custom save function"
wants to return the unit (page 6)
to the factory defaults.
„ 10. Distance display setting
Sets whether to use the side close to the sensor head as the positive direction
(normal) or negative direction (reverse).
I/O Circuit Diagram
Setting item Description Default value
nor (Normal)
The display value increases as the target
comes closer to the sensor head. { Output circuit
The display value decreases as the target
rEv (Reverse)
comes closer to the sensor head. GV-21/22 (NPN output)
Brown *
10-30 V DC

Sensor main circuit


„ 11. Eco display setting

Overcurrent protection circuit


Black/white (control output 1/2)
Set this parameter to reduce the consumption current or to stop displaying Load 5-40 V DC
specific values. When running in power saving (eco) mode, pressing any button
returns the sensor to normal operations.
The main screen switches to eco mode if no operations take place for 30
seconds. Blue *
0V
Setting item Description Default value

{
* GV-21 only
oFF Turns off the eco display.
bAr Turns off the digital display. GV-21P/22P (PNP output)
The digital display (green) flashes in Brown *
10-30 V DC
on sequence. Bar display and channel No.
Sensor main circuit

Overcurrent protection circuit

indicators are turned off.

Black/white (control output 1/2)


Load
Error Displays and Corrective Actions Blue *

Error indication Error contents Remedy * GV-21P only


• Check that the sensor head is Power is supplied to the expansion unit GV-22(P) from the expansion connector on
connected. the back of the main unit GV-21(P). The power wires (brown and blue) of the main
Sensor head is not
• Check that the head cable is not unit and those of the expansion unit are common inside through the connector.
connected.
broken.
1 Head cable is broken.
2
• Check the connection of the
Sensor head is
Head error head cable to the connector.
damaged
• After checking these points, turn Input circuit
on the power again.
• Check the load and reduce the GV-21/22 (NPN output)
current to be within the rated
Overcurrent is flowing
range. 5 V DC
Sensor main circuit

1
2
through the output wire
• Check that the output wire does not
Overcurrent error touch another wire or a frame. Purple/pink (input)
Data read/write error Perform initialization.
Data has been written in PLC etc.
1
the EEPROM over 1 If you need to write more data, (Short-circuit current 1 mA max.) Blue *
2
0V
million times and can no replace the amplifier unit.
EEPROM error longer be updated. * GV-21 only
There is no workpiece
or background within Set a workpiece or background in GV-21P/22P (PNP output)
the detection distance the distance for detection from the 10-30 V DC
1
2
range, or no light is sensor. Brown *
Sensor main circuit

entering the receiver.


PLC etc.
Reading exceeds the Set a workpiece or background in
detection distance the distance for detection from the
1
2
range. sensor. Purple/pink (input)

Light intensity is Tilt the sensor head so that specular


1
2
saturated. reflection does not enter the sensor. * GV-21P only

Purple line . . . . . . . Laser emission stop input


Pink line . . . . . . . . . External input function*

* The external input function can be set to one of the following.


• Not used
• Shift input
• Bank switching input
• Timing input

9 GV-IM-E
Specifications WARRANTIES AND DISCLAIMERS
„ Sensor head (1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
Item Specifications
models or samples were shown to Buyer, such models or samples were
GV- GV- GV- GV- GV- GV- GV- GV-
H45 H45L H130 H130L H450 H450L H1000 H1000L used merely to illustrate the general type and quality of the Products and
Model not to represent that the Products would necessarily conform to said
Super-Long-
Short-range Mid-range Long-range models or samples. Any Products found to be defective must be shipped to
range
Visible semiconductor laser KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE
Light source
Wavelength: 655 nm for inspection and examination. Upon examination by KEYENCE,
FDA Laser KEYENCE, at its sole option, will refund the purchase price of, or repair or
Class 1 Class 1 Class Class 1 Class Class 1
(CDRH) Class Class Class
replace at no charge any Products found to be defective. This warranty
Part does not apply to any defects resulting from any action of Buyer, including
1040.10 Output 560PW 220PW 560PW 220PW 560PW 220PW 560PW 220PW
but not limited to improper installation, improper interfacing, improper
Laser
IEC Class 2 Class 1 Class 2 Class 1 Class 2 Class 1 Class 2 Class 1 repair, unauthorized modification, misapplication and mishandling, such as
Class
60825-1 exposure to excessive current, heat, coldness, moisture, vibration or
Output 560PW 220PW 560PW 220PW 560PW 220PW 560PW 220PW
Detection distance outdoors air. Components which wear are not warranted.
(Amplifier display 20 to 45 mm 55 to 130 mm 160 to 450 mm 200 to 1000 mm (2) KEYENCE is pleased to offer suggestions on the use of its various
(250 to 0) (750 to 0) (290 to 0) (800 to 0) Products. They are only suggestions, and it is Buyer's responsibility to
value*1)
Amplifier ascertain the fitness of the Products for Buyer’s intended use. KEYENCE
259 to -34 768 to -98 295 to -50 810 to -175
display range will not be responsible for any damages that may result from the use of the
20 mm (Detection Products.
distance 200 to (3) The Products and any samples ("Products/Samples") supplied to Buyer are
Standard
800 mm), not to be used internally in humans, for human transportation, as safety
detection 0.5 mm 1 mm 3 mm
30 mm (Detection
deviation devices or fail-safe systems, unless their written specifications state
distance 800 to
1000 mm) otherwise. Should any Products/Samples be used in such a manner or
Approx. I0.1 mm Approx. I0.3 mm Approx. I0.8 mm Approx. I1.8 mm misused in any way, KEYENCE assumes no responsibility, and additionally
Spot diameter (Detection distance (Detection distance (Detection distance (Detection distance Buyer will indemnify KEYENCE and hold KEYENCE harmless from any
45 mm) 130 mm) 450 mm) 1000 mm) liability or damage whatsoever arising out of any misuse of the Products/
Operation Control output: Red LED Samples.
status Laser radiation emission indicator: Green LED (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
indicators Other: Green LED
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
Enclosure
IP67 EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
rating
Surrounding air WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
-10 to +50°C (No freezing)
Environmental resistance

temperature FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT


Relative OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
35 to 85% RH (No condensation)
humidity IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE
Incandescent 10,000 5,000 10,000 5,000 5,000 2,500 5,000*2 2,500 *3 LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
Surrounding light

lamp lx lx lx lx lx lx lx lx INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES


20,000 10,000 20,000 10,000 10,000 5,000 10,000*2 5,000 *3 (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING
Sunlight FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF
lx lx lx lx lx lx lx lx
10 to 55 Hz, INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF
Vibration
1.5 mm double amplitude in the X, Y, and Z directions, PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
2 hours respectively SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR
Housing material: PBT Packing: NBR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE
Housing Display: Polyarylate OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE
Material

Metal part: SUS304 OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD
Lens cover Glass PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
Cable PVC BUYER. In some jurisdictions, some of the foregoing warranty disclaimers
Cable length 2m 3m or damage limitations may not apply.
Weight*4 Approx. 120 g Approx. 130 g Approx. 190 g Approx. 210 g

*1 Guideline of the amplifier display value when the distance display for the BUYER'S TRANSFER OBLIGATIONS:
detection distance is set to "nor".
If the Products/Samples purchased by Buyer are to be resold or delivered
*2 For GV-H1000, when the response speed is set to 10 ms or less,
Incandescent lamp: 5,000 lx, Sunlight: 3,000 lx to a third party, Buyer must provide such third party with a copy of this
*3 For GV-H1000L, when the response speed is set to 10 ms or less, document, all specifications, manuals, catalogs, leaflets and written
Incandescent lamp: 2,500 lx, Sunlight: 1,500 lx information provided to Buyer pertaining to the Products/Samples.
*4 Including the connector cable.
E 1101-3

„ Sensor amplifier
Item Specifications
NPN output GV-21 GV-22
Model
PNP output GV-21P GV-22P
Amplifier type Main unit Expansion unit
Power voltage*1 10-30 VDC, Ripple (P-P): 10% max, Class 2
Normal: 2200 mW max. (at 30 V: 73.3 mA max.)
Power consumption Eco-bar: 1700 mW max. (at 30 V: 56.7 mA max.)
Eco-all: 1600 mW max. (at 30 V: 53.3 mA max.)
Response time 1.5/3/10/20/50 ms
NPN (PNP) open collector x 2ch, 40 V (30 V) DC max.
Control output
Max. 100 mA, residual voltage 1 V max.
Purple line.... Laser emission stop input
Pink line ....... Setting value bank switching input/
Control input
shift input/timing input (selected with
the settings)
Surrounding air
-10 to +55°C (No freezing)
temperature
Environmental Relative
35 to 85% RH (No condensation)
resistance humidity
10 to 55 Hz, 1.5 mm double amplitude in the X, Y,
Vibration
and Z directions, 2 hours respectively
Housing material, front sheet: Polycarbonate
Material Key top: Polyacetal
Cable: PVC
Weight*2 Approx. 110 g

*1 11 to 30 VDC when amplifiers are extended.


*2 Including the cable (2 m). Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
11664E 1022-2 96M11664 Printed in Japan

GV-IM-E 10