From: OSL, Software, Support

To: GIBBINGS, Vicard (Massy WG)


Subject: RE: Case 254563: Phast Model Enquiries!
Date: Monday, November 19, 2018 6:28:50 PM
Attachments: image001.jpg
image002.gif
Adding material from DIPPR database in Phast 7.pdf

Vicard,
Thank you for contacting DNV GL Software Support.
1. Phast is a pure consequence modeling tool so it does not calculate the likelihood of the
consequences. It simply gives all the possible effects, and each of them are modeled in
parallel. For fires and explosions, it assumes the ignition is everywhere as the probability of
ignition is not modeled. The user, as the analyst, has to evaluation which effects are more
possible, for example, if there is any immediate ignition to cause jet fire, if there is any
possibility for a delayed ignition in the path of the flammable dispersion cloud to cause a flash
fire, or a possible explosion if there is congestion. Therefore, this is really a question to the
analyst to be evaluated on a case-by-case basis.
2. You may add new components to the default materials list, and I have attached a document
on the topic. Note the new materials you added this way may not contain all needed property
data, and you will need to fill in all the missing data to be able to model it in the software, as
DNV GL has already provided all data we have and we are not able to assist on finding missing
information. Whether to include all components is also a judgement call, but the general rule
here for the mixture is to make it simple by just keeping the most representative components,
and I would perhaps just exclude them if their presence in the mixture is negligible.
Hope this helps.
Best regards,
for DNV GL USA, Inc.

Ji Chen
Technical Support Engineer, Plant Technical Support & Training
DNV GL - Digital Solutions
DNV GL USA, Inc.
[email protected]
Direct +1-281-396-1207
dnvgl.com | LinkedIn

DNV GL

From: GIBBINGS, Vicard (Massy WG) <[email protected]>


Sent: Monday, November 19, 2018 8:25 AM
To: OSL, Software, Support <[email protected]>
Subject: Case 254563: Phast Model Enquiries!
Importance: High
Good-day,
Hope you are doing well. My main aim was to obtain pool fire scenarios for different vessel volumes.
However, as I conducted my different scenarios for different vessels for pool fire, I saw that the other
cases such as ‘Explosion, Jet Fire, and Flash Fires” were also displayed in the result. Therefore:
1. Does the result indicate that other consequences are likely? If so, how do you determine which is
most credible?
2. Secondly, I understand that Phast does not display all component for Materials, however, can it be
assumed that the main components are conservative for modelling? For example, in my mixture –
there should have been components such as i-pentane, 2,2-dimethylpropane, etc.
Kind regards,

Vicard Gibbings
Process Engineer I

6A Queen’s Park West, Victoria Avenue


Port of Spain, Trinidad & Tobago
T +1 868 625 6810 Ext 8642
M +1 868 485 7944
F +1 868 624 3514 Ext 8205
massywoodgroup.com

This message is the property of John Wood Group PLC and/or its subsidiaries and/or affiliates and is
intended only for the named recipient(s). Its contents (including any attachments) may be confidential,
legally privileged or otherwise protected from disclosure by law. Unauthorized use, copying, distribution or
disclosure of any of it may be unlawful and is strictly prohibited. We assume no responsibility to persons
other than the intended named recipient(s) and do not accept liability for any errors or omissions which
are a result of email transmission. If you have received this message in error, please notify us
immediately by reply email to the sender and confirm that the original message and any attachments and
copies have been destroyed and deleted from your system.

If you do not wish to receive future unsolicited commercial electronic messages from us, please forward
this email to: [email protected] and include “Unsubscribe” in the subject line. If applicable, you
will continue to receive invoices, project communications and similar factual, non-commercial electronic
communications.

Please click http://www.woodplc.com/email-disclaimer for notices and company information in relation to


emails originating in the UK, Italy or France.

As a recipient of an email from a John Wood Group Plc company, your contact information will be on our
systems and we may hold other personal data about you such as identification information, CVs, financial
information and information contained in correspondence. For more information on our privacy practices
and your data protection rights, please see our privacy notice at
https://www.woodplc.com/policies/privacy-notice

**************************************************************************************
This e-mail and any attachments thereto may contain confidential information and/or information protected by intellectual property
rights for the exclusive attention of the intended addressees named above. If you have received this transmission in error, please
immediately notify the sender by return e-mail and delete this message and its attachments. Unauthorized use, copying or further
full or partial distribution of this e-mail or its contents is prohibited.
**************************************************************************************

You might also like