Gl100e Installation Manual

This document provides installation instructions for a Kinco HMI device. It describes connecting the power supply to the DC24V and GND terminals and grounding to the FG terminal. It lists environmental requirements such as an operating temperature of 0-50°C and protection from sunlight, moisture, dust and electromagnetic interference. It also details the pin assignments for the COM0/COM2 ports which support various communication protocols like RS232, RS422 and RS485.

Uploaded by

John William
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views1 page

Gl100e Installation Manual

This document provides installation instructions for a Kinco HMI device. It describes connecting the power supply to the DC24V and GND terminals and grounding to the FG terminal. It lists environmental requirements such as an operating temperature of 0-50°C and protection from sunlight, moisture, dust and electromagnetic interference. It also details the pin assignments for the COM0/COM2 ports which support various communication protocols like RS232, RS422 and RS485.

Uploaded by

John William
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GLIOO /GLIOOE HMI Kinco Connect posit¡ve DC line to the 'DC24V teminal, the DC ground to the 'GND' teminal

Connect posit¡ve DC line to the 'DC24V teminal, the DC ground to the 'GND' teminal and the grcund
line to the 'FG' teminal.

3.External lnterface
lnstal lation lnstruction

ffiffiH
1ry.Y! ¿¡jry]4
jryla,te,"1rrr -.
@

:=
,.i'.!!'i..«l
¡1!:f!:lal§. t1%i
' -'!:t=E=Es
r.-. ffi
:!:
re
:re
@
@ l#

Kinco Electric (Shenzhen) Ltd. = re

Add, Build¡ng 1, No. 6 Langshan 1 st Rd, Hi-tech Park North, Nanshan, Shenzhen, China.
Tel, 0755-26585555Fil, 0755-26616372http: //w.kinco.cn Email, sales@[email protected] oc24v GND FG COMo/COM2 !§3

l.lnstallation Note
1.1 Environmental Requirement
ffi@IIHMEffi
OpeEting tempeEtue: G1100/GL100E HMI can work stably in most induskial enürcnmenb that the
tempeEture between 32'F to122F (0-50'C). @
NEMATaüng: Th¡s Series Hl\4lfrcnband is NEMA 1 rated.

Please do not use in the following places: Pleasetakesh¡elding


measures ¡n the following 3.1 POWER
> Places direct in sunljght
> Surroundingtemperature and humidity beyond the places: Pin# Signal
specifications > Places that exist
DC24V
> Places oftemperature changes sharply and easily electrostatic or other kinds 1

Éuse condensatlon of noise 2 GND

> Places that exist corrosive gas and combustible > Places of strong
3 FG
gas electrcmagnet¡c
> Places of much dust, dirt, salt and iron powder > Places that may be exposed
> Places thatwill be splashed water, oil and drugs to rays 3.2 COM0/COM2
> Plaes near the power Pin assignment of the g-pin male, D-SUB, COi\¡0/COlü2.Note;
1.2 Power Requirement R52324851422 communi€tjon functions are supported by COI\,40.CON42
> lnput voltage:Dol0 V-DC28V supports RS232 communiÉüon function.
> Particularly note that theÉ must be enough distan@ between this product and convertes or switch PC/PLC
mode power supply. Make sure that the input and output cables of that kind equipment are shield PLC (COMO) PLC (COMO) PLC (Cotvfo)
Pin Signal (c0M2)
cable and the shielding network is connected with the ground. IRS 422] IRS 4BE] IRS 232]
> l\,,lake sure that the DC power and AC power is isolated.
IRS 232]
Rx (B) RS422 R
> Do not use @mmon power wür per€ptuai toad or input circuit of the controlier. 1 RS4B5 B

Note: An lntemal fuse w¡ll prevent damage for over voltage condition, however it isn't guaranteed the 2 RxD PLC RS232 RxD
internal electronic components are not damaged. 3 TxD_PLC RS232 TxD

4 T¡- RS422 T
2.lnstallation Description 5 GN]) Signal ground
2.1 Dimensional Draw¡ng 6 Rx+ (A) RS422 R+ RS485 A

7 RxD PC RS232 RxD

8 TxD PC RS2ll2 TxD


35.1 9 Tx+ RS422 T+
5.5

¡l

3,3 USB SLAVE


The interfa€ type is t\¡icrouSB
Cutout Size Connect¡on USB Slave oort can be connected w th a PC
Port The porl is only used to download user configuration program to the HN/l and to
Funct¡on set HMI system parameters.

3.4 USB HOST

interfa€ can be conntrted w¡th USB keyboard, mouse and printere, and
Port
2.2 Fixed Screw lnstallat¡on lnstructions
Funclion
d¡sk cn be used for useas configumtion uploading/ downloading as well
The product is put inio the well mounted hole of the mach¡ne control box's panel, and the mounting
screws are inserted into the fixing holes around the HMI shell from the back of the control box's panel.
Recommended lock torque:0.5N.m (to waterproofeffect and avoid sheli defomation)
3.5 Ethernet(Only GL100E support)
1 0M/100N.4 adaptive Ethemet RJ45 port.
! Connstion With CATs UTP cable connected to the Ethemet devi€.
! The port can be used for upload/download of configuration, setting of
Hl\,41

system paEmetes and onl¡ne simulations of configurations. lt mn connect


Port
multiple HMls via the Ethemet to fom an HMI network. Furthemore, it can
Funcl¡on
implement communimtions between Hl\¡l and PLC via the Ethemet, as well
as communi€tions w¡th a PC via the Ethemet port.

4.After-sales Service
2.3 Power Connect¡on For < Service Terms and Conditions for HMI >, please check:http://www.kinco.cn
Before mnnecling the pNer, pleas make sure all loml and national elec{riGl standards are met.For i
pNer €bls,please select ebl6 with their dieleciric sfength valus and curent values in compliane
w¡th the safety specifiGtions.

FiBt find the pNer teminal at the back of the prcduct and loosen the screw amrding to
munterclmkwise, then insert lhe pffier Gbles and üghten the screw up.

You might also like