ControlNet Router Datasheet
ControlNet Router Datasheet
ControlNet Router
A-CNR
The module can also be configured as a PCCC Client (allows the module to emulate a
PLC5 or SLC5 providing legacy interface to PanelViews), EtherNet/IP target or originator,
and as Modbus TCP/IP client or server.
As an EtherNet/IP target, a Logix controller can own the router using a Class 1
connection. As an EtherNet/IP originator, the router supports class 1 connection or
explicit messaging.
As a Modbus TCP/IP client, the router can map ControlNet data to Modbus registers for
exchange with Modbus TCP/IP servers. As a Modbus TCP/IP server, the router can
exchange the ControlNet data with Modbus TCP/IP clients.
The I/O data can be accessed via Ethernet using either the PCCC or EtherNet/IP™ or
Modbus TCP/IP protocols. The support for PCCC protocol allows the module to emulate
user-defined PLC5-type data files data simplifying the migration to Ethernet-only
PanelViews. The module also provides a range of statistics on Ethernet and ControlNet
to assist with fault finding.
A built-in webserver provides detailed diagnostics of system configuration and operation,
including the display of ControlNet operation and communication statistics, without the
need for any additional software.
Features
Own ControlNet I/O enabling the migration from legacy Logix systems/controllers to newer EtherNet/IP Logix platforms, without replacing the
existing ControlNet I/O.
Can be configured as a ControlNet Target or Originator.
Can operate as ControlNet Keeper.
Supports Promiscuous Capture mode allowing the ControlNet Router to capture all traffic on the ControlNet network.
Can be configured as an EtherNet/IP Target or Originator.
Can be configured as a Modbus TCP/IP Client to exchange ControlNet data with Modbus TCP/IP servers.
Can be configured as Modbus TCP/IP Server to exchange ControlNet data with Modbus TCP/IP clients.
Connect Ethernet-only PanelViews to Logix via ControlNet.
Supports Scheduled & Unscheduled ControlNet for PanelViews.
Program Logix controllers via ControlNet.
Supports Redundant ControlNet and Ethernet.
Advanced Diagnostics, including packet capture and webserver.
Configuration
The Slate Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone configuration utility
allows users to define the setup and configuration of the ControlNet router, connections with controllers and devices.
The configuration utility can be downloaded from www.prosoft-technology.com
Figure 1 - Typical setup for EtherNet/IP Target to
ControlNet I/O
Global Support
ControlNet Target
Specification Description We are there for you
Scheduled Connection Size Max. Input size – 408 bytes (400 bytes of All ProSoft Technology products are
mapped data) backed with free technical support.
Max. Output size – 404 bytes (400 bytes of Contact our worldwide Technical
mapped data) Support team directly by phone or
Unscheduled Routed Clients 40 max. email.
Scheduled Connection Count 1
Global Offices
ControlNet Originator
Description We are where you are
Specification
Scheduled Connection Count 10 max. ProSoft Technology has regional
Scheduled Connection Data 570 bytes (input and output) maximum offices worldwide available to help
10 max. you with all your industrial
Explicit Unscheduled Connections
application needs. If you need help
Multiple ControlNet Connection Supported
choosing a ProSoft Technology
Originators solution for your particular
application check out our contact
information under distributor sales
PCCC on the website at:
Specification Description www.prosoft-technology.com
PCCC Connections 10 max.
PCCC Payload 1000 bytes max.
Whether your application is large or
small, our technical professionals
are there to help you choose the
right communication solution.
EtherNet/IP Target
Specification Description
Class 1 Connection Size Max. Input size – 500 bytes (492 bytes of
mapped data)
Max. Output size – 496 bytes (492 bytes of
mapped data)
Class 1 Connection Count 1
Class 3 Messaging Support Yes
Direct-to-Tag Logix Support Yes Additional Products
ProSoft Technology® offers a full
complement of hardware and
EtherNet/IP Originator software solutions for a wide variety
Specification Description of industrial communication
Class 1 Cyclic Connection Supported Yes platforms. For a complete list of
Class 3 UCMM Connections Supported Yes products, visit our website at:
Class 1 Connection Count 10 www.prosoft-technology.com
Class 3 UCMM Connection Count 10
Class 3 UCMM Mapping Count 50
Direct-To-Tag Logix Support Yes
Ordering Information
To order this product, please use the
Modbus TCP/IP Client following:
Specification Description
Server Devices 20 max.
100 max. per server device
ControlNet Router
Modbus Mappings
Mapping Ranges 0 to 65535
Base Offset Modbus (base 0); PLC (base 1) A-CNR