ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
VDRM/VRRM, MAXIMUM REPETITIVE PEAK VRSM, MAXIMUM IDRM/IRRM MAXIMUM
VOLTAGE
TYPE NUMBER AND OFF-STATE VOLTAGE NON-REPETITIVE PEAK VOLTAGE AT TJ = TJ MAXIMUM
CODE
V V mA
04 400 500
08 800 900
ST330C..C 12 1200 1300 50
14 1400 1500
16 1600 1700
SWITCHING
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum non-repetitive rate of Gate drive 20 V, 20 Ω, tr ≤ 1 µs
dI/dt 1000 A/µs
rise of turned-on current TJ = TJ maximum, anode voltage ≤ 80 % VDRM
Gate current 1 A, dIg/dt = 1 A/µs
Typical delay time td 1.0
Vd = 0.67 % VDRM, TJ = 25 °C
µs
ITM = 550 A, TJ = TJ maximum, dI/dt = 40 A/µs,
Typical turn-off time tq 100
VR = 50 V, dV/dt = 20 V/µs, gate 0 V 100 Ω, tp = 500 µs
BLOCKING
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum critical rate of rise of
dV/dt TJ = TJ maximum linear to 80 % rated VDRM 500 V/µs
off-state voltage
Maximum peak reverse and IRRM,
TJ = TJ maximum, rated VDRM/VRRM applied 50 mA
off-state leakage current IDRM
TRIGGERING
VALUES
PARAMETER SYMBOL TEST CONDITIONS UNITS
TYP. MAX.
Maximum peak gate power PGM TJ = TJ maximum, tp ≤ 5 ms 10.0
W
Maximum average gate power PG(AV) TJ = TJ maximum, f = 50 Hz, d% = 50 2.0
Maximum peak positive gate current IGM TJ = TJ maximum, tp ≤ 5 ms 3.0 A
Maximum peak positive gate voltage + VGM 20
TJ = TJ maximum, tp ≤ 5 ms V
Maximum peak negative gate voltage - VGM 5.0
TJ = - 40 °C 200 -
DC gate current required to trigger IGT TJ = 25 °C 100 200 mA
Maximum required gate trigger/
TJ = 125 °C current/voltage are the lowest 50 -
TJ = - 40 °C value which will trigger all units 2.5 -
12 V anode to cathode applied
DC gate voltage required to trigger VGT TJ = 25 °C 1.8 3.0 V
TJ = 125 °C 1.1 -
Maximum gate current/voltage
DC gate current not to trigger IGD not to trigger is the maximum 10 mA
TJ = TJ maximum value which will not trigger any
DC gate voltage not to trigger VGD unit with rated VDRM anode to 0.25 V
cathode applied
ΔRthJ-hs CONDUCTION
SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION
CONDUCTION ANGLE TEST CONDITIONS UNITS
SINGLE SIDE DOUBLE SIDE SINGLE SIDE DOUBLE SIDE
180° 0.012 0.011 0.008 0.007
120° 0.014 0.012 0.014 0.013
90° 0.017 0.015 0.019 0.017 TJ = TJ maximum K/W
60° 0.025 0.022 0.026 0.023
30° 0.043 0.036 0.043 0.037
Note
• The table above shows the increment of thermal resistance RthJ-hs when devices operate at different conduction angles than DC
130 130
ST330C..C Series ST330C..C Series
120 (Double Side Cooled)
(Single Side Cooled)
120 RthJ-hs (DC) = 0.09 K/ W 110 RthJ-hs (DC) = 0.04 K/ W
100
110 90
80 Conduction Period
Conduction Angle
100 70 30°
60 60°
30°
90 60° 50 90°
90°
40 120°
120°
180°
80 180° 30
20 DC
70 10
0 50 100 150 200 250 300 350 400 0 200 400 600 800 1000 1200 1400 1600
130 1800
ST330C..C Series DC
120 (Double Side Cooled) 1600 180°
110 RthJ-hs (DC) = 0.04 K/ W 120°
1400 90°
100 60°
1200 30°
90
80 Conduction Angle 1000 RMSLimit
70 800
60 Conduction Period
600
50 30° 60°
90° 400
40 120° ST330C..C Series
180°
30 200 TJ = 125°C
20 0
0 200 400 600 800 1000 0 200 400 600 800 1000 1200
8000 9000
At Any Rated Load Condition And With Maximum Non Repetitive Surge Current
7500 Rated VRRM Applied Following Surge. 8500 Versus Pulse Train Duration. Control
Initial TJ = 125°C 8000 Of Conduc tion May Not Be Maintained.
7000 @60 Hz 0.0083 s Initial TJ = 125°C
@50 Hz 0.0100 s 7500
No Voltage Reapplied
6500 7000 Rated VRRM Reapplied
6000 6500
5500 6000
5500
5000
5000
4500
4500
ST330C..C Series ST330C..C Series
4000 4000
3500 3500
1 10 100 0.01 0.1 1
Number Of Equal Amplitude Half Cycle Current Pulses (N) Pulse Train Duration (s)
Fig. 7 - Maximum Non-Repetitive Surge Current Fig. 8 - Maximum Non-Repetitive Surge Current
Single and Double Side Cooled Single and Double Side Cooled
10000
TJ = 25°C
Instantaneous On-state Current (A)
TJ = 125°C
1000
ST330C..C Series
100
0 1 2 3 4 5 6 7
Instantaneous On-state Voltage (V)
0.1
Transient Thermal Impedance Z thJ-hs (K/ W)
ST330C..C Series
0.001
0.001 0.01 0.1 1 10
Square Wave Pulse Duration (s)
100
Rectangular gate pulse (1) PGM = 10W, tp = 4 ms
a) Recommended load line for (2) PGM = 20W, tp = 2 ms
Tj=-40 °C
Tj=25 °C
Tj=125 °C
1
(1) (2) (3) (4)
VGD
IGD
Device: ST330C..C Series Frequency Limited by PG(AV)
0.1
0.001 0.01 0.1 1 10 100
Instantaneous Gate Current (A)
1 2 3 4 5 6 7 8 9
1 - Thyristor
2 - Essential part number
3 - 0 = Converter grade
4 - C = Ceramic PUK
5 - Voltage code x 100 = VRRM (see Voltage Ratings table)
6 - C = PUK case TO-200AB (E-PUK)
7 - 0 = Eyelet terminals (gate and auxiliary cathode unsoldered leads)
1 = Fast-on terminals (gate and auxiliary cathode unsoldered leads)
2 = Eyelet terminals (gate and auxiliary cathode soldered leads)
3 = Fast-on terminals (gate and auxiliary cathode soldered leads)
8 - Critical dV/dt: None = 500 V/µs (standard selection)
L = 1000 V/µs (special selection)
9 - Lead (Pb)-free
TO-200AB (E-PUK)
Anode to gate
Creepage distance: 11.18 (0.44) minimum
Strike distance: 7.62 (0.30) minimum
25.3 (0.99)
DIA. MAX.
0.3 (0.01) MIN.
14.1/15.1
(0.56/0.59)
6.5 (0.26)
4.75 (0.19)
25° ± 5°
42 (1.65) MAX.
28 (1.10)
Quote between upper and lower pole pieces has to be considered after
application of mounting force (see thermal and mechanical specification)
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Authorized Distributor
Vishay:
ST330C12L0L ST330C16L0L ST330C16L1L ST330C12C0L ST330C12C1L ST330C14C0L ST330C14C1L
ST330C16C0L ST330C16C1L VS-ST330C08C0 VS-ST330C12C0 VS-ST330C12L0 VS-ST330C14C0 VS-
ST330C16C0 VS-ST330C14L1 VS-ST330C16L0 VS-ST330C04C0 VS-ST330C14L0 VS-ST330C08L0 VS-
ST330C04L1 VS-ST330C14C1 VS-ST330C16C1 VS-ST330C04C1 VS-ST330C04L0 VS-ST330C08C1 VS-
ST330C08L1 VS-ST330C12L1 VS-ST330C16L1 VS-ST330C12C1 VS-ST330C16C3