G6RN
G6RN
RoHS Compliant
1
G6RN PCB Power Relay
■Engineering Data
●Maximum Switching Capacity ●Durability ●Ambient Temperature vs.
Maximum Coil Voltage
Switching current (A)
0.5 100
3
0.3
80
0.1 1 0
0 3 5 10 30 50 100 250 500 0 2 4 6 8 10 -40 20 23 30 40 50 60 70 80 90 100
Switching Voltage (V) Switching Current (A) Ambient Temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●Ambient Temperature vs. ●Shock Malfunction
Maximum Coil Voltage G6RN-1
Y
Operate/Release voltage (percentage of rated value) (%)
100
Sample: Must operate voltage 1,000 Sample: G6RN-1 24 VDC
contact A
G6RN-1 12 VDC Must release voltage Number of Relays: 5 pcs
G
Number of Relays: Test conditions: The value at which
80 5 pcs
6 max. X Z malfunction occurred was measured
R X
1,000 1,000 after applying shock to the test piece 3
min. times each in 6 directions along 3 axes.
N 60
88.2 Standard value: 100m/s2 at contact A,
contact B 50m/s2 at contact B
40
1,000 1,000
Z' X'
max.
X
20 min. Shock direction
X X'
1,000 Unit: m/s2 Y
Y' Z
0 Z'
-40 -20 0 20 40 60 80 100
Y'
Ambient Temperature (°C)
■Dimensions
G6RN-1 PCB Mounting Holes Terminal Arrangement/
(Bottom View) Internal Connections
(Bottom View)
10±0.5
28.5±0.5 Five, 1.3-dia. holes
(1.19)
1 2
15±0.5 3.5 7.62±0.1
0.5
(1.19) 5 4 3
3.2 7.62 19±0.1 (1.5) (No coil polarity)
(1.6) 3.2±0.1 3.2±0.1
19 3.2
(1.19)
1 2
15±0.5 3.5 7.62±0.1
0.5
(1.19) 5 3
19 5.1 7.62 19±0.1
(1.6) 5.1±0.1 (2.8) (No coil polarity)
2
G6RN PCB Power Relay
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalog.
UL Recognized (File No. E41515)
CSA Certified (File No. 31928)
Number of Number of test
Model Coil ratings Contact ratings
poles operations
8 A, 250 VAC 85°C
G6RN-1 1 5 to 24 VDC 6,000
8 A, 30 VDC 85°C
Creepage distance 8 mm
Clearance distance 8 mm
Insulation material group IIIa
Rated Insulation voltage 250 V
Pollution degree 2
Rated voltage system 250 V
Overvoltage category III
Tracking Index of relay base PTI 250 V min. (housing parts)
Flammability class according to UL94 V-0
Ball pressure test (IEC 60695-10-2) 160°C G
6
R
■Precautions N
●Please refer to “PCB Relays Common Precautions” for correct use.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J182-E1-04
1116(0207)(O)