G6RN

This document provides specifications for the G6RN miniature power relay for switching 8A. Some key details: 1. The G6RN relay is small in size at 15mm height but can switch 8A at 250VAC. 2. It has high sensitivity consuming only 220mW of power. 3. The relay provides high insulation with a 8mm insulation distance and 10kV impulse withstand voltage between coil and contacts. 4. It is rated for an ambient operating temperature of 85°C.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views3 pages

G6RN

This document provides specifications for the G6RN miniature power relay for switching 8A. Some key details: 1. The G6RN relay is small in size at 15mm height but can switch 8A at 250VAC. 2. It has high sensitivity consuming only 220mW of power. 3. The relay provides high insulation with a 8mm insulation distance and 10kV impulse withstand voltage between coil and contacts. 4. It is rated for an ambient operating temperature of 85°C.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

G6RN

PCB Power Relay

Miniature Power Relay for


Switching 8 A
• Low-profile height of 15 mm (approx. 60% the height of the Omron
G2R model).
• Capable of switching with 8 A at 250 VAC despite its small size.
• High sensitivity with 220mW power consumption.
• Offers high insulation with insulation distance of 8 mm and impulse
withstand voltage of 10kV between coil and contacts.
• Satisfies ambient operating temperature requirement of 85°C.
• Standard model conforms to VDE standards.

RoHS Compliant

■Model Number Legend ■Application Examples


G 6 R N -@ @ • Control equipments
——
1 2 G
■Characteristics 6
1. Number of Poles 2. Contact Form
R
1: 1-pole None: SPDT (1c) Contact resistance *1 100 mΩ max. N
A: SPST-NO (1a) Operate time 15 ms max.
Release time 5 ms max.
■Ordering Information Insulation resistance *2
Between
1,000 MΩ min.

coil and 4,000 VAC, 50/60 Hz for 1 min


Enclosure Rated coil Minimun contacts
Classification Contact form Terminal shape Model Dielectric
rating voltage packing unit Between
5, 6, 12 VDC strength
SPST-NO (1a) G6RN-1A contacts of
1,000 VAC, 50/60 Hz for 1 min
PCB 24 VDC the same
Standard Fully sealed 20 pcs/tube
terminals 5, 6, 12 VDC polarity
SPDT (1c) G6RN-1 Impulse withstand
24 VDC
voltage (between coil 10,000 V (1.2 x 50 μs)
Note. When ordering, add the rated coil voltage to the model number. and contacts)
Example: G6RN-1A DC5 Between
Insulation Clearance: 8 mm,
Rated coil voltage coil and
However, the notation of the coil voltage on the product case will be marked as @@VDC. distance Creepage: 8 mm
contacts
10 to 55 to 10 Hz, 0.75 mm
Destruction single amplitude
■Ratings Vibration
(1.5 mm double amplitude)
10 to 55 to 10 Hz
resistance NO: 0.75 mm single amplitude
●Coil Malfunction (1.5 mm double amplitude)
Item Must operate Must release Max. NC: 0.4 mm single amplitude
Rated Coil Power
voltage voltage voltage (0.8 mm double amplitude)
current resistance consumption
(V) (V) (V) Destruction 1,000 m/s2
(mA) (Ω) (mW) Shock
Rated voltage % of rated voltage NO: 100 m/s2
resistance Malfunction
5 VDC 43.9 114 NC:: 50 m/s2
6 VDC 36.6 164 150% 10,000,000 operations min.
70% max. 10% min. Approx. 220 Mechanical
12 VDC 18.3 655 (at 23°C) (at 36,000 operations/hr)
50,000 operations min.
24 VDC 9.2 2,620
(8 A at 250 VAC, resistive load)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of Durability
50,000 operations min.
±10%. Electrical *3
(5 A at 30 VDC, resistive load)
*2. The operating characteristics are measured at a coil temperature of 23°C. (at 360 operations/hr under
*3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. rated load)
●Contacts Failure rate (P level)
10 mA at 5 VDC
(reference value) *4
Load Ambient operating -40°C to 85°C (with no icing or
Resistive load
Item temperature condensation)
Contact type Single Ambient operating
5% to 85%
Ag-Alloy + gold plating humidity
Contact material
(Cd free) Weight Approx. 9 g
8 A at 250 VAC Note. The data given above are initial values.
Rated load
5 A at 30 VDC *1. Measurement conditions: 5 VDC, 1 A, voltage drop
Rated carry method.
8A
current *2. Measurement conditions: The insulation resistance
Max. switching was measured with a 500 VDC megohmmeter at the
250 VAC, 30 VDC
voltage same locations as the dielectric strength was
Max. switching measured.
8A
current *3. Test conditions: With diode
*4. This value was measured at a switching frequency of
120 operations/min.

1
G6RN PCB Power Relay

■Engineering Data
●Maximum Switching Capacity ●Durability ●Ambient Temperature vs.
Maximum Coil Voltage
Switching current (A)

Maximum coil voltage (%)


Durability (x 104 operations)
100 200
250 VAC resistive load
50 30 VDC resistive load
30 50 180

DC resistive load AC resistive load 30


10 160
8 150
5
140
3 10 130
120
1 5 110

0.5 100
3
0.3
80

0.1 1 0
0 3 5 10 30 50 100 250 500 0 2 4 6 8 10 -40 20 23 30 40 50 60 70 80 90 100
Switching Voltage (V) Switching Current (A) Ambient Temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●Ambient Temperature vs. ●Shock Malfunction
Maximum Coil Voltage G6RN-1
Y
Operate/Release voltage (percentage of rated value) (%)

100
Sample: Must operate voltage 1,000 Sample: G6RN-1 24 VDC
contact A
G6RN-1 12 VDC Must release voltage Number of Relays: 5 pcs
G
Number of Relays: Test conditions: The value at which
80 5 pcs
6 max. X Z malfunction occurred was measured
R X
1,000 1,000 after applying shock to the test piece 3
min. times each in 6 directions along 3 axes.
N 60
88.2 Standard value: 100m/s2 at contact A,
contact B 50m/s2 at contact B
40
1,000 1,000
Z' X'
max.
X
20 min. Shock direction
X X'
1,000 Unit: m/s2 Y
Y' Z
0 Z'
-40 -20 0 20 40 60 80 100
Y'
Ambient Temperature (°C)

■Dimensions
G6RN-1 PCB Mounting Holes Terminal Arrangement/
(Bottom View) Internal Connections
(Bottom View)
10±0.5
28.5±0.5 Five, 1.3-dia. holes

(1.19)
1 2
15±0.5 3.5 7.62±0.1
0.5
(1.19) 5 4 3
3.2 7.62 19±0.1 (1.5) (No coil polarity)
(1.6) 3.2±0.1 3.2±0.1
19 3.2

G6RN-1A PCB Mounting Holes Terminal Arrangement/


(Bottom View) Internal Connections
10±0.5 (Bottom View)
28.5±0.5 Four, 1.3-dia. holes

(1.19)
1 2
15±0.5 3.5 7.62±0.1
0.5
(1.19) 5 3
19 5.1 7.62 19±0.1
(1.6) 5.1±0.1 (2.8) (No coil polarity)

2
G6RN PCB Power Relay

■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalog.
UL Recognized (File No. E41515)
CSA Certified (File No. 31928)
Number of Number of test
Model Coil ratings Contact ratings
poles operations
8 A, 250 VAC 85°C
G6RN-1 1 5 to 24 VDC 6,000
8 A, 30 VDC 85°C

EN/TÜV Certified (Certificate No. 6135)


Number of Approved switching
Model Coil ratings Contact ratings
poles operations
G6RN-1 8 A, 250 VAC (Resistive)
1 5, 6, 12, 24 VDC 10,000
G6RN-1A 85°C

Creepage distance 8 mm
Clearance distance 8 mm
Insulation material group IIIa
Rated Insulation voltage 250 V
Pollution degree 2
Rated voltage system 250 V
Overvoltage category III
Tracking Index of relay base PTI 250 V min. (housing parts)
Flammability class according to UL94 V-0
Ball pressure test (IEC 60695-10-2) 160°C G
6
R
■Precautions N
●Please refer to “PCB Relays Common Precautions” for correct use.

• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.

Note: Do not use this document to operate the Unit.

OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J182-E1-04
1116(0207)(O)

You might also like