A detailed structural analysis has been carried out on design of the PMU CURTIAN WALL EWS101,
for CERTIS CENTRE DEVELOPMENT PROJECT at GEYLANG, SINGAPORE
A.2. REFERENCES
The major intention codes and standards utilized during preparation of these calculations include:
SS EN 1990 - 2008 Basis of structural design
SS EN 1991 - 1-1 : 2008 Action on Structures Part 1-1 : Densities, self-weight, imposed loads for building
SS EN 1993 - 1-1 : 2010 Design of Steel Structures Part 1-1 : General rules & rules for buildings
SS EN 1992 - 1-1 : 2008 Design of Concrete Structures Part 1-1 : General rules & rules for buildings
BS EN ISO 3506 Mechanical Properties of Corrosion Resistant Stainless Steel Fasteners Part 1: Bolts, Screw and
Studs
AS 1288-2006 Glass in buildings - Selection and installation
Carbon Steel
TensileYield Strength Shear Yield Strength
Steel Grade Young's Modulus (GPa)
(MPa) (MPa)
S275 275 165 200
Aluminium Extrusion
Tensile Yield Strength Shear Yield Strength Bearing Yield Young's Modulus
Aluminium Alloy
(MPa) (MPa) Strength (MPa) (GPa)
3003-H14 110 65 165 70
6063-T5 110 65 179 70
6063-T6 160 95 276 70
6061-T6 240 145 386 70
2
Stainless Steel Machine Screws & Bolts
Structural Sealant
Tensile Strength
Structural Sealant Type
(MPa)
Structural Sealant 138
3
A4.3 Live Load due to Human Load
1.50kN//m @FFL+1.1m above@ Areas where people may congregate; 3.0kN/m @FFL + 1.1m above @
Areas susceptible for overcrowded;0.75kN/m for private occupancy
4
1. 3D PMU Configuration and Loads
7325mm
7325mm
The PMU is 2.5-storey high and 5 bays wide, with corner returns as per specification.
5
2. Glass analysis
1505mm
2833mm
Derivation Load
Load applied on each pane - Outer Lite=1.38*ko=0.20kPa
Load applied on each pane - Inner Lite=1.38*ki=1.60kPa
Point load for human impact at 1.1m height
Refer to Combined Load Case
Load Case 1 : DL + WL
Load Case 2 : DL + PL (Inner lite only)
Load Case 1 : DL + WL+PL(Inner lite only)
6
Check for Stress & Deflection
Refer to Clause 3.3.2 Ultimate design strength
Outer Lite 6 mm HS Monolithic Glass
Capacity reduction factor=0.67
Glass type factor - Table 3.1 c1=1.6 for Heat Strengthened
Surface type factor - Table 3.2 c2=1.0 for Flat Glass
Load duration factor - Table 3.3 c3=1.0 for Short term load duration
Characteristic tensile strength, ft=(-7.88 ln(5.8)+57.07)=43MPa
Nominal capacity - Ultimate design=0.67*1.6*1.0*1.0=46MPa
Limiting deflection=1505/90=16.7mm
Refer to Structural Model Analysis - Strand7
7
Inner Lite 13.52 mm HS, Laminated Glass
Refer to Clause 3.3.2 Ultimate design strength
Capacity reduction factor =0.67
Glass type factor - Table 3.1 c1=1.6 for Heat Strengthened
Surface type factor - Table 3.2 c2=1.0for Flat Glass
Load duration factor - Table 3.3 c3=1.0 for Short term load duration
Characteristic tensile strength=37MPa
Nominal capacity - Ultimate design=40MPa
Limiting deflection=16.7mm
Refer to Structural Model Analysis - Strand7
Load Factored - 1.5DL+1.5WL
8
Load Factored - 1.2DL+1.6PL
1.1kN
1.1m
9
Load Factored - 1.2DL+1.2WL+1.2PL
10
Check sealant
Basic Data
Short side length of glass panelof largest size=1.505m
Maximum wind suction=1.38kPa
Design thickness of sealant between glass and sub-frame=6.4mm
Design width of sealant between glass and sub-frame=14.5mm,9mm and 13mm
Allowable stress of sealant fs.al 0.138MPa
13mm
11
1.2 Spandrel glass
IGU 25.52mm (GS01-6mm HS Monolithic Glass +12AS+6mm HS Monolithic Glass)
AS 1288-2006 Glass in buildings - Selection and installation
1367mm
1505mm
Dimension of Glass
design wind pressure
glass longer side=1.367m
glass shorter side=1.505m
glass thickness - outer lite=6mm
glass thickness - inter lite=6mm
Refer to Table 4.1
min thickness - outer lite=5.8mm
min thickness - inter lite=5.8mm
glass modulus of elasticity Eglass 70GPa
Refer to Clause 3.4.2 Insulating glass units (IGU)
Share loading factor - Outer Lite=1.25*to3/(to3+ti3)=0.625
Share loading factor - Inner Lite=1.25*ti3/(to3+ti3)=0.625
Derivation Load
Load applied on each pane - Outer Lite=1.38*0.625=0.863kPa
Load applied on each pane - Inner Lite=1.38*0.625=0.863kPs
Point load for human impact at 1.1m height
Refer to Combined Load Case
Load Case 1 : DL + WL
1367mm
13
Check sealant
Basic Data
Short side length of glass panelof largest size=1.367m
Maximum wind suction=1.38kPa
Design thickness of sealant between glass and sub-frame=6.4mm
Design width of sealant between glass and sub-frame=14.0mm and 10mm
Allowable stress of sealant fs.al 0.138MPa
14
3. Back pan analysis
The aluminium panel grade 3003-H14 of size -1370x1275 mm (top panel) -was analyzed by the finite
element software Strand 7 under design wind load +1.12/-1.38 kPa. The panels are 1.5 mm thick and are
fixed at 4 sides to the aluminium framing member by using screw no 4.20F spacing 300mm. The aluminium
stiffeners added at the 425 mm spacing (aluminium c-channel 60x40x3mm ) of the aluminium panel to
reduce the deflection.
Self-weight of the panel is automatically incorporated by the software. The stress induced and
deflection is determined using finite element plate analysis in Strand 7 program. From the nonlinear
analysis, the maximum Von-Mises stress and deflections are:
screw #10 (no. 4.04) =A2-70 spacing 300mm
300mm
300mm
C-Channel 60x40x3mm
C-Channel
60x40x3mm
1275mm
425mm
425mm
1370mm
Positive
Negative wind=
wind=+1.12kPa
-1.38kPa
16
max = 9.9 mm
According to specifications:
Limiting deflection lim = 1275/90
= 14.1 mm > max
Since allow = 100 MPa > max = 75.9 MPa and max = 9.9 mm, aluminium panel satisfies both serviceability
and strength criteria.
1275mm
Positive
wind=+1.12kPa
Negative wind=
-1.38kPa
Screw check
Positive
wind=+1.12kPa
Shear capacity of screw #10 (no. 4.04, diameter=4.8mm) =A2-70 spacing 300mm
Effective area=9.8mm2; shear strength=311MPa;
Shear capacity=9.8mm2*311MPa=3kN > 1.5*0.4=0.60kN……OK
Bearing of A2-70=805MPa*1.5*4.8mmmm2=5.7kN > Max. Resultant=1.5*0.4=0.6kN …OK
Bearing on aluminium3003-H14=4.8*1.5mm 2*165MPa/1.1=1.1kN >Max. Resultant=1.5*0.4=0.6kN …OK
17
Verification of aluminium stiffener-Channel 60x40x3mm grade 6063-T5
The alum stiffener grade 6063-T5, which is located at sketch. The alum cladding panel is attached to this
stiffener using structural silicone.
From the non-linear analysis, the maximum stress of the aluminium stiffener (grade 6063-T5) is:
1370mm
Allowable design tensile stress of silicone without rotation, a= 138 kPa
Total silicon bite, Hmc = 2*6=12mm
Allowable Tension force, Fallow = 138 x 0.012 x 1.37 = 2.269 kN
Utility of silicon capacity, = 0.804 / 2.269=0.36 < 1.0 o.k.
18
4. Aluminium frames analysis
EN 1999-1-1 : 2000 Eurocode 9 : Design of aluminium structures : Part 1-1 : General rules
EN 1991-1-1:2007 Enrocode 9: Design of aluminium structures - Part 1-1 : General structural rules
4.1.1 Aluminium Extrusion - Alloy 6063-T6 for Male & female mullion, head and sill
4.1.3 Aluminium Extrusion - Alloy 6061-T6 for Flat bar (Sunshade bracket), slot bracket,
hook bracket and floor bracket,
19
4.1.6 Local buckling resistance
There are 3 types of corner panel, typical curtain wall-without sunshade and with sunshade. Curtain
wall corner and typ. with sunshade, the maximum width=1,505mm. Typical mullion without
sunshade, the maximum width=1,450mm. The computer models are continuous beam which start
from 1st storey to 2.0nd storey, 2.5 floors. The distance between stack joint and centre of bolts fixing
is 145.82mm as per recommendation’s facade consultant. The length of sunshade is 600mm.
20
Dead load=3kN
Type 2
Dead load on
sunshade Type 3
Type 1
21
Load case 3: Negative wind -1.38kPa
22
4.1.8 Verification of corner mullions, bending moment and deflection
Male Female
23
4.2m
24
4.1.9 Verification of typical mullion, bending moment and deflection
Male Female
25
4.2m
26
4.2 Corner male mullion CR-23-analysis
27
28
29
30
31
Factored corner male bending moment,
1.5Mm=1.5*mMmax =1.5*1.8=2.7kNm < MR_min….OK
32
Factored corner male bending moment,
1.5Mm=1.5*mMmax =1.5*1.8=2.7kNm < MLB….OK
Therefore, Aluminium Corner Male Mullion is structurally adequate from Design Load.
33
34
35
36
37
Factored corner female bending moment,
1.5Mf=1.5*fMmax =1.5*1.7=2.6kNm < MR_A….OK
38
Factored corner female bending moment,
1.5Mf=1.5*fMmax =1.5*1.7=2.6kNm < MR_min….OK
39
Factored corner female bending moment,
1.5Mf=1.5*fMmax =1.5*1.7=2.6kNm < MLB….OK
Therefore, Aluminium Corner Female Mullion is structurally adequate from Design Load.
40
4.4 Male mullion CR-01-analysis
41
42
A. Flat outstand with no stress gradient (under uniform compression)
3mm
Moment=40,481.6mm3*160MPa/1.1=5.9kNm
Moment=42,168.1mm3*160MPa/1.1=6.1kNm
43
C. Classification of cross-section - Moment Resistance of lateral Torsional Buckling
2833mm
Utilization=3.2/5.9=0.55 or 55%
44
4.5 Female mullion, CR-02 analysis
45
Section properties of Effective section
46
A. Flat outstand with no stress gradient (under uniform compression)
Moment=35,326mm3*160MPa/1.1=5.1kNm
47
B. Unreinforced Flat Internal Element under Uniform Compression
Moment=37,478mm3*160MPa/1.1=5.5kNm
48
C. Classification of cross-section - Moment Resistance of lateral Torsional Buckling
2833mm
Utilization=2.9/5.1=0.56 or 56%
49
4.6 Head transom, CR-03 analysis
50
Section properties of Effective section
51
A. Flat outstand with no stress gradient (under uniform compression)
Moment=54,034mm3*160MPa/1.1=7.9kNm
52
B. Unreinforced Flat Internal Element under Uniform Compression
Moment=60,491mm3*160MPa/1.1=8.8kNm
53
C. Unreinforced Flat Internal Element under Stress Gradient
Moment=60,491mm3*160MPa/1.1=8.8kNm
54
D. Unreinforced Flat Outstand Element under Stress Gradient
Moment=54,034mm3*160MPa/1.1=7.9kNm
55
E. Classification of cross-section - Moment Resistance of lateral Torsional Buckling
1505mm
56
G. Analysis of bending moment and defection
2833mm
1367mm
1505mm
Utilization=0.3/7.8=0.04 or 4%
57
1505mm
58
4.6.2 Local stress check at the leg of head
The local stress check at head leg for wind load at the stack joint
4.2kN
61.5mm
Shear=0.8kN
Shear force diagram of head
59
4.3kN
NO.2 NO.4
NO.3
Shear=2*0.8=1.6kN
NO.1
NO.5
60
4.7 Sill transom, CR-04 analysis
61
Section properties of Effective section
62
A. Flat outstand with no stress gradient (under uniform compression)
Moment=65,248mm3*160MPa/1.1=9.5kNm
63
B. Unreinforced Flat Internal Element under Uniform Compression
Moment=65,765mm3*160MPa/1.1=9.6kNm
64
C. Unreinforced Flat Outstand Element under Stress Gradient
Moment=65,765mm3*160MPa/1.1=9.6kNm
65
D. Unreinforced Flat Internal Element under Stress Gradient
Moment=65,765mm3*160MPa/1.1=9.6kNm
66
E. Classification of cross-section - Moment Resistance of lateral Torsional Buckling
1505mm
67
G. Load of bending moment and defection
2833mm
1367mm
1505mm
68
4.7.2 Local stress check at the leg of sill
22mm
2kN
2kN
2*0.8=1.6kN
NO.4
NO.1
69
Screw #12(diameter=5.5mm), Stainless steel Grade A2-70
Area= 13.8mm2; Shear strength=311MPa;
Shear capacity (Both sides)=2*311MPa*13.8mm2= 8.5kN > Max. Resultant= 1.5*1.43=2.2kN…OK
70
4.8 Intermediate transom, CR-06 analysis
71
72
A. Unreinforced Flat Internal Element under Uniform Compression
Moment=65,728mm3*10MPa/1.1=6.6kNm
73
B. Unreinforced Flat Internal Element under Stress Gradient
Moment=65,728mm3*10MPa/1.1=6.6kNm
74
C. Unreinforced Flat Outstand Element under Stress Gradient
Moment=65,728mm3*10MPa/1.1=6.6kNm
75
D. Classification of cross-section - Moment Resistance of lateral Torsional Buckling
1505mm
76
F. Analysis of bending moment and defection
1367mm
2833mm
1505mm
1505mm
77
4.8.2 Intermediate transom connection fixing
Horizontal shear=0.8kN
Vertical shear=0.6kN or total load=0.6*2=1.2kN
1.2kN
No.2 No.3
2*0.8=1.6kN
No.1
No.4
78
Screw #12(diameter=5.5mm), Stainless steel Grade A2-70
Area= 13.8mm2; Shear strength=111MPa;
Shear capacity (Both sides)=2*111MPa*13.8mm2=8.5kN > Max. Resultant= 1.5*0.96=1.5kN…OK
79
4.9 Reactions of Curtain wall
Typical bracket
Corner bracket
Dead load=3kN+0.493kN=3.5kN
In plane load=0.3kN
Dead load=3kN+0.5167kN=3.5kN
80
4.10 Bolt M12, fist and hook bracket analysis-Typical bracket
13.2kN
13.2kN
4.8kN
81
4.10.2 Fist bracket, CR-20
92mm
75mm
160mm
Dead load=0.5*4.8kN Wind load=0.5*13.2kN
82
Results of analysis
Factored load:
1.35DL+1.5WL(Negative)
83
4.10.3 Hook bracket, CR-21
84
Notch 50mm
Dead load
=0.5*4.8kN
Wind load
=0.5*13.2kN
85
Results of analysis
Factored Load:
1.35DL+1.5WL(Negative)
86
4.11 Floor bracket and bolt M12 grade A4-70 analysis-typical bracket
Design loads
Factored horizontal load =1.5*8.8=13.2kN
Factored vertical load =1.35*3.5=4.8kN
13.2kN
35mm
4.8kN
13.2kN
0.4kN
Auminium bracket
Limiting bending stress ρo 240 MPa-Grade 6061-T6
Limiting shearing stress ρv 145 MPa
87
4.12 Bottom support analysis
1.2kN
88
4.13 Aluminium corner brackets analysis
7.4kN
35mm
2.4kN
147mm
247mm
7.4kN
89
M10 S/S A4-70
7.4kN
90
From dwg HX-FC-SHD-C1-8423-00-210&303
Fist bracket and hook bracket will not be checked in this submittal.
Hook bracket
Fist bracket
91
4.14 Typical aluminium sunshade bracket analysis
92
Typical Aluminium Sun Shade Brackets analysis
EN 1999-1-1 : 2000 Eurocode 9 : Design of aluminium structures : Part 1-1 : General rules
Aluminium Properties
EN 1991-1-1:2007 Enrocode 9: Design of aluminium structures - Part 1-1 : General structural rules
1. Aluminium Extrusion - Alloy 6063-T6 for Male & female mullion, head and sill
4. Partial Factor
•••• 1 ••• 11
Porperties of Sun Shade Profile
Aluminium profile no.1
2
Aal_p1 := 561.7mm
2
Aal_p2 := 994.9mm
•••• 2 ••• 11
2
Aal_p3 := 1161.1mm
2
Aal_p4 := 514.4mm
•••• 3 ••• 11
Load Case :
Load Case - 1:
Using Point Load on top of the Sun Shade (Lateral Load): LL := 1.5KN
Load Case - 2:
A B
FLL
FDL_P1 FDL_P4
FDL_P2 A
FDL_P3 B
FWL_1 FWL_2
•••• 4 ••• 11
A.) Check Aluminum at Section A-A :
Using 4.5mm Thk. Alumin ium Plate Grade 6061-T6 for End Plate of Sun Shade :
A
FLL
FDL_P1
FDL_P2 A
FWL_1 FWL_2
Design Load :
Increase Total Dead Load by 10% to Include Other Accessories Weight and Misc. Items:
( ) (
Mx.actA_WL := FWL_1a 199mm + FWL_2a 36.5mm ) Mx.actA_WL = 0.109 KN m
•••• 5 ••• 11
Combination Factored Load Case:
( ) (
Mx.actA_1 := 1.35 Mx.actA_DL + 1.4 Mx.actA_LL ) Mx.actA_1 = 0.703 KN m
( ) (
Mx.actA_2 := 1.35 Mx.actA_DL + 1.4 Mx.actA_WL ) Mx.actA_2 = 0.174 KN m
(
Mx.actA := max Mx.actA_1 , Mx.actA_2 )
Mx.actA = 0.703 KN m
Mx.actA = 0.703 KN m
( )
6 Mx.actA
Actual Bending Stress : fbx_A := fbx_A = 183.34 MPa
(ta1) (wa)2
fo_T1
Fb_cap.6061T6 := Fb_cap.6061T6 = 218.18 MPa
Factored Bending Stress Capacity: γm_al
fbx_A fbx_A
Ratio of Actual to Factored = 0.84 < 1.0 = 1 ( OK)
Bending stresses: Fb_cap.6061T6 Fb_cap.6061T6
•••• 6 ••• 11
B.) Check Aluminum at Section B-B :
Using 6.35mm Thk. Alu miniu m Plate Grade 6061-T6 for Aluminium Bracket of Sun Shade :
B
FLL
FDL_P1 FDL_P4
FDL_P2 FDL_P3 B
FWL_1 FWL_2
Design Load :
Dead Load of Profile No.1: FDL_P1 = Aal_p1 La ρalum FDL_P1 = 0.023 KN
Increase Total Dead Load by 10% to Include Other Accessories Weight and Misc. Items:
Mx.actB_DL = 0.051 KN m
•••• 7 ••• 11
Combination Factored Load Case:
( ) (
Mx.actB_1 := 1.35 Mx.actB_DL + 1.4 Mx.actB_LL ) Mx.actB_1 = 1.33 KN m
( ) (
Mx.actB_2 := 1.35 Mx.actB_DL + 1.4 Mx.actB_WL ) Mx.actB_2 = 0.577 KN m
(
Mx.actB := max Mx.actB_1 , Mx.actB_2 )
Mx.actB = 1.33 KN m
(
6 Mx.actB )
Actual Bending Stress : fbx_B := fbx_B = 191.49 MPa
(tb) (wb) 2
fo_T1
Fb_cap.6061T6 = Fb_cap.6061T6 = 218.18 MPa
Factored Bending Stress Capacity: γm_al
fbx_B fbx_B
Ratio of Actual to Factored = 0.878 < 1.0 = 1 ( OK)
Bending stresses: Fb_cap.6061T6 Fb_cap.6061T6
•••• 8 ••• 11
Checked for Bracketa Screw, 5 nos x M6 S/S Grade A4/70
π
Tensile Stress Area: As_6 :=
4
(
d6 - 0.9382P p_m6 )2 (Clause 1.7 AS 1275-1985)
2
As_6 = 20.1 mm
PntA4 := 700MPa
Nominal Tensile Strength of Grade A4/70:
PtbA4 := 450MPa
Design Tensile Strength of Grade A4/70:
(
0.9 PntA4 As_6 )
Factored Tensile Load Capacity: Ptb_cap_bA := Ptb_cap_bA = 12.678 KN
γm_bt
PtbA4 ( As_6)
Factored Shear Load Capacity: Psb_cap_bA := Psb_cap_bA = 9.055 KN
γm_bt
FLL
FDL_P1 FDL_P4
FDL_P2 FDL_P3
•••• 9 ••• 11
Table of Calculate shear forces of each screw
2
Bolt Modulus, Σ(x2+y2), Bmol: BmolA := 6521.25mm
Vact_screw Vact_screw
Ratio of Actual to Factored Shear Load: = 0.899 < 1.0 = 1 ( OK)
Psb_cap_bA Psb_cap_bA
•••• 10 ••• 11
Bearing Capacity Check: (Clause 6.4.4 BS 8118-1991)
pa := fbr_s275
(na ca da ta pa)
Bearing Capacity of connected ply; BRP =
γm_al
Va = 8.141 KN
When: Ratio ; da
ca. := return "2" if < 10
ta
20t a da
return if 10 < < 13
da ta
da
return "1.5" if > 13
ta
:= 2
cVaact_s
(na ca da ta pa)
Bearing Capacity of connected ply; BRP :=
γm_al
BRP = 15 KN
Va
Bearing Load Ratio; = 0.543
BRP
Va
< 1.0 = 1 ( OK)
BRP
Therefore : Using 5 Nos.(5Nos. Each Side of Mullion Bracket) M6x15mm CSK. Machine Screw
Grade A4-70 as detailed above is structurally adequate.
•••• 11 ••• 11
4.15 Aluminium sunshade bracket at corner analysis
93
Porperties of Sun Shade Profile
Aluminium profile no.1
2
Aal_p1 := 561.7mm
2
Aal_p2 := 994.9mm
•••• 1 ••• 10
2
Aal_p3 := 1161.1mm
2
Aal_p4 := 514.4mm
•••• 2 ••• 10
Load Case :
Load Case - 1:
Using Point Load on top of the Sun Shade (Lateral Load): LL := 1.5KN
Load Case - 2:
A B
FLL
FDL_P4
FDL_P1
FDL_P2 A
FDL_P3 B
FWL_1 FWL_2
•••• 3 ••• 10
A.) Check Aluminum at Section A-A :
Using 4.5mm Thk. Alumin ium Plate Grade 6061-T6 for End Plate of Sun Shade :
A
FLL
FDL_P1
FDL_P2 A
FWL_1
Design Load :
Increase Total Dead Load by 10% to Include Other Accessories Weight and Misc. Items:
(
Mx.actA_WL := FWL_1 146.5mm ) Mx.actA_WL = 0.076 KN m
•••• 4 ••• 10
Combination Factored Load Case:
( ) (
Mx.actA_1 := 1.35 Mx.actA_DL + 1.4 Mx.actA_LL ) Mx.actA_1 = 0.699 KN m
( ) (
Mx.actA_2 := 1.35 Mx.actA_DL + 1.4 Mx.actA_WL ) Mx.actA_2 = 0.123 KN m
(
Mx.actA := max Mx.actA_1 , Mx.actA_2 )
Mx.actA = 0.699 KN m
Mx.actA = 0.699 KN m
( )
6 Mx.actA
Actual Bending Stress : fbx_A := fbx_A = 187.47 MPa
(ta1) (wa)2
fo_T1
Fb_cap.6061T6 := Fb_cap.6061T6 = 218.18 MPa
Factored Bending Stress Capacity: γm_al
fbx_A fbx_A
Ratio of Actual to Factored = 0.859 < 1.0 = 1 ( OK)
Bending stresses: Fb_cap.6061T6 Fb_cap.6061T6
•••• 5 ••• 10
B.) Check Aluminum at Section B-B :
Using 9.35mm Thk. Alu miniu m Plate Grade 6061-T6 for Aluminium Bracket of Sun Shade :
B
FLL
FDL_P4
FDL_P1
FDL_P2 FDL_P3 B
FWL_1 FWL_2
Design Load :
Dead Load of Profile No.1: FDL_P1 = Aal_p1 La ρalum FDL_P1 = 0.023 KN
Increase Total Dead Load by 10% to Include Other Accessories Weight and Misc. Items:
Mx.actB_DL = 0.072 KN m
•••• 6 ••• 10
Combination Factored Load Case:
( ) (
Mx.actB_1 := 1.35 Mx.actB_DL + 1.4 Mx.actB_LL ) Mx.actB_1 = 1.88 KN m
( ) (
Mx.actB_2 := 1.35 Mx.actB_DL + 1.4 Mx.actB_WL ) Mx.actB_2 = 0.815 KN m
(
Mx.actB := max Mx.actB_1 , Mx.actB_2 )
Mx.actB = 1.88 KN m
(
6 Mx.actB )
Actual Bending Stress : fbx_B := fbx_B = 183.87 MPa
(tb) (wb) 2
fo_T1
Fb_cap.6061T6 = Fb_cap.6061T6 = 218.18 MPa
Factored Bending Stress Capacity: γm_al
fbx_B fbx_B
Ratio of Actual to Factored = 0.843 < 1.0 = 1 ( OK)
Bending stresses: Fb_cap.6061T6 Fb_cap.6061T6
•••• 7 ••• 10
Checked for Bracketa Screw, 5 nos x M8 S/S Grade A4/70
π
Tensile Stress Area: As_8 :=
4
(
d8 - 0.9382P p_m8 )2 (Clause 1.7 AS 1275-1985)
2
As_8 = 36.6 mm
PntA4 := 700MPa
Nominal Tensile Strength of Grade A4/70:
PtbA4 := 450MPa
Design Tensile Strength of Grade A4/70:
( )
0.9 PntA4 As_8
Factored Tensile Load Capacity: Ptb_cap_bA := Ptb_cap_bA = 23.063 KN
γm_bt
PtbA4 ( As_8)
Factored Shear Load Capacity: Psb_cap_bA := Psb_cap_bA = 16.474 KN
γm_bt
FLL
FDL_P4
FDL_P1
FDL_P2 FDL_P3
•••• 8 ••• 10
Table of Calculate shear forces of each screw
2
Bolt Modulus, Σ(x2+y2), Bmol: BmolA := 6521.25mm
Vact_screw Vact_screw
Ratio of Actual to Factored Shear Load: = 0.699 < 1.0 = 1 ( OK)
Psb_cap_bA Psb_cap_bA
•••• 9 ••• 10
Bearing Capacity Check: (Clause 6.4.4 BS 8118-1991)
pa := fbr_s275
(na ca da ta pa)
Bearing Capacity of connected ply; BRP =
γm_st
Va = 11.516 KN
When: Ratio ; da
ca. := return "2" if < 10
ta
20t a da
return if 10 < < 13
da ta
da
return "1.5" if > 13
ta
:= 2
cVaact_s
(na ca da ta pa)
Bearing Capacity of connected ply; BRP :=
γm_st
BRP = 22.08 KN
Va
Bearing Load Ratio; = 0.522
BRP
Va
< 1.0 = 1 ( OK)
BRP
Therefore : Using 5 Nos.(5Nos. Each Side of Mullion Bracket) M8x15mm CSK. Machine Screw
Grade A4-70 as detailed above is structurally adequate.
•••• 10 ••• 10
APPENDIX A
HX-INH-CAL-C1C2-0002 – wind load analysis (Approved), PAGE AA TO A-12
94
PROPOSED ERECTION OF A NEW 12-STOREY OFFICE BUILDING AND ADDITIONS AND
ALTERATIONS TO EXISTING 8-STOREY OFFICE BUILDING, INVOLVING 2 NOS OF DRAINAGE
RESERVE ON LOT 07099M, 06353P(PT), 05739N (PT) AND 06354T(PT) MK23 AT 20
JALAN AFIFI (GEYLANG PLANNING AREA)
AA
PROJECT TITLE:
Certis Centre Redevelopment
STRUCTURAL CALCULATION
FOR
Wind load
Date: 17-Jan.-2023
Revision: 0
AB
1. DESIGN INFORMATION AND CRITERIA
A 1
Mechanical Properties: Grade 316
Minimum 0.2% proof stress, Y0.2 205MPa
Minimum Ultimate Tensile Strength, Us 510MPa
Mechanical Properties: Grade 316L
Minimum 0.2% proof stress, Y0.2 190MPa
Minimum Ultimate Tensile Strength, Us 490MPa
d. Stainless steel bolts (BS6105)
Structural Stainless Steel Bolts: Bolts Grade A2-A4/50
Ultimate Tensile Strength, Usb 500MPa
Stress at 0.2% permanent Strain, Y0.2b 210MPa
Shear Strength, Psb 145MPa
Bearing Strength, Pbb 511MPa
Tensile Strength, Ptb 240MPa
Structural Stainless Steel Bolts: Bolts Grade A2-A4/70
Ultimate Tensile Strength, Usb 700MPa
Stress at 0.2% permanent Strain, Y0.2b 450MPa
Shear Strength, Psb 311MPa
Bearing Strength, Pbb 828MPa
Tensile Strength, Ptb 374MPa
Structural Steel Bolts: Bolts Grade A2-A4/80
Ultimate Tensile Strength, Usb 800MPa
Stress at 0.2% permanent Strain, Y0.2b 600MPa
Shear Strength, Psb 384MPa
Bearing Strength, Pbb 1008MPa
Tensile Strength, Ptb 464MPa
e. Glass Panels: Strength and Allowable Deflection based on AS1288-2006
f. Structural silicone sealant: 0.138 MPa (under wind load)
A 2
Horizontal UDL line load: 1.5 KN/m
Horizontal UDL Infill load: 1.5 KN/m^2
Horizontal Point load: 1.5 KN
e. Loading combinations
- Structural use of Aluminum
Table 3.1 - Partial factors for loads
Type of load γf1
Dead load 1.35
Imposed load (not including wind load) 1.5
Wind load 1.5
Barrier load 1.6
- Structural use of steelwork in building
Table 2 - Partial factors for loads
Type of load γf1
Dead load, except as follow 1.35
Dead load acting together with wind load and imposed load combined 1.35
Dead load whenever it counteracts the effects of other loads 1.0
Imposed load (not including wind load) 1.5
Imposed load acting together with wind load 1.05
Wind load 1.5
Wind load acting together with imposed load 0.9
A 3
2.Summary for Wind Load
The maximum value of the corner area is used to calculate the wind load
LEVEL AREA SYSTEM WIND LOAD (kpa)
A 4
A 5
A 6
3 WIND LOAD FOR LEVEL 1~LEVEL 4
3.1 WIND LOAD DESIGN FOR "System below Level 4" (EURCODE EN 1991-1-4)
3.1.1 Basic values
System include
:WF02a/WF03a/EWS106/EWS107/EWS108/EWS109
A 7
co(z) =1 ( flat terrain)
( other types of terrain see section 4.3.3 & Annex 4.3)
lv(z) : turbulence intensity § 4.4
lv=kl/[c 0 (z)×ln(z/z )】 (z <z<z )
0 min max
= 0.65 kN/m^2
3.1.4 Design wind load
D=33.2 H=60 H/D=1.8
qw = (Cpe + Cpi) × q(Z)× Cs×Cd
Cs×Cd=1.0
Table7.1-Recommended values of external pressure coefficients for vertical walls of
h/d c pe (10) c pepe(1) c pe (10) c pe (1) c pe (10) c pe (1) c pe (10) c pe (1) c pe (10) c pe (1)
A 8
4 WIND LOAD FOR LEVEL 4~LEVEL 12
4.1 WIND LOAD DESIGN FOR "System Level 4 ~ Level 12" (EURCODE EN 1991-1-4)
4.1.1 Basic values
System include : EWS101/EWS102/EWS101a/EWS101b
A 9
co(z) =1 ( flat terrain)
( other types of terrain see section 4.3.3 & Annex 4.3)
lv(z) : turbulence intensity § 4.4
lv=kl/[c 0 (z)×ln(z/z )】 (z <z<z )
0 min max
= 0.83 kN/m^2
4.1.4 Design wind load
D=33.2 m H=60 m H/D=1.8
qw = (Cpe + Cpi) × q(Z)× Cs×Cd
Cs×Cd=1.0
Table7.1-Recommended values of external pressure coefficients for vertical walls of
h/d c pe (10) c pepe(1) c pe (10) c pe (1) c pe (10) c pe (1) c pe (10) c pe (1) c pe (10) c pe (1)
A 10
5 WIND LOAD FOR LEVEL 12~ROOF
5.1 WIND LOAD DESIGN FOR "System Level 13 ~ Roof" (EURCODE EN 1991-1-4)
5.1.1 Basic values
System include : EWS/104
Fundamental value of the basic wind velocity ;
Vb0 = 20.00 m/s refer to SS EN 1991-1-4,4.2(1)P Note 2
Directional factor: Cdir=1 § 4.2
Seasonal factor Cseason =1
Basic wind velocity : Vb = Cdir × Cseason × vb,0 = 20.00 m/s
5.1.2 Basic velocity pressure § 4.5
qb =1/2×ρ×Vb^2 = 0.24 kN/m^2
ρair = 1.194 kg/m³ (air density)
5.1.3 Peak pressure § 4.5
q (z) =【1+ 7×lv (z)】× qb×cr(z)^2×co(z)^2
where: cr(z) is the roughness factor § 4.1
co(z) is the orography factor
lv(z) turbulence intensity § 4.4
zmin is the minimum height
zmax is to be taken as 200 m
cr (z)= kT×ln(z/z0) (zmin <z<zmax)
cr (z)= cr( zmin ) (z<zmin)
where: z is the height of calculation = 60.00 m
where: z0 is the roughness length = 0.050 m
kT is the terrain factor, depending on the roughness length z 0 calculated using
kT=0.19(z0/z0II)^0.07 = 0.19
z0II(terrain category)= 0.05
cr (z)= kT×ln(z/z0)= 1.35
A 11
co(z) =1 ( flat terrain)
( other types of terrain see section 4.3.3 & Annex 4.3)
lv(z) : turbulence intensity § 4.4
lv=kl/[c0(z)×ln(z/z0)】 (zmin <z<zmax)
lv=lv(zmin) (z<zmin)
kI is the turbulence factor recommended value for kI is 1,0
z =60 m
so: zmin < z < zmax
lv=kl/[c0(z)×ln(z/z0)】 =0.14
q (z) =【1+ 7×l v (z)】× qb×cr(z)^2×co(z)^2
= 0.86 kN/m^2
5.1.4 Design wind load
D=33.2 m H=60 m H/D=1.8
qw = (Cpe + Cpi) × q(Z)× Cs×Cd
Cs×Cd=1.0
Table7.1-Recommended values of external pressure coefficients for vertical walls of
rectangular plan buildings
Zone A B C D E
h/d c pe (10) c pepe(1) c pe (10) c pe (1) c pe (10) c pe (1) c pe (10) c pe (1) c pe (10) c pe (1)
A 12
APPENDIX B-Movement joint engineering analysis
Movement analysis
Movements that were calculated less than the movement capacity of the system
95
Movements that were calculated less than the movement capacity of the system
96