100% found this document useful (4 votes)
3K views2 pages

Scaffolding Calculation

The document summarizes the design of a tower scaffolding structure for an overhead crane. It is 14 meters high, with dimensions of 2m x 2m. It will be constructed from steel pipe with an outer diameter of 48.6mm and wall thickness of 3.2mm, with a yield strength of 240MPa. Loads considered include dead load from the structure itself, live floor load of 2.5kN/m^2, and wind loads of 0.7kN/m^2. Load combinations are listed. Analysis found the maximum utilization ratio of 0.484 to be less than 1, confirming the design is acceptable. Dimensioned drawings and specifications of the scaffolding are provided.

Uploaded by

Reza Furqon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
3K views2 pages

Scaffolding Calculation

The document summarizes the design of a tower scaffolding structure for an overhead crane. It is 14 meters high, with dimensions of 2m x 2m. It will be constructed from steel pipe with an outer diameter of 48.6mm and wall thickness of 3.2mm, with a yield strength of 240MPa. Loads considered include dead load from the structure itself, live floor load of 2.5kN/m^2, and wind loads of 0.7kN/m^2. Load combinations are listed. Analysis found the maximum utilization ratio of 0.484 to be less than 1, confirming the design is acceptable. Dimensioned drawings and specifications of the scaffolding are provided.

Uploaded by

Reza Furqon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

C0307C - Tower Scaffolding for Overhead Crane

Project : C0307C
Works Item : Tower Scaffolding for Overhead Crane
Date : 28th August 2023

Tower Scaffolding for OHC Section Properties


Dimension Value Steel Pipe OD48.6 x 3.2WT
Length 2m Fy 240 MPa
Width 2m
Height 14 m

LOADS AND LOADING COMBINATIONS


LOADS
1. Dead load (DL) Structure of scaffolding using JIS pipe with diameter 48.6 mm and 3.2 mm thick.
Selfweight will be calculated automatically by STAAD Pro software.
2. Live load (LL) Floor live load for scaffolding structure is 2.5 kN/m^2.
3. Wind load (W) Wind loads for scaffolding structure assigned as intensity 0.7 kN/m^2 and
will be calculated automatically by STAAD Pro software.
4. Earthquake load (E) Earthquake loads not considered for temporary tower scaffolding structures
LOAD COMBINATIONS
· LOAD COMB 1 1.4DL
· LOAD COMB 2 1.2DL+1.6LL
· LOAD COMB 3 1.2DL+1.6LL+0.5WX
· LOAD COMB 4 1.2DL+1.6LL+0.5WZ

Dead Load (Selfweight) Live Load Wind Load Structure Analysis

Maximum utilization ratio =


0.484 < 1
Thus, OK.
CONCLUSION

Design of Scaffolding Structure

Isometric View Front View Side View Top View

Specifications :

Steel Pipe OD48.6 x 3.2WT


Fy 240 MPa
Length 2m
Width 2m
Height 14 m
Vertical Stair 75 °

Prepared Checked
RAF CAN