100% found this document useful (5 votes)
5K views2 pages

Cantilever Scaffolding Calculation

The document provides specifications for a cantilever scaffolding structure for an overhead crane. The scaffolding is 3 meters long, 1.5 meters wide, and 2.5 meters high, and is constructed of steel pipe with an outer diameter of 48.6 mm and thickness of 3.2 mm. Load combinations to be considered in the structural analysis include dead load, live load of 1 kN/m^2, and wind loads of 0.7 kN/m^2. The analysis found the maximum utilization ratio of 0.487 to be less than 1, confirming the design is acceptable. Dimensioned drawings and an isometric view of the completed scaffolding design are also included.

Uploaded by

Reza Furqon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (5 votes)
5K views2 pages

Cantilever Scaffolding Calculation

The document provides specifications for a cantilever scaffolding structure for an overhead crane. The scaffolding is 3 meters long, 1.5 meters wide, and 2.5 meters high, and is constructed of steel pipe with an outer diameter of 48.6 mm and thickness of 3.2 mm. Load combinations to be considered in the structural analysis include dead load, live load of 1 kN/m^2, and wind loads of 0.7 kN/m^2. The analysis found the maximum utilization ratio of 0.487 to be less than 1, confirming the design is acceptable. Dimensioned drawings and an isometric view of the completed scaffolding design are also included.

Uploaded by

Reza Furqon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

C0307C - Cantilever Scaffolding for Overhead Crane

Project : C0307C
Works Item : Cantilever Scaffolding for Overhead Crane
Date : 29th August 2023

Cantilever Scaffolding for OHC Section Properties


Dimension Value Steel Pipe OD48.6 x 3.2WT
Length 3m Fy 240 MPa
Width 1.5 m
Height 2.5 m

LOADS AND LOADING COMBINATIONS


LOADS
1. Dead load (DL) Structure of scaffolding using JIS pipe with diameter 48.6 mm and 3.2 mm thick.
Selfweight will be calculated automatically by STAAD Pro software.
2. Live load (LL) Floor live load for scaffolding structure is 1 kN/m^2.
3. Wind load (W) Wind loads for scaffolding structure assigned as intensity 0.7 kN/m^2 and
will be calculated automatically by STAAD Pro software.
4. Earthquake load (E) Earthquake loads not considered for temporary tower scaffolding structures
LOAD COMBINATIONS
· LOAD COMB 1 1.4DL
· LOAD COMB 2 1.2DL+1.6LL
· LOAD COMB 3 1.2DL+1.6LL+0.5WX
· LOAD COMB 4 1.2DL+1.6LL+0.5WZ

Dead Load (Selfweight) Wind Load X Structure Analysis

Live Load Wind Load Z

Maximum utilization ratio =


0.487 < 1
Thus, OK.
CONCLUSION

Design of Scaffolding Structure

Isometric View

Specifications :

Steel Pipe OD48.6 x 3.2WT


Fy 240 MPa
Length 3m
Width 1.5 m
Height 2.5 m

Prepared Checked
RAF CAN