4966A - Kulim Hi-Tech Tower - TSSR - 2021-04-09 - V1.0
4966A - Kulim Hi-Tech Tower - TSSR - 2021-04-09 - V1.0
4966A - Kulim Hi-Tech Tower - TSSR - 2021-04-09 - V1.0
Site Information
Site ID: 4966A
Site Name: Kulim Hi-Tech Tower
Site Owner: DiGi
Coverage area: Outdoor
Address:
Region Northern
Building / Structure Height:(m) 60
Structure Type: Tower
Latitude: 5.406464
Longitude: 100.571678
Access Information
Site Access Business Hours Key Collection Point MSC
BM PIC for Site Access Direct Access Key Type COMMON
Department of BM PIC Direct Access Crane / Skylift needed NO
Contact Number for Site Access Direct Access Size of Crane / Skylift
Work Permit YES Skylift/Crane Parking Space NO
Surveyor Information
Company CCS Technical Site Surveyor SAADAL
Survey Date: 2021-04-01T16:00:00.000Z Contact Number 012-560 1942
SOW Summary
Work Under ZTE
WORK ADD SWAP
Rectifier Module Propose to reused Rectifier Module
Battery Solution Propose to reused Battery
Power DCPD6/DCPD10B Propose to reused DCPD6
System Cabinet Rectifier N/A
Breaker Propose to reused DC Breaker
AC or DC Cables N/A
BBU Cards PROPOSE NEW VEMc1 VFC1 VSWd1 VBPc1 VPDc1
BBU BBU Proposal PROPOSE TO SWAP BBU TO V9200 BBU
Proposal
BBU Cables N/A
RRU Type Propose to swap existing RRU 2600 o new R8854 2600 RRU for sec 123
DC Cables Propose to reused existing 3 x DC Cable for new RRU
RRU Fiber Cables Propose to reused existing 3 x CPRI Cable for new RRU
Proposal Jumper Cables Propose to install new 12 x 5m Jumper Cable for new RRU
Feeder Cables N/A
BiasT Solution N/A
Antenna Antenna Solution Propose to reused existing RV4PX308R-V2 antenna for new RRU for sec 123
Proposal RET(AISG) Cables N/A
Tx Photos Tx Port
uBPG3 BPN2
BBU 1
PM3 VPDc1
PM3 VPDc1
BPN2
SA
SA CCE1B BPK_1 VSWd1 VPDc1
PM3
Existing
FS5 uBPG3
PM3
UES BPN2
SA
SA CCE1B uBPG3
SA
SA
New Proposal
PROPOSE NEW VEMc1 VFC1 VSWd1 VBPc1 VPDc1 PROPOSE TO SWAP BBU TO V9200 BBU
AC
AC
Blue YES New AC breakers Quantity
Existing AC Cables Size 100A AC Breakers
Main Input Breaker Capacity 100A
RECTIFIER
No. Rectifier Module 6 Required New Rectifier Moudle
No. of Rectifier Slot Available 0 New Rectifier Moudle Quantity
Output Voltage 53.1V Grounding Cable Length
Current Load 185.9A
CSU Display YES
DCPD Type Unit No of Port Available Existing Breaker DCPD Solution Reuse
DCPD 6 1 6 125A DCPD Type DCPD6
DCPD 10B 1 6 100A DCPD Breaker Solution
DCPD
DCPD
New Proposal
100A Breaker
No. Required New DC breakers
Existing
125A Breaker
DCPD Cable Length
Grounding Cable Length
Battery
Site/Room/Cabin Overview
Site/Room/Cabin Overview
4.5 Overall Cable Routing
Cable Routing 2
Sector 1
RF Info RRU 1 RRU 2 RRU 3 RRU 4 RRU 5 RRU 6 RRU 7 RRU 8 RRU 9
Bi Sector
RET Model
TMA
Combiner Type
Feeder Type
Jumper & Feeder
Cascade
RRU Cables
Sector 1
RF Info RRU 1 RRU 2 RRU 3 RRU 4 RRU 5 RRU 6 RRU 7 RRU 8 RRU 9
RET Model
TMA
Combiner Type
Bias Tee
Cascade
RRU Cables
Existing Combiner
Proposal Sec 1 RRU Remark Propose to swap existing RRU 2600 o new R8854 2600 RRU for sec 123
Sector 1 Antenna Proposal
New Proposal
Propose to reused existing RV4PX308R-V2 antenna for new RRU for sec 123
Sector 1 New Panaromic Proposal
New Proposal
Bi Sector
RET Model
TMA
Combiner Type
Feeder Type
Cascade
RRU Cables
Sector 2
RF Info RRU 1 RRU 2 RRU 3 RRU 4 RRU 5 RRU 6 RRU 7 RRU 8 RRU 9
RET Model
TMA
Combiner Type
Bias Tee
Cascade
RRU Cables
Existing Combiner
Propose to reused existing RV4PX308R-V2 antenna for new RRU for sec 123
Sector 2 New Panaromic Proposal
New Proposal
Bi Sector
RET Model
TMA
Combiner Type
Feeder Type
Jumper & Feeder
Cascade
RRU Cables
Sector 3
RF Info RRU 1 RRU 2 RRU 3 RRU 4 RRU 5 RRU 6 RRU 7 RRU 8 RRU 9
RET Model
TMA
Combiner Type
Bias Tee
Cascade
RRU Cables
Existing Combiner
Propose to reused existing RV4PX308R-V2 antenna for new RRU for sec 123
Sector 3 New Panaromic Proposal
New Proposal
Panoramic View : 0°
Panoramic View : 30 °
Panoramic View : 60°