g5.rss Product Description
g5.rss Product Description
Accuracy
The G5.RSS series has an exceptional accuracy of
Options
<0.02% FS. There is even an additional high-resolution Software and Control
current measurement range from -10 to 10% FS.
Time-Based Function Generator
The TFE time-based function generator allows
programming either through G5.Control operating
software, HMI touch display, or CANmp interface.
Time-dependent functions U = f(t), I = f(t), proprietary CAN bus. In addition, it supports dbc file
P = f(t): sine, triangle, or square as well as handling.
user-defined data points. Import and export
User Safety
through csv files supported
Sweep function for current ripple modulation Integrated safety relay (ISR) for increased
0…10 kHz emergency stop reliability supporting
performance level PL c / PL e according to
Application Area Programming EN ISO 13849
The AAP application area programming feature allows Discharge of AC filter (XCD), recommended
to set the DC output voltage or current or power as a for mobile use of the device. XCD ensures a
function of any of the input values IDC, UDC, or PDC. The discharge time of the AC filter <1 s as
functional relationship is given by a user-defined curve required by EN 62477-1
whose values are managed by CSV import/export. In AC terminal protection cover (PAC.AC),
this way, a wide variety of nonlinear electrical two-
recommended for use as tabletop unit
pole networks can be defined, e.g., photovoltaic
arrays or fuel cell curves. As an example, Figure 3
Rack-Integrated System Solutions
shows the typical fuel cell characteristics with a
voltage/current dependence. Embedded calculation Mobile rack solutions up to IP54
on board the G5.RSS assures real-time simulation. Insulation monitoring: remote activation of the
insulation measurement, actual insulation value
and warning/error status are provided by
CANmp interface or by optional HMI
Easy reconfiguration between parallel, series,
and mixed operation
HMI
The HMI built into the front panel allows compre-
hensive and convenient operation of the power
supply via touch display.
Environmental Conditions
Intuitive control by HMI touch display. Everything you need at
Front-panel-mounted air filter (AirFilter), recom-
a glance. mended for use in dusty environments.
CAN Interface
The CAN multi-protocol (CANmp) interface has a 1 kHz
data rate, a 16-bit resolution and is adaptable to any
System Capability
Modular and easy scalable systems
Parallel, series, and mixed operation with a
digital high-speed bus
Simple master-slave configuration with the
operating software
Easy rack mounting
Optional safety features such as 2-channel
safety interface and insulation monitoring
For detailed technical information, contact your local sales
Turn-key cabinet solutions or project-specific partner or REGATRON.
9400 Rorschach
system integration according to customer SWITZERLAND
Regatron AG Regatron Inc.
specification Feldmühlestrasse 50 100 Overlook Center, 2nd Floor
[email protected]
9400 Rorschach
www.regatron.com Princeton, NJ 08540
SWITZERLAND USA
[email protected] [email protected]
www.regatron.com www.us.regatron.com
NEW