0% found this document useful (0 votes)
48 views2 pages

878 Spec

1. The document provides specifications for supplying and installing concealed/surface mounting boxes, door bells, miniature circuit breakers (MCBs), and MCB distribution boards. 2. It specifies requirements such as the materials, ratings, markings, and configurations for the boxes, bells, MCBs, and distribution boards to ensure safety, durability and compliance with relevant standards. 3. Detailed requirements are given for wiring, fixing, terminals and other components to provide a properly installed and functioning electrical system.

Uploaded by

rdeepak99
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

878 Spec

1. The document provides specifications for supplying and installing concealed/surface mounting boxes, door bells, miniature circuit breakers (MCBs), and MCB distribution boards. 2. It specifies requirements such as the materials, ratings, markings, and configurations for the boxes, bells, MCBs, and distribution boards to ensure safety, durability and compliance with relevant standards. 3. Detailed requirements are given for wiring, fixing, terminals and other components to provide a properly installed and functioning electrical system.

Uploaded by

rdeepak99
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EL-81-736-WA-81

Indian Railways Standard General Conditions of Contract, November 2018 66

VIII Supply and fixing No. 1. Box shall be of 16 modules & concealed mounting type of
concealed/surfac Galvanized sheet metal as per Roma model of Anchor make
e mounting box Cat No. 21736 or surface mounted type PVC unbreakable
with Tresa made with high impact plastic as per Roma model of
modular plate for Anchor make Cat No. 34567.
Sixteen number 2. Box plate with base frame in white glossy colour as per
modules. Roma model of Anchor make Tresa 16 module Cat No.
34680 or equivalent of approved make & ISI mark.
3. The board shall be fixed with suitable size & no. of GI
screws.
IX Supply, fixing, No. 1. The bell shall be suitable to work on 230 volt single phase
testing and AC supply.
commissioning of 2. The bell shall be as per Anchor’s cat. No.10489 or
Door Bell Ding equivalent ISI marked of reputed make.
dong type. 3. Supply shall be taken from the nearest available ceiling
rose.
4. The bell shall be connected with the supply point using
zero halogen flame retardant (ZHFR) PVC insulated &
sheathed multi strand three core copper conductor of
adequate size and capacity conforming to IS-694 of 2010
or latest and ISI marked, with proper workmanship.
X Supply, fixing & No. 1. The MCB shall be Double pole neutral isolated type of upto
commissioning of 40A capacity as per site requirement, confirming to
DP MCB of upto IS:8828/1996.
40A capacity as 2. MCBs shall be ISI/CE marked as per IS/IEC 60898-1, C
per site Curve, Rated short circuit breaking capacity Icn- 10KA, IP
requirement, in 20 protected terminals.
enclosure made of 3. The enclosure box shall be of thermoplastic polycarbonate
polycarbonate material with internally embedded polyurethane gasket,
thermoplastic confirming to IEC 60439-1,3.
material with 4. The box shall be weatherproof with IP 65 min., Impact
polyurethane strength IK08 min., self-extinguishing class II insulating
gasket, IP 65 material, fire/flame retardant, environment friendly,
weatherproof. nontoxic & safe.
5. The enclosure box shall be including neutral & earth
terminals, premolded knockouts & cable glands at top &
bottom, DIN rail, blanking strips for unused openings,
with transparent or opaque doors lockable type. Screws
used shall be made of stainless steel.
6. The box shall be compact in design and suitable for single
phase supply system.
7. The box shall be internally wired with copper crimping
socket of suitable size and rating.
8. MCB box shall be fixed on the wall / piller using proper
size and Nos. of screws.
9. The successful tenderer should submit delivery challan /
copy of original voucher of OEM / Authorized dealer to
EL-81-736-WA-81

Indian Railways Standard General Conditions of Contract, November 2018 67

ascertain originality of items like MCBs & enclosure boxes


etc.
10. Catalog no. & specification details of each type /
capacity of MCB, & enclosure box also to be submitted by
the firm.
XI Supply, fixing & No. 1. The MCB distribution board shall be of thermoplastic
commissioning of polycarbonate material with internally embedded
MCB DB single polyurethane gasket, confirming to IEC 60439-1,3.
phase with 2. The board shall be weatherproof with IP 65 min., Impact
RCBO, I/C-DP strength IK08 min., self-extinguishing class II insulating
RCBO of 40Amp – material, fire/flame retardant, environment friendly,
1No and ELCB of nontoxic & safe.
25A capacity, 3. The board shall be including neutral & earth terminals,
O/G: SP MCB of premolded knockouts & cable glands at top & bottom, DIN
6A-32A – 8Nos, of rail, blanking strips for unused openings, with
capacity as per transparent or opaque doors lockable type. Screws used
site requirement, shall be made of stainless steel.
enclosure made of 4. The board shall be suitable for single phase supply
polycarbonate system.
thermoplastic 5. The board shall have the following arrangement. All MCBs
material with shall be as per given Cat. Nos or equivalent make as per
polyurethane enclosed make list.
gasket, IP 65 6. MCBs shall be ISI/CE marked as per IS/IEC 60898-1, C
weatherproof. Curve, Rated short circuit breaking capacity- 10KA, IP 20
protected terminals.
7. RCBOs shall be ISI/CE marked as per IS/IEC 12640-1/2,
Rated sensitivity - 30mA, Rated short circuit breaking
capacity- 10KA, IP 20 protected terminals. It shall conform
to both the residual current device standard IEC 61008
and to switch standards IEC 60947-1 and IEC 60947-3.
Incoming
Double pole RCBO of 40Amp – 1 No as per L & T Exora’s
cat.No.AUF3C204003 or Legrand Cat no. 411327.
Outgoing: Single pole MCB of 6-32 Amp – 08 Nos. (2 Nos.
each of 6A, 10A, 16A and 25A MCBs or as per site
requirement) as per Legrand Cat No. 408587/90/92/94
or L&T Exora’s Cat No.
BB10060C/BB10160C/BB10250C & BB10320C
Busbar: The busbars shall be of copper strips of suitable size
and rating for phase and neutral connections.
8. The board shall be internally wired with copper crimping
socket of suitable size and rating.
9. The board shall be internally wired with FRLS PVC
insulated & sheathed multi strand copper conductor of
adequate size and capacity conforming to IS-694 of 2010
or latest and ISI marked.
10. MCB box shall be fixed on the wall / piller using proper
size and Nos. of screws.

You might also like