01. Fail-safe device must be installed when using the unit with machinery that may
cause serious injury or substantial economic loss.(e.g. nuclear power control,
medical equipment, ships, vehicles, railways, aircraft, combustion apparatus,
safety equipment, crime/disaster prevention devices, etc.)
KT-502H Series
Do not use near the equipment which generates strong magnetic force or high frequency
noise.
• Install a power switch or circuit breaker in the easily accessible place for supplying or
PRODUCT MANUAL
disconnecting the power.
• The explosion-proof standard of this unit is Ex d IIC T6, protection structure of this unit is IP 67
and the range of max. surface temperature is below 85 ℃.
Use the verified explosion-proof electric connection (cable gland or sealing fitting)
For your safety, read and follow the considerations written in the instruction • This unit may be used in the following environments.
manual, other manuals and Autonics website. - Indoors (in the environment condition rated in ‘Specifications’)
The specifications, dimensions, etc. are subject to change without notice for product - Altitude max. 2,000 m
improvement. Some models may be discontinued without notice. - Pollution degree 2
- Installation Category II
• The explosion-proof unit is certified and the same specifications which is reported
to Korea Gas Safety Corporation. (This unit is manufactured following by the
• HART protocol
• 330 ° rotatable display for environment conditions
• Increased visibility with backlight function
• Multi-input (order 1 input type among 22 types)
- RTD 8 types
- Thermocouple 8 types
- mV 4 types
- Resistor 2 types
• Explosion class: Ex d IIC T6
• Protection structure: IP67 (IEC standard)
ᜢᜫ
-|Transparent Guide|-
KT - 502H ❶ - ❷
❶ Mounting bracket ❷ Temperature input range
86
96
0: Without bracket Refer to 'Input Specifications'.
1: With bracket 2- (1/2 14NPT)
□ 55
■ With bracket
Specifications 83 215
142
Model KT-502H
Power supply 10.5 - 45 VDCᜡ (with backlight LCD)
Output DC 4-20 mA (2-wire)
Input specifications Refer to 'Input Specifications'
86
96
Accuracy ± 0.3 %
PV display part: 7 segment 5 digit (character size: W4×H8 mm), 2- (1/2 14NPT)
Display method Parameter display part: 14 segment 8 digit
200
(character size: W2.6×H4.8 mm), 52 bar meter
Display range -19,999 to 99,999
(2B Pipe)
DN50
Setting method HART-protocol (no setting key)
Response time 1 sec
Alarm ≤ 3.8 mA, > 20.5 mA / Sensor break 3.6 mA Mounting bracket
Load ≤ (V power supply - 7.5 V) / 0.22 A 94
Galvanic insulation 2 kVACᜠ (Input/Output)
Unit weight
≈ 1.2 kg (≈ 1.4 kg)
(Packaged) Connections
Ambient temp. -20 to 70 ℃, storage: 20 to 80 ℃ (no freezing or condensation) Indicator
Recorder
Ambient humi. 0 to 85 %RH, storage: 0 to 85 %RH (no freezing or condensation) DCS
Controller
Protection structure IP67 (IEC standard)
HART Communicator
Power
Material Body: Aluminum (AlDc.8S), Cover O-Ring: Buna N Supply
Explosion class 01)
Ex d IIC T6 Min. 250 Ω
Approval ᜢᜫ
1 2 3 4 5 6
01) The explosion class specification is acquired and managed by KONICS.
Input Specifications A B b
RTD
- +
Input type Input range (℃) Input range (℉) mV Power supply
+ - 10.5-45 VDCᜡ
K (NiCr-Ni) -270 to 1,372 -454 to 2,501.6
TC
J (Fe-CuNi) -210 to 1,200 -346 to 2,192 + -
Opening the Cover 1. PV LRV 0.000 deg C ⑥ When the set temperature range is correct, press
2. URV 100.000 deg C (F2) key.
HELP SEND HOME
ABORT O K A A S S A A S S A A S S A A S S
B T B B T T B T B T
⑤ Press (F4) key.
B T B T B T
Connect reference
meter C C U U C C U U C C U U C C U U
ABORT O K D D V V D D V V D D V V D D V V
E W E W E W E W
⑥ Press (F4) key.
E W
Setting fid dev
E W E W E W
output to 4mA F F X X F F X X F F X X F F X X
ABORT O K G G Y Y G G Y Y G G Y Y G G Y Y
Enter meter Value ⑦ Press (F4) key to set 4 mA display value. H H Z Z H H Z Z H H Z Z H H Z Z
4.000
HELP DEL ABORT ENTER
Fid dev output 4.000 ⑧ If output display value is correct, select '1. Yes' and
mA equal to reference press (F4) key. If not, select '2. No' and press
meter ?
1. Yes (F4) key and re-set the display value.
E.g.) If output display value is 3.89mA, select 3.89 and press
2. No ABORT ENTER
(F4) key.
Setting fid dev. ⑨ Press (F4) key.
output to 20mA
ABORT O K
Fid dev output 20.000 ⑪ If output display value is correct, select '1. Yes' and
mA equal to reference press (F4) key. If not, select '2. No' and press
meter ?
1. Yes (F4) key and re-set the display value.
2. No ABORT ENTER
Error
Display Error Troubleshooting
Temperature sensor A, B or all sensors are
ERR05
disconnected Check the temperature
sensor
ERR06 Temperature sensor B is disconnected
When PV is lower than the low-limit value of Check the low-limit value of
set temperature range the set temp. range
ERR07
When PV is higher than the high-limit value of Check the high-limit value
set temperature range of the set temp. range
ERR08