Sensor Dew Point
Sensor Dew Point
com
General
Sensor DRYCAP® 180M
Optimal sensor for refrigeration dryers DRYCAP® 180S
Operating voltage 18 - 35 VDC, 20 - 28 VAC
Power consumption at 24 VDC max. 220 mA
External load for analog output max. 500 Ω
Optional connection cable with
DMT242 connector 2 m or 10 m
DEW POINT ACCURACY VS. MEASUREMENT CONDITIONS
Connector for supply voltage and
Response time 63 % [90 %] at +20 °C gas temperature
signal output
Flow rate >1 l/min and 1 bar pressure
max. wire size 0.75 mm2
-60 -> -20 °C Td (-76 -> -4 °F Td) 5 s [10 s]
max. cable diameter 6.5 mm /PG7
-20 -> -60 °C Td (-4 -> -76 °F Td) 45 s [10 min]
Service cable for serial interface
Accuracy with DRYCAP® 180S ±2 °C (±3.6 °F)
RS232 product code DMT242RS
(see graph below)
70 (AISI 316L)
60
50
Sensor protection stainless steel
e
tion lin sintered filter (HM47280)
40 satura
30 vapor
20
Water Mechanical connection G½” ISO228-1 thread with
10 bonded seal ring (U-seal)
0 Td
y < ± 2°C
Accurac
-10 Electronics housing material plastic (ABS/PC)
-20
-30 Housing classification IP65 (NEMA4)
-40 Weight 225 g
er limit
-50 ur ement range low
-60 Dew point meas Storage temperature range -40 ... +70 °C, (-40 ... +158 °F)
-70
-80 Complies with the EMC standard EN61326-1, Electrical equipment
0 10 20 30 40 50 60 for measurement, control and laboratory use - EMC requirements;
Process temperature (°C) Industrial environment.