0% found this document useful (0 votes)
565 views4 pages

Benway SMS Commands-5

Uploaded by

Arslan Ayub
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
565 views4 pages

Benway SMS Commands-5

Uploaded by

Arslan Ayub
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

序号 功能 (Features) 短信内容(Message content) 回复内容(Replies) 备注(Remarks:)

Remarks: defaulted factory password is 6666;Our IP:114.119.5.230 port:7700


1 Add Administrator No 1 #6666#AAD#1# Cell No# ADD admin account 1 ok!
For example:#6666#AAD#1#13554809219#
2 Add Administrator No 2 #6666#AAD#2#Cell No# ADD admin account 2 ok!
3 Delete Administrator No 1 #6666#DAD#1# Delete admin account 1 OK! For example: #6666#DAD#1# Delete
Adminstrator No1 #6666#DAD#2# Delete
Delete Administrator No2 #6666#DAD#2# Delete admin account 2 OK! Admistrator No2
4
6 For example:#6666#CP#1234#,Password is
Setting password #6666#CP# New password# change password ok!
7 1234
For example:#6666#RP# Recovering
Recovering Password #6666#RP# reset password OK!
password to fty standard
For example:#6666#GL#,Will get the current
Getting Location of longitude and latitude #6666#GL# google map link Location of longitude & latitude and speed of
the vehicle.
8
For example:#6666#GA#,Will get the current
Getting Address #6666#GA# google map link
9 address link of the vehicle。
For example:
Setting IP address of server #6666#IP#IP ADDRESS#Port# #6666#IP#211.154.148.162#7000#OK! #6666#IP#211.154.148.162#7000# ,Setting
10 server IP and port.
For example:
Setting website domin of server #6666#WZ#Domin name#Port# #6666#WZ#WWW.XXX.XXX#7000#OK! #6666#WZ#WWW.szbenway.com#7000#,
11 Setting website domin and Port.
12 Checking IP address #6666#IP?# The IP is: 211.154.148.162:7000 For example:#6666#IP?#

13 Checking IP address after analyzing domin #6666#WZ?# The IP(WZ) is: 211.154.148.162:7000 For example:#6666#WZ?#
14 For example:#6666#SST#3#,Here the unit
Setting time distance in steady status #6666#SST#minutes# #0755#sst#3#ok!
15 is minutes
For example:#6666#SMT#10#,Here the unit
Setting time distance in moving status #6666#SMT#seconds# Set movement upload time,OK!
is senconds 10 to 200s
For example:#6666#CF# ,Cut engine。Only
#6666#CF# Start to cut fule,When speed < 20 ,OK !
16 apply for adminstrator.
Cut engine Fuel cut has already been
17 completed,OK!
Cut engine
Speeding now is > 20, So don't Cut
18 Fuel, Pls wait till speed is<20 and try
again !
For example:#6666#OF# ,Start
#6666#OF# Start to open fuel, OK!
19 engine。Only apply for adminstrator.
Restore engine
Open fuel has already been
20 completed,OK!
39 Set speed of engine cut #0613#SCES#speed# speed range can set from 20 - 250

For example:#6666##COSA#, Cancel over


Cancel over speed alarm #6666#COSA# Close over Speed Alarm, OK!
22 speed alarm
For example:#6666#SSA#1#,Here Levels,
Setting vibration alarm #6666#SSA#Levels# Set alarm level, OK! 1: most fexible 2: standard level 3. lowest level
23
For example:#6666#CSA#,Cancel vibration
24 Cancel vibration arlarm #6666#CSA# Close vibration Alarm, OK!
alarm
Setting phone call monitoring: Device auto
Active Cell Phone Monitoring for monitoring pick up the call after 3 seconds calling from
#Password#OM# Open Monitor, OK!
version(Must have Caller ID function) admin no, and active voice monitoring
25 remotely.
Close phone call monitoring: Device will not
Close Cell Phone Monitoring for monitoring
#Password#CM# Close Monitor, OK! pick up the call from admin no and will hang
version(Must have Caller ID function)
26 up call after 2 seconds.
When there is no caller id function of the
Device call admin no automatically for simcard,can send this sms to the device to
monitoring initially(No need caller id)-- #Password#CALLADMIN# fulfill monitoring. Device will call admin no after
Monitoring 5 seconds of receving this sms, and admin
27 can pick up the call for voice monitoring.
For example:#6666#RESET#,,Device will be
Re-start device #Password#Reset# Start Reset System, OK!
28 re-started in 8-18senconds. No message reply
Recover to factory standard without IP
#Password#Factory# resume factory parameter,OK! No message reply sometimes as it can re-started。
29 address

30 View Model No & IMEI NO #Password#VINFO# View Information view IMEI and software version
Change IMEI NO(15 digital letters) #Password#benway02#New Make sure the IMEI NO combined
31 IMEI No# with 15 digital numbers
32 change language #6666#language#2# 1:Chinese 2:English
#6666#GPRS#0#
33 Open or Close GPRS Data #6666#gprs#1# 0:close GPRS 1:open GPRS
For most of the countries in the world, we had
if no user name and arleady setted APN inside the device, for
#6666#sapn#APN name#user
APN setting password,commands will small part of simcard which couldnt connect to
name#password###
be:#6666#sapn#internet##### platform, please set the APN according to this
34 command.
#6666#SMSA#1# 1= allow sms alarm
35 SMS Alarm
#6666#SMSA#0# 0=Disable sms alarm
#6666#CALLA#1# 1= allow call alarm
36 Call Alarm
#6666#CALLA#0# 0=Disable call alarm
infence=set alert for geo fence in, X range 5-
Set GEO-FENCE Alert #6666#infence#X#
99999 meters
37
outfence=set alert for geo fence out, X range
#6666#outfence#X#
5 to 99999 meters
#6666#ACCAM#0# Close ACC alert
#6666#ACCAM#1# ACC on alert
38 ACC SMS alert settings
#6666#ACCAM#2# ACC off alert
#6666#ACCAM#3# ACC on or off, both status will send alert
39 Set speed of engine cut #0613#SCES#speed# speed range can set from 20 - 250

You might also like