FAP Sccaroso __secr.o3 ["is[”” | [03.02.00 COMBUSTION MONITORING (Cont.) Fuel Nozzle. 1, Plugged Fuel Nozzle (Liquid or Gas) 2. Unscrewed Fuel Nozzle 3. Fuel Nozzle Erosion Atonizing Air System 1. Break in Atomizing Air Line 2. Fault Purge System 3. Atomizing Air Compressor Failure 4. Plugged Atomizing Air Passage at Manifold or Nozzle Pressure Vessel Integrity 1. Cracked Conbustor Casing 2. Damaged Crossfire Tube Piping 3. Cracked or Blown Sight Port 4. Leakage at Flame Detector or Spark Plug First Stage Nozzle (if applicable) 1. Burned out First Stage Nozzle 2. Plugged First Stage Nozzle 103.02.02 COMBUSTION MONITOR TEMPERATURE SPREAD This algorithm uses the max CTDA, and the systen exhaust temperature TTK¥, to calculate allowable spread, TTASPL = (0.145 TTXC-0.08¥CTDA + 30) deg. f. TTXSPL is a median selected value between 30 deg.f MIN and 125 deg.f MAX The three highest spreads (TTXSP1,2,and 3) are calculated and conpared to allowables (constants TTKSP1.2.3 & 4). Logic Signals L60SP1,2. or 4 in , are satisfied if the highest three spreads are greater than their alloxables. Two adjacency checks are also Inade to determine if the lowest and second lowest (L60S°5) are adjacent, and/or if the second lowest and third lowest (L60SP6) are adjacent. With L2SHP1 and 2, monitor spreads can be observed with the monitor enabled but before alarms are enabled The allowable spread is increased by an appropriate bias at startup, fuel transfer, load setpoint raise/lower and at high rate of FSR changes, as enabled by L83SPMB. If there is Jone communication failure, only spread one, TIXSP1 is checked. This is the highest minus the lowest valid thermocouple. © ce Power Generation 36847060 SECT. 03 2000-07-06 se DOCUMENT SERVICES 2000-07-06 ]*“* NONE PAP Ssea7os0 _secr.os}6[ _] [03.02.02 COMBUSTION MONITOR TEMPERATURE SPREAD (Cont) In the combustion monitor function s (allow): = the "allowable spread", based on the average exhaust ‘temperature and compressor discharge temperature the allowable spread must be between the limits TIKSPLT and TTKSPLG in degrees f. (usually about 30 deg.f and 125 deg.f.) TTxSP1 (s1) = the difference between the highest and the lowest thermocouple reading. (spreadl) TTXSP2 (52) = the difference between the highest and the second Jowest thermocouple reading. (spread2) TTHSP3. (53) = the difference between the highest and the third lowest thermocouple reading. (spread3) ‘Signal Valle Units Scale Definition TTKsPI 4.00000 NTO CNTOS COMB MONITOR SPREAD SCALING TTKse2 5.00000 CNTO3_CNTO3__ COMB MONITOR SPREAD SCALING THKSP3 0.80000 CNTO3_CNT03__COMBUSTION MONITOR - SCALING FOR SPREAD TTKsPa ‘100000 ——-ENTU3ENTO3CCOMBUSTION MONITOR - SCALING FOR SPREAD TTKSPL 725000 degF TC. COMB MONITOR CTD LIMIT MAX CONSTANT TIKSPL2 400.000 dog TC_COMBMONITOR CTD LIMIT MIN CONSTANT TTKSPL3 (0.060000 CNTOO_CNTO0 COMB MONITOR CTD LIMIT GAIN CONSTANT TTKSPLA 0.145000 CNTOOCNTOO COMB MONITOR TX GAIN CONSTANT TTKSPLS 60000 degFTODIF COMB MON. CTD LIMITED EX. TEMP OFFSET TTKSPL 570.000 deg © TCDIF COMB MONITOR SPREAD REGION MAXIMUM. TTKSPL7 50000 degF-TCDIF_ COMB MONITOR SPREAD REGION MINIMUM TTKseLe "00000 dag TCDIF COMB MONITOR ALLOWABLE SPREAD BIAS TTKSPLS 30000 _see_—_SECB4 COMB MON. ALLOWABLE SPREAD BIAS PROP GAIN, 103.02,06 COMBUSTION MONITOR SEQUENCE, Monitor trip is enabled when the monitor is enabled at operating speed, 14HS master protection is not tripped U4 NORMAL shutdown is not selected L948 L30seTa, if any thermocouple signal causes the largest spread to exceed the constant TTKSP2, (usually 5 times the allowable spread) for time K30SPTA, an "Exhaust TC Trouble" alarm will annunciate La0sPa if a thermocouple value causes the largest spread to exceed constant TTKSP1, for time K30SPA, a "Combustion Trouble" alarm will annunciate: 368A7060 GE Power Generation A e=" C.P.Swiecicki 2000-07-06 = DOCUMENT SERVICES 2000-07-06 [""* NONE SECT. 03 a5 PPAP™ seearoso __sect.os 7] [03.02.08 COMBUSTION MONITOR SEQUENCE (Cont,) L30sPT a high exhaust tenperature spread trip can occur if 1). Spread 1 exceeds allowable, spread 2 exceeds TTKSP3 times the allowable, and they are adjacent. or, (2). Spread 1 exceeds TIKSP2 tines the allowable, (5 times alloaable = bad thermocouple) and spread 2 exceeds allowable times TTKSP3,and spread 2 and spread 3 are adjacent. or, (3). Spread 3 exceeds allowable times TTKSP4 (which implies that spread 1 and 2 also exceed the allowable times TTKSP4) if (1), (2), or (3) exists for time K30SPT, the turbine will trip Unrough the master protective "4" circuit ‘Value Units Seale Definition 2.000 see SEGS¢ REENABLE TIME DELAY {scons tec._-—=«SECS4__BIASREMOVAL TME DELAY. 11000 SECS¢ COMB TROUBLE ALARI TIME DELAY 2.000 SEOs TRIP TIME DELAY KaosPTa ‘4000 SECS TC TROUBLE ALARM TIME DELAY. keosPaz 2.00000 MINS! SPREAD 3 TRIP TIME DELAY kesseM 0.000. SECS4 MONITOR ENABLE TIME DELAY 03.03.02 WHEELSPACE OVERTEMPERATURE ALARMS There are two dual element thermocouples (TC) in each measurement location to wonitor the wheel space temperatures. The average Lemperature measured by the two IC's is computed and lcompared to an alarm level for each location. If this average temperature exceeds the Jalarm level, a conmon alarm, L30WSA2, is generated. For the first hour of operation. WSKALM9 is added to each of the alarm levels. The two TC's at each location are also compared against each other. If they differ by Inore than WSKALMB, an alarm L3ONSAL is given, All of the average wheel space temperature values are compared against each other and the highest value Is selected. This value is ‘then compared to LK69THW, Lo allow water ash. ® cE Power Generation A SECT. 03 C.P.Swiecicki 2000-07-06 f° DOCUMENT SERVICES 2000-07-06 [*“* NONE Inputs Name [Data Type [Description P2 Real Downstream gas pressure Pi Real Upstream gas pressure KGINOM Real Nominal upstream gas pressure FNVPOS Real Fuel metering valve HINITX Unsigned Double DX index from last lookup in high table Integer HINITY Unsigned Double FY index from ast lookup in high table Integer HTABLSDLT Bitable_F Bivariant LOB high pressure correction table name TINTX Unsigned Double DX index from last lookup in low table Integer UNITY Unsigned Double FY index from ast lookup in low table Integer TIABLSOII Bitable Bivariant LOB low pressure correction table name Outputs Name [Data Type Description PRATIO Real PAIP2 pressure ratio PDELTA Real Dalta pressure (P1-P2) AREA_OR Real Fuel metering valve area correction (in'2) |AREACRH Real Fuel metering valve area hi pressure correction (im"2) AREACRE Real Fuel metering valve area low pressure correction (in'2) 65 Combustion Spread Monitor (TTXSPV4) Block Category: TTXSPV4, Gas Turbine This block is typically used on MS7001 and MS9001 turbines ‘The Combustion Spread Monitor (TTXSPV4) block takes the sorted thermocouples and runs the exhaust temperature spread monitor for redundant temperature ser Instruction Guide GE Internal GEI-100680R 115 R TSP R ycroat cro | Bl croa2: R “yest ode at dam tn ® me LieTo, Exsev R Eksp R br Exseus R Ehxspus Ekseus KsPU7 txsreo———4 *{.s:see ——J R ixseis si 4 R EyxspLe a Mtt¥Be) TTXSPL 8 t Lessee a Bus om R FTTXD2L—| eaeuste | ca arxset Ee k spreads |_O-(e) TaxsP2 ikon R TrxsP3 }— Txsat 8 KsPt Lsose1 -— e Kse2 usose2 -— 2 KsP3 usoses F> e Kses usoses F= Lassen : cency check a ABOARD. = XD et e ‘esl or). usoses -— 9 dacencs check * adacencs BOLD et) -XD- 2) maid uate 2 Ty 22H rerorre Gagareypet | sir iz0) TIXSPV4 Block 116 GEI-100680R GE Internal ‘Mark Vie Controller Turbine Block Library Inputs Name Data type Description [CTOAT Real ‘Compressor discharge TO 1 [eTOAz Real ‘Compressor discharge TO 2 KSPLI Real Maximum CTDA constant KSPL2 Real ‘Minimum CTDA constant KSPL3 Real (CTD gain constant TixM Real ‘Average exhaust temperature KSLA Real TX gain constant KSPLS Rear Tk offset constant KSPLE Real ‘Maximum reportable spread KSPLT Real Minimum reportable spread TIXSPO Real ‘Allowable spread offset Te3SPO_ Boolean ‘Alowable spread offset enable KSPLB Rear Maximum allowable bast KSPLO Real ‘Allowable bias removal time constant Le3SPMB. Boolean ‘Allowable bias enable io Real Exhaust TOs ranked by value KSPr Real ‘Allowable spread gain constant KSP2 Real ‘Allowable spread gain constant KSPI3 Real ‘Allowable spread gain constant KSPa Real ‘Allowable spread gain constant [e3SPM Boolean ‘Spread alarm permissive OTT Unsigned integer Index of TC positions array TXTOTTC Unsigned Integer ‘Total number of TCs configured Outputs Name Data Type [Description [ero Real Highest compressor temperature LIGTDA, Boolean CTD limited) TTXSPL Real [Allowable spread temperature BIAS Real Filtered bias value TTXSP1 Real Calculated temperature spread 1 TIXSP2 Real Calculated temperature spread 2 TIXSeS Real Calculated temperature spread Te0sPt Boolean Exhaust temperature spread 1 alarm 1 U60sP2 Boolean Exhaust temperature spread 1 alarm 2 T60SP3 Boolean Exhaust temperature spread 2 alarm Te0SP4 Boolean Exhaust temperature spread 3 alarm Te0SPS Boolean Exhaust temperature spread low adjacency alarm (1 to 2) Te0sPa Boolean Exhaust temperature spread low adjacency alarm (210 3) Instruction Guide GE Internal GEI-100680R "7 147 Temperature Control Feedback (TTXMV4) Block Category: TTXMV4, Gas Turbine The Temperature Control Feedback (TTXMV4) block is a uber block that will consider up to 45 sets of variables. The TTXMV4 block receives and sorts exhaust thermocouple (TC) inputs from the HO subsystem, rejects bad TCs, then averages the remaining TCs to produce a net exhaust femperature input for control and protection. The assignment to the input pins should be done in position order. The health status for each Thermocouple input is used for rejection criteria along with the value-based rejection levels present in this block. Expansion checks are done to ensure the declared size of the output arrays is ‘equal to the number of rubber input TC assignments, Tren —Biteo: txToTTo} 3 Cony R HuTHo—] te TTxD1t] t ‘npat Sort oxi fut : a into R te Thxb2 TxD] k mrxot| | faray luo TC44— vray ler TXNUMTC oe Blair ates} frrxpatn) Fo | =x emainger - orcludin ihe trxu® Bhexcoer— andiowest Lrtkxco k +. He e ITTKoT3. eae fro La0TXA, + 8 a R irexe A oe R tle ft |e B rtkorz on bo fto} tata} corr] A wal | LD bee inxor 5 5 I vistRRST- a ace Bl rrkxta Bt ap 8) TFINH froHiatcnbLectrel ® LJ RReser| ka6TxT TIXMVA Block 268 GEL-100600R ‘Mark Vie Controller Turbine Block Library GE internal Inputs Name Data Type [Description Teo Real Exhaust thermocouple value 0 HOTHO Boolean Health status of exhaust thermocouple 0 t 7 1 rreaa Real Exhaust thermocouple value 44 HUTHaa Boolean Health status of exhaust thermocouple 44 KeGTXT Double integer TBBTXT time delay (milliseconds) TKXCOEF Real Temperature compensation coefficient TTKXCO Real Temperature offset TTKOTS Real [Over temperature alarm incremental seting TTRXB Real Temperature control reference TTKOTZ Real [Over temperature trip incremental setting TTKOTA Real [Over temperature tip Isothermal seting MSTRRST Boolean Master reset TTKXMS Real Failed TC alarm constant LTFINH Boolean Tnhibit TC fault logic variable Outputs Name Data Type [Description TxTOTTS Unsigned Double Integer | Total number of TOs configured TAXDTT Real Tnput TOs ranked by position array SXDUT Unsigned Double Integer __| Index of TC positions array TTXDZT Real Tnput TOs ranked by value array FXNUMTC Unsigned Double Integer ___| Number of TOs used in computation (not rejected) TiXM Real [Average exhaust temperature L30TXA Boolean [Over temperature alarm LeeTXT Boolean Exhaust over temperature tip Te6TFE Boolean Exhaust thermocouples open tip Instruction Guide GEH-100680R 269 GE Internal

You might also like