Automation Controller
Product Overview
w
q e r t y u i o a
s d f g h j k
Features
The SEL-3350 provides a rugged, easy-to-use automa- Mass Storage. The SEL-3350 contains two 2.5-inch
tion controller for substation, industrial, or other harsh SATA drive slots that support field-servicing.
environments. The following features are included in the High-performance, industrial-rated, solid-state
system: drives (SSD) are available as ordering options.
x86-64 Architecture. The Intel Atom microprocessor Display Interface. A single DisplayPort interface
architecture delivers high performance and broad enables connecting to as many as three indepen-
operating system and software compatibility. dent high-definition displays simultaneously via
Four processor cores and 8 GB of RAM enable DisplayPort Multi-Stream Transport (MST). Dig-
running multiple time-critical applications simul- ital audio can be streamed through the Display-
taneously. Port interface for simple integration and high-
definition surround-sound.
Operating System Choices. You can purchase the
SEL-3350 with or without one of the optional USB Connectivity. Front- and rear-panel USB ports
operating systems, like SEL RTAC, provide connections to keyboards, mice, and
SEL Blueframe, or Microsoft Windows, to add many other USB peripherals. Each port has a
flexibility, functionality, and security. current-limiting function to protect the system
from external short circuits while still supporting
Form Factor. The 19-inch rack-mount chassis is high-power USB devices.
designed for substation and industrial control
applications. The system includes I/O connec- Ethernet. Five Ethernet ports provide high-speed net-
tions for linking to networks, peripherals, storage, work connectivity through five independent
video, alarm, and serial I/O—all with protection Ethernet controllers, enabling connections to
against electrical shock and surge. independent networks or redundant paired net-
work connections. The front Ethernet port pro-
Power Supply. A wide-range of ac/dc power supplies vides quick and secure engineering access
provides compatibility with a variety of power
without connecting to the local network. Select
sources. from RJ45 copper and small form-factor plugga-
ble (SFP) fiber-optic interfaces for the rear ports.
Serial I/O. Sixteen EIA-232/422/485 serial ports Contact Output. This output is normally controlled by
enable connection to adjacent electronic devices the SEL-3350 system alarm, to notify external
such as automation controllers, protective relays, devices when the SEL-3350 is experiencing
communications radios, and modems. Each port abnormal operating conditions. Reconfigure the
provides IRIG-B time distribution to the con- contact to control it with automation logic. This
nected devices. Form C contact supports both normally open and
normally closed operation.
IRIG-B Input/Output. Synchronize the system time to a
satellite clock by using the high-precision Watchdog. If a system lockup is detected, the watch-
IRIG-B input. Distribute IRIG-B to downstream dog can trigger a system reboot in order to
devices by using the IRIG-B output and serial attempt to return to a normal operating state.
ports.
Remote Management. The SEL-3350 supports remote
Universal Contact Input. This configurable wide- access over Ethernet.
range input can be used to monitor status changes
in switches and contact outputs, or measure
actual voltage for applications like battery moni-
toring.
Applications
The SEL-3350 is an extremely versatile and powerful automation controller that may be used for many applications. You
can customize the SEL-3350 with factory-installed options and/or third-party software to meet the requirements of your
application. Several of the most popular applications are listed in Table 1 and shown later in this section.
Application Description
Intelligent Port switch Connects a single serial port to multiple serial ports.
Network Gateway Port server network gateway connects a single network port to multiple serial ports.
Protocol Gateway Connects multiple systems that use different protocols.
Time-Synchronization Source Selects the best time from different sources and provides either or both IRIG-B and
Network Time Protocol (NTP) outputs to connected devices.
Synchrophasor Processor Connects phasor measurement unit (PMU) data to other devices and processes through
protocol conversion.
SCADA Data Concentrator (Remote Terminal Unit Monitors digital and analog inputs to transmit to a central location with standard
(RTU)/Programmable Logic Controller (PLC)) SCADA protocols.
Security Gateway Provides firewall protection to incoming Ethernet communication as well as encryp-
tion for individual Ethernet sessions.
Logic Processor (Automation) Monitors digital and analog inputs to transmit to a central location plus performs IEC
61131-3 logic.
Local or Remote HMI Provides visualization and control via on-board video output ports and through remote
web browser access.
SEL-9192 SEL-9192
SEL-9192 USB Modem
SEL-2407 SEL-3350
SEL-351 SEL-451
Network Gateway
The SEL-3350 comes standard with four rear Ethernet ports that you can configure to make serial-connected devices
available to high-speed networks. The optional SEL RTAC operating system supports virtual terminal connections
through the Ethernet ports. For example, Ethernet users can establish secure Telnet sessions and communicate with an
intelligent electronic device (IED) connected to the SEL-3350 with the SEL RTAC operating system. An example of this
application is shown in Figure 2.
The SEL-3350 comes standard with four rear Ethernet ports that you can configure to make serial-connected devices
available to high-speed networks, as shown in Figure 2.
Figure 2.2
Engineering Modem
Other IED
SEL-421 SEL-751A
SEL-351 SEL-451
••• SEL-735
Protocol Gateway
Collect downstream data with client protocols and send these data to your upstream HMI, RTU, or SCADA master with
server protocols, converting the data from one protocol to another in the process. The SEL-3350 is great for data concen-
tration when combined with the optional SEL RTAC operating system that provides multitasking/multiuser and data
handling capabilities. An example of this application is shown in Figure 3.
Figure 2.3
SCADA
DNP3
Other IED
SEL-751A
DNP3
SEL-351 SEL-735
SEL-735
IEC 61850
SEL-421 SEL-451
••• Modbus
SEL-2440 DPAC SEL-751A SEL-2440 DPAC
Time-Synchronization Source
Synchronize the time clocks in attached devices that accept a demodulated IRIG-B time signal. The demodulated
IRIG-B signal is regenerated in the SEL-3350 from an external modulated or demodulated source, such as a GPS satel-
lite clock receiver or other serial or Ethernet communications. If an external clock source is not available, the SEL-3350
generates an IRIG-B signal from its internal clock, allowing device synchronization to a common clock for improved
sequence-of-events analysis. An example of this application is shown in Figure 4. The system time may also be set on
the SEL-3350 from a Simple Network Time Protocol (SNTP) source, a Network Time Protocol (NTP) source, or a Pre-
cision Time Protocol (PTP) source.
Figure 2.4
SEL-2407
SEL-351 SEL-451
Synchrophasor Processor
Move synchrophasor data to SCADA operations centers by using standard protocols, such as DNP3. Include time stamps
and time quality in the SCADA message to allow for system-wide use of synchrophasor data. With the logic engine in
the optional SEL RTAC operating system, you can perform complex math and logic calculations on synchrophasor data
collected from SEL relays and other IEEE C37.118-compliant devices. An example of this application is shown in
Figure 5.
Figure 2.5
Local HMI
SEL-2407
GPS Clock
SEL-3350
SEL-2730M
PMU •••
SEL-421 SEL-735
SEL-751A
SEL-351 SEL-451
Local HMI
Engineering SCADA
SEL-9192
USB Modem SEL-9192
SEL-2407
Ethernet Switch
GPS Clock
SEL-3350 SEL-2730M
Modbus
Serial SEL ASCII
DNP3
Other IED SEL-751A
DNP3
SEL-735
SEL-351
SEL-735
IEC 61850
SEL-421 SEL-451
••• Modbus
SEL-2440 DPAC SEL-751A SEL-2440 DPAC
Security Gateway
Combine the SEL-3350 with a secure operating system like the SEL RTAC operating system and third-party application
software that can provide secure engineering access and other Ethernet tunneled serial communications on the automa-
tion network with Secure Sockets Layer (SSL)/Transport Layer Security (TLS) or Secure Shell (SSH) encryption.
Implement system security auditing, logging, and password restrictions to enforce NERC standards. Comply with role-
based requirements by implementing per-user security profiles. Optionally incorporate serial and wireless encrypting
devices to further secure communication to any device. An example of this application is shown in Figure 7.
Figure 2.7
SCADA
Dial-Out
Wireless Telephone
Encryption
Alarm
SEL-3060
Notification Engineering
SEL-2407 SEL-3010 SSH, TLS Encryption, and
User Account Management
GPS Clock
SEL-3350 SEL-2725 Ethernet
Switch
SEL-3025 Sensors
- Door
- Panel/Cabinet SEL-2440 DPAC
Serial - Motion
Encryption - Fence
...
SEL-751A
SEL-3025 Alarms
- Visible SEL-751A
- Audible
- Lighting
...
SEL-351
Engineering
SEL-751A
SEL-751A
Ethernet Switch
SEL-421
9.43 9.44
[239.5] [239.8]
1.01 1.00
[25.7] TOP [25.4] TOP
19.00 19.80
[482.6] 1.25
[502.9]
[31.8]
SIDE
4X Ø.25
17.63 [Ø6.4]
LEGEND [447.8]
in
[mm]
1.80 1.25
18.31 [31.8]
[45.7]
[465.1]
Specifications
Introduction
SEL-3350 and Automation
Specifications Controller
Compliance Operating Environment
Operating Temperature
Designed and manufactured under an ISO 9001 certified quality Range: –40° to +85°C (–40° to +185°F)*
management system
* Requires Industrial-Grade SSDs. See SEL Application Note,
47 CFR 15B Class A “Determining Solid-State Drive (SSD) Lifetimes for SEL Rugged
This equipment has been tested and found to comply with the limits Computers” (AN2016-03).
for a Class A digital device, pursuant to part 15 of the FCC Rules.
Note:.UL ambient 40°C. See the instruction manual safety information for
These limits are designed to provide reasonable protection against
additional restrictions.
harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can Storage Temperature
radiate radio frequency energy and, if not installed and used in Range: –40° to +85°C (–40° to +185°F)
accordance with the instruction manual, may cause harmful Relative Humidity: 5%–95% noncondensing
interference in which case the user will be required to correct the
interference at his own expense. Insulation Class: 1
UL Listed to U.S. and Canadian safety standards Pollution Degree: 2
(File E220228; NRAQ) Overvoltage Category:
CE Mark
RoHS Compliant Maximum Atmospheric
Category
Altitude Pressure
General
Category II 5,000 m 54–110 kPa
SEL Operating Systems
SEL Real-Time Automation Controller (RTAC) Weight
SEL Blueframe 2.72 kg (6 lb) maximum
Supported Third-Party Operating Systems
Peripheral Connections
Microsoft Windows 10*
Microsoft Windows Server 2019* Video and Audio
CentOS Linux 7/8 Intel HD Graphics 500 Controller
Red Hat Enterprise Linux 7/8
Ubuntu 16.04/18.04 LTS DisplayPort 1.2 output
* Orderable as a factory-installed option Up to three displays via DisplayPort MST
CPU Intel Display Audio digital audio output
Intel Atom x5-E3940 Maximum resolution: 4096 x 2160 @ 60 Hz, one display
Cores/Threads: 4/4 1920 x 1200 @ 60 Hz, three displays
Frequency: 1.6 GHz Cable length <10 m for Surge Immunity compliance
Cache: 2 MB L2 USB
RAM 2 front-panel ports, USB 3.1
4 rear-panel ports, USB 2.0
8 GB DDR3L ECC PC3-1600 (800 MHz) 1 internal Type-A port, USB 2.0
Mass Storage 1,500 mA maximum combined current
Cable length <2 m for Electromagnetic Compatibility Immunity
Supports two 2.5 inch SATA Drives compliance
SATA III 6.0 Gbps
Optional SATA Drives: Industrial-Grade SLC SSD,
Communications Ports
30–250 GB, 10-year warranty Ethernet
Industrial-Grade iMLC SSD,
120–480 GB, 5-year warranty SEL gigabit Ethernet controllers
Consumer-Grade MLC SSD, 1 front-panel 10/100/1,000 Mbps port, RJ45
240–1920 GB, 3-year warranty
4 rear-panel 10/100/1,000 Mbps ports
BIOS
Configurations: 4 RJ45 copper ports
AMI UEFI 4 SFP fiber-optic ports
2 RJ45 and 2 SFP fiber-optic ports
Real-Time Clock/Calendar
See Surge Immunity: for cable length restrictions
Battery Type: IEC No. BR-2330A Lithium
Battery Life: 10 years with power
Serial
2 years without power SEL multiport serial controller
Trusted Platform Module 16 EIA-232/422/485 Ports: RJ45 connectors
300–115,200 bps
Infineon SLB 9670VQ2.0 TPM 2.0 256 byte TX and RX FIFOs each port
+5 Vdc port power, 500 mA of shared
current
IRIG-B output
See Surge Immunity: for cable length restrictions
Technical Support
We appreciate your interest in SEL products and services. If you have questions or comments, please contact us at:
Schweitzer Engineering Laboratories, Inc.
2350 NE Hopkins Court
Pullman, WA 99163-5603 U.S.A.
Tel: +1.509.338.3838
Fax: +1.509.332.7990
Internet: selinc.com/support
Email: [email protected]
*PDS3350-01*
This product is covered by the standard SEL 10-year warranty. For warranty details, visit
selinc.com or contact your customer service representative.