3350-1 DS 20210720-Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

SEL-3350-1 

Automation Controller

Key Features and Benefits


The SEL-3350 uses a high-performance x86-64 architecture processor to support modern operating systems (OS) like
SEL Realtime Automation Controller (RTAC), SEL Blueframe, Microsoft Windows, and Linux. The extremely rugged
hardware of the SEL-3350 enables you to use your choice of an operating system and software in very harsh environ-
ments that are not suitable for general purpose computers.
➤ Flexible. Run SEL RTAC, SEL Blueframe applications, Windows operating systems, or Linux operating
systems—a single platform for all your control and automation needs.
➤ SEL Worldwide, Ten-Year Product Warranty. Have confidence in your solution and know that SEL will
support you through the life of the product.
➤ Full Industrial Temperature Range. With a wide –40 to +85°C (–40 to +185°F) operating temperature range, the
SEL-3350 will run your applications in the harshest environmental conditions.
➤ Extensive Communications. Sixteen serial ports; a configurable I/O interface for alarms, control, or
measurements; and five Ethernet ports with copper and fiber configurations provide you with a rich mix of
interfaces for your communications needs.
➤ Maximum Value. When comparably equipped, the SEL-3350 delivers five times the performance of the
SEL-3530 Real-Time Automation Controller (RTAC) at a similar price.

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


2

Product Overview
w

q e r t y u i o a

s d f g h j k

q LED lamp test button s DisplayPort monitor connection technology


w Alarm and operational status LED indicators d Four USB 2.0 ports
e Hard disk drive activity LED f 16 built-in RJ45 EIA-232 ports
r Ethernet port link status and network LEDs g Four high-speed Gigabit Ethernet port with the following
t Serial port Transmit and Receive LEDs configuration options:
• 4 RJ45 ports
y Four programmable bicolor LEDs • 2 RJ45 and 2 small form-factor pluggable (SFP) ports
u Front heat sink and no fans or moving parts • 4 SFP ports
i Front Gigabit Ethernet port h Configurable digital/analog input
o Two front-panel USB 3.1 ports j Form C alarm contact output
a Two hot-swappable SSDs k Built-in power supply connections

Features
The SEL-3350 provides a rugged, easy-to-use automa- Mass Storage. The SEL-3350 contains two 2.5-inch
tion controller for substation, industrial, or other harsh SATA drive slots that support field-servicing.
environments. The following features are included in the High-performance, industrial-rated, solid-state
system: drives (SSD) are available as ordering options.
x86-64 Architecture. The Intel Atom microprocessor Display Interface. A single DisplayPort interface
architecture delivers high performance and broad enables connecting to as many as three indepen-
operating system and software compatibility. dent high-definition displays simultaneously via
Four processor cores and 8 GB of RAM enable DisplayPort Multi-Stream Transport (MST). Dig-
running multiple time-critical applications simul- ital audio can be streamed through the Display-
taneously. Port interface for simple integration and high-
definition surround-sound.
Operating System Choices. You can purchase the
SEL-3350 with or without one of the optional USB Connectivity. Front- and rear-panel USB ports
operating systems, like SEL RTAC, provide connections to keyboards, mice, and
SEL Blueframe, or Microsoft Windows, to add many other USB peripherals. Each port has a
flexibility, functionality, and security. current-limiting function to protect the system
from external short circuits while still supporting
Form Factor. The 19-inch rack-mount chassis is high-power USB devices.
designed for substation and industrial control
applications. The system includes I/O connec- Ethernet. Five Ethernet ports provide high-speed net-
tions for linking to networks, peripherals, storage, work connectivity through five independent
video, alarm, and serial I/O—all with protection Ethernet controllers, enabling connections to
against electrical shock and surge. independent networks or redundant paired net-
work connections. The front Ethernet port pro-
Power Supply. A wide-range of ac/dc power supplies vides quick and secure engineering access
provides compatibility with a variety of power
without connecting to the local network. Select
sources. from RJ45 copper and small form-factor plugga-
ble (SFP) fiber-optic interfaces for the rear ports.

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


3

Serial I/O. Sixteen EIA-232/422/485 serial ports Contact Output. This output is normally controlled by
enable connection to adjacent electronic devices the SEL-3350 system alarm, to notify external
such as automation controllers, protective relays, devices when the SEL-3350 is experiencing
communications radios, and modems. Each port abnormal operating conditions. Reconfigure the
provides IRIG-B time distribution to the con- contact to control it with automation logic. This
nected devices. Form C contact supports both normally open and
normally closed operation.
IRIG-B Input/Output. Synchronize the system time to a
satellite clock by using the high-precision Watchdog. If a system lockup is detected, the watch-
IRIG-B input. Distribute IRIG-B to downstream dog can trigger a system reboot in order to
devices by using the IRIG-B output and serial attempt to return to a normal operating state.
ports.
Remote Management. The SEL-3350 supports remote
Universal Contact Input. This configurable wide- access over Ethernet.
range input can be used to monitor status changes
in switches and contact outputs, or measure
actual voltage for applications like battery moni-
toring.

Models and Options


➤ Power Supply
Models
➢ 24–48 Vdc
Complete ordering information is not provided in this
➢ 48–125 Vdc or 110–120 Vac
instruction manual. See the latest SEL-3350 model
option table at selinc.com. ➢ 125–250 Vdc or 120–240 Vac
➤ Rear Ethernet Port Configurations
➢ 4 RJ45 copper ports (10/100/1,000 Mbps)
Options
➢ 4 SFP fiber-optic ports (supports 100 and
The SEL-3350 has the following options and features: 1,000 Mbps modules)
➤ Operating System ➢ 2 RJ45 copper ports and 2 SFP fiber-optic ports
Order with no operating system or choose one of ➢ Optional SFP fiber-optic modules
the following options:
➤ SATA Drives
➢ SEL Realtime Automation Controller (RTAC) Select as many as two SATA drives
➢ SEL Blueframe with optional SEL applications ➢ Industrial-grade single-level cell (SLC) drives:
➢ Microsoft Windows 10 with optional software 32 to 256 GB, 10-year warranty
applications ➢ Industrial-grade multi-level cell (iMLC) drives:
➢ Microsoft Windows Server with optional 120 to 480 GB, 5-year warranty
software applications ➢ Consumer-grade multi-level cell (MLC) drives:
➤ Conformal Coating 256 GB to 2 TB, 3-year warranty, reduced
➢ Conformally coated circuit boards operating temperature rating
➤ Mounting ➤ Software

➢ Horizontal 19-inch rack ➢ Software applications from SEL and third


parties
➢ Horizontal panel
➢ Available options depend on operating system
choice

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


4

Applications
The SEL-3350 is an extremely versatile and powerful automation controller that may be used for many applications. You
can customize the SEL-3350 with factory-installed options and/or third-party software to meet the requirements of your
application. Several of the most popular applications are listed in Table 1 and shown later in this section.

Table 1 Popular Applications

Application Description

Intelligent Port switch Connects a single serial port to multiple serial ports.
Network Gateway Port server network gateway connects a single network port to multiple serial ports.
Protocol Gateway Connects multiple systems that use different protocols.
Time-Synchronization Source Selects the best time from different sources and provides either or both IRIG-B and
Network Time Protocol (NTP) outputs to connected devices.
Synchrophasor Processor Connects phasor measurement unit (PMU) data to other devices and processes through
protocol conversion.
SCADA Data Concentrator (Remote Terminal Unit Monitors digital and analog inputs to transmit to a central location with standard
(RTU)/Programmable Logic Controller (PLC)) SCADA protocols.
Security Gateway Provides firewall protection to incoming Ethernet communication as well as encryp-
tion for individual Ethernet sessions.
Logic Processor (Automation) Monitors digital and analog inputs to transmit to a central location plus performs IEC
61131-3 logic.
Local or Remote HMI Provides visualization and control via on-board video output ports and through remote
web browser access.

Intelligent Port Switch


The flexible communications parameters of the SEL RTAC operating system available on the SEL-3350 make it a great
choice for almost any port switching application. Although RTAC multitasking/multiuser and data handling capabilities
make the SEL-3350 a very powerful remote automation controller, it is still an economical choice for port switching
applications. The time-synchronization capabilities of the SEL-3350 add to its value in this application. An example of
this application is shown in Figure 1.
Figure 2.1

Engineering Local HMI


SEL-9192 USB Modem

SEL-9192 SEL-9192
SEL-9192 USB Modem

SEL-2407 SEL-3350

Other IED •••


SEL-421
SEL-751A SEL-735

SEL-351 SEL-451

Figure 1 Engineering Communication Through a Serial Access Point

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


5

Network Gateway
The SEL-3350 comes standard with four rear Ethernet ports that you can configure to make serial-connected devices
available to high-speed networks. The optional SEL RTAC operating system supports virtual terminal connections
through the Ethernet ports. For example, Ethernet users can establish secure Telnet sessions and communicate with an
intelligent electronic device (IED) connected to the SEL-3350 with the SEL RTAC operating system. An example of this
application is shown in Figure 2.
The SEL-3350 comes standard with four rear Ethernet ports that you can configure to make serial-connected devices
available to high-speed networks, as shown in Figure 2.
Figure 2.2

Engineering Modem

SSH, TLS Encryption,


and User Account
Management Local HMI
SEL-2725
Ethernet
Switch
SEL-2407
GPS Clock
SEL-3350

Other IED
SEL-421 SEL-751A

SEL-351 SEL-451
••• SEL-735

Figure 2 Engineering Communication Through a Network Access Point

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


6

Protocol Gateway
Collect downstream data with client protocols and send these data to your upstream HMI, RTU, or SCADA master with
server protocols, converting the data from one protocol to another in the process. The SEL-3350 is great for data concen-
tration when combined with the optional SEL RTAC operating system that provides multitasking/multiuser and data
handling capabilities. An example of this application is shown in Figure 3.
Figure 2.3

SCADA

Engineering Local HMI


SEL-9192
USB Modem
SEL-2407
GPS Clock SEL-9192
SEL-3350
SEL-2725
Modbus Ethernet
Serial SEL ASCII Switch

DNP3
Other IED
SEL-751A
DNP3

SEL-351 SEL-735
SEL-735
IEC 61850
SEL-421 SEL-451
••• Modbus
SEL-2440 DPAC SEL-751A SEL-2440 DPAC

Figure 3 Protocol Conversion

Time-Synchronization Source
Synchronize the time clocks in attached devices that accept a demodulated IRIG-B time signal. The demodulated
IRIG-B signal is regenerated in the SEL-3350 from an external modulated or demodulated source, such as a GPS satel-
lite clock receiver or other serial or Ethernet communications. If an external clock source is not available, the SEL-3350
generates an IRIG-B signal from its internal clock, allowing device synchronization to a common clock for improved
sequence-of-events analysis. An example of this application is shown in Figure 4. The system time may also be set on
the SEL-3350 from a Simple Network Time Protocol (SNTP) source, a Network Time Protocol (NTP) source, or a Pre-
cision Time Protocol (PTP) source.
Figure 2.4

SEL-2407

GPS Clock SEL-3350

Other IED •••


SEL-421
SEL-751A SEL-735

SEL-351 SEL-451

Figure 4 Distribute Time With Serial Communications Cable

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


7

Synchrophasor Processor
Move synchrophasor data to SCADA operations centers by using standard protocols, such as DNP3. Include time stamps
and time quality in the SCADA message to allow for system-wide use of synchrophasor data. With the logic engine in
the optional SEL RTAC operating system, you can perform complex math and logic calculations on synchrophasor data
collected from SEL relays and other IEEE C37.118-compliant devices. An example of this application is shown in
Figure 5.
Figure 2.5

Local HMI

SEL-2407
GPS Clock
SEL-3350

SEL-2730M

PMU •••
SEL-421 SEL-735
SEL-751A

SEL-351 SEL-451

Figure 5 System Control and Synchrophasor Data Concentration

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


8

SCADA Data Concentrator


Use the SEL-3350 with your protective relays and other IEDs as the substation SCADA data concentrator (RTU/PLC).
You can configure the SEL-3350 with SEL RTAC operating system to collect and view station-wide sequential events
recorder (SER) records and event reports. Retrieve asset optimization data from SEL IEDs or other IEDs to maintain
system reliability. Access the remote SEL-3350 through the Ethernet connection to manage users, view diagnostics, and
access logs. Establish a remote connection with any IED connected to the SEL-3350 through engineering access com-
munications channels. Use the SEL Fast Message protocol to maintain SCADA control and metering updates throughout
the engineering access connection. Remotely manage protection and control settings in connected relays by using SEL
Grid Configurator SEL-5037 Software. An example of this application is shown in Figure 6.
Figure 2.6

Local HMI

Engineering SCADA
SEL-9192
USB Modem SEL-9192
SEL-2407
Ethernet Switch
GPS Clock
SEL-3350 SEL-2730M
Modbus
Serial SEL ASCII
DNP3
Other IED SEL-751A
DNP3

SEL-735
SEL-351
SEL-735
IEC 61850

SEL-421 SEL-451

••• Modbus
SEL-2440 DPAC SEL-751A SEL-2440 DPAC

Figure 6 SCADA Communication Through a Single Access Point

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


9

Security Gateway
Combine the SEL-3350 with a secure operating system like the SEL RTAC operating system and third-party application
software that can provide secure engineering access and other Ethernet tunneled serial communications on the automa-
tion network with Secure Sockets Layer (SSL)/Transport Layer Security (TLS) or Secure Shell (SSH) encryption.
Implement system security auditing, logging, and password restrictions to enforce NERC standards. Comply with role-
based requirements by implementing per-user security profiles. Optionally incorporate serial and wireless encrypting
devices to further secure communication to any device. An example of this application is shown in Figure 7.
Figure 2.7

SCADA

Dial-Out
Wireless Telephone
Encryption
Alarm
SEL-3060
Notification Engineering
SEL-2407 SEL-3010 SSH, TLS Encryption, and
User Account Management
GPS Clock
SEL-3350 SEL-2725 Ethernet
Switch
SEL-3025 Sensors
- Door
- Panel/Cabinet SEL-2440 DPAC
Serial - Motion
Encryption - Fence
...
SEL-751A
SEL-3025 Alarms
- Visible SEL-751A
- Audible
- Lighting
...
SEL-351

Figure 7 Security Through a Single Access Point

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


10

Logic Processor (Automation)


Combine the SEL-3350 with the powerful logic engine of the SEL RTAC operating system to automate existing installa-
tions with modern IEC 61131 applications. Ensure compatibility with any SEL device through the MIRRORED BITS pro-
tocol. Take advantage of multiprotocol support to collect SCADA information, process control commands, and SNTP/
NTP time synchronization through a single communications link to each Ethernet device. Scale values and calculate
logic in a familiar IEC 61131 configuration environment. The SEL RTAC operating system provides secure, encrypted
communication to any device on the substation network or serial channel. An example of this application is shown in
Figure 8.
Combine the SEL-3350 with third-party applications that have a logic engine in order to automate existing installations
with modern IEC 61131 applications. Take advantage of multiprotocol support to collect SCADA information, process
control commands, and SNTP/NTP time synchronization through a single communications link to each Ethernet device.
Scale values and calculate logic in a familiar IEC 61131 configuration environment. An example of this application is
shown in Figure 8.
Figure 2.8

Engineering

SSH, TLS Encryption, and


SEL-2407 User Account Management
GPS Clock
SEL-3350 SEL-2725

SEL-751A

SEL-751A
Ethernet Switch

SEL-421

SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC


SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC
SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC
SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC SEL-2440 DPAC

Figure 8 Automate and Integrate With Communication and Logic

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


11

Diagrams and Dimensions

Figure 9 SEL-3350 Rear Panel Diagrams

RACK MOUNT PANEL MOUNT

9.43 9.44
[239.5] [239.8]

1.01 1.00
[25.7] TOP [25.4] TOP

19.00 19.80
[482.6] 1.25
[502.9]
[31.8]

1.72 18.31 3.15


[43.7] [465.1] [80.0]
FRONT
FRONT
#10-32
STUD

SIDE
4X Ø.25
17.63 [Ø6.4]
LEGEND [447.8]
in
[mm]
1.80 1.25
18.31 [31.8]
[45.7]
[465.1]

i9392a PANEL CUTOUT


Figure 10 SEL-3350 Dimensions for Rack- and Panel-Mount Models

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


12

Specifications
Introduction
SEL-3350 and Automation
Specifications Controller
Compliance Operating Environment
Operating Temperature
Designed and manufactured under an ISO 9001 certified quality Range: –40° to +85°C (–40° to +185°F)*
management system
* Requires Industrial-Grade SSDs. See SEL Application Note,
47 CFR 15B Class A “Determining Solid-State Drive (SSD) Lifetimes for SEL Rugged
This equipment has been tested and found to comply with the limits Computers” (AN2016-03).
for a Class A digital device, pursuant to part 15 of the FCC Rules.
Note:.UL ambient 40°C. See the instruction manual safety information for
These limits are designed to provide reasonable protection against
additional restrictions.
harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can Storage Temperature
radiate radio frequency energy and, if not installed and used in Range: –40° to +85°C (–40° to +185°F)
accordance with the instruction manual, may cause harmful Relative Humidity: 5%–95% noncondensing
interference in which case the user will be required to correct the
interference at his own expense. Insulation Class: 1
UL Listed to U.S. and Canadian safety standards Pollution Degree: 2
(File E220228; NRAQ) Overvoltage Category:
CE Mark
RoHS Compliant Maximum Atmospheric
Category
Altitude Pressure
General
Category II 5,000 m 54–110 kPa
SEL Operating Systems
SEL Real-Time Automation Controller (RTAC) Weight
SEL Blueframe 2.72 kg (6 lb) maximum
Supported Third-Party Operating Systems
Peripheral Connections
Microsoft Windows 10*
Microsoft Windows Server 2019* Video and Audio
CentOS Linux 7/8 Intel HD Graphics 500 Controller
Red Hat Enterprise Linux 7/8
Ubuntu 16.04/18.04 LTS DisplayPort 1.2 output
* Orderable as a factory-installed option Up to three displays via DisplayPort MST
CPU Intel Display Audio digital audio output
Intel Atom x5-E3940 Maximum resolution: 4096 x 2160 @ 60 Hz, one display
Cores/Threads: 4/4 1920 x 1200 @ 60 Hz, three displays

Frequency: 1.6 GHz Cable length <10 m for Surge Immunity compliance

Cache: 2 MB L2 USB
RAM 2 front-panel ports, USB 3.1
4 rear-panel ports, USB 2.0
8 GB DDR3L ECC PC3-1600 (800 MHz) 1 internal Type-A port, USB 2.0
Mass Storage 1,500 mA maximum combined current
Cable length <2 m for Electromagnetic Compatibility Immunity
Supports two 2.5 inch SATA Drives compliance
SATA III 6.0 Gbps
Optional SATA Drives: Industrial-Grade SLC SSD,
Communications Ports
30–250 GB, 10-year warranty Ethernet
Industrial-Grade iMLC SSD,
120–480 GB, 5-year warranty SEL gigabit Ethernet controllers
Consumer-Grade MLC SSD, 1 front-panel 10/100/1,000 Mbps port, RJ45
240–1920 GB, 3-year warranty
4 rear-panel 10/100/1,000 Mbps ports
BIOS
Configurations: 4 RJ45 copper ports
AMI UEFI 4 SFP fiber-optic ports
2 RJ45 and 2 SFP fiber-optic ports
Real-Time Clock/Calendar
See Surge Immunity: for cable length restrictions
Battery Type: IEC No. BR-2330A Lithium
Battery Life: 10 years with power
Serial
2 years without power SEL multiport serial controller
Trusted Platform Module 16 EIA-232/422/485 Ports: RJ45 connectors
300–115,200 bps
Infineon SLB 9670VQ2.0 TPM 2.0 256 byte TX and RX FIFOs each port
+5 Vdc port power, 500 mA of shared
current
IRIG-B output
See Surge Immunity: for cable length restrictions

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


13

Time-Code Inputs and Outputs Short-Time Thermal


Withstand**: 50 A for 1 s
Time-Code Inputs Limiting Making
One BNC IRIG-B Input Capacity**: 1,000 W @ 250 Vdc (L/R = 40 ms)
Format: IRIG-B002 or -B004 (demodulated) Limiting Breaking 10,000 operations
Capacity/Electrical 10 operations in 4 s, 
On (1) State: Vih  2.2 V Endurance**: followed by 2 min idle
Off (0) State: Vil  0.8 V
Nominal Input Impedance: 3.3 k Inductive Break
Accuracy: 100 ns Rated Voltage Resistive Break L/R = 40 ms (DC)
PF = 0.4 (AC)
Note: IRIG-B004 control bits comply with IEEE C37.118.1-2011 
(reverse compatible with IRIG-B000 and IEEE C37.118-2005). 24 Vdc 0.75 Adc 0.75 Adc
Time-Code Outputs 48 Vdc 0.63 Adc 0.63 Adc
One BNC IRIG-B Output, 16 RJ45 Serial/IRIG-B Outputs
125 Vdc 0.30 Adc 0.30 Adc
Format: IRIG-B004 (demodulated)
250 Vdc 0.20 Adc 0.20 Adc
On (1) State: Voh  2.4 V
Off (0) State: Vol  0.8 V 110 Vrms 0.30 Arms 0.30 Arms

Output Drive Capacity 240 Vrms 0.20 Arms 0.20 Arms


BNC IRIG-B Out: TTL 240 mA (>20 ) * Per UL 508.
Each Serial Port: TTL 6 mA (>400 ) ** Parameters verified by SEL per IEC 60255-1:2009 and 
Note: IRIG-B004 control bits comply with IEEE C37.118.1-2011  IEEE C37.90-2005.
(reverse compatible with IRIG-B000 and IEEE C37.118-2005).
Power Supplies
Contact Inputs and Outputs General
IN101 Universal Contact Input (Bipolar Operation) Typical Burden: <20 W, <50 VA
Rated Voltage Range: 24–250 Vdc, 110–240 Vac 50/60 Hz Maximum Burden: <62 W, <150 VA
Operational Voltage Range: 0–300 Vdc, 0–264 Vac 45–65 Hz DC Ripple: 15% per IEC 60255-26:2013
DC Measurement Peak Inrush: 20 A
Accuracy*: ±0.5%, ±250 mV
Input Isolated From
AC Measurement Chassis Ground: Yes
Accuracy*: ±2.5%, ±500 mV
Low Voltage 24–48 Vdc
RMS Filter Period: 1s
Voltage Rating: 24–48 Vdc
Pickup/Dropout Level
Setting Range: 15–265 Vdc/Vac rms Voltage Range: 18–60 Vdc
Pickup/Dropout Delay Interruption*: 80 ms @ 24 Vdc, 400 ms @ 48 Vdc
Setting Range: 0–4,000 ms** Medium Voltage 48–125 Vdc or 110–120 Vac
Current Draw: 1.0–4.0 mA @ >110 Vdc/Vac
Voltage Rating: 48–125 Vdc, 110–120 Vac
0.3–4.0 mA @ 24–110 Vdc/Vac
* Intended as a measurement function only. Operational Voltage Range: 38–140 Vdc, 85–140 Vac
** Type tested with delay settings of 8 ms at < 48 V and 2 ms at  48 V. Frequency Rating: 50/60 Hz
OUT101/Alarm Contact Output Operational Frequency
Range: 30–120 Hz
Output Type: Relay, Form C break-before-make
Interruption*: 60 ms @ 48 Vdc,
Pilot Duty Ratings*: B300 600 ms @ 125 Vdc/110 Vac
24–250 Vdc, 0.27 A
Thermal Continuous Test Current: 5 A High Voltage 125–250 Vdc or 110–240 Vac
Rated Voltage**: 24–250 Vdc Voltage Rating: 125–250 Vdc, 110–240 Vac
110–240 Vrms Operational Voltage Range: 85–300 Vdc, 85–264 Vac
Note: The voltage across any of the contact output terminals must not
Frequency Rating: 50/60 Hz
exceed the rated operational voltage.
Operational Frequency
Operational Voltage**: 0–300 Vdc
Range: 30–120 Hz
0–264 Vrms
Interruption*: 200 ms @ 125 Vdc/110 Vac,
Contact Protection: MOV protection across open contacts
1,000 ms @ 250 Vdc/220 Vac
264 Vrms continuous voltage
* Tested per IEC 60255-26:2013 with a typical workload.
300 Vdc continuous voltage
Continuous Carry**: 6 A @ 70°C, 4 A @ 85°C Recommended External Overcurrent Protection
Pickup/Dropout Time**:  6 ms (resistive load) Breaker Type: Standard
Power Supply Burden**: 1 W Breaker Rating: 20 A @ 250 Vdc
Mechanical Endurance**: 10,000 no-load operations Current Breaking Capacity: 10 kA
Make (Short Duration 30 Adc Grounded Neutral Systems: Device in series with the energized
Contact Current)**: 1,000 operations @ 250 Vdc conductor
2,000 operations @ 125 Vdc
DC and Isolated Systems: Device in series with both conductors
Note: 200 ms on, 15 ms off, current interrupted by independent means.

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


14

Fuse Ratings Product Standards


Low-Voltage Power Supply F1 Communications
Type: 5x20 mm Time-Lag T Equipment in Utility IEC 61850-3:2013 Performance Class 1
Substations: IEEE 1613-2009 Performance Class 1
Current Rating: 5.0 A
Industrial Environment: IEC 61000-6-2:2005
Voltage Rating: 150 Vdc IEC 61000-6-4:2006
Breaking Capacity: 1,500 A @ 150 Vdc Electrical Equipment for IEC 61010-1:2010/AMD1:2016/
Medium-Voltage Power Supply F1 Measurement, Control, COR:2019
and Laboratory Use: UL 61010-1:2019,
Type: 5x20 mm Time-Lag T
C22.2 No. 61010-1:12
Current Rating: 3.15 A IEC 61010-2-201:2017
UL 61010-2-201:2018,
Voltage Rating: 250 Vac, 300 Vdc
C22.2 No. 61010-2-201:14
Breaking Capacity: 1,500 A @ 250 Vac, 300 Vdc
Measuring Relays and IEC 60255-1:2009
High-Voltage Power Supply F1 Protection Equipment: IEC 60255-26:2013 (Zone A)
Type: 5x20 mm Time-Lag T IEC 60255-27:2013

Current Rating: 3.15 A Programmable Controllers: IEC 61131-2:2007

Voltage Rating: 250 Vac, 300 Vdc Electrical Equipment for


Measurement, Control,
Breaking Capacity: 1,500 A @ 250 Vac, 300 Vdc and Laboratory Use: IEC 61326-1:2012

Terminal Connections EMC Immunity for


Industrial Environments: IEC 61000-6-2:2005+AC:2005
Ring Lug Screw Terminal EMC Emissions for
#8 Ring Terminal Recommended Industrial Environments: IEC 61000-6-4:2006+A1:2010
Power Wiring FDA Laser: 21 CFR Part 1040:2017 Subchapter J
FDA Notice 42
Insulation: 300 V min
Safety of Laser Products: EN 60825-1:2014
Size: 14–16 AWG
EN 60825-2:2004+A1:2007+A2:2010
Wire Type: Copper
Ring Lug Tightening Torque
Type Tests
Note: To ensure protection-level EMI and EMC performance, type tests
Minimum: 1.0 Nm (9 in-lb)
were performed using shielded Ethernet and serial cables with the shield
Maximum: 2.0 Nm (18 in-lb) grounded at both ends of the cable and using USB and video cables with
ferrite chokes. Double-shielded cables are recommended for best EMI and
Mounting Ear Tightening Torque EMC performance and required for protection-level performance on
Minimum: 0.9 Nm (8 in-lb) Ethernet ports.

Maximum: 1.4 Nm (12 in-lb) Electromagnetic Compatibility Emissions


Compression Screw Terminal Conducted and Radiated CISPR 11:2009+A1:2010
Emissions (Class A): CISPR 22:2008
Crimp Ferrule Recommended IEC 61000-6-4:2006
Input/Output Wiring IEC 61850-3:2013
FCC 15.107:2014
Insulation: 300 V min FCC 15.109:2014
Size: 14–18 AWG 47 CFR Part 15.109
47 CFR Part 15.107
Wire Type: Copper Canada ICES-001(A) / NMB-001(A)
Compression Screw Tightening Torque Harmonic Current: IEC 61000-3-2:2014
Minimum: 0.6 Nm (5 in-lb) Voltage Flicker: IEC 61000-3-3:2013
Maximum: 0.8 Nm (7 in-lb)
Electromagnetic Compatibility Immunity
Mounting Ear Tightening Torque
Conducted RF Immunity: IEC 61000-4-6:2013
Minimum: 0.18 Nm (1.6 in-lb) Severity Level: 10 Vrms
Maximum: 0.25 Nm (2.2 in-lb) Electrostatic Discharge IEC 61000-4-2:2008
Immunity: IEEE C37.90.3-2001
Grounding Screw Severity Level:
#6 Ring Terminal Recommended 2, 4, 6, 8 kV contact discharge
2, 4, 8, 15 kV air discharge
Ground Wiring
Fast Transient/Burst IEC 61000-4-4:2012
Insulation: 300 V min
Immunity: Severity Level:
Size: 14 AWG, length <3 m 4 kV, 5 kHz on power supply and
Wire Type: Copper contact I/O
2 kV, 5 kHz on communications lines
Tightening Torque
Note: Ports with lengths limited to <2 m are not evaluated in Fast Transient/
Minimum: 0.9 Nm (8 in-lb) Burst.
Maximum: 1.4 Nm (12 in-lb)

SEL-3350-1 Data Sheet Schweitzer Engineering Laboratories, Inc.


15

Power Frequency Immunity IEC 60255-26:2013 Environmental


on Binary Inputs: Severity Level:
300 V common mode Change of Temperature: IEC 60068-2-14:2009
150 V differential mode Severity Level:
50/60 Hz 5 cycles, 1°C per minute ramp
–40° to +85°C
Conducted Common Mode IEC 61850-3:2013
Disturbance: Severity Level (Power Input Port): Cold, Operational: IEC 60068-2-1:2007
30 V continuous Severity Level: 16 hours at –40°C
300 V for 1 s Cold, Storage: IEC 60068-2-1:2007
50/60 Hz Severity Level: 16 hours at –40°C
Magnetic Field Immunity: IEC 61000-4-8:2009 Damp Heat, Cyclic: IEC 60068-2-30:2005
Severity Level: Severity Level:
1,000 A/m for 3 s 12 + 12-hour cycle
100 A/m for 60 s 25° to 55°C, 6 cycles, >93% RH
IEC 61000-4-9:2016
Severity Level: Damp Heat, Steady: IEC 60068-2-78:2012
1,000 A/m Severity Level:
IEC 61000-4-10:2016 40°C, 240 hours, >93% RH
Severity Level: Dry Heat, Operational: IEC 60255-1:2009
100 A/m for 2 s at  IEC 61850-3:2013
100 kHz and 1 MHz IEC 60068-2-2:2007
Power Supply Immunity: IEC 61000-4-11:2004 Severity Level: 16 hours at 85°C
IEC 61000-4-17:1999+ Dry Heat, Storage: IEC 60255-1:2009
A1:2001+A2:2008 IEC 61850-3:2013
IEC 61000-4-29:2000 IEC 60068-2-2:2007
Radiated Radio Frequency: IEC 61000-4-3:2006+A1:2007+A2:2010 Severity Level: 16 hours at 85°C
Severity Level: 10 V/m Free Fall: IEEE 1613-2009
IEEE C37.90.2-2004 Severity Level: 100 mm
Severity Level: 20 V/m
Vibration: IEC 60255-21-1:1988
Slow Damped Oscillatory IEC 61000-4-18:2006+A1:2010 Severity Level:
Waves: Severity Level: Endurance Class 2
Power supply and contact I/O Response Class 2
2.5 kV peak common mode IEC 60255-21-2:1988
1.0 kV peak differential mode Severity Level:
Communications ports Shock Withstand, Bump Class 1
1.0 kV peak common mode Shock Response Class 2
Surge Withstand IEEE C37.90.1-2012 IEC 60255-21-3:1993
Capability: Severity Level: Severity Level:
2.5 kV oscillatory Quake Response Class 2
4 kV fast transient Safety
Note: Ports with lengths limited to <2 m are not evaluated in Surge Enclosure Protection*: IEC 60529:1989+A1:1999+A2:2013
Withstand Capability and Slow Damped Oscillatory Waves. Severity Level:
Surge Immunity: IEC 61000-4-5:2005 IP4X on all sides except:
Severity Level per  IP2X on SFP cage and contact I/O
IEC 60255-26:2013*: IP1X on power supply terminals
Zone A: Note: The SFP cage is IP4X-compatible when an SFP module or dust cover
2 kV line-to-line is installed.
4 kV line-to-earth
Zone B: Dielectric Strength: IEC 60255-27:2013
1 kV line-to-line IEEE C37.90-2005
2 kV line-to-earth Severity Level:
3600 Vdc on power supply
2500 Vac on contact output, contact
Ethernet input, and BNC IRIG-B IN
IEC 60255-26 Port Serial Length 1500 Vac Ethernet ports
Length
Classification Restrictions Type tested for one minute
Restrictions
Impulse: IEC 60255-27:2013
Zone A Protection <10 m <10 m IEEE C37.90-2005
Severity Level:
Zone A Communication None <10 m
5 kV power supply, contact output,
Zone B Protection <10 m <10 m contact input, BNC IRIG-B IN
1.5 kV Ethernet ports
Zone B Communication None None *
Self declared rating.
* Ports or applications with cable lengths limited to <10 m are excluded
from the Surge test. See Peripheral Connections on page 12 and
Communications Ports on page 12 for detail.

Schweitzer Engineering Laboratories, Inc. SEL-3350-1 Data Sheet


16

Technical Support
We appreciate your interest in SEL products and services. If you have questions or comments, please contact us at:
Schweitzer Engineering Laboratories, Inc.
2350 NE Hopkins Court
Pullman, WA 99163-5603 U.S.A.
Tel: +1.509.338.3838
Fax: +1.509.332.7990
Internet: selinc.com/support
Email: [email protected]

© 2020–2021 by Schweitzer Engineering Laboratories, Inc. All rights reserved.


All brand or product names appearing in this document are the trademark or registered 2350 NE Hopkins Court • Pullman, WA 99163-5603 U.S.A.
trademark of their respective holders. No SEL trademarks may be used without written Tel: +1.509.332.1890 • Fax: +1.509.332.7990
permission. SEL products appearing in this document may be covered by U.S. and Foreign
selinc.com • [email protected]
patents.
Schweitzer Engineering Laboratories, Inc. reserves all rights and benefits afforded under
federal and international copyright and patent laws in its products, including without lim-
itation software, firmware, and documentation.
The information in this document is provided for informational use only and is subject to
change without notice. Schweitzer Engineering Laboratories, Inc. has approved only the
English language document.

*PDS3350-01*
This product is covered by the standard SEL 10-year warranty. For warranty details, visit
selinc.com or contact your customer service representative.

SEL-3350-1 Data Sheet Date Code 20210720