EDWARDS® Catalog u Mid-Sized Systems

LIFE SAFETY & INCIDENT MANAGEMENT

EST3X Life
Safety Control
System COA 6087

7165-1657:
0186/0306

S3000

Description Standard Features


EST3X represents the latest generation of life safety control panels • Up to six intelligent analog loops hosting as many as 1,500
for mid to large sized applications. With large multi-message dis- Signature Series devices per panel
plays and innovative controls, intuitive interfaces, and bold colored
• Optional integrated eight-channel digital audio
cabinets — these systems capture the imagination, and catch the
eye. But behind the LCD display is where they really shine. • 10 amp power supply with universal 94 to 264 Vac
input voltage
New microprocessors and chipsets take full advantage of the lat-
est advances in computing technology, leading to smarter, faster, • Patented Voltage Boost™ technology delivers consistent volt-
higher-capacity processing and more efficient designs. EST3X’s age — even at low battery power
patented Voltage Boost™ technology, for example, delivers consis- • Four built-in 3-amp notification/auxiliary circuits
tent voltage – even at low battery power – resulting in lighter cable
requirements and/or longer runs. That saves time and money. • Large 24-line by 40-character backlit LCD

Meanwhile, advanced communications provide integrated IP com- • Simplified operation with the SpeedTouch™ rotary control
munications via existing Ethernet networks directly to subscribed • 65 amp hour battery charger
central stations. Email and text messaging options enrich this
advanced communication environment with instant notification — • 64-node network nodes using copper and/or fiber
anywhere, any time. • Supports up to 30 R-Series remote annunciators
High performance processing also leads to powerful networking • Part of an end-to-end audio solution suitable for low frequency
features and versatile digital audio functionality. The wide range of signaling in sleeping areas
EST3X configurations include standalone operation, networking
• Space for up to three additional option cards such as extra
with up to 64 nodes, or integration with an EST3 network com-
SLC loops, amplifiers, or dialer/modem
prising as many as 64 nodes — complete with mass notification
capabilities and display of security events. • Optional Ethernet Interfaces for central station communication,
email, and diagnostics
EST3X sets a new standard in front-panel life safety control
interfaces. Its exclusive SpeedTouch™ rotary control offers nimble • 1,100 event history log
forward and back scrolling through events and options, while a • Optional earthquake hardening: OSHPD seismic pre-approval
mere tap of the control selects items with a clean fluidity of motion. for component Importance Factor 1.5
Its extra-large backlit display reveals up to eight concurrent mes-
sages, and switch/LED strips provide ample space for meaningful • UL2572 Listed for Mass Notification, UL864 UUKL Listed for
custom labels. And for end users, large tactile control buttons Smoke Control, UL864 Listed for releasing applications using
instill confidence and promote quick response when time is of the SIGA-REL
essence.

Page 1 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
Application
Application flexibility is where EST3X’s computing power is put to stallations is equally efficient as a result of these shared resources.
best use. This generation of control panels is equally at home as EST3X will accommodate up to three EST3 modules on its own
the center of a simple single-building standalone system as it is rail assembly, giving it access to such proven EST3 successes as
when part of a sophisticated life safety network serving thousands zoned amplifiers, conventional device circuits, modem communi-
of points across multiple buildings. Optional voice evacuation cators, and RS-485 functions. Meanwhile, installers familiar with
bridges the gap left by other mid-range systems. EST3 configuration will find that the two systems share many of
the same programming and diagnostic conventions.
Strong Networking
Networking is among EST3X’s strong suits. Highly efficient RS485 Local and Remote Annunciation
connectivity, plus fiber-optic communications deliver faster re- Up to 30 R-Series LCD, LED annun-
sponse times and more sophisticated diagnostic capabilities, while ciators and driver interface cards may
cost-effective remote annunciation solutions keep basic monitor- be configured for each node on the
ing and control always within reach. EST3X network. No additional nodes are
required for annunciation purposes. In
A simple EST3X network can comprise up to 64 nodes – enough addition, EST3X supports EST3 network
to serve the needs of most campuses and larger buildings. Its annunciators, while GCI and GCIX driver Up to 30 R-Series annunciators
ability to join an EST3 network with as many as 64 nodes extends interface cards provide cost-effective may be configured for each
node on the EST3X network.
EST3X’s reach into mass notification applications, security report- graphic annunciation solutions. And all
ing, as well as making it an ideal candidate for retrofits. annunciator inputs and outputs are easily programmable through
the rules and labels function of EST3X’s Software Definition Utility.
High Capacity Audio
EST3X features a full eight channels of Power to Count On
integrated digital audio with up to two min- EDWARDS’ patented Voltage Boost™ technology delivers a con-
utes of on-board programmable message sistent 22.5 Vdc – even at low battery power. This means lighter
storage. An optional high quality paging gauge cable can be used for equivalent distances compared with
microphone gives live access to local, as conventional power supplies, or longer wire runs on the same
An optional paging microphone
well as remote, audio functions. Auxiliary provides local, as well as gauge cable. Either way, this breakthrough technology saves time
inputs are available for mass notification remote, audio functions.
and equipment costs, making EST3X not only a high-performance
operations, and ZA Series amplifiers may solution — but a cost-effective one as well.
be mounted directly on the EST3X rail assembly.
EST3X’s four on-board Notification Appliance Circuits are fully syn-
High Fidelity Audio Approved for Sleeping Areas chronized to UL 1971 standards — without the need for external
EST3X is part of an end-to-end low frequency/high fidelity solu- modules or other electronics. It’s ample 10-amp power supply is
tion listed to UL 464 and UL 864. Its audio system approved for finely tuned to get the most out of EDWARDS’ widely-acclaimed
code-compliant 520 Hz signaling in sleeping areas when used in low profile Genesis notification appliances.
conjunction with:
• a factory-supplied 520 Hz audio file
• one or more of the following amplifiers: 3-ZA20A, 3-ZA20B, Dimensions
3-ZA40A, 3-ZA40B, 3-ZA95, SIGA-AA30, SIGA-AA50, 1B3- The backbox is designed for semiflush or surface mounting. Con-
125, or 1B3-250 duit and nail knockouts, keyhole style mounting holes, and wide
• one or more Genesis High Fidelity speakers wiring troughs facilitate efficiency during installation.
Consult the EST3X Compatibility List for details.  
 


 
 

Scalable IP and Cellular Communications LQ FP 


7RSYLHZ
Several popular third-party IP/Cellular communicators have been 
tested with the EST3X control panel and are compatibility listed to 

 
UL864. The IP/Cellular communicators meet NFPA72 2013 edition
  

 

requirements for sole or secondary transmission paths. Using IP/
 


Cellular communicators can reduce the cost of ownership by 

eliminating POTS lines. Please see the EST3X control panel com- 



%DFNER[ 
patibility documentation part number 3101801-EN for a full list of 


compatible communicators.


 

Seamless System Integration 

EST3X borrows much from it’s larger sibling, the venerable EST3 
Life Safety Platform. And for good reason: by integrating with the 

EST3 networking and computing environment, an EST3X control  


 
panel can serve as a cost-effective remote node for extinguishing,
smoke control, or even mass notification functions — all within the 6LGHYLHZ 6LGHYLHZ
same compliance framework.
%RWWRPYLHZ 

Retrofits and expansions benefit enormously from this arrange-


Note: Add 0.25 in (0.64 cm). to height and width dimensions to allow for knockouts
ment, but programming and equipment management for new in- when framing in the backbox for semiflush mounting.

Page 2 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
System Layout Wiring

Up to six intelligent analog loops hosting as many as 250 devices each.  Signature (initiating) Data Circuit

SLC1 SLC2 SLC3 SLC4 SLC5 SLC6


Standard 3-SDC1 Required for Class A or Class X only
3-SDDC1 3-SDDC1
(occupies one (occupies one To two-wire smoke detector
LRM expansion slot) LRM expansion slot)

Auxiliary power, +24 V


Auxiliary power, common

If shielding is used, it must be continuous


Four 3-amp Class B NACs. Four Class A NACs with CLA-PS10. and free from earth ground.
BB S A A S P BB 24+ C
H WM
LOOP1
KR
LOOP1L 1 OOP1 AUX All wiring is power limited.
NAC 1 NAC 2 NAC 3 NAC 4 SFS1-CPU Main Board

 Notification Appliance Circuits


PS10-4B
Power
supply

Normal + + + + EOL
Up to three EST3 Local Rail Modules including: resistor
Active + + + +
• Signature Series Drivers
• Zoned Amplifiers
• Modem Communicators
• Network Short Haul Modems
• Fiber Optic Communications Interfaces
• Hardwired Initiating Device Modules

Wiring is supervised and power limited.


Up to three Control/Display Modules
TB2 terminal marking indicates signal polarity when the circuit
is active. Polarity reverses when the circuit is active.
For proper circuit supervision, break the wire run at each
notification appliance and install the EOL resistor at the end of
FireWorks the circuit.
Do not loop wires around notification appliance terminals.

Ethernet  Network data circuit


(3X-ETH) A
NETWORK
OUT
A BB
IN R
X
T
X
R
T
S
C
O
M
A
RS-485
BUS
B
RS-485
BUS
1 1 1 1

RS-232
SFS1-CPU Main Board

To next
Relays: network
Up to 30 Class B 3 Form C Class A or Class X node

Annunciators.
4,000 ft. max. Aux. Power: 24  Network data circuit, Class B audio
VDC, 1.0 A total NETWORK
OUT IN R T
R
T
C
O
A
RS-485
B
RS-485
A A BB X X S M BUS BUS
1 1 1 1

3X-NET, 3X-FIB 3X-NET8, 3X-FIB8 SFS1-CPU Main Board

To next
network
3-ASU/3X-PMI node
Primary Audio Data

Or...  Network data circuit, Class A or Class X audio


NETWORK R C A B
OUT IN R T T O RS-485 RS-485
A A BB X X S M BUS BUS
1 1 1 1

SFS1-CPU Main Board

To next
UL Listed Signaling UL Listed Life Safety Detection network
3-ASU/3X-PMI node
Primary Audio Data

UL Listed Security UL Listed Mass Notification UL Listed Signaling UL Listed Life Safety Detection

Page 3 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
Main Component Assembly SFS1-CPU Main Board
EST3X systems are designed for quick assembly and easy access The SFS1-CPU main board processes all infor-
in the field. Components are modular and require no special tools mation from modules installed within the cabinet
to service or replace. as well as data received from other panels over
the network data riser. When a network card is
installed, the CPU employs a command set to
The 3-SFS1 Electronics Chassis provides
the mounting, internal power, and data determine its type.
distribution for the SFS1-CPU main board
and up to three local rail modules. It SFS1-CPU Specifications
installs over the PS10-4B Power Voltage 24 VDC
Supply. Current
Standby 115 mA at 24 VDC
Alarm 115 mA at 24 VDC
Relay outputs
Quantity 3 (alarm, supervisory, and trouble)
UL type Common
Contact arrangement Form C
Rating 30 VDC at 1 A resistive
The SFS1-CPU main board AUX power outputs
mounts to the Electronics Chassis. Quantity 2
Voltage 24 VDC, resettable or continuous
Chassis Current 1.0 A each circuit, 1.0 A total
Common Assembly
Relay Data network (RS-485)
Outputs Nodes 2 to 64 (requires optional network card)
SLC1
Signaling
Performance class Class A, Class X, or Class B
line circuit Wire type Twisted pair, 6 twists per foot, min.
Circuit length 5,000 ft. (1,524 m) between any three panels
Circuit resistance 90 Ω, max.
Circuit capacitance 0.3 μF, max.
Serial Port (RS-232)
The on-board serial port supports communication to the FireWorks
Network, SFS1-CPU graphical users interface or the FSB-PC series of protocols converters
annunciator, Main Board for ancillary communications to BMS systems.
RS-232 circuits
SLC2 Signaling Circuit length 20 ft. (6 m) max.
line circuit
Circuit resistance 13 Ω, max.
Circuit capacitance 0.7 μF, max.
Annunciator port (RS-485)
Performance class Class B and Redundant Class B
Baud rate 9600 and 38400
Two cables connect the Wire type Twisted pair, 6 twists per foot, min.
PS10-4B Power Supply Circuit length 4,000 ft. (1,219 m)
PS10-4B Circuit resistance 90 Ω, max.
Power
to the back of the SFS1-
supply CPU main board. Circuit capacitance 0.3 μF, max.
Signaling line circuit
Quantity 2 (second SLC requires optional 3-SDC1 card)
SFS1-CPU
Main Board Performance class Class A, Class X, or Class B
Circuit capacity 125 detectors, 125 single address modules
Circuit resistance 100 Ω, max.
Circuit capacitance 0.5 μF, max.
Wire size 18 to 12 AWG (0.75 mm² to 2.50 mm²)
Ground fault
10 kΩ
The 4X-LCD as- impedance
sembly mounts to Operating environment
hinge pins on the Temperature 32 to 120°F (0 to 49°C)
CPU and connects Relative humidity 0 to 93% noncondensing
with a single ribbon Notes
cable. • For battery calculations, standby and alarm currents include all listed primary
power supplies.
4X-LCD SFS1-CPU • The common trouble relay operation does not include AC trouble delay
User Interface Main Board
functionality and cannot be used for reporting troubles off premises per UL
864 10th edition.

Page 4 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
PS10-4B Power 3-SDC1 Signature Standard

Supply Card Data Circuit Card SDC1 card


for SLC1

The PS10-4B Power Supply Card provides the Each 3-SDC1 Signature Data Optional
required power and related supervision functions Circuit Card provides one Class SDC1 card
for SLC2
for the control panel, as well as filtered, regulated A or Class B signaling line circuit
power to the rail chassis modules. It also provides (SLC1) that supports up to 125
24 VDC for operating ancillary equipment. Signature Series detectors and
SFS1-CPU
125 Signature Series module Main Board
PS10-4B Specifications addresses. These modules also
Mains voltage 94 to 264 VAC, 50/60 Hz provide connection for powering conventional two-wire smoke
AC Input Current detector circuits on Signature Series modules.
Standby 1.5 amps
EST3X comes standard with one 3-SDC1 card installed as SLC1.
Alarm 3.0 amps
An optional second 3-SDC1 card may be installed to provide
Brownout level 93 VRMS
SLC2, thus doubling system signaling line capacity.
Battery charging capacity 65 Ah max.
Total Power Voltage 24vdc 3-SDC1 Specifications
Standby Current 88mA
Alarm Current 169mA Voltage 24 VDC
Supply Ratings Current 10 amps (UL), 9.0amps (ULC) Operating current with fully loaded loop
Notification appliance/Auxiliary power circuits  Standby 3-SSDC1 144 mA; 3-SDDC1 264 mA
UL rating  Alarm 3-SSDC1 204 mA; 3-SDDC1 336 mA
Quantity 4 Smoke power 19.95 VDC max.1
Circuit configuration Class B1 Circuit
Output voltage Special: 24 Vdc Configuration Class B, Class A, or Class X
Regulated: 24 Vdc Capacity 125 Signature Series detectors and 125
Output current Special: 3 amps Signature Series modules per SLC
Regulated: 1.5 amps Resistance 100 Ω with 250 devices
EOLR 15 kΩ (UL P/N EOL-15, ULC P/N EOL-P1) Capacitance 0.5 μF max.
Wiring Wire size 12 AWG (1.5 mm²) max.
Mains input 2 Supervised, non power-limited Termination Removable plug-in terminal strips on the SFS1-CPU
Battery input Supervised, non power-limited main board and Signature module
NAC outputs Supervised, power-limited Operating environment
Wire size 18 to 12 AWG (0.75 mm² to 2.50 mm²) Temperature 32 to 120 °F (0 to 49 °C)
Ground fault impedance 10 kΩ Relative humidity 0 to 93% noncondensing
Operating environment For special applications, refer to EST3 ULI/ULC Compatibility Lists (P/N 3100427)
1

Temperature 32 to 120 °F (0 to 49 °C)


Relative humidity 0 to 93% noncondensing
Class A when a CLA-PS10 Class A adapter card is installed.
1

Connect the mains supply using a dedicated branch.


2

4X-LCD SFS1 LED Control/


User Interface Display Module SFS1
LED Rail
Included in the EST3X basic package, the 4X- The SFS1 LED Control/Display Module Control/ Module
LCD provides the user interface for the EST3X provides additional operator interface Display
Module
system. It connects to the SFS1-CPU main capability for the SFS1 system. It can
board with a ribbon cable, and attaches to be mounted on any of the three right-
the CPU via hinges. Only one display module most local rail modules on the 3-SFS1
is required to provide a point of control for electronics chassis. Inserts are provided
the entire network. Additional displays can be for labeling switches and LEDs.
added to any EST3X panel in the network to
provide additional points of control. SFS1 Specifications
Voltage 24 VDC
4X-LCD Specifications Operating current
Operating current Standby 2.0 mA plus 1.5 mA for each active LED
Standby 55mA Alarm 2.0 mA plus 1.5 mA for each active LED
Alarm 66mA Operating environment
Backlit liquid crystal display 240 x 320 pixels Temperature 32 to 120 °F (0 to 49 °C)
LCD display
24 lines of 40 characters Relative humidity 0 to 93% noncondensing
Operating environment
Temperature 32 to 120 °F (0 to 49 °C)
Relative humidity 0 to 93% noncondensing

Page 5 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
3X-FIB fiber optic 3X-FIB8 fiber optic
network module SFS1-CPU
Main Board network module SFS1-CPU
Main Board

The 3X-FIB fiber optic network module The 3X-FIB8 fiber optic network mod-
gives an EST3X panel the ability to net- ule gives an EST3X panel the ability to
work 64 EST3X panels, or interface with network up to eight EST3X nodes. Class
an EST3 network. Class A, Class X and A, Class X and Class B connections are
Class B connections are supported. The supported. The module consists of the
3X-FIB8 3X-FIB
module consists of the adapter card and adapter
adapter card and electronics card. adapter
electronics card. card card
The 3-FIB8 supports the following fiber
The 3X-FIB supports the following fiber optic transceivers: optic transceivers:
Model Description Model Description
SMXLO2 Standard output single mode fiber optic transceiver SMXLO2 Standard output single mode fiber optic transceiver
SMXHI2 High output single mode fiber optic transceiver SMXHI2 High output single mode fiber optic transceiver
MMXVR Standard output multimode fiber optic transceiver MMXVR Standard output multimode fiber optic transceiver

The 3X-FIB provides terminals for connecting a 24 VDC backup The 3X-FIB8 provides terminals for connecting a 24 VDC backup
power source to maintain data transmissions in the event the power source to maintain data transmissions in the event the
panel is powered down. panel is powered down.
Note: All networked panels must have the 3X-FIB network card installed. Note: All networked panels must have the 3X-FIB8 network card installed.

3X-FIB Specifications 3X-FIB8 Specifications


Voltage 19.2 to 27.6 VDC (24 VDC nominal) Voltage 19.2 to 27.6 VDC (24 VDC nominal)
Fiber optics network and audio Fiber optics network and audio
 Budget  Budget
 SMXLO2 15 dBm between two interfaces  SMXLO2 15 dBm between two interfaces
 SMXHI2 25 dBm max. and 8 dBm min. 10 dBm  SMXHI2 25 dBm max. and 8 dBm min. 10 dBm
between two interfaces between two interfaces
 MMXVR 50/125, 62.5/125, or 100/140 for MMXVR  MMXVR 50/125, 62.5/125, or 100/140 for MMXVR
Cable type Cable type
Connectors 50/125, 62.5/125, or 100/140 for Connectors 50/125, 62.5/125, or 100/140 for
SMXLO2, SMXHI2 Type Duplex SC SMXLO2, SMXHI2 Type Duplex SC
MMXVR Type ST MMXVR Type ST
Network data circuit Network data circuit
Circuit configuration Class B, Class A or Class X Circuit configuration Class B, Class A or Class X
Data rate 19.2 K, 38.4 kbps Data rate 19.2 K, 38.4 kbps
Isolation Isolated from previous panel CPU when using Isolation Isolated from previous panel CPU when using
copper. Total isolation when using fiber optics. copper. Total isolation when using fiber optics.
Digitized audio data circuit Digitized audio data circuit
Circuit configuration Class B, Class A or Class X Circuit configuration Class B, Class A or Class X
Data rate 327 kbps Data rate 327 kbps
Isolation Isolated from previous panel CPU when using Isolation Isolated from previous panel CPU when using
copper. Total isolation when using fiber optics. copper. Total isolation when using fiber optics.
Copper wired network data circuit segment Copper wired network data circuit segment
 Circuit  Circuit
Length 5,000 ft. (1,524 m) max. between any three Length 5,000 ft. (1,524 m) max. between any three
panels panels
Resistance 90 Ω max. Resistance 90 Ω max.
Capacitance 0.3 µF max.1 Capacitance 0.3 µF max.1
Wire type Twisted Pair, 18 AWG (0.75 mm²) min. Wire type Twisted Pair, 18 AWG (0.75 mm²) min.
Operating environment Copper wired audio data circuit
Temperature 32 to 120 °F (0 to 49 °C) Circuit
Relative humidity 0 to 93% noncondensing Length 5,000 ft. (1,524 m) max. between any three
1
Include shield capacitance, if shielding is used. panels
Resistance 90 Ω max.
Capacitance 0.09 μF, max1
Wire type Twisted pair, 18 AWG (0.75 mm²) min.
Operating environment
Temperature 32 to 120 °F (0 to 49 °C)
Relative humidity 0 to 93% noncondensing
1
Include shield capacitance, if shielding is used.

Page 6 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
3X-NET Network 3X-ETH Ethernet
Adapter Card SFS1-CPU
Adapter Cards SFS1-CPU
Main Board
The 3X-NET network adapter card gives Main Board Three optional Ethernet adapter cards
an SFS1-CPU main board the ability to are available for EST3X applications.
network up to 64 nodes on an EST3 Each of these provide specific features
network. The card supports Class B, such as panel programming, diagnostics,
Class A, and Class X wiring. and status monitoring, as well as central 3X-ETH
3X-NET
card station connectivity, and email or email- card
The 3X-NET adapter card provides two
to-text messaging capability.
independent RS 485 circuits: one for network data communica-
tions and one for digital audio communications. Supported communications ETH1 ETH2 ETH3
CU communications with the Panel for
• • •
3X-NET Specifications Programming and Diagnostic Functions
Voltage 24 VDC FireWorks (ECP/IP) Gateway Communications • • •
Operating Current IP Dialer Communications • •
Standby 98 mA at 24 VDC Email and Text Communications •
Alarm 98 mA at 24 VDC
Each EST3X control panel supports up to eight IP services, which can provide con-
Circuit configuration nection to any combination of the following functions:
Network data Class A, Class X, or Class B Programming
Network audio Class A, Class X, or Class B FireWorks Graphical User Interfaces
IP Dialer (IP-DACT)
Isolation
Email
Network data Network A port not isolated; Network B port isolated
Network audio Audio A IN and Audio B IN isolated Each EST3X network supports up to:
10 ECP Connections, and;
Audio A OUT and Audio B OUT not isolated 100 Dialer Accounts, and;
Wire size Twisted pair1 18 AWG (0.75 mm) min. 100 Email Accounts (up to 20 email addresses per account).
Circuit length 5,000 ft. (1,524 m) between any three panels
Circuit resistance 90 Ω max.
Circuit capacitance Data: 0.3 μF max.; Audio 0.09 μF max. 3X-ETH1, 3X-ETH2, 3X-ETH3 Specifications
Operating environment See Ordering Information for adapter card functional descriptions
Temperature 32 to 120 °F (0 to 49 °C)
Ethernet 10/100 Base-T
Relative humidity 0 to 93% noncondensing
Voltage 24 VDC
Six twists per foot minimum
1

Operating current
Standby 42 mA at 24 VDC
Active 42 mA at 24 VDC
Connection mode Auto negotiation
3X-NET8 Wire runs
network card SFS1-CPU
Main Board Distance 200 ft. (60 m) max.1
Type Cat 5
The 3X-NET8 RS-485 network card
Connector RJ-45
gives an SFS1-CPU main board the
Operating environment
ability to network through dedicated
Temperature 32 to 120 °F (0 to 49 °C)
copper wire up to eight EST3X control
Relative humidity 0 to 93% noncondensing
panels. The card supports Class B, 3X-NET8
card Panel to communication equipment
1
Class A, or Class X wiring.
Note: All networked panels must have a 3X-NET8 network card installed.

3X-NET8 Specifications
Voltage 24 VDC
Operating Current
 Standby 98 mA at 24 VDC
 Alarm 98 mA at 24 VDC
Circuit configuration
Network data Class A, Class X, and Class B
Isolation
  Network data Network A port not isolated, Network B port isolated
Wire size Twisted pair1 18 AWG (0.75 mm) min.
Circuit length 5,000 ft. (1,524 m) between any three panels
Circuit resistance 90 Ω max.
Circuit
0.3 μF max.
capacitance
Operating
environment
32 to 120 °F (0 to 49 °C)
Temperature
0 to 93% noncondensing
Relative humidity
1
Six twists per foot min.

Page 7 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
3X-PMI Paging CLA-PS10 Class A
Microphone Interface Adapter Card
PS10-4B
Power
supply
The 3X-PMI Paging Microphone The CLA-PS10 Class A Adapter Card is
Interface provides controls for an optional card used to convert the four
emergency voice/alarm communica- Class B notification appliance/auxiliary
tions. It consists of an audio mount- power circuits on the power supply card to
ing bracket, EAEC Emergency Audio Class A.
Evacuation Controller card, audio CLA-PS10 Class A
enclosure, and paging microphone. CLA-PS10 Specifications Adapter Card

Voltage 24 VDC
3X-PMI Paging Microphone Interface Specifications Notification appliance/Auxiliary power circuits
Voltage 24 VDC UL rating Special application or Regulated
Current Quantity 4
Standby 23mA Performance class Class A
Alarm 29mA Output current Special 3.0 A; Regulated: 1.5 A each circuit
Ground fault impedance 10 kΩ EOLR 15 kΩ (UL P/N EOL-15, ULC P/N EOL-P1)
Wire size 18 to 12 AWG (0.75 to 2.50 mm²) Wiring Supervised, power-limited
Audio channels 8 simultaneous Wire size 18 to 12 AWG (0.75 mm² to 2.50 mm²)
Audio inputs Operating environment
Local microphone Isolated and supervised Temperature 32 to 120 °F (0 to 49 °C)
Remote microphone Isolated and supervised Relative humidity 0 to 93% noncondensing
Remote audio Isolated and supervised
EAEC communication See the EAEC Emergency Audio
Evacuation Control Installation Sheet
(P/N 3101789)
Messages
Storage 2 min. total
Length 39 sec. max.
Controls and indicators
Common
Paging Volume Indicates relative signal strength during
active page
Ready To Page Flashes during preannouncement
Paging Microphone tone, steady when ready to page
All Call Activates/deactivates page to all areas
All Call Minus Activates/deactivates page to areas
not receiving EVAC or Alert message
Page To Evac Activates/deactivates page to areas
currently receiving the EVAC message
Page To Alert Activates/deactivates page to areas
currently receiving the Alert message
Operating environment
Temperature 32 to 120°F (0 to 49°C)
Relative humidity 0 to 93% noncondensing

SFS1-CPU
NETWORKA UDIO AUDIOA UDIO AUDIO R C AB
OUT IN A IN A OUT B IN B OUT R T T O RS-485 RS-485
AA BB X X S M BUSB US
+- +- +- +- +- +- 1 1 1 1 -+ + -

Network Network
option card option card
installed not installed

KEY_OUT
Remote
AUDIO_OUT microphone

SHIELD
MN-PASM2 UL 864 and
UL 2572 listed
MN-FVPN equipment with
compatible
ratings

EAEC KEYA UDIO AUX OUTA UX IN


AUDIO
DATA REMOTE MIC

Page 8 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
Ordering Information
Intelligent Analog Control Panels
Model Door Color Language Description
3X-SFS1B Bronze FACP, complete system with user interface, CPU, one loop with second loop expansion, three option card
English
3X-SFS1R Red slots, four Class B NAC, universal 110/220v 10 amp power supply. Order 3-SDC1 for second loop.
3X-SFS1Bi Bronze
Selectable
3X-SFS1Ri Red
TRIM6 Flush trim ring

Network communication option cards


3X-NET8 RS485, eight node max. Class A, X or B network. Use on 3-SFS systems only.
3X-NET RS485, eight node max. Class A, X or B network. Use on 3-SFS systems only.
3X-FIB8 Fiber, 8 node max. Uses MMXVR, SMXHI2, SMXLO2. Use on 3-SFS systems only.
3X-FIB Fiber motherboard for connection to EST3 systems. Used with MMXVR, SMXHI2 and SMXLO2.
SMXLO2 Standard output single mode fiber optic transceiver
SMXHI2 High output single mode fiber optic transceiver
MMXVR Standard output multimode fiber optic transceiver

Communication Options (See 3X-ETH installation sheet P/N 3101794-EN for details on wiring specific applications.)
3X-ETH1 Ethernet Adapter, 10/100. Provides Ethernet connection from system to 3-SDU for remote programming and diagnostics, and to
FireWorks computer graphics workstation.
3X-ETH2 Ethernet Adapter, 10/100. Provides the functions of ETH1 plus IP for central station communications.
3X-ETH3 Ethernet adapter card. Provides the functions of the 3X-ETH2 plus the added capability of sending email messages as well as SMS
text messages by means of email-to-text.

Front Panel LED/Switch display modules


4X-12/S1GY LED Display/Control Module - 12 Switches, 1 Green, 1 YELLOW LED per switch.
4X-12/S1RY LED Display/Control Module - 12 Switches, 1 RED, 1 YELLOW LED per switch.
4X-12SR LED Display/Control Module - 12 Switches with 12 RED LEDs.
4X-12RY LED Display Module - 12 pairs of LEDs (1 Red; 1 Yellow)
4X-24Y LED Display Module - 24 YELLOW
4X-24R LED Display Module - 24 RED
4X-6/3S1G2Y LED/Switch Module - six groups of three Switches with one LED each.
4X-6/3S1GYR LED/Switch Module - six groups of three Switches with one LED each.
4X-4/3SGYWR LED/Switch Module, four groups of three switches and four LEDs. LED colors: Green, Red, Yellow and White.
4X-LKF Label Kit, French

Option Cards and Interfaces


3X-PMI Paging Microphone Interface. See Note 1.
3-SSDC1 Single Signature Driver Controller, c/w one 3-SDC1
3-SDDC1 Dual Signature Driver Controller, c/w two 3-SDC1s
3-SDC1 Signature Device Card - expands the 3X base panel to two loops
3-SDC1-HC 3-SDC1-HC used with circuits that contain more than 90 isolators.
3-ZA20A 20 Watt Zoned Amplifier w/Class A/B Audio & Class A/B 24 VDC outputs
3-ZA20B 20 Watt Zoned Amplifier w/Class B Audio & Class B 24 VDC outputs
3-ZA40A 40 Watt Zoned Amplifier w/Class A/B Audio & Class A/B 24 VDC outputs
3-ZA40B 40 Watt Zoned Amplifier w/Class B Audio & Class B 24 VDC outputs
3-MODCOM Modem/Dialer (DACT)
3-AADC1 Addressable Analog Module
3-IDC8/4 Initiating Device Circuit Module
3-LDSM LED Display Support Module. Provides interface for one LED/Switch display module.
Mounts in an option card slot where no Option cards are installed.
3-OPS Off Premises Signaling module
CLA-PS10 Class A Adapter, PS10 NACs
CDR-3 PSNI Coder Module
GCI Graphic Annunciator Driver Master, provides outputs for 32 LEDs and connection to common control switches and LEDs for
R-Series annunciators.
GCIX Graphic Annunciator Driver Expander, provides outputs for 48 LEDs and inputs for 24 switches.
Note 1: For ULC 11th edition multiple command center applications add MCC to the PMI SKUs as shown, (3X-PMIMCC, 3X-PMIMCC-FR).

Page 9 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
Accessories
PS10-4B Power Supply, Replacement
SFS1-ELEC Base Electronics, replacement
4X-LCD Main user interface assembly, monochrome. Eight line 1/4 VGA LCD, four controls
plus rotary knob. English language.
L I F E S A F E TY & I NCI DE NT M AN AGEM EN T
4X-LCD-LC Main user interface assembly, monochrome. Eight Line 1/4 VGA LCD, four controls
Contact us... plus Rotary knob. Insertable language, shipped with English inserts. Order alternate
Email: [email protected] languages separately.
Web: edwards-fire.com 4X-DR Blank hinged local rail module door
1016 Corporate Park Drive
4X-CAB6D Replacement door, bronze
Mebane, NC 27302 4X-CAB6DR Replacement door, red
CAB6B Backbox, black
EDWARDS is a registered mark in the
United States and other countries. CAB6BEQ Seismic hardening Kit for batteries up to 17Ah.
Note: For earthquake anchorage, including detailed mounting weights and center of gravity detail, please refer
© 2018 United Technologies Corporation. to Seismic Application Guide 3101676-EN. Approval of panel anchorage to site structure may require local AHJ,
All rights reserved. structural, or civil engineer review.

Firmado electrónicamente por:

JUAN PABLO
CORREA

12-20-17

Page 10 of 10 D ATA S H E E T E85005-0133


Not to be used for installation purposes. Issue 1.2
EDWARDS Catalog u Intelligent Input/Output

LIFE SAFETY & INCIDENT MANAGEMENT

Signal Modules
SIGA-CC1, SIGA-MCC1,
SIGA-CC2 & SIGA-MCC2

SIGA-CC

SIGA-MCC

MEA 7300-1657:
0121 S3424

Overview Standard Features


SIGA-CC1/MCC1 Single Input Signal Modules and SIGA-CC2/ • Single and Dual input (riser) select
MCC2 Dual Input Signal Modules are part of EDWARDS's Signa- Use for connecting supervised 24 Vdc Audible/Visible signal
ture Series system. They are intelligent analog addressable devic- circuits, or 25 and 70 VRMS Audio Evacuation and Telephone
es used for connecting, upon command from the loop controller, circuits to their power inputs.
supervised Class B signal or telephone circuits to their respective
• Ring-tone generator
power inputs. The power inputs may be polarized 24 Vdc to oper-
When configured for telephone circuits, the SIGA-CC1 gener-
ate audible and visible signal appliances or 25 and 70 VRMS to
ates its own ring-tone signal eliminating the need for a separate
operate audio evacuation speakers and firefighter’s telephones.
ring-tone circuit.
The actual operation of the SIGA-CC1/MCC1 and SIGA-CC2/ • Plug-in (UIO) or standard 2-gang mount
MCC2 is determined by the “personality code” selected by the UIO versions allow quick installation where multiple modules
installer. It is downloaded to the module from the Signature loop are required. The 2-gang mount version is ideal for remote
controller during system configuration. locations that require a single module.
The SIGA-CC1 and SIGA-CC2 mount to standard North Ameri- • Automatic device mapping
can two-gang electrical boxes, making them ideal for locations Signature modules transmit information to the loop controller
where only one module is required. Separate I/O and data loop regarding their circuit locations with respect to other Signature
connections are made to each module. devices on the wire loop.
The SIGA-MCC1 and SIGA-MCC2 are part of the UIO family of • Electronic addressing
plug-in Signature Series modules. They function identically to the Programmable addresses are downloaded from the loop con-
SIGA-CC1 and SIGA-CC2, but take advantage of the modular troller, a PC, or the SIGA-PRO Signature Program/Service Tool;
flexibility and easy installation that characterize all UIO modules. there are no switches or dials to set.
Two- and six-module UIO motherboards are available. These can
accommodate individual risers for each on-board module, or risers • Intelligent device with microprocessor
that are shared by any combination of its UIO modules. All wiring All decisions are made at the module to allow lower com-
connections are made to terminal blocks on the motherboard. UIO munication speed with substantially improved control panel
assemblies may be mounted in EDWARDS enclosures. response time and less sensitivity to line noise and loop wiring
properties; twisted or shielded wire is not required.
• Ground fault detection by address
Detects ground faults right down to the device level.

Page 1 of 6 D ATA S H E E T E85001-0237


Not to be used for installation purposes. Issue 1
Installation Application
The SIGA-CC1 and SIGA-CC2: mount to North American The operation of the SIGA-CC1/MCC1 and SIGA-CC2/MCC2
2-1/2 inch (64 mm) deep two-gang boxes and 1-1/2 inch (38 mm) is determined by their sub-type code or “Personality Code”. The
deep 4-inch square boxes with two-gang covers and SIGA-MP code is selected by the installer depending upon the desired ap-
mounting plates. The terminals are suited for #12 to #18 AWG (2.5 plication and is down-loaded from the loop controller. Codes 5 and
mm2 to 0.75 mm2) wire size. 6 apply to the SIGA-CC1/MCC1 only. Code 7 is assigned to the
SIGA-CC2/MCC2 only and automatically applies to both circuits (A
and B).
Personality Code 5: SIGNAL POWER or AUDIO EVACU-
ATION (SINGLE RISER). Valid for the SIGA-CC1/MCC1 only.
Configures the module for use as a Class B Audible/Visible Signal
power (24 Vdc polarized) or Audio Evacuation (25 or 70 VRMS)
power selector. The ring-tone generator is disabled. The output
circuit is monitored for open or shorted wiring. If a short exists,
the control panel inhibits the activation of the audible/visible signal
circuit to prevent connection to the power circuit.
Personality Code 6: TELEPHONE w/RING-TONE (SINGLE
RISER). Valid for the SIGA-CC1/MCC1 only. Configures the
module for use as a Telephone power selector. When a telephone
handset is plugged into its jack or lifted from its hook, the module
generates its own Ring-Tone signal. A separate ring-tone circuit is
not needed. The module sends this signal to the control panel to
SIGA-MCC1 and SIGA-MCC2: mount the UIO motherboard indicate that an off-hook condition is present. When the system
inside a suitable EDWARDS enclosure with screws and washers operator responds to the call, the ring-tone signal is disabled.
provided. Plug the SIGA-MCC1 or SIGA-MCC2 into any available
Personality Code 7: SIGNAL POWER or AUDIO EVACUA-
position on the motherboard and secure the module to the moth-
TION (DUAL RISER). Valid for the SIGA-CC2/MCC2 only. Con-
erboard with the captive screws. Wiring connections are made
figures the module for use as a two circuit Class B Audible/Visible
to the terminals on the motherboard (see wiring diagram). UIO
Signal power (24 Vdc polarized) or Audio Evacuation (25 or 70
motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to
VRMS) power selector. The single output circuit is monitored for
open or shorted wiring. If a short exists, the control panel inhibits
UIO Motherboard
the activation of the audible/visible signal circuit to prevent con-
6-32 nection to the power circuit.
Self-tapping
screws

Warnings & Cautions


Plug-in (UIO) Captive
Module screws This module will not operate without electrical power. As fires fre-
quently cause power interruption, we suggest you discuss further
safeguards with your fire protection specialist.
#6 Flat washers

Cabinet or electrical enclosure


Compatibility
The Signature Series modules are compatible only with ED-
0.75 mm2) wire size. WARDS's Signature Loop Controller.
EDWARDS recommends that this module be installed according
to latest recognized edition of national and local fire alarm codes.
Testing & Maintenance
Electronic Addressing - The loop controller electronically ad-
The module’s automatic self-diagnosis identifies when it is defec-
dresses each module saving valuable time during system com-
tive and causes a trouble message. The user-friendly maintenance
missioning. Setting complicated switches or dials is not required.
program shows the current state of each module and other perti-
Each module has its own unique serial number stored in its on-
nent messages. Single modules may be turned off (de-activated)
board memory. The loop controller identifies each device on the
temporarily, from the control panel.
loop and assigns a “soft” address to each serial number. If desired,
the modules can be addressed using the SIGA-PRO Signature Scheduled maintenance (Regular or Selected) for proper system
Program/Service Tool. operation should be planned to meet the requirements of the
Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and
Personality Codes 5 and 6 apply to the SIGA-CC1/MCC1 only and
ULC CAN/ULC 536 standards.
are assigned by the installer. Code 7 applies to the SIGA-CC2/
MCC2 only. It is factory assigned; no user configuration is required.

Page 2 of 6 D ATA S H E E T E85001-0237


Not to be used for installation purposes. Issue 1
Typical Wiring (SIGA-CC2/MCC2)
Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5mm2) wire sizes.
Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog
sheet for detailed wiring requirement specifications.

Typical Speaker Circuit


Personality
Code 7 UL/ULC Listed
47K EOL

Personality Typical Notification Appliance Circuit


Bi-polar Transient Protector Code 7
(P/N 235196P) + + + + + +
UL/ULC Listed
_ _ _ _ _ _ 47K EOL

Personality Typical Speaker Circuit


Code 7
UL/ULC Listed
47K EOL

Personality Typical Notification Appliance Circuit


SIGA-CC2 Code 7
+ + + + + +
Bi-polar Transient Protector UL/ULC Listed
(P/N 235196P) _ _ _ _ _ _ 47K EOL

1 2
Notes UIO(R) series motherboard
4 8

1 For maximum wire resistance and maximum wire dis- 1 23 4 MCC2


tances, refer to IOMC Manual (P/N 270144).
8 9
2 Maximum #12 AWG (2.5mm2) wire. Min. #18 (0.75mm2).

7 3
4
Data In 3 Riser 1 Out

3 Refer to Signature Loop Controller Installation Sheet for


2
1 Riser 1 In
Signature 4
wiring specifications. Data
3
2
TB14
Circuit 1
4 These modules will NOT support two-wire smoke detec-
473387353

TB7

tors.
CAT NO.

8 9
MCC2

Data Out
4
3 Riser 2 Out
5 All wiring power limited and supervised. If the input 2
1 Riser 2 In
source is non-power limited, then maintain spacing of Green LED (Normal) TB15

1/4 inch or use FPL, FPLP, FPLR or equivalent in accord- Red LED (Active)
UIOR series motherboard individual
ance with NEC. 8 Riser 1 connection. Install the
jumpers between adjacent modules
1 23 4 that use the same riser.
6 The SIGA-UIO6 does not come with TB8 through TB13.
Riser 1 In Riser 1 Out

7 Supervised and power-limited.


8 Supervised and power-limited when connected to a SIGA-MCC2
power-limited source. If the source is nonpower-limited,
maintain a space of 1/4 inch from power-limited wiring Maximum Output Load
or use FPL, FPLP, FPLR, or an equivalent in accordance
24Vdc 25V 70V
with the National Electrical Code.
Signals Audio Audio
9 The input for this riser is common to all modules.
2A 50W 35W

Page 3 of 6 D ATA S H E E T E85001-0237


Not to be used for installation purposes. Issue 1
Typical Wiring (SIGA-CC1/MCC1)
Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 (2.5mm2) wire sizes.
Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog
sheet for detailed wiring requirement specifications.

Personality Typical Speaker Circuit


Code 5
UL/ULC Listed
47K EOL

Personality Typical Telephone Circuit


Code 6 Maximum Output Load
UL/ULC Listed 24Vdc 25V 70V
47K EOL
Signals Audio Audio
2A 50W 35W
Personality Typical Notification Appliance Circuit
Code 5
+ + + + + +
UL/ULC Listed
_ _ _ _ _ _ 47K EOL

Install the Bi-Polar Transient Protector (P/N 235196P) here.


4 5

Personality Typical Speaker Circuit


Code 5
UL/ULC Listed
47K EOL

Personality Typical Telephone Circuit


Code 6
UL/ULC Listed
47K EOL

SIGA-CC1 Personality Typical Notification Appliance Circuit


Code 5
+ + + + + +
Notes UL/ULC Listed
_ _ _ _ _ _ 47K EOL

2 Maximum #12 AWG (2.5mm ) wire. Min. #18 (0.75mm ).
2 2

Install the Bi-Polar Transient Protector (P/N 235196P) here.


3 Refer to Signature Loop Controller Installation Sheet 1 2 4 5
for wiring specifications. 1 23 4
MCC1
UIO(R) series motherboard
4 These modules will NOT support two-wire smoke
detectors. Data In 7 3 4
3 Riser 1 Out
5 All wiring power limited and supervised. If the input 2
1 Riser 1 In
Signature 4
source is non-power limited, then maintain spacing Data 3 TB14
2
of 1/4 inch or use FPL, FPLP, FPLR or equivalent in Circuit
1
5 8 9

accordance with NEC.


473387352

TB7
CAT NO.
MCC1

Data Out
6 The SIGA-UIO6 does not come with TB8 through 4 No connections required for
TB13. 3
2 MCC1. Other modules may
1 require connections.
7 Supervised and power-limited. Green LED (Normal)
Red LED (Active)
TB15
UIOR series motherboard individual
8 If the source is nonpower-limited, maintain a space of 1 23 4 Riser 1 connection. Install the
1/4 inch from power-limited wiring or use FPL, FPLP, 6 8 jumpers between adjacent
modules that use the same riser.
FPLR, or an equivalent in accordance with the National Riser 1 In Riser 1 Out
Electrical Code.
SIGA-MCC1
9 The input for this riser is common to all modules.

Page 4 of 6 D ATA S H E E T E85001-0237


Not to be used for installation purposes. Issue 1
Signature Series Overview
The Signature Series intelligent analog-addressable system from Automatic Device Mapping –The Signature Data Control-
EDWARDS is an entire family of multi-sensor detectors and ler (SDC) learns where each device’s serial number address is
mounting bases, multiple-function input and output modules, net- installed relative to other devices on the circuit. The SDC keeps a
work and non-network control panels, and user-friendly mainte- map of all Signature Series devices connected to it. The Signature
nance and service tools. Analog information from equipment con- Series Data Entry Program also uses the mapping feature. With
nected to Signature devices is gathered and converted into digital interactive menus and graphic support, the wired circuits between
signals. An onboard microprocessor in each Signature device each device can be examined. Layout or “as-built” drawing
measures and analyzes the signal and decides whether or not to information showing branch wiring (T-taps), device types and their
input an alarm. The microprocessor in each Signature device pro- address are stored on disk for printing hard copy. This takes the
vides four additional benefits – Self-diagnostics and History Log, mystery out of the installation. The preparation of as-built drawings
Automatic Device Mapping, and Fast, Stable Communication. is fast and efficient.
Self-diagnostics and History Log – Each Signature Series Device mapping allows the Signature Data Controller to discover:
device constantly runs self-checks to provide important mainte- • Unexpected additional device addresses
nance information. The results of the self-check are automatically
• Missing device addresses
updated and permanently stored in its non-volatile memory. This
information is accessible for review any time at the control panel, • Changes to the wiring in the circuit.
PC, or using the SIGA-PRO Signature Program/Service Tool. The Most Signature modules use a personality code selected by the
information stored in device memory includes: installer to determine their actual function. Personality codes are
• Device serial number, address, and type downloaded from the SDC during system configuration and are
• Time and date of last alarm (EST3 V 2 only.) indicated during device mapping.
• Most recent trouble code logged by the detector — 32 possible
trouble codes may be used to diagnose faults.

Page 5 of 6 D ATA S H E E T E85001-0237


Not to be used for installation purposes. Issue 1
Specifications
Catalog Num-
SIGA-CC1 SIGA-MCC1 SIGA-CC2 SIGA-MCC2
ber
Description Single Input (Riser) Signal Module Dual Input (Riser) Signal Module
L I F E S A F E TY & I NCI DE NT M AN AGEM EN T
51 (factory set) One sub-type
50 (factory set) Two sub-types
Type Code (personality code) is available (factory
(personality codes) are available
Contact us... set)
Email: [email protected] Address Require-
Uses one module address Uses two module addresses
Web: Edwards-fire.com ments
Wiring Termina-
Suitable for #12 to #18 AWG (2.5 mm² to 0.75mm²)
EDWARDS is a UTC brand.
tions
1016 Corporate Park Drive North American
North American
Mebane, NC 27302 2½ inch (64 mm)
2½ inch (64 mm)
deep two-gang
deep two-gang
© 2016 United Technologies Corporation. boxes and 1½
boxes and 1½
All rights reserved. inch (38 mm) Plugs into UIO2R, Plugs into UIO2R,
inch (38 mm)
Mounting deep 4 inch UIO6R or UIO6 UIO6R or UIO6
deep 4 inch
square boxes Motherboards Motherboards
square boxes
with 2-gang cov-
with 2-gang cov-
ers and SIGA-
ers and SIGA-MP
MP mounting
mounting plates
plates
Operating Current Standby = 223µA Activated = 100µA
Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal)
Output Rating 24 Vdc = 2 amps 25 V Audio = 50 watts 70 V Audio = 35 watts
Construction High Impact Engineering Polymer
Storage & Oper- Operating Temperature: 32°F to 120°F (0°C to 49°C)
ating Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH
On-board Green LED - Flashes when polled On-board Red LED - Flashes
LED Operation
when in alarm/active
Compatibility Use with: Signature Loop Controller
Agency Listings UL, ULC, CSFM, MEA, FM

Ordering Information
Catalog Ship Wt.
Description
Number lbs (kg)
SIGA-CC1 Single Input Signal Module (Standard Mount) - UL/ULC Listed 0.5 (0.23)
SIGA-MCC1 Single Input Signal Module (UIO Mount) - UL/ULC Listed 0.18 (0.08)
SIGA-CC2 Dual Input Signal Module (Standard Mount) - UL/ULC Listed 0.5 (0.23)
SIGA-MCC2 Dual Input Signal Module (UIO Mount) - UL/ULC Listed 0.18 (0.08)

Related Equipment
27193-21 Surface Mount Box - Red, 2-gang 2 (1.2)
27193-26 Surface Mount Box - White, 2-gang 2 (1.2)
Universal Input-Output Module Board w/Riser Inputs - Two Module
SIGA-UIO2R 0.32 (0.15)
Positions
Universal Input-Output Module Board w/Riser Inputs - Six Module
SIGA-UIO6R 0.62 (0.28)
Positions
SIGA-UIO6 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25)
235196P Bi-polar Transient Protector 0.01 (0.05)

Accessories
Multifunction Fire Cabinet - Red, supports Signature
Firmado electrónicamente por: MFC-A 7.0 (3.1)
JUAN PABLO Module Mounting Plates
CORREA SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70)
SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23)
SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46)
10-11-16

Page 6 of 6 D ATA S H E E T E85001-0237


Not to be used for installation purposes. Issue 1
EDWARDS Catalog u Intelligent Input-Output

LIFE SAFETY & INCIDENT MANAGEMENT

Input Modules
SIGA-CT1, SIGA-CT1HT,
SIGA-CT2, SIGA-MCT2

SIGA-CT1/2

SIGA-MCT2

MEA
7300-1657:
0121 S3424

Overview Standard Features


The SIGA-CT1 Single Input Module, SIGA-CT1HT High Tem- • Multiple applications
perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Including Alarm, Alarm with delayed latching (retard) for water-
Input Modules are intelligent analog addressable devices used to flow applications, Supervisory, and Monitor. The installer selects
connect one or two Class B normally-open Alarm, Supervisory, or one of four “personality codes” to be downloaded to the mod-
Monitor type dry contact Initiating Device Circuits (IDC). ule through the loop controller.
The actual function of these modules is determined by the “personal- • SIGA-CT1HT rated for high temperature environments
ity code” selected by the installer. This code is downloaded to the Suitable for attic installation and monitoring high temperature
module from the Signature loop controller during system configura- heat detectors.
tion. • Plug-in (UIO) or standard 1-gang mount
UIO versions allow quick installation where multiple modules are
The input modules gather analog information from the initiating
required. The 1-gang mount version is ideal for remote loca-
devices connected to them and convert it into digital signals.
tions that require a single module.
The module’s on-board microprocessor analyzes the signal and
decides whether or not to input an alarm. • Automatic device mapping
Signature modules transmit information to the loop controller
The SIGA-CT1, SIGA-CT1HT and SIGA-CT2 mount to standard regarding their circuit locations with respect to other Signature
North American 1-gang electrical boxes, making them ideal for lo- devices on the wire loop.
cations where only one module is required. Separate I/O and data
• Electronic addressing
loop connections are made to each module.
Programmable addresses are downloaded from the loop con-
The SIGA-CT1HT module operates at an expanded temperature troller, a PC, or the SIGA-PRO Signature Program/Service Tool.
range of 32 ºF to 158 ºF (0 ºC to 70 ºC) for those applications There are no switches or dials to set.
requiring more extreme environmental temperature variation. • Ground fault detection by address
The SIGA-MCT2 is part of the UIO family of plug-in Signature Detects ground faults right down to the device level.
Series modules. It functions identically to the SIGA-CT2, but
takes advantage of the modular flexibility and easy installation that
characterizes all UIO modules. Two- and six-module UIO mother-
boards are available. All wiring connections are made to terminal
blocks on the motherboard. UIO assemblies may be mounted in
EDWARDS enclosures.

Page 1 of 4 D ATA S H E E T E85001-0241


Not to be used for installation purposes. Issue 1
Signature Series Overview UIO Motherboard

6-32
The Signature Series intelligent analog-addressable system from Self-tapping
EDWARDS Security is an entire family of multi-sensor detectors screws

and mounting bases, multiple-function input and output modules,


network and non-network control panels, and user-friendly mainte-
Plug-in (UIO) Captive
nance and service tools. Analog information from equipment con- Module screws
nected to Signature devices is gathered and converted into digital
signals. An onboard microprocessor in each Signature device
measures and analyzes the signal and decides whether or not to #6 Flat washers
input an alarm. The microprocessor in each Signature device pro-
vides four additional benefits – Self-diagnostics and History Log, Cabinet or electrical enclosure

Automatic Device Mapping, and Fast, Stable Communication.


Self-diagnostics and History Log – Each Signature Series Electronic Addressing - The loop controller electronically ad-
device constantly runs self-checks to provide important mainte- dresses each module, saving valuable time during system com-
nance information. The results of the self-check are automatically missioning. Setting complicated switches or dials is not required.
updated and permanently stored in its non-volatile memory. This Each module has its own unique serial number stored in its
information is accessible for review any time at the control panel, on-board memory. The loop controller identifies each device on
PC, or using the SIGA-PRO Signature Program/Service Tool. the loop and assigns a “soft” address to each serial number. If
Automatic Device Mapping –The Signature Data Control- desired, the modules can be addressed using the SIGA-PRO
ler (SDC) learns where each device’s serial number address is Signature Program/Service Tool.
installed relative to other devices on the circuit. The SDC keeps a EDWARDS recommends that this module be installed according
map of all Signature Series devices connected to it. The Signature to latest recognized edition of national and local fire alarm codes.
Series Data Entry Program also uses the mapping feature. With
interactive menus and graphic support, the wired circuits be-
tween each device can be examined. Layout or “as-built” drawing
information showing branch wiring (T-taps), device types and their Application
address are stored on disk for printing hard copy. The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de-
termined by their sub-type code or “Personality Code”. The code
is selected by the installer depending upon the desired application
Installation and is downloaded from the loop controller.
SIGA-CT1, SIGA-CT1HT and SIGA-CT2: modules mount to
North American 2½ inch(64 mm) deep 1-gang boxes and 1½ inch One personality code can be assigned to the SIGA-CT1. Two per-
(38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes
MP mounting plates. The terminals are suited for #12 to #18 AWG 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For
(2.5 mm2 to 0.75 mm2) wire size. example, personality code 1 can be assigned to the first address
(circuit A) and code 4 can be assigned to the second address
(circuit B).
Compatible electrical box
NORMALLY-OPEN ALARM - LATCHING (Personality Code 1)
- Assign to one or both circuits. Configures either circuit A or B or
both for Class B normally open dry contact initiating devices such
as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to
the loop controller when the input contact is closed. The alarm
Wall plate, white condition is latched at the module.
(1-gang)
NORMALLY-OPEN ALARM - DELAYED LATCHING (Person-
ality Code 2) - Assign to one or both circuits. Configures either
circuit A or B or both for Class B normally-open dry contact initiat-
ing devices such as Waterflow Alarm Switches. An ALARM signal
is sent to the loop controller when the input contact is closed for
ALAR
FIRE DULE
MO
M
approximately 16 seconds. The alarm condition is latched at the
Status LEDs module.

LED viewing ports


NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality
Code 3) - Assign to one or both circuits. Configures either circuit
A or B or both for Class B normally-open dry contact monitoring
input such as from Fans, Dampers, Doors, etc. An ACTIVE signal
is sent to the loop controller when the input contact is closed. The
SIGA-MCT2: mount the UIO motherboard inside a suitable ED- active condition is not latched at the module.
WARDS enclosure with screws and washers provided. Plug the NORMALLY-OPEN ACTIVE - LATCHING (Personality Code
SIGA-MCT2 into any available position on the motherboard and 4) - Assign to one or both circuits. Configures either circuit A or
secure the module to the motherboard with the captive screws. B or both for Class B normally open dry contact monitoring input
Wiring connections are made to the terminals on the motherboard such as from Supervisory and Tamper Switches. An ACTIVE signal
(see wiring diagram). UIO motherboard terminals are suited for #12 is sent to the loop controller when the input contact is closed. The
to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. active condition is latched at the module.

Page 2 of 4 D ATA S H E E T E85001-0241


Not to be used for installation purposes. Issue 1
Typical Wiring
Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes.
Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog
sheet for detailed wiring requirement specifications.
Initiating (Slave) Device Circuit Wire Specifications
Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit
Maximum Allowable Wire Capacitance 0.1µF per Circuit
For Design Reference: Wire Size Maximum Distance to EOLR
#18 AWG (0.75 mm²)
#16 AWG (1.00 mm²)
4,000 ft (1,219 m)
#14 AWG (1.50 mm²)
#12 AWG (1.50 mm²)

SIGA-CT1, SIGA-CT1HT SIGA-CT2

Typical NO Initiating Device

NOTES
UL/ULC Listed UL/ULC Listed
47KW EOL Input 2 Input 1
47KW EOL

1 Maximum 25 Ohm resistance per wire.



2 Maximum #12 AWG (2.5 mm² ) wire; Minimum #18 AWG (0.75 mm2). 1 2 4

3 Refer to Signature controller installation sheet for wiring specifications.

4 Maximum 10 Vdc @ 350 µA


MCT2
1 23 4
5 The SIGA-UIO6R and the SIGA-UIO2R do not come with TB14. 3
UIO(R) series motherboard

6 All wiring is supervised and power-limited. 4


Data In
3
7 These modules will not support 2-wire smoke detectors. 4
2
1
5

Signature 3 TB14 No connections required for


Data 2
MCT2
1
Circuit
TB7
473387351

Other modules may require


Data Out connections.

Warnings & Cautions


CAT NO.
MCT2

4
3
2
1
Green LED (Normal)
This module will not operate without electrical power. As fires fre- Red LED (Active)
TB15

quently cause power interruption, we suggest you discuss further


1 2 3 4

safeguards with your local fire protection specialist. No connections or jumper settings
required for MCT2.

SIGA-MCT2
Compatibility
These modules are part of EDWARDS’s Signature Series intelligent
processing and control platform. They are compatible with EST3,
EST3X and iO Series control panels.

Page 3 of 4 D ATA S H E E T E85001-0241


Not to be used for installation purposes. Issue 1
Specifications
Catalog Number SIGA-CT1HT SIGA-CT1 SIGA-CT2 SIGA-MCT2
Description Single Input Module Dual Input Module
Type Code 48 (factory set) Four sub-types 49 (factory set) Four sub-types
L I F E S A F E TY & I NCI DE NT M AN AGEM EN T
(personality codes) are available (personality codes) are available
Address Requirements Uses One Module Address Uses Two Module Addresses
Contact us... Standby = 396µA;
Operating Current Standby = 250µA;
Email: [email protected] Activated = 400µA Activated = 680µA
Web: Edwards-fire.com
Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal)
Construction High Impact Engineering Polymer
EDWARDS is a UTC brand.
Mounting North American 2½ inch (64 mm) deep one-gang box- UIO2R/6R/6
1016 Corporate Park Drive
Mebane, NC 27302 es and 1½ inch (38 mm) deep 4 inch square boxes Motherboard
with one-gang covers and SIGA-MP mounting plates
© 2016 United Technologies Corporation. Operating Environment 32°F to 158°F
32°F to 120°F (0°C to 49°C)
All rights reserved. (0°C to 70°C)
Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH
LED Operation On-board Green LED - Flashes when polled; On-board Red LED -
Flashes when in alarm/active.
Compatibility Use with Signature Loop Controller
Agency Listings UL, ULC, MEA, CSFM

Ordering Information
Catalog Ship Wt.
Description
Number lbs (kg)
SIGA-CT1 Single Input Module — UL/ULC Listed 0.4 (0.15)
SIGA-CT1HT Single Input Module High Temperature Operation UL/ULC Listed 0.4 (0.15)
SIGA-CT2 Dual Input Module — UL/ULC Listed 0.4 (0.15)
SIGA-MCT2 Dual Input Plug-in (UIO) Module — UL, ULC Listed 0.1 (0.05)

Related Equipment
27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6)
27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6)
Universal Input-Output Module Board w/Riser Inputs
SIGA-UIO2R 0.32 (0.15)
— Two Module Positions
Universal Input-Output Module Board w/Riser Inputs
Firmado electrónicamente por:
SIGA-UIO6R 0.62 (0.28)
JUAN PABLO — Six Module Positions
CORREA SIGA-UIO6 Universal Input-Output Module Board — Six Module Positions 0.56 (0.25)
Multifunction Fire Cabinet — Red, supports Signature Module
MFC-A 7.0 (3.1)
Mounting Plates
Transponder Mounting Bracket (allows for mounting
SIGA-MB4 0.4 (0.15)
two 1-gang modules in a 2-gang box)
SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70)
SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23)
SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46)

10-27-16

Page 4 of 4 D ATA S H E E T E85001-0241


Not to be used for installation purposes. Issue 1
BATERIA
12-35 12V35Ah

General purpose application series

Range Summary
Using oxygen recombination technology: maintenance-free
PbCaSn alloy for plate grids:low self discharge rate than
3% per month
High quality AGM separator: extend cycle life and
prevent micro short circuitretardant High purity raw
material: 99.99% pure lead

Application
Cable Television UPS
Communication Control Equipment
Equipment Medical Equipment
Security System Emergency Power ISO 9001 ISO14001 CE

Battery Dimensions Terminal


Dimensions

Technical Specifications
Battery Model JP12-35A

Designed 5 Years
Floating Life
20HR(1.85A,1.80V) 10HR(3.50A,1.80V) 5HR(5.98A,1.75V) 1HR(21.7A,1.60V)
Capacity(25C)o
37.0AH 35.0AH 29.9AH 21.7AH

Length Width Height Total Height


Dimensions
195mm(7.68inch) 130mm(5.12inch) 163mm(6.42inch) 168mm(6.61inch)

Approx. 10.4Kg (22.9 lbs)


Weight
Internal Full charged at 25C: 0.009 Ohmo
Resistance
Self Discharge 3% of capacity declined per month at (25Co )

Capacity 40oC 25oC 0Co -15oC


Affected by
Temp.(20HR) 109% 100% 85% 65%

Cycle use Float use


Charge
Voltage(25C)o 14.4-14.8V(-30mV/ oC), max. 13.6-13.8V(-18mV/ oC)
Current:10.5A
Page 1 of
BATERIA
12-35 12V35Ah
Discharge Characteristic (25C) o

(CA)

0.25
0.20

0.15
0.10
0.05

Relationship of OCV and state of charge Cycle service life

Constan current discharge rattings- amperes at 25 c

F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR
1.60V 202 139 109 69.3 45.5 18.3 12.8 7.42 3.87
1.67V 191 138 107 67.9 44.0 18.3 12.8 7.31 3.86
1.70V 179 134 106 66.2 42.8 18.3 12.8 7.25 3.86
1.75V 167 125 99.4 64.4 42.5 18.1 12.6 7.13 3.84
1.80V 149 117 93.5 62.7 41.7 17.8 12.4 7.01 3.71
1.85V 120 96.6 81.6 57.4 41.3 17.7 12.3 6.88 3.48
Constan power discharge ratings – watts at 25 C Firmado electrónicamente por:

JUAN PABLO
CORREA

F.V/Time
o 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR
1.60V 123 84.0 61.3 36.8 21.7 9.6 6.08 3.71 1.94
1.67V 110 76.7 59.5 35.7 21.7 9.5 6.03 3.66 1.93
1.70V 105 73.9 57.4 35.0 21.6 9.5 6.03 3.63 1.93
1.75V 93.1 68.3 54.3 34.3 21.4 9.45 5.98 3.57 1.92
1.80V 84.0 63.4 51.8 33.3 21.1 9.42 5.93 3.50 1.85
1.85V 63.7 52.2 44.8 30.6 20.9 9.38 5.88 3.44 1.74
BATERIA
12-55 12V55Ah

General purpose application series

Range Summary
Using oxygen recombination technology: maintenance-free
PbCaSn alloy for plate grids:low self discharge rate than 3% per
month
High quality AGM separator: extend cycle life and prevent micro
short circuitretardant High purity raw material: 99.99% pure lead

Application
Cable Television UPS Communication Control Equipment
Equipment Medical Equipment Security System Emergency
Power
ISO 9001 ISO14001 CE

Battery Dimensions Terminal Dimensions


) )

mm mm )
h
(8 (8 c
n
.1 .3 i
0
9i 1i 20 21 2
.
nc nc 8 1 0
(
h h m
m
5

Technical Specifications
JP12-55

16.5KG

Page 1 of 2
BATERIA
12-55 12V55Ah

General purpose application series


Discharge Characteristic (20C)o
Voltage
Capacity

Charge
Current
Charge
Charge

DischargeVoltage(V/Cell)
(CA)
0.25
0.20

0.15
0.10
0.05
0

Relationship of OCV and state of charge Cycle service life


BatteryVoltage(V/Cell)

CAPACITY(%)

Constant current discharge ratings-amperes at 20C o

F.V/Tim 5m in 10m 15m 30m 1h 3h 5h 10h 20h


e in in in
1.60V 193 132 96.3 57.8 36.3 15.0 9.55 5.83 3.05
1.67V 173 120 93.5 56.1 36.2 14.9 9.47 5.74 3.04
1.70V 164 116 90.2 55.0 36.0 14.8 9.42 5.70 3.03
1.75V 146 107 85.3 53.9 35.8 14.7 9.39 5.60 3.02
1.80V 132 100 81.4 52.3 35.3 14.6 9.32 5.50 2.91
1.85V 100 82.0 70.4 48.1 34.9 14.5 9.24 5.41 2.74
Constant power discharge ratings-watts at 20Co
F.V/Tim 5m in 10m 15m 30m 1h 3h 5h 10h 20h
e in in in
1.60V 317 219 171 109 71.5 28.8 18.4 11.7 6.09
1.67V 301 216 169 107 69.1 28.7 18.3 11.5 6.06
1.70V 281 211 166 104 67.3 28.6 18.2 11.4 6.04
1.75V 262 197 156 101 66.7 28.4 18.0 11.2 6.00
1.80V 235 183 147 98.5 65.6 28.0 17.8 11.0 5.82
1.85V 188 152 128 90.2 65.0 27.9 17.5 10.8 5.48

Page 2 of 2

Firmado electrónicamente por:

JUAN PABLO
CORREA
Survivable
EST3 Emergency Communications Platform

E S T B R A N D L I F E S A F E T Y & C O M M U N I C A T I O N S F R O M E D W A R D S
S
e
e
w
ha
t's ...
possible now
It is what it is.
...and then some.

Perfect for Any Facility


EST3 is uniquely designed to meet the life safety needs of any

size facility. The function of each panel is customized by using

an extensive selection of plug and play local rail modules. With

support for 64 nodes of up to 2,500 devices each, this network’s

multi-priority peer-to-peer token ring protocol delivers a fast alarm

response time across any size network. Add to that the ability to

network panels for an overall length in excess of 300,000 ft - that’s

nearly 60 miles - and you’ve got virtually unlimited networking

options. All EST3 operating features are software controlled using

object oriented rules, which when needed, gives the designer

great flexibility in integrating fire, security, and MNEC functions into

a single seamless design.

EST3 Audio. The Voice of Authority


EST3 multiplexed audio will deliver up to eight (8) audio messages

simultaneously over a single pair of wires! These messages can

be automatically directed to appropriate areas in a facility under

program control. Security messages can be easily integrated into

the audio system.


Fire, Security, Mass Notification

360
and much more...
No matter what your life safety needs are, EST’s EST3 platform ™
EST
is the total life safety solution for you. The EST3’s capabilities and

the interplay of its expanded functionality, enables this system to


-Sixty
provide a dynamic “synergy” that is unrivaled. EST3 is the perfect

life safety platform to integrate fire alarm, security and Mass Noti-

fication/Emergency Communications (MNEC) functions. Security


EST3 is the heart of
and MNEC functions take full advantage of the survivability and
EST3-Sixty™ — the powerful Edwards
reliability inherent to the EST3. The end result is a truly integrated
Mass Notification/Emergency
life safety solution that, by sharing system resources, results in
Communications solution.
reduced costs. Installing a single system is much more efficient

than installing multiple interconnected systems.


Distributed Intelligence events as soon as an alert is received. This Maintenance Made Easy.
= Survivability ensures that alarm messages are never Scheduled
The EST3’s distributed technology is de- inter-mixed with other lower priority system maintenance
signed to survive expected and unexpect- events. Paging and telephone operations are improves sys-
ed events. The EST3 network can be wired accomplished by using menu-driven switch- tem availability
so that a single open or short on the wiring es, not rows of confusing toggle switches. and the EST3’s
causes the system to isolate the fault, diagnostic
without any loss of network functionality.
Ideal for Retrofits
software
Intelligent Signature Series fire and security
Should multiple wiring faults occur, the net- makes quick work of troubleshooting. A
devices are listed for both fire and security
work automatically configures into many complete library of comprehensive PC-
applications, and are fully supported by the
sub-networks and continues to respond based system reports even includes a
EST3 system. Signature multisensor smoke
to alarm events from all communicating mapping diagram of Signature device
detectors are unmatched in performance
panels. Distributed technology insures that connections for easy-to-read “as built”
over a wide variety of fire conditions. All
panels isolated from the network remain drawings.
Signature Series devices take full advantage
fully functional.
of existing wiring, reducing retrofit installa-
Total Control tion costs for material and labor.
at Your Fingertips
User friendliness is a hallmark of the EST3

design. The main display

shows the operator the first

and most recent system


UL Listed Signaling UL Listed Fire Detection

UL Listed Security UL Listed Mass Notification

Only the
strong survive.
EST3: Held to a higher standard.
As the first such system listed by Underwriters Laboratories to their new UL 2572 Mass Notifica-

tion standard, EST3 charts new territory. But it does so with a unique combination of field-proven

crisis management tools and the latest communication technologies...

User Control/Display Modules mount Easily changed labels


Plug-in rail modules
over any rail module

Communication and
power bus rail

Hinged displays give


access to terminations

Ribbon cable
interconnect
of chassis

Two 3.5-amp
auxiliary
outputs per power Quick-snap
supply fasteners
secure modules

Removable terminal
blocks

Firefighter’s Telephone:
Large LCD simultaneously
displays incoming and
connected calls. Easy-to-
understand switches along
with text messages make
phone operation easy and
efficient.

One 24-volt battery backs up to four


Paging Microphone: power supplies
Use the paging microphone to give specific
area messages while simultaneously signaling
other areas with prerecorded voice and tone
signals.
Innovation, leadership,
and a rich tradition of excellence
Whether EST life safety systems are protecting the lives and livelihoods of the
people who make businesses run, or the lives entrusted to the care of public
institutions; whether they’re charged with protecting the guests of the world’s
finest hotels, or preserving irreplaceable artifacts that bring history to life; EST
stands alone as the brand closely associated with some of the most important
and far-reaching developments in the life safety industry today.

Firmado electrónicamente por:


Our strength is in our Strategic Partners — the people and organizations
JUAN PABLO
CORREA we entrust with the technology that has charted the course of life safety protec-
tion for decades. Strategic Partners are not middlemen or go-betweens. They
are independent contractors that form an integral part of the Edwards marketing
and support organization. As insiders, they enjoy exclusive access to products,
custom design innovations, specialized training, and pricing privileges. Yet
as successful independent contractors, they are adept at ensuring that each
submittal is strong and competitive, and that each bid is locally relevant to your
installation. As local businesses they not only have to earn your trust — they
have to keep it.

Together these strengths set EST installations apart, and have earned this

Detection & alarm since 1872


brand a special place among life safety and security solutions available today.

U.S.
Perhaps that’s why EST products and systems have become the choice of
T 888-378-2329
F 866-503-3996
building owners, architects and engineers around the globe. And why many of

Canada
the world’s most cherished landmarks are protected by Edwards products that
Chubb-Edwards
T 519 376 2430
bear the EST mark. From the Bibliotheca Alexandrina Museum in Egypt, to the
F 519 376 7258
modern-day sphinx at the Luxor Hotel in Las Vegas, professionals who design,
Southeast Asia
T : +65 6391 9300 own and occupy the world’s most impressive structures have come to know
F : +65 6391 9306
that the safest and most survivable solution today is an EST solution.
India
T : +91 80 4344 2000
F : +91 80 4344 2050
 
Australia See what’s possible now.
T +61 3 9239 1200
F +61 3 9239 1299 Contact your EST Strategic
Europe Partner today.
T +32 2 725 11 20
F +32 2 721 86 13

Latin America
T 305 593 4301
F 305 593 4300

utcfireandsecurity.com

© 2010 UTC Fire & Security.


All rights reserved.
06-21-10

85010-0124, Issue 5
Fuente de Alimentación
PS901 PS901B

Fuente de alimentación sin cables Fuente de alimentación con cables


Entrada: 220V AC, 50Hz (110V opcional) Entrada: 220V AC, 50Hz (110V opcional)
Salida: 12V DC Salida: 12V DC,
3A Máxima 3A Máxima
1.2A En operación 1.2A En operación
Batería no incluida de 12V 7Ah

PS902 PS902B

Fuente de alimentación con cables


Fuente de alimentación sin cables
Entrada: 220V AC, 50Hz (110V opcional)
Entrada: 220V AC, 50Hz (110V opcional)
Salida: 12V DC
Salida: 12V DC,
5A Máxima
5A Máxima
2A En operación
2A En operación
Batería no incluida de 12V 7Ah

12V, 3A Cargador de Batería

Código de fabricante: A17010105


Enchufe de dispositivo: 90°, φ2.1mm
Longitud del cable: 1,8 m
TPM005B TPM003B

Pieza de repuesto para inBio160 paquete B


Pieza de repuesto para inBio260/460 paquete B Fuente de alimentación para el controlador con la función
Fuente de alimentación para el controlador con la función de la batería
de la batería Entrada: 110-240 V AC, 50/60Hz
Entrada: 110-240 V AC, 50/60Hz Salida: 13,8 V/5A + 1A
Salida: 13,8 V/5A + 1A

ZKPSM030B

Pieza de repuesto para C3-100/200/400 paquete B


Fuente de alimentación para el controlador con la función
de la batería
Entrada: 110-240 V AC, 50/60Hz
Salida: 13,8 V/5A + 1A

Firmado electrónicamente por:

JUAN PABLO
CORREA

ZKTeco Latinoamérica
German Centre 3-2-02, Av. Santa Fe No. 170, Lomas de Santa Fe, Álvaro Obregón, 01210 México D.F.
(52) 55 - 5292 8418
www.zktecolatinoamerica.com

Derechos de Autor © 2015, ZKTeco, Inc. Todos los derechos reservados.


ZKTeco puede, en cualquier momento y sin previo aviso, realizar cambios o mejoras en los productos y servicios o detener su producción o comercialización.
El logo ZKTeco y la marca son propiedad de ZKTeco Inc.
EST Catalog u Intelligent Initiating

Manual Pull
Stations
SIGA-270, SIGA-270P,
SIGA-278 MEA

Patented
SIGA-270 SERIES

SIGA-278

Overview • Break glass operation


An up-front visible glass rod on the SIGA-270 discourages
The SIGA-270 and SIGA-278 series Manual Pull Stations are tampering.
part of EST’s Signature Series system. The SIGA-270 Fire Alarm
Manual Pull Stations feature our very familiar teardrop shape. They • Intelligent device with integral microprocessor
are made from die-cast zinc and finished with red epoxy powder- All decisions are made at the station allowing lower com-
coat paint complemented by aluminum colored stripes and mark- munication speed while substantially improving control panel
ings. With positive pull-lever operation, one pull on the station response time. Less sensitive to line noise and loop wiring
handle breaks the glass rod and turns in a positive alarm, ensuring properties; twisted or shielded wire is not required.
protection plus fool-proof operation. Presignal models (SIGA-270P) • ADA Compliant
are equipped with a general alarm (GA) keyswitch for applications Meets ADA requirements for manual pull stations.
where two stage operation is required. The up-front highly visible
glass rod discourages tampering, but is not required for proper • Electronic Addressing with Non-volatile memory
operation. Permanently stores programmable address, serial number,
type of device, and job number. Automatically updates historic
EST’s double action single stage SIGA-278 station is a contempo- information including hours of operation, last maintenance
rary style manual station made from durable red colored lexan. To date, number of alarms and troubles, and time and date of last
initiate an alarm, first lift the upper door marked “LIFT THEN PULL alarm.
HANDLE”, then pull the alarm handle.
• Automatic device mapping
Each station transmits wiring information to the loop control-
Standard Features ler regarding its location with respect to other devices on the
Note: Some features described here may not be supported by all control sys-
circuit.
tems. Check your control panel’s Installation and Operation Guide for details. • Stand-alone operation
The station inputs an alarm even if the loop controller’s polling
• Traditional familiar appearance
interrogation stops.
SIGA-270 models feature our familiar teardrop design with
simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs
Status LEDs; flashing GREEN shows normal polling; flashing
• One stage (GA), two stage (pre-signal), and double action
RED shows alarm state.
models
SIGA-270 models are available for one or two stage alarm • Designed for high ambient temperature operation
systems. The single stage double action SIGA-278 features a Install in ambient temperatures up to 120 °F (49 °C).
rugged Lexan housing with keyed reset mechanism.

Page 1 of 4 D ATA S H E E T 85001-0279


Not to be used for installation purposes. Issue 8
Application Typical Wiring
The operating characteristics of the fire alarm stations are deter- The fire alarm station’s terminal block accepts #18 AWG (0.75mm2)
mined by their sub-type code or “Personality Code”. NORMALLY- to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller
OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the catalog sheet for detailed wiring requirement specifications.
factory; no user configuration is required. The device is configured
for Class B IDC operation. An ALARM signal is sent to the loop Wiring Notes
controller when the station’s pull lever is operated. The alarm con-
1 Refer to Signature Loop Controller manual for maximum
dition is latched at the station.
wire distance.
2. All wiring is power limited and supervised.

Compatibility
Signature Series manual stations are compatible only with EST’s
Signature Loop Controller.

Warnings & Cautions


This device will not operate without electrical power. As fires fre-
quently cause power interruption, we suggest you discuss further
safeguards with your local fire protection specialist.

Testing & Maintenance


To test (or reset) the station simply open the station and operate
the exposed switch. The SIGA-270 series are opened with a tool;
the SIGA-278 requires the key which is supplied with that station.
The station’s automatic self-diagnosis identifies when it is defec-
tive and causes a trouble message. The user-friendly maintenance Figure 4. Single Stage Systems
program shows the current state of each Signature series device
and other pertinent messages. Single devices may be deactivated
temporarily, from the control panel. Availability of maintenance
features is dependent on the fire alarm system used.
Scheduled maintenance (Regular or Selected) for proper system
operation should be planned to meet the requirements of the
Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and
ULC CAN/ULC 536 standards.

Figure 5. Two Stage Systems

Page 2 of 4 D ATA S H E E T 85001-0279


Not to be used for installation purposes. Issue 8
Installation
Single-stage Signature Series fire alarm manual pull stations mount to North American 2½ inch (64 mm) deep 1-gang boxes.
Two stage presignal (270P) models require 1½ inch (38 mm) deep 4-inch square boxes with 1-gang, ½-inch raised covers. Openings
must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-13; in Canada, use Iberville Model CI-
52-C-49-1/2.
All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Edwards recommends that these fire alarm
stations be installed according to latest recognized edition of national and local fire alarm codes.
Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com-
missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board
memory. The loop controller identifies each device on the loop and assigns a “soft” address to each serial number. If desired, the stations
can be addressed using the SIGA-PRO Signature Program/Service Tool.

Figure 1. SIGA-278 installation Figure 2. SIGA-270, SIGC-270F, SIGC-270B installation

Cover Release
Screw

Comp atible
Electrical Box
with ½-inch
raised covers

Back
Plate

Toggle
Switch
MAL
NOR

LIFT Glass Rod


Release Lever
Do not use
boxes with
rounded
openings.

Figure 3. SIGA-270P, SIGC-270PB installation

Page 3 of 4 D ATA S H E E T 85001-0279


Not to be used for installation purposes. Issue 8
Specifications
SIGA-270, SIGC- SIGA-270P,
Catalog Number 270F, SIGC-270B SIGC-270PB SIGA-278
Single Action Single Action -Two Double Action
Description
- One Stage Stage (Presignal) - One Stage
Detection & alarm since 1872
Addressing Uses 1 Module Uses 2 Module Uses 1 Module
U.S. Requirements Address Addresses Address
T 888-378-2329 Standby = 250µA Standby = 396µA Standby = 250µA
F 866-503-3996 Operating Current
Activated = 400µA Activated = 680µA Activated = 400µA
Canada Diecast Zinc - Red Epoxy Lexan - Red with
Construction & Finish
Chubb Edwards with aluminum markings white markings
T 519 376 2430
Type Code Factory Set
F 519 376 7258
Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal)
Southeast Asia Operating Temperature: 32ºF to 120ºF (0ºC to 49ºC)
T : +65 6391 9300 Storage and Operating
Storage Temperature: -4ºF to 140ºF (-20ºC to 60ºC) Humidity: 0 to 93%
F : +65 6391 9306 Environment
RH
India On-board Green LED - Flashes when polled
T : +91 80 4344 2000 LED Operation On-board Red LED - Flashes w hen in alarm
F : +91 80 4344 2050 Both LEDs - Glow steady when in alarm (stand-alone)
  Compatibility Use With: Signature Loop Controller
Australia
T +61 3 9239 1200 Agency Listings UL, ULC (note 1), MEA, CSFM
F +61 3 9239 1299 Note: SIGC-270F, SIGC-270B and SIGC-270PB are ULC listed only. Suffix “F” indicates French markings.
Suffix “B” indicates English/French biling ual markings.
Europe
T +32 2 725 11 20
F +32 2 721 86 13

Latin America
Ordering Information
T 305 593 4301
F 305 593 4300 Ship
Catalog Wt. lbs
utcfireandsecurity.com Number Description (kg)
SIGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed
© 2010 UTC Fire & Security.
All rights reserved.
SIGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed
SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed
Two Stage (Presignal) Fire Alarm Station, English Markings - UL/ULC
SIGA-270P
Listed 1 (0.5)
SIGC- Two Stage (Presignal) Fire Alarm Station, French/English Markings
270PB - ULC Listed
Double Action (One Stage) Fire Alarm Station, English Markings
SIGA-278
- UL/ULC Listed

Accessories
32997 GA Key w/Tag - for pre-signal station (CANADA ONLY)
276-K2 GA Key - for pre-signal station (USA ONLY)
276-K1 Station Reset Key, Supplied with all Key Reset Stations
0.1 (.05)
27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY)
270-GLR 20 Glass Rods - for SIGA-270 series (USA ONLY)
276-GLR 20 Glass Rods - for SIGA-278 series
Firmado electrónicamente por: 276B-RSB Surface Mount Box, Red - for SIGA pull stations 1 (0.6)
JUAN PABLO
CORREA
05-18-11

Page 4 of 4 D ATA S H E E T 85001-0279


Not to be used for installation purposes. Issue 8
EDWARDS Catalog f Intelligent Initiating Devices

LIFE SAFETY & INCIDENT MANAGEMENT

Intelligent Smoke
Detector
SIGA-PD

S853

Overview Standard Features


The Signature Series SIGA-PD optical smoke detector brings ad- Note: Some features described here may not be supported by
vanced sensing technology to a practical design that increases ef- all control systems. Check your control panel’s Installation and
ficiency, saves installation time, cuts costs, and extends life safety Operation Guide for details.
and property protection capabilities. Continuous self-diagnostics
• Next Generation Optical Smoke Sensing Technology
ensure reliability over the long-haul, while environmental compen-
sation helps reduce maintenance costs. • Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
Like all Signature Series detectors, the SIGA-PD is an intelligent • Uses Existing Wiring
device that gathers analog information from its optical sensor, • Automatic Device Mapping
converting this data into digital signals. To make an alarm decision,
the detector’s on-board microprocessor measures and analyzes • Up To 250 Total Signature Addresses Per Loop
sensor readings and compares this information to historical data. • Two Levels of Environmental Compensation
Digital filters remove signal patterns that are not typical of fires,
thus virtually eliminating unwanted alarms. • Two Levels of Dirty Detector Warning
• Twenty Pre-Alarm Settings
• Five Sensitivity Settings
• Non-Volatile Memory
• Electronic Addressing
• Identification of Dirty or Defective Detectors
• Automatic Day/Night Sensitivity Adjustment
• Bicolor (Green/Red) Status Led
• Standard, Relay, Fault Isolator, and Audible Mounting Bases
• Sensor Markings Provide Easy Testing Identification

Page 1 of 4 D ATA S H E E T E85001-0646


Not to be used for installation purposes. Issue 1
Application Testing & Maintenance
The SIGA-PD detects extremely small particles of combustion and Each detector automatically identifies when it is dirty or defective
triggers an alarm at the first sign of smoke. Thanks to its high- and causes a “dirty detector” message. The detector’s sensitiv-
performance forward-scattering reflective response technology, ity measurement can also be transmitted to the loop controller. A
the photoelectric smoke sensor responds quickly and reliably to sensitivity report may be printed to satisfy NFPA sensitivity mea-
a wide range of fire types, especially slow burning fires fuelled by surements, which must be conducted at the end of the first year
combustibles typically found in modern multi-use buildings. and every two years thereafter.
The user-friendly maintenance program shows the current state
of each detector and other pertinent messages. Single detectors
Compatibility may be turned off temporarily from the control panel. Availability of
The SIGA-PD detector is compatible only with the Signature Loop maintenance features is dependent on the fire alarm system used.
Controller.

Accessories
Installation Detector mounting bases have wiring terminals that are acces-
sible from the “room-side” after mounting the base to the electrical
Signature Series detectors mount
box. The bases mount to North American 1-gang boxes and to
to North American 1-gang boxes, 3½ inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They
3-1/2 inch or 4 inch octagon also mount to European BESA and 1-gang boxes with 60.3 mm
Self-locking tab
boxes, and to 4 inch square elec- fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-IB4 mount to
trical boxes 1-1/2 inches (38 mm) North American 4 inch sq. electrical boxes in addition to the above
deep. They mount to European boxes. They include the SIGA-TS4 Trim Skirt, which is used to
BESA and 1-gang boxes with 60.3 cover the “mounting ears” on the base. The SIGA-AB4G mounts
mm fixing centers. See mounting LED Indicator to a 4 inch square box only.
base installation and wiring for
more information.

Sensing and reporting technology SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED


Audible Base Standard Base Isolator Base Relay Base Remote LED
The microprocessor in each detector provides additional benefits -
Self-diagnostics and History Log, Automatic Device Mapping, and Remote LED SIGA-LED - The remote LED connects to the
Fast, Stable Communication. SIGA-SB or SIGA-SB4 Standard Base only. It features a North
American size 1-gang plastic faceplate with a white finish and red
Self-diagnostics and History Log - Each Signature Series alarm LED.
detector constantly runs self-checks to provide important mainte-
nance information. The results of the self-check are automatically SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also
be ordered separately to use with the other bases to help hide
updated and permanently stored in the detector’s non-volatile
surface imperfections not covered by the smaller bases.
memory
Sounder Bases - Signature Series sounder bases are designed
Automatic Device Mapping - The loop controller learns where for use where localized or group alarm signaling is required.
each device’s serial number address is installed relative to other
• SIGA-AB4G bases provide sounder capability to Signature
devices on the circuit. The mapping feature provides supervision
Series to heat and smoke detectors. They are not intended
of each device’s installed location to prevent a detector from being for use with combination carbon monoxide detectors in Fire-
reinstalled (after cleaning etc.) in a different location from where it plus-CO mode.
was originally.
• SIGA-AB4GT bases provide sounder capability to Signature
Fast Stable Communication - On-board intelligence means less Series smoke and heat detectors, as well as carbon monox-
information needs to be sent between the detector and the loop ide detectors when used with a SIGA-TCDR Temporal Pattern
controller. Other than regular supervisory polling response, the Generator.
detector only needs to communicate with the loop controller when • SIGA-AB4G-LF bases provide 520 Hz low frequency
it has something new to report. sounder capability to Signature Series smoke and heat detec-
tors, as well as carbon monoxide detectors when used with a
SIGA-TCDR Temporal Pattern Generator. The SIGA-AB4G-LF
is suitable for applications requiring low frequency audible
tones.

Page 2 of 4 D ATA S H E E T E85001-0646


Not to be used for installation purposes. Issue 1
Typical Wiring
The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode
(1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm²) wire sizes. AB4GT, AB4G, AB4G-LF sounder bases
Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred
for ease of installation.

SIGA-AB4GT, SIGA-AB4G-LF:
Standard Detector Base, SIGA-SB, SIGA-SB4 SIGA-AB4G, Output Mode
SIGA-AB4G-LF: Jumper cuts Default = Fire
This is the basic mounting base Remote LED Volume Setting Cut/remove jumper for
for EDWARDS Signature Series Default = High Fire plus CO
Max resistance
per wire Cut/remove
detectors. The SIGA-LED Re- must not exceed jumper for SIGA-AB4G:
mote LED is supported by this 10 Ohms low dB Tone Setting
Default = Temporal
Base. SIG+ SIG-
DATA- DATA- DATA+
OUT IN IN/OUT Cut/remove jumper for
Term Description
Steady
1 Not Used
2 DATA IN/OUT (+)
3 Not Used SIGA-AB4GT:
4 DATA IN (-) Not Used
4 Remote LED (-) DATA IN (-) DATA OUT (-)
5 Remote LED (+)
6 Not Used
7 DATA OUT (-) DATA IN (+) DATA OUT (+) 24 Vdc in
- - 24 Vdc out
From Signature Controller To Next Device From power supply
or Previous Device or previous base + + To next base or EOL relay

-
Data out
Data in -
From Signature Controller to next Signature device
Isolator Detector Base, SIGA-IB, SIGA-IB4 or previous device + +

This base includes a built-in line fault isolator for use on Class A
circuits. A detector must be installed for it to operate. The isolator
base does not support the SIGA-LED Remote LED.
Warnings & Cautions
The isolator operates as follows:
• This detector does not operate without electrical power. As
- a short on the line causes all iso- fires frequently cause power interruption, discuss further
lators to open within 23 msec safeguards with the local fire protection specialist.
- at 10 msec intervals,
beginning on one side • This detector does not sense fires in areas where smoke
of the Class A cannot reach the detector. Smoke from fires in walls, roofs,
circuit nearest the loop or on the opposite side of closed doors may not reach the
controller, the isolators detector.
close to provide the
next isolator down the • Photoelectric detectors have a wide range of fire-sensing
line with power Term Description capabilities and are best suited for detecting slow, smolder-
1 Not Used
- when the isolator next 2 DATA IN/OUT (+) ing fires.
3 DATA IN (-)
to the short closes, it reopens within 10 4 Not Used • In Canada, install according to CAN/ULC-S524 Standard for
msec. 5 Not Used
6 DATA OUT (-) the Installation of Fire Alarm Systems, CSA C22.1 Canadian
The process repeats beginning on the 7 Not Used
Electrical Code, and the local authority having jurisdiction.
other side of the loop controller.

Relay Detector Base, SIGA-RB, SIGA-RB4


This base includes a relay. Nor-
mally Open or Normally Closed
operation is selected during in-
stallation. The dry contact is rated
for 1 amp (pilot duty) @ 30 Vdc.
The relay’s position is supervised
to avoid accidentally jarring it out
of position. The SIGA-RB can be
operated as a control relay if pro-
grammed to do so at the control
panel. The relay base does not
Term Description
support the SIGA-LED Remote 1 Normally Open
LED. CONTACT RATING 2 DATA IN/OUT (+)
1.0 Amp @ 30 VDC 3 Common
(Pilot Duty) 4 DATA IN (-)
5 Not Used
6 Normally-Closed
7 DATA OUT (-)

Page 3 of 4 D ATA S H E E T E85001-0646


Not to be used for installation purposes. Issue 1
Dimensions

L I F E S A F E TY & I NCI DE NT M AN AGEM EN T

Contact us...
Email: edwards.fi[email protected]
Web: Edwards-fire.com

EDWARDS is a UTC brand.


1016 Corporate Park Drive
Mebane, NC 27302

© 2016 United Technologies Corporation.


All rights reserved.
Specifications
Operating voltage 15.20 to 19.95 VDC
Normal operating current 32 μA
Alarm current 32 μA
Smoke Sensitivity Range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Vibration level 10 to 35 Hz, with an amplitude of 0.01 in.
Air velocity 0 to 4,000 ft./min (0 to 20 m/s)
Wall mounting 12 in. (305 mm) max. from ceiling
Compatible bases See Ordering Information
Compatible detector testers Testifire 1000, Testifire 2000
Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing
Construction High Impact Engineering Polymer, White
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic
Agency Listings CAN/ULC-S529, UL 268, UL 268A

Ordering Information
Catalog Ship Wt.
Description
Number lbs (kg)
Firmado electrónicamente por:
SIGA-PD Intelligent Optical Smoke Detector 0.4 (0.16)
JUAN PABLO
CORREA Accessories
SIGA-SB Detector Mounting Base - Standard
SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt
SIGA-RB Detector Mounting Base w/Relay
SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09)
SIGA-IB Detector Mounting Base w/Fault Isolator
SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt
SIGA-LED Remote Alarm LED (not for EN54 applications)
SIGA-AB4G Audible (Sounder) Base for Fire Detectors 0.3 (0.15)
SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04)
SIGA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04)
SIGA-DMP Detector Mounting Plate 3.0 (1.4)
SIGA-RTA Detector Removal Tool
SIGA-VA Detector Cleaning Tool
10-11-16

Page 4 of 4 D ATA S H E E T E85001-0646


Not to be used for installation purposes. Issue 1
EDWARDS® Catalog  Intelligent Initiating Devices

LIFE SAFETY & INCIDENT MANAGEMENT

Intelligent
Multisensor Smoke
and Heat Detector
SIGA-PHD, SIGA-PHDB

S853

Overview Standard Features


The Signature Series SIGA-PHD detector brings advanced Note: Some features described here may not be supported by
multisensor technology to a practical design that increases all control systems. Check your control panel’s Installation and
efficiency, saves installation time, cuts costs, and extends Operation Guide for details.
life safety and property protection capabilities. Continuous
• Next Generation Detection Technology
self-diagnostics ensures reliability over the long-haul, while
environmental compensation helps reduce maintenance costs. • Integrates optical smoke with rate-of-rise heat sensing
The SIGA-PHD provides an optical smoke sensor and a rate- • Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
of-rise heat sensor with a fixed temperature setting. Together • Uses existing wiring
these sensors efficiently detect smoldering fires, as well as fast
flaming fires. • Automatic device mapping

Like all Signature Series detectors, the SIGA-PHD gathers analog • Sensor Markings Provide Easy Testing Identification
information from its sensing elements and converts this data into • Up To 250 Total Signature Addresses Per Loop
digital signals. To make an alarm decision, the detector’s on-board
microprocessor measures and analyzes smoke and heat sensor • Two levels of environmental compensation
readings and compares this information to historical data. Digital • Two levels of dirty detector warning
filters remove signal patterns that are not typical of fires, thus
virtually eliminating unwanted alarms. • Twenty pre-alarm settings
• Five sensitivity settings
• Non-volatile memory
• Electronic addressing
• Environmental compensation
• Automatic day/night sensitivity adjustment
• Bicolor (green/red) status LED
• Standard, relay, fault isolator, and audible mounting bases

Page 1 of 4 D ATA S H E E T E85001-0650


Not to be used for installation purposes. Issue 1.2
Application Automatic Device Mapping - The loop controller learns where
each device’s serial number address is installed relative to other
Smoke detection devices on the circuit. The mapping feature provides supervision
The SIGA-PHD detects extremely small particles of combustion of each device’s installed location to prevent a detector from being
and triggers an alarm at the first sign of smoke. Thanks to its high- reinstalled (after cleaning etc.) in a different location from where it
performance forward-scattering reflective response technology, was originally.
the photoelectric smoke sensor responds quickly and reliably to
a wide range of fire types, espe­cially slow burning fires fuelled by Fast Stable Communication - On-board intelligence means less
combustibles typically found in modern multi-use buildings. information needs to be sent between the detector and the loop
controller. Other than regular supervisory polling response, the
Heat detection detector only needs to communicate with the loop controller when
SIGA-PHD’s on-board rate-of-rise heat sensor provides a 15 °F it has something new to report.
(9 °C) per minute for the detection of fast-developing fires while
also providing a 135 °F (57.2 °C) fixed detection threshold. The Accessories
heat sensors monitor the temperature of the air and determines
Detector mounting bases have wiring terminals that are
whether an alarm should be initiated.
accessible from the “room-side” after mounting the base to the
electrical box. The bases mount to North American 1-gang boxes
Compatibility and to 3½ inch or 4 inch octagon boxes, 1½ inches (38 mm)
deep. They also mount to European BESA and 1-gang boxes with
The SIGA-PHD detector is compatible only with the Signature
60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-IB4
Loop Controller.
mount to North American 4 inch sq. electrical boxes in addition to
the above boxes. They include the SIGA-TS4 Trim Skirt, which is
Installation used to cover the “mounting ears” on the base. Sounder bases
mount to a 4 inch square boxes only.
Signature Series detectors mount
to North American 1-gang boxes,
3-1/2 inch or 4 inch octagon
boxes, and to 4 inch square Self-locking tab

electrical boxes 1-1/2 inches


(38 mm) deep. They mount to SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED
European BESA and 1-gang Audible Base Standard Base Isolator Base Relay Base Remote LED
boxes with 60.3 mm fixing LED Indicator
Remote LED SIGA-LED - The remote LED connects to the
centers. See mounting base
SIGA-SB or SIGA-SB4 Standard Base only. It features a North
installation and wiring for
American size 1-gang plastic faceplate with a white finish and
more information.
red alarm LED.
SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also
Testing & Maintenance be ordered separately to use with the other bases to help hide
Scheduled maintenance (regular or selected) for proper surface imperfections not covered by the smaller bases.
detector operation should be planned to meet the requirements
of the Authority Having Jurisdiction (AHJ). Refer to current Sounder Bases - Signature Series sounder bases are designed
NFPA 72, NFPA 720, and ULC CAN/ULC 536 standards. for use where localized or group alarm signaling is required.
• SIGA-AB4G bases provide sounder capability to Signature
Smoke Sensor Sensitivity
Series smoke and heat detectors. They are not for use with
The SIGA-PHD determines when its optical sensor is dirty or
devices that include a CO sensor.
defective and can transmit sensitivity data to the loop controller.
A sensitivity report can also be printed to satisfy NFPA sensitivity • SIGA-AB4GT bases provide sounder capability to Signature
measurements which must be conducted at the end of the first Series smoke and heat detectors, as well as Signature
year and every two years thereafter. The availability of maintenance detectors that include a CO Sensor when used with a SIGA-
features depends on the fire alarm system used. TCDR Temporal Pattern Generator to separate CO (TC4) and
Fire (TC3) tone patterns.
• SIGA-AB4G-LF bases provide 520 Hz low frequency
Sensing and reporting technology sounder capability to Signature Series smoke and heat
The microprocessor in each detector provides additional detectors, as well as Signature detectors that include a CO
benefits – Self-diagnostics and History Log, Automatic Device Sensor when used with a SIGA-TCDR Temporal Pattern
Mapping,and Fast, Stable Communication. Generator to separate CO (TC4) and Fire (TC3) tone patterns.
Self-diagnostics and History Log - Each Signature Series The SIGA-AB4G-LF is suitable for applications requiring low
detector constantly runs self-checks to provide important frequency audible tones.
maintenance information. The results of the self-check are
automatically updated and permanently stored in the detector’s
non-volatile memory.

Page 2 of 4 D ATA S H E E T E85001-0650


Not to be used for installation purposes. Issue 1.2
Typical Wiring
The detector mounting bases accept #18 AWG (0.75mm2), Audible Sounder Bases, Fire Mode
#16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm²) AB4GT, AB4G, AB4G-LF sounder bases
wire sizes. Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2)
are preferred for ease of installation.
SIGA-AB4GT, SIGA-AB4G-LF:
Standard Detector Base, SIGA-SB, SIGA-SB4 SIGA-AB4G,
Jumper cuts
Output Mode
SIGA-AB4G-LF: Default = Fire
This is the basic mounting base Remote LED
Volume Setting
Default = High
Cut/remove jumper
for Fire plus CO
for EDWARDS Signature Series Max resistance Cut/remove
detectors. The SIGA-LED per wire
must not exceed
jumper for SIGA-AB4G:
low dB Tone Setting
Remote LED is supported 10 Ohms Default = Temporal
by this Base. DATA- DATA- DATA+
SIG+ SIG- OUT IN IN/OUT Cut/remove jumper
Term Description for Steady
1 Not Used
2 DATA IN/OUT (+) SIGA-AB4GT:
3 Not Used Not Used
4 DATA IN (-)
4 Remote LED (-) DATA IN (-) DATA OUT (-)
5 Remote LED (+)
6 Not Used 24 Vdc in
7 DATA OUT (-) DATA IN (+) DATA OUT (+) - - 24 Vdc out
From power supply
From Signature Controller To Next Device + To next base or EOL relay
or previous base +
or Previous Device
-
Data out
Data in -
From Signature Controller to next Signature device
Isolator Detector Base, SIGA-IB, SIGA-IB4 or previous device + +

This base includes a built-in line fault isolator for use on Class A
circuits. A detector must be installed for it to operate. The isolator
base does not support the SIGA-LED Remote LED.
The isolator operates as follows: Warnings & Cautions
- a short on the line causes all • This detector does not operate without electrical power.
isolators to open within 23 msec As fires frequently cause power interruption, discuss further
safeguards with the local fire protection specialist.
- at 10 msec intervals,beginning
on one side of the Class A • This detector does not sense fires in areas where smoke or
circuit nearest the loop heat cannot reach the detector. Smoke or heat from fires in
controller, the isolators walls, roofs, or on the opposite side of closed doors may not
close to provide the reach the detector.
next isolator down
the line with power • Photoelectric detectors have a wide range of sensing
capabilities, and are best suited for detecting slow, smoldering
- when the isolator next
Term Description fires. The heat sensor in this device provides a source of
to the short closes, it 1 Not Used
supplemental information. The heat sensor by itself does
reopens within 10 msec. 2 DATA IN/OUT (+)
3 DATA IN (-) not provide life safety protection.
The process repeats beginning on

4 Not Used
5 Not Used
the other side of the loop controller. 6 DATA OUT (-)
• In Canada, install according to the CAN/ULC-S524
7 Not Used Standard for the Installation of Fire Alarm Systems, the
CSA C22.1 Canadian Electrical Code, and the local authority
Relay Detector Base, SIGA-RB, SIGA-RB4 having jurisdiction.

This base includes a relay. • Upon completion of the original installation and following any
Normally Open or Normally modifications or additions to the system, perform a calibrated
Closed operation is selected sensitivity test per NFPA code. Signature Series devices
during installation. The dry can perform this test and the panel can generate a system
contact is rated for 1 amp sensitivity report.
(pilot duty) @ 30 Vdc. The
relay’s position is supervised
to avoid accidentally jarring it
out of position. The SIGA-RB
can be operated as a control
relay if programmed to do so
Term Description
at the control panel. The relay 1 Normally Open
base does not support the CONTACT RATING 2 DATA IN/OUT (+)
1.0 Amp @ 30 VDC 3 Common
SIGA-LED Remote LED. (Pilot Duty) 4 DATA IN (-)
5 Not Used
6 Normally-Closed
7 DATA OUT (-)

Page 3 of 4 D ATA S H E E T E85001-0650


Not to be used for installation purposes. Issue 1.2
Dimensions

L I F E S A F E TY & I NCI DE NT M AN AGEM EN T

Contact us...
Email: [email protected]
Web: edwards-fire.com

1016 Corporate Park Drive


Mebane, NC 27302

EDWARDS is a registered mark in the


United States and other countries.

© 2018 United Technologies Corporation.


All rights reserved.

Specifications
Operating voltage 15.20 to 19.95 VDC
Normal operating current 51 µA
Alarm current 68 µA
Vibration level 10 to 35 Hz, with an amplitude of 0.01 in.
Smoke Sensitivity Range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Rate-of-rise rating 15°F/min (8°C/min)
Fixed temperature rating 135°F (57.2°C). Actual alarm point 129 to 141°F (53.9 to 60.6°C).
Air velocity 0 to 4,000 ft./min (0 to 20.32 m/s)
Wall mounting 12 in. (305 mm) max. from ceiling
Spacing, heat detectors Max. 50 ft. (15.2 m) centers
Compatible bases See Ordering Information
Compatible detector testers Testifire 1000, Testifire 2000
Operating environment 32 to 100°F (0 to 38°C), 0 to 93% RH, noncondensing
Construction High Impact Engineering Polymer, White
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic
Agency Listings CAN/ULC-S529, CAN/ULC-S530, UL 268, UL 268A, UL 521
CSFM, FM approved.

Firmado electrónicamente por:

JUAN PABLO
CORREA
Ordering Information
Catalog Ship Wt.
Description
Number lbs (kg)
SIGA-PHD Intelligent Multisensor Smoke and Heat Detector 0.4 (0.16)
Intelligent Multisensor, Smoke and Heat Detector, Black.
SIGA-PHDB 0.4 (0.16)
Use with SIGA-TSB.

Compatible Bases
SIGA-SB Detector Mounting Base - Standard
SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt
SIGA-RB Detector Mounting Base w/Relay
SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09)
SIGA-IB Detector Mounting Base w/Fault Isolator
SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt
SIGA-LED Remote Alarm LED (not for EN54 applications)
SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (.04)
SIGA-TSB Trim Skirt for 4” Base, Black 0.1 (.04)
SIGA-DMP Detector Mounting Plate 3.0 (1.4)
SIGA-RTA Detector Removal Tool
SIGA-VA Detector Cleaning Tool
05-17-18

Page 4 of 4 D ATA S H E E T E85001-0650


Not to be used for installation purposes. Issue 1.2
原门市公兴隆冷气设备有限公司
ZHONGXINGLONG
XIAMEN ZHONGXINGLONG AIR CONDITIONIN EQUIPMENT CO., LTD.

DANPER AMORTIGUAGOR O SWITCH ANTIFUEGO CON


RECUBRIMIENTO CERÁMICO

Probado y conformado a UL555 (prueba de resistencia al fuego 4 horas)

APLICACIÓN
El amortiguador de incendios paralelo ZXL ha sido
desarrollado para proporcionar la versatilidad requerida
para la compleja y sofisticada protección contra
incendios y construcción de seguridad de hoy en día
sistema. También es una cuchilla ajustable para este
amortiguador de fuego motorizado (FD-M)

MATERIAL
Marco: acero galvanizado de 1.8mm
Hoja: acero galvanizado de 1.5 mm

ACABADO DE LA SUPERFICIE
Revestimiento cerámico

HOJA DE ACCIÓN
Cuchilla paralela

EJES
Barra cuadrada (12.7mm) de acero chapado

SOPORTE
Casquillo de bronce presionado en el marco

LÍMITE DE LA DIMENSIÓN DE LA HOJA


Max. Longitud de la cuchilla = 1000 mm
Max. Ancho de la hoja = 160 mm

FLANGED
Junta deslizante o articulación TDC

MONTAJE Y ESQUEMA
Durante el fuego, se enviará una señal desde el sensor o la unidad de control al actuador
de FD-M.
Al recibir la señal, FD-M se cerrará por medio del actuador.
FD-M1 Actuador montado expuesto al costado del amortiguador de incendios
FD-M2 Actuador montado en un compartimento en la esquina del amortiguador de
incendios
FD-M3 Actuador montado en un compartimiento en el lateral del amortiguador de
incendios

Dibujos

FD-M1 FD-M2 FD-M3

DATOS DE RENDIMIENTO (recubrimiento cerámico)

Para determinar la caída de presión


1. Seleccione el área del amortiguador (ft2) según el ancho (W) y la altura (H) de la
tabla que se muestra a continuación.
2. Dada la velocidad del aire y el tamaño del amortiguador, sustituya el área libre (ft2)
en la fórmula siguiente y
obtener el valor de caída de presión. Por favor, tome nota de la unidad de parámetros.

Todos los datos han sido diseñados para representar el aire estándar a una densidad de
0.075 lb / ft3; y generado en las cuchillas del amortiguador están completamente
abiertas.

ΔP = 2.75 * {(Q / Área libre - V) / 4005} 2


ΔP = Caída de presión (pulgadas W.G.) V = Velocidad del aire del conducto (fpm)
Q = Velocidad del flujo de aire (cfm) = Área del conducto (ft2) * Velocidad del aire del
conducto (fpm)
Ejemplo: ΔP = 2.75 * {(2690 / 1.91 - 1000) / 4005} 2
= 1000fpm = 0.0286 pulgadas W.G.
=7,12 Pa

Dado: velocidad del aire del conducto = 1000fpm


Tamaño del conducto = tamaño del regulador = 500 mm (W) * 500 mm (H)
Área del conducto = 2.69 ft2

Superficie por recubrimiento cerámico


Encuentra caída de presión?
Q = Área del conducto (ft2) * Velocidad del aire del conducto (fpm) = 2.69 * 1000 =
2690 CFM
Consulte la tabla de arriba, área libre para el tamaño de compuerta 500W * 500H = 1.91

Firmado electrónicamente por:

JUAN PABLO
CORREA
Cerraduras Electromagnéticas
Serie LM

LM-180 LM-280 LM-350 LM-500

Las cerraduras electromagnéticas aplican el principio del electromagnetismo. Cuando la corriente eléctrica pasa a
través de la hoja de acero al silicio, la cerradura electromagnética producirá una fuerte fuerza de succión para atraer
firmemente la placa de hierro para bloquear la puerta.

Una pequeña corriente eléctrica producirá una gran fuerza magnética. Cuando los usuarios apagan la alimentación de
la cerradura electromagnética, perderá su succión, por lo que los usuarios pueden abrir la puerta.

Especificaciones
Serie de Modelos LM180

Foto

Modelo LM1802 LM1805


Fuente de Alimentación DC12V DC12V
Corriente de Trabajo 420mA ± 5% 420mA ± 5%
+15°C
Aumento de la Temperatura (Temperatura ambiente de 29 ° C; 6 horas después de que se energiza DC 12V.
La temperatura del cuerpo de la cerradura es de 41 ° C)

Rojo: +
Negro: -
Rojo: +
Interfaz Amarillo: NO
Negro: - Verde: COM
Blanco: NC
Rango de Fuerza de Tracción 120kg ± 8% 120kg ± 8%
Cuerpo cerradura: 170*40*20(mm) Cuerpo cerradura: 170*40*20(mm)
Dimensiones (W*H*D) Placa de hierro: 130*33*11(mm) Placa de hierro: 130*33*11(mm)
Peso Bruto 1.016kg 1.029kg
Dimensiones (mm)

LMB-180L / 180U / 180Z / 180ZL


Soportes de Montaje
LMD-180L / 180Z / 180ZL

Serie de Modelos LM280

Foto

Modelo LM2802 LM2805


Fuente de Alimentación DC12V DC12V
Corriente de Trabajo 450mA ± 5% 450mA ± 5%
+15°C
Aumento de la Temperatura (Temperatura ambiente de 29 ° C; 6 horas después de que se energiza DC 12V.
La temperatura del cuerpo de la cerradura es de 41 ° C)

Rojo: +
Negro: -
Interfaz Rojo: + Amarillo: NO
Negro: - Verde: COM
Blanco: NC
Rango de Fuerza de Tracción 200kg ± 5% 200kg ± 5%

Dimensiones (W*H*D) Cuerpo cerradura: 250*47*25.5 (mm) Cuerpo cerradura: 250*47*25.5 (mm)
Placa de hierro: 180*38*11 (mm) Placa de hierro: 180*38*11 (mm)
Peso Bruto 1.77kg 1.77kg

Dimensiones (mm)

LMB-280L / 280U / 280Z / 280ZL


Soportes de Montaje LMD-280L / 280Z / 280ZL

Serie de Modelos LM350

Foto

Modelo LM3502 LM3505


Fuente de Alimentación DC12V DC12V
Corriente de Trabajo 400mA ± 5% 420mA ± 5%
+15°C
Aumento de la Temperatura (Temperatura ambiente de 29 ° C; 6 horas después de que se energiza DC 12V.
La temperatura del cuerpo de la cerradura es de 41 ° C)
Rojo: +
Negro: -
Rojo: + Amarillo: NO
Interfaz Negro: - Verde: COM
Blanco: NC
Rango de Fuerza de Tracción 240kg ± 5% 240kg ± 5%
Cuerpo cerradura: 246*56.5*27.5(mm) Cuerpo cerradura: 246*56.5*27.5(mm)
Dimensiones (W*H*D) Placa de hierro: 158*43*11(mm) Placa de hierro: 158*43*11(mm)

Peso Bruto 2.07kg 2.07kg

Dimensiones (mm)

Soportes de Montaje LMB-350L / 350U / 350Z / 350ZL

Serie de Modelos LM500

Foto

Modelo LM5002 LM5005


Fuente de Alimentación DC12V DC12V
Corriente de Trabajo 410mA ± 5% 450mA ± 5%
+15°C
Aumento de la Temperatura (Temperatura ambiente de 29 ° C; 6 horas después de que se energiza DC 12V.
La temperatura del cuerpo de la cerradura es de 41 ° C)

Rojo: +
Interfaz Rojo: + Amarillo: NO
Negro: - Verde: COM
Blanco: NC
Rango de Fuerza de Tracción 410kg ± 5% 410kg ± 5%

Dimensiones (W*H*D) Cuerpo cerradura: 265*74.7*39(mm) Cuerpo cerradura: 265*74.7*39(mm)


Placa de hierro: 185*60*16(mm) Placa de hierro: 185*60*16(mm)
Peso Bruto 4.33kg 4.33kg

Dimensiones (mm)

Soportes de Montaje LMB-500L / 500Z / 500ZL


Instalación de Soportes de Montaje (L / U / Z / ZL)

Firmado electrónicamente por:

JUAN PABLO
CORREA

Derechos de Autor © 2021, ZKTeco CO., LTD. Todos los derechos reservados.
ZKTeco puede, en cualquier momento y sin previo aviso, realizar cambios o
mejoras en los productos y servicios o detener su producción o comercialización.
El logo ZKTeco y la marca son propiedad de ZKTeco CO., LTD.
www.zkteco.com www.zktecolatinoamerica.com
Serie InBio Pro
Paneles IP Biométricos para Control de Acceso
InBio-160 Pro InBio-460 Pro

InBio-260 Pro InBio-460 Pro Paquete B

La serie InBio Pro es una línea de productos de alta gama orientada a proyectos con características
únicas, tales como verificación de huellas digitales y funciones avanzadas de control de acceso, que
pueden ser gestionadas por comunicación TCP/IP a través de redes LAN o WAN.

La serie InBio Pro es el complemento perfecto del software basado en web ZKBioSecurity para
proporcionar una solución de seguridad biométrica completa.

Por medio de la comunicación RS485 de un lector FR1500, los paneles pueden verificar usuarios
mediante múltiples métodos de verificación, tales como reconocimiento de huella digital, de
tarjeta y contraseña para un mayor nivel de seguridad.
Caracteristicas
Identificación Biométrica Interna Controladores de Puerta y Otras Funciones
La serie de lectores FR transmiten las plantillas de las Después de la programación, los relevadores
huellas al panel vía RS485 para identificar rápidamente las auxiliares pueden funcionar como luces, alarmas
plantillas almacenadas en la base de datos. Las entradas y paneles de detección de intrusiones; y pueden
Wiegand permiten utilizar lectores RFID tradicionales. gestionarse mediante el mismo software de
administración.
Comunicación
Opciones
Los paneles se instalan de forma sencilla en la red y
soportan comunicación HTTP/HTTPS. El Webserver 3 diferentes tamaños para poder adaptarse a las
permite configurar y modificar los parametros de la red necesidades de cada proyecto y disminuir los costos que
de forma sencilla. puede generar la capacidad no utilizada. Modelos para
1, 2 y 4 puertas pueden ser combinados para lograr un
sistema optimizado.
Capacidad
El sistema soporta hasta 20.000 plantillas de huellas Avanzado Control de Acceso Integrado
digitales, 60.000 tarjetas y almacena hasta 100.000 eventos
y transacciones. La información permanece guardada Cuentan con funciones avanzadas de control de acceso
en la memoria interna en caso de pérdida de energía. El tales como anti-passback, verificación multi-usuario,
controlador continúa operando aún si se interrumpe la huella y contraseña de coacción, vínculos con entradas
conexión de red. y salidas auxiliares, entre otras.

Costo Total más Bajo


El firmware del controlador puede ser actualizado.
Las nuevas características del controlador se pueden
cargar para extender y ampliar el valor de su inversión
sin necesidad de herramientas avanzadas.

Especificaciones
(GL caracteristica exclusiva) InBio-160 Pro InBio-260 Pro InBio-460 Pro
Número de Puertas 1 Puerta 2 Puerta 4 Puerta

Número de Lectores Soportados 4 (2 RS-485, 2 Wiegand 26-bits) 8 (4 RS-485, 4 Wiegand 26-bits) 12 (8 RS-485, 4 Wiegand 26-bits)

Tipos de Lectores Wiegand 26-bits y Wiegand 26-bits y Wiegand 26-bits y


Soportados Lectores RS485 Serie FR Lectores RS485 Serie FR Lectores RS485 Serie FR
Número de Entradas 3 (1Botón de Salida, 1 Sensor de 6 (2 Botones de Salida, 2 Sensores de 12 (4 Botones de Salida, 4 Sensores de
Puerta, 1 Auxiliar) Puerta, 2 Auxiliares) Puerta, 4 Auxiliares)
Número de Salidas 2 (1 Relevador C para Chapa y 1 4 (2 Relevadores C para Chapa y 2 8 (4 Relevadores C para Chapa y 4
Relevador C para Salida Auxiliar) Relevadores C para Salida Auxiliar) Relevadores C para Salida Auxiliar)
Capacidad de Tarjetas 60.000 60.000 60.000

Capacidad de Huellas 20.000 20.000 20.000

Capacidad de Eventos 100.000 100.000 100.000

Comunicación TCP/IP TCP/IP TCP/IP

Dimensión con Gabinete 350 × 90 × 300 mm 350 × 90 × 300 mm 350 × 90 × 300 mm

Peso con Gabinete 3.6kg 3.6kg 3.7kg

Dimensión del Panel 184 × 35 × 105 mm 184 × 35 × 105 mm 225 × 38 × 105 mm

CPU 32 bit 1.2 GHz CPU 32 bit 1.2 GHz CPU 32 bit 1.2 GHz CPU

RAM 128MB 128MB 128MB

Memoria Flash 256MB 256MB 256MB

Fuente de Alimentación 9.6V-14.4V DC 9.6V-14.4V DC 9.6V-14.4V DC


Temperatura de Operación 0-45 °C 0-45 °C 0-45 °C
Humedad de Operación 20% a 80% 20% a80% 20% a 80%
InBio-160/260/460 Pro Paquete B*

Dispositivo Descripción Cantidad


InBio160/260/460 Pro Panel de Control 1

Case01 Gabinete Metálico 1

Fuente de Poder, DC12V/2A,


ZKPSM030B 1
Disponible para la Batería de Respaldo

FR107 Diodo para Cerradura 1

Llave Llave para Gabinete Metálico 2

Guía de Instalación 1

Peso 3.6-3.7kg

Dimensiones 350 × 90 × 300 mm

*Este paquete según la región también puede encontrarse como “Pro Box”

Instalación

No Touch

EXIT

Botón de Salida
ZKBioSecurity

TCP/IP TCP/IP
Serie - InBio Pro
KR602E
PC
GLED

GLED

GLED

GLED
BEEP

BEEP

BEEP

BEEP
485+
GND

GND

GND

GND

GND
+12V

485-

PWR

GND

GND

GND

GND

GND

GND

GND

GND
GRD
RUN

WD0

WD0

WD0

WD0
+12V

+12V

+12V

+12V
WD1

WD1

WD1

WD1
ACT
IN

IN

IN

IN

IN

IN

IN

IN

AUX 1 AUX 2 AUX 3 AUX4 EXT STATE BUTTON 1 READER 1 BUTTON 2 READER 2 BUTTON 3 READER 3 BUTTON 4 READER 4

EXT PC CARD RUN POWER


RS485 RS485

A d va nc ed A c c es s C ontrol

Entrada Auxiliar LAN SWITCH PC AUXOUT1 AUXOUT2 AUXOUT3 AUXOUT4 LOCK1 LOCK2 LOCK3 LOCK4 LOCK POWER

Salida Auxiliar
SGND
485+

COM

COM

COM

COM

COM

COM

COM

COM
GND

GND

GND

GND

GND
+12V
485-

SEN

SEN

SEN

SEN
NO

NO

NO

NO

NO

NO

NO

NO
NC

NC

NC

NC

NC

NC

NC

NC

V+
V-
RS485

Sensor de Puerta Sensor de Puerta Sensor de Puerta Sensor de Puerta


Cerradura Eléctrica

Cerradura Eléctrica

Cerradura Eléctrica

Cerradura Eléctrica

FR1500 FR1500 FR1500 FR1500 FR1500 FR1500 FR1500 FR1500

Firmado electrónicamente por:

JUAN PABLO
CORREA

Derechos de Autor © 2017, ZKTeco CO., LTD. Todos los derechos reservados.