Mech Eng Ds
Mech Eng Ds
DS RELAYS
9.9
15
9.9
TYPICAL APPLICATIONS
Telecommunications
Measurement equipment
OA equipment
Information related equipment
Industrial machines
(Unit:mm)
ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)
AG 2 1 44
ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)
DS 1 E
TYPES
" Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market.
PC board terminal
Standard type (M): Carton
Contact Rated coil Single side stable 2 coil latching Standard packing
arrangement voltage Type No. Part No. Type No. Part No. Inner carton Outer carton
1.5 V DC DS1E-M-DC1.5V AG201044 DS1E-ML2-DC1.5V AG221044
3 V DC DS1E-M-DC3V AG201144 DS1E-ML2-DC3V AG221144
5 V DC DS1E-M-DC5V AG201944 DS1E-ML2-DC5V AG221944
6 V DC DS1E-M-DC6V AG201244 DS1E-ML2-DC6V AG221244
1 Form C 50 pcs. 500 pcs.
9 V DC DS1E-M-DC9V AG201744 DS1E-ML2-DC9V AG221744
12 V DC DS1E-M-DC12V AG201344 DS1E-ML2-DC12V AG221344
24 V DC DS1E-M-DC24V AG201444 DS1E-ML2-DC24V AG221444
48 V DC DS1E-M-DC48V AG201544 DS1E-ML2-DC48V AG221544
RATING
Coil data
• Operating characteristics such as “Operate voltage” and “Release voltage” are influenced by mounting conditions or ambient
temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• “Initial” means the condition of products at the time of delivery.
Single side stable
Rated operating Max. allowable
Rated coil Operate voltage* Release voltage* Coil resistance Rated operating
Type current voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C) power
(±10%, at 20°C) (at 50°C)
1.5 V DC 266.7 mA 5.63 Ω
3 V DC 133.3 mA 22.5 Ω
Standard type (M)
5 V DC 80 mA 62.5 Ω
6 V DC Max. 70% V of Min. 10% V of 66.7 mA 90 Ω 120% V of
rated coil voltage rated coil voltage 400 mW
9 V DC 44.4 mA 203 Ω rated coil voltage
(Initial) (Initial)
12 V DC 33.3 mA 360 Ω
24 V DC 16.7 mA 1,440 Ω
48 V DC 8.3 mA 5,760 Ω
1.5 V DC 133.3 mA 11.3 Ω
High sensitive type (S)
3 V DC 66.7 mA 45 Ω
5 V DC 40 mA 125 Ω
6 V DC Max. 80% V of Min. 10% V of 33.3 mA 180 Ω 160% V of
rated coil voltage rated coil voltage 200 mW
9 V DC 22.2 mA 405 Ω rated coil voltage
(Initial) (Initial)
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω
48 V DC 4.2 mA 11,520 Ω
*square, pulse drive (JIS C 5442)
2 coil latching
Rated operating
Coil resistance Rated operating Max. allowable
Rated coil Set voltage* Reset voltage* current
Type (±10%, at 20°C) power voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C)
(at 50°C)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5 V DC 240 mA 240 mA 6.25 Ω 6.25 Ω
3 V DC 120 mA 120 mA 25 Ω 25 Ω
Standard type (M)
5 V DC 72 mA 72 mA 69.4 Ω 69.4 Ω
6 V DC Max. 70% V of Max. 70% V of 60 mA 60 mA 100 Ω 100 Ω 120% V of
rated coil voltage rated coil voltage 360 mW 360 mW
9 V DC 40 mA 40 mA 225 Ω 225 Ω rated coil voltage
(Initial) (Initial)
12 V DC 30 mA 30 mA 400 Ω 400 Ω
24 V DC 15 mA 15 mA 1,600 Ω 1,600 Ω
48 V DC 7.5 mA 7.5 mA 6,400 Ω 6,400 Ω
1.5 V DC 120 mA 120 mA 12.5 Ω 12.5 Ω
High sensitive type (S)
3 V DC 60 mA 60 mA 50 Ω 50 Ω
5 V DC 36 mA 36 mA 139 Ω 139 Ω
6 V DC Max. 80% V of Max. 80% V of 30 mA 30 mA 200 Ω 200 Ω 160% V of
rated coil voltage rated coil voltage 180 mW 180 mW
9 V DC 20 mA 20 mA 450 Ω 450 Ω rated coil voltage
(Initial) (Initial)
12 V DC 15 mA 15 mA 800 Ω 800 Ω
24 V DC 7.5 mA 7.5 mA 3,200 Ω 3,200 Ω
48 V DC 3.75 mA 3.75 mA 12,800 Ω 12,800 Ω
*square, pulse drive (JIS C 5442)
Electrical life
Conditions: Resistive load, at 60 times/min.
Type Switching capacity Number of operations
1 Form C 2 A 30 V DC Min. 500 x 103
REFERENCE DATA
1. Max. switching capacity 2. Switching life curve 3. Coil temperature rise value (High
sensitive Single side stable)
Tested sample:AG231344 5 pcs.
Point measured:Inside the Coil
Contact current:0A, 2A, 3A
Ambient temperature:25° C
1,000 80
70 3A
Contact current
2A
Temperature rise, °
C
60
30V DC resistive load
1A 100
50
40
DC resistive load
100mA 125V AC resistive load 30
10
20
10
10μA 0 0
10mV 10V 100V 1,000V 0 1 2 0 100 120 140 160 180
Contact voltage, DC Switching capacity, A Coil applied voltage, %V
4. Mechanical life (High sensitivity Single 5. Influence of proximity mounting 6. Contact reliability test
side stable)
Tested sample:AG231344 6 pcs. Operating speed:20 cpm.
Operating speed:1,800 cpm. Detection level:200 mΩ
100 20 99.9
Rate of change, %
(1()2(
)3)
99 Weibull
Ratio against the rated voltage, %V
10 OFF OFF
90 95 probability
Operate voltage Ave. data
80 70
0 ℓ ℓ
Operate voltage 50
70 ON ON
Max. 30
60 -10 F t), %
0.5A
-20 ℓ ℓ 10
(
50 Min. 250V AC
20
Rate of change, %
OFF OFF 5 1A
40 10 125V AC
2
30 Release voltage Release voltage Ave. ℓ ℓ
0 1
Max. 0.5A
20 ON ON
0.5 125V AC
10 -10 0.2 0.3A
Min. ℓ ℓ 250V AC
0 -20 0.1
1 10 100 1,000 10,000 5 10 0 10 100 1,000
No. of operations, ×104 Inter-relay distance, ℓ mm No. of operations, ×104
DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Unit: mm
2.54
9.9
1 6
+ -
7.62
12 10 7
5.08 7.62
9.9
General tolerance:±0.1
0.6
3.4
2.54
7.62
1 3 6
+ +
General tolerance : ±0.3 -
7.62
12 10 7
5.08 7.62
General tolerance:±0.1
SAFETY STANDARDS Each standard may be updated at any time, so please check our Website for the latest information.
or cautions for use, please read “GUIDELINES FOR SIGNAL RELAYS USAGE” and “GUIDELINES FOR RELAY
F
USAGE”.
For cautions for use, please read "GUIDELINES FOR RELAY USAGE".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
Long term current carrying Maximum allowable voltage and temperature rise
A circuit that will be carrying a current continuously for Proper usage requires that the rated coil voltage be impressed
long periods without relay switching operation. (circuits for on the coil.
emergency lamps, alarm devices and error inspection that, for Note, however, that if a voltage greater than or equal to the
example, revert only during malfunction and output warnings maximum continuous voltage is impressed on the coil, the coil
with form B contacts) may burn or its layers short due to the temperature rise.
Continuous,long-term current to the coil will facilitate Furthermore, do not exceed the usable ambient temperature
deterioration of coil insulation and characteristics due to range listed in the catalog.
heating of the coil itself. For circuits such as these, please use Temperature rise due to pulse voltage
a magnetic-hold type latching relay. If you need to use a single When a pulse voltage with ON time of less than 2 minutes is
stable relay, use a sealed type relay that is not easily affected used, the coil temperature rise bares no relationship to the ON
by ambient conditions and make a failsafe circuit design that time.
considers the possibility of contact failure or disconnection. This varies with the ratio of ON time to OFF time, and
compared with continuous current passage, it is rather small.
DC Coil operating power The various relays are essentially the same in this respect.
Steady state DC current should be applied to the coil.
The wave form should be rectangular. If it includes ripple, the Current passage time %
ripple factor should be less than 5%. However, please check For continuous passage Temperature rise value is 100%
with the actual circuit since the electrical characteristics may ON : OFF = 3 : 1 About 80%
vary. ON : OFF = 1 : 1 About 50%
The rated coil voltage should be applied to the coil and the ON : OFF = 1 : 3 About 35%
set/reset pulse time of latching type relay differs for each
relays, please refer to the relay's individual specifications. ON : OFF = 1 : 1
Voltage
Coil connection
When connecting coils of polarized relays, please check coil
polarity(+,-) at the internal connection diagram (Schematic).
Time
If any wrong connection is made, it may cause unexpected
malfunction, like abnormal heat, fire and so on, and circuit do Operate voltage change due to coil temperature rise (hot start)
not work. In DC relays, after continuous passage of current in the coil, if
Avoid impressing voltages to the set coil and reset coil at the the current is turned OFF, then immediately turned ON again,
same time. due to the temperature rise in the coil, the operate voltage will
become somewhat higher. Also, it will be the same as using it
in a higher temperature atmosphere.
The resistance/temperature relationship for copper wire is
about 0.4% for 1°C, and with this ratio the coil resistance
increases.
That is, in order to operate of the relay, it is necessary that the
voltage be higher than the operate voltage and the operate
voltage rises in accordance with the increase in the resistance
value.
However, for some polarized relays, this rate of change is
considerably smaller.
NOTES
OTHERS
Cleaning
1) Although the environmentally sealed type relay (plastic sealed 3) Cleaning with the boiling method is recommended (The
type,etc.) can be cleaned, avoid immersing the relay into cold temperature of cleaning liquid should be 40°C or lower). Avoid
liquid (such as cleaning solvent) immediately after soldering. ultrasonic cleaning on relays.
Doing so may deteriorate the sealing performance. Use of ultrasonic cleaning may cause breaks in the coil or
2) Surface-mount terminal type relay is sealed type and it can be slight sticking of the contacts due to the ultrasonic energy.
cleaned by immersion.
Use pure water or alcohol-based cleaning solvent.