0% found this document useful (0 votes)
97 views11 pages

Mech Eng Ds

This document provides information about signal relays rated at 2A or less, including: - High sensitivity 200mW rated operating power relays with 1 Form C contact arrangement and sealed protective construction. - Standard and high sensitivity types are available with single side stable or 2 coil latching operating functions. - Rated coil voltages range from 1.5V to 48V DC. - Technical specifications include operate/release voltages, coil resistance, rated operating current, and maximum allowable voltage. - Ordering part numbers and standard packaging quantities are provided for both Japanese and non-Japanese markets.

Uploaded by

路人丁
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views11 pages

Mech Eng Ds

This document provides information about signal relays rated at 2A or less, including: - High sensitivity 200mW rated operating power relays with 1 Form C contact arrangement and sealed protective construction. - Standard and high sensitivity types are available with single side stable or 2 coil latching operating functions. - Rated coil voltages range from 1.5V to 48V DC. - Technical specifications include operate/release voltages, coil resistance, rated operating current, and maximum allowable voltage. - Ordering part numbers and standard packaging quantities are provided for both Japanese and non-Japanese markets.

Uploaded by

路人丁
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Signal Relays (2A or less)

DS RELAYS

High sensitivity 200 mW Rated operating power, 1 Form C, 2A relays

Protective construction:Sealed type FEATURES


High sensitivity: 200 mW rated operating power
(High sensitivity type, single side stable)

9.9
15

9.9
TYPICAL APPLICATIONS
Telecommunications
Measurement equipment
OA equipment
Information related equipment
Industrial machines

(Unit:mm)

ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)

AG 2 1 44

Type / Operating function Contact arrangement Rated coil voltage (DC)


0:Standard type Single side stable 1 : 1 Form C 0 : 1.5 V, 1 : 3 V, 2 : 6 V, 3 : 12 V,
2:Standard type 2 coil latching 4 : 24 V, 5 : 48 V, 7 : 9 V, 9:5V
3:High sensitivity type Single side stable
5:High sensitivity type 2 coil latching

ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)

DS 1 E

Contact arrangement Type Operating function Rated coil voltage(DC)


1 : 1 Form C M : Standard type Nil:Single side stable 1.5, 3, 5, 6, 9, 12, 24, 48 V
S : High sensitivity type L2 :2 coil latching

2021.05 industrial.panasonic.com/ac/e/ ー1ー Panasonic Corporation 2021 ASCTB17E 202105


Signal Relays (2A or less) DS RELAYS

TYPES

" Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market.

PC board terminal
Standard type (M): Carton
Contact Rated coil Single side stable 2 coil latching Standard packing
arrangement voltage Type No. Part No. Type No. Part No. Inner carton Outer carton
1.5 V DC DS1E-M-DC1.5V AG201044 DS1E-ML2-DC1.5V AG221044
3 V DC DS1E-M-DC3V AG201144 DS1E-ML2-DC3V AG221144
5 V DC DS1E-M-DC5V AG201944 DS1E-ML2-DC5V AG221944
6 V DC DS1E-M-DC6V AG201244 DS1E-ML2-DC6V AG221244
1 Form C 50 pcs. 500 pcs.
9 V DC DS1E-M-DC9V AG201744 DS1E-ML2-DC9V AG221744
12 V DC DS1E-M-DC12V AG201344 DS1E-ML2-DC12V AG221344
24 V DC DS1E-M-DC24V AG201444 DS1E-ML2-DC24V AG221444
48 V DC DS1E-M-DC48V AG201544 DS1E-ML2-DC48V AG221544

High sensitivity type (S): Carton


Contact Rated coil Single side stable 2 coil latching Standard packing
arrangement voltage Type No. Part No. Type No. Part No. Inner carton Outer carton
1.5 V DC DS1E-S-DC1.5V AG231044 DS1E-SL2-DC1.5V AG251044
3 V DC DS1E-S-DC3V AG231144 DS1E-SL2-DC3V AG251144
5 V DC DS1E-S-DC5V AG231944 DS1E-SL2-DC5V AG251944
6 V DC DS1E-S-DC6V AG231244 DS1E-SL2-DC6V AG251244
1 Form C 50 pcs. 500 pcs.
9 V DC DS1E-S-DC9V AG231744 DS1E-SL2-DC9V AG251744
12 V DC DS1E-S-DC12V AG231344 DS1E-SL2-DC12V AG251344
24 V DC DS1E-S-DC24V AG231444 DS1E-SL2-DC24V AG251444
48 V DC DS1E-S-DC48V AG231544 DS1E-SL2-DC48V AG251544

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー2ー Panasonic Corporation 2021 ASCTB17E 202105
Signal Relays (2A or less) DS RELAYS

RATING

Coil data
• Operating characteristics such as “Operate voltage” and “Release voltage” are influenced by mounting conditions or ambient
temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• “Initial” means the condition of products at the time of delivery.
Single side stable
Rated operating Max. allowable
Rated coil Operate voltage* Release voltage* Coil resistance Rated operating
Type current voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C) power
(±10%, at 20°C) (at 50°C)
1.5 V DC 266.7 mA 5.63 Ω
3 V DC 133.3 mA 22.5 Ω
Standard type (M)

5 V DC 80 mA 62.5 Ω
6 V DC Max. 70% V of Min. 10% V of 66.7 mA 90 Ω 120% V of
rated coil voltage rated coil voltage 400 mW
9 V DC 44.4 mA 203 Ω rated coil voltage
(Initial) (Initial)
12 V DC 33.3 mA 360 Ω
24 V DC 16.7 mA 1,440 Ω
48 V DC 8.3 mA 5,760 Ω
1.5 V DC 133.3 mA 11.3 Ω
High sensitive type (S)

3 V DC 66.7 mA 45 Ω
5 V DC 40 mA 125 Ω
6 V DC Max. 80% V of Min. 10% V of 33.3 mA 180 Ω 160% V of
rated coil voltage rated coil voltage 200 mW
9 V DC 22.2 mA 405 Ω rated coil voltage
(Initial) (Initial)
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω
48 V DC 4.2 mA 11,520 Ω
*square, pulse drive (JIS C 5442)

2 coil latching
Rated operating
Coil resistance Rated operating Max. allowable
Rated coil Set voltage* Reset voltage* current
Type (±10%, at 20°C) power voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C)
(at 50°C)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5 V DC 240 mA 240 mA 6.25 Ω 6.25 Ω
3 V DC 120 mA 120 mA 25 Ω 25 Ω
Standard type (M)

5 V DC 72 mA 72 mA 69.4 Ω 69.4 Ω
6 V DC Max. 70% V of Max. 70% V of 60 mA 60 mA 100 Ω 100 Ω 120% V of
rated coil voltage rated coil voltage 360 mW 360 mW
9 V DC 40 mA 40 mA 225 Ω 225 Ω rated coil voltage
(Initial) (Initial)
12 V DC 30 mA 30 mA 400 Ω 400 Ω
24 V DC 15 mA 15 mA 1,600 Ω 1,600 Ω
48 V DC 7.5 mA 7.5 mA 6,400 Ω 6,400 Ω
1.5 V DC 120 mA 120 mA 12.5 Ω 12.5 Ω
High sensitive type (S)

3 V DC 60 mA 60 mA 50 Ω 50 Ω
5 V DC 36 mA 36 mA 139 Ω 139 Ω
6 V DC Max. 80% V of Max. 80% V of 30 mA 30 mA 200 Ω 200 Ω 160% V of
rated coil voltage rated coil voltage 180 mW 180 mW
9 V DC 20 mA 20 mA 450 Ω 450 Ω rated coil voltage
(Initial) (Initial)
12 V DC 15 mA 15 mA 800 Ω 800 Ω
24 V DC 7.5 mA 7.5 mA 3,200 Ω 3,200 Ω
48 V DC 3.75 mA 3.75 mA 12,800 Ω 12,800 Ω
*square, pulse drive (JIS C 5442)

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー3ー Panasonic Corporation 2021 ASCTB17E 202105
Signal Relays (2A or less) DS RELAYS
Specifications
Item Specifications
Contact arrangement 1 Form C
Contact resistance
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
(initial)
Contact material Ag+Au clad
Contact rating
2 A 30 V DC
(resistive)
Contact data
Max. switching power
60 W, 125 VA
(resistive)
Max. switching voltage 220 V DC, 250 V AC
Max. switching current 3A
Min. switching load
10 μA 10 mV DC
(reference value)*1
Insulation resistance (initial) Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Standard type (M):
1,000 Vrms for 1 min (detection current: 10 mA)
Between open contacts
High sensitive type (S):
Dielectric 500 Vrms for 1 min (detection current: 10 mA)
strength (initial) Standard type (M):
Between contact and 1,500 Vrms for 1 min (detection current: 10 mA)
coil High sensitive type (S):
1,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (at 20°C, without bounce)
Time Operate [Set] time
[Max. 10 ms (at 20°C, without bounce)]
characteristics
(initial) Max. 5 ms at rated coil voltage (at 20°C, without bounce, without diode)
Release [Reset] time
[Max. 10 ms (at 20°C, without bounce)]
Shock Functional 490 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
resistance Destructive 980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Functional 10 to 55 Hz (at double amplitude of: 3.3 mm, detection time: 10 μs)
resistance Destructive 10 to 55 Hz (at double amplitude of: 5 mm)
Single side stable: Min. 100 x 106
Expected life Mechanical life
Latching: Min. 10 x 106 (at 600 times/min)
Conditions for usage, Ambient temperature: –40 to +70°C
Conditions
transport and storage*2 Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 3 g
*1. This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
TX/TX-S/TX-D relay AgPd contact type are available for low level load analog circuit (10 V DC, 10 mA max. level).
*2. For ambient temperature, please refer to the “GUIDELINES FOR RELAY USAGE”.

Electrical life
Conditions: Resistive load, at 60 times/min.
Type Switching capacity Number of operations
1 Form C 2 A 30 V DC Min. 500 x 103

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー4ー Panasonic Corporation 2021 ASCTB17E 202105
Signal Relays (2A or less) DS RELAYS

REFERENCE DATA

1. Max. switching capacity 2. Switching life curve 3. Coil temperature rise value (High
sensitive Single side stable)
Tested sample:AG231344 5 pcs.
Point measured:Inside the Coil
Contact current:0A, 2A, 3A
Ambient temperature:25° C
1,000 80

70 3A
Contact current

2A

No. of operations, ×104


0A

Temperature rise, °
C
60
30V DC resistive load
1A 100
50

40
DC resistive load
100mA 125V AC resistive load 30
10
20

10

10μA 0 0
10mV 10V 100V 1,000V 0 1 2 0 100 120 140 160 180
Contact voltage, DC Switching capacity, A Coil applied voltage, %V

4. Mechanical life (High sensitivity Single 5. Influence of proximity mounting 6. Contact reliability test
side stable)
Tested sample:AG231344 6 pcs. Operating speed:20 cpm.
Operating speed:1,800 cpm. Detection level:200 mΩ

100 20 99.9
Rate of change, %

(1()2(
)3)
99 Weibull
Ratio against the rated voltage, %V

10 OFF OFF
90 95 probability
Operate voltage Ave. data
80 70
0 ℓ ℓ
Operate voltage 50
70 ON ON
Max. 30
60 -10 F t), %
0.5A
-20 ℓ ℓ 10

50 Min. 250V AC
20
Rate of change, %

OFF OFF 5 1A
40 10 125V AC
2
30 Release voltage Release voltage Ave. ℓ ℓ
0 1
Max. 0.5A
20 ON ON
0.5 125V AC
10 -10 0.2 0.3A
Min. ℓ ℓ 250V AC
0 -20 0.1
1 10 100 1,000 10,000 5 10 0 10 100 1,000
No. of operations, ×104 Inter-relay distance, ℓ mm No. of operations, ×104

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー5ー Panasonic Corporation 2021 ASCTB17E 202105
Signal Relays (2A or less) DS RELAYS

DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Unit: mm

Single side stable/2 coil latching


CAD External dimensions Suggested PC board pattern Schematic
(BOTTOM VIEW) (BOTTOM VIEW)
15.0
Single side stable Single side stable
2.54 5-0.9 dia. (Deenergized condition)

2.54
9.9

1 6
+ -

7.62
12 10 7

5.08 7.62
9.9

General tolerance:±0.1
0.6
3.4

2 coil latching 2 coil latching


0.3
0.6 5.6 2.54 6-0.9 dia. (Reset condition)
1.15 5.08 7.62

2.54
7.62
1 3 6
+ +
General tolerance : ±0.3 -

7.62
12 10 7

5.08 7.62

General tolerance:±0.1

SAFETY STANDARDS Each standard may be updated at any time, so please check our Website for the latest information.

UL (Recognized) CSA (Certified)


Ambient Ambient
File No. Contact rating Operations File No. Contact rating (Certified) Operations
temperature temperature
2 A 30 V DC Resistive 100 × 103 40°C 2 A 30 V DC 100 × 103 40°C
LR26550
E43149 0.6 A 110 V DC Resistive 100 × 103 40°C 0.6 A 110 V DC 100 × 103 40°C
etc.
0.6 A 125 V AC General use 100 × 103 40°C 0.6 A 125 V AC 100 × 103 40°C

GUIDELINES FOR USAGE

 or cautions for use, please read “GUIDELINES FOR SIGNAL RELAYS USAGE” and “GUIDELINES FOR RELAY
F
USAGE”.

Cautions for usage of DS relay


Latching
• Use latching when conditions involve continuous carrying
current.
• Regarding the set and reset pulse time, for the purpose of
reliable operation under ambient temperature fluctuations and
different operating conditions, we recommend setting the coil
applied set and reset pulse time to 10 ms or more at the rated
coil voltage.
• The relay is shipped in the reset position. But jolts during
transport or impacts during installation can change the reset
position. It is, therefore, advisable to build a circuit in which the
relay can be initialized (set and reset) just after turning on the
power.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー6ー Panasonic Corporation 2021 ASCTB17E 202105
GUIDELINES FOR SIGNAL RELAYS USAGE

For cautions for use, please read "GUIDELINES FOR RELAY USAGE".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp

PRECAUTIONS FOR COIL INPUT

Long term current carrying Maximum allowable voltage and temperature rise
A circuit that will be carrying a current continuously for Proper usage requires that the rated coil voltage be impressed
long periods without relay switching operation. (circuits for on the coil.
emergency lamps, alarm devices and error inspection that, for Note, however, that if a voltage greater than or equal to the
example, revert only during malfunction and output warnings maximum continuous voltage is impressed on the coil, the coil
with form B contacts) may burn or its layers short due to the temperature rise.
Continuous,long-term current to the coil will facilitate Furthermore, do not exceed the usable ambient temperature
deterioration of coil insulation and characteristics due to range listed in the catalog.
heating of the coil itself. For circuits such as these, please use Temperature rise due to pulse voltage
a magnetic-hold type latching relay. If you need to use a single When a pulse voltage with ON time of less than 2 minutes is
stable relay, use a sealed type relay that is not easily affected used, the coil temperature rise bares no relationship to the ON
by ambient conditions and make a failsafe circuit design that time.
considers the possibility of contact failure or disconnection. This varies with the ratio of ON time to OFF time, and
compared with continuous current passage, it is rather small.
DC Coil operating power The various relays are essentially the same in this respect.
Steady state DC current should be applied to the coil.
The wave form should be rectangular. If it includes ripple, the Current passage time %
ripple factor should be less than 5%. However, please check For continuous passage Temperature rise value is 100%
with the actual circuit since the electrical characteristics may ON : OFF = 3 : 1 About 80%
vary. ON : OFF = 1 : 1 About 50%
The rated coil voltage should be applied to the coil and the ON : OFF = 1 : 3 About 35%
set/reset pulse time of latching type relay differs for each
relays, please refer to the relay's individual specifications. ON : OFF = 1 : 1
Voltage

Coil connection
When connecting coils of polarized relays, please check coil
polarity(+,-) at the internal connection diagram (Schematic).
Time
If any wrong connection is made, it may cause unexpected
malfunction, like abnormal heat, fire and so on, and circuit do Operate voltage change due to coil temperature rise (hot start)
not work. In DC relays, after continuous passage of current in the coil, if
Avoid impressing voltages to the set coil and reset coil at the the current is turned OFF, then immediately turned ON again,
same time. due to the temperature rise in the coil, the operate voltage will
become somewhat higher. Also, it will be the same as using it
in a higher temperature atmosphere.
The resistance/temperature relationship for copper wire is
about 0.4% for 1°C, and with this ratio the coil resistance
increases.
That is, in order to operate of the relay, it is necessary that the
voltage be higher than the operate voltage and the operate
voltage rises in accordance with the increase in the resistance
value.
However, for some polarized relays, this rate of change is
considerably smaller.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー7ー Panasonic Corporation 2021 ASCTB414E 202104
GUIDELINES FOR RELAY USAGE

NOTES

Usage, Storage, and Transport Conditions Condensation


During usage, storage, or transportation, avoid locations Condensation occurs when the ambient temperature drops
subject to direct sunlight and maintain normal temperature, suddenly from a high temperature and humidity, or the relay
humidity, and pressure conditions. and microwave device is suddenly transferred from a low
The allowable specifications for environments suitable for ambient temperature to a high temperature and humidity.
usage, storage, and transportation are given below. Condensation causes the failures like insulation deterioration,
1) Temperature: The allowable temperature range differs for wire disconnection and rust etc.
each relay, so refer to the relay’s individual specifications. Panasonic Corporation does not guarantee the failures caused
In addition, when transporting or storing relays while they are by condensation.
tube packaged, there are cases when the temperature may The heat conduction by the equipment may accelerate the
differ from the allowable range. In this situation, be sure to cooling of device itself, and the condensation may occur.
consult the individual specifications. Please conduct product evaluations in the worst condition of
2) Humidity: 5 to 85% RH the actual usage. (Special attention should be paid when high
The humidity range varies with the temperature. temperature heating parts are close to the device. Also please
Use within the range indicated in the graph.
(The allowable temperature depends on the relays.) consider the condensation may occur inside of the device.)
Icing
Humidity (% RH)
Condensation or other moisture may freeze on relays when
the temperature become lower than 0°C.
85 This icing causes the sticking of movable portion, the operation
delay and the contact conduction failure etc.
Allowable range Panasonic Corporation does not guarantee the failures caused
Avoid icing Avoid con- by the icing.
when used at densation when The heat conduction by the equipment may accelerate the
temperatures used at tem-
lower than 0°C peratures higher cooling of relay itself and the icing may occur.
than 0°C
5 Please conduct product evaluations in the worst condition of
-40 0 85 the actual usage.
Ambient temperature (℃) Low temperature and low humidity
The plastic becomes brittle if the switch is exposed to a low
3) Pressure: 86 to 106 kPa
temperature, low humidity environment for long periods of
time.
High temperature and high humidity
Storage for extended periods of time (including transportation
periods) at high temperature or high humidity levels or in
atmospheres with organic gases or sulfide gases may cause a
sulfide film or oxide film to form on the surfaces of the contacts
and/or it may interfere with the functions.
Check out the atmosphere in which the units are to be stored
and transported.
Package
In terms of the packing format used, make every effort to keep
the effects of moisture, organic gases and sulfide gases to the
absolute minimum.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー8ー Panasonic Corporation 2021 ASCTB414E 202104
GUIDELINES FOR RELAY USAGE
Storage requirements 4) The following cautionary label is affixed to the anti-humidity
Since the surface-mount terminal type is sensitive to humidity pack.
it is packaged with tightly sealed anti-humidity packaging.
However, when storing, please be careful of the following.
1) Please use promptly once the anti-humidity pack is opened.
(within 72 hours, Max. 30°C / 70% RH).
If left with the pack open, the relay will absorb moisture which
will cause thermal stress when reflow mounting and thus
cause the case to expand. As a result, the seal may break.
2) If relays will not be used within 72 hours, please store relays
in a humidity controlled desiccator or in an anti-humidity bag
to which silica gel has been added.
* If the relay is to be soldered after it has been exposed to excessive humidity
atmosphere, cracks and leaks can occur.
Be sure to mount the relay under the required mounting conditions.
3) When relays (which is packaged with humidity indicator and
silica gel) meeting one of below criteria, please bake (dry)
Silicon
before use.
When a source of silicone substances (silicone rubber, silicone
When the storage conditions specified in 1) are exceeded.
oil,silicone coating materials and silicone filling materials
When humidity indicator is in Ⅲ or Ⅳ status according to
etc.) is used around the relay, the silicone gas (low molecular
judgement standard.
siloxane etc.) may be produced
This silicone gas may penetrate into the inside of the relay.
<How to judge>
When the relay is kept and used in this condition, silicone
Please check humidity indicator color and decide if baking is
compound may adhere to the relay contacts which may cause
necessary or not.
the contact failure.
● : indicate brown, ○ : Other than brown (blueish color) Do not use any sources of silicone gas around the relay
Bake treatment (Including plastic seal types).
5% 10% 60%
necessity judgment
NOx Generation
Ⅰ ● ● ● No need to bake
When relay is used in an atmosphere high in humidity to
Ⅱ ○ ● ● No need to bake
Ⅲ ○ ○ ● Need to bake switch a load which easily produces an arc, the NOx created
Ⅳ ○ ○ ○ Need to bake by the arc and the water absorbed from outside the relay
combine to produce nitric acid.
Spot This corrodes the internal metal parts and adversely affects
operation.
Avoid use at an ambient humidity of 85% RH or higher (at
20°C).
If use at high humidity is unavoidable, please contact our sales
5% 10% 60% representative.

Humidity indicator card

<Baking (Drying) conditions>


With reel : 45°C, 96 hours or more.

Without reel (including relay only) : 60°C, 35 hours or more.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー9ー Panasonic Corporation 2021 ASCTB414E 202104
GUIDELINES FOR RELAY USAGE

OTHERS

Cleaning
1) Although the environmentally sealed type relay (plastic sealed 3) Cleaning with the boiling method is recommended (The
type,etc.) can be cleaned, avoid immersing the relay into cold temperature of cleaning liquid should be 40°C or lower). Avoid
liquid (such as cleaning solvent) immediately after soldering. ultrasonic cleaning on relays.
Doing so may deteriorate the sealing performance. Use of ultrasonic cleaning may cause breaks in the coil or
2) Surface-mount terminal type relay is sealed type and it can be slight sticking of the contacts due to the ultrasonic energy.
cleaned by immersion.
Use pure water or alcohol-based cleaning solvent.

Please refer to "the latest product specifications"


when designing your product.
•Requests to customers:
https://industrial.panasonic.com/ac/e/salespolicies/

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー 10 ー Panasonic Corporation 2021 ASCTB414E 202104
Please contact ..........

Electromechanical Control Business Division


1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industral.panasonic.com/ac/e/

©Panasonic Corporation 2021

ASCTB17E 202105 Specifications are subject to change without notice.