MPR 45S
MPR 45S
The products in ‘‘ENTES Power Quality and Energy” group are designed to measure various
electrical parameters. With their communication features all measurements can be tracked
from a single monitoring center. Energy quality and efficiency analysis can be performed with
network analyzers in electrical distribution/transmission systems, such as industrial facilities
and buildings.
Network Analyzers
MPR-3X Series
MPR-4X Series
MPR-6X Series
MPR-5X Series
EPM-07 Series
NEW
MPR-4X Series New-Generation Network Analyzers
With their compact design and 45mm depth, MPR-4X series new
generation network analyzers occupy less space in the panels and
have a wide range of operating voltage (45-265 VAC/DC). In
addition up to 8 MB internal memory, they offer wide I/O solutions with
their replaceable modular structure based on customer requirements
and areas of application.
MPR-4X Series offer a wide range of analog and digital inputs/outputs
and relay outputs with their I/O modules.
us
Operating Hours
Real Time Clock
Outage Records
Harmonics 1-51st
Max., Min. Cos,
Voltage/Current
Dimensions / mm
Pulse Counter
Digital Output
I neutral
Relay Output
Pulse Output
Unbalances
Digital Input
Event Logs
AI mA/V
Memory
RS-485
AO mA
THD-V
THD-I
Alarm
Meter
Product Code AO V
96x96
MPR-45 * * * * * * * * *
96x96 8MB
MPR-45S * * * * * * *
MPR-46 96x96
* * * * * * * * * *
MPR-46S 96x96
* * * * * * * 8MB
*
96x96 8MB
MPR-47S * * * * * * * *
Modular structure Standard
11
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-4X Series
MEASURED PARAMETERS
Active Energy Import
Phase - Neutral Voltages (VLN) Neutral Currents (In) Active Power (P)
(kWh or Mwh)
Active Energy Export
Phase - Phase Voltages (VLL) Total Current (I) Reactive Power (Q)
(kWh or MWh)
Reactive Energy Capacitive
Average Phase-Neutral Voltage Power Factor (P.F) Apparent Power (S)
(kVArh or MVArh)
Reactive Energy Inductive
Average Phase-Phase Voltage Cos Total Active Power (P)
(kVArh or MVArh)
Max. Demand Frequency (Hz) Total Reactive Power (Q) Voltage/Current Unbalances
Phase Currents (IL) Max. / Min. Values Total Apparent Power (S)
MPR-45 / MPR-45S
MPR-46 / MPR-46S
MPR-47S
63
46
Current Measurement Power
Suply Power
AkımMeasurement
Current Ölçümü Suply
99
96
Modül
l1 l2 l3 l4
k1 l1 k2 l2 k3 l3 k4 l4 Power Suply
MPR-4X Series (3 Phase without neutral Aron connection) MPR-4X/7X Series (3 Phase neutral connection)
Current Measurement
Modules
L1 L2 L3 L4 N GND B A TR
V1 V2 V3 V4 N GND A B TR
12
Print Date: 03.2014
Power Quality and Energy
Network Analyzers (LCD)
MPR-4X Series
SPECIFICATIONS
MPR-45 MPR-45S MPR-46 MPR-46S MPR-47S
ENCLOSURE
Dimensions 96x96x45mm
Protection Class Terminals = IP20, Enclosure Protection Class = IP51
Display LCD, with backlight
MEASUREMENTS
VOLTAGE
Measurement Range 5 - 690 VAC (L-N) 5-400 VAC (L-L)
Measurement Range with Transformer 1-400.0kV Transformer Ratio: 1-5000
Accuracy 1
Input Impedance >1M Ω
Burden (Input Load) <0,5 VA
CURRENT
Nominal Current In : 5A / 1A
Minimum Current 5 mA
Measurement Range 50 mA - 6 A Accuracy: 0.5% ± 1 Digit
Measurement Range with Transformer 50 mA -10000 A
Burden 0,5 VA
Overload Current 1,2 In continuous
Short Time Overload (1s) 10xIn
POWER/ENERGY
Active Power Range: 0 - 1 GW,Accuracy: 0.5% ± 1 Digit
Reactive Power Range: 0 - 1 GVAr,Accuracy: 1% ± 1 Digit
Apparent Power Range: 0 - 1 GVA, Accuracy: 1% ± 1 Digit
Power Factor Range: ±1.00, Accuracy : ± 0,02
Active Energy Range: 0 - 99 999 999 kWh or MWh, Accuracy: 1% 1 class
Reactive Energy Range: 0 - 99 999 999 kVArh or MVArh, Accuracy : 2% class 2
Demand Period 1,2,5,10,15,20,30,60 minimum adjustable
Frequency 45-65 Hz
SUPPLY
45 - 265 VAC/DC
50/60 Hz
<5 VA
PULSE OUTPUT
Energy Pulse Output * Active Energy Output (1kVArh/pulse
(1kWh/pulse - 50MWh/pulse)
*Reactive Energy Output - 50MVArh/pulse)
* Max. 50 mA
* 1005..24 VDC
…2500 ms
Pulse Width
* Max. 30 VDC
MEMORY
*
Internal Memory Size - 8MB - 8MB
COMMUNICATION
Communication Interface/Protocol - RS-485 / MODBUS RTU - RS-485 / MODBUS RTU
Transfer Speed - 2400-115200 bps - 2400-115200 bps
AMBIENT CONDITIONS
0
Operating Temperature - 5 / +55 C
0
Storage Temperature - 25 / +70 C
Overvoltage Category III
Pollution Degree II
Ambient Humidity 90%
STANDARDS
Applied Security Standards EN 61557-12, EN 61326-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
EN 62053, EN 60068, EN 61010
CONNECTIONS
Mounting front panel mounting with Rear terminals
Connection Terminals screw terminal with socket
Connection Types 3 phase neutral, 3 phase, 3 phase (Aron)
13
Print Date: 03.2014