Ultrasonic Gas flowmeter

Remote Control
Viewer (option): Remotely controls and configures parameters,
various display menu of integrated flowrate, transient flowrate,
temperature and pressure level.
Features
Wider measurement range and high accuracy
Temperature automatic correction
Attachable to vertical piping
Integrated flow rate and instant flow rate
<Viewer>
(option) selectable output
Lineup (nominal diameter)
Convertor Spool piece
Specifications Nominal diameter: 40mm,50mm, 65mm, 80mm, 100mm, 125mm, 150mm
Model: SGF-200 Material: Metal parts: SGP, SS400 (Nickel plating)
Measurement method: Ultrasonic transit time method Sensor parts: aluminum alloy, epoxy resin
Applicable liquid: Air, Oxygen, Nitrogen, Gas (no corrosive gas) Seal parts: NBR
Measurement accuracy: +/- 2%RD (flow speed 1 ∼ 30m/s) Condition: Temperature range: 0 ∼ 60℃
+/-2cm/s (flow speed less than 1m/s) Pressure range: less than 1MPa
Flow range: 0 ∼ 30m/s Installation requirement : Upper stream side 10D, Lower stream side : 5D or more
Temperature measurement: Ultrasonic thermometer(Air only) (D is inner diameter)
Accuracy: +/-2 ℃ Viewer (* option)
Structure: Outdoor use (IP65 equivalent) Model
Material: ADC12 CV-200
Paint color: White ivory (Munsell 5Y8/1.5) Display
Ambient temperature: -10 ∼ +50 LCD: 16 characters x 2 lines, back light
Humidity: No dew condensation Contents: instant flow rate, cross section average flow speed, integrated flow rate(normal, reverse, differences),
Power supply: AC90 ∼ 250V (50/60Hz) temperature, pressure
DC24V +/-10% Operation: Parameter configuration
Power consumption: less than 7.5VA Output: Digital output: instant flow rate, integrated flow rate, temperature, pressure, alarm information
Weight: Approximately 1.6kg Serial interface: RS422 (Boudrate: 38400bps)
Output Accessory: Cable( max. 30m): 1 cable
Analog output : Contents: Instant flow rate (normal flow or reverse flow) *SGF-200 is under the control of viewer if the viewer option is selected.
Signal: DC4 ∼ 20mA
Load resistance : less than 600Ω Dimension
Time constant: 0 ∼ 120sec (1sec step)
Low-cut: 0 ∼ 10% (1% step)
Cable
(Nylon Flexible Tube)
Contact output: Contents: normal / reverse flow integrated pulse, Connection for external viewer
upper / lower limit alarming, (option)

anomaly signal, range over


Signal(x3): Open collector standard 30V, 0.25V
Pulse width: 1 msec or 50 msec
Low-cut: 0 ∼ 10% (1% step)
Digital output: Contents: instant flow rate, integrated flow rate, temperature,
pressure, alarm
Serial interface: RS422 (baudrate: 38400bps)
Input
Temperature input: Current input: DC4 ∼ 20mA (input resistance 200Ω) Cable clamp
Conversion standard: 0 ℃ Diameter

Pressure input : Current input: DC4 ∼ 20mA


Conversion standard: 101.325kPa(abs)
Display
LCD : 16 characters x 2 lines LED back right Connection for pressure sensor

Contents: instant flow rate, cross section average flow speed,


integrated flow rate(normal, reverse, differences),
temperature, pressure

Holes

Specification table for nominal diameter


Dimension (mm) Appox. weight Max. flow rate
Nominal Flange spec. Steel pipe spec. (including convertor) Flow rate
diameter(mm) Holes

CAUTION FOR SAFETY : Please read surely INSTRUCTION MANUAL before operating.
●Specification is subject to change without prior notice for improvement.