DC-9503E Loop Isolator Installation and Operation Manual Issue 1.04

The document describes a DC-9503E loop isolator device. It features isolation of short circuits and automatic restoration when cleared, with a maximum output current of 1A. It provides details on installation, connection, cabling, specifications, warnings and the manufacturer.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
226 views2 pages

DC-9503E Loop Isolator Installation and Operation Manual Issue 1.04

The document describes a DC-9503E loop isolator device. It features isolation of short circuits and automatic restoration when cleared, with a maximum output current of 1A. It provides details on installation, connection, cabling, specifications, warnings and the manufacturer.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DC-9503E

Loop Isolator

Features
 Isolation of short circuit, automatic restore when
short circuit is cleared. 2831-CPR-F2019
GST-0017-01
 Maximum output current is 1A.
 DIN-Rail mounted or Wall mounted. 18

 Standard: EN 54-17:2005

Description
In fire alarm system, such condition often occurs that
548n/05
partial short circuit of loop affects the whole system.
DC-9503E Loop Isolator(hereinafter referred to as the
Installation
isolator)can isolate the shorted circuit from the whole
system to ensure normal operation of other devices 1) Before installation, make sure the enclosure is in
good condition and markings are complete.
and help locate the devices in fault. After the short
2) The isolator can be mounted on a 35mm
circuit fault is cleared, those devices will be DIN-Rail as shown on Fig. 2.
re-introduced into the system. 3) The isolator can also be wall mounted by 4
The isolator is suitable for use in the loop of mounting screws as shown in Fig. 3. Mounting
addressable fire alarm system. space is 67mm.

Connection & Cabling


Terminals of the isolator are shown in Fig. 1.

Fig. 2

Fig.1
(I+, I-) IN & OUT: input signal loop, I+ is positive and I-
is negative.
O+, O-: output signal loop, O+ is positive and O- is
negative.
Recommended Wiring: 1.0mm2 or above twisted pair. Fig. 3
Wires should not be laid out in the same conduit or
raceway with Class 1 wires such as power cables, Application
high and low voltage distribution cables and so on.
System connection is shown in Fig. 4. Note: Terminals
of the isolator have polarities.

30310469 Issue 1.04


Material and Color of
ABS, white (RAL9016)
Enclosure
Compatible DIN-Rail 35mm DIN-Rails
Dimension (L×W×H) 78mm×45.3mm×28.5mm
Weight About 41.4g

Limited Warranty
GST warrants that the product will be free from defects
in design, materials and workmanship during the
warranty period. This warranty shall not apply to any
Fig. 4
product that is found to have been improperly installed
or used in any way not in accordance with the
Specification instructions supplied with the product. Anybody,
including the agents, distributors or employees, is not
Loop: 24VDC (16V - 28V)
Operating Voltage in the position to amend the contents of this warranty.
Power Limited
Please contact your local distributor for products not
Standby Current ≤ 0.15mA
covered by this warranty.
Action Current ≤ 1.5mA
Capacity Maximum 70 devices
Yellow, flashes in standby Product warnings and disclaimers
Indicator
state, steady in fault.
THESE PRODUCTS ARE INTENDED FOR SALE TO,
Wiring Two wire
AND INSTALLATION BY, AN EXPERIENCED
Maximum Line Voltage
28V SECURITY PROFESSIONAL. UTC FIRE &
( VMAX)
SECURITY CANNOT PROVIDE ANY ASSURANCE
Minimum Line Voltage
16V THAT ANY PERSON OR ENTITY BUYING ITS
( VMIN)
PRODUCTS, INCLUDING ANY “AUTHORIZED
Maximum Continuous
1A DEALER”, IS PROPERLY TRAINED OR
Current( IC MAX)
EXPERIENCED TO CORRECTLY INSTALL
Maximum Transient
Output Current( IS 5A SECURITY RELATED PRODUCTS.
MAX) For more information on warranty disclaimers and
Maximum Open product safety information, please check
11V
Voltage (VSO MAX) https://firesecurityproducts.com/policy/product-warnin
Minimum Open g/ or scan the following code:
8V
Voltage( VSO MIN)
Maximum Close
4V
Voltage( VSC MAX)
Minimum Close
1.4V
Current( VSC MIN)
Maximum Leakage
7.5mA
Current( IL MAX)
Max closed
0.15Ω
impedance ( ZC MAX)
Operating
-10°C - +55°C
Temperature
Relative Humidity ≤ 95%, non-condensing
Ingress Protection
IP30
Rating

This Data Sheet is subject to change without notice. Please contact GST for more information or questions.

Gulf Security Technology Co., Ltd.


No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 066004
Tel: +86 (0) 335 8502434 Fax: +86 (0) 335 8502532
[email protected] www.gst.com.cn

30310469 Issue 1.04

You might also like