UP STANDARD DETAIL REFERENCE DRAWINGS

DETAIL OF HEAVY WELDING BOSSES FOR THREADED CONNECTIONS AE-036175

N
AWAY AWAY
CONSTRUCTION-NOTES AND DETAILS FOR ISOMETRIC PIPING
INSULATION DETAILS FOR HOT PIPING
AD-036627
AA-036911

SHOP MATERIALS INSULATION DETAILS FOR COLD PIPING AA-036913

INSTALLATION OF JACK SCREWS FOR FLANGED JOINTS AC-036630

TOWARD TOWARD PT N.B.


NOTES
NO DESCRIPTION (INS) STOCK CODE QTY
1. MATERIAL SHOWN WITH A BROKEN LINE AND SPOOLS LISTED IN THE SAUDI ARAMCO
DOWN
PIPE FABRICATION LIST ARE NOT TO BE FURNISHED BY THE VENDOR.

2. PIPING DETAILS SHALL BE CUT AT ALL POINTS MARKED F.W. (FIELD WELD).

1 PIPE , CS API 5L-B-PSL2 , SMLS , BE , 10 PPPCPVSMBESTD5F 3.5 M 3. EACH FABRICATED SECTION SHALL BE CLEARLY MARKED WITH ITS CODE NUMBER.

STD , B36.10M , FBE INT COATED 4. UNLESS OTHERWISE NOTED. (A) ALL DIMENSIONS ARE TO C OR FACE OF FLANGES.

3 (B) BOLT HOLES ON FLANGES STRADDLE C . (C) WELDING ELBOWS ARE LONG RADIUS.

EL +102387 5. FABRICATION SHALL BE IN ACCORDANCE WITH SAUDI ARAMCO SPECIFICATION 01-SAMSS-10.


FITTINGS 6. GASKET ALLOWANCE

7. PIPING MATERIAL IS
2 WELDOLET , CS A105N , STD , BE , HDR/BRN 10X2 PLWC1B00STDB20K 1
, SP-97 , FBE INT COATED PIPE SIZE SCHEDULE SPECIFICATION

3 90 LR ELBOW , CS A234-WPB , SMLS , BE , 10 P9LC34SMBESTDE5 3 REFER MTO REFER MTO REFER MTO

STD , B16.9 , FBE INT COATED

11 FLANGES
10 GAS7 BLT9
STEM SOUTH 4 WN FLG , CS A105N , CL150 , FF , STD , 10 PFWC1B15FFSTD5V 4 8. WELDING STRESS RELIEF - YES NO
X
178 6 B16.5 , FBE INT COATED RADIOGRAPHY % 100% X-RAY SPOT X-RAY 01-SAMSS-10 SHOP FIELD

71 5 WN FLG , CS A105N , CL150 , FF , STD , 2 PFWC1B15FFSTD5V 1 9. TESTING SHOP HYDROSTATIC TEST - YES NO
THE SHOP HYDROSTATIC TEST SHALL BE CARRIED OUT ON PIECES HAVING ALL ENDS

237 FLG5 GAS7 BLT9 B16.5 , FBE INT COATED FLANGED.

10. ALL PIPING MATERIAL IS IN ACCORDANCE WITH SAUDI ARAMCO ENGINEERING SPECIFICATION
2 SAES-L-105 CLASS 1LE0U . ALL EXCEPTIONS ARE NOTED ON THE ISOMETRIC.

REFER BELOW TABLE


FLG4 10X2"N.B. FIELD MATERIALS 11. INSULATION SHOWN ON DRAWING
12. REFER TO HYDROSTATIC TEST DIAGRAM FOR TEST LIMIT AND PRESSURE.
13. FOR SMALL BORE LINES (UPTO 1-1/2" ) DIMENSIONS, ROUTING & SUPPORTING SHALL BE FIELD ADJUSTED.
14. ALL DIMENSIONS AND COORDINATES ARE IN MM. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF THE SPOOL.

PT N.B. 15. FOR INTERNAL LINED PIPE, LINING SHALL BE DONE AFTER SPOOL FABRICATION & COMPLETION OF ALL HOT WORKS.

96 1 16. TIE-IN POINTS CO-ORDINATES TO BE VERIFIED BY CONTRACTOR IN FIELD.

NO DESCRIPTION (INS) STOCK CODE QTY 17. PAINTING / COATING SHALL BE IN ACCORDANCE WITH SAES-H-001/002 AND PROJECT APPROVED COATING MAP.
18. SEAL WELDING REQUIREMENT OF THREADED JOINTS SHALL BE AS PER CL.NO.9 OF SAES-L-110.
6
50 GASKETS
19. WELDS SHALL BE RADIOGRAPHED AS PER SAES-W-012 (FOR LINES WITH DESIGN CODE ASME B31.8/B31.4) &

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
AS PER SAES-W-011 (FOR LINES WITH DESIGN CODE ASME B31.3).
3 20. CONSTRUCTION OF PLANT PIPING SHALL BE IN ACCORDANCE WITH SAES-L-350.

6 GASKET , SYNTHETIC W/ CENTERING RING , 10 PGGNSC20115BL02 2 21. ALL INTERFACE CONNECTIONS WITH OTHER PROJECT (WHEREVER APPLICABLE), CO-ORDINATES AND ELEVATIONS
SHALL BE VERIFIED BY CONTRACTOR IN FIELD.
22. INTERNAL FBE LINING CONTRACTOR TO VERIFY AND CONFIRM THE BREAK UP FLANGES PRIOR TO THE SPOOL FABRICATION
FULL FACE , 1/16" (1.6 MM) THK , 23. PLANT COORDINATE SYSTEM HAS BEEN FOLLOWED AS PART OF BI-10-00930.

CL150 , B16.5 , B16.21 HIGH POINT OF PLANT DATUM ELEVATION 100.000m WHICH EQUALS 2.05m ABOVE MEAN SEA LEVEL

FLG4 GAS6 BLT8 7 GASKET , SYNTHETIC W/ CENTERING RING , 2 PGGNSC20115BL02 2 SPOOLS TO BE FABRICATED BY VENDOR
1 FULL FACE , 1/16" (1.6 MM) THK ,
NO. WEIGHT NO. WEIGHT

48
MARK NO. SIZE MARK NO. SIZE
PIECES LBS PIECES LBS

CL150 , B16.5 , B16.21

BOLTS
8 STUD BOLT (CONT) , CR-MO A193-B7 , W/ 2 7/8 PB1BLCSACS16002 24
SF HVY HEX NUTS , A194-2H , B1.1 ,
CERAMIC-FLUOROPOLYMER COATED , DIA
(IMP) X LEN (MET) - 115 mm Length
9 STUD BOLT (CONT) , CR-MO A193-B7 , W/ 2 5/8 PB1BLCSACS16002 8
2400
SF HVY HEX NUTS , A194-2H , B1.1 ,
CERAMIC-FLUOROPOLYMER COATED , DIA SPOOLS TO BE FABRICATED BY SAUDI ARAMCO
(IMP) X LEN (MET) - 80 mm Length NO.
PIECES
MARK NO. SIZE
NO.
PIECES
MARK NO. SIZE
1

VALVES / IN-LINE ITEMS


10 GATE VALVE , CS A216-WCB , CL150 , FF , 2 PVGC2S15FF8ABWV 1
B16.5 , B16.10 DIMS , API 600, OS&Y ,
BB , B61/B62 BRONZE TRIM (LESS THAN
16% ZINC) , INT FBE LND BODY , HW
11 BLIND FLG , CS A105N , CL150 , FF , 2 PFBC1B15FF0005V 1
1517

B16.5 , FBE INT COATED

PIECE MARKS
REFERENCE DRAWINGS
95 96
DRAWING CONTROL SHEET FOR J.O. 10-00930-0002 RD-086148
PIPING PLAN RA-685466.001
P&ID NA-518622.008
LINE DESIGNATION TABLE RD-912750
10"N.B.

HYDROSTATIC TEST DIAGRAM RA-901147-001


PROJECT PIPING MATERIAL SPECIFICATION RE-685500
1

PIPE SUPPORT STANDARD RE-901041

REVISION VALIDATION

THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

10-00930-0002-001
FLG4 10"N.B.
Worley 48
DESIGN CERTIFICATION

ENGG./DATE
(DESIGN AGENCY)
CERTIFIED BY/DATE
REVIEW FOR KEY DRAWINGS
REQUIRED
CONST. AGENCY/DATE
(SAUDI ARAMCO)
OPERATIONS/DATE BY/DATE
OTHER

FOR CONT. SEE 1 RAM WAB MKH AMM


SHT 029 04/07/23 04/07/23 04/07/23 04/07/23

E 30329871 07 May 2023 3 REV.NO. DATE REVISION DESCRIPTION

00 04/07/23 ISSUED FOR CONSTRUCTION


N 31000472
EL +100869 95 JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-00930-0002
ISSUED FOR CONSTRUCTION
CONSTRUCTION UNTIL CERTIFIED AND DATED

FLG4 GAS6 BLT8


FOR CONT. SEE
SAUDI ARABIAN OIL COMPANY
DRAWING TYPE

SHT 027 ISO 10"-OW-5063-1LE0U ISO


E 30331576 EQUALIZATION TANKS
N 30999990 CHEMICAL DESIGN OPERATING TEST PRESS. TEST RADIOGRAPHY % INSULATION TRACING PAINTING STRESS LINE ID
EL +99987 CLEANING TEMP. PRESS. TEMP. PRESS. (PSIG) MEDIUM SHOP FIELD THK. TYPE SYS NO. TERMINAL NORTH
(DEG. F) (PSIG) (DEG. F) (MM) SAUDI ARABIA
(PSIG) RAS TANURA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

NO 150 262 120 49 NOTE-12 WATER NOTE-19 NOTE-19 0 mm NO NOTE-17 SYS-02 OW-5063
060 L RB-901085 028 00
Saudi Aramco 2825 ENG. (05/05)

RESTRICTED
SA-TR-799 SMART CADD-03