OP Relay Kit Installation For Emerson
OP Relay Kit Installation For Emerson
OP Relay Kit Installation For Emerson
OP relay Kit
User Manual
Installation
The installation will apply to 10K(L)/20K(L) models
Step 1: Remove U cover by unscrewing all
screws.
Remove U cover
Step 2: For 10K(L) model,remove two wires on For 20k(L) model, remove a brown wire.
the PSDR board.
Brown wire
Step 3: For 10K(L) model, screw OP relay board For 20k(L) model, first lock a short brown wire to P1 point
to the location beneath the PSDR board. of OP relay board and then screw a short blue wire to P3
point of the board
Step 4: For 10K(L) model, connect O/P L point Short Brown wire
of PSDR board to P1 point of OP relay board with brown wire
a short brown wire supplied in the package.
Connect O/P N of PSDR board to P3 of OP relay
board with a short blue wire and connect the
blue wire which is removed in step 3 to P3 of the
OP relay board. Refer to the right chart. Connect
4-pin brown
the brown wire which is removed in step 3 to P2
Short blue wire Blue wire cable
of the OP relay board.
Connect CN1 of OP relay board to CN15 of PSDR
board with a 4-pin brown cable.
CN15 of PSDR
board
For 20k(L) model, connect the short brown wire Long brown wire
supplied in step 4 to I/P L point of OP EMI
board .Connect O/P L point of PSDR board to P1
point of OP relay board with a long brown wire
supplied in the package. Connect P3 point of OP
relay board to I/P N point of OP EMI board with
a short blue wire supplied in Step 4. Connect
4-pin brown
CN1 of OP relay board to CN15 of PSDR board
cable
with a 4-pin brown cable.