OP Relay Kit Installation For Emerson

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Accessory

OP relay Kit

User Manual
Installation
The installation will apply to 10K(L)/20K(L) models
Step 1: Remove U cover by unscrewing all
screws.

Remove U cover

Step 2: For 10K(L) model,remove two wires on For 20k(L) model, remove a brown wire.
the PSDR board.
Brown wire

Brown wire Blue wire

Step 3: For 10K(L) model, screw OP relay board For 20k(L) model, first lock a short brown wire to P1 point
to the location beneath the PSDR board. of OP relay board and then screw a short blue wire to P3
point of the board

Short brown wire

Short blue wire


Screw the OP relay board to the location left the
OP EMI board, need two M3 screws

Step 4: For 10K(L) model, connect O/P L point Short Brown wire
of PSDR board to P1 point of OP relay board with brown wire
a short brown wire supplied in the package.
Connect O/P N of PSDR board to P3 of OP relay
board with a short blue wire and connect the
blue wire which is removed in step 3 to P3 of the
OP relay board. Refer to the right chart. Connect
4-pin brown
the brown wire which is removed in step 3 to P2
Short blue wire Blue wire cable
of the OP relay board.
Connect CN1 of OP relay board to CN15 of PSDR
board with a 4-pin brown cable.

CN15 of PSDR
board

For 20k(L) model, connect the short brown wire Long brown wire
supplied in step 4 to I/P L point of OP EMI
board .Connect O/P L point of PSDR board to P1
point of OP relay board with a long brown wire
supplied in the package. Connect P3 point of OP
relay board to I/P N point of OP EMI board with
a short blue wire supplied in Step 4. Connect
4-pin brown
CN1 of OP relay board to CN15 of PSDR board
cable
with a 4-pin brown cable.