Net Safety Millennium II Basic Gas Detector

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Millennium II BASIC Specification Sheet

BCR-0036-00-024 October 13, 2011

Millennium II BASIC Gas Detector


LED Indication (No Display) Transmitter/Sensor Package
“SMART” Gas Detector Series
Net Safety’s Millennium II BASIC gas detector
package is a robust and reliable safety solution
delivering highly accurate monitoring and
protection. Compatible with our state-of-the-art
SMART sensor technology, it provides a flexible
detection platform that includes all the features
users in the field demand with complete ease-of-
use and operation.

 SMART Sensor Technology Works with All Sensor Full Sensor Diagnostics

Types (IR, CatBead, EC, NE-MOS)
 Non-intrusive Menu System, Simple Set-up
 -55°C to +85°C Temperature Range and Calibrations via External Magnet or
Optional HART Port Connection
Lowest Power Consumption on the Market

Field Selectable Gas Curves and Ranges

 Wide Voltage Range Allows For Greater Stability
and System Compatibility Long Range (+2000ft.) Sensor Separation

Streamline Controller Design Global Certifications


Designed for applications that require a local, full-featured The Millennium II BASIC is approved to FM, CSA, ATEX, ANSI,
transmitter interface but do not require a character display. INMETRO, and GOST-R safety, technical and performance
The Millennium II BASIC includes bright LED indicators for standards.
Power/Alarm/Fault conditions with an optional HART interface.
Analog, Relay, Modbus 485 RTU & HART
SMART Sensor Technology Enhanced communication protocals allows the Millennium II
The transmitter can be fitted with a wide range of toxic and/ BASIC to work seamlessly with external safety equipment.
or combustible gas sensors. SMART (Self Monitoring Analysis
and Reporting Technology) sensors are pre-calibrated and easily Field-proven Sensor Innovations
connect to the transmitter which recognizes a newly fitted Solid state Nano-Enhanced MOS sensors that have the
sensor, automatically uploading it’s specific configuration profile. fastest H2S response and do not “fall asleep”; poison-
resistant Catalytic Bead with SensorGuard technology, which
Digital Communications prolongs sensor life; Infrared sensor technology utilizing
Sensor and transmitter continuously communicate digitally, a dual beam design with no mirrors that may become
giving you the confidence of stable, accurate protectionwith contaminated (“fogged up”) or misaligned; and a full range of
market-leading response times. Electrochemical toxic gas sensors.
PMS - Uncoated

PMS - Coated

CMYK

GRE
Grey
Millennium II BASIC Specification Sheet
BCR-0036-00-024 October 13, 2011

Millennium II BASIC Transmitter


Specifications
“SMART” Gas Detector Series
Electrical
ORDERING INFORMATION
Power Consumption 1.1W @ 24 or 12 Vdc (average - varies by sensor type)
M2B-A Single Channel - Analog
Voltage Range 10.5 – 32.0 Vdc (HART: 18 – 32 Vdc)
M2B-R Single Channel - Relay
RFI Immunity 150 to 170 MHz and 450 to 470 MHz, 5W FM radio 1m away
M2B-D Single Channel - RS485 Modbus
EMI Immunity IEC 61000-1-4 and IEC 61000-4-3 Severity Level 2
M2B-AH Single Channel - Analog &HART
Display Multi-color LED Indication (Normal/Fault/Alarm)
Enclosures Available: Aluminum (-A) Stainless Steel (-S)
Environmental
Temperature -55°C to +85°C (-67°F to +185°F) Certified Operating Range Ordering Matrix Example:
M2B-A-S (Transmitter - Output - Enclosure Material)
Relative Humidity 0-99% RH non condensing
Enclosure
Metallurgy Aluminum or 316 SS
Conduit Opening 3/4” NPT (3X) SPECIAL FEATURES
• Non-intrusive one man calibration (magnetic switch)
Outputs Optional: Analog 4-20mA, Four 5 Amp Form C Relays,
• Field selectable toxic gas ranges
RS 485 Modbus® RTU, and HART®
• Field selectable combustible gas curves
Certifications CSA | ANSI | ATEX | INMETRO | GOST-R
• Sensor Enable / Disable option from menu
Class 1, Division 1 - Groups BCD; Class 1, Zone 1, IP67, NEMA Type 4X
0575 II 2 G, Ex/AEx/EEx/BR-Ex/1Ex d IIB+H2, T5
ACCESSORIES
Factory Mutual (FM) 6310, 6320 | CSA-C22.2 No 152
• HART Port Adaptor
ANSI/ISA 92.0.01, 92.03.01 | EN 61779-1 and -4
• Calibration Cup
Sensors Combustible Gases: Infrared, Catalytic Bead
• Mounting Bracket c/w Hardware
Toxic Gases: Electrochemical, NE-MOS
• Sun Shade/Deluge Protection
Warranty 3 years
• Duct Mount and Hardware Kit
Mounting Surface Mount / Pipe Mount / Duct Mount • Dust/Sand filter
Weight Aluminum: 0.8 kg (2.0 lbs), Stainless Steel (316SS): 1.6 kg (3.5 lbs)

A B C D E
Aluminum Housings 6.3 160 5.6 142 5.4 137 9.7 246 6.0 152
Stainless Steel Housings 5.9 150 5.1 130 4.6 117 8.9 226 6.0 152
F G H I
Aluminum Housings 5.7 145 2.6 66 2.9 74 4.1 103
Stainless Steel Housings 5.8 147 2.6 66 2.9 74 3.9 100

PMS - Uncoated

PMS - Coated

5.05” 5.72”
3/4” NPT
CMYK

4.65” 3.90”

GRE
Grey

8.95”
Millennium II BASIC Specification Sheet
BCR-0036-00-024 October 13, 2011

Millennium II Series Combustible Gas Sensors


Catalytic Bead and Infrared Specifications
“SMART” Gas Detector Series
COMBUSTIBLE GASES [%LEL] COMBUSTIBLE GASES [%LEL]
CATALYTIC BEAD INFRARED
P/N: SC310(A/S)-100-ASSY P/N: SC311(A/S)-100-ASSY

Performance
Response Time T50 ≤ 5.5sec T50 ≤ 4.3 sec
T60 ≤ 6sec T60 ≤ 7 sec
T90 ≤ 12sec T90 ≤ 11 sec
Accuracy (+/-) 3% < 50% | (+/-) 5% > 50% (+/-) 2% < 50% | (+/-) 5% > 50%
Detection Range 0 — 100% LEL 0 — 100% LEL
Primary Detectable Gases: Methane, Propane, n-Butane, Primary Detectable Gases: Methane, Propane, n-Butane,
Isobutylene, Hydrogen, Ethane, Pentane, Hexane, Heptane, Iso-Pentane, n-Pentane, Ethane, Iso-Butane, Ethylene, Hexane
Ethylene, Propylene, Methanol, Ethanol (Field Selectable Curves)

Zero Drift (+/-) 2% per month n/a


Repeatability (+/-) 1% LEL full scale (+/-) 2% LEL full scale
Environmental
Temperature Certified: -40°C to +75°C (-40°F to 167°F) | Performance Verified: -55°C to +85°C (-67°F to 185°F)
Relative Humidity 0–99% RH non condensing
Enclosure
Metallurgy Aluminum or 316 SS
Certifications Factory Mutual (FM) Class 6310, 6320 Factory Mutual (FM) Class 6310, 6320
CSA C22.2 No. 152 | ANSI/ISA 12.13.01 CSA C22.2 No. 152 | ANSI/ISA 12.13.01
IEC/EN 61779-1 and -4 IEC/EN 61779-1 and -4 | SIL2 by TÜV SÜD
CSA — Class 1, Division 1, Grps BCD; Class 1, Zone 1, Ex/AEx d IIB+H2
ATEX | INMETRO | GOST-R — 0575 II 2 G, Ex/BR-Ex/1Ex d IIB+H2
Temperature Rating: T5 | IP 66/67 (filter) | NEMA Type 4x
Sensor Separation Up to 2000 feet/600 meters (18 AWG cabling)
Warranty 5 years
Special Features • Patented SensorGuard Technology • Dual Beam Technology
• Poison Resistant • Sintered Metal IR Lamp Protection
• Custom K-factor Input (via HART) • “Quick” Calibration Option

PMS - Uncoated

PMS - Coated

CMYK

GRE
Grey
Millennium II BASIC Specification Sheet
BCR-0036-00-024
BCR-0033-00-028 October 13, 2011

Millennium II Series Toxic Gas Sensors


NE-MOS (Metal Oxide Semiconductor) Specifications
“SMART” Gas Detector Series
HYDROGEN SULPHIDE [H2S] AMMONIA [NH3]
(SOLID STATE NE-MOS) (SOLID STATE NE-MOS)
P/N: ST321(A/S)-100-ASSY P/N: ST371(A/S)-300-ASSY

Performance
Response Time T20 ≤ 7sec T20 ≤ 8 sec
T50 ≤ 13sec T50 ≤ 16 sec
T90 ≤ 17sec
Accuracy (+/–) 2ppm (+/–) 5ppm
Detection Range 0—20/50/100 ppm 0—50/100/300 ppm
(Field Selectable) (Field Selectable)
Zero Drift 2ppm over 6 months 2ppm over 6 months
Repeatability (+/–) 1ppm or 5% full scale (+/–) 2ppm or 5% full scale
Environmental
Temperature Certified: -40°C to +60°C (-40°F to 140°F) | Performance Verified: -40°C to +65°C (-67°F to 149°F)
Relative Humidity 0–95% RH non condensing 0–90% RH non condensing
Enclosure
Metallurgy Aluminum or 316 SS
Certifications ANSI/ISA-S 92.0.01 | SIL2 by TÜV SÜD ANSI/ISA-S 92.03.01
CSA — Class 1, Division 1, Grps BCD; Class 1, Zone 1, Ex/AEx d IIB+H2
ATEX | INMETRO | GOST-R — 0575 II 2 G, Ex/BR-Ex/1Ex d IIB+H2

Temperature Rating: T5 | IP 66/67 (filter) | NEMA Type 4x


Sensor Separation Up to 2000 feet/600 meters (18 AWG cabling)
Warranty 2 years 6 months
Special Features • Nano-Enhanced Sensor Technology - Response, Performance
• Enhanced Sensor Diagnostics

PMS - Uncoated

PMS - Coated

CMYK

GRE
Grey
Millennium II BASIC Specification Sheet
BCR-0036-00-024 October 13, 2011

Millennium II Series Toxic Gas Sensors


XChem Electrochemical Specifications
“SMART” Gas Detector Series
HYDROGEN SULPHIDE CARBON MONOXIDE [CO] SULPHUR DIOXIDE [SO2] OXYGEN [O2]
[H2S] (ELECTROCHEMICAL) (ELECTROCHEMICAL) (ELECTROCHEMICAL) (ELECTROCHEMICAL)
P/N: ST320(A/S)-100-ASSY P/N: ST360(A/S)-1000-ASSY P/N: ST330(A/S)-100-ASSY P/N: ST341(A/S)-25-ASSY

Performance
Response Time T20 ≤ 10 sec T20 ≤ 10 sec T20 ≤ 9 sec T20 ≤ 8 sec
T50 ≤ 15 sec T50 ≤ 15 sec T50 ≤ 15 sec T50 ≤ 10 sec
T90 ≤ 30 sec T90 ≤ 30 sec T90 ≤ 30 sec T90 ≤ 20 sec
Accuracy (+/–) 3% Full Scale
Detection Range 0­­—20/50/100 ppm 0­—500/1000 ppm 0­—20/100 ppm
0—25% Oxygen
(Field Selectable) (Field Selectable) (Field Selectable)
Zero Drift < 5% per year < 5% per year < 0.1 ppm per year < 5% per year
Repeatability < 3% full scale < 3% full scale < 2 ppm full scale < 3% full scale
Environmental
Temperature -40°C to +50°C -20°C to +50°C -30°C to +50°C -20°C to +50°C
(-40°F to 122°F) (-4°F to 122°F) (-22°F to 122°F) (-4°F to 122°F)
Relative Humidity 5–95% RH non condensing
Enclosure
Metallurgy Aluminum or 316 SS
Certifications CSA — Class 1, Div 1, Grps BCD; Class 1, Zone 1, Ex/AEx d IIB+H2
ATEX (pending) — 0575 II 2 G, Ex IIB+ H2
IECEx (pending) — Ex d IIB+H2 Gb
Temperature Rating: T5 | IP 66/67 (filter) | NEMA Type 4x | EMI/EMC 61326
Sensor Separation Up to 2000 feet/600 meters (18 AWG cabling)
Warranty 2 years
Special Features • Enhanced Sensor Diagnostics • Enhanced Sensor
• Field Selectable Ranges Diagnostics

PMS - Uncoated

PMS - Coated

CMYK

GRE
Grey
Millennium II BASIC Specification Sheet
BCR-0036-00-024 October 13, 2011

Millennium II Series Toxic Gas Sensors


XChem Electrochemical Specifications
“SMART” Gas Detector Series
NITRIC OXIDE [NO] NITROGEN DIOXIDE [NO2] CHLORINE [CI2]
(ELECTROCHEMICAL) (ELECTROCHEMICAL) (ELECTROCHEMICAL)
P/N: ST372(A/S)-100-ASSY P/N: ST373(A/S)-10-ASSY P/N: ST350(A/S)-10-ASSY

Performance
Response Time T20 ≤ 6 sec T20 ≤ 10 sec T20 ≤ 10 sec
T50 ≤ 9 sec T50 ≤ 20 sec T50 ≤ 21 sec
T90 ≤ 23 sec T90 ≤ 40 sec T90 ≤ 60 sec
Accuracy 3% Full Scale
Detection Range 0­–5/10 ppm
0­–100 ppm 0­–10 ppm
(Field Selectable)
Zero Drift < 0.3 ppm per year < 0.03 ppm per year < 0.03 ppm per year
Repeatability < 3% full scale < 0.2 ppm full scale < 0.2 ppm full scale
Environmental
Temperature -30°C to +50°C -20°C to +50°C -20°C to +50°C
(-22°F to 122°F) (-4°F to 122°F) (-4°F to 122°F)
Relative Humidity 5–95% RH non condensing
Enclosure
Metallurgy Aluminum or 316 SS
Certifications CSA — Class 1, Div 1, Grps BCD; Class 1, Zone 1, Ex/AEx d IIB+H2
ATEX (pending) — 0575 II 2 G, Ex IIB+ H2
IECEx (pending) — Ex d IIB+H2 Gb
Temperature Rating: T5 | IP 66/67 (filter) | NEMA Type 4x | EMI/EMC 61326
Sensor Separation Up to 2000 feet/600 meters (18 AWG cabling)
Warranty 2 years
Special Features • Enhanced Sensor Diagnostics
• Enhanced Sensor Diagnostics
• Field Selectable Ranges

PMS - Uncoated

PMS - Coated

CMYK

GRE
Grey
Millennium II BASIC Specification Sheet
BCR-0036-00-024 October 13, 2011

Millennium II Series
Separation Boxes & Accessories
“SMART” Gas Detector Series
SEPARATION BOXES
Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications)
JB-MPD-S Digital Output - Stainless Steel
JB-MPD-A Digital Output - Aluminum

ACCESSORIES
UDM-001 Universal duct mount assembly with 1M inlet sampling pipe - Stainless Steel
UDM-002 Universal duct mount assembly with 1.5M inlet sampling pipe - Stainless Steel
UDM-003 Universal duct mount assembly - Stainless Steel
UDM-EX1 1M extension - for use with UDM-001 & UDM-002 - Stainless Steel
UDM-EX2 1.5M extension - for use with UDM-001 & UDM-002 - Stainless Steel

CCS-1 Calibration Cup/Rain Shield/Splash Guard/Dust Filter with DF-1
DSC-1 Dust / Sand protective clip (includes DF-1 disposable filter)

IPF-001 IP 66/67 Filter for SX3 Series sensors, enhanced sensor protection from contamination by dirt and moisture

UN-MK-31 1” Pipe Mounting kit c/w stainless steel mounting bracket and hardware
UN-MK-32 2” Pipe Mounting kit c/w stainless steel mounting bracket and hardware
UN-MK-33 3” Pipe Mounting kit c/w stainless steel mounting bracket and hardware

HPT-001 HART Communicator port, mounts directly to JB-MPH-A/S or Millennium II transmitter


JB-MPH-A Separation box - Aluminum - used to remote mount HART port (HPT-001)
JB-MPH-S Separation box - Stainless steel - used to remote mount HART port (HPT-001)

SSK-51 1” Pipe Mounted Sun shade kit/rain guard - Stainless steel - Includes UN-MK-31 Mounting kit
SSK-52 2” Pipe Mounted Sun shade kit/rain guard - Stainless steel - includes UN-MK-32 Mounting kit
SSK-53 3” Pipe Mounted Sun shade kit/rain guard - Stainless steel - Includes UN-MK-33 Mounting kit

PMS - Uncoated

PMS - Coated

CMYK

GRE
Grey
Millennium II BASIC Specification Sheet
BCR-0036-00-024 October 13, 2011

HEADQUARTERS:
FLAME AND GAS DETECTION
Emerson Process Management
Net Safety Monitoring Inc.
2721 Hopewell Place NE
Calgary, Alberta, Canada T1Y 7J7
T +1 (403) 219 0688
T 1 866 FIREGAS
F +1 (403) 219 0694
www.net-safety.com

HEADQUARTERS: HEADQUARTERS: HEADQUARTERS:


GAS CHROMATOGRAPHS PROCESS ANALYTICAL LIQUID ANALYTICAL
Emerson Process Management Emerson Process Management Emerson Process Management
Rosemount Analytical Rosemount Analytical Rosemount Analytical
5650 Brittmoore Road 6565 P Davis Industrial Parkway 2400 Barranca Parkway
Houston, TX 77041 USA Solon, OH 44139 USA Irvine, CA 92606 USA
T +1 (713) 827 6380 T +1 (440) 914 1261 T +1 (949) 757 8500
T 1 866 422 3683 T 1 800 433 6076 T 1 800 854 8257
F +1 (713) 827 3865 F +1 (440) 914 1262 F +1 (949) 474 7250
www.raihome.com www.raihome.com www.raihome.com

©2011 Emerson Process Management. All rights reserved.


Emerson Process Management, Rosemount Analytical, Net Safety Monitoring, and PlantWeb are
marks of Emerson Process Management group of companies. All other marks are the property of
their respective owners.
The contents of this publication are presented for information purposes only, and while effort has
been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
PMS - Uncoated

express or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request. We reserve the
right to modify or improve the designs or specifications of our products at any time without notice.

PMS - Coated

CMYK

GRE
Grey

You might also like