Saginomiya produces electronic expansion valves for refrigeration and air conditioning applications. Their valves come in various types for different uses including UKV-S, LKV-S, and UKV valves for air conditioning as well as UKV, VKV, and AKV valves for refrigeration units. The document provides specifications for each valve type including applicable refrigerants, port sizes, applications, and nominal capacities.

Uploaded by

Mostafa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views4 pages

KV en

Saginomiya produces electronic expansion valves for refrigeration and air conditioning applications. Their valves come in various types for different uses including UKV-S, LKV-S, and UKV valves for air conditioning as well as UKV, VKV, and AKV valves for refrigeration units. The document provides specifications for each valve type including applicable refrigerants, port sizes, applications, and nominal capacities.

Uploaded by

Mostafa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ELECTRONIC EXPANSION

VALVE series
Products Digest Catalog

For Refrigeration and


Air conditioning…
SAGINOMIYA Electronic Expansion Valve series
for wide range of applications
and specifications Type UKV-S

Type UKV
(for Refrigeration unit)
Type AKV
Type PKV

Type LKV-S
Type VKV
ELECTRONIC EXPANSION VALVE
● Used in various applications and controls
Application Type Feature Refrigerant Nominal Capacity (U.S.R.T.)
High pressure differential,
UKV-S
Air Conditioning compact size

VKV Applicable for hot-gas line


・Room air conditioner
・Ducted residential air R410A
UKV-F With internal check valve function
conditioner
・Packaged air Low valve leakage
LKV-S
conditioner and Low flow noise type
・VRF
AKV Applicable for hot-gas line

UKV Wide range of port size


Refrigeration Unit
Applicable for low temperature
PKV R404A
(-50°C)
・Freezer
・Cold storage
Applicable for extreme low
・Display case GKV
temperature (-70°C) ※1  
R23

AKV Applicable for hot-gas line


・Chiller R134a
MKV Large capacity

・Household refrigerator 2-way, 3-way, 4-way


・Vending machine RKV R600a
changeover
Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C 0 10 20 30 40 70
For other refrigerants,please contact SAGINOMIYA.
※1: Based on condensing temp. -10˚C, evaporating temp. -50˚C, sub-cooling 0˚C and superheat 0˚C

Application Type Feature Refrigerant Nominal Capacity (U.S.R.T.)

CO2 Refrigerant UKV-J


※2
・Display case R744(CO2)
・Freezer JKV
Applicable for ultra-high
pressure (15MPa)
UKV-J
・Heat pump water ※3
heater R744(CO2)
JKV

※2: Based on condensing temp. -5˚C, evaporating temp. -25˚C, sub-cooling 0˚C and superheat 0˚C 0 10 20 30 40 70
※3: Based on gas cooler outlet temp. 22°C, gas cooler outlet pressure 9.5MPa, evaporating temp. 6°C and superheat 0°C

Air Conditioning

Type UKV-S OEM


High pressure differential, compact size

Refrigerant * R410A, R32, R134a, R22


Port Size (mm) 0.8 to 6.1
Application Packaged air conditioner, VRF (for Outdoor unit)
Nominal Capacity (100%open) R22    0.4 to 33.6 {1.5 to 118.4}
(U.S.R.T.){kW} R410A   0.5 to 39.5 {1.8 to 139.2}
Port Size φ0.8 to 4.0 Port Size φ4.0 to 6.1
※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C

Type LKV-S OEM


Low internal Leakage and flow noise type

Refrigerant * R410A, R32, R134a, R22


Port Size (mm) 1.3 to 3.2
Application Packaged air conditioner, VRF (for Indoor unit)
Nominal Capacity (100%open)
R410A 2.0 to 10.1 {6.9 to 35.6}
(U.S.R.T.){kW}
Port Size φ1.3 to 3.2 ※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C

*For other refrigerant the above, please contact SAGINOMIYA.


*Consent to "Important Notice for usage" is required when using with flammable refrigerants. Please contact us for details.
Type UKV-F OEM
With internal check valve function

Refrigerant * R410A, R32, R134a, R22


Port Size (mm) 1.9 to 3.2
Cv Value (A → B) 0.47
B
Application Residential air conditioner
※Based on condensing temp. 38˚C, evaporating temp. 5˚C,
Nominal Capacity (100%open) R22    2.9 to 6.4 {10.3 to 22.5} sub-cooling 0˚C and superheat 0˚C
(U.S.R.T.){kW} ※B→A: Flow control
R410A   3.4 to 7.5 {12.1 to 26.5} ※A→B: Flow bypass
A

Refrigeration Unit
Type UKV OEM
Wide range of port size

R448A, R449A, R407H, R134a,


Refrigerant * R404A, R407C, R463A-J, R410A,
R1234yf, R290, R600a
Port Size (mm) 1.8 to 4.0
Application Freezer, Cold storage, Display case
Nominal Capacity (100%open) R22   0.4 to 11.1 {1.5 to 39.1}
(U.S.R.T.){kW} R404A   1.1 to 27.6 {0.3 to 7.8}
※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C

Type VKV OEM


Type AKV
Applicable for hot-gas line Applicable for hot-gas line

R448A, R449A, R407H, R134a, R448A, R449A, R407H, R134a,


Refrigerant * R404A, R407C, R463A-J, R410A, Refrigerant * R404A, R407C, R463A-J, R410A,
R1234yf, R290 R1234yf, R290, R600a
Port Size (mm) 1.4 to 4.0 Port Size (mm) 5.5, 6.5
Application Freezer, Cold storage, Display case Application Chiller, VRF, etc.
Nominal Capacity (100%open) R22   1.5 to 13.2 {5.2 to 46.4} Nominal Capacity (100%open) R134a   18.5 / 22.0 {65.2 / 77.3}
(U.S.R.T.){kW} R410A  1.7 to 15.5 {6.1 to 54.5} (U.S.R.T.){kW} R410A  27.9 / 33.0 {98.1 / 116.2}
※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C ※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C
Please contact us for hot gas bypass application. Please contact us for hot gas bypass application.

Type MKV Type PKV


Large capacity Applicable for low temperature (-50°C)

R448A, R449A, R407H, R134a,


Refrigerant *
Refrigerant * R134a, R404A, R407C, R22 R404A, R407C, R463A-J, R410A
Port Size (mm) 16.0 Port Size (mm) 1.4 to 3.0
Application Chiller, etc. Application Freezer, Cold storage, Display case
Nominal Capacity (100%open) R22    82.5 {290.5} Nominal Capacity (100%open) R22   1.5 to 7.9 {5.2 to 27.8}
(U.S.R.T.){kW} R134a  64.5 {227.1} (U.S.R.T.){kW} R404A  1.0 to 5.6 {3.6 to 19.6}
※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C ※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C

*For other refrigerant the above, please contact SAGINOMIYA.


*Consent to "Important Notice for usage" is required when using with flammable refrigerants. Please contact us for details.
Type GKV Type RKV
Applicable for extreme low OEM
temperature (-70°C) 2-way, 3-way, 4-way
changeover

2-way change 3-way change 4-way change


R23, R448A, R449A, R407H, R134a, over valve over valve over valve
Refrigerant *
R404A, R407C, R463A-J, R410A
Refrigerant * R600a, R290, R1234yf, R134a
Port Size (mm) 1.8 to 6.0
Port Size (mm) 0.8, 1.0
Application Freezer, Cold storage, Display case
※1 Application Refrigerator, Vending machine
Nominal Capacity (100%open) R23   3.5 to 18.9 {12.4 to 66.7}
(U.S.R.T.){kW} ※2 Nominal Capacity (100%open) R600a 0.40 / 0.48 {1.4 / 1.7}
R404A  2.1 to 11.1 {7.3 to 39.2}
(U.S.R.T.){kW} R134a 0.45 / 0.54 {1.6 / 1.9}
※1: Based on condensing temp. -10˚C, evaporating temp. -50˚C, sub-cooling 0˚C and superheat 0˚C
※2: Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C ※Based on condensing temp. 38˚C, evaporating temp. 5˚C, sub-cooling 0˚C and superheat 0˚C

CO2 Refrigerant NEW

Type UKV-J OEM


Type JKV
Applicable for ultra-high pressure OEM
(15MPa) Applicable for ultra-high
pressure (15MPa)
JKV-20D JKV-24D JKV-40D
* *
Refrigerant R744 (CO2) Refrigerant R744 (CO2)
Port Size (mm) 0.8 to 1.4 Port Size (mm) 2.0 to 4.0
Application Heat pump water heaters, Display case Application Heat pump water heaters, Display case
Nominal Capacity (100%open) R744 0.8 to 2.9 {2.8 to 10.2} ※1 Nominal Capacity (100%open) R744 6.2 to 31.4 {21.9 to 110.4} ※1
(U.S.R.T.){kW}  1.1 to 3.9 {3.7 to 13.6} ※2 (U.S.R.T.){kW}  8.2 to 41.5 {29.0 to 146.3} ※2
※1: Based on condensing temp. -5˚C, evaporating temp. -25˚C, sub-cooling 0˚C and superheat 0˚C ※1: Based on condensing temp. -5˚C, evaporating temp. -25˚C, sub-cooling 0˚C and superheat 0˚C
※2: Based on gas cooler outlet temp. 22°C, gas cooler outlet pressure 9.5MPa, evaporating temp. ※2: Based on gas cooler outlet temp. 22°C, gas cooler outlet pressure 9.5MPa, evaporating temp.
6°C and superheat 0°C 6°C and superheat 0°C

*For other refrigerant the above, please contact SAGINOMIYA.


*Consent to "Important Notice for usage" is required when using with flammable refrigerants. Please contact us for details.
SYSTEM EXAMPLE

Outdoor expansion valve Outdoor unit


Condenser
Indoor expansion valve
① ④ 4-way reversing
valve
Sub-cooling

Injection ③
⑤ Compressor

Hot gas bypass


Accumulator
※Please contact us for hot gas bypass application.

Indoor unit ②
Evaporator

Cooling cycle
Evaporator
Heating cycle

<Asia> 2022.1
Saginomiya (Thailand) Co., Ltd. E-mail : [email protected]
Tel : +66-2260-8364 Fax : +66-2260-8366
<Europe, Middle East, Africa>
SAGINOMIYA EUROPE Sp. z o.o. E-mail : [email protected]
<Japan, Korea, Oceania> Tel : +48-22-101-30-00 Fax : +48-22-101-30-01
E-mail : [email protected] <North America, Latin America>
Tel : +81-3-6205-9120 Fax : +81-3-6205-9122 SAGINOMIYA AMERICA, INC. E-mail : [email protected]
URL : http://www.saginomiya-global.com/en/ Tel : +1-614-766-7390 Fax : +1-614-766-7391