BOQ - Blank
BOQ - Blank
BOQ
ITEM ITEM DESCRIPTION UNIT QTY
RATE AMOUNT
ACTIVE INFRASTRUCTURE
Fifth Floor - UTP
1 Layer 2, 10/100/1000 BASE-T, 24 ports rack mountable type POE nos 3 -
+370W switch CISCO/ARUBA
2 Manageble, 10/100/1000 BASE-T, 24 ports rack mountable type nos 2 -
nonPOE switch including 4x1G SFP MM (layer3 some featured
supported) CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
Fifth Floor - Fiber
3 Manageble, 10/100/1000 BASE-T, 24 ports rack mountable type nos 3 -
nonPOE switch including 4x1G SFP MM (layer3 some featured
supported) CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
Fouth Floor
ACTIVE INFRASTRUCTURE
4 Layer 2, 10/100/1000 BASE-T, 24 ports rack mountable type POE nos 1 -
+370W switch CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
Third Floor
ACTIVE INFRASTRUCTURE
5 Layer 2, 10/100/1000 BASE-T, 24 ports rack mountable type POE nos 1 -
+370W switch CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
Second Floor
ACTIVE INFRASTRUCTURE
6 Layer 2, 10/100/1000 BASE-T, 24 ports rack mountable type POE nos 1 -
+370W switch CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
First Floor
ACTIVE INFRASTRUCTURE
7 Layer 2, 10/100/1000 BASE-T, 24 ports rack mountable type POE nos 1 -
+370W switch CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
Ground Floor
ACTIVE INFRASTRUCTURE
8 Layer 2, 10/100/1000 BASE-T, 24 ports rack mountable type POE nos 1 -
+370W switch CISCO/ARUBA
Note - Non Stackable switch all uplinks considered as UTP Copper ports
9 Testing and commisioning of the active network system and hand over the nos 1 -
system documantation including operational training(1day training)
Total - Excluding VAT and any other taxes at the time of invoicing -
Scope - PASSIVE INFRASTRUCTURE
BOQ
ITEM ITEM DESCRIPTION UNIT QTY
RATE AMOUNT
PASSIVE INFRASTRUCTURE
Fifth Floor - UTP
1 19"- 12RU Wall mounting rack including necessary patch panel, nos 2 -
patch Cables, cable Management,ventilation facilities to
accommodate all necessary accessories for Data system PUBUDU,
TIMIK or A&G
Fouth Floor
PASSIVE INFRASTRUCTURE
8 19"- 9RU Wall mounting rack including necessary, patch panel, nos 1 -
patch Cables, cable Managements,ventilation facilities to
accommodate all necessary accessories for Data system TIMIK or
A&G
9 Data nos 10 -
10 UTP Uplinks Rack to Rack nos 2 -
Third Floor
PASSIVE INFRASTRUCTURE
11 19"- 9RU Wall mounting rack including necessary patch panel, nos 1 -
patch Cablescable Managements,ventilation facilities to
accommodate all necessary accessories for Data system TIMIK or
A&G
12 Data nos 10 -
13 UTP Uplinks Rack to Rack nos 2 -
Second Floor
PASSIVE INFRASTRUCTURE
14 19"- 9RU Wall mounting rack including necessary patch panel, nos 1 -
patch Cables, cable Managements,ventilation facilities to
accommodate all necessary accessories for Data system TIMIK or
A&G
15 Data nos 10 -
16 UTP Uplinks Rack to Rack nos 2 -
First Floor
PASSIVE INFRASTRUCTURE
17 19"- 9RU Wall mounting rack including necessary patch panel, nos 1 -
patch Cables, cable Managements,ventilation facilities to
accommodate all necessary accessories for Data system TIMIK or
A&G
20 Data nos 10 -
21 UTP Uplinks Rack to Rack nos 2 -
23,534.00 47,068.00
560.00 112,000.00
1,376.00 11,008.00
344.00 5,504.00
113.75 101,692.50
270.94 121,110.18
75.00 20,625.00
2.25 2,250.00
4.00 4,000.00
1,450.00 2,900.00
175,580.00 252,577.68