2-Storey Residential BLDG
2-Storey Residential BLDG
2-Storey Residential BLDG
CE 134 Project
University of the Philippines Los Baños
Design Criteria
A. Design Code
National Structural Code of the Philippines, 2010
American Concrete Institute
B. Material Strengths
Concrete: fc’ = 28 MPa
Reinforcing Steel (Beam and Column) Fy = 414 MPa (>12mmØ bars)
Reinforcing Steel (Slab): Fy = 275 MPa (10mm &12mmØ bars)
Allowable Soil Bearing Capacity Q = 100 kPa
C. Design Loads
Dead Loads:
Normal-weight Concrete (γconc) : 23.544 kN/m3
Interior Wall Loads : 0.05 kPa
Utilities : 0.50 kPa
Topping and Finishes : 1.10 kPa
Partition Loads : 1.00 kPa
Live Loads:
Residential (Basic Floor Area) : 1.90 kPa
Residential (Exterior Balcony) : 2.90 kPa
SLAB DESIGN
The following parameters were considered in order to compute for the design of the 2nd
floor and attic slabs:
SLAB SCHEDULE
REINFORCEMENT
REMARKS
SHORT SPAN LONG SPAN
Thk (mm)
Top Bars @ Top Bars @ Top Bars @ Top Bars @ Top Bars @ Top Bars @
Disc. Edge Disc. Edge Disc. Edge Disc. Edge Disc. Edge Disc. Edge
12 mm @ 12 mm @ 12 mm @ 12 mm @ 12 mm @ 12 mm @
2S-1 100 TWO WAY
200 mm o.c. 200 mm o.c. 200 mm o.c. 200 mm o.c. 200 mm o.c. 200 mm o.c.
12 mm @ 12 mm @ 12 mm @ 10 mm @ 10 mm @ 10 mm @
2S-2 100 ONE WAY
275 mm o.c. 275 mm o.c. 275 mm o.c. 425 mm o.c. 425 mm o.c. 425 mm o.c.
12 mm @ 12 mm @ 12 mm @ 12 mm @ 12 mm @ 12 mm @
AS-1 100 TWO WAY
200 mm o.c. 200 mm o.c. 200 mm o.c. 200 mm o.c. 200 mm o.c. 200 mm o.c.
12 mm @ 12 mm @ 12 mm @ 10 mm @ 10 mm @ 10 mm @
AS-2 100 ONE WAY
275 mm o.c. 275 mm o.c. 275 mm o.c. 425 mm o.c. 425 mm o.c. 425 mm o.c.
COLUMN DESIGN
The following parameters were considered in order to compute for the adequacy of the
G/F and 2/F columns:
COLUMN SCHEDULE
GROUND TO 2ND FLOOR (C1) 2ND FLOOR TO ATTIC (C1)
Size: 300 mm x 300 mm Size: 300 mm x 300 mm
The following parameters were considered in order to compute for the design of the 2/F and
Atticbeams:
BEAM SCHEDULE
Dimension REINFORCEMENT
LEFT RIGHT Web Stirrup
MARK bxh MIDSPAN
SUPPORT SUPPORT bars Schedule
TOP BOT TOP BOT TOP BOT
If s < s max , use s. Otherwise, use s max. If s < s max , use s. Otherwise, use s max.
Design of Columns
Column-A
Ties 256
Øties = 10 mm LTS= 480 250 mm
300