The document outlines the area requirements for a museum, including galleries, administration areas, workshops, and more. It provides the number of users, required area in square meters, quantity needed, and overall area for each space type. The total built up area required is outlined as 7,200 square meters, with 30% of that allotted for transition spaces. Parking requirements and toilet specifications are also included.

Uploaded by

Jeffrey John
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views9 pages

Review 2 Sheeets Progress

The document outlines the area requirements for a museum, including galleries, administration areas, workshops, and more. It provides the number of users, required area in square meters, quantity needed, and overall area for each space type. The total built up area required is outlined as 7,200 square meters, with 30% of that allotted for transition spaces. Parking requirements and toilet specifications are also included.

Uploaded by

Jeffrey John
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

AREA REQUIREMENTS

Footfall – 900 to 1000/day


Sl. Spaces No.of users Area in Quantity Overall Area
no. sqm In sqm
1. ENTRANCE
Lobby 100 1 100
Reception with Information 2 15 1 15
desk
back office +storage 3 20 1 20
Ticket counter 2 10 1 10
Cloak room 1 15 1 15
Total 160 sqm

2. ADMINISTRATION
(Total no.of staffs -52)
Directors office 1 15 1 15

Deputy Superintending 1 15 1 15
archaeologist Engineer
Asst.Superintending 1 10 1 10
archaeologist Engineer
Staff room 10 30 3 90
(30) (2sqm/person)
Meeting room 10pax 15 1 15
Security monitoring room 1 10 1 10
Server room 1 10 1 10
Maintenance room 1 12 1 12
Canteen
(1.4sqm/person)
Seating area 30 60 1 60
1.4sqm/person
Kitchen 40 1 40
storage 20 1 20
Wash basin 4
W.C 1.2 3 3.6
(M-1/F-2)
Research centre
Stratigraphy department
Lab 50 2 100
studio 30 2 60
Computer lab 30 1 30
Staff room 5 15 1 15
(2sqm/person)

Total 526 sqm

3. CURATORIAL DEPARTMENT
Curator specialist Officer 1 15 1 15
Stone gallery curator 1 10 1 10
Pottery gallery curator 1 10 1 10
Copper gallery curator 1 10 1 10
Animal objects curator 1 10 1 10
Jewellery gallery curator 1 10 1 10
Store room(files) 1 20 2 40
Store room(conservationlabs) 1 100 1 100
Store room(preservation lab) 1 100 1 100
Store room(Artifacts) medium 3 150 1 200
Store room(Artifacts) Large 3 200 1 200
Crating room 2 50 1 50
Total 755 sqm

4. GALLERIES
Security cabin 1 5 1 5
Temporary exhibition gallery 150 1 150
Stones gallery 200 2 400
Pottery antiques gallery 200 2 400
Metal gallery 200 2 400
Animal object gallery 100 1 100
Weaving culture gallery 100 1 100
Jewellery gallery 200 2 400
Copper gallery 200 1 200
VR room 200 1 200
270 deg room 100 1 100
Total 2455 sqm

5. WORKSHOPS
Archaeological mapping 10 persons
workshop
studio 20 1 20
store room 15 1 15
Artificial excavation pit 100 1 100
workspace 30 1 30
Classification and 8-10 persons
preservation
workshop
studio 30 2 60
storage 20 2 40
Preservation studio 100 2 200
Total 465 sqm

6. LIBRARY
Reading hall 150 1 150
Librarian’s cabin 10 1 10
Cloak room 6 1 6
Total 166 sqm

7 SEMINAR HALL 300 pax 250 1 250


(0.8sqm/per)
8 CAFETARIA 200 1 200
(1.4sqm/person)

Seating area 100 150 1 150


1.4sqm/person
Kitchen 80 1 80
storage 20 2 20
Wash basin 8
W.C 1.2 6 7.2
(M-2/F-3)

9 Museum shop 100 1 100

10. LABORATORY
wet lab 25 2 50
Dry lab 20 2 40
Preservation labs 100 3 300
Total 390 sqm

11. SERVICES
Maintanence room 20 1 20
Janitor room 10 1 10
AHU room 25 1 25
Other services 100 1 100
Total 155 sqm

BUILT UP AREA 6000sqm(approx)


Transition space 30% of total 1200 sqm
Built up
Total built up area 7200 sqm

13. PARKING
1 car space and two wheeler
for
50 sqm(TNCDBR)

Other spaces

10%of total site area for OSR


Maximum FSI allowed -2.0
Distance between two fire
exits not exceedind more
than 18m

14. TOILETS (VISITORS) M F


W.C 5 7
W.B 4 5
Urinals 9 -

TOILETS (staff) M F
W.C 2 3
W.B 3 4
Urinals 3 -