Weber WVS 250
Weber WVS 250
Weber WVS 250
WVS 250
STANDARD SPECIFICATIONS
1.
Volvo
ENGINEfour stroke heavy duty high performance industrial type
diesel engine
3. COOLING RADIATOR
200 kW 219 kW Radiator and cooling fan, complete with safety guards,de-
signed to cool the engine at high ambient temperatures(con-
480 V,3 ph,60 Hz,1800 rpm 257 kVA 279 kVA sult your dealer for deration factors)
4. EXHAUST SYSTEM
203 kW 224 kW Heavy duty Industrial Exhaust Silencer
6. FUEL SYSTEM
On Generating sets upto 700kVA, the baseframe
design is incorporated with an integral fuel tank with a capacity
of approx. 8 hours running at full load. The tank is supplied
complete with fill cap breather, fuel speed and return lines to
the engine and drain plug.
7. ALTERNATOR
7.1 INSULATION SYSTEM
• Insulation : Class H
Engine Make Volvo Penta • All windings are impregnated in either a triple dip
thermosetting liquid,oil and acid resisting polyester varnish or
Engine Model TAD734GE vaccum pressure impregnated with a special polyester resin.
• Heavy coat of antitracking varnish additional protection
against moisture or condenasation.
Governing Type Electronic
7.2 AUTOMATIC VOLTAGE REGULATOR (AVR)
Number of Cylinders 6 The fully sealed AVR maintains the voltage regulation at ±0.5%.
Nominal adjustment by means of a trim pot incorporated on
the AVR.
Cylinder Arrangement Vertical In Line
7.3 MOTOR STARTING
An overload capacity equivalent to 300% of the full load
Bore and Stroke mm 108x130 impedance at zero power factor can be sustained for 10
sec.,when AREP or PMG option is fitted.
Displacement / Cubic Capacity ltrs 7.15
8. MOUNTING ARRANGEMENT
8.1 BASE FRAME
Aspiration Turbocharged The complete generating set is mounted as a whole on a heavy
duty fabricated steel baseframe.
Cycle 4 stroke
8.2 COUPLING
The engine and alternator are directly coupled by means of an
Combustion System Direct Injection SAE flange.The engine flywheel is flexibly coupled to the
alternator rotor.
Compression Ratio 17:1 8.3 ANTI-VIBRATION MOUNTING PADS
Anti-vibration pads are affixed between the engine / alternator
feet and the baseframe thus ensuring complete vibration
isolation of the rotating assembly.
Powered by :
Frequency and Engine Speed 50Hz & 1500rpm 60Hz & 1800rpm
Prime Prime
9. FACTORY TESTS
▪ The generating set is load tested before dispatch.
▪ All protective devices control functions and site load
Make Leroy Somer TAL / Stamford conditions are simulated.The generator and it's systems are
checked before dispatch.
Model TAL 046D / UCDI274K 10. EQUIPMENT FINISHING
All mild steel components are fully degreased and painted with
No. of bearings 1 powder coated paint to ensure maximum scuff resistance and
durability.