Communication Protocol Between Monitoring Platform and BMS
Communication Protocol Between Monitoring Platform and BMS
Version information
1 summary ................................................................................................................................................ 3
2 Reference standard
The communication uses TCP transmission in 2G GPRS, GAT1 in 4G,
socket interface mode,
rs232ttl serial port, content custom communication format, and baud rate of
115200.
3 Network topology
This protocol is a point-to-point or bus mode between BMS, GPS, Bluetooth,
PC and terminal.
4 Protocol content
10 Checksum 4
BMS Response
2 LENGTH 2
3 Terminal number 4
4 Command word 1
6 Transport type 1 0.Read data, 1.Answer frame 2.Data box active upload
10 Checksum 4
Example: GPS Writing Data Reference
10 Checksum 4
BMS Response
2 LENGTH 2
3 Terminal number 4
4 Command word 1
10 Checksum 4
Sign Code Note: (Background Data Identification Code 0x00 when reading all
data)
5.1 BMS Set Data Identification Code
R 0x80 Reader tube 2 HEX Over 100 percent of the 0 -- 140 (- 40 to 100
temperature degrees C) temperature is negative, such as
101 being negative 1 degrees (100
benchmarks)
R 0x81 Read the 2 HEX 0-140 (- 40 to 100 ℃), the part exceeding 100
temperature in is the negative temperature, as above (100
the battery box reference)
R 0x82 Read battery 2 HEX 0-140 (- 40 to 100 ℃), the part exceeding 100
temperature is the negative temperature, as above (100
reference)
R 0 X 87 Number of 2 HEX
battery cycles
R 0 X 89 Total battery 4 HEX Ah
cycle capacity
RW High 2 HEX
0 xa 4 0 - 100 ℃
Temperature
Protection Value
for Battery
Discharge
RW Charging 2 HEX
0 xa 5
cryoprotection - 45 ℃ /+ 25 ℃(No datum - signed data)
value
RW 0 xae Protective Board 1 HEX This site is reserved and used in cascade,
Address
System working 4
RW 0xb6 time HEX Reset when leaving the factory, unit: Min
RW Actual battery 4 AH
0xb9 capacity HEX
[Note]
1. In all fields of 0x79 ~ 0xb9, R or RW marked should be reported, for the old
version that has been shipped, upgrade as far as possible;If upgrade is not convenient,
please contact our technical support at 13755639263/13480924112
2. 0xBA manufacturer ID name, this field is mainly used for switching cabinets, if
there is a need for switching cabinets, this field must be added.