K2 English Manual
K2 English Manual
Digital Keypad
Introduction
The K02 uses the latest microprocessor technology to operate door strikes and
security systems that require a momentary (timed) or latching dry contact closure.
All programming is done through the keypad. Codes and operating parameters are
stored within the microprocessor and can not be lost due to power failure.
The K02 can store 1000 prox cards and user 4 digit codes. Each 4 digit code has
10,000 possible combinations. The unit has one relay with 5 Amp contacts.
CONTENTS Page
Introduction ……………………………………………………………. 2
Product Specifications …………………………………………………. 3
Intramural Interface Circuit…………………………………………….
Mounting & PCB Diagram ……………………………………………. 4
Wiring Diagram ………………………………………………………. 4-5
Engineer Programming Information and Notes …………………….. 5
Engineer Programming
Factory Default Setting ………………………………………….. 6
Changing Master & User Codes………………………………….. 7
Setting Functions of Master & User ……………………………. 7
Set Door Relay Strike ……………………………………………… 7
Set Door Open Detection Time …………………………………. 8
Security Arrangement ……………………………………………. 9
Exit Engineer Programming Mode ……………………………… 9
Resetting Non Volatile Memory ………………………………………. 9
Installer Information & Notes …………………………………………… 9
Technical Specifications ….…………………………………………… 10
2
Specifications
1. Programmable Functions
Relay latching or momentary
Relay activate independently or together
Change Codes 1 master, 1000 users & prox cards
Door open detection
2. Programmable Timers
Door relay time 00-99 seconds
Door open detection 00-99 seconds
Alarm time 00-99 minutes
3. Wiring Connections
Electric lock
External bell
External Push Switch
Magnetic Contacts
Alarm
4. Keypad:
12 keys
5. Programming memory:
Non volatile Eeprom memory
IMPORTANT INFORAMTION
There are no user serviceable parts contained within the K2 access control keypad.
If holes are to be drilled before mounting onto a wall, check for hidden cables and/or
pipes before drilling. Use safety goggles when drilling or hammering in cable clips.
Every effort has been made to provide accurate information, however slight variations
can occur. We also reserve the right to make changes for product improvement at
any time
NOTE
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL THE K2
3
Intramural Interface Circuit
1. Alarm output interface (See Figure 1)
2. Electric lock interface (See Figure 2)
Figure 1 Figure 2
Mounting
1. Attach the rear plate to a single or double gang electrical box or secure to the
wall firmly with at least three flat head screws.
2. When wiring has been completed, attach the front cover to the rear plate.
Figure 3
Figure 4
The front cover can be permanently secured by using the short screw supplied
K2 Printed Circuit Board
4
Wiring
1. Unplug the cable harness and connect the necessary cables, (See Figure 5).
2. Tape any wires that are unused.
3. Plug the cable harness , (See Figure 5)
4. Attach the front cover, (See Figure 3).
DO NOT PLUG ADAPTOR OUR TRANSFORMER INTO MAINS UNTIL ALL WIRING HAS
BEEN COMPLETED AND THE FRONT COVER SECURED.
Figure 5
5
Power Up
1. After all wiring is complete and the unit face plate is attached to the back plate,
apply 12Vdc power to the unit. Accept LED(the yellow LED) flashing.
Note
Press: # to save changes and exit engineer programming, when all programming
has been completed otherwise changes will not be saved.
6
User Operation Mode
There are 3 different options for user operation mode, card only, card and password,
valid code. The optioned used is common to all users.
The door relay output can be operated as either normally opened or normally closed,
a maximum current of 10 ampere can pass through the relay if used as normally
opened or 5 ampere if normally closed. The door relay time can be set from 0
seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and
can be changed through the keypad.
In order for this feature to work, door contacts must be connected. There are 2
programming functions that work together in this mode.
There are two levels of keypad security available for the K2.
7
Resetting To Factory Default Setting
To revert all settings to the factory default values then the Non Volatile Memory
(Eeprom) must be reset.
Reset Non Volatile Memory by switching of the power and placing the jumper
connector onto the pins 1 & 2 as per figure 2. After switching power on remove
jumper, the K2 will give a beep and is now reset to factory default values.
The factory default setting for each user password code 1234, this can be modified so
that each user has a unique individual 4 digit code.
Technical Specification
DC Supply Voltage: Low voltage input 12 ±10% Vdc unregulated
Current Consumption: 100mA @ quiescent maximum
Door Relay: 5Amp 12Vdc
Alarm output load: 150mA pull current
Tamper Protection: Negative loop, normally closed
Codes : 1 Master, 1000 cards and 1000 codes .
Keypad: 12 keys, 3 LED status indicators
Card Types: EM or EM compatible
Induction Distance: 5-8cm
Wiring Connections: Electric lock
Remote door control
Door open detection
External door bell
External Alarm
8