0% found this document useful (0 votes)
231 views55 pages

Detail

This document is a title sheet for a building project located at 10655 N.E. 4th Street, Suite 606 in Bellevue, WA. It provides information on the architect, Ricardo J. Muniz-Guillet, AIA, located in Cumming, GA. It also lists the current issue date of November 30th, 2022 and that this issue is "Issued for Permit". Several sheets are then indexed including sheets for architecture, lighting, and general information.

Uploaded by

Joen Gabalunos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
231 views55 pages

Detail

This document is a title sheet for a building project located at 10655 N.E. 4th Street, Suite 606 in Bellevue, WA. It provides information on the architect, Ricardo J. Muniz-Guillet, AIA, located in Cumming, GA. It also lists the current issue date of November 30th, 2022 and that this issue is "Issued for Permit". Several sheets are then indexed including sheets for architecture, lighting, and general information.

Uploaded by

Joen Gabalunos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 55

2901 Clint Moore Rd, #114

Boca Raton, FL 33496


888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

11/30/2022 8:26:01 PM
OWNER:

10655 N.E. 4th Street, Suite 606 |


Bellevue, WA 98004

[email protected]
P:(425) 598-8516
PROJECT INFORMATION:

MEDFORD, OR

Prototype Version 3.0


August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.

1 A1 2022.11.30 ISSUED FOR


PERMIT

CURRENT ISSUE:

ISSUE FOR PERMIT

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:

PJ/RG
CHECKED BY:

LA/RB
PROJECT #:

B4-250-2101
SHEET NAME:

TITLE SHEET
H2S-MEDFORD,OR
HILTON PROJECT #: 21- 506ND SHEET NUMBER:

PROTOTYPE VERSION: Prototype Version 3.0


August 2022 G-000
0" 1"
SHEET INDEX LIGHTING SHEET INDEX ARCHITECTURE SHEET INDEX GENERAL
SHEET CURRENT CURRENT ISSUE A-808 CONST. DETAILS @ CEILINGS 2022.11.30 ISSUED FOR PERMIT SHEET CURRENT CURRENT ISSUE
SHEET NAME A-809 CONST. DETAILS @ COLUMNS 2022.11.30 ISSUED FOR PERMIT
NUMBER ISSUE DATE DESCRIPTION NUMBER SHEET NAME ISSUE DATE DESCRIPTION
A-811 CONST. DETAILS @ VESTIBULE 2022.11.30 ISSUED FOR PERMIT
LT-001 GENERAL NOTES, LEGENDS AND ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT G-000 TITLE SHEET 2022.11.30 ISSUED FOR PERMIT
A-812 CONST. DETAILS @ EXT. FINISHES "A" 2022.11.30 ISSUED FOR PERMIT
LT-002A LIGHTING FIXTURE SCHEDULE-1 2022.11.30 ISSUED FOR PERMIT G-001 SHEET INDEX 2022.11.30 ISSUED FOR PERMIT
A-813A CONSTRUCTION DETAILS @ EIFS 2022.11.30 ISSUED FOR PERMIT
LT-002B LIGHTING FIXTURE SCHEDULE-2 2022.11.30 ISSUED FOR PERMIT G-002 PROJECT INFORMATION AND GENERAL NOTES 2022.11.30 ISSUED FOR PERMIT
A-813B CONSTRUCTION DETAILS @ EIFS 2022.11.30 ISSUED FOR PERMIT 2901 Clint Moore Rd, #114
LT-003 LIGHTING CONTROL SCHEDULE 2022.11.30 ISSUED FOR PERMIT G-003 CODE SUMMARY 2022.11.30 ISSUED FOR PERMIT
A-813C CONSTRUCTION DETAILS @ EIFS 2022.11.30 ISSUED FOR PERMIT Boca Raton, FL 33496
LT-101 LIGHTING DETAILS-1 2022.11.30 ISSUED FOR PERMIT G-004 ABBREVIATIONS, SYMBOLS, AND LEGENDS 2022.11.30 ISSUED FOR PERMIT
LT-102 LIGHTING DETAILS-2 2022.11.30 ISSUED FOR PERMIT
A-813D CONSTRUCTION DETAILS @ EIFS 2022.11.30 ISSUED FOR PERMIT
G-010 ADA 2009 ACCESSIBILITY DETAILS 2022.11.30 ISSUED FOR PERMIT
888.901.8008 www.base-4.com
A-900 MILLWORK DRAWINGS- BREAKFAST SERVING COUNTER 2022.11.30 ISSUED FOR PERMIT
LT-200A SITE LIGHTING PLAN 2022.11.30 ISSUED FOR PERMIT G-011 ADA 2009 ACCESSIBILITY DETAILS 2022.11.30 ISSUED FOR PERMIT ARCHITECT:
A-901 MILLWORK DRAWINGS-MEDIA WALL,COFFEEBAR & BUSINESS STATION 2022.11.30 ISSUED FOR PERMIT
LT-200B SITE PHOTOMETRICS PLAN 2022.11.30 ISSUED FOR PERMIT G-012 ADA 2009 ACCESSIBILITY DETAILS 2022.11.30 ISSUED FOR PERMIT
A-902 MILLWORK DRAWINGS- HOME2 MARKET & RECEPTION HALL 2022.11.30 ISSUED FOR PERMIT Ricardo J. Muniz-Guillet, AIA
LT-201 1ST FLOOR LIGHTING PLAN 2022.11.30 ISSUED FOR PERMIT G-013 ADA 2009 ACCESSIBILITY DETAILS 2022.11.30 ISSUED FOR PERMIT
A-903 MILLWORK DRAWINGS- FRONT DESK 2022.11.30 ISSUED FOR PERMIT 2030 Habersham Trce
LT-202 2ND FLOOR LIGHTING PLAN 2022.11.30 ISSUED FOR PERMIT G-014 ADA 2009 ACCESSIBILITY DETAILS 2022.11.30 ISSUED FOR PERMIT
A-904 MILLWORK DRAWINGS- GUEST LAUNDRY 2022.11.30 ISSUED FOR PERMIT
LT-203 3RD FLOOR LIGHTING PLAN 2022.11.30 ISSUED FOR PERMIT G-020 STANDARD MOUNTING DETAILS (2015) 2022.11.30 ISSUED FOR PERMIT Cumming, GA 30041
A-905 MILLWORK DRAWINGS- WINDOW PERCH 2022.11.30 ISSUED FOR PERMIT
LT-204 4TH FLOOR LIGHTING PLAN 2022.11.30 ISSUED FOR PERMIT
Grand total: 118
954.812.6650
LT-205 ROOF LIGHTING PLAN 2022.11.30 ISSUED FOR PERMIT [email protected]
LT-206 EXTERIOR ELEVATIONS-1 2022.11.30 ISSUED FOR PERMIT SHEET INDEX ARCHITECTURE
LT-207 EXTERIOR ELEVATIONS-2 2022.11.30 ISSUED FOR PERMIT
A-000 ARCHITECTURAL SITE PLAN 2022.11.30 ISSUED FOR PERMIT
LT-208 TYPICAL UNIT LIGHTING PLAN-1 2022.11.30 ISSUED FOR PERMIT
LT-209 TYPICAL UNIT LIGHTING PLAN-2 2022.11.30 ISSUED FOR PERMIT SHEET INDEX STRUCTURE A-001
A-010
DUMPSTER / SITE DETAILS
1ST FLOOR LIFE SAFETY AND OCCUPANCY PLAN
2022.11.30
2022.11.30
ISSUED FOR PERMIT
ISSUED FOR PERMIT
LT-210 DIMMER RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT SHEET CURRENT CURRENT ISSUE A-011 UPPER FLOOR LIFE SAFETY AND OCCUPANCY PLAN 2022.11.30 ISSUED FOR PERMIT
SHEET NAME
NUMBER ISSUE DATE DESCRIPTION A-012 LIFE SAFETY DETAILS 2022.11.30 ISSUED FOR PERMIT
SHEET INDEX PLUMBING S-101 INDEX AND ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT A-020A PARTITION TYPES 2022.11.30 ISSUED FOR PERMIT
S-102 STRUCTURAL NOTES (CONT.) 2022.11.30 ISSUED FOR PERMIT A-020B PARTITION TYPES 2022.11.30 ISSUED FOR PERMIT
SHEET CURRENT CURRENT ISSUE A-021 FLOOR AND ROOF TYPES 2022.11.30 ISSUED FOR PERMIT
SHEET NAME S-103 STRUCTURAL NOTES 2022.11.30 ISSUED FOR PERMIT
NUMBER ISSUE DATE DESCRIPTION S-104 SPECIAL INSPECTION NOTES (CONT.) 2022.11.30 ISSUED FOR PERMIT A-030 FIRE RATED DETAILS-1 2022.11.30 ISSUED FOR PERMIT
P-001 GENERAL NOTES, LEGEND & ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT S-105 SPECIAL INSPECTION NOTES 2022.11.30 ISSUED FOR PERMIT A-031 FIRE RATED DETAILS-2 2022.11.30 ISSUED FOR PERMIT
P-002 PEX GENERAL NOTES(A) 2022.11.30 ISSUED FOR PERMIT S-107 SCHEDULES 2022.11.30 ISSUED FOR PERMIT A-032 FIRE RATED DETAILS-3 2022.11.30 ISSUED FOR PERMIT
P-003 PEX GENERAL NOTES(B) 2022.11.30 ISSUED FOR PERMIT S-108 SCHEDULES 2022.11.30 ISSUED FOR PERMIT A-033 FIRE RATED DETAILS-4 2022.11.30 ISSUED FOR PERMIT
P-101 DETAILS-1 2022.11.30 ISSUED FOR PERMIT S-109 SCHEDULES 2022.11.30 ISSUED FOR PERMIT A-034 FIRE RATED DETAILS-5 2022.11.30 ISSUED FOR PERMIT
P-102 DETAILS-2 2022.11.30 ISSUED FOR PERMIT S-110 SCHEDULES 2022.11.30 ISSUED FOR PERMIT A-035 FIRE RATED DETAILS-6 2022.11.30 ISSUED FOR PERMIT
P-103 DETAILS-3 2022.11.30 ISSUED FOR PERMIT S-111 GRAPHICAL COLUMN SCHEDULE 2022.11.30 ISSUED FOR PERMIT A-036 FIRE RATED DETAILS-7 2022.11.30 ISSUED FOR PERMIT 11/30/2022
2022-12-018:26:01 PM
20:37:46
P-201 1ST FLOOR WATER & GAS SUPPLY PLAN 2022.11.30 ISSUED FOR PERMIT S-200 FOUNDATION PLAN 2022.11.30 ISSUED FOR PERMIT A-037 FIRE RATED DETAILS-8 2022.11.30 ISSUED FOR PERMIT OWNER:
P-202 1ST FLOOR SANITARY & VENT PLAN 2022.11.30 ISSUED FOR PERMIT S-210 1ST FLOOR WALL AND COLUMN PLAN 2022.11.30 ISSUED FOR PERMIT A-038 FIRE PENETRATION DETAILS - WOOD 2022.11.30 ISSUED FOR PERMIT
P-203 2ND FLOOR WATER & GAS SUPPLY PLAN 2022.11.30 ISSUED FOR PERMIT S-220 2ND FLOOR STEEL FRAMING PLAN 2022.11.30 ISSUED FOR PERMIT A-039 FIRE PENETRATION DETAILS - WOOD 2022.11.30 ISSUED FOR PERMIT
P-204 2ND FLOOR SANITARY & VENT PLAN 2022.11.30 ISSUED FOR PERMIT S-221 2ND FLOOR FRAMING PLAN 2022.11.30 ISSUED FOR PERMIT A-040 FIRE PENETRATION DETAILS - WOOD 2022.11.30 ISSUED FOR PERMIT
P-205 3RD FLOOR WATER & GAS SUPPLY PLAN 2022.11.30 ISSUED FOR PERMIT S-222 2ND FLOOR WALL AND COLUMN PLAN 2022.11.30 ISSUED FOR PERMIT A-041 FIRE PENETRATION DETAILS - WOOD 2022.11.30 ISSUED FOR PERMIT
P-206 3RD FLOOR SANITARY & VENT PLAN 2022.11.30 ISSUED FOR PERMIT S-230 3RD FLOOR FRAMING PLAN 2022.11.30 ISSUED FOR PERMIT A-042 FIRE PENETRATION DETAILS - WOOD 2022.11.30 ISSUED FOR PERMIT
P-207 4TH FLOOR WATER & GAS SUPPLY PLAN 2022.11.30 ISSUED FOR PERMIT S-231 3RD FLOOR WALL AND COLUMN PLAN 2022.11.30 ISSUED FOR PERMIT A-100 1ST FLOOR PLAN 2022.11.30 ISSUED FOR PERMIT
P-208 4TH FLOOR SANITARY & VENT PLAN 2022.11.30 ISSUED FOR PERMIT S-240 4TH FLOOR FRAMING PLAN 2022.11.30 ISSUED FOR PERMIT A-101 2ND FLOOR PLAN 2022.11.30 ISSUED FOR PERMIT
P-209 ROOF PLUMBING PLAN 2022.11.30 ISSUED FOR PERMIT S-241 4TH FLOOR WALL AND COLUMN PLAN 2022.11.30 ISSUED FOR PERMIT A-102 3RD FLOOR PLAN 2022.11.30 ISSUED FOR PERMIT 10655 N.E. 4th Street, Suite 606 |
P-301A UNIT WATER SUPPLY PLAN-A 2022.11.30 ISSUED FOR PERMIT A-103 4TH FLOOR PLAN 2022.11.30 ISSUED FOR PERMIT
S-250 ROOF FRAMING PLAN 2022.11.30 ISSUED FOR PERMIT Bellevue, WA 98004
P-301B UNIT WATER SUPPLY PLAN-B 2022.11.30 ISSUED FOR PERMIT S-251 ROOF PARAPET PLAN 2022.11.30 ISSUED FOR PERMIT A-105 ROOF PLAN 2022.11.30 ISSUED FOR PERMIT
P-302A UNIT SANITARY & VENT PLAN-A 2022.11.30 ISSUED FOR PERMIT S-252 ROOF COMPONENT AND CLADDING PLAN 2022.11.30 ISSUED FOR PERMIT A-110 1ST FLOOR RCP 2022.11.30 ISSUED FOR PERMIT
P-302B UNIT SANITARY & VENT PLAN-B 2022.11.30 ISSUED FOR PERMIT A-111 2ND FLOOR RCP 2022.11.30 ISSUED FOR PERMIT [email protected]
S-301 WINDOW & DOOR WIND PRESSURES (CONT.) 2022.11.30 ISSUED FOR PERMIT
P-303A UNIT WATER SUPPLY RISER DIAGRAM-A 2022.11.30 ISSUED FOR PERMIT S-302 WINDOW & DOOR WIND PRESSURES 2022.11.30 ISSUED FOR PERMIT A-112 3RD FLOOR RCP 2022.11.30 ISSUED FOR PERMIT P:(425) 598-8516
P-303B UNIT WATER SUPPLY RISER DIAGRAM-B 2022.11.30 ISSUED FOR PERMIT S-401 BUILDING SECTIONS 2022.11.30 ISSUED FOR PERMIT A-113 4TH FLOOR RCP 2022.11.30 ISSUED FOR PERMIT PROJECT INFORMATION:
P-304A UNIT SANITARY & VENT RISER DIAGRAM-A 2022.11.30 ISSUED FOR PERMIT S-402 BUILDING SECTIONS 2022.11.30 ISSUED FOR PERMIT A-200 INTERIOR FINISH LEGENDS & NOTES 2022.11.30 ISSUED FOR PERMIT
P-304B UNIT SANITARY & VENT RISER DIAGRAM-B 2022.11.30 ISSUED FOR PERMIT S-501 WALL SECTIONS 2022.11.30 ISSUED FOR PERMIT A-201 ROOM FINISH SCHEDULE 2022.11.30 ISSUED FOR PERMIT
P-305 WATER SUPPLY RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT S-502 BEACON AND DUMPSTER DETAIL 2022.11.30 ISSUED FOR PERMIT A-300A ENLARGED PORTE COCHERE 2022.11.30 ISSUED FOR PERMIT
P-306 SANITARY & VENT RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT S-503 BIKE STAND AND CANOPY DETAIL 2022.11.30 ISSUED FOR PERMIT A-300B ENLARGED CANOPY 2022.11.30 ISSUED FOR PERMIT
P-307 STORM WATER RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT S-601 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-301A ENLARGED POOL PLAN 2022.11.30 ISSUED FOR PERMIT
P-308 GAS SUPPLY RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT S-602 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-301B ENLARGED POOL PLAN 2022.11.30 ISSUED FOR PERMIT
P-401 SCHEDULES 2022.11.30 ISSUED FOR PERMIT S-603 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-301C ENLARGED POOL ELEVATIONS & DETAILS 2022.11.30 ISSUED FOR PERMIT
S-604 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-301D ENLARGED POOL RESTROOM PLANS 2022.11.30 ISSUED FOR PERMIT
S-605 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-302A ENLARGED PATIO PLANS 2022.11.30 ISSUED FOR PERMIT MEDFORD, OR
SHEET INDEX FIRE ALARM S-606 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-302B
A-302C
ENLARGED PATIO PLANS
ENLARGED PATIO ELEVATIONS
2022.11.30
2022.11.30
ISSUED FOR PERMIT
ISSUED FOR PERMIT
S-607 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT
SHEET CURRENT CURRENT ISSUE S-608 TYPICAL DETAILS 2022.11.30 ISSUED FOR PERMIT A-303A ENLARGED LOBBY CONSTRUCTION PLAN 2022.11.30 ISSUED FOR PERMIT
SHEET NAME Prototype Version 3.0
NUMBER ISSUE DATE DESCRIPTION A-303B ENLARGED LOBBY REFLECTED CEILING PLAN 2022.11.30 ISSUED FOR PERMIT
FA-001 GENERAL NOTES, LEGENDS AND ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT A-303C ENLARGED LOBBY FURNITURE AND POWER PLAN 2022.11.30 ISSUED FOR PERMIT August 2022
FA-101 FIRE ALARM DETAIL-1 2022.11.30 ISSUED FOR PERMIT A-303D ENLARGED LOBBY FINISH FLOOR PLAN 2022.11.30 ISSUED FOR PERMIT
FA-102 FIRE ALARM DETAIL-2 2022.11.30 ISSUED FOR PERMIT SHEET INDEX MECHANICAL A-303E ENLARGED LOBBY ELEVATIONS & DETAILS 2022.11.30 ISSUED FOR PERMIT
ISSUE
NO.
DELTA ISSUE DATE DESCRIPTION
FA-201 1ST FLOOR FIRE ALARM PLAN 2022.11.30 ISSUED FOR PERMIT A-304A ENLARGED LAUNDRY PLANS 2022.11.30 ISSUED FOR PERMIT
SHEET CURRENT CURRENT ISSUE
FA-202 2ND FLOOR FIRE ALARM PLAN 2022.11.30 ISSUED FOR PERMIT SHEET NAME A-304B ENLARGED LAUNDRY PLANS 2022.11.30 ISSUED FOR PERMIT
1 A1 2022.11.30 ISSUED FOR
NUMBER ISSUE DATE DESCRIPTION A-305A ENLARGED FOOD PREP 2022.11.30 ISSUED FOR PERMIT
FA-203 3RD FLOOR FIRE ALARM PLAN 2022.11.30 ISSUED FOR PERMIT PERMIT
M-001 GENERAL NOTES, LEGEND & ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT A-305B ENLARGED FOOD PREP 2022.11.30 ISSUED FOR PERMIT
FA-204 4TH FLOOR FIRE ALARM PLAN 2022.11.30 ISSUED FOR PERMIT
M-101 DETAILS-1 2022.11.30 ISSUED FOR PERMIT A-306A ENLARGED FITNESS ROOM PLANS 2022.11.30 ISSUED FOR PERMIT
FA-205 ROOF FIRE ALARM PLAN 2022.11.30 ISSUED FOR PERMIT
M-102 DETAILS-2 2022.11.30 ISSUED FOR PERMIT A-306B ENLARGED FITNESS ROOM ELEVATIONS 2022.11.30 ISSUED FOR PERMIT
FA-301 TYPICAL FIRE ALARM RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT
M-201 1ST FLOOR MECHANICAL PLAN 2022.11.30 ISSUED FOR PERMIT A-307 ENLARGED BOH PLANS 2022.11.30 ISSUED FOR PERMIT
M-202 2ND FLOOR MECHANICAL PLAN 2022.11.30 ISSUED FOR PERMIT A-308A ENLARGED ADMINISTRATION AREAS 2022.11.30 ISSUED FOR PERMIT
M-203 3RD FLOOR MECHANICAL PLAN 2022.11.30 ISSUED FOR PERMIT A-308B ENLARGED ADMINISTRATION AREAS 2022.11.30 ISSUED FOR PERMIT
SHEET INDEX FIRE PROTECTION M-204 4TH FLOOR MECHANICAL PLAN 2022.11.30 ISSUED FOR PERMIT A-309 ENLARGE PUBLIC RESTROOM PLANS & ELEVATIONS 2022.11.30 ISSUED FOR PERMIT
M-205 ROOF MECHANICAL PLAN 2022.11.30 ISSUED FOR PERMIT A-310A ENLARGE 1ST FLOOR ELEVATOR LOBBY 2022.11.30 ISSUED FOR PERMIT
FP-001 GENERAL NOTES, LEGEND & ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT
M-301 SCHEDULE-1 2022.11.30 ISSUED FOR PERMIT A-310B ENLARGE 1ST FLOOR ELEVATOR LOBBY 2022.11.30 ISSUED FOR PERMIT
FP-101 1ST FLOOR FIRE SPECIFICATION PLAN 2022.11.30 ISSUED FOR PERMIT
M-302 SCHEDULE-2 2022.11.30 ISSUED FOR PERMIT A-311A ENLARGE TYPICAL ELEVATOR LOBBY 2022.11.30 ISSUED FOR PERMIT
FP-102 2ND FLOOR FIRE SPECIFICATION PLAN 2022.11.30 ISSUED FOR PERMIT
M-401 OA VENTILATION AND AIR BALANCE SCHEDULE 2022.11.30 ISSUED FOR PERMIT A-311B ENLARGE TYPICAL ELEVATOR LOBBY 2022.11.30 ISSUED FOR PERMIT
FP-103 3RD FLOOR FIRE SPECIFICATION PLAN 2022.11.30 ISSUED FOR PERMIT
M-501 PIPING RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT A-312A ENLARGE FIRST FLOOR CORRIDOR 2022.11.30 ISSUED FOR PERMIT
FP-104 4TH FLOOR FIRE SPECIFICATION PLAN 2022.11.30 ISSUED FOR PERMIT
A-312B ENLARGE FIRST FLOOR CORRIDOR 2022.11.30 ISSUED FOR PERMIT
A-313A ENLARGE TYPICAL FLOOR CORRIDOR 2022.11.30 ISSUED FOR PERMIT
SHEET INDEX ELECTRICAL A-313B
A-320
ENLARGE TYPICAL FLOOR CORRIDOR
STAIRCASE 1 PLANS & SECTIONS
2022.11.30
2022.11.30
ISSUED FOR PERMIT
ISSUED FOR PERMIT
SHEET CURRENT CURRENT ISSUE A-321 STAIRCASE 2 PLANS & SECTIONS 2022.11.30 ISSUED FOR PERMIT
SHEET NAME
NUMBER ISSUE DATE DESCRIPTION A-322 STAIRCASE DETAILS 2022.11.30 ISSUED FOR PERMIT
E-001 GENERAL NOTES, LEGENDS AND ABBREVIATIONS 2022.11.30 ISSUED FOR PERMIT A-330 ELEVATOR PLANS & SECTIONS 2022.11.30 ISSUED FOR PERMIT
E-101 ELECTRICAL DETAILS-1 2022.11.30 ISSUED FOR PERMIT A-331 ELEVATOR DETAILS 2022.11.30 ISSUED FOR PERMIT
E-102 ELECTRICAL DETAILS-2 2022.11.30 ISSUED FOR PERMIT A-340 LINEN CHUTE PLANS & SECTIONS 2022.11.30 ISSUED FOR PERMIT
E-103 ELECTRICAL DETAILS-3 2022.11.30 ISSUED FOR PERMIT A-400 GUESTROOM - ACC. KING SUITE CONN.(TUB) 2022.11.30 ISSUED FOR PERMIT
E-104 ELECTRICAL DETAILS-4 2022.11.30 ISSUED FOR PERMIT A-401 GUESTROOM - ACC. KING ONE BEDROOM(TUB) 2022.11.30 ISSUED FOR PERMIT
E-105 POOL GROUNDING DETAILS 2022.11.30 ISSUED FOR PERMIT A-402 GUESTROOM -DOUBLE QUEEN STUDIO ACC. CONN.(RIS) 2022.11.30 ISSUED FOR PERMIT
E-106 ELECTRICAL GROUNDING RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT A-403 GUESTROOM - KING ONE BEDROOM 2022.11.30 ISSUED FOR PERMIT CURRENT ISSUE:
E-200 SITE POWER PLAN 2022.11.30 ISSUED FOR PERMIT A-404 GUESTROOM - KING STUDIO 2022.11.30 ISSUED FOR PERMIT
E-201 1ST FLOOR POWER PLAN 2022.11.30 ISSUED FOR PERMIT A-405 GUESTROOM - KING STUDIO CONN. 2022.11.30 ISSUED FOR PERMIT
E-202 2ND FLOOR POWER PLAN 2022.11.30 ISSUED FOR PERMIT A-406 GUESTROOM - DOUBLE QUEEN STUDIO 2022.11.30 ISSUED FOR PERMIT ISSUE FOR PERMIT
E-203 3RD FLOOR POWER PLAN 2022.11.30 ISSUED FOR PERMIT A-407 GUESTROOM -DOUBLE QUEEN STUDIO CONN. 2022.11.30 ISSUED FOR PERMIT
E-204 4TH FLOOR POWER PLAN 2022.11.30 ISSUED FOR PERMIT A-408 GUESTROOM DETAILS 2022.11.30 ISSUED FOR PERMIT
E-205 ROOF POWER PLAN 2022.11.30 ISSUED FOR PERMIT A-450 RESTROOM - ACC. TUB AND RIS 2022.11.30 ISSUED FOR PERMIT CURRENT ISSUE DATE:
E-206 ENLARGED FLOOR POWER PLAN-1 2022.11.30 ISSUED FOR PERMIT A-451 RESTROOM - ACC. ONE BEDROOM TUB 2022.11.30 ISSUED FOR PERMIT
E-207 ENLARGED FLOOR POWER PLAN-2 2022.11.30 ISSUED FOR PERMIT A-452 RESTROOM - ACC. ONE BEDROOM RIS 2022.11.30 ISSUED FOR PERMIT 2022.11.30
E-208 TYPICAL UNIT ELECTRICAL PLAN-1 2022.11.30 ISSUED FOR PERMIT A-453 RESTROOM - SHOWER 2022.11.30 ISSUED FOR PERMIT DRAWN BY:
E-209 TYPICAL UNIT ELECTRICAL PLAN-2 2022.11.30 ISSUED FOR PERMIT A-500 DOOR SCHEDULE 2022.11.30 ISSUED FOR PERMIT
A-501 DOOR DETAILS 2022.11.30 ISSUED FOR PERMIT PJ/RG
E-301 PANEL SCHEDULE-I 2022.11.30 ISSUED FOR PERMIT
A-502 WINDOW SCHEDULE 2022.11.30 ISSUED FOR PERMIT CHECKED BY:
E-302 PANEL SCHEDULE-II 2022.11.30 ISSUED FOR PERMIT
A-503 STOREFRONT SCHEDULE 2022.11.30 ISSUED FOR PERMIT
E-303 PANEL SCHEDULE-III 2022.11.30 ISSUED FOR PERMIT LA/RB
E-304 PANEL SCHEDULE-IV 2022.11.30 ISSUED FOR PERMIT A-600 EXTERIOR ELEVATION & BUILDING SECTION 2022.11.30 ISSUED FOR PERMIT
A-601 EXTERIOR ELEVATION & BUILDING SECTION 2022.11.30 ISSUED FOR PERMIT PROJECT #:
E-305 PANEL SCHEDULE-V 2022.11.30 ISSUED FOR PERMIT
E-306 PANEL SCHEDULE-VI 2022.11.30 ISSUED FOR PERMIT A-602 EXTERIOR ELEVATION & BUILDING SECTION 2022.11.30 ISSUED FOR PERMIT B4-250-2101
E-307 PANEL SCHEDULE-VII 2022.11.30 ISSUED FOR PERMIT A-603 EXTERIOR ELEVATION & BUILDING SECTION 2022.11.30 ISSUED FOR PERMIT
SHEET NAME:
E-308 PANEL SCHEDULE VIII 2022.11.30 ISSUED FOR PERMIT A-604 BUILDING SECTIONS 2022.11.30 ISSUED FOR PERMIT
E-309 ELECTRICAL RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT A-700 WALL SECTIONS 2022.11.30 ISSUED FOR PERMIT
E-310 TELEPHONE, DATA AND TV RISER DIAGRAM 2022.11.30 ISSUED FOR PERMIT A-701 WALL SECTIONS 2022.11.30 ISSUED FOR PERMIT
A-800.A CONST. DETAILS @ ROOF 2022.11.30 ISSUED FOR PERMIT
FINAL SET RESPONSIBILITY A-800.B CONST. DETAILS @ ROOF 2022.11.30 ISSUED FOR PERMIT
A-800.C
A-801.A
CONST. DETAILS @ ROOF
CONST. DETAILS @ EXT. WALLS
2022.11.30
2022.11.30
ISSUED FOR PERMIT
ISSUED FOR PERMIT
SHEET INDEX
BASE4 WILL NOT BE RESPONSIBLE FOR CHANGES OF ANY
KIND (CHANGE ORDERS, BACK CHARGES, OR DELAY A-801.B CONST. DETAILS @ EXT. WALLS & BEAM WRAPPING 2022.11.30 ISSUED FOR PERMIT
CLAIMS) FROM ANY SET PROVIDED BY BASE4 BEFORE A-804 CONST. DETAILS @ WINDOWS 2022.11.30 ISSUED FOR PERMIT
THE RECEIPT OF A BUILDING PERMIT FROM THE AHJ. THIS A-805 CONST. DETAILS @ STOREFRONTS 2022.11.30 ISSUED FOR PERMIT
INCLUDES BUT IS NOT LIMITED TO PROGRESS SETS,
A-806 CONST. DETAILS @SHAFTS 2022.11.30 ISSUED FOR PERMIT
EARLY-STAGE RELEASES, FRANCHISE SUBMITTALS, OR SHEET NUMBER:
BID SETS. ONLY AHJ APPROVED PERMIT SETS SHALL BE A-807.A CONST. DETAILS @ INT. WALLS 2022.11.30 ISSUED FOR PERMIT

G-001
CONSIDERED ACCEPTABLE FOR CONSTRUCTION OR A-807.B CONST. DETAILS @ INT. WALLS 2022.11.30 ISSUED FOR PERMIT
FINAL PRICING. BIDDING, FABRICATING, OR BUILDING
FROM NON-PERMIT APPROVED DRAWINGS IS SOLELY AT
THE CONTRACTOR'S RISK.

0" 1"
GENERAL NOTES
GENERAL
1. THE INFORMATION HEREIN IS OF A PROPRIETARY NATURE AND IS SUBMITTED IN CONFIDENCE FOR USE BY BASE4 ARCHITECTS, INC. CLIENTS ONLY. IT HAS BEEN
PREPARED FOR THIS PROJECT AT THIS SITE AND IS NOT TO BE USED FOR ANY OTHER PURPOSE, LOCATION OR OWNER WITHOUT WRITTEN CONSENT OF BASE4
ARCHITECTS, INC. UNAUTHORIZED REPRODUCTION, PUBLICATION OR DISSEMINATION, IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED. INFORMATION CONTAINED
HEREIN REMAINS PROPERTY OF BASE4 ARCHITECTS, INC., AND RECEIPT OR POSSESSION OF THIS INFORMATION CONFERS NO RIGHT IN OR LICENSE TO USE OR
DISCLOSE TO OTHERS THE SUBJECT MATTER CONTAINED HEREIN FOR ANY BUT AUTHORIZED PURPOSES. ALL RIGHTS RESERVED.
2. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT BETWEEN OWNER AND CONTRACTOR, CONDITIONS OF THE CONTRACT (GENERAL, SUPPLEMENTARY, AND
OTHER CONDITIONS), DRAWINGS, SPECIFICATIONS, ADDENDA ISSUED PRIOR TO AGREEMENT AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT.
3. ANY DOCUMENT IN THIS SET WHICH HAS BEEN PREPARED BY ANY SUBCONTRACTOR, DESIGNER, AND/OR SUB-CONSULTANT WHO IS UNDER A CONTRACT DIRECTLY WITH 2901 Clint Moore Rd, #114
THE OWNER AND/OR CONTRACTOR IS ONLY INCLUDED IN THIS SET FOR PURPOSES OF REFERENCE AND COORDINATION. BASE4 ARCHITECTS DISCLAIMS ALL LIABILITY Boca Raton, FL 33496
RELATING TO THE DRAWING AND CONSTRUCTION OF THE IMPROVEMENTS OR SYSTEMS IT DEPICTS EXCEPT AS SPECIFICALLY ASSUMED IN A WRITTEN CONTRACT
SIGNED BY BASE4 AND THE OWNER. 888.901.8008 www.base-4.com
4. THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS, INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BY THE ARCHITECT, AND THE ARCHITECT'S
CONSULTANTS ARE INSTRUMENTS OF SERVICE THROUGH WHICH THE WORK TO BE EXECUTED BY THE CONTRACTOR IS DESCRIBED. UNLESS INDICATED OTHERWISE, ARCHITECT:
THE ARCHITECT AND ARCHITECT'S CONSULTANTS\ SHALL BE DEEMED THE AUTHORS OF THEM AND WILL RETAIN ALL COMMON \ LAW, STATUTORY AND OTHER RESERVED
RIGHTS, IN ADDITION TO THE COPYRIGHTS. Ricardo J. Muniz-Guillet, AIA
5. IF COORDINATION OF ARCHITECTURAL, CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SPRINKLER ELEMENTS RESULT IN
CONFLICT, GC SHALL NOTIFY ARCHITECT IN WRITING IMMEDIATELY PRIOR TO COMMENCING ANY WORK OF ELEMENTS RESULTING CONFLICTS 2030 Habersham Trce
6. SLOPE ALL GRADES AT PLANTING AREAS, SIDEWALKS AND ASPHALT PARKING PAVING WITHIN 5' OF A BUILDING AWAY FROM THE BUILDING. IF CONFLICTS OCCUR, Cumming, GA 30041
NOTIFY ARCHITECT IMMEDIATELY. SEE CIVIL DRAWINGS FOR FINISHED GRADES ADJACENT TO BUILDINGS.
7. CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS AND SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF CONSTRUCTION UNTIL FINAL 954.812.6650
LATERAL AND VERTICAL CARRYING SYSTEMS ARE COMPLETED. [email protected]
8. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF SUBCONTRACTOR WORK, COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS,
AND ACCURATE LOCATION OF STRUCTURAL MEMBERS, OPENINGS FOR MECHANICAL, ELECTRICAL, AND MISCELLANEOUS EQUIPMENT. CONTRACTOR SHALL VERIFY
DIMENSIONS AND OPENING SIZES (CLEARANCES REQUIRED) FROM THE MANUFACTURERS PRIOR TO CONSTRUCTION OF OR INSTALLATION OF EQUIPMENT, FURNISHINGS,
AND ACCESSORIES.
9. PROVIDE ACCESS PANELS AS REQUIRED. PROVIDE RATED ACCESS PANELS WITH THE SAME RATING AS THE ASSEMBLY IN WHICH THEY ARE INSTALLED. ACCESS PANELS
IN SHAFT WALLS, RATED FLOOR/CEILINGS OR RATED ROOF/CEILINGS SHALL BE SMOKE SEALED.
10. THE FRANCHISE BRAND STANDARDS DESIGN DOCUMENT SHALL BE CONSIDER AS AN INTEGRAL PART OF THE CONSTRUCTION DOCUMENTS. ALL CONTRACTORS SHALL
ENSURE THEY OBTAIN, READ, AND FAMILIARIZE THEMSELVES WITH THE BRAND STANDARD DOCUMENT BEFORE BIDDING AND ALSO THROUGHOUT THE CONSTRUCTION
STAGES. IF THERE ARE ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND THE FRANCHISE BRAND STANDARDS, THE CONTRACTOR SHALL ISSUE AN
RFI TO THE AOR AND EOR.

SPECIFICATIONS
1. SEE SPECIFICATION FOR GENERAL BUILDING ELEMENTS, FINISHES, MATERIALS, BUILDING ACCESSORIES, TOILET AND BATHROOM ACCESSORIES, TOILET PARTITIONS
AND URINAL SCREENS, ETC UNLESS NOTED OTHERWISE. MATERIALS, PRODUCTS, SYSTEMS ETC IDENTIFIED ON THE DRAWINGS WITH "GYP-11, EXP-JT-21, ETC". REFER
TO THE SPECIFICATION FOR SPECIFIC PRODUCT SELECTIONS AND OTHER REQUIREMENTS.

DRAWINGS
1. PLANS, SECTIONS AND ELEVATIONS INDICATE SPECIFIC INFORMATION, SEE TYPICAL MOUNTING HEIGHTS, PARTITION DETAILS, DOOR DETAILS, CASEWORK TYPES AND
DETAILS, TOP TYPES, SHELF TYPES, NOTES AND TYPICAL DETAILS FOR TYPICAL INFORMATION, INSTALLATION AND CONSTRUCTION UNLESS INDICATED OTHERWISE.
N
2. ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL OTHER DRAWINGS, PROJECT MANUAL/SPECIFICATION, PROJECT PRODUCT MANUAL, THESE NOTES, DRAWING
SYMBOLS, MATERIAL LEGEND, REFLECTED CEILING LEGEND AND GENERAL INFORMATION ON THIS SHEET AND ABBREVIATIONS.
3. DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS ONLY. VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. VERIFY ALL DISCREPANCIES BETWEEN
H2S-MEDFORD,OR
11/30/2022 8:26:01
8:26:45 PM
FIELD CONDITIONS AND THE CONTRACT DOCUMENTS. IN THE EVENT OF DISCREPANCY, NOTIFY THE ARCHITECT AND/OR ENGINEER TO OBTAIN RESOLUTION BEFORE
PROCEEDING. FAILURE TO NOTIFY THE ARCHITECT AND/OR ENGINEER WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO PERFORM THE WORK AS INTENDED
BY THE CONTRACT DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL WORK ARISING FROM SUCH FAILURE TO COORDINATE DISCREPANCIES TO
MEDFORD, OR OWNER:
THE SATISFACTION OF THE ARCHITECT.

DIMENSIONS
1. DIMENSIONS ARE SHOWN TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY, GRID/COLUMN LINE, CENTERLINE OF ELEMENT, COUNTERTOP EDGE,
OR AS NOTED.
2. DIMENSION NOTED AS CLEAR, ARE FROM WALL FINISH TO WALL FINISH.
3. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS, DO NOT SCALE DRAWINGS, NOTIFY ARCHITECT, IN WRITING, OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH
SITE ZONING: C-R/RZ
THE WORK. SITE ACREAGE: 2.67 ACRES
VERIFY CONDITIONS
1. VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK TO LOCATE ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE CONTRACT BUILDING STORIES: 4 STORIES 10655 N.E. 4th Street, Suite 606 |
DOCUMENTS. IN THE EVENT OF DISCREPANCY, NOTIFY THE ARCHITECT AND OBTAIN RESOLUTION BEFORE PROCEEDING. FAILURE TO NOTIFY THE ARCHITECT WILL NOT Bellevue, WA 98004
RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO PERFORM THE WORK AS INTENDED BY THE CONTRACT DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY AND ALL WORK ARISING FROM SUCH FAILURE TO COORDINATE DISCREPANCIES TO THE SATISFACTION OF THE ARCHITECT.
BUILDING HEIGHT LIMITATION: 55' - 8"
COORDINATION
BUILDING HEIGHT: 45' - 5 1/2" [email protected]
1. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE ENTIRE PROJECT INCLUDING ALL BUILDING ELEMENTS, SITE, EQUIPMENT, FITTINGS, FIXTURES,
FURNITURE, MECH AND ELEC ITEMS.
P:(425) 598-8516
2. VERIFY AND COORDINATE THE FOLLOWING WITH THE RESPECTIVE DISCIPLINES AND TRADES: PROJECT INFORMATION:
A. VERIFY ALL EXISTING CONDITIONS, SIZES AND LOCATIONS OF MECH AND/OR ELEC PENETRATIONS PRIOR TO COMMENCEMENT OF ANY WORK.
B. LOCATIONS FOR BACKING/BLOCKING REQUIRED FOR MOUNTING ARCH, MECH AND/OR ELEC EQUIPMENT, OWNER FURNISHED EQUIPMENT, FURNITURE, ARTWORK
AND SYSTEMS.
C. CUTTING AND PATCHING FOR WORK REQUIRED BY MECH AND/OR ELEC.
D. SIZES AND LOCATIONS OF MECH AND/OR ELEC CONCRETE CURBS AND HOUSE KEEPING PADS. SEE ALSO TYPICAL INTERIOR CONCRETE DETAILS UNO.
PROJECT DIRECTORY ROOM DATA ACCESSIBILITY DATA
E. SIZES AND LOCATIONS OF MECH AND/OR ELEC EXTERIOR WALL, CEILING AND ROOF EQUIPMENT, DEVICES AND PENETRATIONS.
OWNER: ARCHITECT: INTERIOR DESIGN
LIFE SAFETY
KAURI INVESTMENTS BASE4 INTERNATIONAL -
ROOM MATRIX TABLE 1107.6.1.1 - IBC
1. LIFE SAFETY PLANS INDICATE FIRE AND SMOKE RATED PARTITIONS, SEE LIFE SAFETY PLANS FOR PARTITION RATING AND ASSEMBLY DETAILS FOR PARTITION TYPES
Kent Agier Ricardo J. Muniz-Guillet, AIA ROOM NAME LEVEL ROOM COUNT
AND CONSTRUCTION.
2. ALL SLEEVES, OPENINGS, PENETRATIONS, ETC. FOR CONDUITS, CABLE TRAYS, PIPES AND DUCTS, ETC. THROUGH RATED PARTITIONS, FLOORS AND ROOF SLABS ARE TO 10655 N.E. 4th Street, Suite 2030 Habersham Trce 1ST FLOOR ACCESSIBLE DWELLING AND SLEEPING UNITS
BE FIRE STOPPED IN ACCORDANCE WITH THE REQUIRED FIRE RATED ASSEMBLY DESIGN, APPLICABLE CODES AND LOCAL FIRE AUTHORITY REQUIREMENTS. 606 | Bellevue, WA 98004 Cumming, GA 30041
3. ALL FIRE EXITS SHALL BE KEPT CLEAR AND ACCESSIBLE AT ALL TIMES. KING ONE BEDROOM SUITE 1ST FLOOR 1 MEDFORD, OR
P:(425) 598-8516 954.812.6650 TOTAL NUMBER MINIMUM REQUIRED NUMBER OF MINIMUM REQUIRED NUMBER OF TOTAL NUMBER OF
[email protected] [email protected] KING ONE BEDROOM SUITE ACC(RIS) 1ST FLOOR 1 OF UNITS ACCESSIBLE UNITS WITHOUT ACCESSIBLE UNITS WITH REQUIRED ACCESSIBLE
SPRINKLER SYSTEM
KING STUDIO SUITE 1ST FLOOR 5 PROVIDED ACCESSIBLE SHOWERS ACCESSIBLE SHOWERS UNITS
1. SPRINKLER HEADS SHOWN ON THE RCP'S ARE THOSE OF DESIGN CONCERN. ALL AREAS ARE REQUIRED TO BE SPRINKLERED. SPRINKLER HEADS AT GYPSUM BOARD
CEILINGS MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. STRUCTURAL: MEP: FIRE PROTECTION / ALARM: KING STUDIO SUITE CONN. 1ST FLOOR 9
BASE4 INTERNATIONAL BASE4 INTERNATIONAL BASE4 INTERNATIONAL QUEEN QUEEN STUDIO SUITE 1ST FLOOR 3
1 to 25 1 0 1 Prototype Version 3.0
ROOM OPENINGS
Allen Ramirez, PE Garry Vermaas, PhD, PE Garry Vermaas, PhD, PE 19 19
26 to 50 2 0 2 August 2022
1. FLOOR PLANS INDICATE ROOM OPENING NUMBERS. FOR DOOR AND DOOR BORROWED LIGHT FRAME TYPES, FRAME PROFILES, NOTES AND TYPICAL DETAILS, SEE ROOM
DOOR SCHEDULE AND A712. 16916 Hutchins Landing, 2183 S. Berrys Chapel Road 2183 S. Berrys Chapel Road 2ND FLOOR 51 to 75 3 1 4
2. LOCATE DOORS AND OTHER OPENINGS IN PARTITIONS ADJACENT TO PERPENDICULAR WALLS. MAINTAIN MINIMUM ACCESSIBILITY DOOR LATCH SIDE CLEARANCE Units 80 Franklin, TN 37069 Franklin, TN 37069 76 to 100 4 1 5 ISSUE
KING ONE BEDROOM SUITE 2ND FLOOR 1 DELTA ISSUE DATE DESCRIPTION
REQUIREMENTS, PUSH SIDE 12" MIN. 4'-0" DEEP IF DOOR IS PROVIDED WITH A CLOSER AND PULL SIDE 1'-6" MIN. 4'-0" DEEP IF DOOR IS PROVIDED WITH A CLOSER. San Diego, CA 92127 615.613.3605 615.613.3605 NO.
[email protected] [email protected] KING ONE BEDROOM SUITE ACC(TUB) 2ND FLOOR 1 101 to 150 5 2 7
CASEWORK AND MILLWORK KING STUDIO SUITE 2ND FLOOR 5 151 to 200 6 2 8
1. CASEWORK TYPES, TOP TYPES, SHELF TYPES, NOTES AND SPECIFIC DETAILS ARE AS SHOWN ON PLANS AND INTERIOR ELEVATIONS, SEE A930 FOR TYPICAL COUNTER 1 A1 2022.11.30 ISSUED FOR
CIVIL: LANDSCAPE: KING STUDIO SUITE CONN. 2ND FLOOR 9 201 to 300 7 3 10
TOP TYPES, UNDERCOUNTER TASK LIGHTING, SUPPORT BRACKET TYPES, COUNTER TOP CORNER, GROMMET, GYP/PLAM SOFFIT TYPES, NOTES AND DETAILS, ROOM PERMIT
FINISHES SCHEDULE AND/OR FINISHES PLANS. THORNTON ENGINEERING MADARA DESIGN INC QUEEN QUEEN STUDIO SUITE 2ND FLOOR 15 301 to 400 8 4 12
2. CASEWORK FINISHES, SEE ROOM FINISHES SCHEDULE AND NOTES. Michael Thornton Tom Madara QUEEN QUEEN STUDIO SUITE CONN. 2ND FLOOR 1 401 - to 500 9 4 13
260 N Third Street, PO Box M. 541-944-4287 | QUEEN QUEEN STUDIO SUITE- ACC. CONN.(RIS) 2ND FLOOR 1
ROOM FINISHES 501 to 1,000 2% of total 1% of total 3% of total
1. FINISHES ARE INDICATED IN THE FINISH SCHEDULE AND/OR FINISH PLANS, SEE TYPICAL FINISH TRANSITION DETAILS.
476, Jacksonville, OR 97530 O. 541-664-7055
(541) 899-1489 [email protected] 33 33
20, plus 1 for each 100, 10 plus 1 for each 100, or 30 plus 2 for each 100, or
FLOOR DRAINS [email protected] 3RD FLOOR over 1,000
or fraction thereof, over 1,000 fraction thereof, over 1,000 fraction thereof, over 1,000
1. SET FLOOR DRAINS AND FLOOR SINKS WITH TOP OF FINISH TILE/POURED FLOOR. SEE PLUMBING DRAWINGS. KING ONE BEDROOM SUITE 3RD FLOOR 1
2. SLOPE CONCRETE FLOOR AT 1/8" PER FOOT TOWARDS FLOOR DRAINS AND AWAY FROM ALL WALLS. *The table is taken from International Building Code 2018 (IBC 2018) and is provided as a reference.
CONTRACTORS SHALL SEND ALL BIDDING QUESTIONS AND RFI’S TO THE GENERAL CONTRACTOR. THE KING ONE BEDROOM SUITE ACC(TUB) 3RD FLOOR 1
FURNITURE, EQUIPMENT, FITTING, FIXTURES AND ACCESSORIES GC SHALL THEN FORWARD INQUIRIES TO THE APPOINTED BASE4 CONSTRUCTION ADMINISTRATION KING STUDIO SUITE 3RD FLOOR 5
1. FURNITURE, EQUIPMENT, FITTING, FIXTURES AND ACCESSORIES INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS AND THE TYPICAL PROJECT MANAGER, WHO WILL BE INTRODUCED AT THE BEGINNING OF THE BIDDING AND KING STUDIO SUITE CONN. 3RD FLOOR 9
MOUNTING HEIGHT SHEET UNO.
2. REFER TO FURNITURE AND EQUIPMENT DRAWINGS AND INSTRUCTIONS FOR INSTALLATION RESPONSIBILITIES. PROVIDE ALL BLOCKING & ANCHORAGE AS NECESSARY
CONSTRUCTION PHASE. PLEASE REFERENCE THE PROJECT NUMBER AND PROJECT TITLE IN YOUR
EMAIL SUBJECT LINE TO ENSURE THAT YOUR REQUEST IS FORWARDED TO THE PROPER TEAM.
QUEEN QUEEN STUDIO SUITE 3RD FLOOR 15 TABLE 224.4 - ADA 2010
FOR PROPER INSTALLATION OF ANY WALL MOUNTED OR HUNG ITEMS, SEE PARTITION BLOCKING DETAILS. QUEEN QUEEN STUDIO SUITE CONN. 3RD FLOOR 1
CURBS AND PADS
QUEEN QUEEN STUDIO SUITE- ACC. CONN.(TUB) 3RD FLOOR 1 GUEST ROOMS WITH COMMUNICATION FEATURES
1. CONCRETE CURBS AND PADS FOR EQUIPMENT. LOCATIONS MAY BE NOTED ON THE ARCHITECTURAL AND/OR CIVIL DRAWINGS. SEE MECHANICAL AND ELECTRICAL 33 33
DRAWINGS FOR LOCATIONS AND SPECIFIC SIZE AND CONFIGURATION OF THE EQUIPMENT TO CONFIRM SIZE OF PAD OR CURB, PRIOR TO INSTALL. 4TH FLOOR TOTAL NUMBER OF GUEST
2. GC SHALL CONTACT AND COORDINATE WITH LOCAL MUNICIPALITY FOR SITE OR EQUIPMENT SPECIFIC REQUIREMENTS FOR CURB AND PADS. INTERIOR DESIGN INFORMATION KING ONE BEDROOM SUITE 4TH FLOOR 1 ROOMS PROVIDED
MINIMUM NUMBER OF REQUIRED GUEST ROOMS WITH COMMUNICATION FEATURES
PARTITIONS KING ONE BEDROOM SUITE ACC(TUB) 4TH FLOOR 1
1 to 25 2
1. ALIGN PARTITIONS WITH FACE OF OTHER PARTITIONS OR COLUMNS, UNLESS NOTED OTHERWISE. THE FACE OF EVERY PARTITION SHALL BE FLUSH WITHOUT OFFSETS.
CHANGES IN PARTITION THICKNESS SHALL OCCUR AT CORNERS, PARTITION INTERSECTIONS OR OTHER FEATURES WHICH INTERRUPT THE PLANE OF THE PARTITION. ID SCOPE: LEVEL-0 KING STUDIO SUITE
KING STUDIO SUITE CONN.
4TH FLOOR
4TH FLOOR
5
9
26 to 50 4
FACE OF CORRIDOR PARTITIONS SHALL BE FLUSH FOR THE ENTIRE LENGTH OF THE CORRIDOR REGARDLESS OF CHANGES IN PARTITION THICKNESS, ALL ADJUSTMENTS
SHALL BE MADE TO THE ROOM SIDE OF THE CORRIDOR PARTITION AND AT CORNERS.
2. FLOOR PLANS INDICATE PARTITION TYPES, SEE PARTITION NOTES AND DETAILS FOR TYPICAL CONSTRUCTION UNLESS INDICATED OTHERWISE.
FRANCHISE DOCUMENT: Prototype Version 3.0 KING SUITE ACC. CONN.(TUB) 4TH FLOOR 1 51 to 75 7
QUEEN QUEEN STUDIO SUITE 4TH FLOOR 15 76 to 100 9
WALL BLOCKING AND ANCHORAGE
August 2022 QUEEN QUEEN STUDIO SUITE CONN. 4TH FLOOR 1 101 to 150 12
1. PROVIDE PLYWOOD WALL BLOCKING WHERE ARTWORK, MARKER BOARDS (MBD) AND TACKBOARDS (TBD) ARE SHOWN. EXTENT OF BLOCKING TO MATCH SIZE OF
ARTWORK, MARKER BOARDS (MBD) AND TACKBOARDS (TBD). SEE PARTITION BLOCKING DETAILS. PROTOTYPE SCHEME: Specified by Owner 33
GRAND TOTAL
33
118
151 to 200 14
2. PROVIDE WALL BLOCKING FOR FURNITURE, EQUIPMENT, FITTINGS, FIXTURES AND ACCESSORIES IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS AND 201 to 300 17
REQUIREMENTS. SEE PARTITION BLOCKING DETAILS. DESIGN LOAD FOR FITTINGS AND FIXTURES MUST INCLUDED MIN, 250 LB VERTICAL AND HORIZONTAL FORCES.
301 to 400 20
WALL PROTECTION ROOM MIX 401 - to 500 22
CURRENT ISSUE:
1. CORNER GUARDS AND OTHER WALL PROTECTION TYPES AS INDICATED ON THE DRAWINGS.
2. CORNER GUARDS ARE MOUNTED ABOVE FLOOR FINISH BASE AND UP TO UNDERSIDE OF CEILING OR CEILING BULKHEAD, WHICH EVER IS APPLICABLE.
GROSS AREA SCHEDULE ROOM NAME ROOM COUNT ROOM MIX 501 to 1,000 5% of total
3. FOR INSTALLATION OF CORNER GUARDS, WALL PROTECTION, HANDRAILS, CRASH RAILS, ETC, SEE MANUFACTURERS INSTRUCTIONS. KING ONE BEDROOM SUITE 4 3%
CEILINGS
*COVERED OUTDOOR SPACES EXCLUDED
LEVEL AREA KING ONE BEDROOM SUITE ACC(RIS) 1 1% over 1,001
50, plus 3 for each 100,
or fraction thereof, over 1,000
ISSUE FOR PERMIT
1. CEILING HEIGHT: SEE RCP FOR GUESTROOMS, ELEVATOR LOBBIES, CORRIDORS, PASSAGES, ETC. ABOVE FLOOR LEVEL UNLESS OTHERWISE NOTED. SEE ALSO ROOM 1ST FLOOR 19,587 SF KING ONE BEDROOM SUITE ACC(TUB) 3 3%
*The table is taken from ADA Standards for Accessible Design 2010 (ADA 2010) and is provided as a reference.
FINISH SCHEDULE. KING STUDIO SUITE 20 17%
2. COORDINATE AND VERIFY ALL CEILING ACCESS PANEL SIZES AND LOCATIONS WITH MECH AND ELEC CONTRACTORS. PROVIDE FLUSH ACCESS PANELS AT ALL 2ND FLOOR 17,843 SF
KING STUDIO SUITE CONN. 36 31% CURRENT ISSUE DATE:
EQUIPMENT, VALVES, DAMPERS, CONTROLS, CLEANOUTS, ETC. PAINT TO MATCH CEILING FINISH.. 3RD FLOOR 17,843 SF
3. CENTER CEILING GRID IN ROOM UNLESS NOTED OTHERWISE. KING SUITE ACC. CONN.(TUB) 1 1%
4. CENTER SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, AND OTHER RECESSED OR SURFACE MOUNTED ITEMS IN CEILING TILES UNLESS NOTED OTHERWISE.
4TH FLOOR
TOTAL: 4
17,843 SF
73,117 SF QUEEN QUEEN STUDIO SUITE 48 41%
ACC. ROOM MATRIX COMM. FEATURE... 2022.11.30
DRAWN BY:
FIRE PROTECTION REQUIREMENTS QUEEN QUEEN STUDIO SUITE CONN. 3 3% ROOM NAME ROOM NUMBER ROOM NAME ROOM NUMBER
1. GC SHALL PERFORM AND PROVIDE ALL FIRE PROTECTION AS REQUIRED BY CODE, WHETHER OR NOT ALL REQUIREMENTS ARE INDICATED ON THE DRAWINGS.
2. FIRE PROTECTION SHALL INCLUDE BUT NOT BE LIMITED TO: FIRE SUPPRESSION SYSTEMS, PARTITIONS, FLOOR ASSEMBLIES, ROOFS, STRUCTURAL STEEL, GLAZING,
QUEEN QUEEN STUDIO SUITE- ACC. CONN.(RIS) 1 1% PJ/RG
CONCEALED SPACES, ETC. AS INDICATED IN BUILDING CODE EVALUATION SUMMARY SHEET. QUEEN QUEEN STUDIO SUITE- ACC. CONN.(TUB) 1 1% KING ONE BEDROOM SUITE 117 KING STUDIO SUITE 108
CHECKED BY:
3. REFER TO BCES TABLE 601 FOR REQUIRED FIRE RESISTANCE RATINGS OF MAIN BUILDING ELEMENTS. GRAND TOTAL 118 100% ACC(RIS) KING STUDIO SUITE CONN. 111
4. REFER TO ASSEMBLY SHEETS AND DETAILS FOR ADDITIONAL FIRE PROTECTION REQUIREMENTS REFER TO ASSEMBLY SHEETS AND DETAILS FOR ADDITIONAL FIRE KING ONE BEDROOM SUITE 217 LA/RB
PROTECTION REQUIREMENTS.
KING ONE BEDROOM SUITE 117
ACC(TUB) ACC(RIS)
5. GC SHALL NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR QUESTIONS IN FIRE PROTECTION DOCUMENTATION PRIOR TO PROCEED. PROJECT #:
QUEEN QUEEN STUDIO SUITE- ACC. 238 QUEEN QUEEN STUDIO SUITE 124
ELEVATOR SMOKE CURTAIN MAINTENANCE (IF APPLICABLE) CONN.(RIS) KING ONE BEDROOM SUITE 206 B4-250-2101
1. ROLLING MAGNETIC GASKETING SYSTEMS ARE MAINTAINED BY FACILITY MANAGERS OR MAINTENANCE STAFF. EVERY SIX MONTHS THE SYSTEM SHOULD BE DEPLOYED
KING ONE BEDROOM SUITE 317 QUEEN QUEEN STUDIO SUITE 221
AND REWOUND TO ENSURE FUNCTIONALITY. IT DOES NOT REQUIRE OVERSIGHT FROM AN ENGINEER OR LICENSED THIRD PARTY INSPECTOR AND THE UNITS SHEET NAME:
THEMSELVES ARE HIDDEN IN A HOUSING ABOVE THE ELEVATOR DOOR, REMOVING THEM FROM VIEW AND MAKING IT LESS LIKELY THAT THEY WILL BE SUBJECT TO ACC(TUB)
KING STUDIO SUITE CONN. 301
TAMPERING. QUEEN QUEEN STUDIO SUITE- ACC. 338
KING STUDIO SUITE 312
ELEVATOR SELECTION, SIZE, SPECIFICATION AND REQUIRED SHOP DRAWING SUBMITTAL
1. ELEVATOR PIT/SHAFT DIMENSIONS AND CAPACITY/SPEED ARE BASIS OF DESIGN SPECIFICATION ONLY. GC SHALL COORDINATE WITH OWNER AND SUBMIT ELEVATOR
CONN.(TUB)
KING ONE BEDROOM SUITE 417
QUEEN QUEEN STUDIO SUITE
CONN.
336 PROJECT
SHOP DRAWINGS/SPECIFICATIONS TO BASE4, AS SOON AS POSSIBLE BUT NO LATER THAN PRIOR TO INITIAL MUNICIPAL FILING COMMENTS RESUBMITTAL. ACC(TUB)
KING SUITE ACC. CONN.(TUB) 438
KING STUDIO SUITE 414 INFORMATION
REQUEST FOR SUBSTITUTION QUEEN QUEEN STUDIO SUITE 423
1. OWNER/GC REQUESTS FOR SUBSTITUTION (RFS) SHALL BE PERMITTED ONLY FOR ITEMS DEEMED AS OPEN SPECIFICATION IN PROJECT MANUAL (indicated as OR EQUAL).
2. IF BRAND APPROVAL IS REQUIRED FOR RFS GC SHALL SECURE BRAND APPROVAL IN ADVANCE OF SUBMISSION TO ARCHITECT.
GRAND TOTAL: 7
QUEEN QUEEN STUDIO SUITE 433 AND GENERAL
GRAND TOTAL: 12
BLOCKING
1. GC SHALL PROVIDE ALL ADDITIONAL, NON-PROTOTYPICAL BLOCKING (NOT SHOWN IN ELEVATIONS) AS REQUIRED TO ENSURE ADEQUATE FASTENING OF RELATED
NOTES
ELEMENT (SHOWER ROD, SHELVING, SIGNAGE, ETC..)
SHEET NUMBER:

G-002
0" 1"
CODE SUMMARY - 2019 Oregon Structural Specialty Code (OSSC) 2018 IBC
PROJECT INFORMATION CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES CHAPTER 29: PLUMBING SYSTEMS
PROJECT ADDRESS 713.4 Fire-resistance rating. SECTION 2902 MINIMUM PLUMBING FACILITIES
Shaft enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four stories or more, and not less than
MEDFORD, OR 1 hour where connecting less than four stories. The number of stories connected by the shaft enclosure shall include any basements 2902.1 Minimum Number of Fixtures.
but not any mezzanines. Shaft enclosures shall have a fire-resistance rating not less than the floor assembly penetrated, but need Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 2902.1. Uses not 2901 Clint Moore Rd, #114
not exceed 2 hours. Shaft enclosures shall meet the requirements of Section 703.2.1. shown in Table 2902.1 shall be determined individually by the building official based on the occupancy which most nearly
resembles the proposed occupancy. The number of occupants shall be determined by this code. Plumbing fixtures need not be
Boca Raton, FL 33496
718.3 Draftstopping in floors. provided for unoccupied buildings or facilities. 888.901.8008 www.base-4.com
In combustible construction, Draftstopping shall be installed to subdivide floor/ceiling assemblies in the locations prescribed in
APPLICABLE CODES Sections 718.3.2 through 718.3.3. ARCHITECT:

TABLE 2902.1 - IBC Ricardo J. Muniz-Guillet, AIA


BUILDING CODE MECHANICAL CODE Exceptions:
1. Draftstopping is not required in buildings equipped throughout with an automatic sprinkler system in accordance with Section ENERGY CODE INFORMATION 2030 Habersham Trce
⚫ 2019 Oregon Structural Specialty Code (OSSC) 2018 IBC ⚫ 2019 Oregon Mechanical Speciality Code (Based on 2019
International Mechanical Code and International GAS Code)
903.3.1.1. MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES Cumming, GA 30041

CHAPTER 9: FIRE PROTECTION SYSTEMS CLASSIFICATION WATER CLOSET LAVATORIES DRINKING


OTHER
2021 Oregon Energy Efficiency Specialty 954.812.6650
[email protected]
& OCCUPANCY FOUNTAINS
ACCESSIBILITY CODE
⚫ ICC A117.1-2009 Accessible and Usable Buildings and
ELECTRICAL CODE
⚫ 2021 Oregon Electrical Specialty Code ( Based on 2020
FIRE PROTECTION PLUMBING: STANDPIPES A-2 ASSEMBLY
MALE FEMALE
1 PER 75
MALE FEMALE
1 PER 200 1 PER 500 1 SERVICE SINK Code ASHRAE Standard 90.1-2019
SPRINKLER SYSTEM: FULLY SPRINKLED A-3 ASSEMBLY 1 PER 125 1 PER 65 1 PER 200 1 PER 1,000 1 SERVICE SINK
Facilities NFPA / National Electric Codes)
AN APPROVED AUTOMATIC SPRINKLER SYSTEM SPECIFIED FOR THIS PROJECT SHALL BE DESIGNED AND
INSTALLED IN ACCORDANCE WITH SECTION 903 B BUSINESS
1 PER 25 FOR THE FIRST 50
AND 1 PER 50 FOR THE
1 PER 40 FOR THE FIRST 80
AND 1 PER 80 FOR THE 1 PER 100 1 SERVICE SINK
CHAPTER 3: [CE] GENERAL REQUIREMENTS
FIRE CODE PLUMBING CODE REMAINDER EXCEEDING 50 REMAINDER EXCEEDING 80
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS SECTION C301 CLIMATE ZONES
⚫ 2019 Oregon Fire Code (NFPA 13) See Appendix "N" OSSC ⚫ 2021 Plumbing Speciality Code (Based on 2021 Uniform M MERCANTILE 1 PER 500 1 PER 750 1 PER 1,000 1 SERVICE SINK
and Appendix "D" OMSC, 2018 IFC Plumbing Code) 903.2 Where required. C301.1 General.
R-1 RESIDENTIAL 1 PER SLEEPING UNIT 1 PER SLEEPING UNIT 1 SERVICE SINK
Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections -
903.2.1 through 903.2.12. R-2 RESIDENTIAL 1 PER DWELLING UNIT 1 PER DWELLING UNIT 1 SERVICE SINK CLIMATE ZONE: 4C JACKSON, OREGON
ENERGY CONSERVATION CODE FUEL GAS CODE Exception: S-1 STORAGE See Section 411 of
1. Spaces or areas in telecommunications buildings used exclusively for telecommunications equipment, associated electrical 1 PER 100 1 PER 100 the International 1 SERVICE SINK
⚫ 2021 Oregon Energy Efficiency Specialty Code ASHRAE
Standard 90.1-2019
⚫ 2019 Oregon Fuel Gas Code ( Based on the International
Fuel Gas Code)
power distribution equipment, batteries and standby engines, provided those spaces or areas are equipped throughout with an S-2 STORAGE Plumbing Code CHAPTER 4: [CE] GENERAL REQUIREMENTS
automatic smoke detection system in accordance with Section 907.2 and are separated from the remainder of the building by not
less than 1-hour fire barriers constructed in accordance with Section 707 or not less than 2-hour horizontal assemblies NOTE: This table is provided as a reference only. For a complete table please refer to table 2902.1 of the International Building SECTION C402 BUILDING ENVELOPE REQUIREMENTS
constructed in accordance with Section 711, or both. Code.
C402.1.3 Insulation Component R -Value-Based Method.
CHAPTER 3: OCCUPANCY USE AND CLASSIFICATION 903.2.11.4 Ducts conveying hazardous exhausts. C402.1.4 Assembly U-factor, C-factor or F-factor-based method.
11/30/2022 8:26:01
8:26:54 PM
Where required by the International Mechanical Code, automatic sprinklers shall be provided in ducts conveying hazardous exhaust
OWNER:
MAIN OCCUPANCY: or flammable or combustible materials. TABLE C402.1.3 & TABLE C402.1.4 - OPAQUE THERMAL ENVELOPE
R1 RESIDENTIAL HOTEL ROOM
Exception: Ducts where the largest cross-sectional diameter of the duct is less than 10 inches (254 mm). PLUMBING FIXTURE CALCULATION INSULATION COMPONENT MINIMUM REQUIREMENTS
SECTION 906 PORTABLE FIRE EXTINGUISHERS NOTE: WATER CLOSET & LAVATORY REQUIREMENTS FOR RESIDENTIAL R-1 & R-2 (APARTMENT HOUSE)
OCCUPANCIES: 1 PER EACH GUESTROOM / UNIT ROOFS
OTHER OCCUPANCIES: 906.1 Where required. - INSULATION ENTIRELY ABOVE DECK R-30 ci (U-0.032)
CLASSIFICATION & OCCUPANT WATER CLOSETS LAVATORIES DRINKING
A2 ASSEMBLY - KITCHEN LOBBY / LOUNGE / BREAKROOM Portable fire extinguishers shall be installed in all of the following locations: AREA - ATTIC AND OTHER R-49 (U-0.021)
1. In Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. OCCUPANCY LOAD MALE FEMALE MALE FEMALE FOUNTAINS
A2 ASSEMBLY - W/O KITCHEN LOBBY / LOUNGE / BREAKROOM
A3 ASSEMBLY FITNESS ROOM / POOL WALLS, ABOVE GRADE
906.2 General Requirements. A2 ASSEMBLY - KITCHEN 350.66 SF 2.00 0.01 0.01 0.01 0.01 0.00 10655 N.E. 4th Street, Suite 606 |
B BUSINESS OFFICE AREAS - WOOD FRAMED AND OTHER R-13 + R-7.5ci
Portable fire extinguishers shall be selected and installed in accordance with this section and NFPA 10. A2 ASSEMBLY - W/O 4141.81 Bellevue, WA 98004
M MERCANTILE MARKET 278.00 1.95 1.95 0.77 0.77 0.61
KITCHEN SF WALLS, BELOW GRADE
S1 STORAGE STORAGE 906.4 Cooking grease fires. A3 ASSEMBLY 1812.79 - BELOW-GRADE WALL
S2 STORAGE STORAGE Fire extinguishers provided for the protection of cooking grease fires shall be of an approved type compatible with the automatic fire- SF
38.00 0.15 0.29 0.10 0.10 0.04 R-7.5 ci (C-0.119) [email protected]
extinguishing system agent and in accordance with Section 906.1, item 2, 906.4.1 and 906.2 of the International Fire Code, as
B BUSINESS 720.33 SF 8.00 0.16 0.16 0.10 0.10 0.08 P:(425) 598-8516
applicable. FLOORS
CHAPTER 4: SPECIAL DETAILED REQUIREMENTS S1 STORAGE 921.61 SF 5.00 0.03 0.03 0.03 0.03 0.01 - JOIST / FRAMING R-30 (U-0.033) PROJECT INFORMATION:
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS TOTALS: 7947.2 SF 331.00 2.30 2.44 0.99 0.99 0.74
BASED ON OCCUPANCY AND USE
907.2.8 Group R-1. SLAB-ON-GRADE FLOORS
SECTION 420 GROUPS I-1, R-1, R-2, R-3 Fire alarm systems and smoke alarms shall be installed in Group R-1 occupancies as required in Sections 907.2.8.1 through - UNHEATED SLABS R-15 for 24” (F-0.520)
907.2.8.3.
420.1 General.
Occupancies in Groups I-1, R-1, R-2,R-3 and R-4 shall comply with the provisions of Sections 420.1 through 420.11 and other
CHAPTER 10: MEANS OF EGRESS
applicable provisions of this code. OPAQUE DOORS
SECTION 1004 OCCUPANT LOAD - NONSWINGING DOOR U-0.310
420.2 Separation walls. - SWINGING DOOR U-0.370
Walls separating dwelling units in the same building, walls separating sleeping units in the same building and walls separating 1004.1 Design Occupant Load. - GARAGE DOOR < 14% GLAZING MEDFORD, OR
dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as fire partitions in In determining means of egress requirements, the number of occupants for whom means of egress facilities are provided shall be determined in accordance with this
accordance with Section 708. section.
C402.2 Fenestration.
Prototype Version 3.0
420.3 Horizontal separation.
Floor assemblies separating dwelling units in the same buildings, floor assemblies separating sleeping units in the same building and
TABLE 1004.5 - IBC AREA OCCUPANCY - 1ST FLOOR TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM August 2022
floor assemblies separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be OCCUPANCY OCCUPANT OCCUPANT EGRESS EGRESS WIDTH U-FACTOR AND SHGC REQUIREMENTS
constructed as horizontal assemblies in accordance with Section 711. MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT AREA LOAD FACTOR LOAD FACTOR REQUIRED ISSUE
NO.
DELTA ISSUE DATE DESCRIPTION
A2 ASSEMBLY - KITCHEN VERTICAL FENESTRATION
420.4 Automatic sprinkler system. OCCUPANCY GROUP FUNCTION OF SPACE OCCUPAND LOAD FACTOR
350.66 SF 200 2 0.2 0.4 U-FACTOR
Group R occupancies shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.2.8. Group R-1 RESIDENTIAL 200 GROSS 1 A1 2022.11.30 ISSUED FOR
A2 ASSEMBLY - W/O KITCHEN - FIXED FENESTRATION U-0.36
I-1 occupancies shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.2.6. Quick- A ASSEMBLY - UNCONCENTRATED 15 NET PERMIT
4400.9 SF 15 297 0.2 59.4 - OPERABLE FENESTRATION U-0.45
response or residential automatic sprinklers shall be installed in accordance with Section 903.3.2.
A SWIMMING POOL 50 GROSS A3 ASSEMBLY - ENTRANCE DOORS U-0.63
420.5 Fire alarm systems and smoke alarms. A KITCHEN 200 GROSS 2184.34 SF 50 48 0.2 9.6 SHGC
Fire alarm systems and smoke alarms shall be provided in Group I-1, R-1 and R-2 occupancies in accordance with Sections 907.2.6, B BUSINESS 100 GROSS B BUSINESS - PF < 0.2
907.2.8 and 907.2.9, respectively. Single-or multiple-station smoke alarms shall be provided in Groups I-1, R-2, R-3 and R-4 in - 0.2 ≤ PF < 0.5
S-1 STORAGE 300 GROSS 887.77 SF 100 10 0.2 2
accordance with Section 907.2.11. - PF ≥ 0.5 U-0.36
*Provided above are the applicable occupancies for this project only. For full table please refer to IBC R1 RESIDENTIAL
8695.44 SF 200 46 0.2 9.2 SKYLIGHTS
SECTION 1005 MEANS OF EGRESS SIZING
CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS S1 STORAGE - U-FACTOR U-0.50
1005.3.1 Stairways. 921.61 SF 300 5 0.2 1 - SHGC U-0.40
CONSTRUCTION SUMMARY The capacity, in inches, of means of egress stairways shall be calculated by multiplying the occupant load served by such stairways by a means of egress capacity 17440.72 SF 408 81.6
factor of 0.3 inch (7.6 mm) per occupant. Where stairways serve more than one story, only the occupant load of each story considered individually shall be used in
MAIN OCCUPANCY: R1 RESIDENTIAL BUILDING STORIES: 4 STORIES calculating the required capacity of the stairways serving that story.
DEVELOPMENT TYPE:
SPRINKLER SYSTEM:
NEW CONSTRUCTION
FULLY SPRINKLED
CONSTRUCTION:
BUILDING USAGE:
NEW CONSTRUCTION
HOTEL
Exceptions: SEATING OCCUPANCY - 1ST FLOOR
1. For other than Group H and I-2 occupancies, the capacity, in inches, of means of egress stairways shall be calculated by multiplying the occupant load served by
such stairways by a means of egress capacity factor of 0.2 inch (5.1 mm) per occupant in buildings equipped throughout with an automatic sprinkler system LINEAR OCCUPANT OCCUPANT EGRESS EGRESS WIDTH
CONSTRUCTION TYPE: TYPE V-A INCHES LOAD FACTOR LOAD FACTOR REQUIRED
installed in accordance with Section 903.3.1.1 or 903.3.1.2 and an emergency voice/alarm communication system in accordance with Section 907.5.2.2.
2. Facilities with smoke-protected assembly seating shall be permitted to use the capacity factors in Table 1030.6.2 indicated for stepped aisles for exit access or exit BAR / BENCH SEATING
stairways where the entire path for means of egress from the seating to the exit discharge is provided with a smoke control system complying with Section 909. 297" 1 PERSON / 18" 17 0.2 3.4
TABLE 504.3 - ALLOWABLE BUILDING HEIGHT 3. Facilities with open-air smoke-protected assembly seating shall be permitted to the capacity factors in Section 1030.6.3 indicated for stepped aisles for exit access BOOTH SEATING
ALLOWABLE BUILDING HEIGHT: 70' - 0" or exit stairways where the entire path for means of egress from the seating to the exit discharge is open to the outdoors.
333" 1 PERSON / 24" 16 0.2 3.2
BUILDING HEIGHT: 45' - 5 3/8" 630" 33 6.6
TALLEST PARAPET: 11' - 1 1/8" SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
TOTAL BUILDING HEIGHT: 56' - 6 1/2" 1006.3.1 Egress Based on Occupant Load.
TOTAL OCCUPANCY - 1ST FLOOR
OCCUPANT LOAD PER STORY: 1 - 500
TABLE 504.4 - ALLOWABLE NUMBER OF STORIES TOTAL EXITS REQUIRED: 2 OCCUPANCY TOTAL OCCUPANT EGRESS TOTAL EGRESS WIDTH
TYPE LOAD FACTOR REQUIRED CURRENT ISSUE:
ALLOWABLE NUMBER OF STORIES: 5
TOTAL EXITS PROVIDED: AREA TOTAL 409 AS INDICATED 81.8
PROPOSED BUILDING STORIES: 4
SEATING TOTAL 33 AS INDICATED 6.6
GROUND FLOOR: 4
GRAND TOTAL 442 88.4 ISSUE FOR PERMIT
UPPER FLOORS: 2
EGRESS WIDTH PROVIDED : (36'' x 5 EXITS) = 180''
TABLE 506.2 - ALLOWABLE AREA FACTOR
ALLOWABLE AREA FACTOR: 36000 SF SECTION 1008 MEANS OF EGRESS ILLUMINATION CURRENT ISSUE DATE:

GROSS AREA SCHEDULE 1008.1 Means of Egress Illumination.


Illumination shall be provided in the means of egress in accordance with Section 1008.2. Under emergency power, means of egress illumination shall comply with AREA OCCUPANCY - UPPER FLOORS 2022.11.30
*COVERED OUTDOOR SPACES EXCLUDED DRAWN BY:
Section 1008.3. OCCUPANCY OCCUPANT OCCUPANT EGRESS EGRESS WIDTH
LEVEL AREA AREA LOAD FACTOR LOAD FACTOR REQUIRED PJ/RG
1ST FLOOR 19,587 SF SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
CHECKED BY:
2ND FLOOR 17,843 SF R1 RESIDENTIAL
1017.1 General
3RD FLOOR 17,843 SF Travel distance within the exit access portion of the means of egress system shall be in accordance with this section. 16511.93 SF 200 84 0.2 16.8 LA/RB
4TH FLOOR 17,843 SF S1 STORAGE PROJECT #:
TOTAL: 4 73,117 SF 1017.2 Limitations 69.55 SF 300 1 0.2 0.2
Exit access travel distance shall not exceed the values given in Table 1017.2. 16581.48 SF 85 17
B4-250-2101
CHAPTER 6: TYPES OF CONSTRUCTION SHEET NAME:
SPRINKLER SYSTEM: FULLY SPRINKLED
TABLE 601: FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING MAIN OCCUPANCY: R1 RESIDENTIAL
TOTAL OCCUPANCY - UPPER FLOORS
ELEMENTS (HOURS) OCCUPANCY TOTAL OCCUPANT EGRESS TOTAL EGRESS WIDTH
TYPE LOAD FACTOR REQUIRED
TABLE 1017.2 - IBC AREA TOTAL 10 AS INDICATED 5
CONSTRUCTION TYPE TYPE V-A
SEATING TOTAL 0 AS INDICATED 0 CODE SUMMARY
BUILDING ELEMENT RATING EXIT ACCESS TRAVEL DISTANCE GRAND TOTAL 10 5
PRIMARY STRUCTURAL FRAME 1.0 EGRESS WIDTH PROVIDED : (36'' x [1] EXITS) + (36'' x [1] EXIT) = 72''
OCCUPANCY GROUP WITHOUT SPRINKLER SYSTEM (FEET) WITH SPRINKLER SYSTEM (FEET)
BEARING WALLS - EXTERIOR 1.0
BEARING WALLS - INTERIOR 1.0 A, E, F-1, M, R, S-1 200 250 (^b)
NONBEARING WALLS & PARTITIONS - INTERIOR 0.0 b. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. See Section 903 for occupancies where automatic
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY STRUCTURAL MEMBERS 1.0 sprinkler systems are permitted in accordance with Section 903.3.1.2. SHEET NUMBER:
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY STRUCTURAL MEMBERS 1.0
Section 601 exception a states that approved automatic sprinkler system cannot be used for a reduction in rating if it has already
been used for an area increase or an allowable height increase. It also states that it cannot be used for a reduction in bearing walls.
G-003
0" 1"
ABBREVIATIONS CEILING FINISH LEGEND
ACCESSIBLE CLEARANCE LEGEND TYPE
DOOR MANEUVERING SPACE: FRONT APPROACH, PUSH SIDE CLEAR FLOOR SPACE = DOOR WIDTH X 48'' A ELEV ELEVATOR L RD ROOF DRAIN MARK DESCRIPTION
A 12'' BEYOND DOOR WIDTH AT LATCH SIDE WHEN DOOR HAS LATCH AND CLOSER A/C AIR CONDITIONING EMERR EMERGENCY LAB LABORATORY RECEP RECEPTACLE A PRIMED & PAINTED GYPSUM BOARD
A/E ARCHITECT / ENGINEER ENCL ENCLOSURE LAM LAMINATE REC'P RECEPTION B PRIMED & PAINTED GYPSUM BOARD-MOISTURE
B DOOR MANEUVERING SPACE: FRONT APPROACH, PULL SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 18'' X 60'' RESISTANT
ACT ACOUSTICAL CEILING TILE ENGR ENGINEER LAV LAVATORY REF REFRIGERATOR
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
DOOR MANEUVERING SPACE: HINGE SIDE APPROACH, PUSH SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 22'' X 42'' ADA AMERICANS WITH DISABILITIES ACT E.O.D. EDGE OF DECK LB POUND REINF REINFORCE / REINFORCED
C PUSH SIDE CLEAR FLOOR SPACE = DOOR + 22'' X 4'-0''(WHEN DOOR HAS LATCH AND CLOSER)
ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED
2901 Clint Moore Rd, #114
ADD'L ADDITIONAL EP ELECTRICAL PANEL LF LINEAR FOOT REQ'D REQUIRED MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
ADD ADDENDUM EPDM ETHYLENE, PROPYLENE, DIENE,... LH LEFT HAND REV REVISION ONLY-REFER TO SECTIONS Boca Raton, FL 33496
DOOR MANEUVERING SPACE: HINGE SIDE APPROACH, PULL SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 42'' X 54''
D ALTERNATIVE PERMISSIBLE CLEAR FLOOR SPACE = DOOR WIDTH + 36'' X 60'' ADJ ADJUSTABLE / ADJACENT EQ EQUAL LL LIVE LOAD REV'D REVISED D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 888.901.8008 www.base-4.com
GRID SUSPENDED FROM STRUCTURE
AFF ABOVE FINISHED FLOOR EQUIP EQUIPMENT L.P. LOW-POINT / LOW-PRESSURE RFI REQUEST FOR INFORMATION ARCHITECT:
DOOR MANEUVERING SPACE: LATCH SIDE APPROACH, PUSH SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 24'' X 42'' F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
E PUSH SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 24'' X 48''(WHEN DOOR HAS CLOSER) AFG ABOVE FINISHED GRADE EW/EF EACH WAY / EACH FACE LT LIGHT RH RIGHT HAND PAINTED
Ricardo J. Muniz-Guillet, AIA
AHU AIR HANDLING UNIT EWC ELECTRIC WATER COOLER LVR LOUVER RWL RAINWATER LEADER H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
DOOR MANEUVERING SPACE: LATCH SIDE APPROACH, PULL SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 24'' X 48'' CLG. GRID SUSPENDED FROM STRUCTURE A CEILING FINISH
2030 Habersham Trce
F PULL SIDE CLEAR FLOOR SPACE = DOOR WIDTH + 24'' X 54''(WHEN DOOR HAS CLOSER)
ALT ALTERNATE EWG END WALL GUARD RM ROOM
J PRIME AND PAINTED EXTERIOR GYPSUM BOARD 9'-6" CEILING HEIGHT Cumming, GA 30041
ALUM ALUMINUM EXIST EXISTING M R.O. ROUGH OPENING 954.812.6650
G AREA OF REFUGE: 30'' X 48'' CLEAR FLOOR SPACE ANOD ANODIZED EXP EXPANSION / EXPOSED MACH MACHINE / MACHINERY RT RESILIENT TILE [email protected]
AP ACCESS PANEL EXT EXTERIOR MAINT MAINTENANCE RTU ROOFTOP UNIT
H CLEAR FLOOR SPACE, LAVATORY CLEARANCE AND FRONT/SIDE APPROACH: 36'' X 48''
APPROX APPROXIMATE(LY) MAT'L MATERIAL
ELECTRICAL FIXTURE LEGEND
I WATER CLOSET CLEARANCE: 56'' x 60'' ARCH ARCHITECTURAL / ARCHITECT F MAX MAXIMUM S WIRING DEVICES
J ROLL IN SHOWER CLEARANCE: 30''x 60'' AUTO AUTOMATIC FA FIRE ALARM MECH MECHANICAL S SOUTH
NEMA 5-20R DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, UNO.
A/V AUDIO/ VISUAL FD FLOOR DRAIN MED MEDIUIM SC SOLID CORE XX
IG - ISOLATED GROUND
ACCESSIBLE ROUTE/WHEELCHAIR PASSAGE:
K 36'' WIDE AISLE x LENGTH OF ACCESSIBLE PIECE OF EQUIPMENT OR FURNITURE (48'' MIN.)
FDC FIRE DEPARTMENT CONNECTION MEMB MEMBRANE SCHED SCHEDULE GFCI - GROUND FAULT CIRCUIT INTERRUPTER
B FES FIRE EXIT SIGN MEP MECHANICAL/ELECTRICAL/PLUMBING SCWD SOLID CORE WOOD DOOR WP - WEATHER PROOF
AC - MOUNTED 4" ABOVE COUNTER
TURNING SPACE: 5'-0'' DIAMETER TURNING AREA(T-SHAPED SPACE ALSO ALLOWED PER ACCESSIBILITY B.C. BOTTOM OF CURB FE FIRE EXTINGUISHER MFR MANUFACTURER SECT SECTION
L REQUIREMENTS)
USB - USB OUTLET
BD BOARD FEC FIRE EXTINGUISHER CABINET MH MAN HOLE SF SQUARE FOOT / SQUARE FEET H - HORIZONTAL OUTLET
BIT BITUMINOUS FF FACTORY FINISH MIN MINIMUM SHELV SHELVING
NEMA 5-20R SWITCHED DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, UNO.
BLDG BUILDING FB FIBERGLASS MISC MISCELLANEAOUS SHT SHEET

SYMBOL LEGEND BLKG BLOCKING FH FIRE HYDRANT M METER S.I. SUPLLEMENTAL INSTRUCTIONS NEMA 5-20R DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, DEDICATED CIRCUIT, UNO.
BM BEAM FHC FIRE HOSE CABINET MM MILLIMETER SIM SIMILAR
N NEMA 5-20R DUPLEX RECEPTACLE FLOOR MOUNTED , UNO.
B.O.D. BOTTOM OF DECK FIN FINISH M.O. MASONRY OPENING SJ STEEL JOIST 11/30/2022 8:26:01
8:26:57 PM
BTM BOTTOM FL FLOOR MT METAL THRESHOLD S.O.G. SLAB ON GRADE NEMA 5-20R DUPLEX RECEPTACLE, CEILING MOUNTED, UNO.
NORTH ARROW WINDOW TAG 1t OWNER:
BRG BEARING FLUOR FLOURESCENT MTD MOUNTED SP SATIN POLYUREATHANE
NEMA 5-20R DOUBLE DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, DEDICATED CIRCUITS UNO.
B.U.R. BUILT-UP ROOFING F.O.C. FACE OF CONCRETE MTL METAL / METALLIC SPEC SPECIFCATION(S)
F.O.F. FACE OF FINISH MUL MULLION SQ SQUARE NEMA 5-20R DOUBLE DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, DEDICATED CIRCUITS UNO.
STOREFRONT TAG 1t C F.O.S. FACE OF STUD SQ/IN SQUARE INCH NEMA 5-20R DOUBLE DUPLEX RECEPTACLE FLOOR MOUNTED , UNO.
1  VIEW NAME 
DRAWING TITLE CAB CABINET FP FIREPROOFING / FIRE PROTECTION N SQ/YD SQUARE YARD
A-000 3/16" = 1'-0" REF: G-300 NEMA 5-20R DOUBLE DUPLEX RECEPTACLE CEILING MOUNTED , UNO.
CAT CATEGORY FR FRAME N NORTH S.S. STAINLESS STEEL / STANDING SEAM
CATV CABLE TELEVISION FRP FIBERGLASS REINFORCED PLASTIC NA NOT APPLICABLE STA STATION NEMA 5-20R DOUBLE DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, UNO. 10655 N.E. 4th Street, Suite 606 |
DOOR TAG 1t
CB CATCH BASIN FRT FIRE-RETARDANT TREATED NIC NOT IN CONTRACT STD STANDARD NEMA 5-20R SINGLE DUPLEX RECEPTACLE MOUNTED AT 18"AFF ON CENTER,UNO. Bellevue, WA 98004
ROOM NAME C.C. CENTER TO CENTER FT FOOT / FEET NO NUMBER STL STEEL
SPECIAL RECEPTACLE SEE PLAN NOTES FOR TYPE.
ROOM IDENTIFICATION 101 REVISION CLOUD 1 CCTV CLOSED CIRCUIT TELEVISION FTG FOOTING NOM NOMINAL STOR STORAGE [email protected]
TAG CEM CEMENT FUR FURRING NR NON-RATED STRUC STRUCTURAL J J JUNCTION BOX FOR ELEC. DEVICE INSTALLATION, PULL OR TAP BOX, CEILING, WALL OR FLOOR MOUNTED
150 SF P:(425) 598-8516
C.F.C.I. CONTRACTOR-FURNISHED / CONTRACTOR... FURN FURNITURE / FURNISHED NTS NOT TO SCALE SUSP SUSPENDED TV TELEVISION OUTLET MOUNTED BEHIND TV, UNO
FURNITURE TAG 1t PROJECT INFORMATION:
C.F.O.I. CONTRACTOR-FURNISHED / OWNER INSTALLED FUT FUTURE SV SATIN VARNISH
SIM CG CORNER GUARD FVC FIRE VALVE CABINET O SYM SYMMETRICAL TELEPHONE OUTLET MOUNTED AT 48" AFF, UNO
ENLARGED PLAN 1
CALLOUT A101 CI CAST IRON OA OVERALL / OUTSIDE AIR SYS SYSTEM DATA OUTLET MOUNTED AT 18" AFF, UNO
EQUIPMENT TAG 1t
CIP CAST-IN-PLACE G O.C. ON CENTER
COMBINATION DATA/PHONE OUTLET MOUNTED AT 18" AFF, UNO
CJ CONTROL JOINT / CONSTRUCTION JOINT GA GAUGE OD OUTSIDE DIAMETER T
HP
1t CL CENTERLINE GALV GALVANIZED OFF OFFICE T TEMPERED HOUSEPHONE OUTLET MOUNTED AT 48" AFF, UNO
FINISH TAG
CLG CEILING G.C. GENERAL CONTRACTOR O.F.C.I. OWNER-FURNISHED / CONTRACTOR INSTALLED T&B TOP AND BOTTOM
SIM TV 2 GANG FLOOR BOX WITH DUPLEX RECEPTACLE AND TV OUTLET.
BUILDING / WALL 1 CLOS CLOSET GEN'L GENERAL O.F.O.I. OWNER-FURNISHED / OWNER INSTALLED T&G TONGUE AND GROOVE MEDFORD, OR
SECTION REFERENCE A101 DIRECTION FOR CMU CONCRETE MASONRY UNIT GL GLASS / GLAZING O.H. OVERHEAD T.C. TOP OF CURB 2 GANG FLOOR BOX WITH DUPLEX RECEPTACLE AND COMMUNICATION OUTLET.
INSTALLATION
C.O. CLEANOUT GLAM GLUE-LAMINATED OPG OPENING TEL TELEPHONE
CR CARD READER MOUNTED AT 46" AFF, UNO
COL COLUMN GYP GYPSUM OPS OPPOSITE TEMP TEMPORARY Prototype Version 3.0
1 0 COMM COMMUNICATION(S) GYP.... GYPSUM BOARD ORD OVERFLOW ROOF DRAIN THERM THERMOSTAT CIRCUIT BREAKER August 2022
CONC CONCRETE TMP'D TERRAZZO
INTERIOR ELEVATION 1 A-101.1 1 GRID / COLUMN
$ 125V OR 277V AC SINGLE POLE 20 AMP SWITCH (ROCKER TYPE) MOUNTED AT 46" AFF ON CENTER, UNO. ISSUE
SYMBOL 0 CONST CONSTRUCTION H P T.O.C. TOP OF CONCRETE DELTA ISSUE DATE DESCRIPTION
BUBBLES NO.
CONT CONTINUOUS HB HOSE BIBB P/PNT PAINT T.O.S. TOP OF STEEL NON-FUSED DISCONNECT SWITCH
1
COORD COORDINATE HC HANDICAPPED PC PRECAST T.O.W. TOP OF WALL FUSED DISCONNECT SWITCH 1 A1 2022.11.30 ISSUED FOR
SCALE REFERENCE CORR CORRIDOR HCW HOLLOW CORE WOOD PERF PERFORATED TPH TOILET PAPER HOLDER PERMIT
1 CPT CARPET HD HEAVY DUTY PERIM PERIMETER TV TELEVISION GUEST ROOM DOORBELL PUSH-BUTTON MOUNTED @ 46" AFF
CT CERAMIC TILE HDWR HARDWARE PERP PERPENDICULAR TYP TYPICAL A GUEST ROOM DOOR ANNUNCIATOR MOUNTED @ 80" AFF
EXTERIOR ELEVATION A-101 CTR CENTER HM HOLLOW METAL PL PLATE / PROPERTY LINE
SYMBOL D GUEST ROOM DOORBELL DISCONNECT SWITCH MOUNTED @ 46" AFF
CU CUBIC HORIZ HORIZONTAL PLAM PLASTIC LAMINATE U
0' 2' 4' 8'
CW COLD WATER / CURTIAN WALL H.P. HIGHT POINT / HIGH-PRESSURE PLAS PLASTER UC UNDERCUT / UNDERCOUNTER WAP WIRELESS ACCESS POINT
C/W CURTAIN WALL HR HOUR PLBG PLUMBING UL UNDERWRITERS LABORATORIES, INC.
MATCHLINE / VIEW REFERENCE
H.S. HEAT-STRENGHTENED PLF POUNDS PER LINEAL FOOT UNO UNLESS NOTED OTHERWISE
SPOT ELEVATION 5'-5"
REFERENCE D HT HEIGHT PNL PANEL UR URINAL
- / ---

DBL DOUBLE HVAC HEATING, VENTILATING & AIR CON. POL POLISHED CEILING DIMENSION LEGEND
DEMO DEMOLISH / DEMOLITION HW HOT WATER PR PAIR / PROPOSAL REQUEST V
DEPT DEPARTMENT PREFAB PREFABRICATED VB VINYL BASE
- / ---

SPOT ELEVATION DH DOUBLE HUNG I PRELIM PRELIMINARY VCT VINYL COMPOSITION TILE
EX-6.1
REFERENCE DIA DIAMETER I.D. INSIDE DIAMETER PSF POUNDS PER SQUARE FOOT VERT VERTICAL
DIAG DIAGONAL IN INCH PSI POUNDS PER SQUARE INCH VEST VESTIBULE
CENTER FIXTURE IN SPACE ALIGN FIXTURES CENTER OVER
DIM DIMENSION INCL INCLUDED / INCLUDING P.T. PRESSURE-TREATED/ PAPER TOWEL V.I.F. VERIFY IN FIELD
DISP DISPENSER INFO INFORMATION PT POINT VOL VOLUME CENTER THE FIXTURE IN SPACE ALIGN FIXTURES ALONG CENTER THE FIXTURE IN SPACE
IDENTIFIED BY DIAGONAL LINE CENTERLINE SHOWN IDENTIFIED BY DIAGONAL LINE
DN DOWN INSUL INSULATION PTD PAINTED VTR VENT THROUGH ROOF
MATERIAL PATTERN LEGEND DP DAMP-PROOFING INT INTERIOR PTN PARTITION VWC VINYL WALLCOVERING
DS DOWNSPOUT PVC POLYVINYL CHLORIDE
DR DOOR J PVMT PAVEMENT W
REFLECTED CEILING PLAN LEGEND
DTL DETAIL JAN JANITOR PWD PLYWOOD W WEST FLUORESCENT LIGHT ACCESS PANEL LINEAR DIFFUSER
AP CURRENT ISSUE:
(2'-0"x4'-0") (1'-0"x1'-0" UNO)
DWG DRAWING JB JUNCTION BOX W/ WITH
FLUORESCENT LIGHT SUPPLY AIR DIFFUSER
GRADE GRAVEL CONCRETE BRICK WOOD PLYWOOD RIGID EXPANSION JC JANITOR'S CLOSET Q W/O WITHOUT SMOKE DETECTORS SD
(2'-0"x2'-0")
SPRINKLER HEADS
(FINISH) INSULATION MATERIAL E JST JOIST QT QUARRY TILE WB WALL BUMPER
DOWNLIGHT SPEAKERS S WALL MOUNT SPR. ISSUE FOR PERMIT
E EAST JT JOINT QTR QUARTER WB/H WALL BUMPER WITH HANDRAIL
SPRINKLER HEADS
EA EACH WC WATER CLOSET PENDANT LIGHT FIRE ALARM/HORN/STROBE F CEILING MOUNT
EIFS EXTERIOR INSULATION FINISH SYSTEM K R RADIUS / RISER WD WOOD CURRENT ISSUE DATE:
WALL WASH LIGHT CEILING LIGHT ACCESS PANEL
EJ EXPANSION JOINT KD KNOCK-DOWN RB RUBBER BASE WDW WINDOW (1'-0"x1'-0" UNO) AP 2022.11.30
EL ELEVATION K.O. KNOCK OUT RCP REFLECTED CEILING PLAN WH WATER HEATER STRIP LIGHTS
(RACK & HEADBOARDS) CEILING FAN OCCUPANCY SENSOR DRAWN BY:
STONE CONCRETE TILE PLASTER, METAL BATT WOOD SHIM OS
ELEC ELECTRICAL W.P. WATERPROOFING / WORK POINT
MASONRY SAND, GYP. INSULATION FRAMING, COMBINATION OF SMOKE PJ/RG
WALL MOUNT LIGHT CS DOOR BELL AUDIO
UNITS (CMU) BOARD, BLOCKING WT WEIGHT AND CO DETECTOR
VISUAL UNIT DB CHECKED BY:
PARTICLE RETURN/EXHAUST
BOARD WWF WELDED WIRE FABRIC EXIT LIGHT
GRILLE
LA/RB
PROJECT #:

B4-250-2101
SHEET NAME:

ABBREVIATIONS,
SYMBOLS, AND
LEGENDS

SHEET NUMBER:

G-004
0" 1"
304.4 Door Swing. Doors shall be permitted to swing into turning spaces.
CHAPTER 3: BUILDING BLOCKS 305 Clear Floor or Ground Space
306.3.4 Clearance Reduction. Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground,
301 General 305.1 General. Clear floor or ground space shall comply with 305. the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in
height.
301.1 Scope. The provisions of Chapter 3 shall apply where required by Chapter 2 or where referenced by a requirement in 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes
this document. in level are not permitted. 306.3.5 Width. Knee clearance shall be 30 inches (760 mm) wide minimum.

302 Floor or Ground Surfaces EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 2901 Clint Moore Rd, #114
302.1 General. Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302.
Boca Raton, FL 33496
305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum.
888.901.8008 www.base-4.com
EXCEPTIONS:
ARCHITECT:
1. Within animal containment areas, floor and ground surfaces shall not be required to be stable, firm, and slip
resistant.
2. Areas of sport activity shall not be required to comply with 302. 308.2 Forward Reach. Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
Advisory 302.1 General. A stable surface is one that remains unchanged by contaminants or applied force, so that 308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) Cumming, GA 30041
when the contaminant or force is removed, the surface returns to its original condition. A firm surface resists maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground.
deformation by either indentations or particles moving on its surface. A slip-resistant surface provides sufficient
954.812.6650
frictional counterforce to the forces exerted in walking to permit safe ambulation. [email protected]
302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or backing or no cushion or
pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be Figure 305.3 - Clear Floor or Ground Space
½ inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire
length of the exposed edge. Carpet edge trim shall comply with 303. 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee Figure 306.3 - Knee Clearance
and toe clearance complying with 306.
Advisory 302.2 Carpet. Carpets and permanently affixed mats can significantly increase the amount of force (roll 307 Protruding Objects
resistance) needed to propel a wheelchair over a surface. The firmer the carpeting and backing, the lower the roll 305.5 Position. Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel
resistance. A pile thickness up to ½ inch (13 mm) (measured to the backing, cushion, or pad) is allowed, although a approach to an element. 307.1 General. Protruding objects shall comply with 307.
lower pile provides easier wheelchair maneuvering. If a backing, cushion or pad is used, it must be firm. Preferably,
carpet pad should not be used because the soft padding increases roll resistance. 307.2 Protrusion Limits. Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm)
Figure 308.2.1 - Unobstructed Forward Reach
above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path.
308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall
EXCEPTION: Handrails shall be permitted to protrude 4½ inches (115 mm) maximum.
extend beneath the element for a distance not less than the required reach depth over the obstruction. The high
forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum.
Advisory 307.2 Protrusion Limits. When a cane is used and the element is in the detectable range, it gives a
Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum
person sufficient time to detect the element with the cane before there is body contact. Elements located on
Figure 302.2 - Carpet Pile Height and the reach depth shall be 25 inches (635 mm) maximum.
circulation paths, including operable elements, must comply with requirements for protruding objects. For example, 11/30/2022 8:26:01
8:26:59 PM
awnings and their supporting structures cannot reduce the minimum required vertical clearance. Similarly, casement
302.3 Openings. Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (13 mm) windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 OWNER:
diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10. Elongated openings shall be placed so that the mm).
long dimension is perpendicular to the dominant direction of travel.

Figure 305.5 - Position of Clear Floor or Ground Space


10655 N.E. 4th Street, Suite 606 |
305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an Bellevue, WA 98004
accessible route or adjoin another clear floor or ground space.

305.7 Maneuvering Clearance. Where a clear floor or ground space is located in an alcove or otherwise confined on all or [email protected]
Figure 308.2.2 - Obstructed High Forward Reach
part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1 and 305.7.2. P:(425) 598-8516
308.3 Side Reach. PROJECT INFORMATION:
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches
(610 mm).
308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side
reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be
15 inches (380 mm) minimum above the finish floor or ground.

Figure 307.2 - Limits of Protruding Objects EXCEPTIONS:


1. An obstruction shall be permitted between the clear floor or ground space and the element where
Figure 302.3 - Elongated Openings in Floor or Ground Surfaces 307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches the depth of the obstruction is 10 inches (255 mm) maximum.
(305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor or 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum
ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or measured from the surface of the vehicular way where fuel dispensers are installed on existing
303 Changes in Level pylons is greater than 12 inches (305 mm), the lowest edge of such sign or obstruction shall be 27 inches (685 mm) maximum curbs. MEDFORD, OR
or 80 inches (2030 mm) minimum above the finish floor or ground.
303.1 General. Where changes in level are permitted in floor or ground surfaces, they shall comply with 303.
EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3. Prototype Version 3.0
EXCEPTIONS:
1. Animal containment areas shall not be required to comply with 303. August 2022
2. Areas of sport activity shall not be required to comply with 303. Figure 305.7.1 - Maneuvering Clearance in an Alcove, Forward Approach
ISSUE
DELTA ISSUE DATE DESCRIPTION
303.2 Vertical. Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. 305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 NO.
inches (380 mm).
1 A1 2022.11.30 ISSUED FOR
PERMIT

Figure 303.2 - Vertical Change in Level

303.3 Beveled. Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (13 mm) high maximum shall be
beveled with a slope not steeper than 1:2.
Figure 308.3.1 - Unobstructed Side Reach
Advisory 303.3 Beveled. A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼
inch (6.4 mm) beveled. However, in no case may the combined change in level exceed ½ inch (13 mm). Changes in 308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a parallel approach to an element and
Figure 305.7.2 - Maneuvering Clearance in an Alcove, Parallel Approach
level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and
the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220
306 Knee and Toe Clearance
mm) maximum for a reach depth of 10 inches (255 mm) maximum. Where the reach depth exceeds 10 inches (255
Figure 307.3 - Post-Mounted Protruding Objects
mm), the high side reach shall be 46 inches (1170 mm) maximum for a reach depth of 24 inches (610 mm)
306.1 General. Where space beneath an element is included as part of clear floor or ground space or turning space, the maximum.
space shall comply with 306. Additional space shall not be prohibited beneath an element but shall not be considered as part 307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall
of the clear floor or ground space or turning space. be provided where the vertical clearance is less than 80 inches (2030 mm) high. The leading edge of such guardrail or barrier
EXCEPTIONS:
shall be located 27 inches (685 mm) maximum above the finish floor or ground.
1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm)
Advisory 306.1 General. Clearances are measured in relation to the usable clear floor space, not necessarily to the maximum above the finish floor.
Figure 303.3 Beveled Change in Level vertical support for an element. When determining clearance under an object for required turning or maneuvering EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish
2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum
space, care should be taken to ensure the space is clear of any obstructions. floor or ground.
303.4 Ramps. Changes in level greater than ½ inch (13 mm) high shall be ramped, and shall comply with 405 or 406. measured from the surface of the vehicular way where fuel dispensers are installed on existing
curbs.
306.2 Toe Clearance.
304 Turning Space
306.2.1 General. Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish
304.1 General. Turning space shall comply with 304. floor or ground shall be considered toe clearance and shall comply with 306.2.

304.2 Floor or Ground Surfaces. Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not 306.2.2 Maximum Depth. Toe clearance shall extend 25 inches (635 mm) maximum under an
permitted. element.

EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 306.2.3 Minimum Required Depth. Where toe clearance is required at an element as part of a clear floor space, the CURRENT ISSUE:
toe clearance shall extend 17 inches (430 mm) minimum under the element.
Advisory 304.2 Floor or Ground Surface Exception. As used in this section, the phrase “changes in level” refers to
surfaces with slopes and to surfaces with abrupt rise exceeding that permitted in Section 303.3. Such changes in 306.2.4 Additional Clearance. Space extending greater than 6 inches (150 mm) beyond the available knee
level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people
using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or
clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance. ISSUE FOR PERMIT
maneuver to use elements such as at doors, fixtures, and telephones. The exception permits slopes not steeper than 306.2.5 Width. Toe clearance shall be 30 inches (760 mm) wide minimum.
1:48. Figure 307.4 - Vertical Clearance.
CURRENT ISSUE DATE:
304.3 Size. Turning space shall comply with 304.3.1 or 304.3.2.
2022.11.30
304.3.1 Circular Space. The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space 307.5 Required Clear Width. Protruding objects shall not reduce the clear width required for accessible DRAWN BY:
Figure 308.3.2 - Obstructed High Side Reach
shall be permitted to include knee and toe clearance complying with 306. routes.
309 Operable Parts PJ/RG
304.3.2 T-Shaped Space. The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum 308 Reach Ranges
CHECKED BY:
with arms and base 36 inches (915 mm) wide minimum. Each arm of the T shall be clear of obstructions 12 inches
309.1 General. Operable parts shall comply with 309.
(305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum. The 308.1 General. Reach ranges shall comply with 308. LA/RB
space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided. PROJECT #:
one arm.
Advisory 308.1 General. The following table provides guidance on reach ranges for children according to age where
building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children. These
309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308. B4-250-2101
dimensions apply to either forward or side reaches. Accessible elements and operable parts designed for adult use SHEET NAME:
309.4 Operation. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of
or children over age 12 can be located outside these ranges but must be within the adult reach ranges required by
the wrist. The force required to activate operable parts shall be 5 pounds (22.2 N) maximum.
308.
Figure 306.2 - Toe Clearance Children's Reach Ranges
EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5
306.3 Knee Clearance. Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12
pounds (22.2 N) maximum ADA 2009
306.3.1 General. Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish High (maximum) 36 in (915 mm) 40 in (1015 mm) 44 in (1120 mm) ACCESSIBILITY
floor or ground shall be considered knee clearance and shall comply with 306.3.
Low (minimum) 20 in (510 mm) 18 in (455 mm) 16 in (405 mm) DETAILS
306.3.2 Maximum Depth. Knee clearance shall extend 25 inches (635 mm) maximum under an
element at 9 inches (230 mm) above the finish floor or ground.

306.3.3 Minimum Required Depth. Where knee clearance is required under an element as part of a clear floor
NOTE SHEET NUMBER:
space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor or INFORMATION PROVIDED ON THIS SHEET IS TAKEN FROM 2010 AMERICANS WITH DISABILITIES ACT. IT IS PROVIDED AS A GENERAL

G-010
ground, and 8 inches (205 mm) deep minimum at 27 inches (685 mm) above the finish floor or ground. REFERENCE ONLY AND DOES NOT REPRESENT A COMPLETE LISTING OF GUIDELINES NECESSARY TO MEET ACCESSIBILITY CODE
Figure 304.3.2 - T-Shaped Turning Space REQUIREMENTS. ADDITIONAL INFORMATION IS PROVIDED ON THE PLUMBING FIXTURE SCHEDULE, DRAWING DETAILS, AND NOTED
THROUGHOUT THE CONSTRUCTION DOCUMENTS.

0" 1"
404.2.4 Maneuvering Clearances. Minimum maneuvering clearances at doors and gates shall comply with 404.2.4. 404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors. Doorways less than 36
CHAPTER 4: ACCESSIBLE ROUTES Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side
clearance.
inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering
clearances complying with Table 404.2.4.2.

401 General EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond Table 404.2.4.2 Maneuvering Clearances at Doorways without Doors or Gates, Manual Sliding Doors, and Manual
the latch side of the door. Folding Doors
401.1 Scope. The provisions of Chapter 4 shall apply where required by Chapter 2 or where referenced by a requirement in
this document. 404.2.4.1 Swinging Doors and Gates. Swinging doors and gates shall have maneuvering clearances Minimum Maneuvering Clearance
complying with Table 404.2.4.1.
402 Accessible Routes 2901 Clint Moore Rd, #114
Parallel to Doorway (beyond
Table 404.2.4.1 Maneuvering Clearances at Manual Swinging Doors and Gates Approach Direction Perpendicular to Doorway
402.1 General. Accessible routes shall comply with 402.
stop/latch side unless noted) Boca Raton, FL 33496
Type of Use Minimum Maneuvering Clearance From Front 48 inches (1220 mm) 0 inches (0 mm)
888.901.8008 www.base-4.com
402.2 Components. Accessible routes shall consist of one or more of the following components: walking surfaces with a
Parallel to Doorway From side *1 42 inches (1065 mm) 0 inches (0 mm) ARCHITECT:
running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators, and platform lifts. All Perpendicular to
Approach Direction Door or Gate Side (beyond latch side From pocket/hinge side 42 inches (1065 mm) 22 inches (560 mm) *2
components of an accessible route shall comply with the applicable requirements of Chapter 4 Doorway
unless noted) Ricardo J. Muniz-Guillet, AIA
From stop/latch side 42 inches (1065 mm) 24 inches (610 mm)
Advisory 402.2 Components. Walking surfaces must have running slopes not steeper than 1:20, see 403.3. Other From front Pull 60 inches (1525 mm) 18 inches (455 mm) 2030 Habersham Trce
404.2.8 Closing Speed. Door and gate closing speed shall comply with 404.2.8.
components of accessible routes, such as ramps (405) and curb ramps (406), are permitted to be more steeply From front Push 48 inches (1220 mm) 0 inches (0 mm) *1 1. Doorway with no door only. 404.2.8.1 Door Closers and Gate Closers. Door closers and gate closers shall be adjusted so that from an
Cumming, GA 30041
sloped.
From hinge side Pull 60 inches (1525 mm) 36 inches (915 mm) 2. Beyond pocket/hinge side. open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 954.812.6650
403 Walking Surfaces From hinge side Pull 54 inches (1370 mm) 42 inches (1065 mm) 5 seconds minimum. [email protected]
404.2.8.2 Spring Hinges. Door and gate spring hinges shall be adjusted so that from the open position of 70
From hinge side Push 42 inches (1065 mm) *2 22 inches (560 mm) *3
degrees, the door or gate shall move to the closed position in 1.5 seconds minimum.
403.1 General. Walking surfaces that are a part of an accessible route shall comply with 403. From latch side Pull 48 inches (1220 mm) *4 24 inches (610 mm) 404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate
From latch side Push 42 inches (1065 mm) *4 24 inches (610 mm) administrative authority. The force for pushing or pulling open a door or gate other than fire doors shall be as follows:
403.2 Floor or Ground Surface. Floor or ground surfaces shall comply with 302.
1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum.
2. Sliding or folding doors: 5 pounds (22.2 N) maximum.
403.3 Slope. The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall 1. Add 12 inches (305 mm) if closer and latch are provided.
These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or
not be steeper than 1:48. 2. Add 6 inches (150 mm) if closer and latch are provided.
gate in a closed position.
3. Beyond hinge side.
4. Add 6 inches (150 mm) if closer is provided. Advisory 404.2.9 Door and Gate Opening Force. The maximum force pertains to the continuous
403.4 Changes in Level. Changes in level shall comply with 303.
application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the
door. It does not apply to the force required to retract bolts or to disengage other devices used to keep the
403.5 Clearances. Walking surfaces shall provide clearances complying with 403.5.
door in a closed position.
404.2.10 Door and Gate Surfaces. Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or
EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be
ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate.
decreased by work area equipment provided that the decrease is essential to the function of the work being
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as
performed.
the other. Cavities created by added kick plates shall be capped.
EXCEPTIONS:
403.5.1 Clear Width. Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36
1. Sliding doors shall not be required to comply with 404.2.10.
inches (915 mm) minimum.
2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge 11/30/2022 8:26:01
8:27:03 PM
tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch (255
EXCEPTION: The clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length OWNER:
mm) bottom smooth surface height requirement.
of 24 inches (610 mm) maximum provided that reduced width segments are separated by segments that are 3. Doors and gates that do not extend to within 10 inches (255 mm) of the finish floor or ground shall
48 inches (1220 mm) long minimum and 36 inches (915 mm) wide minimum.
not be required to comply with 404.2.10.
4. Existing doors and gates without smooth surfaces within 10 inches (255 mm) of the finish floor or
ground shall not be required to provide smooth surfaces complying with 404.2.10 provided that if
added kick plates are installed, cavities created by such kick plates are capped.
Figure 404.2.4.2 - Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors 404.2.11 Vision Lights. Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing
panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches
(1090 mm) maximum above the finish floor. 10655 N.E. 4th Street, Suite 606 |
404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided EXCEPTION: Vision lights with the lowest part more than 66 inches (1675 mm) from the finish floor or
when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches Bellevue, WA 98004
ground shall not be required to comply with 404.2.11.
(205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate.
404.3 Automatic and Power-Assisted Doors and Gates. Automatic doors and automatic gates shall comply with 404.3. [email protected]
Advisory 404.2.4.3 Recessed Doors and Gates. A door can be recessed due to wall thickness or Full-powered automatic doors shall comply with ANSI/BHMA A156.10 (incorporated by reference, see “Referenced
because of the placement of casework and other fixed elements adjacent to the doorway. This Standards” in Chapter 1). Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19 (1997 or 2002
P:(425) 598-8516
provision must be applied wherever doors are recessed. edition) (incorporated by reference, see “Referenced Standards” in Chapter 1).
Figure 403.5.1 - Clear Width of an Accessible Route PROJECT INFORMATION:
404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and
403.5.2 Clear Width at Turn. Where the accessible route makes a 180 degree turn around an element which is less
power-off mode. The minimum clear width for automatic door systems in a doorway shall be based on the clear
than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48 inches
opening provided by all leaves in the open position.
(1220 mm) minimum at the turn and 42 inches (1065 mm) minimum leaving the turn.
404.3.2 Maneuvering Clearance. Clearances at power-assisted doors and gates shall comply with 404.2.4.
Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall
EXCEPTION: Where the clear width at the turn is 60 inches (1525 mm) minimum compliance with 403.5.2 comply with 404.2.4.
shall not be required.
EXCEPTION: Where automatic doors and gates remain open in the power-off condition, compliance with
404.2.4 shall not be required.
404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with 404.2.5.
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6. MEDFORD, OR
404.3.5 Controls. Manually operated controls shall comply with 309. The clear floor space adjacent to the control
shall be located beyond the arc of the door swing.
404.3.6 Break Out Opening. Where doors and gates without standby power are a part of a means of egress, the
clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated Prototype Version 3.0
in emergency mode. August 2022
EXCEPTION: Where manual swinging doors and gates comply with 404.2 and serve the same means of
egress compliance with 404.3.6 shall not be required. ISSUE
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall DELTA ISSUE DATE DESCRIPTION
NO.
not be part of an accessible route.
1 A1 2022.11.30 ISSUED FOR
405 Ramps
PERMIT
405.1 General. Ramps on accessible routes shall comply with 405.
EXCEPTION: In assembly areas, aisle ramps adjacent to seating and not serving elements required to be on an
accessible route shall not be required to comply with 405.
405.2 Slope. Ramp runs shall have a running slope not steeper than 1:12.
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than
1:12 complying with Table 405.2 where such slopes are necessary due to space limitations.
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities

Figure 403.5.2 - Clear Width at Turn Slope *1 Maximum Rise


Figure 404.2.4.3 - Maneuvering Clearances at Recessed Doors and Gates
403.5.3 Passing Spaces. An accessible route with a clear width less than 60 inches (1525 mm) shall provide Steeper than 1:10 but not steeper than 1:8 3 inches (75 mm)
passing spaces at intervals of 200 feet (61 m) maximum. Passing spaces shall be either: a space 60 inches (1525 404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall Steeper than 1:12 but not steeper than 1:10 6 inches (150 mm)
mm) minimum by 60 inches (1525 mm) minimum; or, an intersection of two walking surfaces providing a T-shaped comply with 302. Changes in level are not permitted.
space complying with 304.3.2 where the base and arms of the T-shaped space extend 48 inches (1220 mm) 1. A slope steeper than 1:8 is prohibited.
minimum beyond the intersection. EXCEPTIONS:
1. Slopes not steeper than 1:48 shall be permitted. Advisory 405.2 Slope. To accommodate the widest range of users, provide ramps with the least possible running
403.6 Handrails. Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall 2. Changes in level at thresholds complying with 404.2.5 shall be permitted. slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance presents
comply with 505. a greater barrier than steps, e.g., people with heart disease or limited stamina.
404.2.5 Thresholds. Thresholds, if provided at doorways, shall be ½ inch (13 mm) high maximum. Raised 405.3 Cross Slope. Cross slope of ramp runs shall not be steeper than 1:48.
Advisory 403.6 Handrails. Handrails provided in elevator cabs and platform lifts are not required to comply with the thresholds and changes in level at doorways shall comply with 302 and 303. Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel. Cross
requirements for handrails on walking surfaces. slope is measured the same way as slope is measured (i.e., the rise over the run).
EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on 405.4 Floor or Ground Surfaces. Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than
404 Doors, Doorways, and Gates each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5. the running slope and cross slope are not permitted on ramp runs.
405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall
404.1 General. Doors, doorways, and gates that are part of an accessible route shall comply with 404. 404.2.6 Doors in Series and Gates in Series. The distance between two hinged or pivoted doors in series and be 36 inches (915 mm) minimum.
gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space. EXCEPTION: Within employee work areas, the required clear width of ramps that are a part of common use
EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel shall not be required circulation paths shall be permitted to be decreased by work area equipment provided that the decrease is essential
to comply with 404.2.7, 404.2.8, 404.2.9, 404.3.2 and 404.3.4 through 404.3.7. to the function of the work being performed.
CURRENT ISSUE:
405.6 Rise. The rise for any ramp run shall be 30 inches (760 mm) maximum.
Advisory 404.1 General Exception. Security personnel must have sole control of doors that are eligible for the 405.7 Landings. Ramps shall have landings at the top and the bottom of each ramp run. Landings shall comply with 405.7.
Exception at 404.1. It would not be acceptable for security personnel to operate the doors for people with disabilities Advisory 405.7 Landings. Ramps that do not have level landings at changes in direction can create a compound
while allowing others to have independent access. slope that will not meet the requirements of this document. Circular or curved ramps continually change direction. ISSUE FOR PERMIT
Curvilinear ramps with small radii also can create compound cross slopes and cannot, by their nature, meet the
404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user requirements for accessible routes. A level landing is needed at the accessible door to permit maneuvering and
passage shall comply with 404.2. simultaneously door operation.
CURRENT ISSUE DATE:
404.2.1 Revolving Doors, Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part
of an accessible route. 2022.11.30
DRAWN BY:
404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply
with 404.2.3 and 404.2.4. PJ/RG
CHECKED BY:
404.2.3 Clear Width. Door openings shall provide a clear width of 32 inches (815 mm) minimum. Clear openings of
doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 LA/RB
degrees. Openings more than 24 inches (610 mm) deep shall provide a clear opening of 36 inches (915 mm) Figure 404.2.6 - Doors in Series and Gates in Series
minimum. There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above PROJECT #:
the finish floor or ground. Projections into the clear opening width between 34 inches (865 mm) and 80 inches (2030 404.2.7 Door and Gate Hardware. Handles, pulls, latches, locks, and other operable parts on doors and gates shall
mm) above the finish floor or ground shall not exceed 4 inches (100 mm). comply with 309.4. Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 B4-250-2101
EXCEPTIONS: mm) maximum above the finish floor or ground. Where sliding doors are in the fully open position, operating SHEET NAME:
1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be hardware shall be exposed and usable from both sides. Figure 405.7 - Ramp Landings
permitted for the latch side stop.
2. Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the EXCEPTIONS:
finish floor or ground. 1. Existing locks shall be permitted in any location at existing glazed doors without stiles, existing
overhead rolling doors or grilles, and similar existing doors or grilles that are designed with locks NOTE ADA 2009
2.
that are activated only at the top or bottom rail.
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to INFORMATION PROVIDED ON THIS SHEET IS TAKEN FROM 2010 AMERICANS WITH DISABILITIES ACT. IT IS PROVIDED AS A GENERAL
REFERENCE ONLY AND DOES NOT REPRESENT A COMPLETE LISTING OF GUIDELINES NECESSARY TO MEET ACCESSIBILITY CODE
ACCESSIBILITY
have operable parts of the release of latch on self-latching devices at 54 inches (1370 mm)
maximum above the finish floor or ground provided the self-latching devices are not also self-locking
devices and operated by means of a key, electronic opener, or integral combination lock.
REQUIREMENTS. ADDITIONAL INFORMATION IS PROVIDED ON THE PLUMBING FIXTURE SCHEDULE, DRAWING DETAILS, AND NOTED
THROUGHOUT THE CONSTRUCTION DOCUMENTS.
DETAILS
Advisory 404.2.7 Door and Gate Hardware. Door hardware that can be operated with a closed fist or a
loose grip accommodates the greatest range of users. Hardware that requires simultaneous hand and finger SHEET NUMBER:
movements require greater dexterity and coordination, and is not recommended.

Figure 404.2.3 - Clear Width of Doorways


Figure 404.2.4.1 - Maneuvering Clearances at Manual Swinging Doors and Gates
G-011
0" 1"
405.7.1 Slope. Landings shall comply with 302. Changes in level are not permitted.

EXCEPTION: Slopes not steeper than 1:48 shall be permitted.

405.7.2 Width. The landing clear width shall be at least as wide as the widest ramp run leading to the landing.

405.7.3 Length. The landing clear length shall be 60 inches (1525 mm) long minimum.

405.7.4 Change in Direction. Ramps that change direction between runs at landings shall have a clear landing 60
inches (1525 mm) minimum by 60 inches (1525 mm) minimum. 2901 Clint Moore Rd, #114
Boca Raton, FL 33496
405.7.5 Doorways. Where doorways are located adjacent to a ramp landing, maneuvering clearances required by
404.2.4 and 404.3.2 shall be permitted to overlap the required landing area.
888.901.8008 www.base-4.com
ARCHITECT:
405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails complying with 505.
Table 407.4.1 Elevator Car Dimensions Ricardo J. Muniz-Guillet, AIA
EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use
circulation paths are designed to permit the installation of handrails complying with 505. Ramps not subject to the Minimum Dimensions 2030 Habersham Trce
exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are Figure 407.2.2.2 - Visible Hall Signals Cumming, GA 30041
installed. Inside Car, Back Inside Car, Back 954.812.6650
Inside Car, Side
407.2.2.3 Audible Signals. Audible signals shall sound once for the up direction and twice for the down Door Location Door Clear Width Wall to Front Wall to Inside
Figure 406.6 - Diagonal or Corner Type Curb Ramps direction, or shall have verbal annunciators that indicate the direction of elevator car travel. Audible signals
to Side
Return Face of Door [email protected]
405.9 Edge Protection. Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and
at each side of ramp landings. shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz
406.7 Islands. Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides. Each minimum and 3000 Hz maximum. The audible signal and verbal annunciator shall be 10 dB minimum above 42 inches 80 inches 51 inches 54 inches
curb ramp shall have a level area 48 inches (1220 mm) long minimum by 36 inches (915 mm) wide minimum at the top of the Centered
EXCEPTIONS: ambient, but shall not exceed 80 dB, measured at the hall call button. (1065 mm) (2030 mm) (1295 mm) (1370 mm)
curb ramp in the part of the island intersected by the crossings. Each 48 inch (1220 mm) minimum by 36 inch (915 mm)
1. Edge protection shall not be required on ramps that are not required to have handrails and have sides Side 36 inches 68 inches 51 inches 54 inches
minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the EXCEPTIONS:
complying with 406.3. (off-centered) (915 mm) *1 (1725 mm) (1295 mm) (1370 mm)
curb ramp it serves. The 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum areas and the accessible route shall be 1. Destination-oriented elevators shall not be required to comply with 407.2.2.3 provided that
2. Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or
permitted to overlap. the audible tone and verbal announcement is the same as those given at the call button or
stairway. 36 inches 54 inches 80 inches 80 inches
call button keypad. Any
3. Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 (915 mm) *1 (1370 mm) (2030 mm) (2030 mm)
mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area specified in 405.7. 2. Existing elevators shall not be required to comply with the requirements for frequency and
dB range of audible signals. 36 inches 60 inches 60 inches 60 inches
Any
(915 mm) *1 (1525 mm) *2 (1525 mm) *2 (1525 mm) *2
405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches
(305 mm) minimum beyond the inside face of a handrail complying with 505. 407.2.2.4 Differentiation. Each destination-oriented elevator in a bank of elevators shall have audible and
visible means for differentiation.
1. A tolerance of minus 5/8 inch (16 mm) is permitted.
Advisory 405.9.1 Extended Floor or Ground Surface. The extended surface prevents wheelchair casters and
407.2.3 Hoistway Signs. Signs at elevator hoistways shall comply with 407.2.3. 2. Other car configurations that provide a turning space complying with 304 with the door closed shall be
crutch tips from slipping off the ramp surface.
permited.
407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on
both jambs of elevator hoistway entrances. Floor designations shall be provided in both tactile characters
and braille. Tactile characters shall be 2 inches (51 mm) high minimum. A tactile star shall be provided on
11/30/2022 8:26:01
8:27:06 PM
both jambs at the main entry level. OWNER:

Figure 405.9.1 - Extended Floor or Ground Surface Edge Protection

405.9.2 Curb or Barrier. A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, 10655 N.E. 4th Street, Suite 606 |
where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface.
Bellevue, WA 98004
Figure 406.7 - Islands in Crossings
[email protected]
407 Elevators
P:(425) 598-8516
407.1 General. Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see “Referenced PROJECT INFORMATION:
Standards” in Chapter 1). They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be
automatic. Figure 407.2.3.1 - Floor Designations on Jambs of Elevator Hoistway Entrances
Advisory 407.1 General. The ADA and other Federal civil rights laws require that accessible features be maintained 407.2.3.2 Car Designations. Destination-oriented elevators shall provide tactile car identification complying
in working order so that they are accessible to and usable by those people they are intended to benefit. Building with 703.2 on both jambs of the hoistway immediately below the floor designation. Car designations shall be
owners should note that the ASME Safety Code for Elevators and Escalators requires routine maintenance and provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum.
Figure 405.9.2 - Curb or Barrier Edge Protection
inspections. Isolated or temporary interruptions in service due to maintenance or repairs may be unavoidable;
however, failure to take prompt action to effect repairs could constitute a violation of Federal laws and these
405.10 Wet Conditions. Landings subject to wet conditions shall be designed to prevent the accumulation of water. requirements.
406 Curb Ramps 407.2 Elevator Landing Requirements. Elevator landings shall comply with 407.2. MEDFORD, OR
406.1 General. Curb ramps on accessible routes shall comply with 406, 405.2 through 405.5, and 405.10. 407.2.1 Call Controls. Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and
309.4. Call buttons shall be raised or flush.
406.2 Counter Slope. Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not Prototype Version 3.0
be steeper than 1:20. The adjacent surfaces at transitions at curb ramps to walks, gutters, and streets shall be at the same
level.
EXCEPTION: Existing elevators shall be permitted to have recessed call buttons. August 2022
407.2.1.1 Height. Call buttons and keypads shall be located within one of the reach ranges specified in 308, ISSUE
measured to the centerline of the highest operable part. DELTA ISSUE DATE DESCRIPTION
NO.

EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54
1 A1 2022.11.30 ISSUED FOR
inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest
PERMIT
operable part. Figure 407.2.3.2 - Car Designations on Jambs of Destination-Oriented Elevator Hoistway Entrances

407.2.1.2 Size. Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension. 407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3.

EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2. 407.3.1 Type. Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited.
Figure 406.2 - Counter Slope of Surfaces Adjacent to Curb Ramps
407.2.1.3 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided 407.3.2 Operation. Elevator hoistway and car doors shall open and close automatically. EXCEPTION: Existing
406.3 Sides of Curb Ramps. Where provided, curb ramp flares shall not be steeper than 1:10.
at call controls. manually operated hoistway swing doors shall be permitted provided that they comply with 404.2.3 and 404.2.9. Car
door closing shall not be initiated until the hoistway door is closed.
Advisory 407.2.1.3 Clear Floor or Ground Space. The clear floor or ground space required at
elevator call buttons must remain free of obstructions including ashtrays, plants, and other 407.3.3 Reopening Device. Elevator doors shall be provided with a reopening device complying with 407.3.3 that
decorative elements that prevent wheelchair users and others from reaching the call buttons. The shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or
height of the clear floor or ground space is considered to be a volume from the floor to 80 inches person.
(2030 mm) above the floor. Recessed ashtrays should not be placed near elevator call buttons so
that persons who are blind or visually impaired do not inadvertently contact them or their contents EXCEPTION: Existing elevators with manually operated doors shall not be required to comply with 407.3.3.
as they reach for the call buttons.
407.3.3.1 Height. The device shall be activated by sensing an obstruction passing through the opening at 5
407.2.1.4 Location. The call button that designates the up direction shall be located above the call button inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
that designates the down direction. Figure 407.4.1 Elevator Car Dimensions
407.3.3.2 Contact. The device shall not require physical contact to be activated, although contact is
EXCEPTION: Destination-oriented elevators shall not be required to comply with 407.2.1.4. permitted to occur before the door reverses. 407.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303.
Figure 406.3 Sides of Curb Ramps
Advisory 407.2.1.4 Location Exception. A destination-oriented elevator system provides lobby 407.3.3.3 Duration. Door reopening devices shall remain effective for 20 seconds minimum. 407.4.3 Platform to Hoistway Clearance. The clearance between the car platform sill and the edge of any hoistway
controls enabling passengers to select floor stops, lobby indicators designating which elevator to landing shall be 1¼ inch (32 mm) maximum.
406.4 Landings. Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm)
use, and a car indicator designating the floors at which the car will stop. Responding cars are 407.3.4 Door and Signal Timing. The minimum acceptable time from notification that a car is answering a call or
minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing.
programmed for maximum efficiency by reducing the number of stops any passenger experiences. notification of the car assigned at the means for the entry of destination information until the doors of that car start to 407.4.4 Leveling. Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the
close shall be calculated from the following equation: car at floor landings within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided
407.2.1.5 Signals. Call buttons shall have visible signals to indicate when each call is registered and when
and shall not be steeper than 1:12.
each call is answered. T = D/(1.5 ft/s) or T = D/(455 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the 407.4.5 Illumination. The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5
foot candles (54 lux) minimum. CURRENT ISSUE:
distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1525 mm) directly in front of the
EXCEPTIONS: farthest call button controlling that car to the centerline of its hoistway door.
1. Destination-oriented elevators shall not be required to comply with 407.2.1.5 provided that 407.4.6 Elevator Car Controls. Where provided, elevator car controls shall comply with 407.4.6 and 309.4.
visible and audible signals complying with 407.2.2 indicating which elevator car to enter are
provided.
EXCEPTIONS:
1. For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.6 is provided,
ISSUE FOR PERMIT
2. Existing elevators shall not be required to comply with 407.2.1.5. 60 inches (1525 mm) directly in front of the farthest hall call button and the audible signal is existing car operating panels shall not be required to comply with 407.4.6.
sounded.
407.2.1.6 Keypads. Where keypads are provided, keypads shall be in a standard telephone keypad 2. Destination-oriented elevators shall not be required to comply with 407.3.4. 407.4.6.1 Location. Controls shall be located within one of the reach ranges specified in 308. CURRENT ISSUE DATE:
arrangement and shall comply with 407.4.7.2. EXCEPTIONS:
407.3.5 Door Delay. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum. 1. Where the elevator panel serves more than 16 openings and a parallel approach is 2022.11.30
407.2.2 Hall Signals. Hall signals, including in-car signals, shall comply with 407.2.2. provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) DRAWN BY:
407.3.6 Width. The width of elevator doors shall comply with Table 407.4.1 maximum above the finish floor.
407.2.2.1 Visible and Audible Signals. A visible and audible signal shall be provided at each hoistway 2. In existing elevators, car control buttons with floor designations shall be permitted to be PJ/RG
entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted. located 54 inches (1370 mm) maximum above the finish floor where a parallel approach is
provided, they shall be visible from the floor area adjacent to the hall call buttons. provided. CHECKED BY:
Figure 406.4 407.4 Elevator Car Requirements. Elevator cars shall comply with 407.4. LA/RB
Landings at the Top of Curb Ramps
EXCEPTIONS: 407.4.6.2 Buttons. Car control buttons with floor designations shall comply with 407.4.6.2 and shall be
1. Visible and audible signals shall not be required at each destination- oriented elevator 407.4.1 Car Dimensions. Inside dimensions of elevator cars and clear width of elevator doors shall comply with raised or flush. PROJECT #:
where a visible and audible signal complying with 407.2.2 is provided indicating the elevator Table 407.4.1. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed.
406.5 Location. Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular B4-250-2101
car designation information.
traffic lanes, parking spaces, or parking access aisles. Curb ramps at marked crossings shall be wholly contained within the
2. In existing elevators, a signal indicating the direction of car travel shall not be required. EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum 407.4.6.2.1 Size. Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. SHEET NAME:
markings, excluding any flared sides.
and also provide an inside clear depth 54 inches (1370 mm) minimum and a clear width 36 inches (915 mm)
407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above minimum shall be permitted. 407.4.6.2.2 Arrangement. Buttons shall be arranged with numbers in ascending order. When two or
406.6 Diagonal Curb Ramps. Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have
the finish floor or ground. The visible signal elements shall be 2-½ inches (64 mm) minimum measured along more columns of buttons are provided they shall read from left to right.
the edges parallel to the direction of pedestrian flow. The bottom of
diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway.
Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1220 mm) minimum clear space within the
the vertical centerline of the element. Signals shall be visible from the floor area adjacent to the hall call
button. 407.4.6.3 Keypads. Car control keypads shall be in a standard telephone keypad arrangement and shall ADA 2009
comply with 407.4.7.2.
markings. Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on
each side of the curb ramp and within the marked crossing.
EXCEPTIONS:
1. Destination-oriented elevators shall be permitted to have signals visible from the floor area
ACCESSIBILITY
407.4.6.4 Emergency Controls. Emergency controls shall comply with 407.4.6.4.
Figure 406.6
adjacent to the hoistway entrance.
Existing elevators shall not be required to comply with 407.2.2.2. 407.4.6.4.1 Height. Emergency control buttons shall have their centerlines 35 inches (890 mm)
DETAILS
Diagonal or Corner Type Curb Ramps
minimum above the finish floor.
406.7 Islands. Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides. Each
curb ramp shall have a level area 48 inches (1220 mm) long minimum by 36 inches (915 mm) wide minimum at the top of the 407.4.6.4.2 Location. Emergency controls, including the emergency alarm, shall be grouped at the SHEET NUMBER:
curb ramp in the part of the island intersected by the crossings. Each 48 inch (1220 mm) minimum by 36 inch (915 mm) NOTE bottom of the panel.
minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the
curb ramp it serves. The 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum areas and the accessible route shall be
permitted to overlap.
INFORMATION PROVIDED ON THIS SHEET IS TAKEN FROM 2010 AMERICANS WITH DISABILITIES ACT. IT IS PROVIDED AS A GENERAL
REFERENCE ONLY AND DOES NOT REPRESENT A COMPLETE LISTING OF GUIDELINES NECESSARY TO MEET ACCESSIBILITY CODE
REQUIREMENTS. ADDITIONAL INFORMATION IS PROVIDED ON THE PLUMBING FIXTURE SCHEDULE, DRAWING DETAILS, AND NOTED
THROUGHOUT THE CONSTRUCTION DOCUMENTS.
G-012
0" 1"
407.4.7 Designations and Indicators of Car Controls. Designations and indicators of car controls shall comply with 410 Platform Lifts
407.4.7.
410.1 General. Platform lifts shall comply with ASME A18.1 (1999 edition or 2003 edition) (incorporated by reference, see
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, “Referenced Standards” in Chapter 1). Platform lifts shall not be attendant-operated and shall provide unassisted entry and
existing car operating panels shall not be required to comply with 407.4.7. exit from the lift.

407.4.7.1 Buttons. Car control buttons shall comply with 407.4.7.1. Advisory 410.1 General. Inclined stairway chairlifts and inclined and vertical platform lifts are available for short-
distance vertical transportation. Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care
407.4.7.1.1 Type. Control buttons shall be identified by tactile characters complying with 703.2. should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs and people
standing. If a lift does not provide 80 inch (2030 mm) vertical clearance, it cannot be considered part of an accessible 2901 Clint Moore Rd, #114
407.4.7.1.2 Location. Raised character and braille designations shall be placed immediately to the route in new construction. Boca Raton, FL 33496
left of the control button to which the designations apply. The ADA and other Federal civil rights laws require that accessible features be maintained in working order so that
they are accessible to and usable by those people they are intended to benefit. Building owners are reminded that the 888.901.8008 www.base-4.com
EXCEPTION: Where space on an existing car operating panel precludes tactile markings ASME A18 Safety Standard for Platform Lifts and Stairway Chairlifts requires routine maintenance and inspections. ARCHITECT:
to the left of the controls, markings shall be placed as near to the control as possible. Isolated or temporary interruptions in service due to maintenance or repairs may be unavoidable; however, failure to
take prompt action to effect repairs could constitute a violation of Federal laws and these requirements.
Ricardo J. Muniz-Guillet, AIA
407.4.7.1.3 Symbols. The control button for the emergency stop, alarm, door open, door close,
main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3. 410.2 Floor Surfaces. Floor surfaces in platform lifts shall comply with 302 and 303. 2030 Habersham Trce
Cumming, GA 30041
Table 407.4.7.1.3 Elevator Control Button Identification 410.3 Clear Floor Space. Clear floor space in platform lifts shall comply with 305. 954.812.6650
410.4 Platform to Runway Clearance. The clearance between the platform sill and the edge of any runway landing shall be
[email protected]
Control Button Tactile Symbol Braille Message
1¼ inch (32 mm) maximum.

Emergency Stop 410.5 Operable Parts. Controls for platform lifts shall comply with 309.
“ST”OP Three cells
410.6 Doors and Gates. Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors
shall remain open for 20 seconds minimum. End doors and gates shall provide a clear width 32 inches (815 mm) minimum.
Alarm Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum.
AL“AR”M Four cells
EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be
permitted to have self-closing manual doors or gates.
Door Open
OP“EN” Three cells

Door Close
CLOSE Five cells

11/30/2022 8:26:01
8:27:08 PM
Main Entry Floor
MA“IN” Three cells OWNER:
Figure 408.4.1 - Limited-Use/Limited-Application (LULA) Elevator Car Dimensions
Phone
PH“ONE” Four cells 408.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303.

408.4.3 Platform to Hoistway Clearance. The platform to hoistway clearance shall comply with 407.4.3.

407.4.7.1.4 Visible Indicators. Buttons with floor designations shall be provided with visible 408.4.4 Leveling. Elevator car leveling shall comply with 407.4.4.
indicators to show that a call has been registered. The visible indication shall extinguish when the
car arrives at the designated floor. 408.4.5 Illumination. Elevator car illumination shall comply with 407.4.5.
10655 N.E. 4th Street, Suite 606 |
Bellevue, WA 98004
407.4.7.2 Keypads. Keypads shall be identified by characters complying with 703.5 and shall be centered on 408.4.6 Car Controls. Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side
the corresponding keypad button. The number five key shall have a single raised dot. The dot shall be 0.118 wall.
inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 703.3.1. [email protected]
408.4.7 Designations and Indicators of Car Controls. Designations and indicators of car controls shall comply with P:(425) 598-8516
407.4.8 Car Position Indicators. Audible and visible car position indicators shall be provided in elevator cars. 407.4.7.
PROJECT INFORMATION:
407.4.8.1 Visible Indicators. Visible indicators shall comply with 407.4.8.1. 408.4.8 Emergency Communications. Car emergency signaling devices complying with 407.4.9 shall be provided. Figure 410.6 - Platform Lift Doors and Gates

407.4.8.1.1 Size. Characters shall be ½ inch (13 mm) high minimum. 409 Private Residence Elevators

407.4.8.1.2 Location. Indicators shall be located above the car control panel or above the door. 409.1 General. Private residence elevators that are provided within a residential dwelling unit required to provide mobility
features complying with 809.2 through 809.4 shall comply with 409 and with ASME A17.1 (incorporated by reference, see
407.4.8.1.3 Floor Arrival. As the car passes a floor and when a car stops at a floor served by the “Referenced Standards” in Chapter 1). They shall be passenger elevators as classified by ASME A17.1. Elevator operation
elevator, the corresponding character shall illuminate. shall be automatic.

EXCEPTION: Destination-oriented elevators shall not be required to comply with 409.2 Call Buttons. Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309.
407.4.8.1.3 provided that the visible indicators extinguish when the call has been answered.
MEDFORD, OR
409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404. EXCEPTION: Doors shall
407.4.8.1.4 Destination Indicator. In destination-oriented elevators, a display shall be provided in not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of
the car with visible indicators to show car destinations. swinging doors. Prototype Version 3.0
407.4.8.2 Audible Indicators. Audible indicators shall comply with 407.4.8.2. 409.3.1 Power Operation. Elevator car and hoistway doors and gates shall be power operated and shall comply with
August 2022
ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1).
407.4.8.2.1 Signal Type. The signal shall be an automatic verbal annunciator which announces the Power operated doors and gates shall remain open for 20 seconds minimum when activated. ISSUE
DELTA ISSUE DATE DESCRIPTION
floor at which the car is about to stop. NO.
EXCEPTION: In elevator cars with more than one opening, hoistway doors and gates shall be permitted to
EXCEPTION: For elevators other than destination-oriented elevators that have a rated be of the manual-open, self-close type. 1 A1 2022.11.30 ISSUED FOR
speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of PERMIT
1500 Hz maximum which sounds as the car passes or is about to stop at a floor served by 409.3.2 Location. Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required
the elevator shall be permitted. by 409.4.1.

407.4.8.2.2 Signal Level. The verbal annunciator shall be 10 dB minimum above ambient, but shall 409.4 Elevator Cars. Private residence elevator cars shall comply with 409.4.
not exceed 80 dB, measured at the annunciator.
409.4.1 Inside Dimensions of Elevator Cars. Elevator cars shall provide a clear floor space of 36 inches (915 mm)
407.4.8.2.3 Frequency. The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 minimum by 48 inches (1220 mm) minimum and shall comply with 305.
Hz maximum.
409.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303.
407.4.9 Emergency Communication. Emergency two-way communication systems shall comply with 308. Tactile
symbols and characters shall be provided adjacent to the device and shall comply with 703.2. 409.4.3 Platform to Hoistway Clearance. The clearance between the car platform and the edge of any landing sill
shall be 1½ inch (38 mm) maximum.
408 Limited-Use/Limited-Application Elevators
409.4.4 Leveling. Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under
408.1 General. Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by rated loading to zero loading conditions.
reference, see “Referenced Standards” in Chapter 1). They shall be passenger elevators as classified by ASME A17.1.
Elevator operation shall be automatic. 409.4.5 Illumination Levels. Elevator car illumination shall comply with 407.4.5.

408.2 Elevator Landings. Landings serving limited-use/limited-application elevators shall comply with 408.2. 409.4.6 Car Controls. Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or
flush.
408.2.1 Call Buttons. Elevator call buttons and keypads shall comply with 407.2.1.
409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
408.2.2 Hall Signals. Hall signals shall comply with 407.2.2.
409.4.6.2 Location. Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent
408.2.3 Hoistway Signs. Signs at elevator hoistways shall comply with 407.2.3.1. wall.

408.3 Elevator Doors. Elevator hoistway doors shall comply with 408.3.

408.3.1 Sliding Doors. Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1. CURRENT ISSUE:
408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404,
407.3.2 and 408.3.2.
ISSUE FOR PERMIT
408.3.2.1 Power Operation. Swinging doors shall be power-operated and shall comply with ANSI/BHMA
A156.19 (1997 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1).

408.3.2.2 Duration. Power-operated swinging doors shall remain open for 20 seconds minimum when CURRENT ISSUE DATE:
activated.
2022.11.30
408.4 Elevator Cars. Elevator cars shall comply with 408.4. DRAWN BY:

408.4.1 Car Dimensions and Doors. Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a PJ/RG
clear depth 54 inches (1370 mm) minimum. Car doors shall be positioned at the narrow ends of cars and shall CHECKED BY:
provide 32 inches (815 mm) minimum clear width.
EXCEPTIONS: LA/RB
1. Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear
Figure 409.4.6.2 - Location of Private Residence Elevator Control Panel PROJECT #:
depth 51 inches (1295 mm) minimum provided that car doors provide a clear opening 36 inches
(915 mm) wide minimum. B4-250-2101
2. Existing elevator cars shall be permitted to provide a clear width 36 inches (915 mm) minimum, 409.4.7 Emergency Communications. Emergency two-way communication systems shall comply with 409.4.7.
clear depth 54 inches (1370 mm) minimum, and a net clear platform area 15 square feet (1.4 m2) SHEET NAME:
minimum. 409.4.7.1 Type. A telephone and emergency signal device shall be provided in the car.

409.4.7.2 Operable Parts. The telephone and emergency signaling device shall comply with
309.3 and 309.4. ADA 2009
409.4.7.3 Compartment. If the telephone or device is in a closed compartment, the compartment door
hardware shall comply with 309.
ACCESSIBILITY
409.4.7.4 Cord. The telephone cord shall be 29 inches (735 mm) long minimum. DETAILS
NOTE SHEET NUMBER:
INFORMATION PROVIDED ON THIS SHEET IS TAKEN FROM 2010 AMERICANS WITH DISABILITIES ACT. IT IS PROVIDED AS A GENERAL
REFERENCE ONLY AND DOES NOT REPRESENT A COMPLETE LISTING OF GUIDELINES NECESSARY TO MEET ACCESSIBILITY CODE
REQUIREMENTS. ADDITIONAL INFORMATION IS PROVIDED ON THE PLUMBING FIXTURE SCHEDULE, DRAWING DETAILS, AND NOTED
THROUGHOUT THE CONSTRUCTION DOCUMENTS.
G-013
0" 1"
CHAPTER 5: GENERAL SITE AND
BUILDING ELEMENTS
501 General

501.1 Scope. The provisions of Chapter 5 shall apply where required by Chapter 2 or where referenced by a requirement in
this document. Figure 505.6 - Horizontal Projections Below Gripping Surface 2901 Clint Moore Rd, #114
Boca Raton, FL 33496
502 Parking Spaces 888.901.8008 www.base-4.com
505.7 Cross Section. Handrail gripping surfaces shall have a cross section complying with 505.7.1 or 505.7.2.
502.1 General. Car and van parking spaces shall comply with 502. Where parking spaces are marked with lines, width ARCHITECT:
measurements of parking spaces and access aisles shall be made from the centerline of the markings. 505.7.1 Circular Cross Section. Handrail gripping surfaces with a circular cross section shall have an outside
Figure 503.3 - Passenger Loading Zone Access Aisle
diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum. Ricardo J. Muniz-Guillet, AIA
EXCEPTION: Where parking spaces or access aisles are not adjacent to another parking space or access aisle, 503.4 Floor and Ground Surfaces. Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access 2030 Habersham Trce
measurements shall be permitted to include the full width of the line defining the parking space or access aisle. 505.7.2 Non-Circular Cross Sections. Handrail gripping surfaces with a non-circular cross section shall have a
aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level are not permitted. perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section
Cumming, GA 30041
502.2 Vehicle Spaces. Car parking spaces shall be 96 inches (2440 mm) wide minimum and van parking spaces shall be dimension of 2¼ inches (57 mm) maximum. 954.812.6650
EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
132 inches (3350 mm) wide minimum, shall be marked to define the width, and shall have an adjacent access aisle complying [email protected]
with 502.3. 503.5 Vertical Clearance. Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the
passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide a vertical clearance of 114
EXCEPTION: Van parking spaces shall be permitted to be 96 inches (2440 mm) wide minimum where the access inches (2895 mm) minimum.
aisle is 96 inches (2440 mm) wide minimum.
504 Stairways

504.1 General. Stairs shall comply with 504.

504.2 Treads and Risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall
be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum. Treads shall be 11 inches (280 mm) deep
minimum.

504.3 Open Risers. Open risers are not permitted.

504.4 Tread Surface. Stair treads shall comply with 302. Changes in level are not permitted. Figure 505.7.2 - Handrail Non-Circular Cross Section

EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48.
505.8 Surfaces. Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements 11/30/2022 8:26:01
8:27:10 PM
Advisory 504.4 Tread Surface. Consider providing visual contrast on tread nosings, or at the leading edges of and shall have rounded edges.
treads without nosings, so that stair treads are more visible for people with low vision. OWNER:
505.9 Fittings. Handrails shall not rotate within their fittings.
504.5 Nosings. The radius of curvature at the leading edge of the tread shall be ½ inch (13 mm) maximum. Nosings that
project beyond risers shall have the underside of the leading edge curved or beveled. Risers shall be permitted to slope under 505.10 Handrail Extensions. Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and
the tread at an angle of 30 degrees maximum from vertical. The permitted projection of the nosing shall extend 1½ inches (38 ramp runs in accordance with 505.10.
mm) maximum over the tread below.
EXCEPTIONS:
1. Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg stairs and ramps.
2. In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails
Figure 502.2 - Vehicle Parking Spaces are discontinuous to provide access to seating and to permit crossovers within aisles. 10655 N.E. 4th Street, Suite 606 |
3. In alterations, full extensions of handrails shall not be required where such extensions would be hazardous due to Bellevue, WA 98004
502.3 Access Aisle. Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible plan configuration.
route. Two parking spaces shall be permitted to share a common access aisle.
505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend horizontally above the landing for 12 [email protected]
Advisory 502.3 Access Aisle. Accessible routes must connect parking spaces to accessible entrances. In parking inches (305 mm) minimum beyond the top and bottom of ramp runs. Extensions shall return to a wall, guard, or the
facilities where the accessible route must cross vehicular traffic lanes, marked crossings enhance pedestrian safety, landing surface, or shall be continuous to the handrail of an adjacent ramp run. P:(425) 598-8516
particularly for people using wheelchairs and other mobility aids. Where possible, it is preferable that the accessible PROJECT INFORMATION:
route not pass behind parked vehicles.

Figure 504.5 - Stair Nosings

504.6 Handrails. Stairs shall have handrails complying with 505. MEDFORD, OR
504.7 Wet Conditions. Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of Figure 505.10.1 - Top and Bottom Handrail Extension at Ramps
water.
505.10.2 Top Extension at Stairs. At the top of a stair flight, handrails shall extend horizontally above the landing for Prototype Version 3.0
505 Handrails 12 inches (305 mm) minimum beginning directly above the first riser nosing. Extensions shall return to a wall, guard, August 2022
or the landing surface, or shall be continuous to the handrail of an adjacent stair flight.
505.1 General. Handrails provided along walking surfaces complying with 403, required at ramps
ISSUE
complying with 405, and required at stairs complying with 504 shall comply with 505. DELTA ISSUE DATE DESCRIPTION
NO.
Advisory 505.1 General. Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see
405.8) and on certain stairways (see 504). Handrails are not required on walking surfaces with running slopes less 1 A1 2022.11.30 ISSUED FOR
than 1:20. However, handrails are required to comply with 505 when they are provided on walking surfaces with PERMIT
Figure 502.3 Parking Space Access Aisle running slopes less than 1:20 (see 403.6). Sections 505.2, 505.3, and 505.10 do not apply to handrails provided on
walking surfaces with running slopes less than 1:20 as these sections only reference requirements for ramps and
502.3.1 Width. Access aisles serving car and van parking spaces shall be 60 inches (1525 mm) wide minimum. stairs.

502.3.2 Length. Access aisles shall extend the full length of the parking spaces they serve. 505.2 Where Required. Handrails shall be provided on both sides of stairs and ramps.

502.3.3 Marking. Access aisles shall be marked so as to discourage parking in them. EXCEPTION: In assembly areas, handrails shall not be required on both sides of aisle ramps where a handrail is
provided at either side or within the aisle width.
Advisory 502.3.3 Marking. The method and color of marking are not specified by these requirements but
may be addressed by State or local laws or regulations. Because these requirements permit the van access 505.3 Continuity. Handrails shall be continuous within the full length of each stair flight or ramp run. Inside handrails on
aisle to be as wide as a parking space, it is important that the aisle be clearly marked. switchback or dogleg stairs and ramps shall be continuous between flights or runs.
Figure 505.10.2 - Top Handrail Extension at Stairs
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating.
502.3.4 Location. Access aisles shall not overlap the vehicular way. Access aisles shall be permitted to be placed on
either side of the parking space except for angled van parking spaces which shall have access aisles located on the 505.4 Height. Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum 505.10.3 Bottom Extension at Stairs. At the bottom of a stair flight, handrails shall extend at the slope of the stair
passenger side of the parking spaces. vertically above walking surfaces, stair nosings, and ramp surfaces. Handrails shall be at a consistent height above walking flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing. Extension shall return to
surfaces, stair nosings, and ramp surfaces. a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight.
Advisory 502.3.4 Location. Wheelchair lifts typically are installed on the passenger side of vans. Many
drivers, especially those who operate vans, find it more difficult to back into parking spaces than to back out Advisory 505.4 Height. The requirements for stair and ramp handrails in this document are for adults. When children
into comparatively unrestricted vehicular lanes. For this reason, where a van and car share an access aisle, are the principal users in a building or facility (e.g., elementary schools), a second set of handrails at an appropriate
consider locating the van space so that the access aisle is on the passenger side of the van space. height can assist them and aid in preventing accidents. A maximum height of 28 inches (710 mm) measured to the
top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children.
502.4 Floor or Ground Surfaces. Parking spaces and access aisles serving them shall comply with Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to
302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. help prevent entrapment.

EXCEPTION: Slopes not steeper than 1:48 shall be permitted.

Advisory 502.4 Floor or Ground Surfaces. Access aisles are required to be nearly level in all directions to provide
a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage. Built-up CURRENT ISSUE:
curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes
greater than 1:48.

502.5 Vertical Clearance. Parking spaces for vans and access aisles and vehicular routes serving them shall provide a Figure 505.10.3 - Bottom Handrail Extension at Stairs ISSUE FOR PERMIT
vertical clearance of 98 inches (2490 mm) minimum.

Advisory 502.5 Vertical Clearance. Signs provided at entrances to parking facilities informing drivers of clearances CURRENT ISSUE DATE:
and the location of van accessible parking spaces can provide useful customer assistance.
Figure 505.4 Handrail Height
2022.11.30
502.6 Identification. Parking space identification signs shall include the International Symbol of Accessibility complying with
505.5 Clearance. Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum. DRAWN BY:
703.7.2.1. Signs identifying van parking spaces shall contain the designation “van accessible.” Signs shall be 60 inches (1525
mm) minimum above the finish floor or ground surface measured to the bottom of the sign. PJ/RG
Advisory 502.6 Identification. The required “van accessible” designation is intended to be informative, not CHECKED BY:
restrictive, in identifying those spaces that are better suited for van use.
Enforcement of motor vehicle laws, including parking privileges, is a local matter. LA/RB
PROJECT #:
502.7 Relationship to Accessible Routes. Parking spaces and access aisles shall be designed so that cars and vans, when
parked, cannot obstruct the required clear width of adjacent accessible routes. B4-250-2101
Figure 505.5 Handrail Clearance
SHEET NAME:
Advisory 502.7 Relationship to Accessible Routes. Wheel stops are an effective way to prevent vehicle
overhangs from reducing the clear width of accessible routes. 505.6 Gripping Surface. Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along
their tops or sides. The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length.
Where provided, horizontal projections shall occur 1½ inches (38 mm) minimum below the bottom of the handrail gripping
503 Passenger Loading Zones
surface. ADA 2009
503.1 General. Passenger loading zones shall comply with 503.
EXCEPTIONS:
1. Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of
ACCESSIBILITY
503.2 Vehicle Pull-Up Space. Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) wide
minimum and 20 feet (6100 mm) long minimum.
handrail gripping surfaces shall be permitted to be obstructed along their entire length where they are integral
to crash rails or bumper guards. DETAILS
2. The distance between horizontal projections and the bottom of the gripping surface shall be permitted to be
503.3 Access Aisle. Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up
reduced by 1/8 inch (3.2 mm) for each ½ inch (13 mm) of additional handrail perimeter dimension that
space. Access aisles shall adjoin an accessible route and shall not overlap the vehicular way.
exceeds 4 inches (100 mm). NOTE SHEET NUMBER:
503.3.1 Width. Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) wide minimum.
Advisory 505.6 Gripping Surface. People with disabilities, older people, and others benefit from continuous gripping INFORMATION PROVIDED ON THIS SHEET IS TAKEN FROM 2010 AMERICANS WITH DISABILITIES ACT. IT IS PROVIDED AS A GENERAL
503.3.2 Length. Access aisles shall extend the full length of the vehicle pull-up spaces they serve.

503.3.3 Marking. Access aisles shall be marked so as to discourage parking in them.


surfaces that permit users to reach the fingers outward or downward to grasp the handrail, particularly as the user
senses a loss of equilibrium or begins to fall.
REFERENCE ONLY AND DOES NOT REPRESENT A COMPLETE LISTING OF GUIDELINES NECESSARY TO MEET ACCESSIBILITY CODE
REQUIREMENTS. ADDITIONAL INFORMATION IS PROVIDED ON THE PLUMBING FIXTURE SCHEDULE, DRAWING DETAILS, AND NOTED
THROUGHOUT THE CONSTRUCTION DOCUMENTS.
G-014
0" 1"
54'' MIN

39''-41'' 3' - 6" MAX 2901 Clint Moore Rd, #114


LIGHTING Boca Raton, FL 33496
36'' MAX FIXTURE WHERE
42'' MIN 36'' MAX TO BOT. OF
REFLECTIVE
WALL AT
CORNER
IND. SEE ELEC. 888.901.8008 www.base-4.com
WALL AT WALL AT WALL AT WALL AT SURFACE
CORNER CORNER CORNER CORNER TO BOT. OF ARCHITECT:
42 MIN MIRROR REFLECTIVE
GRAB BAR TPD GRAB BAR TPD GRAB BAR TPD MIR FR SH SURFACE EQ EQ
12'' MAX
24'' MIN
Ricardo J. Muniz-Guillet, AIA
6'' MAX 36'' MIN 24'' MIN

18'' MIN
PTC ON
GRAB BAR SDISP 2030 Habersham Trce

11'' MAX
CONTROL SIDEWALL MIRROR SDISP
PTC SDISP PTC
GRAB BAR 24'' MIN Cumming, GA 30041

2' - 0"
SDISP

4' - 0" MAX


954.812.6650

15'' MIN
48'' MAX

48'' MAX
12'' MIN

40'' MAX

40'' MAX
34''-48''

34''-48''

34''-48''

34''-48''

34''-48''

34''-48''
GRAB BAR
[email protected]
39''-41''

34'' MAX

34'' MAX

34'' MAX
1 1/2" MIN
33''-36''

33''-36''
TPD

2' - 4"
18'' MIN

18'' MIN
17''-19''

17''-19''
7''-9'' LAV PTC LAV
FLOOR LEVEL
42'' MAX 16''-18'' WALL

SIDE WALL BACK WALL


ELEVATION PLAN
DISPENSER OUTLET LOCATION- DISPENSER OUTLET LOCATION- RECESSED DISPENSER DISPENSER IN FRONT OF
PROTRUDING DISPENSER BELOW GRAB BAR PROTRUDING DISPENSER ABOVE GRAB BAR WATER CLOSET

DESCRIPTION TOILET/WATER CLOSETS ACCESSIBLE LAVATORY BASIN/BATHROOMS BATHROOM SINK LAVATORY BASIN/HANDWASH STATION
NOTES : 1. TPD - WHERE THE TOILET PAPER DISPENSER IS LOCATED ABOVE THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 1. SEE PLAN FOR SPECIFIC LOCATION 1. SEE PLAN FOR SPECIFIC LOCATION 1. SEE PLAN FOR SPECIFIC LOCATION
INCHES (610 MM) MINIMUM AND 36 INCHES (915 MM) MAXIMUM FROM THE REAR WALL. WHERE THE DISPENSER IS LOCATED BELOW THE GRAB BAR, THE OUTLET CONDITION CONDITION CONDITION
OF THE DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 INCHES (610 MM) MINIMUM AND 42 INCHES (1065 MM) MAXIMUM FROM THE REAR WALL. THE OUTLET 2. SDISD & PTC-BY OWNER, 2. SDISD & PTC-BY OWNER, INSTALLED BY 2. SDISD & PTC BY OWNER, INSTALLED
OF THE DISPENSER SHALL BE LOCATED 18 INCHES (455 MM) MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FLOOR. INSTALLED BY CONTRACTOR. CONTRACTOR BY CONTRACTOR
2. GB - GRAB BARS. AT NON-ACCESSIBLE WATER CLOSETS OMIT GRAB BARS. 3. ENSURE MIN. 2'-3" X 8" DEEP KNEE 3. ENSURE MIN. 2'-3" X 8" DEEP KNEE SPACE. 3. ENSURE MIN. 2'-3" X 8" DEEP KNEE
3. FLUSH VALVE/CONTROL MUST BE LOCATED ON THE OUTSIDE OR WIDE SIDE OF THE TOILET. SPACE. 4. EXPOSED HOT AND COLD WATER PIPES SPACE.
4. GB BLKG TO BE DESIGNED FOR 250 LB LAT. AND DEAD LOADS.
11/30/2022 8:26:01
8:27:12 PM
4. EXPOSED HOT AND COLD WATER ARE TO BE INSULATED. 4. EXPOSED HOT AND COLD WATER
5. THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM AND 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. PIPES ARE TO BE INSULATED. 5. OTHER THAN WITHIN ACCESSIBLE PIPES ARE TO BE INSULATED. OWNER:
WATER CLOSETS LOCATED IN AMBULATORY ACCESSIBLE COMPARTMENTS SHALL HAVE THE CENTERLINE OF THE WATER CLOSET 17 INCHES (430 MM) MINIMUM 5. OTHER THAN WITHIN ACCESSIBLE DWELLING OR SLEEPING UNITS, MIRRORS
AND 19 INCHES (485 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. DWELLING OR SLEEPING UNITS, SHALL NOT BE REQUIRED OVER THE
MIRRORS SHALL NOT BE REQUIRED LAVATORIES OR COUNTERS IF A MIRROR IS
OVER THE LAVATORIES OR LOCATED WITHIN THE SAME TOILET OR
COUNTERS IF A MIRROR IS BATHING ROOM AND MOUNTED WITH THE
LOCATED WITHIN THE SAME TOILET BOTTOM EDGE OF THE REFLECTING
OR BATHING ROOM AND MOUNTED SURFACE 35 INCHES (890 MM) MAXIMUM
WITH THE BOTTOM EDGE OF THE ABOVE THE FLOOR.
REFLECTING SURFACE 35 INCHES
(890 MM) MAXIMUM ABOVE THE
10655 N.E. 4th Street, Suite 606 |
FLOOR. Bellevue, WA 98004

[email protected]
P:(425) 598-8516
PROJECT INFORMATION:

36'' MIN 36'' MIN CURTAIN ROD CONTROLS

6'' MAX
2" EDGE OF
12'' MAX 24'' MIN 24'' MAX CURTAIN 6'' MAX
ROD SEAT
4" MAX MAX. MAX.
FSB WALL CABINETS
27'' MAX ABOVE, SEE

36'' MIN
MEDFORD, OR
18'' MIN

4'' MAX
18'' MIN

INTERIOR ELEV.
4" MAX 12'' MIN
4" MAX

18'' MIN
18'' MIN

24'' MIN

EDGE OF SDISP OR
GRAB BAR 6" SEAT TO BOT. OF
PTC
GRAB BAR GEL PTC

MAX
GB
GRAB BAR MAX FSB REFLECTIVE

4"
MIR.
GRAB 16'' MIN SURFACE
SHOWER Prototype Version 3.0

10"
36'' MIN
GRAB BAR

3''-6''
BAR
3''-6''

33''-36'' 3''-6''
3''-6''

ACCESS
4" MAX

August 2022

48'' MAX
CLEARANCE
10" ABOVE
36''.

40'' MAX
ABOVE

34''-48''

34''-48''
38'' MAX
39''-41''

UNO.

UNO
33''-36''

CONTROLS
ACCESS CLEARANCE CONTROLS COUNTER COUNTER

17''-19''.
ISSUE

33''-36''
33''-36''

33''-36''

8''-10''

17''-19''.

17'' MAX
15''-16''. 24'' MIN 6" MAX GRAB BAR DELTA ISSUE DATE DESCRIPTION
OR DESK NO.
FLOOR LEVEL

17''-19''.
13 1/2" MIN 1 A1 2022.11.30 ISSUED FOR
PERMIT
SIDE BACK SIDE PLAN SIDE BACK SIDE PLAN

DESCRIPTION BATHTUB ACCESSIBLE SHOWER - ROLL IN SHOWER WITH SEAT SOAP/GEL/FOAM DISP. MIRROR PAPER TOWEL CAB/WR URINAL
NOTES : 1. A PERMANENT SEAT AT THE HEAD END OF THE BATHTUB OR A REMOVABLE IN-TUB SEAT 1. 36" X 60" CLEAR ACCESSIBLE STANDARD ROLL IN SHOWER. DIMENSIONS ARE MINIMUM CLEAR INSIDE INCLUDING FINISHES. 1. LAVATORIES WITH 1. OTHER THAN WITHIN 1. MOUNTING HEIGHT IS 1. URINALS SHALL BE 13 ½
SHALL BE PROVIDED. 2. PROVIDE HAND HELD SHOWER WITH SLIDE BAR, ADJUSTABLE MECHANISE AND BE OPERABLE WITH ONE HAND WITHOUT ENHANCED REACH ACCESSIBLE DWELLING OR INDICATED FOR A INCHES (345 MM) MINIMUM
2. GB BLKG TO BE DESIGNED FOR 250 LB LAT. AND DEAD LOADS. TIGHT GRASPING OR TWISTING OF THE WRIST. MAX. 5 LB FORCE TO OPERATE. RANGE: WHERE SLEEPING UNITS, MIRRORS BOTTOM DISPENCING IN DEPTH MEASURED
3. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT 3. GB BLKG TO BE DESIGNED FOR 250 LB LAT. AND DEAD LOADS. ENHANCED REACH SHALL NOT BE REQUIRED CABINET. MAX PAPER FROM THE OUTER FACE OF
GRASPING,PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE 4. HAND HELD SHOWER MUST HAVE A NON-POSITIVE SHUT OFF AND A HOSE THAT IS 59" LONG MIN. RANGE IS REQUIRED AT OVER THE LAVATORIES OR SOURCE HEIGHT IS 48". THE URINAL RIM TO THE
OPERABLE PARTS SHALL BE 5.0 POUNDS 5. A MEANS TO HOLD THE HAND SHOWER WAND WHILE IN THE ON OR OFF POSITION SHALL BE LOCATED AT A HEIGHT OF 38 LAVATORIES, FAUCETS COUNTERS IF A MIRROR IS FINISHED WALL SURFACE.
4. THE HEIGHT OF BATHTUB SEATS SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES (485 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE SHOWER FINISH FLOOR. AND SOAP DISPENSER LOCATED WITHIN THE SAME
MM) MAXIMUM ABOVE THE BATHROOM FLOOR, MEASURED TO THE TOP OF THE SEAT. 6. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING, OR CONTROLS SHALL HAVE TOILET OR BATHING ROOM
REMOVABLE IN-TUB SEATS SHALL BE 15 INCHES (380 MM) MINIMUM AND 16 INCHES (405 MM) TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5.0 POUNDS A REACH DEPTH OF 11 AND MOUNTED WITH THE
MAXIMUM IN DEPTH. REMOVABLE IN-TUB SEATS SHALL BE CAPABLE OF SECURE PLACEMENT. 7. THE HEIGHT OF SHOWER COMPARTMENT SEATS SHALL BE 17 INCHES MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM INCHES MAXIMUM BOTTOM EDGE OF THE
PERMANENT SEATS SHALL BE 15 INCHES (380 MM) MINIMUM IN DEPTH AND SHALL EXTEND ABOVE THE BATHROOM FLOOR, MEASURED TO THE TOP OF THE SEAT. IN TRANSFER-TYPE AND ALTERNATE ROLL-IN-TYPE REFLECTING SURFACE 35
FROM THE BACK WALL TO OR BEYOND THE OUTER EDGE OF THE BATHTUB. PERMANENT SHOWERS,THE SEAT SHALL EXTEND ALONG THE SEAT WALL TO A POINT WITHIN 3 INCHES (75 MM) OF THE COMPARTMENT INCHES (890 MM) MAXIMUM
SEATS SHALL BE POSITIONED AT THE HEAD END OF THE BATHTUB. ENTRY. IN STANDARD ROLL-IN-TYPE SHOWERS, THE SEAT SHALL EXTEND FROM THE CONTROL WALL TO A POINT WITHIN 3 ABOVE THE FLOOR.
INCHES (75 MM) OF THE COMPARTMENT ENTRY

CURTAIN
36''. 36''. CURRENT ISSUE:
ROD 36''.
WALL, WHERE 2" TO BOT. OF
CURTAIN TO BOT. OF
INDICATED. REFLECTIVE
ROD REFLECTIVE
SURFACE
WALL CABINETS ABOVE, SURFACE
SEE INTERIOR ELEV.
GRAB BAR
GRAB BAR.L FSB
6" ISSUE FOR PERMIT
4" 15'' MAX SHAPE
CONTROL 4"
WALL
SDISP
33''-36'' 3''-6'' 18'' MIN.

CONTROLS
PTC, MOUNT ON SIDE
CL CL
33''-36'' 3''-6''18'' MIN.

12''.
4" MAX
WALL WHERE 18''.
CURRENT ISSUE DATE:
18'' MIN

INDICATED. GRAB BAR L SHAPE


GRAB BAR MIR. MIR.
COUNTER TOP, DESK &
CABINETS, SEE INTERIOR ELEV. SNC
DCS
CH 2022.11.30
SHOWER ACCESS
36''.

DRAWN BY:
48'' MAX

CLEARANCE

40''-48''

40'' MAX.
FSB
34''-48''

34'' MAX.

35'' MAX
38'' MIN
38''-43''
36'' MAX

39''-41''

28''-34''
PJ/RG

34''.
17''-19''

17''-19''

SINK WHEELCHAIR ACCESSIBLE STANDING


CHECKED BY:
FLOOR LEVEL PERSON

LA/RB
SIDE BACK SIDE PLAN PROJECT #:

B4-250-2101
DESCRIPTION COUNTER TOP SINK DF, DRINKING FOUNTAIN OR EWC, ELECTRIC WATER COOLER ACCESSIBLE SHOWER - TRANSFER TYPE SHOWER WITH SEAT SANITARY NAPKIN CABINET DIAPER CHANGING STATION COAT HOOKS MIRROR SHEET NAME:
NOTES : 1. SEE PLAN FOR SPECIFIC 1. 36" X 36" CLEAR ACCESSIBLE TRANSFER TYPE SHOWER. DIMENSIONS ARE ABSOLUTE CLEAR INSIDE INCLUDING 1. ENSURE MAX. 4'-0" 1. ENSURE MIN. 2'-3" MIRROR LOCATED ABOVE
LOCATION CONDITION 1. WHERE A SINGLE DF IS REQUIRED IT SHALL BE FINISHES. HIGH TO OPERABLE HIGH X 8" DEEP KNEE LAVATORIES, SINKS OR COUNTER
INSTALLED AS AN ACCESSIBLE DF.
2. SDISD & PTC-BY OWNER,
INSTALLED BY CONTRACTOR 2.
3.
ENSURE MIN. 2'-3" X 8" DEEP KNEE SPACE.
SPOUT HEIGHT FOR ADA IS MAX 36" AFL. FOR
2. PROVIDE HAND HELD SHOWER WITH SLIDE BAR, ADJUSTABLE MECHANISE AND BE OPERABLE WITH ONE HAND
WITHOUT TIGHT GRASPING OR TWISTING OF THE WRIST. MAX. 5 LB FORCE TO OPERATE.
CONTROLS AFL. SPACE.
2. PULL DOWN HANDLE
SHALL BE MOUNTED WITH THE
BOTTOM EDGE OF THE REFLECTTING STANDARD
3. ENSURE MIN. 2'-3" X 8" DEEP 3. GB BLKG TO BE DESIGNED FOR 250 LB LAT. AND DEAD LOADS. TO BE LOCATED 48" MAX URFACE 40 INCHES MAX. ABOVE THE

4.
KNEE SPACE.
EXPOSED HOT AND COLD
STANDING PEOPLE SPOUT MOUNTING HEIGHT IS
38"-43" AFL.
4.
5.
HAND HELD SHOWER MUST HAVE A NON-POSITIVE SHUT OFF AND A HOSE THAT IS 59" LONG MIN.
OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING, OR
AFL. FLOOR. MIRROR NOT LOCATED ABOVE
THE LAV. SINKS SHALL BE MOUNTER
MOUNTING
WATER PIPES ARE TO BE
INSULATED.
TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5.0 POUNDS WITH THE BOTTOM EDGE OF THE
REFLECTING SURFACE 35 INCHES MAX.
DETAILS (2015)

SHEET NUMBER:

G-020
0" 1"
A3 ASSEMBLY B BUSINESS A3 ASSEMBLY
A3 ASSEMBLY
Accessory Accessory
596.71 SF POOL
117.47 SF 965.62 SF 22.24 SF 2901 Clint Moore Rd, #114
STORAGE
170 Boca Raton, FL 33496
888.901.8008 www.base-4.com
0 MIN
ARCHITECT:
0 MIN

A3 ASSEMBLY P.F.E
Accessory Ricardo J. Muniz-Guillet, AIA
B10 2030 Habersham Trce
120.39 SF POOL EQUIP. Cumming, GA 30041
169 B11
B BUSINESS PATIO AREA 954.812.6650
Accessory 171 [email protected]
EGRESS 3
167.44 SF CAPACITY 170
UNISEX LOAD 80
S1 STORAGE A2 ASSEMBLY - 168
0 MIN

KITCHEN B9
732.43 SF 0 MIN

UNISEX POOL DECK 0 MIN

350.66 SF
0 MIN
0 MIN 0 MIN

R1 RESIDENTIAL 167 AREA A3 ASSEMBLY


P.F.E P.F.E
A4 166 Accessory
3631.49 SF 0 MIN
PATIO 111.44 SF
ENGINEERING DRYERS RESTROOM
OFFICE ELECTRICAL STORAGE 162 LAUNDRY 0 MIN
173 FIRE PUMP
157 158 161 DISCHARGE 172
EMPLOYEE 0 MIN

164
S1 STORAGE
BREAKROOM 0 MIN

P.F.E
160
90 MIN 90 MIN
124.52 SF
B1 LAUNDRY
STAIR#1
163 P.F.E
0 MIN 0 MIN

0 MIN
ELEVATOR 195 11/30/2022
2022-11-308:26:01 PM
23:05:36
KING STUDIO KING ONE SERVERY
45 MIN
LOBBY A2 ASSEMBLY -
MECHANICAL OWNER:
KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO SUITE KING STUDIO BEDROOM PBX MANAGERS 174 W/O KITCHEN
0 MIN

178 WORK
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. 113 SUITE CONN. SUITE " 156 OFFICE
3 /4 155 STATION 0 MIN

101 103 105 107 109 111 115 ACC(RIS) '-3 176 104.57 SF
2 45
0 MIN
177
117 FOOR PREP 0 MIN

B7 159 BREAKFAST
45 MIN
45 MIN 45 MIN 45 MIN B6 REGISTRATION
179 UP
HOME2 175
0 MIN MARKET F.E.C EGRESS 2
CAPACITY 170
P.F.E 180
MECH. P.F.E LOAD 80
10655 N.E. 4th Street, Suite 606 |
R1 RESIDENTIAL ICE B6
183 0 MIN
Bellevue, WA 98004
P.F.E
0 MIN 0 MIN
B4
Accessory 154 A5
0 MIN

841.49 SF 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 45 MIN A2 0 MIN

A2 ASSEMBLY - [email protected]
F.E.C CORRIDOR A3 CORRIDOR
EGRESS 4 0 MIN
45 MIN

W/O KITCHEN P:(425) 598-8516


CAPACITY 170 F.E.S 100 F.E.C 100.1
LOBBY ENTRY
LOAD 80 221 SF PROJECT INFORMATION:
90 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN
34" 181 VESTIBULE ALCOVE
0 MIN
001 186 MECHANICAL
WOMENS 0 MIN

34" TOILET 185


STAIR#2 STORAGE
153
196 144 0 MIN

45 MIN
GUEST
45 MIN LAUNDRY
133" P.F.E 184
S1 STORAGE KING ONE
133" B3 MEDFORD, OR
BEDROOM KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN
64.67 SF SUITE
0 MIN

MENS TOILET
A2 ASSEMBLY -
SUITE SUITE SUITE SUITE SUITE CONN. SUITE CONN. STUDIO SUITE STUDIO SUITE STUDIO SUITE
106 152
W/O KITCHEN
108 110 112 114 116 118 120 122 124 FITNESS
STORAGE A2 Accessory
151
ROOM Prototype Version 3.0
A1 63.58 SF
0 MIN
182 August 2022
B8 0 MIN

ISSUE
DELTA ISSUE DATE DESCRIPTION
B5 NO.

SALES OFFICE 297" 1 A1 2022.11.30 ISSUED FOR


150
0 MIN
PERMIT
0 MIN

A2 ASSEMBLY - VESTIBULE
R1 RESIDENTIAL W/O KITCHEN 002
4222.46 SF Accessory A2 ASSEMBLY - EGRESS 1
A3 ASSEMBLY
CAPACITY 240
118.32 SF W/O KITCHEN LOAD 136
740.42 SF
A2 ASSEMBLY - 3619.89 SF
W/O KITCHEN
EGRESS 5
Accessory
CAPACITY 170
50.13 SF LOAD 80

PATH OF TRAVEL - 1ST FLOOR


1 1ST FLOOR LIFE SAFETY & OCCUPANCY PLAN MARK FROM ROOM TO ROOM DISTANCE
A-010 1" = 10'-0" COMMON EGRESS PATH
B1 LAUNDRY 163 VESTIBULE 002 124' - 10"
B3 FITNESS ROOM 182 ENTRY ALCOVE 186 64' - 10"
B4 ELEVATOR LOBBY 174 ENTRY ALCOVE 186 51' - 2"
B5 SALES OFFICE 150 LOBBY 181 87' - 1"
B6 FOOR PREP 159 VESTIBULE 002 132' - 0"
B7 KING ONE BEDROOM SUITE ACC(RIS) 117 CORRIDOR 100 139' - 7"
B8 QUEEN QUEEN STUDIO SUITE 124 CORRIDOR 100 179' - 6"
B9 UNISEX 167 PATIO AREA 171 68' - 9"
B10 POOL DECK AREA 166 PATIO AREA 171 67' - 8" CURRENT ISSUE:
B11 POOL EQUIP. 169 PATIO AREA 171 92' - 5"
MAXIMUM TRAVEL DISTANCE
A1
A2
LOBBY 181
LOBBY 181
VESTIBULE 002
LOBBY 181
53' - 10"
64' - 6"
ISSUE FOR PERMIT
A3 CORRIDOR 100 CORRIDOR 100 144' - 7"
A4 POOL DECK AREA 166 PATIO AREA 171 60' - 10"
CURRENT ISSUE DATE:
A5 LOBBY 181 ENTRY ALCOVE 186 46' - 7"
2022.11.30
DRAWN BY:
OCCUPANCY GROUP LEGEND RATED WALL LEGEND LIFE SAFETY SYMBOL KEY EGRESS DOOR LIST - 1ST FLOOR AREA OCCUPANCY - 1ST FLOOR SEATING OCCUPANCY - 1ST FLOOR
OCCUPANCY OCCUPANT OCCUPANT EGRESS EGRESS WIDTH LINEAR OCCUPANT OCCUPANT EGRESS EGRESS WIDTH
PJ/RG
THE CLEAR WIDTH OF THE #1 VESTIBULE (exterior) DOOR SHALL BE [4'0'']
THE CALCULATIONS HAVE BEEN DONE FOR THE CLEAR WIDTH EGRESS I.E... AREA LOAD FACTOR LOAD FACTOR REQUIRED INCHES LOAD FACTOR LOAD FACTOR REQUIRED CHECKED BY:
1 HR FIRE PARTITION 2 HR RATED EXIT LIGHT SIGN
DOOR EGRESS EGRESS A2 ASSEMBLY - KITCHEN BAR / BENCH SEATING
STANDARD PARTITION & CORRIDORS SHAFT LA/RB
MAIN OCCUPANCY EGRESS # DOOR WIDTH CAPACITY LOAD 350.66 SF 200 2 0.2 0.4 297" 1 PERSON / 18" 17 0.2 3.4
A2 ASSEMBLY - R1 RESIDENTIAL A2 ASSEMBLY A2 ASSEMBLY - W/O KITCHEN BOOTH SEATING
PROJECT #:
KITCHEN 1 HR FIRE BARRIER EGRESS #
Accessory
ANCILLARY FUNCTION 1ST FLOOR
OCCUPANCY SEPARATION EGRESS #1 (IF AVAILABLE) 150A-EXTERIOR VESTIBULE 4400.9 SF 15 297 0.2 59.4 333" 1 PERSON / 24" 16 0.2 3.2 B4-250-2101
DOOR LOAD 100 SF 1 8' - 0" 240 136
CAPACITY X SQUARE FOOTAGE DOOR A3 ASSEMBLY 630" 33 6.6
LOAD X
CAPACITY SHEET NAME:
1 HR EXTERIOR WALL VESTIBULE EXTERIOR 2184.34 SF 50 48 0.2 9.6
2 8' - 0" 170 80
A2 ASSEMBLY - S1 STORAGE DOOR LOAD COMMON PATH OF EGRESS DOOR B BUSINESS TOTAL OCCUPANCY - 1ST FLOOR
W/O KITCHEN 2 HR FIRE BARRIER DOOR FIRE PATH OF TRAVEL
3
4
OUTDOOR PATIO
CORRIDOR TO EXTERIOR
3' - 0"
3' - 0"
170
170
80
80
887.77 SF
R1 RESIDENTIAL
100 10 0.2 2
OCCUPANCY TOTAL OCCUPANT EGRESS TOTAL EGRESS WIDTH 1ST FLOOR LIFE
STAIRS & SHAFTS RATING TYPE LOAD FACTOR REQUIRED
45 MIN

PORTABLE FIRE MAXIMUM PATH


5 LOBBY 2' - 10 1/4" 170 80 8695.44 SF 200 46 0.2 9.2
AREA TOTAL 409 AS INDICATED 81.8 SAFETY AND
P.F.E. S1 STORAGE
A3 ASSEMBLY 2 HR EXTERIOR WALL EXTINGUISHER
FIRE EXTINGUISHER
A1 - 420'-11"
OF TRAVEL 921.61 SF 300 5 0.2 1
SEATING TOTAL
GRAND TOTAL
33
442
AS INDICATED 6.6
88.4
OCCUPANCY
F.E.C. PATH OF TRAVEL 17440.72 SF 408 81.6
CABINET MARK EGRESS WIDTH PROVIDED : (36'' x 5 EXITS) = 180''
PLAN
F.E.S. FIRE EXIT SIGN COMMON PATH OF
B1
B BUSINESS ROOM WITH
EGRESS MARK GENERAL NOTES SHEET NUMBER:
COMMUNICATION 420" BOOTH SEATING
1. OUTDOOR PATIO AREAS HAVE BEEN EXCLUDED FROM CALCULATION AS

A-010
FEATURES
LINEAR INCHES THEY ARE CALCULATED IN OVERALL HOTEL OCCUPANCY LOADS.
ACCESSIBLE 2. OCCUPANT LOADS ARE ROUNDED UP BEFORE CALCULATING THE SUM TO
420" BAR / BENCH SEATING
ROOM PRESENT THE WORST-CASE-SCENARIO.

0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

R1 RESIDENTIAL R1 RESIDENTIAL
6977.64 SF Accessory
673.29 SF

HOUSEKEEPING ELEC/PBX
241 242

0 MIN 11/30/2022
2022-11-308:26:01 PM
23:05:52
OWNER:
0 MIN

KING STUDIO KING ONE


KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO SUITE KING STUDIO BEDROOM QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN ELEVATOR
213
ACC(TUB) STUDIO SUITE STUDIO SUITE STUDIO SUITE LOBBY
201 203 205 207 209 211 215 221 223 225 227
217 229 231 233 240
10655 N.E. 4th Street, Suite 606 |
45 MIN 45 MIN 45 MIN 45 MIN
DN UP
Bellevue, WA 98004
STAIR#1
295
ICE [email protected]
243 P:(425) 598-8516
R1 RESIDENTIAL 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 0 MIN
PROJECT INFORMATION:
Accessory F.E.C. CORRIDOR
1281.59 SF F.E.S. A1 200 F.E.C. A2 F.E.C.
90 MIN 0 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN 20 MIN
EGRESS 2
CAPACITY 170
LOAD 43
STAIR#2
296 STORAGE
UP 244
MEDFORD, OR
45 MIN
45 MIN

KING ONE QUEEN QUEEN


S1 STORAGE QUEEN QUEEN STUDIO SUITE-
BEDROOM
SUITE KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN STUDIO SUITE ACC. Prototype Version 3.0
69.55 SF SUITE SUITE SUITE SUITE SUITE CONN. SUITE CONN. STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE CONN. CONN.(RIS) August 2022
206 216
208 210 212 214 218 220 222 224 226 228 230 232 234 236 238
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.

B3 1 A1 2022.11.30 ISSUED FOR


PERMIT

B1

R1 RESIDENTIAL
7579.41 SF

1  2ND FLOOR LIFE SAFETY & OCCUPANCY PLAN 


A-011 1" = 10'-0"

CURRENT ISSUE:

ISSUE FOR PERMIT

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
OCCUPANCY GROUP LEGEND RATED WALL LEGEND LIFE SAFETY SYMBOL KEY EGRESS DOOR LIST - UPPER FLOORS AREA OCCUPANCY - UPPER FLOORS GENERAL NOTES
OCCUPANCY OCCUPANT OCCUPANT EGRESS EGRESS WIDTH
PJ/RG
THE CLEAR WIDTH OF THE #1 VESTIBULE (exterior) DOOR SHALL BE [XXXX] 1. OUTDOOR PATIO AREAS HAVE BEEN EXCLUDED FROM CALCULATION AS
THE CALCULATIONS HAVE BEEN DONE FOR THE CLEAR WIDTH EGRESS I.E... AREA LOAD FACTOR LOAD FACTOR REQUIRED CHECKED BY:
1 HR FIRE PARTITION EXIT LIGHT SIGN THEY ARE CALCULATED IN OVERALL HOTEL OCCUPANCY LOADS.
2 HR RATED 2. OCCUPANT LOADS ARE ROUNDED UP BEFORE CALCULATING THE SUM TO
STANDARD PARTITION & CORRIDORS DOOR EGRESS EGRESS LA/RB
SHAFT DOOR WIDTH R1 RESIDENTIAL PRESENT THE WORST-CASE-SCENARIO.
MAIN OCCUPANCY EGRESS # CAPACITY LOAD
R1 RESIDENTIAL A2 ASSEMBLY 16511.93 SF 200 84 0.2 16.8 PROJECT #:
1 HR FIRE BARRIER EGRESS #
Accessory
ANCILLARY FUNCTION
OCCUPANCY SEPARATION EGRESS #1 (IF AVAILABLE) 1 STAIRCASE#1 2ND FLOOR 3' - 0" 170 43 S1 STORAGE B4-250-2101
DOOR LOAD 100 SF
CAPACITY X
CAPACITY SQUARE FOOTAGE 2 STAIRCASE#2 2ND FLOOR 3' - 0" 170 43 69.55 SF 300 1 0.2 0.2
LOAD X SHEET NAME:
1 HR EXTERIOR WALL 16581.48 SF 85 17

S1 STORAGE
DOOR LOAD COMMON PATH OF EGRESS
PATH OF TRAVEL - UPPER FLOORS UPPER FLOOR
DOOR FIRE
2 HR FIRE BARRIER
STAIRS & SHAFTS RATING
PATH OF TRAVEL REFER TO LIFE SAFETY SYMBOL KEY FOR VISUAL REPRESENTATION OF THE TOTAL OCCUPANCY - UPPER FLOORS LIFE SAFETY
45 MIN LINES ON PLAN

2 HR EXTERIOR WALL P.F.E.


PORTABLE FIRE
EXTINGUISHER A1 - 420'-11"
MAXIMUM PATH
OF TRAVEL
MARK
FROM
ROOM
TO
ROOM
DISTANCE
OCCUPANCY
TYPE
TOTAL OCCUPANT
LOAD
EGRESS
FACTOR
TOTAL EGRESS WIDTH
REQUIRED AND
F.E.C. FIRE EXTINGUISHER
CABINET
PATH OF TRAVEL
MARK
AREA TOTAL
SEATING TOTAL 0
10
AS INDICATED
AS INDICATED
0
5
OCCUPANCY
F.E.S. FIRE EXIT SIGN B1 COMMON PATH OF A1
A2
CORRIDOR 200
CORRIDOR 200
STAIR#2 296
STAIR#1 295
146' - 10"
138' - 8"
GRAND TOTAL 10 5 PLAN
EGRESS MARK EGRESS WIDTH PROVIDED : (36'' x [1] EXITS) + (36'' x [1] EXIT) = 72''
ROOM WITH B1 QUEEN QUEEN STUDIO STAIR#2 296 182' - 5" SHEET NUMBER:
COMMUNICATION 420" BOOTH SEATING
SUITE 220

A-011
FEATURES
LINEAR INCHES B3 QUEEN QUEEN STUDIO STAIR#1 295 163' - 0"
ACCESSIBLE SUITE 222
420" BAR / BENCH SEATING
ROOM

0" 1"
1 2 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
A-604 A-601 A-603

A-602

2901 Clint Moore Rd, #114


1 Boca Raton, FL 33496
252' - 9 1/4"
888.901.8008 www.base-4.com
4 1/2" 1' - 1 1/2" ARCHITECT:
12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 10 3/4" 13' - 1" 3' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4"
Ricardo J. Muniz-Guillet, AIA
6' - 9 1/8" 13' - 0 3/8" 13' - 0 7/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 1/2" 6' - 9 1/4" 5' - 9 3/8" 14' - 1 3/8" 5' - 9 3/4" 15' - 9 1/2" 17' - 2" 5' - 8 1/2" 12' - 9 3/4" 42' - 3 3/4" 11' - 11" 16' - 6 3/4" 2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]
POOL
ER-6.1 ER-6.1 IR-6.1 ER-6.1 ER-6.1 ER-6.1 STORAGE CM-8.1
170

P POOL EQUIP. P

8' - 2 1/4"
170

169 169
CM-8.1
IR-6.1
ER-6.1
SHOWER
IR-6.1
23' - 7 3/4"

23' - 7 3/4"
IR-6.1
IR-6.1 ER-6.1
29' - 0 1/4"

16' - 0 1/4"
INDOOR
UNISEX SF-10
POOL
168 168 PATIO AREA
VESTIBULE
IR-6.1 165 SF-9 171
UNISEX 3 11/30/2022
2022-12-018:26:01 PM
20:03:37

4' - 9 3/4"
171 ER-6.1
167
POOL DECK
165B
A-809
N 167 N
6' - 0" 4' - 9 3/4"

173 172
AREA OWNER:
ER-6.2 ER-6.2 IP-6.1 SF-8
4 W4 ER-6.1 IR-6.1 IP-4.1 IR-6.2 166

3' - 10 1/4"
M A-812 158B M
PATIO
3' - 10 1/4"

ER-6.1 DRYERS

6' - 0"
ER-6.1
6' - 0"

ER-6.1 ER-6.1 A ENGINEERING IP-6.1 IR-6.1 IR-4.1 RESTROOM FIRE PUMP A


STORAGE
W4 W4 W4 W4 W4 W4 W4 W4 A-452 OFFICE 162 LAUNDRY 165A A-310A
161 173 172
DISCHARGE SF-7
L 157 EMPLOYEE 162 L
ER-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 157 ELECTRICAL BREAKROOM 161
164 IR-6.2 IR-6.1 ER-6.1
ER-6.1
W4 W4 158 160
164B 164A

LAUNDRY IR-6.2 EL-6.1 K


K IR-4.2 IP-4.1 10655 N.E. 4th Street, Suite 606 |
1' - 4 3/4"

158A
IR-4.1 IR-4.1 ST-6.1
160
IR-4.1 163 EL-6.1 Bellevue, WA 98004

1' - 4 3/4"
IF-6.1 IP-4.1 GD-6.1 CLOSET ELEV#2
176B
J 163 ELEVATOR J

46' - 2 1/4"
SERVERY WORK LOBBY
KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO MECHANICAL PBX 159B MANAGERS
17' - 4 1/2"

17' - 4 1/2"
KING ONE
SUITE 178 STATION ST-6.2 [email protected]
30' - 1 1/2"

SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. BEDROOM IP-4.1 176A OFFICE 174
156 155 FOOR PREP
101 103 105 107 109 111 113 115 SUITE 177 FR-4.1 P:(425) 598-8516
2 155 IR-4.1
159 IR-6.4 176 IR-6.1 C
ACC(RIS)

107' - 4 1/2"
IP-6.1
177
IR-6.1 A-308A PROJECT INFORMATION:

3' - 4 1/4"
A-602 ELEV#1
117 BREAKFAST REGISTRATION STAIR#1 H
IP-6.1 IP-4.1 UP
175 EL-6.1
107' - 4 1/2"

179 EL-6.1 195


H IP-4.1
3' - 4 1/4"

159A
MECH.
ST-6.1
FR-4.1 G

3' - 11 1/2"
183 1

5' - 8 1/2"
G ICE IR-6.1 CR-6.1
HOME2 183
179A 179B A-809
SF-6
3' - 0 1/8"
2' - 2 7/8"

154 IP-6.1 MARKET VESTIBULE


F F
3' - 11 1/2"
5' - 8 1/2"

156
2 180
CLEAR

CLEAR
ER-6.1 ERV CORRIDOR 001 001A
ENTRY
5' - 0"

5' - 0"
CR-6.1 CORRIDOR CR-6.1 CR-6.1 154 001B

A-604 100 SHAFT 100.1 CR-6.2 6 ALCOVE


ST-6.1 ST-6.1 CR-6.1 100 CR-6.1 CR-4.1 MEDFORD, OR
A-809 SF-5 186 MECHANICAL PORTE
E 196B 144
IP-4.1
IR-6.1
COCHERE
E
IR-6.1 185
SF-4
9' - 10 1/2"

9' - 10 1/2"
196A
STAIR#2 WOMENS FR-6.1 ABOVE
CR-6.1
7' - 7 1/8"
2' - 5 3/4"

182
TOILET 1 A-603 Prototype Version 3.0
A-601 1 196 STORAGE IR-6.1
153 LOBBY IR-6.1
IR-6.1 August 2022

20' - 6 3/4"
UP ST-6.1 144 GUEST
ST-6.2
153 181 185
LAUNDRY
D D ISSUE
ST-6.3 CR-4.1 184 DELTA ISSUE DATE DESCRIPTION
NO.
IR-6.1
KING ONE GD-6.1 ER-6.2
BEDROOM KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN
20' - 0 3/4"

KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN QUEEN QUEEN 1 A1 2022.11.30 ISSUED FOR
20' - 0 3/4"

152
SUITE

20' - 0 3/4"
SUITE SUITE SUITE SUITE SUITE CONN. SUITE CONN. STUDIO SUITE STUDIO SUITE STUDIO SUITE MENS TOILET PERMIT
A
106 108 110 112 114 116 118 120 122 124 STORAGE 152 A-303A
2 151
151
A-600 GD-6.1 FITNESS

12' - 8"
150 IR-6.1 ROOM SF-1
SF-3
ER-6.1 IP-4.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 GD-6.1 IR-4.1 FR-6.1 182
C C
5' - 11 1/4"
10" 5' - 11 1/4"

5' - 11 1/4"
ER-6.1 W4 W4 W4 W4 W4 W4 W4 ER-6.1 W4 ER-6.1 VESTIBULE

3' - 8 1/2"
181

GD-6.1 GD-6.1 IF-6.1 SF-2 ER-6.1 002 002A GD-6.1 ER-6.2 2


B ER-6.2 B
OUTDOOR A-809
W4 W4 W4 ER-6.1 W3 ER-6.1 SF-3
LOUNGE W3 W3

10"
ER-6.2 ER-6.2
10"

SALES OFFICE 4 188 A


A 5
A-809
A-812 150 1 CANOPY
A-811 ABOVE

TRELLIS
N ABOVE
1' - 0 1/2" 1 1/4"
12' - 8 1/4" 6' - 5 5/8" 12' - 7" 14' - 1 1/8" 13' - 0 3/4" 13' - 2" 12' - 11 1/2" 13' - 2 1/8" 13' - 0 1/2" 6' - 3 7/8" 6' - 8" 13' - 3" 12' - 11" 13' - 4 5/8" 6' - 7 3/8" 3' - 3 3/4" 31' - 8" 4' - 1" 11' - 8" 6' - 9" 13' - 0 1/4" 10' - 8"
CURRENT ISSUE:
12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 10 3/4" 13' - 1" 3' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4"
252' - 9 1/4" 4 1/2" 1' - 1 1/2" ISSUE FOR PERMIT
1
1  1ST FLOOR 
A-100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
3/32" = 1'-0" CURRENT ISSUE DATE:
A-600
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
CHECKED BY:
BASE4 NOTES
LA/RB
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE PROJECT #:
NOTED B4-250-2101
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE. SHEET NAME:
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
1ST FLOOR
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF PLAN
GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. SHEET NUMBER:
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION

A-100
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS

0" 1"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
A-602

1 2 2
A-604 1 A-601 A-603

252' - 9 1/4" 2901 Clint Moore Rd, #114


4 1/2"
Boca Raton, FL 33496
1' - 1 1/2"
888.901.8008 www.base-4.com
12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 10 3/4" 13' - 1" 3' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4"
ARCHITECT:
6' - 9 1/8" 13' - 0 3/8" 13' - 0 7/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 1/2" 6' - 9 1/4" 5' - 9 3/8" 14' - 1 3/8" 5' - 9 3/4" 6' - 9" 13' - 2 1/2" 13' - 0" 13' - 2" 13' - 0" 13' - 2" 13' - 0" 17' - 11 1/2" 18' - 9 3/4"
Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

1 A
A-806 A-311A
A
A-406 2
A-340 ER-6.1
N N
4' - 9 3/4"

4' - 9 3/4"
6' - 0" 4' - 9 3/4"

ER-6.2 W1

6' - 0"
6' - 0"

W1 W1 W1 W1 W1 W1 ER-6.1 IR-6.1 ER-6.1


M M

3' - 10 1/4"
ELEC/PBX FR-4.1
ER-6.1 ER-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 HOUSEKEEPING
11/30/2022
2022-12-018:26:01 PM
20:03:45
3' - 10 1/4"

ER-6.1 W1 W1 W1 W1 W1 W1 W1 W1 ER-6.1 FR-4.1 242 FR-4.1


241
L LINEN L
CHUTE OWNER:
ER-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 EL-6.1 242 ST-6.1 ELECTRIC
W1 ER-6.1 W1GD-6.1 CHASE
K EL-6.1
K

1' - 4 3/4"
241
1' - 4 3/4"

IF-6.1 ERV
IP-4.1

43' - 6 3/8"
J KING ONE FR-4.1
SHAFT J
QUEEN QUEEN ST-6.2
KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO BEDROOM QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN
17' - 4 1/2"

17' - 4 1/2"
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE SUITE CONN. SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE ELEVATOR
LOBBY 2
32' - 8 5/8"

201 203 205 207 209 211 213 215 ACC(TUB) 221 223 225 227 229 231 233 A-320
2 240 10655 N.E. 4th Street, Suite 606 |
217
A-602 A 5 EL-6.1 Bellevue, WA 98004
2
A-313A A-809 A-330
H H
3' - 4 1/4"

3' - 4 1/4"
STAIR#1 ERV [email protected]
FR-4.1 ICE SHAFT
EL-6.1
295 P:(425) 598-8516
G 243 G
ER-6.1 PROJECT INFORMATION:
IR-6.1 ER-6.1 A
F
3' - 11 1/2"

3' - 11 1/2"
5' - 8 1/2"

9' - 10 1/2" 5' - 8 1/2"


240
A-313B

83' - 2"
2
CLEAR

CLEAR
F
65' - 7"

ERV
5' - 0"

5' - 0"
CR-6.1 ERV CORRIDOR CR-6.1 CR-6.1 CR-6.2
A-604 W2 SHAFT SHAFT SH-3.1 W2
ST-6.1 CR-6.1 200 CR-6.1 CR-6.1 9
E 296 244
A-801.A E
ER-6.1 ST-6.1 ER-6.1
9' - 10 1/2"

ST-6.2 STAIR#2 1 A-603


A-601 1 STORAGE
296 IR-6.1
UP ST-6.1 244
2 MEDFORD, OR
D D
32' - 9 3/8"

A-321 ST-6.3 PORTE


QUEEN QUEEN COCHERE
KING ONE QUEEN QUEEN

39' - 6 5/8"
STUDIO SUITE- BELOW
Prototype Version 3.0

20' - 0 3/4"
BEDROOM KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN STUDIO SUITE ACC.
SUITE
20' - 0 3/4"

SUITE SUITE SUITE SUITE SUITE CONN. SUITE CONN. STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE CONN. CONN.(RIS) A August 2022
206 208 210 214 216 218 220 222 224 226 228 230 232 234 236 238
212 A-402
ISSUE
2 DELTA ISSUE DATE DESCRIPTION
NO.
A-600
GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 ER-6.1 1 A1 2022.11.30 ISSUED FOR
ER-6.1 IP-4.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 PERMIT
C C
5' - 11 1/4"
5' - 11 1/4"

10" 5' - 11 1/4"


ER-6.1 W1 W1 W1 W1 W1 W1 W1 W1 ER-6.1
ER-6.1 ER-6.2 ER-6.1
B B
W1 W1 W1
10"

A ER-6.1 W1 W1 W1 W1 W1
ER-6.1 ER-6.1 W1 W1 ER-6.2
A A-404 A

TRELLIS
BELOW

12' - 8 1/4" 6' - 5 5/8" 12' - 7" 14' - 1 1/8" 13' - 0 3/4" 13' - 2" 12' - 11 1/2" 13' - 2 1/8" 13' - 0 3/4" 6' - 3 1/2" 6' - 8" 13' - 3" 12' - 11" 13' - 4 1/2" 12' - 10" 13' - 4" 12' - 10" 13' - 3" 6' - 2 1/2" 6' - 9 1/2" 13' - 0 1/4" 10' - 8"

4 1/2"
12' - 8 1/2" 9' - 7" 4' - 1 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 4" 12' - 6 1/2" 13' - 1" 13' - 4 1/2" 13' - 1 1/2" 12' - 2 1/2" 10 1/2" 13' - 1" 3' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/2" 8' - 9" 9' - 9 1/2"

N 252' - 9 1/4"

1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 CURRENT ISSUE:
A-600

ISSUE FOR PERMIT


1  2ND FLOOR 
A-101 3/32" = 1'-0"
CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
CHECKED BY:
BASE4 NOTES
LA/RB
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE PROJECT #:
NOTED B4-250-2101
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE. SHEET NAME:
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
2ND FLOOR
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF PLAN
GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. SHEET NUMBER:
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION

A-101
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS

0" 1"
1 2 3 4 5 1 6 7 8 A-602
9 10 11 12 13 14 15 16 17 18 19 2 20 21 22 23 24 25 2 26
A-604 A-601 A-603

252' - 9 1/4"
2901 Clint Moore Rd, #114
4 1/2" 1' - 1 1/2" Boca Raton, FL 33496
12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 10 3/4" 13' - 1" 3' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4" 888.901.8008 www.base-4.com
ARCHITECT:
6' - 9 1/8" 13' - 0 3/8" 13' - 0 7/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 1/2" 6' - 9 1/4" 5' - 9 3/8" 14' - 1 3/8" 5' - 9 3/4" 6' - 9" 13' - 2 1/2" 13' - 0" 13' - 2" 13' - 0" 13' - 2" 13' - 0" 17' - 11 1/2" 18' - 9 3/4"
Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

A A
A-405 A-401

LINEN ER-6.1
CHUTE

6' - 0" 4' - 9 3/4"


N N
4' - 9 3/4"

6' - 0" 4' - 9 3/4"


6' - 0"

ER-6.2 W1 W1 W1 W1 W1 W1 W1 ER-6.1 IR-6.1 ER-6.1


M M

3' - 10 1/4"
GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 ELEC/PBX
HOUSEKEEPING
342 11/30/2022
2022-12-018:26:01 PM
20:03:53
3' - 10 1/4"

ER-6.1 W1 W1 W1 W1 W1 W1 ER-6.1 W1 W1 ER-6.1 ER-6.1 341 FR-4.1


L L OWNER:
GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 342
ST-6.1 ELECTRIC
W1 ER-6.1 W1 GD-6.1 EL-6.1
IP-4.1 CHASE
K EL-6.1 K
341

1' - 4 3/4"
1' - 4 3/4"

KING ONE
ST-6.2
FR-4.1

43' - 6 3/8"
J BEDROOM J
KING STUDIO QUEEN QUEEN QUEEN QUEEN 3
ER-6.1 KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO SUITE QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN
17' - 4 1/2"

17' - 4 1/2"
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE ACC(TUB) STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE A-320
SUITE CONN. GD-6.1 EL-6.1
32' - 8 5/8"

301 303 305 307 309 311 313 315 317 IP-4.1 321 323 325 327 329 331 333
2 10655 N.E. 4th Street, Suite 606 |
A-602 ELEVATOR
LOBBY UP Bellevue, WA 98004
IP-6.1 STAIR#1
H IF-6.1 340 395 H
3' - 4 1/4"

3' - 4 1/4"
[email protected]
FR-4.1 ICE ERV
G EL-6.1 SHAFT G P:(425) 598-8516
343
PROJECT INFORMATION:
IR-6.1 CR-6.2 ER-6.1
F 340
F
3' - 11 1/2"

3' - 11 1/2"
5' - 8 1/2"

5' - 8 1/2"
2
CLEAR

CLEAR
CR-6.1
5' - 0"

5' - 0"
CR-6.1 ERV CORRIDOR CR-6.1 CR-6.1
A-604 W2 SHAFT W2
ST-6.1 CR-6.1 300 CR-6.1
396 344
E
12' - 8 5/8"

83' - 2"
E ER-6.1 ST-6.1
9' - 10 1/2"

9' - 10 1/2"
83' - 2"

DN
ST-6.2 STAIR#2 1 A-603
A-601 1 STORAGE
396 IR-6.1
UP ST-6.1 344
3 MEDFORD, OR
D A-321 D
ST-6.3 IP-4.1
IP-4.1 QUEEN QUEEN

39' - 6 5/8"
ER-6.1 KING ONE QUEEN QUEEN STUDIO SUITE- Prototype Version 3.0
BEDROOM KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN STUDIO SUITE ACC.
20' - 0 3/4"
20' - 0 3/4"

20' - 0 3/4"
SUITE SUITE SUITE SUITE SUITE SUITE CONN. SUITE CONN. STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE CONN. CONN.(TUB)
August 2022
306 308 310 312 314 316 318 320 322 324 326 328 330 332 334 336 338 ISSUE
2 DELTA ISSUE DATE DESCRIPTION
NO.
A-600
IP-4.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 GD-6.1
GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 1 A1 2022.11.30 ISSUED FOR
GD-6.1
PERMIT
C C
5' - 11 1/4"
5' - 11 1/4"

10" 5' - 11 1/4"


ER-6.1 W1 W1 W1 W1 W1 W1 W1 ER-6.1 W1
ER-6.1
ER-6.1
B B
10"

W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 ER-6.2
ER-6.1 ER-6.1
A A
A
A-403

12' - 8 1/4" 6' - 5 5/8" 12' - 7" 14' - 1 1/8" 13' - 0 3/4" 13' - 2" 12' - 11 1/2" 13' - 2 1/8" 13' - 0 1/2" 6' - 3 7/8" 6' - 8" 13' - 3" 12' - 11" 13' - 4 1/2" 12' - 10" 13' - 4" 12' - 10" 13' - 3" 6' - 3" 6' - 9" 13' - 0 1/4" 10' - 8"

10 3/4" 3' - 1" 4 1/2" 1' - 1 1/2"


12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 13' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4"
252' - 9 1/4"

1
CURRENT ISSUE:
A-600

ISSUE FOR PERMIT


1  3RD FLOOR 
A-102 3/32" = 1'-0" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
CHECKED BY:
BASE4 NOTES
LA/RB
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE PROJECT #:
NOTED B4-250-2101
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE. SHEET NAME:
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
3RD FLOOR
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF PLAN
GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. SHEET NUMBER:
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION

A-102
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS

0" 1"
1 2 3 4 5 6 7 8 A-602
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

1 2 2
1
A-604 A-601 A-603

252' - 9 1/4"

3' - 1" 4 1/2" 1' - 1 1/2" 2901 Clint Moore Rd, #114
12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 10 3/4" 13' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4" Boca Raton, FL 33496
888.901.8008 www.base-4.com
5' - 9 3/8"
6' - 9 1/8" 13' - 0 3/8" 13' - 0 7/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 3/8" 13' - 1 1/8" 13' - 0 1/2" 6' - 9 1/4" 14' - 1 3/8" 5' - 9 3/4" 6' - 9" 13' - 2 1/2" 13' - 0" 13' - 2" 13' - 0" 13' - 2" 13' - 0" 17' - 11 1/2" 18' - 9 3/4" ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

LINEN
CHUTE ER-6.1
6' - 0" 4' - 9 3/4"

N N

6' - 0" 4' - 9 3/4"


4' - 9 3/4"

ER-6.2
W1 W1 W1 W1 W1 W1 W1 ER-6.1 IR-6.1 ER-6.1
3' - 10 1/4"

M M

3' - 10 1/4"
ER-6.1 ER-6.1 ER-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1GD-6.1 SC-02
HOUSEKEEPING ELEC/PBX
6' - 0"

ER-6.1 W1 W1 W1 W1 W1 W1 W1 W1 FR-4.1 11/30/2022


2022-12-018:26:01 PM
20:04:01
ERV 441 442
L SHAFT L OWNER:
GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 EL-6.1 442 ST-6.1 ELECTRIC
W1 ER-6.1 W1GD-6.1
CHASE
K 441
K
1' - 4 3/4"

EL-6.1 ST-6.2

1' - 4 3/4"
IF-6.1 KING ONE IP-4.1
J BEDROOM
FR-4.1 J
KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO SUITE QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN
17' - 4 1/2"

17' - 4 1/2"
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE SUITE CONN. ACC(TUB) STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE
4
32' - 8 5/8"

401 403 405 407 409 411 413 415 417 421 423 425 427 429 431 433 EL-6.1
2 A-320
ELEVATOR
10655 N.E. 4th Street, Suite 606 |
DN

3' - 4 1/4"
A-602 Bellevue, WA 98004
ER-6.1 LOBBY
STAIR#2 H
440
H 495
3' - 4 1/4"

[email protected]
FR-4.1 ICE EL-6.1 ERV G P:(425) 598-8516
G SHAFT
443
ER-6.1 F PROJECT INFORMATION:
IR-6.1

83' - 1"

3' - 11 1/2"
440
3' - 11 1/2"
5' - 8 1/2"

5' - 8 1/2"
2
CLEAR

CLEAR

83' - 2"
CORRIDOR
5' - 0"

5' - 0"
CR-6.1 ERV CR-6.1 ERV CR-6.1 CR-6.2 FR-4.1
A-604 W2 SHAFT W2 E
ST-6.1 CR-6.1 CR-6.1 SHAFT 400 CR-6.1
496 444
12' - 8 5/8"

F ST-6.1
9' - 10 1/2"

DN
83' - 2"

STAIR#1
ST-6.2 1 A-603
E A-601 1 496 STORAGE
IR-6.1
ST-6.1 444
4 MEDFORD, OR
D A-321 D
ST-6.3

29' - 11 1/4"
KING ONE QUEEN QUEEN KING SUITE
BEDROOM KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN STUDIO SUITE ACC.
SUITE SUITE SUITE SUITE SUITE CONN. SUITE CONN. STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE CONN.(TUB)
Prototype Version 3.0
SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE STUDIO SUITE CONN. A
20' - 0 3/4"
20' - 0 3/4"

ER-6.1
406 410 412 414 416 418 420 422 430 434 438 A-400
August 2022
408 424 426 428 432 436
ISSUE
2 DELTA ISSUE DATE DESCRIPTION
NO.
A-600
1 A1 2022.11.30 ISSUED FOR
IF-6.1 GD-6.1 IF-6.1 GD-6.1 IF-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 GD-6.1 ER-6.1 PERMIT
C C
5' - 11 1/4"
10" 5' - 11 1/4"

10" 5' - 11 1/4"


ER-6.1 W1 W1 W1 W1 W1 W1 W1 ER-6.1 W1 ER-6.1

B B
W1 W1 W1 W1 W1 W1 W1 W1 W1 W1
ER-6.2
A ER-6.1 ER-6.1 A
A
A-407

12' - 8 1/4" 6' - 5 5/8" 12' - 7" 14' - 1 1/8" 13' - 0 3/4" 13' - 2" 12' - 11 1/2" 13' - 2 1/8" 13' - 0 1/2" 6' - 3 7/8" 6' - 8" 13' - 3" 12' - 11" 13' - 4 1/2" 12' - 10" 13' - 4" 12' - 10" 13' - 3" 6' - 8 1/2" 6' - 3 1/2" 13' - 0 1/4" 10' - 8"
4 1/2" 1' - 1 1/2"
12' - 8 1/4" 9' - 7" 4' - 1 1/4" 13' - 0 3/4" 13' - 0 1/2" 13' - 1" 13' - 0 1/2" 13' - 1" 13' - 3 3/4" 12' - 6 1/2" 13' - 1" 13' - 4 1/4" 13' - 1 1/2" 12' - 2 1/4" 10 3/4" 13' - 1" 3' - 1" 10' - 0" 13' - 1" 13' - 1" 11' - 4 1/4" 7' - 7 1/2" 9' - 9 1/4"

252' - 9 1/4"
N

1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 CURRENT ISSUE:
A-600

ISSUE FOR PERMIT


1  4TH FLOOR 
A-103 3/32" = 1'-0"
CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
CHECKED BY:
BASE4 NOTES
LA/RB
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE PROJECT #:
NOTED B4-250-2101
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE. SHEET NAME:
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
4TH FLOOR
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF PLAN
GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. SHEET NUMBER:
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION

A-103
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS

0" 1"
GENERAL NOTES : BATHROOM NOTES: x PUBLIC FURNISHINGS LEGEND KEYNOTES-GUESTROOM RESTROOMS
PA-100 BANQUETTE 300 SHELVING
• BASE4 INTERIORS HAS PERFORMED THE WORK AND PRODUCED THE INTERIOR • REFER TO ENGINEERING DOCUMENTATION FOR ALL PLUMBING
PA-101-03 PILLOW 301 OFFICE FURNITURE
TAG DESCRIPTION
CONTRACT DOCUMENTS IN ASSOCIATION WITH BASE4 ARCHITECTS & ENGINEERS. SPECIFICATIONS, DRAINS, VENTS, ETC.
PA-104-06 LOUNGE CHAIR 302 WORK STATION 1 WALL MOUNTED GRAB BARS W/ REQUIRED CLEARANCES - 12" ABOVE AND1-1/2"
• REFER TO ARCHITECTURAL COVER SHEET FOR ADDITIONAL GENERAL NOTES & • CONTRACTOR TO PROVIDE FIXTURE AND ACCESSORY CUT SHEETS TO BASE4
PA-107 PILLOW 303 SAFE BELOW. REFER TO ACCESSIBILITY STANDARDS & HADG.
REQUIREMENTS. INTERIORS FOR APPROVAL PRIOR TO ORDERING.
• CONTRACTOR TO ENSURE CONCRETE FLOOR SLABS ARE LEVEL AND SUITABLY • CONTRACTOR TO PROVIDE PHYSICAL TOILET PARTITION FINISH SAMPLES TO PA-108 COUNTER STOOL 304 LOCKER 2 VANITY MIRROR AND LIGHT FIXTURE
PREPARED FOR INSTALLATION OF NEW FLOORING MATERIALS. BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING. PA-109 LOUNGE CHAIR 400 FIRE PIT WITH FITTED SCREEN 3 TOILET
• CONTRACTOR TO CONDUCT A MOISTURE PERMEATION TEST ON ALL CONCRETE • CONTRACTOR TO INSTALL MOISTURE RESISTANT GWB OR BACKER BOARD AT PA-110-12 DINING CHAIR 401 COMMERCIAL WASHER 5 FRAMING SUBCONTRACTOR TO RPOVIDE3/4" F.R.T. PLYWOOD BLOCKING TO
SLABS ON GRADE PRIOR TO THE INSTALLATION OF ANY AND ALL FLOORING ALL WET WALL LOCATIONS (I.E. WALLS AT SINKS, TOILETS, SHOWERS, ETC. PA -113 OTTOMAN 402 COMMERCIAL DRYER RECEIVE ITEM INDICATED-EXTEND FULL LENGTH OF OBJECT 2901 Clint Moore Rd, #114
MATERIALS. TEST IS TO DETERMINE THE AMOUNT OF MOISTURE PASSING UP • CONTRACTOR TO PROVIDE BLOCKING IN WALLS BABY CHANGING STATIONS, PA-114-16 COUNTER STOOL 403 WORK CENTER
PA-117 TASK CHAIR 404 WALL SHELVING 6 SHOWER SURROUND-REFER TO EQUIPMENT SCHEDULE Boca Raton, FL 33496
THROUGH THE SLAB. CONTRACTOR TO NOTIFY BASE4 OF ANY ISSUES PRIOR TO GRAB BAR LOCATIONS, AND SHOWER BENCH SEATS AS REQUIRED.
THE INSTALLATION OF FLOORING MATERIAL. ALL MANUFACTURER’S • CONTRACTOR TO PROVIDE AND INSTALL FULL STEEL LADDER FRAMES AS PA-118 BENCH 405 BREAKROOM SINK 13 FLOOR DRAIN 888.901.8008 www.base-4.com
RECOMMENDED INSTALLATION REQUIREMENTS ARE TO BE MET. REQUIRED UNDER ALL STONE COUNTERS FOR SUPPORT. ADD ADDITIONAL PA-119 WOOD ARM CHAIR 406 COIN OPERATED WASHER
PA-120-21 PILLOW 407 COIN OPERATED DRYER ARCHITECT:
• ALL PREFINISHED MATERIALS SHALL BE PROTECTED FROM DAMAGE OR STEEL AND WOOD BLOCKING IN PARTITIONS BEYOND AS REQUIRED. UNLESS
REPAIRED/REPLACED AT CONTRACTOR’S EXPENSE. CALLED FOR IN COUNTER DETAILS, NO VERTICAL LEGS ARE TO BE USED. PA-200 PENDANT 408 DECORATIVE TRASH CAN
• ALL FIELD FINISH METAL WORK SHALL BE DONE IN ACCORDANCE WITH THE • COUNTERS TO BE SCRIBED TO ADJACENT WALLS ON ALL SIDES. PA-201 SMALL PENDANT 409 DISHWASHER Ricardo J. Muniz-Guillet, AIA
PAINTING SPECIFICATIONS. • PAINT ALL EXPOSED BLOCKING TO MATCH WALL BEYOND, UNLESS NOTED PA-202
PA-203
TABLE LAMP
CEILING LIGHT
410
411
MOBILE TABLE
REACH-IN COOLER
KEYNOTES GUESTROOMS 2030 Habersham Trce
OTHERWISE. Cumming, GA 30041
• INSULATE ALL EXPOSED PIPES BELOW COUNTER PER ADA REQUIREMENTS, PA-204 WALL SCONCE 412 REACH-IN FREEZER TAG DESCRIPTION
PA-205 FLOOR LAMP 413 WORK STATION 954.812.6650
USING TRUEBRO-LAV GUARD OR EQUAL; PROVIDE COLOR OPTIONS TO BASE4 1 PTAC UNIT
INTERIOR FINISH NOTES: INTERIORS FOR APPROVAL PRIOR TO ORDERING. PA-300
PA-301
BREAKFAST SERVING COUNTER
BUSSING STATION
414
415
MOBILE SHELVING
COFFEE MACHINE 3 IN BATHROOM LOCATIONS ONLY, LIGHT SWITCH EQUIPPED WITH NIGHTLIGH. MOUNTED SO TOP OF SWITCH IS 48" MAX A.F.F
[email protected]
• CONTRACTOR TO PROVIDE PRODUCT DATA SUBMITTALS ON ALL TOILET
PA-302 MEDIA WALL & COFFEE BAR 416 3-COMPARTMENT SINK 4 MANUAL BLACK OUT ROLLER SHADE TO EXTEND 6'' BEYOND WINDOW OPENING; SHEER ROLLER SHADE TO BE MOUNTED INSIDE WINDOW OPENING
• ALL CONDITIONS AND DIMENSIONS ON THE DRAWINGS AND AT THE PROJECT SITE ACCESSORIES SPECIFIED. INSTALL TOILET AND BATH ACCESSORIES IN
ARE TO BE FIELD VERIFIED PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH ACCORDANCE WITH ADA REQUIREMENTS. PA-303 DISH RECOVERY 417 HAND SINK 5 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR
WORK. PA-304 HOME 2 MARKET 418 RACK/SHELF 7 PRE-MANUFACTURED SHOWER PAN
• SAMPLES OF ALL SPECIFIED FINISHES ARE TO BE SUBMITTED TO BASE4 FOR FINAL PA-305 FRONT DESK 419 PRE-RINSE WITH FAUCET 8 CEILING MOUNTED DRAPERY ROD--PROVIDE BLOCKING AS REQ'D
APPROVAL PRIOR TO ORDERING AND INSTALLING. PA-306 BUSINESS CENTER 420 WATER FILTER
9 ALTERNATE LOCATION OF DOOR FOR CONNECTING ROOMS TO ACCESSIBLE ROOMS--REFER TO OVERALL PLANS FOR LOCATION OF ACCESSIBLE ROOMS
PA-307 WINDOW PERCH 421 WALL MOUNTED SHELVING
• ALL SURFACES RECEIVING NEW FINISHES SHALL BE PROPERLY PREPARED PER
THE MATERIAL MANUFACTURER’S RECOMMENDATION. NOTIFY BASE4 OF ANY
MILLWORK/ CASEWORK: PA-308 PERCH 422 UNDER COUNTER REFRIGERATOR 10 DEDICATED CIRCUIT FOR DISHWASHER
DEFECT WHICH COULD AFFECT INSTALLATION OF ANY FINISH MATERIAL. PA-309-10 SERVING COUNTER BOARD ROOM & MEETING ROOM 423 UPPER CABINETS 11 RANGETOP STYLE MICROWAVE AFFIXED TO WALL
• MILLWORK SUBCONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF PA-400-02 ROLLER SHADE 424 BATTERMIX STARTER KIT 12 FULL HEIGHT MIRROR
• ALL SEALANTS AND ADHESIVES USED IN CONSTRUCTION TO HAVE VOC CONTENTS
ALL PROJECT AREAS AND DELIVERY PATH MEASUREMENTS/DIMENSIONS AND PA-403 DRAPERY PANELS 425 CONVEYOR OVEN
MEETING WITH OR LOWER THAN THE CONTENT LIMITS IN THE SOUTH COAST AIR 13 BEGIN CARPET TILE THIS SIDE W/ FULL TILE--FIRST TWO ROWS OF TILE
FIELD CONDITIONS PRIOR TO THE START OF FABRICATION AND GENERAL PA-404 ROMAN SHADE 426 JUICE DISPENSER
QUALITY MANAGEMENT DISTRICT RULE #1166. TO BE INSTALLED AROUND BUILT-IN CASEGOODS
COORDINATION WITH OTHER TRADES AS REQUIRED. PA-405 ROLLER SHADE 427 REFRIGERATOR
• CONTRACTOR IS TO COMPLY WITH FIRE DEPT. REGULATIONS & OSHA 14 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TO HADG FOR ACCESSIBLE ROOM REQ'S.
• CONTRACTOR TO ENSURE THAT THE FIELD CONDITIONS IN THE PA-500-06 ARTWORK 428 WAFFLE IRON
REGULATIONS REGARDING USE AND DISPOSAL OF FLAMMABLE/HAZARDOUS 15 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
CONSTRUCTION AREA ARE SUITABLE FOR RECEIVING/INSTALL OF ANY AND PA-507 MIRROR 429 MERCHANDISER REFRIGERATOR
MATERIALS.
ALL MILLWORK/CASEWORK. THE APPROXIMATE RANGES ARE RECOMMENDED: PA-600 TOWEL HAMPER 430 MERCHANDISER FREEZER 17 DEVICE SHOWN THIS LOCATION ON PLAN FOR CLARITY --REFER TO ELEVATIONS FOR EXACT POSITION
• BASE4 CANNOT GUARANTEE WARRANTY OR BE HELD RESPONSIBLE FOR A
OPTIMUM MOISTURE CONTENT OF WOOD: 5-10%, INDOOR RELATIVE HUMIDITY PA-602 UTILITY CART 431 WALL MOUNTED TELEVISION 18 RECESSED CEILING LIGHT FOR WET LOCATIONS W/ SHATTER PROOF LENS
PRODUCT’S OR MANUFACTURER’S FAILURE, OR IT’S INABILITY TO SATISFY ITS
REQUIRED TO HOLD OPTIMUM MOISTURE CONTENT: 25-55% (TEMP. AND OF-603-05 PLANTER 432 ICE DISPENSER
OBLIGATIONS. 19 TOILET EXHAUST GRILLE
HUMIDITY AFFECTS WOOD PRODUCTS). GC TO REFER TO MOST RECENT AWI OF-700 BENCH 433 WARMING KETTLE 11/30/2022 8:26:01PM
22/11/30 9:29:50 PM
• ALL INTERIORS PRODUCTS INCLUDING BUILDING MATERIALS, FINISHES AND 21 OUTLINE OF SOFA
TEMPERATURE AND HUMIDITY CHART TO VERIFY CONDITIONS ARE SUITABLE. OF-701 LOUNGE CHAIR 434 WAFFLE IRON - FUTURE
FURNITURE PRODUCTS SPECIFIED FOR THE PROJECT ARE TO FALL BELOW 22 APPROXIMATE LOCATIONS OF MILLWORK SUPPORTS ON FLOOR.PROVIDE SHIMS OR LEVELERS UNDER SUPPORTS TO PREVENT CARPET CRUSHING
• DELIVERY OF ALL MILLWORK TO THE PROJECT AREA (ELEVATOR AND/OR OF-702 BENCH 435 CONVECTION OVEN OWNER:
ACCEPTABLE CONTAMINANT LEVELS AS OUTLINED IN ‘MSDS’.
STAIRS) IS TO BE COORDINATED WITH THE GENERAL CONTRACTOR. ALL OF-703 OTTOMAN 436 WARMING DISPLAY CABINET 24 WIRED THERMOSTAT FOR PTAC. MOUNTED 48" MAX TO TOP OF DEVICE.COMMUNICATION BETWEEN THERMOSTAT AND PTAC MAY BE WIRELESS
• FLOORING INSTALLATION MUST COMPLY WITH MFR’S RECOMMENDED
MILLWORK IS TO BE CONSTRUCTED IN SECTIONS AS REQUIRED IN ORDER TO OF-704 CUBE TABLE 800 TOWEL HAMPER 25 EXTEND J-BOX, DEVICE & COVER PLATE FLUSH W/ MILLWORK BACK PANEL
INSTALLATION INSTRUCTIONS TO MAINTAIN DIRECTION OF PATTERN, TEXTURE,
BE DELIVERED AND INSTALLED AS EFFICIENTLY AS POSSIBLE AT THE SITE. OF-705 C-TABLE 801 WATER & CUP DISPENSER
NAP, AND PILE AT ALL SEAMED LOCATIONS. 28 DOORBELL ON/OFF SWITCH (COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE AS REQ'D.
• FULL DETAILED SHOP DRAWINGS ARE TO BE SUBMITTED TO BASE4 INTERIORS OF-706 SIDE TABLE 802 GYM WIPES DISPENSER
• ALL FLOORING MATERIALS SHALL BE INSTALLED ON A CLEAN AND SMOOTH 29 START TILE @ DOOR W/ ONE ROW OF FULL TILES
AND SHOULD INCLUDE DIMENSIONED PLANS/ELEVATIONS, ATTACHMENT OF-707 SIDE TABLE 803 TREADMILL
SUBSTRATE, AS PER MANUFACTURER SPECIFICATIONS/RECOMMENDATIONS. 30 EDGE OF PTAC ABOVE CARPET TILES
DEVICES, BLOCKING & SHIMMING REQUIRED OF-708 4-TOP TABLE 804 FITNESS TRAINER ELLIPTICAL
• STANDARD SEAMLESS BROADLOOM & SHEET GOOD WIDTHS SHALL BE USED AND
• ALL CASEWORK AND FINISHES ARE TO CONFORM WITH THE “ARCHITECTURAL OF-712 DINING CHAIR 805 RECUMBENT CYCLE 31 MIN. CEILING HEIGHT MUST BE MAINTAINED -- REFER TO HOME 2 SUITES BY HILTON STANDARDS MANUAL
SEAMS KEPT TO A PRACTICAL MINIMUM. INSTALLER SHALL PROVIDE A SEAMING
WOODWORK QUALITY STANDARDS” OF THE ARCHITECTURAL WOODWORK OF-722 ENTRY BENCH 806 FREE WEIGHTS & RACK 32 32.FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T. PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED - EXTEND FULL LENGTH OF OBJECT
DIAGRAM IN THE FORM OF SHOP DRAWINGS TO BASE4 FOR APPROVAL PRIOR TO
INSTITUTE (AWI), LATEST EDITION.
ORDERING AND INSTALLING.
• ALL PLASTIC LAMINATES OR FINISH MATERIALS WITH A GRAIN/PATTERN
PA-800-01 ROUND TABLE 807 WEIGHT BENCH 33 GENERAL CONTRACTOR TO COORDINATE W/ FIXTURE FABRICATOR WHERE NECESSARY TO PROVIDE PROPER BLOCKING IN WALL FOR ITEM KEYNOTED. 10655 N.E. 4th Street, Suite 606 |
• UNLESS OTHERWISE NOTED, FLOORING MATERIALS THAT TRANSITION AT PA-802 RECTANGULAR TABLE 808 STRENGTH SYSTEM
AND/OR TEXTURE IS TO BE INSTALLED SO THAT THE GRAIN/PATTERN AND/OR PA-803 HALF ROUND TABLE 809 MEDICINE BALLS & RACK
35 SWITCHES CONTROLLING MECHANICAL SHADES - REFER TO FFE MANUAL Bellevue, WA 98004
DOORWAYS SHALL BE SEAMED TO FALL HALF WAY UNDER CLOSED DOOR AND ARE 36 OUTLET ABOVE FOR MICROWAVE - REFER TO ROOM ELEVATION MOUNT DEVICE HORIZONTALLY--FACE PLATE TO BE WHITE
TEXTURE IS CONTINUOUS ACROSS ALL SURFACES FOR A UNIFORM PA-804 BREAKFAST TABLE 810 EXERCISE BALL
TO BE INVISIBLE WHEN DOOR IS CLOSED.
INSTALLATION. REFER TO DRAWINGS FOR SPECIFIC DIRECTIONS. PA-805 LOG SIDE TABLE 811 EXERCISE MAT 37 REQ'D ACCESSIBLE CLEAR FLOOR AREA DESIGNATION
• ALL BROADLOOM CARPET AND SHEET GOODS TO BE INSTALLED AS DIRECT GLUE
• THE CONTRACTOR SHALL COORDINATE THE SCOPE OF MILLWORK WITH ALL 38 INDICATES DIRECTION OF CARPET PATTERN
[email protected]
DOWN METHOD UNLESS OTHERWISE NOTED. PA-806-07 SIDE TABLE 812 RULES SIGN
• CONTRACTOR SHALL ENSURE WITH THE INSTALLER/DEALER MATCHING DYE LOTS
PROJECT ELECTRICAL, COMMUNICATIONS, PLUMBING, LIGHTING FIXTURES PA-808 CONSOLE TABLE 813 WALL MOUNTED TELEVISION 39 CENTER ARTWORK OVER SOFA P:(425) 598-8516
AND DEVICE LOCATIONS. THE CONTRACTOR SHALL COORDINATE AND BE PA-809 ADIRONDACK CHAIR 814 EMERGENCY TELEPHONE
OF ALL FLOORING MATERIALS ARE IN THE SAME PATTERN AND COLOR. 40 COUNTERTOP MICROWAVE PROJECT INFORMATION:
RESPONSIBLE FOR CUTOUTS AND TEMPLATES SUPPLIED BY OTHER TRADES. PA-810 TOWEL AND FOLDING STATION 816 TOWEL HOOK
• CARPET BASE SHALL HAVE EDGE BINDING TO MATCH CARPET COLOR. 41 GRAPHIC ART. REFER TO ACCESSORIES LEGEND & CONSTRUCTION PLAN
• ELECTRICAL WORK SPECIFIED IN CONJUNCTION WITH MILLWORK IS TO BE UL PA-811 SIDE TABLE 817 WALL MOUNTED MIRROR
CONTRACTOR TO PROVIDE BINDING SAMPLE TO BASE4 FOR APPROVAL PRIOR TO 44 WAP IN 3-GANG BOX MOUNTED VERTICALLY UNDER DESK. MAINTAIN 6" BETWEEN ALL BOXES, TYP ALL GUESTROOMS. COORDINATE WAP LOCATION WITH
APPROVED AND PROVIDED BY ELECTRICAL CONTRACTOR. MILLWORK BOH-812 BREAKROOM TABLE 819 WALL MOUNTED CLOCK
FABRICATION. REFER TO PLANS FOR INSTALLATION LOCATIONS. CASEGOODS TO AVOID CONFLICTS. VISIT CONNECTEDROOM.HILTON.COM FOR CURRENT WIRELESS INTERNET REQ'S AND LIST OF APPROVED
CONTRACTOR TO COORDINATE INSTALLATION. BOH-813 BREAKROOM CHAIR 820 HYDRATION STATION
• MODULAR CARPET TO BE INSTALLED BY FULL SPREAD APPLICATION WITH INTEGRATORS.
• CONTRACTOR IS RESPONSIBLE FOR PROVING WOOD BLOCKING AND/OR
RELEASABLE ADHESIVE OR PER MANUFACTURER’S INSTALLATION GUIDELINES.
SUPPORT METAL IN PARTITIONS BEYOND MILLWORK AS REQUIRED FOR 45 EACH CABLE MUST HOMERUN BETWEEN THE GUESTROOM AND THE IDF ON EACH FLOOR
• PROVIDE AND INSTALL REDUCER STRIPS AND/OR APPROPRIATE FLOORING
SECURE ANCHORING OF MILLWORK. ALL VISIBLE BLOCKING TO BE PAINTED TO 46 OPTION WIRED DATA CONNECTION FOR GUEST USE: A) ADD CAT6 RJ-45 CABLE JACK AND PATCH CORD THROUGH DESKTOP GROMMET - OR - B) PATCH
TRANSITION ACCESSORIES WHERE CHANGE IN FLOORING HEIGHTS OCCUR.
MATCH SURROUNDING WALLS. CORD FROM WAP PORT THROUGH DESKTOP GROMMET.
• ALL CERAMIC/GRANITE/MARBLE/PORCELAIN TILES TO BE INSTALLED PER
MANUFACTURER’S RECOMMENDED INSTRUCTIONS FOR A THIN-SET INSTALLATION.
• ALL COUNTERTOP AND BACKSPLASH SEAMS ARE TO ALIGN WITH ONE x GR FURNISHINGS LEGEND 47 TV CONNECTIONS FOR FREE-TO-GUEST CONTENT: A) NO SMART TV: COAX CABLE BEHIND TV. CAT6 RJ-45 JACK BEHIND TV, RUN IN SMURF TUBE IN WALL
ANOTHER. ALL SEAMS ARE TO BE EQUALLY SPACED ALONG COUNTERTOP
CONTRACTOR IS TO FIELD VERIFY CONDITION OF NEW FLOOR PRIOR TO GR-101 SLEEPER SOFA GR-400 MANUAL ROLLER SHADE TO WAP UNDER DESK. PATCH CORD TO EDGE CONTROLLER FOR CONNECTED ROOM. MIN. 6" CLEARANCE FROM WALL BOXES - OR - B) SMART
UNLESS OTHERWISE NOTED ON DRAWINGS. PROVIDE A MITERED
INSTALLATION FOR ANY PREP WORK REQUIRED. ALL CUTTING OF TILES TO BE
COUNTERTOP SEAM AT ALL 90 DEGREE COUNTERTOP INTERSECTIONS GR-102 DINING CHAIR GR-401 MOTORIZED ROLLER SHADE TV-INTERNET PROTOCOL TELEVISION (IPTV); COAX NOT REQ'D. CAT6 RJ-45 JACK BEHIND TV RUN IN SMURF TUBE IN WALL TO WAP UNDER DESK. PATCH MEDFORD, OR
DONE WITH A WET SAW. JOINTS TO BE KEPT TO A MINIMUM; 1/16” PREFERRED GR-104 TASK CHAIR GR-404 ROOM DIVIDER CORD TO EDGE CONTROLLER FOR CONNECTED ROOM. CAT6 RJ-45 JACK BEHIND TV IN ONE-BEDROOM TV. MIN. 6" CLEARANCE FROM WALL BOXES. VISIT
UNLESS OTHERWISE NOTED ON DRAWINGS. HILTONHDTV.COM FOR ADDITIONAL INFORMATION.
UNLESS NOTED OTHERWISE. GR-105 OTTOMAN GR-405-406 CLOSET DRAPERY
• ALL COUNTERTOP TO WALL OR BACKSPLASH JOINTS TO BE CONTINUOUSLY
• CONTRACTOR TO PROVIDE CLEAVAGE MEMBRANE, SLIP SHEET AND/OR CRACK GR-200 TABLE LAMP GR-500 ARTWORK AT SLEEPER SOFA 48 PROVIDE HINGE STOP AT DOOR
SEALED WITH A CLEAR SILICONE SEALANT.
SUPPRESSION SYSTEM AS REQUIRED FOR PROJECTS WITH TILE EXCEEDING 12”X
• WHEREVER COUNTERS ARE INSTALLED WITHOUT BACKSPLASH, GR-201 DESK LAMP GR-503 VANITY MIRROR 50 PROVIDE OUTLET FOR UNDERCABINET LIGHTING BY OTHERS
Prototype Version 3.0
12” OR WHEN FLOOR/SLAB MOVEMENT IS EXPECTED. CONTRACTOR AND GR-202 NIGHTSTAND SCONCE GR-504 FULL LENGTH MIRROR August 2022
CONTRACTOR IS TO PROVIDE CAULK OF AN APPROPRIATE MATCHING COLOR
INSTALLERS TO REFER TO THE TCA (TILE COUNCIL OF AMERICA) INSTALLATION GR-203 VANITY SCONCE GR-600 QUEEN MATTRESS SET
AS REQUIRED AT THE INTERSECTION OF COUNTER WITH WALL. PROVIDE
HANDBOOK AND APPROPRIATE ANSI SECTIONS FOR GUIDELINES AND GR-204 WALL HOOK SCONCE GR-600.1 QUEEN BOX SPRING COVER ISSUE
COLOR SAMPLE TO BASE4 FOR APPROVAL PRIOR TO INSTALLATION. DELTA ISSUE DATE DESCRIPTION
REQUIREMENTS. GR-205 FLOOR LAMP GR-601 KING MATTRESS SET
• ALL STONE FLOORS AND COUNTERTOPS TO BE SEALED AS PER MANUFACTURER’S
• CONTRACTOR IS TO PROVIDE BLOCKING, FRAMING AND/OR P.LAM VERTICAL
SUPPORT LEGS FOR ALL COUNTERS IN ORDER TO ACCOMMODATE 100 LBS GR-206 WALL SCONCE GR-601.1 KING BOX SPRING COVER KEYNOTE- PUBLIC AREA & BOH FURNITURE NO.
RECOMMENDATIONS, UNLESS NOTED OTHERWISE. GR-207 TABLE LAMP GR-602 QUEEN BED BASE
PER LINEAL FOOT. SUPPORT SPACING NOT TO EXCEED 48” ON CENTER, TYP.
• ALIGN CERAMIC/GRANITE/MARBLE/PORCELAIN TILE AND BASE GROUT LINES.
• ALL MILLWORK TO BE SCRIBED TO ADJACENT WALLS, CEILINGS AND/OR GR-208 NIGHTSTAND SCONCE (ADA) GR-602.ADA QUEEN ACCESSIBLE BED BASE TAG DESCRIPTION 1 A1 2022.11.30 ISSUED FOR
• INSTALLER TO APPLY GROUT SEALER (IF RECOMMENDED) AFTER SUFFICIENT GR-300 QUEEN HEADBOARD GR-603 KING BED BASE PERMIT
FLOORS. PROVIDE FILLER STRIPS/PIECES AS REQUIRED FOR A UNIFORM, 1 TRASH CAN, RECYCLING BIN, & ASH BIN
CURING TIME HAS ELAPSED AND ALL MOISTURE HAS EVAPORATED (GENERALLY 2-3 GR-301 KING HEADBOARD GR-603.ADA A KING ACCESSIBLE BED BASE 3 ROLLER SHADES
TIGHT INSTALLATION.
DAYS). REFER TO MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR GR-302 VANITY GR-606 ACCESSIBLE QUEEN BED SKIRT
• ALL WALL OR BASE CABINETS WITH INTERNAL SHELVING HAVING A SPAN 4 OFFICE FURNITURE BY OWNER AS REQ'D.
ADDITIONAL INFORMATION. GR-303 ACCESSIBLE VANITY GR-607 ACCESSIBLE KING BED SKIRT
GREATER THAN 36”W IS TO BE PROVIDED WITH ADDITIONAL CENTER 5 ACCESSIBLE TABLE, REFER TO FF&E SPECIFICATIONS
• AT COMPLETION OF CONSTRUCTION, CONTRACTOR TO VACUUM ALL CARPETS, GR-302-316 WORKING WALL 901 REFRIGERATOR
SUPPORTS AS REQUIRED.
CLEAN PRIOR TO PROVIDING (2) COATS OF SEALER WAX ON ALL VINYL GR-317 KING NIGHTSTAND 902 DISHWASHER 6 EMPLOYEE LOCKERS SHALL COMPLY W/ACCESSIBILITY STANDARDS FOR PERCENTAGE OF ACCESSIBLE STORAGE - REFER TO HILTON'S ACCESSIBILITY
• FIELD TOUCH-UP SHALL BE COMPLETED UPON INSTALLATION OF MILLWORK.
COMPOSITION TILE AND/OR SHEET FLOORING REQUIRING SEALANT. PROVIDE A GR-318 SOFA SIDE TABLE 903 TELEVISION DESIGN GUIDE FOR REQ'S.
THIS SHALL INCLUDE THE FILLING AND TOUCH-UP OF EXPOSED JOB MADE NAIL
FINAL DAMP MOP FINISH ON ALL HARD FLOORING SURFACES. GR-319 DINING TABLE 904 CLOCK/ RADIO 7 LAUNDRY CHUTE TERMINATION ROOM
OR SCREW HOLES, REFINISHING OF RAW SURFACES RESULTING FROM JOB
• ALL BLOCKING BELOW COUNTERS TO BE PAINTED TO MATCH WALL BEYOND. GR-322 DOUBLE QUEEN NIGHTSTAND 905 TELEPHONE 8 TRENCH DRAIN FOR WASHING MACHINES
FITTING AND REPAIR OF JOB INFLICTED SCRATCHED AND MARKS, ALONG WITH
• ALL PAINT SHALL BE APPLIED AS RECOMMENDED BY THE PAINT MANUFACTURERS 906 QUEEN MATTRESS & BOXSPRING
FINAL CLEANUP OF FINISHED SURFACES, HARDWARE AND INSTALLATION 9 CLOSET ROD & SHELF
FOR SPECIFIC PURPOSES. 907 KING MATTRESS & BOXSPRING
AREA. 10 ENTERTAINMENT WALL
• ALL WALLCOVERING, INCLUDING VINYL AND TEXTILE WALL COVERING, SHALL BE 908 TUB SHOWER CURTAIN
• THE INSTALLER IS TO PROVIDE A GENERAL CLEANUP IN AND AROUND ALL
INSTALLED IN ACCORDANCE WITH THE SPECIFIED MANUFACTURER’S 909 SHOWER CURTAIN 15 VANITY AND MIRROR (VANITY MUST NOT ENCROACH INTO CLEAR FLOOR SPACE FOR ACCESSIBLE TOILET)
INSTALLATION WORK INCLUDING REMOVING ALL TOOLS, SCRAP MATERIAL,
INSTRUCTIONS TO ASSURE COLOR UNIFORMITY/COLOR MATCH, AND TO MAINTAIN 16 LINEN CART STORAGE AREA
ETC.
PRODUCT WARRANTIES. 17 36" x 36" MOP SINK LOCATION
20 EXTERIOR LIGHT STRING -- REFER TO ELEVATIONS FOR BLOCKING
KEYNOTES- PUBLIC AREA ELEVATIONS 21 PRIMED AND PAINTED TUBE STEEL OPEN CANOPY AREA WITH STAINED METAL STUD TRELLIS INFILL -- SYSTEM TO BE UPLIGHTED BY SCONCES ON TUBE
STEEL STRUCTURE WITH SUPPLY POWER RUN IN CONCEALED CONDUIT
TAG DESCRIPTION 22 PRIMED AND PAINTED TUBE STEEL COVERED SECTION OF CANOPY
REFLECTED CEILING PLAN LEGEND CEILING FINISH LEGEND 1 GYPSUM BOARD SOFFIT FASCIA- REFER TO CEILING PLANS 23 ACCESSIBLE BASE CABINET WITH SINK
2 HVAC SUPPLY AIR DIFFUSER- CENTER IN FASCIA/ BULKHEAD PAINT TO MATCH WALL 39 TWO (2) COMPARTMENT SINK
FLUORESCENT LIGHT ACCESS PANEL
AP
LINEAR DIFFUSER TYPE 3 HVAC RETURN AIR DIFFUSER, PAINT TO MATCH WALL
(2'-0"x4'-0") (1'-0"x1'-0" UNO) MARK DESCRIPTION
FLUORESCENT LIGHT
(2'-0"x2'-0")
SMOKE DETECTORS SD
SUPPLY AIR DIFFUSER
A PRIMED & PAINTED GYPSUM BOARD
4 "SIGHTS & SOUNDS WALL" - REFER TO PUBLIC SPACE FF&E SPECIFICATIONS
SPECIFICATIONS KEYNOTE-ADA GUESTROOM RESTROOM
SPRINKLER HEADS B PRIMED & PAINTED GYPSUM BOARD-MOISTURE 5 OPTIONAL ATM LOCATION
DOWNLIGHT S WALL MOUNT SPR. RESISTANT
TAG DESCRIPTION
SPEAKERS 6 ROLLER SHADE -REFER TO FF&E
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM 3 TUB / SHOWER SURROUND - ACCESSIBLE SHOWER THRESHOLD.1/2" MAX HEIGHT BEVELED 1:2 MAX. REFER TO HADG FOR MORE INFORMATION.
SPRINKLER HEADS 7 PREPARE & PRIME WALL - REFER TO HOME 2 FOR GRAPHIC INSTALLATION
PENDANT LIGHT FIRE ALARM/HORN/STROBE F ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED 6 ACCESSIBLE VANITY UNIT, REFER TO FURNITURE DWGS. CURRENT ISSUE:
CEILING MOUNT 8 EMPLOYEE BREAK AREA - REFER TO FF&E SPECIFICATIONS
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE 7 ACCESSIBLE REMOVABLE TUB/SHOWER SEAT. REFER TO ACCESSIBILITY STANDARDS AND HADG FOR REQUIREMENTS
ACCESS PANEL ONLY-REFER TO SECTIONS 9 WALL ART - REFER TO FF&E SPECIFICATION - CENTER ART AS REQUIRED
WALL WASH LIGHT CEILING LIGHT 8 CLEAR AREA OF SINK/VANITY MUST BE ACCESSIBLE
(1'-0"x1'-0" UNO) AP 10 HOME 2 GUARANTEE SIGN LOCATION
STRIP LIGHTS
CEILING FAN
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE 11 BUSINESS CENTER - REFER TO FF&E SPECIFICATIONS
10
11
SHOWER HEAD
SHOWER DIVERTER VALVE
ISSUE FOR PERMIT
(RACK & HEADBOARDS) OCCUPANCY SENSOR
OS F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED & 12 BREAKFAST COUNTER - REFER TO FF&E SPECIFICATIONS
COMBINATION OF SMOKE 12 HAND SHOWER AND SIDE BAR. HAND-HELD SHOWER UNIT REQUIRED TO HAVE ON/OFF CONTROL WITH NON-POSITIVE SHUT OFF.
WALL MOUNT LIGHT CS DOOR BELL AUDIO PAINTED 13 PROVIDE BLOCKING AS REQUIRED
AND CO DETECTOR 13 VANITY MIRROR AND LIGHT FIXTURE
VISUAL UNIT DB H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" 14 ELEVATOR AND SURROUND --FINISH TO BE BRUSHED STAINLESS STEEL CURRENT ISSUE DATE:
RETURN/EXHAUST 15 ON/OFF - PRESSURE BALANCING VALVE
EXIT LIGHT CLG. GRID SUSPENDED FROM STRUCTURE 15 STOREFRONT DOORS AND FRAMES TO MATCH EXTERIOR COLOR AND FINISH
GRILLE
J PRIME AND PAINTED EXTERIOR GYPSUM BOARD
18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR 2022.11.30
16 ACCESSIBLE POWER AND DATA INSTALLED AT EACH BUSINESS CENTER WORK STATION
19 TOILET DRAWN BY:
17 WALL MOUNTED TELEVISION
23 LEVER REQUIRED ON THE SIDE OF TANK OPPOSITE INSIDE CORNER OF WALL.
A CEILING FINISH 18 ALL SELF SERVICE DISPENSERS AND OTHER AMENITIES MUST BE LOCATED WITHIN 48" AFF REACH HEIGHT. IF ITEMS PJ/RG
25 SHOWER SURROUND
9'-6" CEILING HEIGHT ARE DEEPER THAN 10" FROM THE FRONT OF THE BASE CABINET, PROVIDE DISPENSERS AT 46" MAX AFF.
CHECKED BY:
19 FIRE EXTINGUISHER CABINET

-
FINISH LEGEND
20
21
FITNESS ROOM RULES SIGN
LINEN CHUTE DISCHARGE DOOR
KEYNOTE FINISH-PUBLIC AREA LA/RB
CEILING DIMENSION LEGEND PT PAINT 22 WATER BOTTLE FILLER - 48" A.F.F. TO HIGHEST OPERABLE PART TAG DESCRIPTION
PROJECT #:

PL PLASTIC LAMINATE 23 HOUSE PHONE 1 RECESSED GRILL MAT (BASIS OF DESIGN) - MANUFACTURER - AMERICAN FLOOR MATS - STYLE - 7/16" RECESSED GRILLE MAT B4-250-2101
ST STONE 24 ROOM NUMBER SIGNAGE - REFER TO ACCESSIBILITY REQUIREMENTS AND HADG FOR ADDITIONAL REQUIREMENTS 4 SEALED CONCRETE SHEET NAME:
SF SPECIAL FINISH 25 DECORATIVE SCONCE -MAXIMUM PROJECTION 4" FROM WALL 5 COORDINATE LAUNDRY EQUIPMENT POWER WITH SUPPLIERS SHOP DRAWINGS PRIOR TO ROUGH IN
CONC CONCRETE 26 RECESSED FIRE EXTINGUISHER CABINET -- REFER TO OVERALL FLOOR PLANS FOR LOCATION 12 COORDINATE INSET CARPET WITH OUTLET AND FF&E PLACEMENT

CENTER FIXTURE IN SPACE ALIGN FIXTURES CENTER OVER


CPT
T
CARPET
TILE
27 "SIGHTS & SOUNDS WALL" - REFER TO 7.0 BRAND STYLE GUIDE 19 FLOOR DRAIN WITH TRAP PRIMER IN DISHED RECESS, SLOPE FLOOR TO DRAIN INTERIOR
G GLASS 28 SIGNAGE NOT SHOWN - REFER TO 7.0 BRAND STYLE GUIDE

CENTER THE FIXTURE IN SPACE ALIGN FIXTURES ALONG CENTER THE FIXTURE IN SPACE
QT QUARRY TILE 29 LEVER REQUIRED ON THE SIDE OF TANK OPPOSITE INSIDE CORNER OF WALL. FINISH
B WALL BASE 30 WIRE AND CABLE GROMMETS - REFER TO FFE MANUAL FOR TYPE AND LOCATION
IDENTIFIED BY DIAGONAL LINE CENTERLINE SHOWN IDENTIFIED BY DIAGONAL LINE RF
WC
RESILIENT FLOORING
WALL COVERING
31 DECORATIVE FIXTURE -REFER TO SHEET A4.53 LEGENDS &
32 AVOID BACKSPLASH ON WALL SINK TO ALLOW FOR MIRROR TO BE INSTALLED AT PROPER HEIGHT
33 GRAPHIC APPLIED TO GLAZING - REFER TO 7.0 BRAND STYLE GUIDE NOTES
34 EMPLOYEE WORK SURFACE REFER TO FF&E SPECIFICATION
35 ARTWORK SHEET NUMBER:
36 AVOID BACKSPLASH ON WALL SINK TO ALLOW FOR MIRROR TO BE INSTALLED AT PROPER HEIGHT

A-200
60 AVOID BACKSPLASH ON WALL SINK TO ALLOW FOR MIRROR TO BE INSTALLED AT PROPER HEIGHT

0" 1"
PUBLIC AREA ROOM FINISH SCHEDULE
ROOM WALL CEILING
NUMBER ROOM NAME FLOOR FINISH BASE FINISH ELEV.1 ELEV.2 ELEV.3 ELEV.4 ELEV.5 ELEV.6 ELEV.7 ELEV.8 ELEV.9 ELEV.10 ELEV.11 ELEV.12 ELEV.13 ELEV.14 ELEV.15 ELEV.16 ELEV.17 ELEV.18 ELEV.19 ELEV.20 NOTES
1ST FLOOR
001 VESTIBULE T-01 T-09 PT-07
002 VESTIBULE T-01 B-03 WC-04 on all walls
100 CORRIDOR CPT-02 B-02 WC-10,PL-01, WC-10,PL-0 WC-10,PL-01,
PT-04 1, PT-04 PT-04 2901 Clint Moore Rd, #114
100.1 CORRIDOR T-01 T-09 WC-10 on all walls
Boca Raton, FL 33496
144 STORAGE SEALED CONCRETE PT-03 on all walls
888.901.8008 www.base-4.com
146 ELEV#1
147 ELEV#2 ARCHITECT:
150 SALES OFFICE CPT-03 B-03 PT-03 PT-03, PT-03 PT-03
PT-08 Ricardo J. Muniz-Guillet, AIA
151 STORAGE SEALED CONCRETE PT-03 on all walls 2030 Habersham Trce
152 MENS TOILET T-01 T-09 PT-07 WC-04 WC-04 T-03 WC-04 Cumming, GA 30041
153 WOMENS TOILET T-01 T-09 PT-07 T-03 WC-04 WC-04 WC-04 954.812.6650
154 ICE T-01 B-02 PT-05 on all walls [email protected]
155 PBX SEALED CONCRETE VB-04 PT-05 on all walls
156 MECHANICAL SEALED CONCRETE VB-04 PT-05 on all walls
157 ENGINEERING OFFICE SEALED CONCRETE PT-05 on all walls
158 ELECTRICAL SEALED CONCRETE VB-04 PT-05 on all walls
159 FOOR PREP T-07 QTB-01 PT-05 PT-05,PT-08 PT-05, PT-08 PT-05
160 EMPLOYEE BREAKROOM RF-02 B-04 WC-08 WC-08 WC-08, PT-04 WC-08 PT-05 PT-05 PT-05 PT-05
161 STORAGE SEALED CONCRETE PT-03 PT-03 PT-03 PT-03,PT-
04
162 DRYERS SEALED CONCRETE PT-03 on all walls
163 LAUNDRY SEALED CONCRETE PT-03, PT-04 PT-03, PT-04 PT-03 PT-03 PT-03 PT-03 PT-03, PT-04 PT-03, PT-04
164 LAUNDRY DISCHARGE SEALED CONCRETE B-04 PT-03 on all walls
165 VESTIBULE T-01 WC-04 on all walls
166 POOL DECK AREA SF-01,CO-01r B-06 PT-13 PT-11, PT-04 PT-11 PT-11 PT-11
167 UNISEX T-01 B-05 P-07 WC-04 T-03 WC-04 WC-04, PT-06
168 UNISEX T-01 B-05 PT-07 WC-04 CT-05, T-03 WC-04 WC-04, PT-06
169 POOL EQUIP. SEALED CONCRETE PT-03 on all walls
11/30/2022 8:26:01PM
22/11/30 9:24:23 PM
170 POOL STORAGE SEALED CONCRETE PT-13 PT-03 on all walls
171 PATIO AREA None OWNER:
172 FIRE PUMP SEALED CONCRETE WC-04 on all walls
174 ELEVATOR LOBBY T-01 T-09 PT-07 WC-04, PT-04 WC-04, WC-04, PT-04 WC-04 on all walls
PT-04
175 REGISTRATION T-01 B-03 PT-07
176 MANAGERS OFFICE CPT-03 B-04 PT-03 PT-03,PT-04 PT-03 PT-03
177 WORK STATION T-01 B-04 PT-07 WP-01, WP-01, WC-08, PT-03 PL-01, WC-08,
WC-08 PT-03 PT-04
178 SERVERY T-01 B-04 PT-07 WP-01, WP-01, WC-08, PT-03 PL-01, WC-08, 10655 N.E. 4th Street, Suite 606 |
WC-08 PT-03 PT-04 Bellevue, WA 98004
179 BREAKFAST T-01 B-04 WC-08 WC-08, WC-08,
PL-01,PT-04 PL-01,PT-04
180 HOME2 MARKET T-01 B-03 PT-07 WC-04 [email protected]
181 LOBBY T-01, CPT-03 B-03 PT-07 WC-04 WC-04 WC-03,WC-04 PT-04, PL-01, WC-04, P:(425) 598-8516
WP-01
182 FITNESS ROOM RF-01 B-03 PT-07 WC-07, PT-04 WC-07, WC-07, PT-04 WC-07 PROJECT INFORMATION:
PT-04
184 GUEST LAUNDRY T-01 B-03 PT-07 WC-06 WC-06 WC-06 WC-06,PT-04
185 MECHANICAL SEALED CONCRETE PT-07
186 ENTRY ALCOVE None PT-07
188 OUTDOOR LOUNGE None
195 STAIR#1 None
196 STAIR#2 None
2ND FLOOR
200 CORRIDOR CPT-02 B-02 PT-03, PT-04, WC-10, WC-10,PL-01, R MEDFORD, OR
PL-01 PT-04 PT-04
240 ELEVATOR LOBBY CPT-02 B-02 WC-09 WC-09, WC-09 WC-09, PT-04
PT-04,
PL-01 Prototype Version 3.0
241 HOUSEKEEPING SEALED CONCRETE PT-07 PT-03 on all walls August 2022
242 ELEC/PBX SEALED CONCRETE PT-03 on all walls
ISSUE
243 ICE T-01 B-04 WC-04 on all walls DELTA ISSUE DATE DESCRIPTION
NO.
244 STORAGE SEALED CONCRETE
295 STAIR#1
1 A1 2022.11.30 ISSUED FOR
296 STAIR#2 PERMIT
3RD FLOOR
300 CORRIDOR CPT-02 B-02 WC-10 WC-10, WC-10 PT-04, PL-01
PT-04
340 ELEVATOR LOBBY CPT-02 B-02 WC-09 WC-09, WC-09 WC-09, PT-04
PT-04,
PL-01
341 HOUSEKEEPING SEALED CONCRETE PT-03 on all walls
342 ELEC/PBX SEALED CONCRETE PT-03 on all walls
343 ICE T-01 B-04 WC-04 on all walls
344 STORAGE SEALED CONCRETE
395 STAIR#1 None
396 STAIR#2 None
4TH FLOOR
400 CORRIDOR CPT-02 B-02 WC-10 WC-10, WC-10 PT-04, PL-01
PT-04
440 ELEVATOR LOBBY CPT-02 B-02 WC-09 WC-09, WC-09 WC-09, PT-04
PT-04,
PL-01
441 HOUSEKEEPING SEALED CONCRETE PT-03 on all walls
442 ELEC/PBX SEALED CONCRETE PT-03 on all walls
443 ICE T-01 B-04 WC-04 on all walls
444 STORAGE SEALED CONCRETE
495 STAIR#2
496 STAIR#1

CURRENT ISSUE:

GUESTROOM FINISH SCHEDULE


ROOM NAME FLOOR FINISH WALL BASE CEILING FINISH ELEV.1 ELEV.2 ELEV.3 ELEV.4 ELEV.5 ELEV.6 ELEV.7 ELEV.8 ISSUE FOR PERMIT
KING STUDIO SUITE CPT-01,CPT-07, B-01 PT-07 PT-03, PT-04, PT-03 PT-01 PT-03, PT-02, WC-11
T-01 PL-01
QUEEN QUEEN STUDIO SUITE CPT-01,CPT-07, B-01 PT-07 PT-01 PT-03, PT-02, WC-11 PT-03, PT-04, PL-01 PT-03 CURRENT ISSUE DATE:
T-01
QUEEN QUEEN STUDIO SUITE- ACC. CPT-01,CPT-07, B-01 PT-07 PT-03, PT-04, PT-03, PT-02 PT-01 PT-03, PT-02, WC-11
2022.11.30
CONN.(RIS) T-01 PL-01 DRAWN BY:
KING ONE BEDROOM SUITE CPT-01,CPT-07, B-01 PT-07 PT-03, PT-04, PT-12, WC-11,PT-03 PT-01 PT-03 PT-03, PT-02 WC-11 PT-01 PT-03, PT-02
T-01 PL-01 PJ/RG
KING STUDIO SUITE CONN. CPT-01,CPT-07, B-01 PT-07 PT-01 PT-03, PT-04, PL-01 PT-03, PT-04, PL-01 PT-03, PT-02, WC-11 CHECKED BY:
T-01
KING ONE BEDROOM SUITE ACC(TUB) CPT-01,CPT-07, B-01 PT-07 PT-01 PT-03, PT-02 PT-03, PL-01, PT-04 PT-12, WC-11 PT-01 PT-03, PT-02 PT-03, PT-02 WC-11 LA/RB
T-01 PROJECT #:
QUEEN QUEEN STUDIO SUITE CONN. CPT-01,CPT-07, B-01 PT-07 PT-03, PT-04, PT-03, PT-02, WC-11 PT-01 PT-03, PT-02
T-01 PL-01 B4-250-2101
KING SUITE ACC. CONN.(TUB) CPT-01,CPT-07, B-01 PT-07 PT-03, PT-04, PT-03, PT-02 PT-01 PT-03, PT-02, WC-11 SHEET NAME:
T-01 PL-01

GUESTROOM RESTROOM FINISH SCHEDULE ROOM FINISH


ROOM NAME
RESTROOM- ACC. ONE BEDROOM RIS
FLOOR FINISH
T-01
WALL BASE
B-05
CEILING FINISH
PT-07
ELEV.1 ELEV.2
WC-12, SS-01,PT-04 WC-12, PT-04
ELEV.3 ELEV.4
WC-12, SS-01 WC-12, SS-01
ELEV.5 ELEV.6 ELEV.7 ELEV.8 SCHEDULE
RESTROOM- ACCESSIBLE RIS T-01 B-05 PT-07 WC-12, SS-01 WC-12, PT-04 WC-12, SS-01 WC-12, SS-01
RESTROOM- STANDARD SHOWER T-01 B-05 PT-07 WC-12,SS-01 WC-12, WC-12 WC-12, SS-01
PT-04,SS-01
RESTROOM- ACC. ONE BEDROOM TUB T-01 B-05 PT-07 WC-12, PT-04, SS-01 WC-12, PT-04 WC-12, SS-01 WC-12, SS-01 SHEET NUMBER:
RESTROOM- ACCESSIBLE TUB T-01 B-05 PT-07 WC-12, SS-01 WC-12, PT-04 WC-12, SS-01 WC-12, SS-01

A-201
0" 1"
15 23 25

3' - 3 7/8"
5 1/2" 11' - 10 3/4" 5 1/2" 42' - 3 3/4" 5 1/2" 7' - 2 5/8" 5 1/2" 5 1/2"

5 1/2"
5 1/2"
1 1/4"
2901 Clint Moore Rd, #114

5 1/2"
P Boca Raton, FL 33496
ER-6.1 ER-6.1 888.901.8008 www.base-4.com

2' - 5 1/4"
ER-6.1
ER-6.1 ER-6.1 ER-6.1 170 POOL ARCHITECT:
STORAGE

7' - 2 1/4"
CLEAR
6' - 10 3/8"
169

7' - 0"
POOL EQUIP. 170 Ricardo J. Muniz-Guillet, AIA
GENERAL FLOOR PLAN NOTES

1' - 7 3/4"
5' - 11 1/2"
2030 Habersham Trce

3' - 10 3/8"
169 ER-6.1
5' - 3 3/8" 29' - 0" BASE4 NOTES Cumming, GA 30041
3' - 2 1/8"
954.812.6650

12' - 0 1/8"
IR-6.1
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
3' - 0"
IR-6.1 CLEAR NOTED [email protected]

5 1/2"
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.

5 1/2"
SHOWER
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
ER-6.1 IR-6.1 ER-6.1

5 1/2" 5' - 2"


4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
IR-6.1 AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
IR-6.1 WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
5 1/2"

O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF


GYPSUM WALLBOARD.

- 7 3/4"
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
FR-4.1

3 1/2"
COMMUNICATION ROOM TABLES

15' - 10 5/8"
ER-6.1 IP-4.1 POOL POOL DECK SF-10 8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED

2'

17' - 0"
AREA GUESTROOM INFORMATION.
7' - 6 3/4"

7' - 6 3/8" PATIO AREA


CLEAR
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
7' - 5"

2' - 7 5/8"
IR-6.1 166
171 DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
UNISEX CLEAR ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
168 11/30/2022 8:26:01
8:04:50 PM
SF-9
168
A OWNER:
IP-6.1 A-301D
IP-4.1

2' - 1 1/4"
5 1/2"
1' - 11 7/8"
5 1/2"

ER-6.1 171 GENERAL RCP NOTES

2 5/8"
5 1/2"
165B BASE4 NOTES
167
N 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
7' - 6 1/4"

173
CLEAR

UNISEX ER-6.1
7' - 5"

FR-4.1 LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |

5' - 4 3/8"
167 ER-6.1 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR

4' - 0"
VESTIBULE
LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
Bellevue, WA 98004
SF-8
165 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
7' - 6" IR-6.1 54' - 7 7/8" MATERIALS AND HEIGHTS.
IR-6.1 SH-3.1 PATIO [email protected]
4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
CLEAR CLEAR IR-6.1 RESTROOM DIRECTION OR TO LIMIT AREAS TO 2500 SF P:(425) 598-8516
5 1/2"

173 M 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION.


PROJECT INFORMATION:
6. ALL ACT TILE CENTERED IN ROOM.
SH-3.1
7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
FR-4.1 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
IR-6.1
LAUNDRY OTHERWISE NOTED
SF-7
DISCHARGE SH-3.1
165A
164
IR-6.2 ELEVATOR

P
LOBBY
174 CEILING FINISH LEGEND
1 7/8" MEDFORD, OR
5 1/2" 11 5/8" 3 1/2" 7' - 7 1/4" 5 1/2" 46' - 2 7/8" 5 1/2" 3 1/2" 7' - 7 1/4" 1 1/8" 5 1/2" 8' - 3 1/8" 5 1/2" TYPE
MARK DESCRIPTION
A PRIMED & PAINTED GYPSUM BOARD
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
RESISTANT August 2022
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
A  CONSTRUCTION PLAN  E ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
DELTA ISSUE DATE DESCRIPTION
A-301A A-301D MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE NO.
1/4" = 1'-0"
ONLY-REFER TO SECTIONS
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
GRID SUSPENDED FROM STRUCTURE PERMIT
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
R-1/E PAINTED
R-1/E R-1 R-1/E 4' - 6" TR01 R-1 R-1/E R-1
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
1' - 7" POOL J PRIME AND PAINTED EXTERIOR GYPSUM BOARD
3' - 1 1/2"

STORAGE

3' - 6"
T-3/E 25
4' - 4 1/2" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 6' - 4" 2' - 1" 170 A CEILING FINISH

1' - 1"
1' - 0 1/2" 25 9'-6" CEILING HEIGHT
S-2 S-2 S-2 A S-2 S-2
PT-13 9' - 0"
8' - 3 1/2"

5' - 0" 6' - 8 1/2" T-3/E

3' - 6"
S-2

8' - 3 1/2"
POOL EQUIP. EQ 5' - 2 1/2" EQ 3' - 2" EQ 5' - 2 1/2" 3' - 2" EQ 5' - 2 1/2" EQ B
7' - 6"
169 PT-13
F EQ
CS
11' - 1 5/8" 25
T-3 24
PT-13
POOL DECK
8 AREA
3' - 1 1/2"

166
R-1 R-1 R-1
PT-13
5' - 8 1/2"

5' - 8 1/2"
UNISEX F
11' - 1 5/8"
168 A
R-1/E 9' - 0"
B R-1/E CURRENT ISSUE:
EQ

S20/E
7' - 6"
15cd

PT-07
B R-1/E ISSUE FOR PERMIT
5' - 11 1/2"

S20

10' - 4 1/2"
A-301D
EQ

2' - 7 1/2"
3' - 6 1/2" 1' - 4" 4' - 0 1/2" CURRENT ISSUE DATE:

3' - 11 1/2"
2' - 7 1/2" 5' - 2 1/2" 2' - 7" 3' - 2" 2' - 7 1/2" 5' - 2 1/2" 2' - 7" 3' - 2" 2' - 7 1/2" 5' - 2 1/2" 2' - 7" EQ EQ 2022.11.30
UNISEX DRAWN BY:
167 24 R-1 PJ/RG
EQ

R-1
4' - 5"

S20 B CHECKED BY:


7' - 6" VESTIBULE
S-2 S-2 S-2 S-2 S-2 S-2

3' - 0"
R-1 165 LA/RB
4' - 0 1/2" 4' - 4 1/2" 9' - 0" 9' - 0" 9' - 0" 9' - 0" S20/E
PT-07 PROJECT #:
15cd

S20/E R-1/E
EQ

B4-250-2101
2' - 5"

4' - 6" R-1 R-1/E 2' - 3 1/2" PATIO

2' - 9"
2' - 8"

2' - 0 1/2"
R-1/E R-1 R-1/E TR01 F SHEET NAME:
3' - 6" 1' - 4" RESTROOM

4' - 1"
A-301D
R-1 173
A S20
A 8' - 6"

3' - 2"
8' - 10"

LAUNDRY
PT-07
PT-07
ENLARGED

15cd

V
DISCHARGE
164
4' - 1" 4' - 1"
POOL PLAN
ELEVATOR A
LOBBY 8' - 10"
174
KEY PLAN
SHEET NUMBER:
B  REFLECTED CEILING PLAN 
A-301A 1/4" = 1'-0"

A-301A
0" 1"
6
A-301C

6' - 11" 19' - 7" 18' - 6 1/2" 4' - 10"


2901 Clint Moore Rd, #114
Boca Raton, FL 33496
POOL 888.901.8008 www.base-4.com

3' - 0"
STORAGE
ARCHITECT:

6' - 4 1/2"
11 170
H Ricardo J. Muniz-Guillet, AIA

9 1/2"
H
GENERAL FLOOR PLAN NOTES 2030 Habersham Trce

3' - 0"
B

3' - 6 1/2"
OF-715 OF-715 OF-715 OF-715 OF-715 OF-715
BASE4 NOTES Cumming, GA 30041
OF-711 OF-711 OF-711 OF-711 OF-711 OF-711
POOL EQUIP. 954.812.6650
PFE H 1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
169 DECKS MUST BE INSTALLED W/ RELIEF JOINTS FOR THERMAL [email protected]
NOTED
MOVEMENT & POTENTIAL SETTLING
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHOWER OF-715 SHEATHING, CMU, & CONCRETE.
OF-713 3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
4 M 5 METAL OR WOOD STUDS, CMU, & CONCRETE.
A-301C 4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
2 AS SHOWN ON PLANS.
OF-713 5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
PARTITION WALLS.
20
WALL 6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
3 OF-713 O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
UNISEX 7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
5 H
168 PATIO AREA COMMUNICATION ROOM TABLES
SHOWER
OF-715 171 8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
POOL DECK J GUESTROOM INFORMATION.
7
B AREA 9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
A 166 OF-713 DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
6 A-301D 8 ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
702 11/30/2022 8:26:01
8:04:58 PM
5
7
3' - 6" OWNER:
B
19 22 A
22
13
6
C B A
A 14
A-301D 3' - 6" 3
3 18
4 A-301C 2
EXPANSION JOINT IN COPING
10655 N.E. 4th Street, Suite 606 |
2 A-301D 4 LADDER B
Bellevue, WA 98004

J
10" MAX SEPARATION M 9 1 9
DRINKING FOUNTAIN JOINTS WHERE THE DECK MEET 7"
1 UNISEX PFE 1' - 5 1/2"
THE POOL MUST BE [email protected]
167 12 A-301D 10
WATERTIGHT VESTIBULE
P:(425) 598-8516
165
11 PROJECT INFORMATION:
PATIO
RESTROOM
5' - 5" B
LAUNDRY 173
JOINTS WHERE THE POOL OR
DISCHARGE
WHIRLPOOL COPING MEETS THE DECK
MUST BE PROTECTED FROM THE 164 A

P
RELATIVE PRESSURE OF ADJOINING
DECK MOVEMENT
ELEVATOR
C  FURNITURE AND POWER PLAN  LOBBY
MEDFORD, OR
A-301B 1/4" = 1'-0" 174

Prototype Version 3.0


August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.

1 A1 2022.11.30 ISSUED FOR


PERMIT

PT-03
PT-11

POOL EQUIP. POOL


169 STORAGE

PT-11
170
PT-03

FD

SHOWER
T-04
SEALED
CONCRETE
FD
DRAIN OPENINGS TO BE
PERPENDICULAR TO THE
DIRECTION OF TRAVEL AND
BE LESS THAN 1/2" WIDE.
DRAIN WITH TRAP PRIMER PATIO AREA
FD 171

PT-04
CURRENT ISSUE:
SF-01
FD POOL DECK
T-04 T-04
UNISEX
AREA ISSUE FOR PERMIT
166
168 CO-01
SMOOTH AGGREGATE CURRENT ISSUE DATE:
PORCELAIN DECK. REFER TO
STANDARDS 2022.11.30
PT-11

D DRAWN BY:
A-301D B-06
PJ/RG
CHECKED BY:
PT-04

FD T-04
LA/RB
VESTIBULE PROJECT #:
UNISEX
165
167 B4-250-2101
SHEET NAME:
PT-11 B-06

PATIO
RESTROOM
173
ENLARGED
LAUNDRY
DISCHARGE
POOL PLAN
164
ELEVATOR
P

LOBBY
D 174
 FLOOR FINISH PLAN  SHEET NUMBER:
A-301B 1/4" = 1'-0" KEY PLAN

A-301B
0" 1"
SF-02
SF-02

PT-03
173 2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com

3' - 0"
ARCHITECT:

B-05 B-05 B-05 B-05 Ricardo J. Muniz-Guillet, AIA


GENERAL FLOOR PLAN NOTES 2030 Habersham Trce
Cumming, GA 30041
BASE4 NOTES
12 11 10 9 954.812.6650
 INTERIOR ELEVATION   INTERIOR ELEVATION   INTERIOR ELEVATION   INTERIOR ELEVATION  1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" NOTED [email protected]
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
22 25 SHEATHING, CMU, & CONCRETE.
5 1/2" 8' - 3" 5 1/2" 3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS

5 1/2"

5 1/2"
N AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU

2' - 0 1/2"
WALLS.
SF-02
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX

J
9 ER-6.1 IR-6.1 O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
S20/E 7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
12 A-301D 10 PATIO
PT-03

COMMUNICATION ROOM TABLES

4' - 1"
RESTROOM 8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
SF-02

11 173 GUESTROOM INFORMATION.


CT-01
4' - 1" 4' - 1" 9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION

13' - 11 1/4"

13' - 11 1/4"
IR-6.1

13' - 8 1/4"
PATIO PATIO DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN

CLEAR
RESTROOM RESTROOM ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
S20 11/30/2022 8:26:01
8:05:51 PM

15cd
173

V
173 8' - 1 7/8"

4' - 1"
PATIO
OWNER:
RESTROOM
CT-01
173 CLEAR
HD-01 HD-13
PT-07
HD-06
S20/E GENERAL RCP NOTES

3' - 5"
EL-6.1
HD-06 PA-507 BASE4 NOTES

5 1/2"
SF-02 EL-6.1 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR

5 1/2"
LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
K 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR Bellevue, WA 98004
5 1/2" 8' - 3" 5 1/2" LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
MATERIALS AND HEIGHTS. [email protected]
H  FLOOR FINISH PLAN  G  FURNITURE AND POWER PLAN  F  REFLECTED CEILING PLAN  E  CONSTRUCTION PLAN  4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
P:(425) 598-8516
A-301D A-301D A-301D A-301D DIRECTION OR TO LIMIT AREAS TO 2500 SF
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. PROJECT INFORMATION:
OCCUPANCY
6. ALL ACT TILE CENTERED IN ROOM.
SENSOR WS10
AUDIO/VIDEO 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
FIRE ALARM WC-04 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
T-03 WC-04
WC-04
IR-6.1
PA-507
HD-06

7' - 6"
HD-06
CEILING FINISH LEGEND
7' - 6"

7' - 6"
7' - 0"

7' - 6"

168 MEDFORD, OR
HD-13 TYPE

3' - 6"
MARK DESCRIPTION
HD-01 HD-01
A PRIMED & PAINTED GYPSUM BOARD
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
RESISTANT August 2022
B-05 B-05 B-05 B-05 C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
DELTA ISSUE DATE DESCRIPTION
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE NO.
8  INTERIOR ELEVATION  7  INTERIOR ELEVATION  6  INTERIOR ELEVATION  5  INTERIOR ELEVATION  ONLY-REFER TO SECTIONS
A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
GRID SUSPENDED FROM STRUCTURE PERMIT
AUDIO/VISUAL F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
FIRE ALARM WS10 PAINTED
PT-06 PA-507
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
WC-04 WC-04 T-03 WC-04 J PRIME AND PAINTED EXTERIOR GYPSUM BOARD

HD-06 A CEILING FINISH


PA-507 HD-06
7' - 6"

7' - 6"

7' - 6"
HD-13 9'-6" CEILING HEIGHT

7' - 6"
7' - 0"

167
HD-06 HD-13 HD-06
3' - 6"

HD-06
HD-01 HD-01

B-05 B-05 B-05 B-05

4  INTERIOR ELEVATION  3  INTERIOR ELEVATION  2  INTERIOR ELEVATION  1  INTERIOR ELEVATION 


A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0" A-301D 1/4" = 1'-0"

16
7' - 6" 5 1/2" 3 1/2" 7' - 7" 5 1/2"
HD-01
11 1/2"
CURRENT ISSUE:

5 1/2"

5 1/2"
5' - 7"
UNISEX
WC-04
19
168
UNISEX
168
S20/E
IR-6.1
IR-6.1
ISSUE FOR PERMIT
EQ

M
WC-04

T-01 FLOOR FINISH


HD-06 FD S20 ER-6.1
15cd

7
V

B-05 BASE FINISH

CLEAR
B B

7' - 7"
7' - 5"

7' - 5"
UNISEX CURRENT ISSUE DATE:
A 7' - 6"
T-03

UNISEX FR-4.1
HD-13

2' - 0"
168
6 A-301D 8
PT-07 168 2022.11.30
FD PA-507 DRAWN BY:
EQ

168
8 5
3' - 6" IP-6.1
2' - 7 1/2" 3' - 6 1/2" 1' - 4" PJ/RG
WC-04 HD-12

5 1/2"

5 1/2"
CHECKED BY:
HD-12 UNISEX LA/RB
WC-04
8 B A

2' - 1 1/2"
3' - 6" 167 ER-6.1 PROJECT #:
EQ

PA-507 167
FD 2' - 8" 3' - 6" 1' - 4" FR-4.1 B4-250-2101
FD UNISEX 3

7' - 6 1/2"

CLEAR

CLEAR
M
7' - 5"

7' - 5"

7' - 5"
HD-13 SHEET NAME:
167 UNISEX
2 A-301D 4
T-03

167
WC-04

S20 B

5' - 5"
HD-06
15cd

ENLARGED
V

T-01 FLOOR FINISH 7' - 6"


IR-6.1
EQ

1 7' - 6"
B-05 BASE FINISH 19 UNISEX PT-07 S20/E
WC-04
HD-01
167 IR-6.1 CLEAR POOL
5 1/2"

5 1/2"
M
RESTROOM
7' - 6"
5 1/2" 3 1/2" 7' - 7" 5 1/2"
PLANS
11 1/2" KEY PLAN
SHEET NUMBER:

D
A-301D
 FLOOR FINISH PLAN 
1/4" = 1'-0" A-301D
C  FURNITURE AND POWER PLAN 
1/4" = 1'-0" A-301D
B  REFLECTED CEILING PLAN 
1/4" = 1'-0" A-301D
A  CONSTRUCTION PLAN 
1/4" = 1'-0"
A-301D
0" 1"
PL-01 PT-04

PT-03 WP-01 WP-01 WC-08


PT-03
WC-08 WC-08 2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
8' - 10"

8' - 10"

8' - 10"

8' - 10"
OPEN
BEYOND
ARCHITECT:
163 177 176A
Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
Cumming, GA 30041
954.812.6650
B-04 26 B-04
[email protected]
B-04 B-04 B-04

12  INTERIOR ELEVATION  11  INTERIOR ELEVATION  10  INTERIOR ELEVATION  9  INTERIOR ELEVATION 


A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0"

R-1/E R-1/E
R-1 R-1/E
R-1/E TR01
TR01 TR01 TR01 TR01
PL-01 PT-04 PT-04 PL-01 PL-01 PT-04

WC-08 WC-08

WC-08 WC-08
11/30/2022
2022-11-308:26:01 PM
23:18:05
OPEN
8' - 10"

8' - 10"

8' - 10"

8' - 10"
OPEN OWNER:

8' - 2"

8' - 2"
BEYOND
BEYOND
159A 159B 179B 179A

B-04 B-04 B-04 B-04 10655 N.E. 4th Street, Suite 606 |
Bellevue, WA 98004
8  INTERIOR ELEVATION  7  INTERIOR ELEVATION  6  INTERIOR ELEVATION  5  INTERIOR ELEVATION 
A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0" [email protected]
P:(425) 598-8516
PROJECT INFORMATION:

TR01
FRONT DESK P X-01
PT-04 PL-01 WC-04 PL-01 PT-04 WP-01 WC-04 WP-01 WP-01
MEDFORD, OR

Prototype Version 3.0


August 2022
8' - 10"

OPEN
BEYOND ISSUE
FEC DELTA ISSUE DATE DESCRIPTION
179A 179B 177 NO.

1 A1 2022.11.30 ISSUED FOR


PERMIT

B-03 B-03 B-03 WP-01

4  INTERIOR ELEVATION 
A-303E 1/4" = 1'-0"

403 WC-03 WC-04


8"

PA-200 PA-200 WC-04


WC-04

PA-200
9' - 6"

9' - 6"
8' - 10"

8' - 10"

OPEN TO SF-2
BEYOND

002B
SF-3 181
CURRENT ISSUE:

B-04
PA-104 PA-313 PA-104 820 PA-104 PA-313 PA-104 B-03 PA-202 PA-100 X 14 PA- 104 PA-104 ISSUE FOR PERMIT
3  INTERIOR ELEVATION  2  INTERIOR ELEVATION  CURRENT ISSUE DATE:
A-303E 1/4" = 1'-0" A-303E 1/4" = 1'-0"
2022.11.30
DRAWN BY:
TR01 TR01 TR01 TR01 TR01 TR01 PJ/RG
P
WC-04 WC-04
CHECKED BY:

LA/RB
FIRE ALARM PROJECT #:

OPEN TO B4-250-2101

9' - 6 1/8"
BEYOND
SHEET NAME:
8' - 10"

ENLARGED
LOBBY
ELEVATIONS &
PA- 104 PA-303 PA- 104 PA- 104 PA-303 PA- 104
B-03
PA-100 DETAILS
1 KEY PLAN
 INTERIOR ELEVATION  SHEET NUMBER:
A-303E 1/4" = 1'-0"

A-303E
0" 1"
1' - 3 1/2" 1' - 3 1/2"
5' - 4" 5' - 6" 3' - 1 7/8" 2' - 10" 3' - 7" 3' - 6"
WC-08
2901 Clint Moore Rd, #114
431 PA- 111 X6 404 404 Boca Raton, FL 33496
888.901.8008 www.base-4.com
8' - 0"

ARCHITECT:

3' - 4"
DRYERS 8 17 Ricardo J. Muniz-Guillet, AIA
14
GENERAL FLOOR PLAN NOTES 2030 Habersham Trce

6' - 7 1/2"

6' - 1"
5 PA-309 162
427 404 H 18
LAUNDRY Cumming, GA 30041
304 13 A-304B 15 DISCHARGE BASE4 NOTES
954.812.6650

2' - 11"
STORAGE

P
403 164 1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
[email protected]

4 1/2"
B-04 161 16 402 402 17 A-304B 19 NOTED
6 39 2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
2 A 3' - 8 1/2"

3
SHEATHING, CMU, & CONCRETE.

3
B 20

3
EMPLOYEE 3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
4  INTERIOR ELEVATION  BREAKROOM 1 A-304A 3 A
B
METAL OR WOOD STUDS, CMU, & CONCRETE.

4 1/2"
B LAUNDRY 10 A

1' - 0"
A-304A 1/4" = 1'-0" 4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
160 3' - 9" 163

4 1/2"
AS SHOWN ON PLANS.
4 6 A

6"
9 A-304B 11 5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
13 WALLS.

3
1' - 5" 2' - 8" 1' - 5" 5 A-304B 7 12 6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8
PFE 7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
A B COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
P GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
13' - 5" 5' - 10" 6" 4' - 9" DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
427 ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
11/30/2022 8:26:01
8:07:31 PM
OWNER:
C  FURNITURE AND POWER PLAN 
A-304A 1/4" = 1'-0"
WC-08 PT-04
GENERAL RCP NOTES
304
BASE4 NOTES
1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
8' - 0"

LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |


160 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR Bellevue, WA 98004
LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.

15cd
3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
4' - 0"

3' - 2"

MATERIALS AND HEIGHTS. [email protected]


4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
DIRECTION OR TO LIMIT AREAS TO 2500 SF
P:(425) 598-8516
5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. PROJECT INFORMATION:
B-04 6. ALL ACT TILE CENTERED IN ROOM.
EMPLOYEE STORAGE DRYERS 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
BREAKROOM T1/E
161 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
162
160 OTHERWISE NOTED
3  INTERIOR ELEVATION  T1 D
A-304A 1/4" = 1'-0" T1/E 8' - 0"
T1 T1/E
LAUNDRY
D T1/E T1 T1/E DISCHARGE
D
8' - 0"
SD 8' - 0" SD
164 CEILING FINISH LEGEND
D TYPE MEDFORD, OR
8' - 0" T1/E
SD MARK DESCRIPTION

F
LAUNDRY A PRIMED & PAINTED GYPSUM BOARD
T1/E
CS OS
163
T1 B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
RESISTANT August 2022
T1/E T1 D C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
T1/E 8' - 0" ISSUE
T1 ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED DELTA ISSUE DATE DESCRIPTION
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE NO.
MANAGERS ONLY-REFER TO SECTIONS
T1 T1/E OFFICE D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
F 176 GRID SUSPENDED FROM STRUCTURE PERMIT
D F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &

F
8' - 0" PAINTED
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
3' - 3 1/2" 8' - 0" 10' - 0 1/8" 9' - 11 7/8" 8' - 0" CLG. GRID SUSPENDED FROM STRUCTURE
SD
WC-08 J PRIME AND PAINTED EXTERIOR GYPSUM BOARD

431
B  REFLECTED CEILING PLAN  A CEILING FINISH
A-304A 1/4" = 1'-0" 9'-6" CEILING HEIGHT
8' - 0"

PA- 111

PA-309

14 15
B-04 304
6' - 0 3/4" 3 1/2" 8' - 0 3/8" 3 1/2" 8' - 1 1/4" 3 1/2" 10' - 8 1/2" 3 1/2" 15' - 7 7/8" 5 1/2" 11' - 6 1/2" 5 1/2"

2  INTERIOR ELEVATION 

5 1/2"
A-304A 1/4" = 1'-0" W4
5 1/2"

M
10' - 7 1/4"

3 7/8"
2' - 8 5/8"
ER-6.2 12' - 1 1/4" ER-6.2 7' - 10 1/2"
SH-3.1

5' - 10 5/8"
CLEAR CLEAR
CLEAR
6' - 10 7/8"

5' - 10"

CLEAR CURRENT ISSUE:


6' - 9 5/8"

11' - 3 1/2"
DRYERS IP-4.1 IR-6.2
CLEAR

1 1/2"
STORAGE
6' - 9"

162 CLEAR FR-4.1

10' - 11 3/8"
IR-6.1 IR-4.1 161 IP-4.1 ISSUE FOR PERMIT

CLEAR

5' - 7 1/2"
IP-4.1
IR-6.2

3 1/2"
IP-4.1 IP-4.1 162
13' - 10"

CLEAR

427 431 EMPLOYEE


3 1/2"

3 1/2"

BREAKROOM 161 1' - 9 5/8" LAUNDRY CURRENT ISSUE DATE:


LAUNDRY
160 DISCHARGE
3" 3' - 3" 163 2022.11.30
WC-08 164B 164 164A
4' - 11"

DRAWN BY:

2' - 4 1/4"

3 1/2" 1' - 9 5/8" 2' - 4 1/4"


IR-4.1

5 1/2"
2' 6'
- 0- 0"
1/2" 3 1/2"
IR-6.2 PJ/RG
CHECKED BY:
8' - 0"

160 IP-4.1 IR-6.1 LA/RB


1' - 11"
5' - 0"

PROJECT #:
IR-4.1 IR-4.1
MANAGERS 176B
163 IR-6.4 B4-250-2101
OFFICE IP-4.1
3 1/2"

176 SHEET NAME:


159B
B-04
1' - 10"
5 1/2" 12' - 3" 3 1/2" 41' - 3 3/4" 2' - 0 3/4" 7' - 7 5/8" 3 1/2"
1' - 9 1/2"
ENLARGED
1  INTERIOR ELEVATION  5 1/2" 5 1/2" LAUNDRY
A-304A 1/4" = 1'-0"
PLANS
A  CONSTRUCTION PLAN 
A-304A 1/4" = 1'-0" KEY PLAN
SHEET NUMBER:

A-304A
0" 1"
404 PT-04
PT-04 PT-04

PT-03 PT-03 PT-03


PT-03 PT-03 PT-03

2901 Clint Moore Rd, #114


8' - 0" Boca Raton, FL 33496

8' - 0"

8' - 0"

8' - 0"

8' - 0"
164A 164B 161 888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


GENERAL FLOOR PLAN NOTES 2030 Habersham Trce
Cumming, GA 30041
BASE4 NOTES
B-04 B-04 B-04 B-04 B-04 954.812.6650
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
NOTED [email protected]
20  INTERIOR ELEVATION  19  INTERIOR ELEVATION  18  INTERIOR ELEVATION  17  INTERIOR ELEVATION  16  INTERIOR ELEVATION  2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.
A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0"
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
404 404 O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
PT-03 PT-04 PT-03 PT-03 PT-04 PT-03 7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
PT-03 404 PT-03 COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
17 39
8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
163 164B 11/30/2022 8:26:01
8:08:04 PM
PFE

4' - 0"
OWNER:

B-04 B-04 B-04 B-04 B-04

15  INTERIOR ELEVATION  14  INTERIOR ELEVATION  13  INTERIOR ELEVATION  12  INTERIOR ELEVATION  11  INTERIOR ELEVATION 
A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0"
A-304B
10655 N.E. 4th Street, Suite 606 |
1/4" = 1'-0"
Bellevue, WA 98004

[email protected]
P:(425) 598-8516
PROJECT INFORMATION:

PT-03 PT-03 PT-03

39
8' - 0"

8' - 0"

8' - 0"
OPEN
BEYOND

MEDFORD, OR

1' - 2"
17
Prototype Version 3.0
B-04 B-04 B-04 August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
10 9 8 NO.
 INTERIOR ELEVATION   INTERIOR ELEVATION   INTERIOR ELEVATION 
A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0"
1 A1 2022.11.30 ISSUED FOR
PERMIT

PT-03 PT-03
PT-04
PT-04 PT-03
PT-04
PT-03
8' - 0"

8' - 0"
404 403 162 160
8' - 0"

161
OPEN
403 BEYOND

B-04 SEAL AROUND DRYERS B-04


B-04
6  INTERIOR ELEVATION  5  INTERIOR ELEVATION 
7 A-304B 1/4" = 1'-0" A-304B 1/4" = 1'-0"
 INTERIOR ELEVATION 
A-304B 1/4" = 1'-0"

CURRENT ISSUE:

ISSUE FOR PERMIT


WC-08 PT-03 PT-03 PT-03
CURRENT ISSUE DATE:

4 LAUNDRY 2022.11.30
DRYERS CONCRETE PAD
PT-03

EMPLOYEE
PT-03

DISCHARGE
PT-03

DRAWN BY:
BREAKROOM STORAGE 162
164
PJ/RG

PT-03
161

P
160

PT-03
SEALED CONCRETE SEALED CONCRETE
WC-08

WC-08

SEALED CONCRETE CHECKED BY:


PT-03 LA/RB
PT-03 4
4 PROJECT #:

PT-03
LAUNDRY B4-250-2101
RF-02
163 SHEET NAME:
B-04
SEALED CONCRETE
B-04 PT-03
4
ENLARGED
PT-03

WC-08 PT-03
MANAGERS
OFFICE
LAUNDRY
176 PLANS
KEY PLAN
SHEET NUMBER:
D  FLOOR FINISH PLAN 
A-304B 1/4" = 1'-0"
A-304B
0" 1"
AUDIO/ VISUAL
PFE PT-05 PT-05 FEC PT-08 PT-05 FIRE ALARM PT-05
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
HOUSE
PHONE ARCHITECT:

ELECTRICAL Ricardo J. Muniz-Guillet, AIA

8' - 0"

8' - 0"

8' - 0"
8' - 0"

419
159B
159A CABINET GENERAL FLOOR PLAN NOTES 2030 Habersham Trce
BASE4 NOTES Cumming, GA 30041
PFE

2' - 0"

3' - 8"
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
954.812.6650
NOTED [email protected]
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.
COVE BASE BY HOUSE FIRE COVE BASE BY GENERAL 3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
QTB-01 415 415 QTB-01
GENERAL CONTRACTOR PHONE QTB-01 EXTINGUISHER QTB-01 CONTRACTOR METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
4 3 2 1 AS SHOWN ON PLANS.
 INTERIOR ELEVATION   INTERIOR ELEVATION   INTERIOR ELEVATION   INTERIOR ELEVATION  5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
A-305A 1/4" = 1'-0" A-305A 1/4" = 1'-0" A-305A 1/4" = 1'-0" A-305A 1/4" = 1'-0" WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
ELECTRICAL 11/30/2022 8:26:01
8:08:27 PM
CABINET
OWNER:
10 1/2" 2' - 7" 2' - 4 1/2"

PT-05
415
GENERAL RCP NOTES

4' - 0 1/2"
BASE4 NOTES
HOUSE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR

7"
PHONE LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
PT-05 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
Bellevue, WA 98004
LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.

1' - 9"
FOOR PREP H
3. REFER TO ROOM FINISH SCHEDULES FOR CEILING

J
159 MATERIALS AND HEIGHTS.
FOOR PREP [email protected]
4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER

PT-05
T-07 FLOOR FINISH 159 H P:(425) 598-8516
DIRECTION OR TO LIMIT AREAS TO 2500 SF

2' - 5"

6 1/2"
QTB-01 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION.
BASE FINISH 1 PROJECT INFORMATION:
6. ALL ACT TILE CENTERED IN ROOM.

F
PT-05
7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
FD
4 A-305A 2 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
3
PT-05

6' - 10"
159A CEILING FINISH LEGEND
TYPE MEDFORD, OR
PT-05
MARK DESCRIPTION

2' - 11 1/2" 1' - 9"


A PRIMED & PAINTED GYPSUM BOARD
FLOOR SINK B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
PT-05

PFE
RESISTANT August 2022
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE DELTA ISSUE DATE DESCRIPTION
NO.
PT-05 ONLY-REFER TO SECTIONS
J J
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
GRID SUSPENDED FROM STRUCTURE PERMIT
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
J PRIME AND PAINTED EXTERIOR GYPSUM BOARD
D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN 
A-305A 1/4" = 1'-0" A-305A 1/4" = 1'-0" A CEILING FINISH
9'-6" CEILING HEIGHT

WAITING FOR VENDOR TO CONFIRM BASE


13 15 AND WALL TAG AS ELEVATIONS ARE
26' - 2 3/4" MISSING

5 1/2" 12' - 9 1/4" 5 1/2" 12' - 1" 5 1/2"

3 1/2"

3 1/2"
3' - 4 1/2"

IR-4.1
159B

2' - 0 1/8"
7' - 10 1/2"

DIFFUSER

CURRENT ISSUE:
FOOR PREP IR-6.1
T02 FOOR PREP
159 T02/E
6' - 0"

159
ISSUE FOR PERMIT

11' - 8 1/4"
D
T02/E 8' - 0" T02
3 1/2"
F

IR-4.1
3' - 2 1/2"

4' - 3" 6' - 0" CURRENT ISSUE DATE:


21' - 7 5/8"

25' - 2 1/2"
2022.11.30
7' - 11 1/8"

DRAWN BY:
F

D
6' - 0"

8' - 0"
SD PJ/RG
IP-6.1 CHECKED BY:
4' - 7"

T02 OS T02/E

T02 T02/E LA/RB


CR-4.1 PROJECT #:
3 1/2"

B4-250-2101

7' - 2 1/4"
11' - 11 1/4" SHEET NAME:
5' - 4 1/2"

4' - 6"

SUPPLY IR-6.1
DIFFUSER 2' - 11 1/2" 6' - 0" 2' - 11 1/2" CR-6.1 IP-6.1

ENLARGED
5 1/2"

5 1/2"
F
FOOD PREP
5 1/2" 12' - 9 1/4" 5 1/2" 12' - 1" 5 1/2"
KEY PLAN
SHEET NUMBER:

B
A-305A
 REFLECTED CEILING PLAN 
1/4" = 1'-0"
A
A-305A
 CONSTRUCTION PLAN 
1/4" = 1'-0" A-305A
0" 1"
EQUIPMENT SCHEDULE- BOH LAUNDRY EQUIPMENT SCHEDULE- STORAGE
MARK QTY. DESCRIPTION MANUFACTURER MODEL MARK QTY. DESCRIPTION MANUFACTURER MODEL
2901 Clint Moore Rd, #114
01 1 REFRIGERATION RACK OMNI 01 1 MOBILE REACH-IN FREEZER TRUE T-49F-HC Boca Raton, FL 33496
02 2 WALK-IN COOLER / FREEZER ASSEMBLY AMERICAN PANEL CUSTOM 02 2 REACH-IN REFRIGERATOR TRUE TS-49-HC 888.901.8008 www.base-4.com
03 1 HAND SINK W/ SOAP AND TOWEL DISPENSER ADVANCE TABCO 7-PS-87 03 1 HAND SINK W/ SOAP AND TOWEL DISPENSER ADVANCE TABCO 7-PS-87
04 1 MOBILE WORK TABLE CUSTOM FABRICATED 04 1 MOBILE WORK TABLE ARCHITECT:
CUSTOM FABRICATED
05 1 UNDERCOUNTER DISHMACHINE (HIGH TEMP) CHAMPION UH-100B 05 1 UNDERCOUNTER DISHMACHINE (HIGH TEMP) CHAMPION UH-100B
Ricardo J. Muniz-Guillet, AIA
06 1 DISHTABLE RACK SHELF ADVANCE TABCO DT-6R-11 06 1 DISHTABLE RACK SHELF ADVANCE TABCO DT-6R-11 2030 Habersham Trce
07 3 WALL SHELVING METRO SMARTWALL G3 07 3 WALL SHELVING METRO SMARTWALL G3 Cumming, GA 30041
08 1 DISH / POT WASHING SINKS ADVANCE TABCO 9-23-60-36RL (MODIFIED) 08 1 DISH / POT WASHING SINKS ADVANCE TABCO 9-23-60-36RL (MODIFIED)
954.812.6650
09 1 PRE-RINSE W/FAUCET T&S BRASS B-2278-A12-EI 09 1 PRE-RINSE W/FAUCET T&S BRASS B-2278-A12-EI [email protected]
10 1 SPARE NUMBER 10 1 SPARE NUMBER
11 7 MOBILE COOLER / FREEZER SHELVING METRO METROMAX Q 12 1 UTENSIL RACK W/ SHELF ADVANCE TABCO -
12 1 UTENSIL RACK W/ SHELF ADVANCE TABCO - 13 1 WORKTABLE CUSTOM FABRICATED
13 1 WORKTABLE CUSTOM FABRICATED 14 1 COFFEE MAKER (OPERATOR FURNISHED) FETCO CBS-2152XTS
14 1 COFFEE MAKER (OPERATOR FURNISHED) FETCO CBS-2152XTS 15 1 WALL SHELVING METRO SMARTWALL G3
15 1 WALL SHELVING METRO SMARTWALL G3 16 1 CONVECTION OVEN (VENTLESS) MOFFAT (TURBOFAN) E33D5H2
16 1 CONVECTION OVEN (VENTLESS) MOFFAT (TURBOFAN) E33D5H2 17 2 WALL SHELF CUSTOM FABRICATED
17 2 WALL SHELF CUSTOM FABRICATED 18 1 MOBILE REACH-IN FREEZER TRUE TWT-67~SPEC1
18 1 MOBILE REACH-IN FREEZER TRUE TWT-67~SPEC1 19 4 STORAGE SHELVING METRO METROMAX Q
19 5 STORAGE SHELVING METRO METROMAX Q 20 1 CONVECTION OVEN (VENTLESS) (OPTIONAL) MOFFAT (TURBOFAN) E33D5H2
20 1 CONVECTION OVEN (VENTLESS) (OPTIONAL) MOFFAT (TURBOFAN) E33D5H2 21 1 WORKTABLE CUSTOM FABRICATED
22 1 MICROWAVE OVEN (BELOW) AMANA HDC12A2 22 1 MICROWAVE OVEN (BELOW) AMANA HDC12A2
23 1 BATTER MIX STARTER KIT (OPERATOR FURNISHED) 23 1 BATTER MIX STARTER KIT (OPERATOR FURNISHED)
24 1 WAFFLE MAKER (OPERATOR FURNISHED) WELLS BWB-1SE 24 1 WAFFLE MAKER (OPERATOR FURNISHED) WELLS BWB-1SE
25 1 WAFFLE MAKER (FUTURE) (OPERATOR FURNISHED) WELLS BWB-1SE 25 1 WAFFLE MAKER (FUTURE) (OPERATOR FURNISHED) WELLS BWB-1SE
11/30/2022 8:26:01
8:08:29 PM
26 1 CONVEYOR TOASTER APW WYOTT ECO 4000-350L-HILTON 26 1 CONVEYOR TOASTER APW WYOTT ECO 4000-350L-HILTON
27 1 DISPLAY SHOWCASE EQUIPEX WD780B-2/1 27 1 DISPLAY SHOWCASE EQUIPEX WD780B-2/1 OWNER:
28 1 JUICE DISPENSER (BY VENDOR) BUNN-O-MATIC JDF-4 28 1 JUICE DISPENSER (BY VENDOR) BUNN-O-MATIC JDF-4
29 1 WARMING KETTLE VOLLRATH 72017 29 1 WARMING KETTLE VOLLRATH 72017
30 1 CEREAL DISPENSER SERVER PRODUCTS 88920 30 1 CEREAL DISPENSER SERVER PRODUCTS 88920
31 1 UNDERCOUNTER DISPLAY REFRIGERATOR TRUE TUC-27G-ADA-HC~FGD01 31 1 UNDERCOUNTER DISPLAY REFRIGERATOR TRUE TUC-27G-ADA-HC~FGD01
32 1 UNIT COOLER (COOLER) OMNITEMP 32 1 SPARE NUMBER
33 1 UNIT COOLER (COOLER) OMNI 33 1 SPARE NUMBER
34 1 SPARE NUMBER 34 1 SPARE NUMBER 10655 N.E. 4th Street, Suite 606 |
35 1 REACH-IN DISPLAY FREEZER TRUE TS-23FG-HC~FGD01 35 1 REACH-IN DISPLAY FREEZER TRUE TS-23FG-HC~FGD01 Bellevue, WA 98004
36 1 REACH-IN DISPLAY REFRIGERATOR TRUE TSD-47G-HC-LD 36 1 REACH-IN DISPLAY REFRIGERATOR TRUE TSD-47G-HC-LD
37 1 WATER DISPENSER VIVREAU VI-TAP-1H 37 1 WATER DISPENSER VIVREAU VI-TAP-1H
38 3 COFFEE DISPENSER (OPERATOR FURNISHED FETCO D449 38 3 COFFEE DISPENSER (OPERATOR FURNISHED FETCO D449 [email protected]
P:(425) 598-8516
PROJECT INFORMATION:

MEDFORD, OR

Prototype Version 3.0


August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.

1 A1 2022.11.30 ISSUED FOR


PERMIT

CURRENT ISSUE:

ISSUE FOR PERMIT

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:

PJ/RG
CHECKED BY:

LA/RB
PROJECT #:

B4-250-2101
SHEET NAME:

ENLARGED
FOOD PREP

SHEET NUMBER:

A-305B
0" 1"
RFID

X
3' - 6 1/8"
B

7 1/4" 4 3/4"
1' - 1"

K K
PT-04 PT-05 2901 Clint Moore Rd, #114

3' - 0 1/2"
WC-06 PA-602 4' - 5 1/2"
Boca Raton, FL 33496
PA-602

WC-06
A 888.901.8008 www.base-4.com
PA-601 408
MECHANICAL ARCHITECT:

8' - 11 1/2"
WC-07
7
185 GUEST
GUEST A
LAUNDRY Ricardo J. Muniz-Guillet, AIA

7' - 6"
PT-05
PT-05
LAUNDRY B
SEALED PA-313
184 H 6 A-306B 8 GENERAL FLOOR PLAN NOTES 2030 Habersham Trce

WC-06
184 CONCRETE

7' - 7 1/8"
407 406 BASE4 NOTES Cumming, GA 30041
T-01 5
954.812.6650

K
FD FD 1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
B-03 NOTED [email protected]
PFE
60 MECHANICAL 2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
812 EQ EQ 2' - 4" 1' - 8" 185 SHEATHING, CMU, & CONCRETE.

1' - 8"
WC-06 3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
PT-05

20' - 10 1/2"
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
817 814 AS SHOWN ON PLANS.
WC-07 TV 5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
806 802 WALLS.
7 1/2" 813
805 6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX

TV
1' - 5 1/2" 1' - 0" H O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF

4' - 8 7/8"
807 810 GYPSUM WALLBOARD.
6" 6" 804 7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
WC-07

3 COMMUNICATION ROOM TABLES


FITNESS 8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
ROOM GUESTROOM INFORMATION.
4 A-306B 2 9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
182 DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN

TV

3' - 3 3/4"
RF-01 ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
FITNESS 1 11/30/2022
2022-11-308:26:01 PM
23:19:27
811 811

WC-07
B-03 ROOM
182 OWNER:
REFER TO FITNESS CENTER WEBSITE FOR FLOORING
SPECIFICATION: http://hiltonfitnessguidebook.com/brand/home 803

TV
GENERAL CONTRACTOR TO PROVIDE PLATE MIRROR

3' - 9"
FOR RECEIPT OF DECORATIVE FRAME (REFER TO M 1
HOME 2 FITNESS GUIDE FOR ADDITIONAL INFO.) A-805 GENERAL RCP NOTES
808 BASE4 NOTES
803 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR

TV
RFID
809 LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR

5' - 2 7/8"
H
LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
Bellevue, WA 98004
H
3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
MATERIALS AND HEIGHTS. [email protected]
4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
DIRECTION OR TO LIMIT AREAS TO 2500 SF P:(425) 598-8516
5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION.

2' - 1 3/8"
H PROJECT INFORMATION:

TV
6. ALL ACT TILE CENTERED IN ROOM.
WC-07 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
PA-404 PA-404

D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  3


A-306A 1/4" = 1'-0" A-306A 1/4" = 1'-0"
A-804
CEILING FINISH LEGEND
TYPE MEDFORD, OR
MARK DESCRIPTION
A PRIMED & PAINTED GYPSUM BOARD
21 23 25 26 B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
RESISTANT August 2022
5 1/2" 1 3/4" 11' - 0 3/4" 5 1/2" 5 1/2" 10' - 8 1/4" 5 1/2" 6' - 2 3/8" 5 1/2" C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE DELTA ISSUE DATE DESCRIPTION
5/8" NO.
ONLY-REFER TO SECTIONS
EQ. 6' - 9 7/8" EQ. EQ 7' - 3" EQ D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
GRID SUSPENDED FROM STRUCTURE PERMIT
IR-6.1 SF-5
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED

5 1/2"

5 1/2"
182 H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
SF-4 CLG. GRID SUSPENDED FROM STRUCTURE
6' - 10" 2' - 4" J PRIME AND PAINTED EXTERIOR GYPSUM BOARD

3' - 7"
IR-6.1 FR-6.1 IR-6.1 IR-6.1 ER-6.2
4' - 0"
F

EQ

10' - 7" 6' - 0"


GD-6.1 A CEILING FINISH
F

R-1 R-1/E
R-1 R-1/E 9'-6" CEILING HEIGHT
MECHANICAL
SD

10' - 8 7/8"
10' - 7 1/8"
GUEST 185

3' - 6"
GUEST

10' - 1"
LAUNDRY SD 11' - 5 3/4" 185 MECHANICAL
EQ

LAUNDRY
R-1/E 184 PT-07 184
185 D
EQ

PT-07 R-1

A IR-6.1

4' - 2 1/2"
9' - 3" C
EQ

R-1/E R-1 12' - 2 3/8"

7' - 3" 1' - 8"


ER-6.2

5 1/2"
EQ

8' - 6" 17' - 9 1/2"


R-1/E
R-1/E

5' - 2 1/4"
R-1 IR-6.1 IR-6.1
4' - 11 3/8"

29' - 3 1/4"
31' - 5 5/8"

R-1 A
4' - 11 1/2"

PT-07
9' - 3" CLEAR CURRENT ISSUE:
F

SD

ISSUE FOR PERMIT


R-1 R-1/E FITNESS
ROOM
FITNESS CURRENT ISSUE DATE:
182
6' - 0"

ROOM

21' - 2 1/2"
20' - 11"

CLEAR
2022.11.30
6' - 0"

182

12' - 8"
D GD-6.1 DRAWN BY:
R-1 SF-1
R-1/E 9' - 6"
PJ/RG
CHECKED BY:
R-1/E R-1
LA/RB
4' - 8 5/8"

4' - 8 1/2"

PROJECT #:

B4-250-2101
R-1 R-1/E SHEET NAME:
R-1 R-1/E
2' - 7 1/2"

5 1/2" 3' - 3"


ER-6.2 ER-6.2
6' - 10" 9' - 3 1/2" 8' - 6" 2' - 4"
ENLARGED
5 1/2"

A
FITNESS ROOM
5 1/2" 6' - 3 1/2"
W3
13' - 0 1/4"
W3
10' - 2 1/2" 5 1/2"
PLANS
KEY PLAN
SHEET NUMBER:
B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN 
A-306A 1/4" = 1'-0" A-306A 1/4" = 1'-0"
A-306A
0" 1"
WC-06 PT-04
WC-06

2901 Clint Moore Rd, #114

9' - 3"
Boca Raton, FL 33496
185 888.901.8008 www.base-4.com
ARCHITECT:
406

2' - 6"
408 Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
B-03 B-03 Cumming, GA 30041
2' - 2 1/2" 5' - 6" 2' - 0"
954.812.6650
[email protected]
8  INTERIOR ELEVATION 
A-306B 1/4" = 1'-0"
7  INTERIOR ELEVATION 
A-306B 1/4" = 1'-0"

11/30/2022 8:26:01
8:08:58 PM
WC-06 OWNER:

WC-06 WC-06

OPEN TO
BEYOND
9' - 3"

9' - 3"
406 407 10655 N.E. 4th Street, Suite 606 |
Bellevue, WA 98004

[email protected]
408 P:(425) 598-8516
PROJECT INFORMATION:
407 B-03 B-03 B-03

5  INTERIOR ELEVATION 
A-306B 1/4" = 1'-0"
6  INTERIOR ELEVATION 
A-306B 1/4" = 1'-0"

MEDFORD, OR

Prototype Version 3.0


August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.

FIRE 4 1 A1 2022.11.30 ISSUED FOR


ALARM PT-04 A-504 PT-04
808 1 817 1 813 PERMIT

WC-07 WC-07 WC-07


WC-07

TO OPERABLE COMPONENT
30
17
36 23
9' - 6"

7' - 0"
9' - 3"

9' - 3"
32
32 SF-4
182 814

4' - 0"

MAX
1' - 6" 20' - 0" 806 807 B-03 PA-601
B-03
DRINKING FOUNTAIN
4  INTERIOR ELEVATION  3  INTERIOR ELEVATION 
A-306B 1/4" = 1'-0" A-306B 1/4" = 1'-0"

CURRENT ISSUE:

ISSUE FOR PERMIT


12' - 8"
CURRENT ISSUE DATE:
PA-404 PA-404 PT-04 PA-404 PT-04 PA-404
1 PA-404 1 2022.11.30
PT-04 DRAWN BY:

PJ/RG
6 6
6 6 6 WC-07 CHECKED BY:
WC-07 WC-07
EQ EQ LA/RB
W3 W3 PROJECT #:
9' - 6"

9' - 6"
9' - 3"

9' - 3"

20 SF-1 32 B4-250-2101
OPEN SHEET NAME:
3' - 10"
4' - 0"

808
32
ENLARGED
803 809 B-03 FITNESS ROOM
PFE 812 B-03 PT-04 B-03
ELEVATIONS
2  INTERIOR ELEVATION  1  INTERIOR ELEVATION 
A-306B A-306B KEY PLAN
1/4" = 1'-0" 1/4" = 1'-0"
SHEET NUMBER:

A-306B
0" 1"
CR CR
3 P
PT-05 PT-05
6" 2' - 1 1/2" 5' - 11 1/8"

A
ENGINEERING
ENGINEERING
OFFICE
OFFICE

8' - 9 1/8"
157 2901 Clint Moore Rd, #114
157 Boca Raton, FL 33496
ELECTRICAL 888.901.8008 www.base-4.com

PT-05

PT-05
158 PFE ARCHITECT:
SEALED CONCRETE

3 1/8"
Ricardo J. Muniz-Guillet, AIA

1' - 9 5/8"

9 7/8"
GENERAL FLOOR PLAN NOTES 2030 Habersham Trce
Cumming, GA 30041

33
WALL BASE ELECTRICAL BASE4 NOTES
VB-04 954.812.6650
158 1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
PT-05 WALL PAINT H NOTED [email protected]

4' - 6"
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
PT-05 METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS

2' - 0 1/2"
AS SHOWN ON PLANS.

3 1/2"
MECHANICAL

1' - 4 1/2"
PT-05 5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
7 1/2" 5" 5' - 9 1/2"
156 WALLS.

4' - 1 1/2"

1' - 1"
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
PBX PBX O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
PT-05

PT-05
155 155 OFFICE FURNITURE BY GYPSUM WALLBOARD.
SEALED CONCRETE
OWNER AS REQ'D. 7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
WALL BASE M H COMMUNICATION ROOM TABLES
VB-04

PT-05

PT-05
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
VB-04 WALL BASE MECHANICAL

3' - 7 1/2"
PT-05 WALL PAINT GUESTROOM INFORMATION.
156 9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
PT-05 WALL PAINT SEALED CONCRETE
PT-05 DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
11/30/2022 8:26:01
8:09:10 PM
PT-05 OWNER:

3' - 7 1/2"
FLOOR DRAIN WITH TRAP PRIMER

PT-05

PT-05
IN DISHED RECESS. SEALED CONCRETE GENERAL RCP NOTES

3' - 1 1/2"
SLOPE FLOOR TO DRAIN.
VB-04 WALL BASE BASE4 NOTES
1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
PT-05 WALL PAINT LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR Bellevue, WA 98004
PT-05 LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.

3' - 8 1/2"
3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
B-02 PFE
MATERIALS AND HEIGHTS. [email protected]

10"
4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
ICE ICE MACHINE P:(425) 598-8516
B-02

B-02
DIRECTION OR TO LIMIT AREAS TO 2500 SF
154 ICE
5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. PROJECT INFORMATION:

1' - 10 1/2"
9" 154 6. ALL ACT TILE CENTERED IN ROOM.
PT-05 B-02 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
3 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
CR OTHERWISE NOTED

CEILING FINISH LEGEND


C  FURNITURE AND POWER PLAN  MEDFORD, OR
D  FLOOR FINISH PLAN  A-307 1/4" = 1'-0"
TYPE
A-307 1/4" = 1'-0" MARK DESCRIPTION
A PRIMED & PAINTED GYPSUM BOARD
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
12 13 14 RESISTANT August 2022
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
5 1/2" 5 1/2" ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
FR-4.1 12' - 7 1/2" 2' - 3" 10' - 6 1/4" 5 1/2" DELTA ISSUE DATE DESCRIPTION
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE NO.
ONLY-REFER TO SECTIONS
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR

5 1/2"

5 1/2"
158B M GRID SUSPENDED FROM STRUCTURE PERMIT
F 2' - 11 1/2" F 6' - 8" F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
3' - 11 1/4"
3' - 6"

ER-6.3 ER-6.2 ER-6.2 H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
T-3 T01 T01/E
CLG. GRID SUSPENDED FROM STRUCTURE

7' - 3"
ENGINEERING J PRIME AND PAINTED EXTERIOR GYPSUM BOARD
SD ENGINEERING
OFFICE OFFICE
157 IR-6.1 A CEILING FINISH
3' - 6"

157
ELECTRICAL 9'-6" CEILING HEIGHT

3 1/2"
3' - 1" 6' - 3" 3' - 1"

14' - 0 1/2"
158

13' - 10"

CLEAR
6' - 0"

SD ELECTRICAL
T01/E A T01 158
8' - 0"
6' - 2 1/2" IR-4.2 IP-6.1
3' - 3"

4' - 1 5/8"
5' - 0"

T-3/E
5 1/2"

158A

1' - 10"
GD-6.1 IR-4.1

3 1/2"
5' - 9 7/8"

6' - 4 1/8"

6' - 7"
CS
EQ

T-3 PBX
CLEAR
35' - 0"

35' - 0"

7' - 10 1/2"
MECHANICAL

CLEAR
155 IR-6.1 CURRENT ISSUE:

7' - 9"
156
T-3/E PBX
MECHANICAL ISSUE FOR PERMIT
EQ

155 155 IR-4.1


5' - 9 7/8"

1' - 7"
SD
156

3 1/2"
23' - 11 1/2"

CURRENT ISSUE DATE:


T-3/E 12' - 7 1/2"
2022.11.30
3' - 2 1/2"

C
T02/E DRAWN BY:
F

12' - 2 3/8"

PJ/RG
7' - 9 3/8"

T02

7' - 11"
CHECKED BY:
5' - 9 7/8"

SD
4' - 7"

LA/RB

CLEAR
12' - 7"
PROJECT #:
T-3 4' - 3" 6' - 0" CR-4.1 IR-6.1 B4-250-2101

3 1/2"
SHEET NAME:

R-1 R-1/E
5' - 0"

ICE

4' - 6"
ICE
154

3' - 6" 6' - 0" D


GD-6.1 CR-6.1 CR-6.1 154
ENLARGED BOH
8' - 0"
PLANS
5 1/2"

6"
156

KEY PLAN
5 1/2" 10' - 5 1/2" 2' - 2" 4' - 1 1/2" 7' - 10 1/4" 10 3/8" 3 1/2"
SHEET NUMBER:

B
A-307
 REFLECTED CEILING PLAN 
1/4" = 1'-0"
A
A-307
 CONSTRUCTION PLAN 
1/4" = 1'-0"
5 1/2"

A-307
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


GENERAL FLOOR PLAN NOTES 2030 Habersham Trce
BASE4 NOTES Cumming, GA 30041
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
954.812.6650
NOTED [email protected]
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
PT-04 ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
11/30/2022 8:26:01
8:09:27 PM
PT-03 PT-04 PT-03
PT-03 PT-03 PT-03 PT-03
OWNER:
8' - 0"

8' - 0"

8' - 0"
GENERAL RCP NOTES
7' - 0"

7' - 0"
176B 176A
BASE4 NOTES
1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
Bellevue, WA 98004
B-04 B-04 B-04 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
B-04
MATERIALS AND HEIGHTS. [email protected]
ALL OFFICE FURNITURE BY OWNER AS REQUIRED ALL OFFICE FURNITURE BY OWNER AS REQUIRED 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
ALL OFFICE FURNITURE BY OWNER AS REQUIRED ALL OFFICE FURNITURE BY OWNER AS REQUIRED
DIRECTION OR TO LIMIT AREAS TO 2500 SF P:(425) 598-8516
5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION.
PROJECT INFORMATION:
4  INTERIOR ELEVATION  3  INTERIOR ELEVATION  2  INTERIOR ELEVATION  1  INTERIOR ELEVATION  6. ALL ACT TILE CENTERED IN ROOM.
A-308A A-308A A-308A A-308A 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
A-304B 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED

5 1/2" 7' - 7 5/8" 3 1/2"


1' - 9 1/2"
1' - 10" 5 1/2" OFFICE FURNITURE
CEILING FINISH LEGEND
5 1/2"

BY OWNER AS REQ'D. TYPE MEDFORD, OR


MARK DESCRIPTION
5 1/2"

3 1/2" 1' - 9 5/8"

A PRIMED & PAINTED GYPSUM BOARD


PT-03 B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
IR-6.2 IP-4.1 RESISTANT August 2022
176B

PT-03
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
6' - 6 1/2"

ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE


IP-4.1 T1/E DELTA ISSUE DATE DESCRIPTION
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
F

NO.
T1 3 ONLY-REFER TO SECTIONS
MANAGERS MANAGERS MANAGERS MANAGERS
OFFICE OFFICE D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.

PT-03
OFFICE OFFICE 1 A1 2022.11.30 ISSUED FOR
7' - 11 1/8"
TWC

SD
GRID SUSPENDED FROM STRUCTURE PERMIT
176 176 176 2 A-308A 4 176
IR-6.1 F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
D H PAINTED
176A CPT-03 FLOOR FINISH
8' - 0" 1 H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
3' - 5 3/4"

A B-04 WALL BASE CLG. GRID SUSPENDED FROM STRUCTURE


OFFICE J PRIME AND PAINTED EXTERIOR GYPSUM BOARD
IR-6.4 FURNITURE BY
IR-6.1 OWNER AS REQ'D. PT-03
5 1/2"

A CEILING FINISH
9'-6" CEILING HEIGHT
5 1/2"

5 1/2" 11' - 6 5/8" 5 1/2"

A CONSTRUCTION PLAN B REFLECTED CEILING PLAN C FURNITURE AND POWER PLAN D FLOOR FINISH PLAN
A-308A 1/4" = 1'-0" A-308A 1/4" = 1'-0" A-308A 1/4" = 1'-0" A-308A 1/4" = 1'-0"

CURRENT ISSUE:

STRIP FLUORESCENT
COVE ISSUE FOR PERMIT
FIXTURES

CURRENT ISSUE DATE:

2022.11.30
SUSPENDED GYP.
BD. DRAWN BY:
CEILING
PJ/RG
CHECKED BY:
REFER TO
LA/RB
CLG. PLAN
PROJECT #:

SUSPENDED B4-250-2101
FINISH TO MATCH CEILING ACT SYSTEM SUSPENDED
SHEET NAME:
WIRE
REFER TO

SERVERY
CEILING PLAN
LAUNDRY
ENLARGED
ADMINISTRATION
AREAS
9 KEY PLAN
 WORKSTATION CEILING DETAILS 
SHEET NUMBER:
A-308A 1/4" = 1'-0"

A-308A
0" 1"
PT-03 2901 Clint Moore Rd, #114
Boca Raton, FL 33496
PT-08
PT-03 888.901.8008 www.base-4.com
PT-03
ARCHITECT:
PT-03
Ricardo J. Muniz-Guillet, AIA
GENERAL FLOOR PLAN NOTES

8' - 0"

8' - 0"
2030 Habersham Trce

6' - 11"
6' - 8"
8' - 0"

151
BASE4 NOTES Cumming, GA 30041
AHU UNIT
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
954.812.6650
AHU UNIT NOTED [email protected]
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
B-03 B-03 B-03 METAL OR WOOD STUDS, CMU, & CONCRETE.
B-03 4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
7  INTERIOR ELEVATION  6  INTERIOR ELEVATION  5  INTERIOR ELEVATION  WALLS.
8 A-308B 1/4" = 1'-0" A-308B 1/4" = 1'-0" A-308B 1/4" = 1'-0" 6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
 INTERIOR ELEVATION  O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
A-308B 1/4" = 1'-0" GYPSUM WALLBOARD.
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
11/30/2022 8:26:01
8:09:52 PM
OWNER:

GENERAL RCP NOTES


BASE4 NOTES
1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
Bellevue, WA 98004
3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
MATERIALS AND HEIGHTS. [email protected]
4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
DIRECTION OR TO LIMIT AREAS TO 2500 SF P:(425) 598-8516
PT-08 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION.
PROJECT INFORMATION:
6. ALL ACT TILE CENTERED IN ROOM.
7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
PT-03 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
PT-03 PT-03 OTHERWISE NOTED
W3
PT-03
9' - 3"

9' - 3"

9' - 3"

9' - 3"
ELECTRICAL
7' - 0"

7' - 0"
150 PANEL
CEILING FINISH LEGEND
TYPE MEDFORD, OR
MARK DESCRIPTION
A PRIMED & PAINTED GYPSUM BOARD
B-03 B-03 B-03 B-03 B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
ALL OFFICE FURNITURE BY OWNER AS REQUIRED
RESISTANT August 2022
ALL OFFICE FURNITURE BY OWNER AS REQUIRED ALL OFFICE FURNITURE BY OWNER AS REQUIRED ALL OFFICE FURNITURE BY OWNER AS REQUIRED C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE DELTA ISSUE DATE DESCRIPTION
NO.
4  INTERIOR ELEVATION  3  INTERIOR ELEVATION  2  INTERIOR ELEVATION  1  INTERIOR ELEVATION  ONLY-REFER TO SECTIONS
A-308B 1/4" = 1'-0" A-308B 1/4" = 1'-0" A-308B 1/4" = 1'-0" A-308B 1/4" = 1'-0" D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
GRID SUSPENDED FROM STRUCTURE PERMIT
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
J PRIME AND PAINTED EXTERIOR GYPSUM BOARD

A CEILING FINISH
9'-6" CEILING HEIGHT

14 16

5 1/2" 1' - 11" 2' - 10 1/4" 7' - 6 7/8" 5 1/2"

3 1/2"

15cd IR-4.1

3 1/2"
V

PT-03 1' - 10" 3' - 8"


J

STORAGE FD STORAGE
6
PT-03

151 CR-4.1
151 STORAGE
SD
S20

6' - 11 3/8"
PT-03

SEALED FLOOR 5 A-308B 7 151


CONCRETE FINISH STORAGE CURRENT ISSUE:
8 S20/E A 151
GD-6.1

3' - 5"
AHU UNIT 8' - 0" 151

PT-03
ISSUE FOR PERMIT

2' - 0 5/8"
3 1/2"

3 1/2"
150
PT-03
IR-4.1 CURRENT ISSUE DATE:

4' - 1" 1' - 9" 2022.11.30


T1/E T1 DRAWN BY:
SALES OFFICE 2SALES OFFICE
150 PJ/RG

9' - 8 1/8"

9' - 8 1/8"
150
1 A-308B 3 SALES OFFICE CHECKED BY:
F

SD IF-6.1
3 1/2" 6"

CPT-03 FLOOR FINISH GD-6.1


PT-03

PT-03

150 LA/RB
4 SALES OFFICE
B-03 BASE FINISH 150 PROJECT #:
H D ER-6.2 B4-250-2101
3' - 1"

9' - 3"
PT-03 SHEET NAME:
ER-6.1

5 1/2"

5 1/2"
B

5 1/2" 6' - 5 5/8"


W3
6' - 1 7/8" 5 1/2"
ENLARGED
ADMINISTRATION
AREAS
D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN 
A-308B A-308B A-308B A-308B KEY PLAN
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
SHEET NUMBER:

A-308B
0" 1"
2901 Clint Moore Rd, #114
WC-04 Boca Raton, FL 33496
888.901.8008 www.base-4.com
OCCUPANCY
SENSOR ARCHITECT:
OCCUPANCY
SENSOR WC-04 WC-04 FIRE ALARM
AUDIO/VISUAL
FIRE ALARM
Ricardo J. Muniz-Guillet, AIA
PA-204
PA-204 GENERAL FLOOR PLAN NOTES 2030 Habersham Trce
PA-507 HD-06 Cumming, GA 30041

8' - 6"

8' - 6"
PA-507 HD-06 HD-06 BASE4 NOTES
HD-13
954.812.6650
153

8' - 6"
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
NOTED [email protected]
HD-06 HD-06
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
SHEATHING, CMU, & CONCRETE.
HD-01 HD-01 3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS
PT-04 T-09 HD-13 T-09 T-09 AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
8  INTERIOR ELEVATION  7  INTERIOR ELEVATION  6  INTERIOR ELEVATION  O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
A-309A A-309A A-309A GYPSUM WALLBOARD.
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS
11/30/2022
2022-11-308:26:01 PM
23:21:31
OWNER:

GENERAL RCP NOTES


BASE4 NOTES
1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
LOCATIONS OF RELATED ITEMS. 10655 N.E. 4th Street, Suite 606 |
AUDIO VISUAL 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR Bellevue, WA 98004
FIRE ALARM LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
WC-04 OCCUPANCY
SENSOR 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING
PA-204
MATERIALS AND HEIGHTS. [email protected]
OCCUPANCY 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER
T-03 FIRE ALARM SENSOR T-03 WC-04 WC-04
DIRECTION OR TO LIMIT AREAS TO 2500 SF
P:(425) 598-8516
5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. PROJECT INFORMATION:
PA-204 6. ALL ACT TILE CENTERED IN ROOM.
PA-507 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
PA-507
8' - 6"

8' - 0"

8' - 0"

8' - 0"

8' - 0"
HD-06 HD-06 8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
152 HD-13 OTHERWISE NOTED
HD-06 HD-06

HD-01 HD-01

CEILING FINISH LEGEND


T-09 T-09 HD-13 T-09 T-09 T-09 TYPE MEDFORD, OR
MARK DESCRIPTION
A PRIMED & PAINTED GYPSUM BOARD
5  INTERIOR ELEVATION  4  INTERIOR ELEVATION  3  INTERIOR ELEVATION  2  INTERIOR ELEVATION  1  INTERIOR ELEVATION  B PRIMED & PAINTED GYPSUM BOARD-MOISTURE Prototype Version 3.0
A-309A 1/4" = 1'-0" A-309A 1/4" = 1'-0" A-309A 1/4" = 1'-0" A-309A 1/4" = 1'-0" A-309A 1/4" = 1'-0" RESISTANT August 2022
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED ISSUE
DELTA ISSUE DATE DESCRIPTION
MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE NO.
ONLY-REFER TO SECTIONS
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG. 1 A1 2022.11.30 ISSUED FOR
GRID SUSPENDED FROM STRUCTURE PERMIT
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
J PRIME AND PAINTED EXTERIOR GYPSUM BOARD

A CEILING FINISH
9'-6" CEILING HEIGHT

16

3 1/2" 7' - 6 7/8" 5 1/2"

HD-13 19 PA-204

3 1/2"

3 1/2"
PA-507 HD-06
T-03
8 FR-4.1
3' - 5"

FLOOR DRAIN
WC-04

5' - 0 1/4"
CR-4.1
WC-04

7 HD-01 2' - 0 1/2" 3' - 6 1/2" 1' - 9"

6' - 11 1/4"
T-01 WOMENS H
T-09 TOILET HD-06 WOMENS
8 A-309A 6 S20 TOILET GD-6.1
WOMENS 153 I PT-07 CURRENT ISSUE:
TOILET WOMENS 153
5 S20/E TOILET 153

1' - 11"
153

3 1/2"

3 1/2"
M
A
WC-04 HD-12
2' - 11" 153
15cd

8' - 6"
FR-4.1 ISSUE FOR PERMIT
V
D
PA-507 19 PA-204

7"
3 1/2"
7"
10 1/2"

HD-06

3 1/2"
T-03 MENS TOILET CURRENT ISSUE DATE:
CR-4.1 FR-4.1
3' - 5 1/8"

FLOOR DRAIN
WC-04

8 152 2022.11.30

5' - 0 3/4"
3 HD-06
MENS TOILET HD-13 S20/E PT-07

6' - 11 3/4"
DRAWN BY:
WC-04

H HD-01 MENS TOILET


152 S20 GD-6.1
4 A-309A 2 A 152 PJ/RG
T-01 I 8' - 0" CHECKED BY:
3' - 5"

T-09 MENS TOILET M 1 152

1' - 11"
152
2' - 0 1/2" 3' - 6 1/2" 1' - 9" LA/RB
2' - 11" 15cd IR-4.1
WC-04 PROJECT #:

3 1/2"

3 1/2"
V

B4-250-2101
3 1/2" 7' - 6 7/8" 5 1/2" SHEET NAME:
HD-12
ENLARGE
PUBLIC
D
A-309A
 FINISH FLOOR PLAN  C
A-309A
 FURNITURE AND POWER PLAN 
A-309A
B  REFLECTED CEILING PLAN  A
A-309A
 CONSTRUCTION PLAN  RESTROOM
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
PLANS &
KEY PLAN
ELEVATIONS
SHEET NUMBER:

A-309
0" 1"
AUDIO/VISUAL ELEVATOR AND SURROUND --FINISH
OA-502 TO BE BRUSHED STAINLESS STEEL
FIRE ALARM
WC-04 PT-04

WC-04 PT-04 WC-04 WC-04 WC-04


2901 Clint Moore Rd, #114
OA-502 Boca Raton, FL 33496

3' - 0"
888.901.8008 www.base-4.com
8' - 10"

8' - 10"
8' - 10"
ARCHITECT:
164A PA-504
SF-7 165A SF-6
Ricardo J. Muniz-Guillet, AIA

4' - 0"
2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]
T-09 T-09 FEC
T-09
7
A-504
6
1  INTERIOR ELEVATION  2 3  INTERIOR ELEVATION  A-504
 INTERIOR ELEVATION 
A-310A 1/4" = 1'-0" A-310A A-310A 1/4" = 1'-0" 23 25 26
1/4" = 1'-0"

3 1/2" 7' - 8 3/8" 5 1/2" 6' - 2 1/2" 2' - 0 3/4" 5 1/2" 6' - 9 1/2" 2' - 4 1/8" 5 1/2"

1' - 4 1/2" 4' - 4 1/2" 4' - 7"


2' - 3 1/2" 8 1/2"

5 1/2"
P
173 172 N
F

1' - 0" 2' - 5"


PFE ER-6.1 11/30/2022 8:26:01
8:10:33 PM

J
7' - 6 5/8" ER-6.1 OWNER:
LINEN CHUTE
PATIO
A

5 1/2"
RESTROOM

1 1/2"
PATIO IR-6.1
VESTIBULE 173 RESTROOM T-3/E M
165 5 173
IR-6.1

2' - 8 5/8"
2 3/8"
FIRE PUMP FR-4.1

13' - 11 1/4"
6' - 10"
FIRE PUMP

1 1/2"
8 A-310B 6 A 172 SH-3.1
B

15cd
8' - 6"

V
172
FIRE PUMP C 10655 N.E. 4th Street, Suite 606 |
8 1/2"

7 172 S20/E 12' - 2 3/8" 165A Bellevue, WA 98004


P

EQ EQ

2' - 8"
LAUNDRY 12 SF-7
FR-4.1
DISCHARGE LAUNDRY

2' - 5" 1' - 0"

5' - 7 1/2"
2' - 0 5/8"
[email protected]
CR

164 11 A-310B 9 DISCHARGE


3

4' - 1" T-3 ER-6.1 P:(425) 598-8516


164 IR-6.2 FR-4.1 IR-6.1
4' - 6" 10
R-1
A PROJECT INFORMATION:

4' - 0"
WS10

10' - 7 3/8"
164A

5 1/2"
J J K
9"

2' - 10"

T1/E

5' - 4 3/4"

4' - 7 1/2"
R-1/E EL-6.1 ST-6.1
2' - 8" 1' - 4"
IR-6.2
ELEVATOR
LOBBY 1' - 1" 5' - 9 3/8" 1' - 1" IP-4.1
ELEV#2

3 1/2"
174 ELEV#2 176B MEDFORD, OR
147 MANAGERS R-2
OFFICE

3' - 0"
OA-502 ELEV#2

2' - 11 7/8" 2' - 11 7/8"


176 SD
Prototype Version 3.0
TWC

R-1
R-2/E

7' - 11 1/8"
MANAGERS
STAIR#1 1' - 8 7/8" August 2022
OFFICE

2' - 11 5/8"

18' - 3 7/8"
H 195 T1 ELEVATOR EL-6.1 ISSUE
176 O01 CS H MANAGERS
ELEVATOR LOBBY EL-6.1 DELTA ISSUE DATE DESCRIPTION
OFFICE NO.
A

F
LOBBY 174
D 8' - 10" 176
8' - 0" 174 1 A1 2022.11.30 ISSUED FOR
IR-6.1 PERMIT

3' - 0"
5 1/2"
ELEV#1
R-2 R-1/E

5' - 1 3/8"
ELEV#1
146
ELEV#1
2
3' - 1 1/2"

PA-504
R-1/E R-1
1 A-310A 3
9"

5 1/2"

5 1/2"
FEC H
3' - 10" IR-6.1 ST-6.1
EL-6.1

5 1/2" 8' - 4 1/4" 5 1/2" 9' - 0 1/2" 5 1/2"


2' - 2 1/2" 1' - 10" G
2' - 6 1/2" 2' - 3 1/2"

X-01

R-1/E
F
SF-6

CURRENT ISSUE:
RFID

ISSUE FOR PERMIT


C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN 
CURRENT ISSUE DATE:
A-310A 1/4" = 1'-0" A-310A 1/4" = 1'-0" A-310A 1/4" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE
ENLARGE 1ST
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
FLOOR
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
ELEVATOR
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD LOBBY
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-310A
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

T-3 T-3/E

T-3/E T-3/E T-3


T-3
WC-04 WC-04
WC-04 WC-04 WC-04
WC-04
FIRE ALARM
PT-04
11/30/2022 8:26:01
8:10:53 PM
12' - 2 3/8"

12' - 2 3/8"

12' - 2 3/8"
PATIO
RESTROOM OWNER:
173

172 FIRE PUMP

WC-04

WC-04
PFE 4
172

3' - 6"
FLOOR
DRAIN B-03

WC-04

WC-04
1' - 6"

WC-04 T-01
10655 N.E. 4th Street, Suite 606 |
T-09 Bellevue, WA 98004
4
B-03 PFE B-03 B-03 B-03 FLOOR
DRAIN
T-03 [email protected]
P:(425) 598-8516
WC-04
12  INTERIOR ELEVATION  11  INTERIOR ELEVATION  10  INTERIOR ELEVATION  9  INTERIOR ELEVATION  PROJECT INFORMATION:
A-310B 1/4" = 1'-0" A-310B 1/4" = 1'-0" A-310B 1/4" = 1'-0" A-310B 1/4" = 1'-0"

ELEVATOR
LOBBY
174
ELEV#2
T-01 147
MEDFORD, OR
B-03

Prototype Version 3.0

WC-04
August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.
WC-04
1 A1 2022.11.30 ISSUED FOR
OCCUPANCY OCCUPANCY
WC-04 FIRE ALARM WC-04 FIRE ALARM PERMIT
SENSOR SENSOR
WC-04 ELEV#1

WC-04
146

13

1' - 6"
B-03 B-03 B-03 B-03

8  INTERIOR ELEVATION  7  INTERIOR ELEVATION  6  INTERIOR ELEVATION  5  INTERIOR ELEVATION 


A-310B 1/4" = 1'-0" A-310B 1/4" = 1'-0" A-310B 1/4" = 1'-0" A-310B 1/4" = 1'-0"

CURRENT ISSUE:

D  FLOOR FINISH PLAN 


ISSUE FOR PERMIT
A-310B 1/4" = 1'-0"

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE
ENLARGE 1ST
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
FLOOR
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
ELEVATOR
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD LOBBY
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-310B
0" 1"
AUDIO/VISUAL
FIRE ALARM
WC-09 PT-04 WC-09 PL-04 PT-04

WC-09 WC-09 WC-09 WC-09 WC-09 WC-09

OA-503
2901 Clint Moore Rd, #114
OA-503

7' - 6"

7' - 6"

7' - 6"
Boca Raton, FL 33496
240 241
888.901.8008 www.base-4.com
ARCHITECT:
PA-808 PA-808
Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
B-02 B-02 B-02 B-02 B-02 B-02 Cumming, GA 30041
954.812.6650
[email protected]
4  INTERIOR ELEVATION  3  INTERIOR ELEVATION  2  INTERIOR ELEVATION  1  INTERIOR ELEVATION 
A-311A 1/4" = 1'-0" A-311A 1/4" = 1'-0" A-311A 1/4" = 1'-0" A-311A 1/4" = 1'-0"

21 22 23 25 26
2 3/8"
5 1/2" 1 1/2" 10' - 10 1/8" 5 1/2" 8' - 3 5/8" 5 1/2" 9' - 1 5/8" 5 1/2"

5 1/2"
N
11/30/2022 8:26:01
8:11:10 PM
2' - 8" EQ EQ ER-6.1 ER-6.1 OWNER:

EQ
T-3/E

5 1/2"

1 1/2"
EQ

2 1/2"
ER-6.1

8' - 5 7/8"
1' - 5"
4' - 1" 4' - 1" HOUSEKEEPING M
T-3 ELEC/PBX 241
ER-6.2

2' - 8 5/8"
HOUSEKEEPING IR-6.1 ER-6.1

6' - 11 1/2"
242 ELEC/PBX

1 1/2"
6' - 10"
HOUSEKEEPING 241 SH-3.1
ELEC/PBX OS
SD C 242 10655 N.E. 4th Street, Suite 606 |
241 C 9' - 1 3/8" Bellevue, WA 98004
242

EQ
SD 9' - 1 3/8" FR-4.1

3 1/2"
10 5' - 4"

F
10' - 0"
[email protected]
9 1/2"

PT-07 FR-4.1
6 1/2"

9 A-311B 11 P:(425) 598-8516

5' - 1 7/8"
OS
FR-4.1
PROJECT INFORMATION:
12
T-3/E T-3 T-3/E

EQ
EQ
SH-3.1 242

7' - 11 3/4"

1' - 9"
A

EQ
EL-6.1 ST-6.1
SH-3.1

5 1/2"
3' - 3" 3" SH-3.1 K
ST-6.2
241

3 1/2"
FR-4.1 IP-4.1

2' - 6"
MEDFORD, OR

4' - 2"
6' - 4" ELEV#2 ELEV#2

5' - 2"
147 147
R-4 ELEV#2
Prototype Version 3.0

3' - 4"
6 1/2"
147
August 2022
GD-6.1
R-1

2' - 0"
ISSUE
DELTA ISSUE DATE DESCRIPTION

4' - 8 1/2"

18' - 3 7/8"
2' - 7 1/2"
NO.

16' - 2 1/8"
OA-503 O01 R-2

2' - 0"
EL-6.1 EL-6.1 1 A1 2022.11.30 ISSUED FOR
R-1/E PERMIT
PA-808 ELEVATOR
LOBBY

9 1/2"
10 1/2"

SD

3' - 4"
520

FR-4.1
SD

240
ELEVATOR R-4
P

P
ELEV#1
F

LOBBY

3' - 11"
146 10 1/2"
ELEV#1
240
4' - 2" 6
7' - 5"

146 ELEV#1
2 A-807.A

4' - 3"
146

3 1/2"
1 A-311A 3 R-1
ELEVATOR
FR-4.1 FR-4.1

4' - 8 1/2"
LOBBY

5 1/2"
4 240 H

3' - 6 3/4"
ICE A ICE
F FR-4.1 FR-4.1 EL-6.1
7' - 6" ST-6.1
243 5 9' - 1 3/8" 243

6' - 10 1/4"
R-1/E R-1/E
8 A-311B 6 ICE
243

3 1/2"
3' - 3 1/2"

5 1/2" 3' - 5 1/4"


7 3' - 0" FR-4.1
3' - 8 1/2" IR-6.1 CR-6.2
FR-4.1
2' - 1"

432 FR-4.1
CR-6.1 CR-6.1

5 1/2"
240 X F

5 1/2" 2' - 5 3/8" 3' - 6 1/8" 5' - 0 1/4" 5 1/2" 6' - 2 1/4" 2' - 1 1/4" 5 1/2" 9' - 0 1/2" 5 1/2" CURRENT ISSUE:

3 1/2"
ISSUE FOR PERMIT
C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN 
A-311A 1/4" = 1'-0" A-311A 1/4" = 1'-0" A-311A 1/4" = 1'-0"
CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE
ENLARGE
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
TYPICAL
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
ELEVATOR
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD LOBBY
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-311A
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce
Cumming, GA 30041
954.812.6650
[email protected]

PT-03
PT-03

PL-01 PT-04 PL-01 PT-04

PT-03
ELEC/PBX
242
PT-03 PT-03 PT-03 PT-03 PT-03 PT-03
SEALED CONCRETE

PT-03
PT-03
PT-03

PT-03
PT-03
4
241 242 HOUSEKEEPING
PT-03 241
RF-03 4 11/30/2022 8:26:01
8:11:29 PM

PT-03
SEALED CONCRETE OWNER:
B-03 B-03 B-03 B-03 B-03
PT-03
7
A-807.A PT-03 PT-03

PT-03
12  INTERIOR ELEVATION  11  INTERIOR ELEVATION  10  INTERIOR ELEVATION  9  INTERIOR ELEVATION 
A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0"
PT-03
10655 N.E. 4th Street, Suite 606 |
WC-09 Bellevue, WA 98004

ELEV#2 [email protected]
P:(425) 598-8516
PROJECT INFORMATION:

WC-09
WC-09
ELEVATOR
LOBBY
240
CPT-02 MEDFORD, OR

P
B-02 ELEV#1

Prototype Version 3.0


August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.
WC-04
WC-04
WC-04 1 A1 2022.11.30 ISSUED FOR

WC-09
WC-09
WC-04 WC-04
PERMIT

WC-04
ICE
9' - 1 3/8"

9' - 1 3/8"
243
432 OPEN T-01 B-04

WC-04
4
432
432
FD-02
WC-09 WC-04

B-04 B-04 B-04 B-04

8  INTERIOR ELEVATION  7  INTERIOR ELEVATION  6  INTERIOR ELEVATION  5  INTERIOR ELEVATION  D  FLOOR FINISH PLAN 
A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0" A-311B 1/4" = 1'-0"

CURRENT ISSUE:

ISSUE FOR PERMIT

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES PJ/RG
BASE4 NOTES BASE4 NOTES CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR
NOTED LOCATIONS OF RELATED ITEMS. LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION.

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ENLARGE
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
TYPICAL
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES ELEVATOR
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. LOBBY
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-311B
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:
X-01
X-01 AUDIO/VISUAL
PA-204 PL-01 PT-04 Ricardo J. Muniz-Guillet, AIA
PL-01 FIRE ALARM
PL-01 PT-04 S03 EM PA-204 PA-204 PA-204 2030 Habersham Trce
PL-01 PT-04 PL-01 PT-04 PA-204 PL-01 PT-04 PA-204 PA-204 PT-04 PL-01 PT-04 PL-01 PT-04 PT-04 PL-01
Cumming, GA 30041
X-01
EM WC-10 954.812.6650
WC-10 WC-10 WC-10 WC-10
EM [email protected]
8' - 0"

8' - 0"
100 FEC GR-A GR-A GR-A 144 196B GR-A FEC GR-A GR-A GR-A

6' - 0"
5' - 9"

WC-10

B-02 B-02 B-02 B-02 X1 B-02 B-02

2  INTERIOR ELEVATION  3  INTERIOR ELEVATION  1  INTERIOR ELEVATION 


A-312A 1/4" = 1'-0" A-312A 1/4" = 1'-0" A-312A 1/4" = 1'-0"
1
8 A-807.B 11/30/2022 8:26:01
8:11:47 PM
A-807.A
OWNER:

KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN.
101 103 105 107 101 103 105 107

10655 N.E. 4th Street, Suite 606 |


WC-10 Bellevue, WA 98004
CORRIDOR 1

100 FEC
26' - 2"
2 A-312A CORRIDOR [email protected]
CPT-02 CPT-02 100 P:(425) 598-8516
B-02 A
X1 A 3 PROJECT INFORMATION:
WC-10
P
RF
A
KING ONE KING ONE
BEDROOM KING STUDIO KING STUDIO BEDROOM KING STUDIO KING STUDIO
STAIR#2 STORAGE SUITE SUITE SUITE STAIR#2 STORAGE SUITE SUITE SUITE
196 144 106 108 110 196 144 106 108 110
MEDFORD, OR
9
A-807.A 2
D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN 
A-807.B Prototype Version 3.0
A-312A 1/4" = 1'-0" A-312A 1/4" = 1'-0"
August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.
1 4 5 6
1 A1 2022.11.30 ISSUED FOR
5 1/2" PERMIT
5 1/2" 5' - 11" 2' - 0 1/8" 4' - 2 1/8" 5 1/2" 4' - 2 3/4" 2' - 0 1/8" 5' - 11 1/8" 5' - 11" 2' - 0 1/8" 4' - 2 5/8" 5 1/2" 4' - 2 3/8" 2' - 0 1/8" 5' - 11 1/8"

5 1/2" 5 1/2" 5 1/2" 5 1/2" 5 1/2"

KING STUDIO KING STUDIO KING STUDIO KING STUDIO


SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. G
101 103 105 107
IP-6.1 IF-6.1 IP-6.1 GD-6.1 IP-6.1 IF-6.1
KING STUDIO KING STUDIO KING STUDIO KING STUDIO ER-6.1 IP-6.1
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN.

5 1/2"
FR-4.1 GD-6.1 FR-4.1 FR-4.1
101 103 105 107 FR-4.1 FR-4.1

5 1/2"
GR-A GR-A GR-A GR-A F
7"

2' - 2 7/8" 3' - 0 1/8"


S03 19' - 4" EM PA-204 12' - 11" PA-204 13' - 2 1/2" PA-204 ER-6.1 CR-6.1

5' - 2 1/4"
2' - 6 1/2"

CLEAR
CORRIDOR

5' - 0"
SD
D SD CORRIDOR
14' - 11" 11' - 5" 100 8' - 10 1/2" 8' - 0" 10' - 1 1/2"
100
2' - 6"

R-1
PA-204 EM PA-204 PA-204 PA-204 ER-6.1 ST-6.1 CR-6.1
F

5 1/2"
5 1/2"
RF
196B 144 GR-A GR-A GR-A E
FR-4.1 FR-4.1
IR-6.1
GD-6.1
KING ONE 196A FR-4.1 KING ONE IF-6.1 IP-6.1
BEDROOM KING STUDIO KING STUDIO SH-3.1 BEDROOM KING STUDIO KING STUDIO
STAIR#2 STORAGE SUITE SUITE SUITE STAIR#2 ST-6.1 STORAGE SUITE SUITE SUITE
ST-6.2
196 144 106 108 110 196 144 106 FR-4.1 108 110 CURRENT ISSUE:
SD 1 1/2" 3 1/2" 6 1/4"
5 1/2" 5' - 3 1/2" 5 1/2" 7' - 0 3/4" 8' - 8 3/4" 5 1/2" 2' - 11 3/8" 3' - 0 7/8" 2' - 0 1/8" 2' - 0 5/8" 3' - 5 1/2" 1' - 10 1/8" 5' - 1 1/4" 2' - 0 1/8" 4' - 3" 5 1/2" 4' - 2 3/4"
ISSUE FOR PERMIT
1 1/4" 5 1/2" 3 1/2" 5 1/2" 3 1/2" 5 1/2"
B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN 
A-312A 1/4" = 1'-0" A-312A 1/4" = 1'-0" CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
ENLARGE FIRST
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
FLOOR
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
CORRIDOR
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-312A
0" 1"
MECHANICAL FOOR PREP

1' - 10 1/2"
156 9" 159 MECHANICAL 2901 Clint Moore Rd, #114
156 Boca Raton, FL 33496
3 888.901.8008 www.base-4.com
CR
WC-10 ARCHITECT:
26' - 6" 12' - 7 1/2"
3
CORRIDOR Ricardo J. Muniz-Guillet, AIA
100 2030 Habersham Trce
CORRIDOR A
A-312B 1
A CPT-02 Cumming, GA 30041
100
B-02 954.812.6650
2 WC-10 [email protected]

QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN


QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN
STUDIO SUITE STUDIO SUITE STUDIO SUITE
STUDIO SUITE STUDIO SUITE STUDIO SUITE
120 122 124
120 122 124

D  FLOOR FINISH PLAN 


A-312B 1/4" = 1'-0"
C  FURNITURE AND POWER PLAN 
A-312B 1/4" = 1'-0"

11/30/2022 8:26:01
8:12:04 PM
PL-01 PT-04 OWNER:

WC-10 WC-10
MECHANICAL FOOR PREP
R-1 R-1/E
156 159
D

8' - 0"
EM 8' - 0" OPEN
156
10655 N.E. 4th Street, Suite 606 |
Bellevue, WA 98004

3' - 5"
10' - 0" 5' - 7 1/2"
CORRIDOR
100 D
R-1 R-1/E 6' - 5 1/2"
[email protected]
8' - 0" SD
13' - 2 1/2" 12' - 11 1/2" P:(425) 598-8516
PA-204 B-02 B-02
PA-204 PA-204 PROJECT INFORMATION:
F
3  INTERIOR ELEVATION 
EM
A-312B 1/4" = 1'-0"

QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN


STUDIO SUITE STUDIO SUITE STUDIO SUITE
120 122 124

PA-204 MEDFORD, OR
PL-01 PT-04 PL-01 PT-04 PL-01 PT-04

B  REFLECTED CEILING PLAN 


A-312B WC-10
1/4" = 1'-0" Prototype Version 3.0
PA-204 August 2022

8' - 0"
ISSUE
DELTA ISSUE DATE DESCRIPTION
GR-A GR-A GR-A NO.

6' - 0"
PA-204
1 A1 2022.11.30 ISSUED FOR
11 12 13 14 PERMIT

5 1/2"
3 1/2" 13' - 8 1/2" 5 1/2" 10' - 5 1/2" 2' - 2" 4' - 1 1/2" 7' - 10" 9 1/2" 5 1/2"
B-02

FR-4.1 IR-6.1
GD-6.1 FOOR PREP 2  INTERIOR ELEVATION 
GR-B1 159 A-312B
MECHANICAL 1/4" = 1'-0"
5 1/2"

FR-4.1 156 CR-6.1


5 1/2"

156 F
1' - 11"

CR-6.1
3
5' - 2 1/4"

PL-01 PT-04
CLEAR

A-807.B 154
5' - 0"

CORRIDOR
3' - 3 1/4"

100
FIRE ALARM
CR-6.1 CR-4.1
PA-204
5 1/2"

GR-A GR-A GR-A E


5 1/2"

8' - 0"
FR-4.1 IP-6.1 WC-10
154
GD-6.1
QUEEN QUEEN GD-6.1 QUEEN QUEEN IP-6.1 GD-6.1 IP-6.1 QUEEN QUEEN
STUDIO SUITE STUDIO SUITE STUDIO SUITE IF-6.1 CORRIDOR
120 122 124 100.1
CURRENT ISSUE:
5 1/2"
5' - 11 5/8" 2' - 0 1/8" 4' - 2 1/4" 5 1/2" 4' - 2 3/4" 2' - 0 1/8" 5' - 11 1/8" 5' - 11 5/8" 2' - 0 1/8" 4' - 2 3/4" 5 1/2"
B-02
5 1/2" 5 1/2" 5 1/2" ISSUE FOR PERMIT
5 1/2"

A  CONSTRUCTION PLAN  1  INTERIOR ELEVATION 


CURRENT ISSUE DATE:
A-312B 1/4" = 1'-0" A-312B 1/4" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
ENLARGE FIRST
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
FLOOR
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
CORRIDOR
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-312B
0" 1"
KING STUDIO KING STUDIO KING STUDIO KING STUDIO
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. X-01
201 203 205 207
PA-204

W2 2901 Clint Moore Rd, #114

8' - 0"
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:
3 PT-04
WC-10 Ricardo J. Muniz-Guillet, AIA
2 A-313A
CORRIDOR 2030 Habersham Trce
200 B-02 Cumming, GA 30041
X1 A 954.812.6650
1
P 2 [email protected]
 INTERIOR ELEVATION 
A-313A 1/4" = 1'-0"
7"
KING ONE
BEDROOM KING STUDIO
STAIR#2 STORAGE SUITE SUITE X-01 PA-204 PA-204 PA-204 PA-204
296 206 EM
244 208 PL-01 PT-04 PL-01 PT-04 PL-01 PT-04 PL-01 PT-04

WC-10
C  FURNITURE AND POWER PLAN 
A-313A 1/4" = 1'-0"

8' - 0"
GR-A GR-A GR-A GR-A

5' - 9"
11/30/2022 8:26:01
8:12:22 PM
OWNER:

B-02

KING STUDIO KING STUDIO KING STUDIO KING STUDIO 3  INTERIOR ELEVATION 
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN. A-313A 1/4" = 1'-0"
201 203 205 207
EM
10655 N.E. 4th Street, Suite 606 |
Bellevue, WA 98004
5' - 10 1/2" PA-204 13' - 3 1/2" PA-204 13' - 3" PA-204 12' - 10 1/2" PA-204 PA-204
AUDIO/VISUAL X-01
[email protected]

EQ
X-01 FIRE ALARM
PA-204 PA-204 EM
26' - 6 1/2" SD
8' - 5" 9' - 7" SD PL-01 PT-04 PL-01 PT-04 PL-01 PT-04 P:(425) 598-8516
CORRIDOR

EQ
200 A 10" PROJECT INFORMATION:
PA-204 PA-204
8' - 0" PA-204 WC-10 WC-10 PT-04
F
PL-01

8' - 0"
KING ONE
EM KING STUDIO GR-A GR-A 244 296
BEDROOM
STAIR#2 SUITE
STORAGE SUITE
296 208 X1
244 206

MEDFORD, OR

B-02 B-02
B  REFLECTED CEILING PLAN  Prototype Version 3.0
A-313A 1/4" = 1'-0"
1  INTERIOR ELEVATION  August 2022
A-313A 1/4" = 1'-0"
1 4 5 6 ISSUE
5 1/2" 5 1/2" DELTA ISSUE DATE DESCRIPTION
NO.
5 1/2" 5 1/2" 5 1/2"
5 1/2" 8' - 4 5/8" 4' - 2 1/8" 5 1/2" 4' - 2 3/4" 2' - 0 1/8" 5' - 11 1/8" 5' - 11" 2' - 0 1/8" 4' - 2 5/8" 5 1/2" 4' - 2 3/8" 2' - 0 1/8" 5' - 11 1/8"
1 A1 2022.11.30 ISSUED FOR
PERMIT
H
ER-6.1
KING STUDIO KING STUDIO KING STUDIO KING STUDIO
GR-B SUITE CONN. SUITE CONN. GR-B GR-B SUITE CONN. SUITE CONN. GR-B KING STUDIO KING STUDIO KING STUDIO KING STUDIO
SUITE CONN. SUITE CONN. SUITE CONN. SUITE CONN.
201 203 205 207
201 203 205 207

IP-6.1 GD-6.1 IP-6.1 FR-4.1 FR-4.1 GD-6.1 IP-6.1 FR-4.1


5 1/2"

FR-4.1 IF-6.1 IP-6.1 IF-6.1

5 1/2"
GR-A GR-A GR-A GR-A F
2' - 7 7/8" 2' - 7 1/8"

CR-6.1 WC-10
CORRIDOR

5' - 2 1/4"
200
CLEAR
5' - 0"

CORRIDOR
W2 CPT-02
200
B-02
ST-6.1 CR-6.1
WC-10
5 1/2"
296 244 GR-A GR-A E
5 1/2"

FR-4.1
SH-3.1
FR-4.1 IR-6.1 KING ONE
KING ONE FR-4.1 IF-6.1 IP-6.1 GD-6.1
KING STUDIO STAIR#2 BEDROOM KING STUDIO
ST-6.1 SH-3.1 BEDROOM
ST-6.2 STAIR#2 FR-4.1 STORAGE SUITE SUITE
STORAGE SUITE SUITE 296
296 244 206 208 244 206 208 CURRENT ISSUE:
FR-4.1
1 1/2" 3 1/2"
5 1/2" 1' - 11" 19' - 7 1/2" 5 1/2" 2' - 11 3/8" 3' - 2" 1' - 11" 2' - 0 5/8" 3' - 5 1/2" 1' - 10 1/8" 5' - 11" 2' - 0 1/8" 4' - 3" 5 1/2"
ISSUE FOR PERMIT
1 1/4" 5 1/2" 3 1/2" 5 1/2" 5 1/2"
A  CONSTRUCTION PLAN  D  FLOOR FINISH PLAN 
A-313A A-313A CURRENT ISSUE DATE:
1/4" = 1'-0" 1/4" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
ENLARGE
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
TYPICAL FLOOR
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
CORRIDOR
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-313A
0" 1"
X1

X-01
RF
P
FES
W2 2901 Clint Moore Rd, #114
PA-204 Boca Raton, FL 33496

8' - 0"
888.901.8008 www.base-4.com
ARCHITECT:
3
Ricardo J. Muniz-Guillet, AIA
A-313B 2 CORRIDOR WC-10 2030 Habersham Trce
200 Cumming, GA 30041
26' - 4 7/8" 8' - 1 1/8" 8' - 6 1/2"
1
B-02 954.812.6650
A [email protected]
2  INTERIOR ELEVATION 
A-313B 1/4" = 1'-0"

PA-204 X-01
EM AUDIO/VISUAL
PA-204 FIRE ALARM
PL-01 PT-04 PL-01 PT-04 PL-01 PT-04 PL-01 PT-04

WC-10
WC-10
WC-10
C  FURNITURE AND POWER PLAN 
A-313B 1/4" = 1'-0"

8' - 0"
OPEN
GR-A GR-A 240

X1 11/30/2022
2022-11-308:26:01 PM
23:24:19
OWNER:
STAIR#1
B-02 B-02 B-02 B-02 B-02

F
QUEEN QUEEN QUEEN QUEEN ELEVATOR 3  INTERIOR ELEVATION 
ICE
STUDIO SUITE STUDIO SUITE LOBBY A-313B 1/4" = 1'-0"
CORRIDOR
200 10655 N.E. 4th Street, Suite 606 |
Bellevue, WA 98004

2' - 2"
PA-204 13' - 3 1/2" 6' - 5 1/2" EM 14' - 11 1/2" 14' - 8"

A X-01 EM [email protected]
SD PA-204 SD PA-204 PL-01 PT-04 PL-01 PT-04 PL-01 PT-04 PL-01 PT-04 P:(425) 598-8516
12' - 10 1/2" 13' - 3 1/2" 8' - 0" 14' - 5" 8' - 6 1/2"

2' - 10"
PROJECT INFORMATION:
PA-204 PA-204 CORRIDOR PA-204 EM PA-204 WC-10
PA-204 PA-204 PA-204
QUEEN QUEEN
QUEEN QUEEN

8' - 0"
STUDIO SUITE-
QUEEN QUEEN QUEEN QUEEN STUDIO SUITE
ACC. GR-A1 GR-A GR-A GR-A
STUDIO SUITE STUDIO SUITE CONN.

5' - 9"
CONN.(RIS)

1' - 6"
OS MEDFORD, OR

B-02 B-02 B-02 B-02


B  REFLECTED CEILING PLAN 
A-313B
Prototype Version 3.0
1/4" = 1'-0"
August 2022
1  INTERIOR ELEVATION 
ISSUE
A-313B 1/4" = 1'-0" DELTA ISSUE DATE DESCRIPTION
20 21 22 25 26 NO.
1 1/4" 1 1/2"
5 1/2" 5' - 11 1/8" 5' - 11 5/8" 2' - 0 1/8" 4' - 2 1/4" 2' - 11 3/8" 3' - 0 1/8" 3' - 0 7/8" 5 1/2" 6' - 2 1/4" 2' - 1 1/4" 5' - 6 7/8" 2' - 8" 5 1/2" 1 A1 2022.11.30 ISSUED FOR
PERMIT
5 1/2" 5 1/2" 5 1/2" 3 1/2" 3 1/2" 1' - 7 3/4" 5 1/2" 3 1/2" 1 1/2" 1 7/8"

GR-B GR-B QUEEN QUEEN FR-4.1 FR-4.1 ST-6.1 STAIR#1 STAIR#1


QUEEN QUEEN ELEVATOR
STUDIO SUITE ELEVATOR 295 RF 295 RF
STUDIO SUITE LOBBY ICE
233 FR-4.1 LOBBY IR-6.1 ICE G
233 240 243
240 243
CT-01

1 1/2"
IP-6.1 FR-4.1 FR-4.1 SH-3.1 T-01

1 1/4"
GD-6.1 IP-6.1 GD-6.1 CR-6.2 FR-4.1 B-02
5 1/2"

GR-A GR-A 240 X FR-4.1 ER-6.1 F

3 1/2"
CR-6.1 WC-10

5' - 10 3/4"
CORRIDOR
5' - 2 1/4"

CORRIDOR 2
CLEAR

200
5' - 0"

2 W2 A-804
200 A-806 CPT-02
5 1/2" B-02
CR-6.1 WC-10
5 1/2"

GR-A GR-A GR-A GR-A1 E


3 1/2" 1' - 11 1/4"

QUEEN QUEEN
GD-6.1 GD-6.1 IP-6.1 GD-6.1 QUEEN QUEEN QUEEN QUEEN STUDIO SUITE-
QUEEN QUEEN STUDIO SUITE- FR-4.1
QUEEN QUEEN QUEEN QUEEN IP-4.1 QUEEN QUEEN QUEEN QUEEN STUDIO SUITE ACC.
IP-6.1 FR-4.1 FR-4.1 STUDIO SUITE ACC. STUDIO SUITE STUDIO SUITE CONN. CONN.(RIS)
IP-6.1 STUDIO SUITE STUDIO SUITE
CONN. CONN.(RIS)
232 234 ER-6.1 232 234 236 238
236 238
5 1/2" CURRENT ISSUE:
2' - 0 1/8" 4' - 2 1/4" 5 1/2" 4' - 2 3/4" 2' - 0 1/8" 5' - 11 1/8" 5 1/2" 5' - 11 5/8" 2' - 0 1/8" 4' - 2 7/8" 5 1/2" 4' - 3 7/8" 3' - 2 1/8" 5' - 3 1/2" 2' - 7 3/8" 5 1/2"

5 1/2" 5 1/2" 3 1/2" 3 1/2" 3 1/2" 1 1/4"


ISSUE FOR PERMIT
A  CONSTRUCTION PLAN  D  FLOOR FINISH PLAN 
A-313B 1/4" = 1'-0" A-313B 1/4" = 1'-0" CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
ENLARGE
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
TYPICAL FLOOR
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
CORRIDOR
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH KEY PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-313B
0" 1"
PT-03 GR-205 GR-205 NOTE- CUTAINS TO HAVE
PT-02 LONG DRAPES WC-11
PL-01
AUDIO/VISUAL FIRE ALARM
PT-03 11 901 GR-400
PT-04 PT-02 PT-03 GR-500
GR-500 GR-208
GR-504 GR-201
903 33 4' - 3 3/4" 39

9' - 1 5/8"

9' - 1 5/8"

9' - 1 5/8"
40 GR-301
12 6"

1' - 4"
44 28 24 41 2901 Clint Moore Rd, #114
7' - 3"

7' - 3"
11"

7' - 3"
Boca Raton, FL 33496

6' - 6"
GR-A1 GR-C GR-B1

5' - 6"

3' - 11 7/8"
904 888.901.8008 www.base-4.com

4' - 3"
3' - 7 1/2"

4' - 4"

4' - 4"
3' - 10"

3' - 10"

4' - 0"

4' - 0"
1

MAX.

3' - 6"

3' - 2"

1' - 0"
3' - 4"

3' - 4"
ARCHITECT:

OPEN Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce

1' - 9"
GR-304 GR-104 B-01 GR-105 GR-101 GR-200 GR-405 GR-307 GR-104 18" MIN. B-01 902 B-01 GR-504 GR-200 GR-101 904 GR-317 B-01
GR-207 GR-601 Cumming, GA 30041
12
A-408
GR-318 GR-105 GR-205 GR-317 GR-607 954.812.6650
1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  4  INTERIOR ELEVATION  GR-603.ADA
[email protected]
A-400 1/4" = 1'-0" A-400 1/4" = 1'-0" A-400 1/4" = 1'-0"
PT-01
GR-400

AUDIO/VISUAL
FIRE ALARM
9' - 1 5/8"

6" 6"
GR-208
W1
4
35
904 GR-201
1

GR-304
11/30/2022 8:26:01
8:15:37 PM
2"

GR-317 GR-607 B-01 OWNER:


GR-601 GR-603.ADA A
24 A-450 26
3  INTERIOR ELEVATION  3 1/2" 3 1/2"
A-400 1/4" = 1'-0" 5 1/2" 4' - 3 7/8" 3' - 2 1/8" 5' - 3 1/2" 3' - 0 1/8" 5 1/2"

5 1/2"
901
29

1' - 0"

5 1/2"
GR-A1 E 10655 N.E. 4th Street, Suite 606 |

1' - 11 1/4"
2' - 0" 2' - 2 1/2" Bellevue, WA 98004

2' - 0"
PT-03 WC-12 B

2' - 10"
B CR-6.1 FR-4.1

2' - 11 1/2"
R-1

11"
A-450 IP-4.1
A R-1 R-1
[email protected]

3 1/2"
SS-01 2' - 7"

2' - 6"
11 R-3 FR-4.1 P:(425) 598-8516
B
PT-03

18

5' - 1 1/4"
9' - 8 3/8"
31 GR-B1

1' - 4"
1' - 2"

CLEAR
7' - 3" PROJECT INFORMATION:
T-01 T-01 7 GR-313 FR-4.1

4' - 8"
OS

11' - 9 3/8"
B
PT-07

2' - 6"
B-01 B-05
902 19 EQ EQ
WC-12

FR-4.1
SS-01 R-1 31
R-1
PT-03

1' - 10 5/8"
10"
4 1/2"
3 1/2"

4" 7' - 4 1/4"

1' - 0"
7' - 3"

1' - 6"

3 1/2"
IP-4.1 FR-4.1

J
WC-12 PT-07

T
33
D

10"

7"
PT-03 EQ EQ
MEDFORD, OR

3 1/2"
48 GR-504 12 32 GR-318
21 GR-C
GR-200
A B Prototype Version 3.0
8' - 0"

8' - 10"
GR-500 August 2022

8' - 5"
CPT-07
KING SUITE
38 ACC. H GR-105 ISSUE
CONN.(TUB) DELTA ISSUE DATE DESCRIPTION
33 NO.
1' - 0 1/2"

GR-101
1' - 2"

4' - 4" ER-6.1 1 A1 2022.11.30 ISSUED FOR


GD-6.1
PERMIT
8' - 0" GR-104 M
GR-205

1' - 1"
22 WAP

3' - 9 1/2"
2' - 2 1/2"
8 1/2"

GR-201 OS
KING SUITE
GR-208 ACC. 8
CONN.(TUB)
6"

26' - 1 5/8"

26' - 2 7/8"
H GR-317

CLEAR
32 KING SUITE
F

3"

24' - 3 1/4"
KING SUITE 904 ACC.
2 A-400 4 9' - 1 5/8" 31
ACC. CONN.(TUB)

520
SD
4' - 1 1/2"

CONN.(TUB) 903 PT-07


3
CPT-01 FLOOR FINISH
WC-11
PT-03

H GR-601

7' - 10"
B-01 BASE FINISH
GR-607
GR-207 GR-603.ADA
GR-301
9' - 0 1/2"

7' - 4 1/4" 8' - 10 1/8"

GR-307
904

1' - 7 1/2"
GR-208 16' - 2 3/8"
32 GR-317
CLEAR
WORKING WALL INSTALLATION: 1
30 LAYOUT AND CONSTRUCTION IS
H
3' - 7"

TO START AT REFRIGERATOR GR-405 GR-400


HOLD DIMENSION AND PROCEED
PT-01 UP THE WALL FROM THAT END- ER-6.2
J

5 1/2"

5 1/2"
FINAL INSTALLATION IS ROD AT J CURRENT ISSUE:
CLOSET. TO BE SCRIBED AT WALL A
AS REQUIRED
W1
3' - 7 1/2" 6' - 0"
5 1/2" 6' - 2 1/8" 10' - 2 1/2" 5 1/2"
ISSUE FOR PERMIT
D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN  CURRENT ISSUE DATE:
A-400 1/4" = 1'-0" A-400 1/4" = 1'-0" A-400 1/4" = 1'-0" A-400 1/4" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE
GUESTROOM -
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
ACC. KING
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
SUITE
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD CONN.(TUB)
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-400
0" 1"
AUDIO
VISUAL FIRE
ALARM GR-400
PT-01 PT-02 PT-03 903

GR-400 GR-206 901


901 902 PT-03 PL-01 PT-04
30 30 4 50
2" 1' - 4"
6" 6"

9' - 1 3/8"
14

9' - 1 1/2"
11 6"
PT-01 PT-01 903
W1 GR-205 2901 Clint Moore Rd, #114
FULL TILE
8' - 0" Boca Raton, FL 33496

7' - 3"

7' - 3"
11"
GR-200 35 47 33
GR-500 40 GR-C 888.901.8008 www.base-4.com

5' - 6"
GR-A1
4 SQUARES

WC-11
PT-03

3' - 10"
ST-01 GR-200

3' - 8"

MAX
ARCHITECT:

MAX
3' - 4"

3' - 4"

3' - 4"
3' - 0"
22
CPT-07 21 GR-101

1' - 6"
Ricardo J. Muniz-Guillet, AIA

1' - 0"
2030 Habersham Trce
38 4 SQUARES CPT-01 1 GR-102 Cumming, GA 30041
KING ONE GR-201 1 B-01 10 25 B-01 GR-104 TYP B-01
954.812.6650
8' - 0"

BEDROOM B-01 GR-104 GR-105 GR-304 GR-201 GR-319


SUITE GR-304 [email protected]
11
ACC(TUB) REFER TO PRODUCT SPECIFICATIONS
FOR CARPET INSTALLATION PATTERN A-408
PT-03

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION 


A-401 1/4" = 1'-0" A-401 1/4" = 1'-0" A-401 1/4" = 1'-0"

CPT-01 FLOOR FINISH GR-400


B-01 BASE FINISH
WC-11 GR-205 PT-12 WC-11 PT-02 PT-03 FIRE ALARM
GR-500 PT-01
4 1/8"

GR-400
PT-03 GR-206 WC-11 PT-12
12
FULL TILE

39 GR-406
WC-12
6" 6" 903

9' - 1 3/8"

9' - 1 3/8"

9' - 1 3/8"
SS-01 41 24 6"
WC-12

903

7' - 0"
7' - 3"
GR-D GR-B1 GR-301

SS-01

6' - 6"
47
7
W1 GR-D 11/30/2022 8:26:01
8:16:03 PM

5' - 0"
T-01 T-01 904

3' - 11"
4' - 0"
GR-504

3' - 4"
OWNER:
B-01 B-05 GR-317
SS-01

1' - 0"
GR-400

TYP GR-102 B-01 B-01 41 B-01 GR-316 GR-406


PT-03 WC-12 GR-205 GR-200
GR-319
GR-101 GR-318 GR-403
29
10655 N.E. 4th Street, Suite 606 |
4  INTERIOR ELEVATION  5  INTERIOR ELEVATION  6  INTERIOR ELEVATION  Bellevue, WA 98004
A-401 1/4" = 1'-0" A-401 1/4" = 1'-0" A-401 1/4" = 1'-0"
[email protected]
D  FLOOR FINISH PLAN  P:(425) 598-8516
A-401 1/4" = 1'-0"
PROJECT INFORMATION:
PT-03 PT-02

10 11 12
GR-205
GR-201 PTAC UNIT 5 1/2" 5' - 9 3/8" 5' - 11 1/4" 3 1/2" 13' - 8 3/8" 5 1/2"
GR-406
5' - 8 1/2" 35 4' - 8" 3' - 9 1/2" 1 12 903
GR-400 W1 W1 905

9' - 1 3/8"
5 1/2"

5 1/2"
J 24
J J J J
10 1/2"
7" 1' - 7"

30 30 GR-B1 MEDFORD, OR
2' - 10"

2' - 10"

ER-6.1
3' - 1"

ER-6.1
3' - 1"

IP-4.1
3"

4' - 2 3/4"
4
1 GR-317 11' - 6 3/4" 13' - 6 1/2"
WAP
44 45 GR-400
46 45 GR-104
H GR-202 Prototype Version 3.0
KING ONE CLEAR CLEAR
GR-316 August 2022
6" 3' - 0 1/2"

GR-304 GR-101 BEDROOM


33
4' - 1"

904 SUITE GR-607


GR-500 B-01 GR-316 ISSUE
ACC(TUB)

13' - 0 1/4"
5 DELTA ISSUE DATE DESCRIPTION

12' - 10"
GR-105 GR-601 IF-6.1 GD-6.1 GR-301 GR-603.ADA GR-504 NO.
7' - 8 1/2"

31

23' - 9 1/8"

15' - 4 1/8"
15' - 2 3/8"

15' - 2 3/8"
47 GR-603.ADA 31 GR-601

CLEAR

CLEAR
6 A-401 8
3' - 1 1/2" 6"

OS OSF 1 A1 2022.11.30 ISSUED FOR


1' - 1 1/2" 3' - 4 1/2"

903 GR-607 F 9' - 1 3/8" PERMIT


9' - 1 3/8"
520
SD

1 7 GR-301 PT-07 7  INTERIOR ELEVATION 


35 903 32
H PT-07 A-401 1/4" = 1'-0"
905

520
SD
2 A-401 4
1' - 8"

GR-316 B
9"

GR-202
2' - 0"

3
GR-318 GR-200 GR-317
KING ONE GR-D
GR-C
KING ONE 32 12 48 BEDROOM
2' - 5"

2' - 5"

5 1/2"
GR-504
BEDROOM 6' - 0" SUITE WC-11
SUITE ACC(TUB)
7 1/2"

33 T GR-400
ACC(TUB) GR-B1
1' - 1"

GR-102
3
B

7"
A 19
J

1' - 1" A-451 R-1 6' - 0" 1' - 5"


902 R-1
1' - 2"

31
3' - 4"

GR-206 EQ EQ

10' - 11 1/8"

3 1/2"
10' - 11 1/4"
J
4"
4"

4' - 8"

IP-4.1 IP-6.1 FR-4.1


B
6"

2' - 1" 4' - 4" GR-202

EQ

5' - 1 1/4"
7' - 3" 18

9' - 1 3/8"
9' - 3"
I M 31 GR-301 12
FR-4.1
1' - 9"

GR-102
1' - 6"

PT-07

CLEAR
8' - 0"
B R-1
4' - 5"

H OS A

EQ
GR-319

3 1/2"
5
3

40 11 7' - 3"
4' - 7 1/2"

R-1 R-1 R-3 FR-4.1


1' - 4 1/2"

R-1
3' - 5 1/2"

R-1
2' - 5"

PT-07 1 905

4' - 4"
2' - 1 1/2"

3' - 1 1/8"
3 GR-B1 A

1' - 10 5/8"
CR-6.1
2' - 0"

A-806 2' - 2 1/2" A-451


A

1' - 6"
B FR-4.1
1' - 0"

2' - 0" 2' - 11"

5 1/2"
GR-A1 F
904 GR-601 GR-504

5 1/2"
4' - 7 1/2" B-01
901 A 5 1/2" 5' - 0 1/4" 6' - 8 3/8" 3 1/2" 10' - 0 1/8" 3 1/2" 3' - 4 3/4" 5 1/2" GR-607 GR-317 CURRENT ISSUE:
GR-317
WORKING WALL INSTALLATION:
LAYOUT AND CONSTRUCTION IS GR-603.ADA
TO START AT REFRIGERATOR
HOLD DIMENSION AND PROCEED ISSUE FOR PERMIT
UP THE WALL FROM THAT END-
C  FURNITURE AND POWER PLAN  FINAL INSTALLATION IS ROD AT
B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN  8  INTERIOR ELEVATION 
A-401 1/4" = 1'-0" CLOSET. TO BE SCRIBED AT WALL A-401 1/4" = 1'-0" A-401 1/4" = 1'-0" A-401 1/4" = 1'-0"
AS REQUIRED CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
GUESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
ACC. KING ONE
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
BEDROOM(TUB)
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:
A CEILING FINISH
9'-6" CEILING HEIGHT

A-401
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:
GR-400
Ricardo J. Muniz-Guillet, AIA
2030 Habersham Trce
GR-400 Cumming, GA 30041
PT-03 GR-207 FIRE ALARM GR-201 PT-02 PT-03 PT-03 901 PT-01 GR-200 GR-205 GR-208 GR-208 GR-208 954.812.6650
GR-405 GR-307 GR-500 WC-11
[email protected]
PT-03 901 PL-01 PT-04 PT-02 PT-03
GR-504 GR-500
903

7' - 0"
4" GR-404 904
12 GR-405 GR-504 39
4 905 GR-300

10 1/2"
9' - 1 1/2"

9' - 1 1/2"

9' - 1 1/2"

9' - 1 1/2"
44 33 40 35

1' - 4"
903 41
7' - 3"

7' - 3"

7' - 3"
6' - 10"

GR-606
GR-A1 GR-C W1 GR-B1

5' - 6"
GR-201

5' - 0"
1

1' - 0"
3' - 5 1/2"
3' - 10"

4' - 0"

4' - 0"

4' - 0"
MAX.

3' - 6"

3' - 4"

3' - 4"
3' - 0"
GR-304

1' - 0"
1' - 9"

2"
44 46 GR-104

1' - 0"
GR-304 B-01 GR-105 GR-101 B-01 45 45 B-01 B-01 GR-318 GR-105 GR-317 1
GR-205 GR-309 GR-304 902 GR-404 GR-602.ADA GR-322 GR-600
GR-104 GR-101 GR-602.ADA
GR-200 GR-606 GR-317
GR-600 GR-606 11/30/2022 8:26:01
8:16:21 PM
GR-600
GR-602.ADA
OWNER:

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION  4  INTERIOR ELEVATION 


A-402 1/4" = 1'-0" A-402 1/4" = 1'-0" A-402 1/4" = 1'-0" A-402 1/4" = 1'-0"

10655 N.E. 4th Street, Suite 606 |


Bellevue, WA 98004
24 A. 26
A-450 [email protected]
31 A B 31
7' - 3" 7' - 3" 3 1/2" 3 1/2" P:(425) 598-8516
5 1/2" 4' - 3 7/8" 3' - 2 1/8" 5' - 3 1/2" 3' - 0 1/8" 5 1/2"

1' - 2"

5 1/2"
PT-07 PT-07 PROJECT INFORMATION:

1' - 0"
FR-4.1

5 1/2"

1' - 11 1/4"
GR-A1 E

10"
PT-03 EQ EQ

2' - 10"
WC-12 FR-4.1
1' - 5 3/4" 2' - 11"
901 2' - 0" 2' - 2 3/4" CR-6.1
IP-4.1

2' - 0"

3 1/2"
9"
1' - 2" 40 R-1 EQ EQ FR-4.1
SS-01

EQ
4' - 4"

9' - 4 1/4"

5' - 3 1/4"
18

CLEAR
GR-B1

CLEAR
5' - 2"
R-1 R-1 OS 19

11' - 8 7/8"
B

4' - 8"
T-01 T-01 7 A
B.
R-1

2' - 2"

3 1/2"
CT-07

EQ
B-01 902 A-450 R-1 R-3 MEDFORD, OR
WC-12
PT-03

SS-01 FR-4.1
2 1/4"

1' - 8 5/8"
1' - 6"
IP-4.1
J
EQ EQ FR-4.1

1' - 0"
WC-12

T
GR-101
10 1/8"
6 1/8"

48 33
D Prototype Version 3.0

1' - 0"

3 1/2"
PT-03 B August 2022
4 SQUARES

GR-504 32 GR-318 GR-C


9 12
8' - 0"

H ISSUE
GR-200 DELTA ISSUE DATE DESCRIPTION
37 NO.
7' - 4 1/4" 8' - 10 1/8"

7' - 0"
22 GR-500
GR-105 5 1 A1 2022.11.30 ISSUED FOR
CLEAR CLEAR
38 CPT-07 M GR-205 PERMIT
1' - 2"

13 GR-101 4' - 4"

35' - 10"
6"

GR-104 GR-317 A-300A

1' - 10"

1' - 1"
1
8' - 0" 21 WAP GR-208 GD-6.1 ER-6.1
FULL TILE GR-404
8
2' - 4"

4 SQUARES 2 A-402 4 GR-600


GR-201
6"

26' - 2 7/8"
WC-11

GR-606
PT-03

CLEAR
26' - 1"
3

24' - 3 5/8"
QUEEN QUEEN

7' - 6"
QUEEN QUEEN GR-602.ADA OS
QUEEN QUEEN STUDIO SUITE-
H

520

520
4' - 8 3/4"

SD

SD
STUDIO SUITE- 903 32 STUDIO SUITE- ACC.
ACC. GR-300 ACC.
GR-309 CONN.(RIS)
CONN.(RIS) QUEEN QUEEN GR-322 CONN.(RIS)
STUDIO SUITE-
31

4 1/2"
CPT-01 GR-207 ACC. 905 GR-208
FLOOR FINISH H
CONN.(RIS) F
B-01 BASE FINISH 9' - 1 5/8"
GR-307 904
7' - 1 1/2"

32 PT-07
8' - 8 1/4"

GR-300
H 16' - 2 3/8"
GR-602.ADA
CLEAR
GR-405 GR-606
1
30 6' - 1 1/4" 4 GR-600 ER-6.2
1' - 3"

PT-01 32 W1
J

5 1/2"

5 1/2"
GR-317
J
WORKING WALL INSTALLATION:
A
GR-208
LAYOUT AND CONSTRUCTION IS
4 3/4" 5 1/2" 6' - 2 1/8" 10' - 2 1/2" 5 1/2"
TO START AT REFRIGERATOR
HOLD DIMENSION AND GR-400
CURRENT ISSUE:
PROCEED UP THE WALL FROM
THAT END-FINAL INSTALLATION
IS ROD AT CLOSET. TO BE
D  FLOOR FINISH PLAN  SCRIBED AT WALL AS REQUIRED C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN  ISSUE FOR PERMIT
A-402 3/16" = 1'-0" A-402 3/16" = 1'-0" A-402 3/16" = 1'-0" A-402 3/16" = 1'-0"

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE
GUESTROOM
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
-DOUBLE
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
QUEEN STUDIO
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD ACC. CONN.(RIS)
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-402
0" 1"
GR-400

GR-400
WC-11 PT-01

29 PT-03 GR-206 PT-04 PL-01 PT-03 GR-206


PT-12 PT-12 PT-03
5' - 1"
PT-03 GR-405 GR-205
39 6" 6"

9' - 1 3/8"

9' - 1 3/8"
W1
903 GR-500
41 2901 Clint Moore Rd, #114

7' - 3"

7' - 3"
GR-201
GR-A GR-A GR-B ST-02 GR-200 Boca Raton, FL 33496

5' - 0"
PT-03 901 888.901.8008 www.base-4.com

4' - 0"
GR-304 GR-101 ARCHITECT:

GR-318 Ricardo J. Muniz-Guillet, AIA


B-01 GR-101 GR-318 B-01 GR-102 GR-319 GR-304 B-01 GR-105 2030 Habersham Trce
GR-102 GR-319 GR-205 GR-200 41
TYP
Cumming, GA 30041
GR-500 TYP GR-104
954.812.6650
[email protected]
WC-12 PT-03 1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION 

PT-03
A-403 A-403 A-403

WC-12
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
SS-01

FULL TILE
T-01 T-01
SS-01

7 903 FIRE ALARM PT-03 WC-11


GR-400
B-05 B-01

PT-03
11 PT-03 PT-02
SS-01 WC-12

4' - 2" 6"

7' - 0"
PT-03 KING ONE 47 903 GR-202
6"
BEDROOM
GR-202

9' - 1 3/8"

9' - 1 3/8"
SUITE 33 12 GR-301

1' - 4"
CPT-01 CPT-01 FLOOR FINISH

7' - 3"

6' - 10"
WC-11

6' - 7"
GR-B

9' - 1 3/8"
B-01 B-01 BASE FINISH

5' - 0"

4' - 6"
GR-202

4' - 0"
3' - 8"
905

3' - 6"

3' - 6"

3' - 6"
OPEN

3' - 4"
22 GR-315 11/30/2022 8:26:01
8:16:46 PM

1' - 9"
38

1' - 6"
WC-11

44 46 GR-317 OWNER:
21

4 SQUARES
B-01 GR-405 45 45 GR-301 GR-603 GR-601 B-01 41 GR-601 B-01
901 GR-201 GR-304
8' - 0"
1
GR-601.1 GR-317 GR-601.1
905
CPT-07
904
PT-03

GR-603
4  INTERIOR ELEVATION 
A-403 1/4" = 1'-0"
30 30 5  INTERIOR ELEVATION  6  INTERIOR ELEVATION  10655 N.E. 4th Street, Suite 606 |
PT-01 PT-01 A-403 A-403 Bellevue, WA 98004
1/4" = 1'-0" 1/4" = 1'-0"

8' - 0" 2 5 [email protected]


P:(425) 598-8516
4 SQUARES 5 1/2"
D 1' - 10 1/8" 5 1/2" PROJECT INFORMATION:
 FLOOR FINISH PLAN  5 1/2" 12' - 1 3/4" 3 1/2" 5' - 5 1/8" 2' - 0 5/8" 3' - 5 1/2"

5 1/2"
A-403 1/4" = 1'-0"
3 1/2" GR-400
PT-01
GR-A E

3' - 2 3/4"
2' - 4"
9 1/2"

2' - 8"
7" CR-6.1 903

R-1

3 1/2"

9' - 1 3/8"
6" 6" MEDFORD, OR

4' - 0"
FR-4.1 W1
GR-405
R-1
B ST-02 GR-301
A Prototype Version 3.0
6 1/2" 9 1/2"

A-453 A-453 GR-315


IR-6.1 August 2022
GR-319 T 901 904
OS
2' - 0" ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.
2' - 9"

3"
2' - 2" B-01 GR-601

3 1/2"
11 IP-4.1 1 A1 2022.11.30 ISSUED FOR
2' - 0"

R-1 2' - 10" GR-601.1 PERMIT


R-1
3

FR-4.1 FR-6.1
2' - 6"

EQ

4' - 8"
18 GR-603
7 1/2"

5' - 1 1/4"
J

1' - 7"

902 19
9"

3' - 5 1/2"
KING ONE A R-1

29' - 0 7/8"
B 7' - 3" GR-B

CLEAR
5 BEDROOM 7' - 3" 31
31
EQ
2' - 11 1/2"

IP-4.1

1' - 5 1/2"
GR-102 SUITE ER-6.1 7  INTERIOR ELEVATION 
3"

4' - 2 1/8"
1' - 5 1/2" PT-07 PT-07

3 1/2"
3 902 GR-B A-403 1/4" = 1'-0"

25' - 9"
T 1 3' - 0 1/2"
2' - 0"

GR-201 KING ONE


BEDROOM
GR-208 2' - 8 1/2" 2 A-403 4 WAP
GR-A SUITE
905 GR-200 KING ONE
11"

903 BEDROOM
10"
8"

SUITE
10 1/2"

GR-317 GR-315 3
GR-104 F F 31 PT-02 FIRE ALARM PT-03
GR-301
2' - 6"

GR-318 31 9' - 1 3/8"


9' - 1 3/8"
520

SD

GR-601.1 GR-304

13' - 1 3/4"
ER-6.1 IP-4.1
6"

5 PT-07 PT-07
4 1/2"

GR-601 33 OS OS
GR-500

11' - 1"
GR-603 6 A-403 8

520
32

SD
GR-105 903 903
904 IF-6.1

9' - 1 3/8"
7
6' - 3 1/2"

12' - 0" 13' - 4 1/2"


6"
GR-202 4
1' - 9"

CLEAR CLEAR

6' - 6"
3' - 1 1/2"

6' - 9" GR-A


GR-400
2' - 0 1/2"

GR-317

4' - 0"
1 4 ER-6.1 ER-6.1
W1 W1

5 1/2"

5 1/2"
CURRENT ISSUE:
J J
C
5' - 6 1/2" GR-400 5 1/2" 6' - 0 1/8" 6' - 1 5/8" 3 1/2" 13' - 6 3/8" 5 1/2"

1' - 0"
GR-406 GR-205 1 WORKING WALL INSTALLATION: GR-405
LAYOUT AND CONSTRUCTION IS TO
B-01
ISSUE FOR PERMIT
GR-101 START AT REFRIGERATOR HOLD
DIMENSION AND PROCEED UP THE
C WALL FROM THAT END-FINAL B A 8
 FURNITURE AND POWER PLAN  INSTALLATION IS ROD AT CLOSET. TO
 REFLECTED CEILING PLAN   CONSTRUCTION PLAN   INTERIOR ELEVATION  CURRENT ISSUE DATE:
A-403 1/4" = 1'-0" BE SCRIBED AT WALL AS REQUIRED A-403 1/4" = 1'-0" A-403 1/4" = 1'-0" A-403 1/4" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
GUESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
KING ONE
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
BEDROOM
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN A CEILING FINISH
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS 9'-6" CEILING HEIGHT SHEET NUMBER:

A-403
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:
GR-400 GR-400
Ricardo J. Muniz-Guillet, AIA
GR-204
GR-400 2030 Habersham Trce
PT-03 PL-01 PT-04 GR-504 PT-03 GR-405 903 PT-03 FIRE ALARM GR-204 WC-11 GR-500
PT-01
GR-404
Cumming, GA 30041
6" 4' - 4" 954.812.6650
GR-201
PT-03 4 PT-03 PT-02 GR-504 [email protected]
12 GR-301
39
11

7' - 0"
GR-205 GR-200 GR-205 GR-301
6" 6" GR-208

9' - 1 3/8"

9' - 1 3/8"

9' - 1 3/8"

9' - 1 3/8"
33 41
6" W1
GR-400

6' - 7"
6" GR-208

6' - 7"
7' - 3"

7' - 3"
44
6' - 10"

GR-201

6' - 6"
GR-A GR-B GR-208

5' - 6"
ST-02 904

4' - 4"
GR-500

4' - 0"

4' - 0"
5' - 6"
905

3' - 6"

3' - 6"

1' - 6"
3' - 0"
1
44 46

1' - 0"

1' - 0"
1' - 0"
GR-105 B-01 45 45 GR-304
903 GR-104 GR-307 B-01 GR-317 GR-601.1 GR-601 1 B-01 B-01 GR-318 GR-101 GR-105 GR-317 GR-603 GR-601 GR-317 B-01
GR-200
GR-304 GR-101 GR-603 GR-601.1 905

11/30/2022 8:26:01
8:17:05 PM
OWNER:
1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION  4  INTERIOR ELEVATION 
A-404 1/4" = 1'-0" A-404 1/4" = 1'-0" A-404 1/4" = 1'-0" A-404 1/4" = 1'-0"

10655 N.E. 4th Street, Suite 606 |


WORKING WALL INSTALLATION: Bellevue, WA 98004
LAYOUT AND CONSTRUCTION IS TO START
AT REFRIGERATOR HOLD DIMENSION AND
PROCEED UP THE WALL FROM THAT 6 7 [email protected]
END-FINAL INSTALLATION IS ROD AT P:(425) 598-8516
CLOSET. TO BE SCRIBED AT WALL AS
5 1/2" 6 3/8" PROJECT INFORMATION:
REQUIRED. END OF KITCHEN MUST TERMINATE
AT OUTSIDE FACE OF BATHROOM WALL. 2' - 0 3/4" 2' - 3" 1' - 10 2'
1/8"
- 6" 2' - 6" 5 1/2" 4' - 2 3/4" 2' - 0 1/8" 5' - 1 1/4" 3 1/2" 5 1/2"

5 1/2"
901

5 1/2"
GR-A E
1' - 4"6" 2' - 4" 1' - 0"

2' - 9 1/8"
2' - 7 1/4"
PT-03 SS-01

EQ
R-3 CR-6.1

2' - 10"
CR-6.1
SS-01

SS-01

5 R-1 R-1
7

EQ
IP-6.1
18

3 1/2"
MEDFORD, OR

8' - 10 1/2"
B. FR-4.1
A-453 19
T-01

4' - 8"
OS
WC-12

GR-B
B-01 11 31
J

5' - 7"
31
T-01 R-1
A Prototype Version 3.0

10 1/2"
1' - 1 1/4"
B
1' - 0"
WC-12

R-1
10"

B-05

2' - 10"
7' - 3" 7' - 3"
A.
August 2022
PT-07 PT-07 IP-4.1 A-453
PT-03 WC-12 ISSUE

3 1/2"
902 T DELTA ISSUE DATE DESCRIPTION
NO.
GR-504
11 1/4"

8"
EQ EQ
GR-201 GR-318 6' - 1" 6' - 4"
D
1 A1 2022.11.30 ISSUED FOR
32 12
4 SQUARES

13 45 44 PERMIT
GR-200
1' - 0 7/8"

WAP
21 IF-6.1
8' - 0"

GR-104
8 1/8"

21

520
SD
520

SD
GR-105

7' - 2"
22 45 46 GR-101
CPT-07 33

29' - 3 1/4"
3' - 6"

GR-500
38
GR-205
903 1 31 8
6"

47 GR-404 F 4' - 4"

2' - 1 1/2"
2 A-404 4 9' - 1 3/8"

1' - 1"
8' - 0"
GR-208

20' - 2 3/8"

20' - 4 1/8"
PT-07 KING STUDIO
4' - 0"

4 SQUARES 3 SUITE
KING STUDIO KING STUDIO OS
WC-11
PT-03

904

3 1/2"
SUITE SUITE
KING STUDIO
SUITE 33 GR-317
32
GR-204 GR-301
CPT-01 FLOOR FINISH
8' - 1"

B-01 BASE FINISH GR-601


GR-307
8' - 3 5/8"

REFER TO PRODUCT SPECIFICATION GR-601.1


FOR CARPET INSTALLATION PATTERN GR-603

GR-405 GR-317
30 4
1 GD-6.1 ER-6.1
1' - 11"

6' - 7 1/4" GR-208


PT-01 CURRENT ISSUE:

5 1/2"

5 1/2"
J W1 C
GR-400 5 1/2" 6' - 2 3/4" 6' - 4 3/4" 5 1/2"
905 ISSUE FOR PERMIT
D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN  CURRENT ISSUE DATE:
A-404 1/4" = 1'-0" A-404 1/4" = 1'-0" A-404 1/4" = 1'-0" A-404 1/4" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX 7. USE 9/16TH GRID ON SUSPENDED GRID SYSTEM GRID SUSPENDED FROM STRUCTURE
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
GUESTROOM -
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
KING STUDIO
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS A CEILING FINISH SHEET NUMBER:
9'-6" CEILING HEIGHT

A-404
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


GR-400
2030 Habersham Trce
GR-405 GR-304 GR-201 GR-204 GR-504 PT-03 PT-04 PT-03
WC-11 GR-205 GR-504 Cumming, GA 30041
PT-01 PT-04 PL-01 PT-03 903 GR-500
GR-400 954.812.6650
FIRE ALARM 12
PL-01 [email protected]
901 PT-03 PT-02 PT-03
39
11 4 1/2" 4' - 3 1/4"
GR-301 GR-208 GR-202
GR-301 41
9' - 1 3/8"

9' - 1 3/8"

9' - 1 3/8"

7' - 3"

9' - 1 3/8"
6" 6" 33
44 6" GR-500 901

1' - 4"
GR-202

6' - 7"
7' - 3"

7' - 3"
6' - 10"
4

7' - 0"
903

6' - 6"
W1 GR-200
GR-208 GR-C GR-B

5' - 6"
GR-A GR-201
ST-02

4' - 4"
4' - 0"

4' - 0"
904 GR-205

3' - 6"

3' - 6"
3' - 0"

1' - 6"
GR-317 GR-101

1' - 0"
GR-306 1 GR-603 902 B-01 GR-105 GR-104 GR-304 GR-317 GR-601 GR-101 GR-105 GR-318
B-01 B-01 GR-104 GR-304 GR-306 GR-405 1 904 GR-200 B-01
GR-601.1 GR-601 905 GR-601.1
GR-317
GR-603 11/30/2022 8:26:01
8:17:23 PM
GR-404
OWNER:

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION  4  INTERIOR ELEVATION 


A-405 1/4" = 1'-0" A-405 1/4" = 1'-0" A-405 1/4" = 1'-0" A-405 1/4" = 1'-0"

10655 N.E. 4th Street, Suite 606 |


7 8 Bellevue, WA 98004

5 1/2" 6' - 3 1/4" 6' - 3 7/8" 5 1/2"


[email protected]
GR-317 P:(425) 598-8516
GR-400

5 1/2"

5 1/2"
L PROJECT INFORMATION:
J
1' - 11"
PT-01 W1
2' - 0"

GR-405
GR-208

2' - 0"
30 4 1 GD-6.1 ER-6.1
905
12' - 5 1/8"
KING STUDIO GR-306 GR-301
5' - 0"

SUITE CONN. CLEAR


GR-603

7' - 10 1/4"
CPT-01 FLOOR FINISH 33
GR-601.1 MEDFORD, OR
B-01 BASE FINISH GR-204 GR-601
32
KING STUDIO
6" 2' - 1"

904 SUITE CONN.

18' - 3 1/4"
Prototype Version 3.0
WC-11
PT-03

FULL TILE

2' - 4 3/8" 2 3/4"


903
GR-317 F August 2022

20' - 3 3/8"
1
31 9' - 1 3/8"
8

520

520
SD

SD
OS
8' - 0" GR-202 PT-07 ISSUE
2 A-405 4 DELTA ISSUE DATE DESCRIPTION
3' - 3"

1' - 1"
NO.
22 GR-304 GR-404
4 SQUARES 3
4' - 4" 1 A1 2022.11.30 ISSUED FOR
1' - 7"

CPT-07 GR-104 GR-205 PERMIT


8"

38
21 WAP
4 SQUARES

GR-201 GR-500 KING STUDIO


1' - 7"

7' - 2 1/8"
GR-105 SUITE CONN.
8' - 0"

13
KING STUDIO GR-101 IF-6.1
SUITE CONN.
GR-318 GR-C
12 EQ EQ
32 GR-200
6"

6 3/8"
IP-4.1

3 1/2"
2' - 1 5/8"

1' - 0 1/4"
T
5 1/4"

902 B
PT-03

2' - 0"
WC-12 GR-504 A 6' - 1 1/8"
11 3/8"

R-1 31 7' - 3"


WC-12

7' - 3"

10' - 11 3/8"
T-01 PT-07 R-1
11 WORKING WALL
1' - 3"
1' - 0"
WC-12

7 1/4"

4' - 8"
CT-07 INSTALLATION: 31 19

8' - 7 5/8"
PT-07
J

T-01 LAYOUT AND CONSTRUCTION OS GR-B


6' - 1 1/8" IS TO START AT
B-01 REFRIGERATOR HOLD 2' - 0" 2' - 1 5/8" 18
1' - 0" 2' - 3" 7"

DIMENSION AND PROCEED


36
UP THE WALL FROM THAT

EQ
SS-01

SS-01

2' - 10"
END-FINAL INSTALLATION IS FR-4.1
R-1 R-1
2' - 4"

7 901 ROD AT CLOSET. TO BE


R-3 CR-6.1 IP-6.1

EQ
PT-03 SS-01 SCRIBED AT WALL AS
REQUIRED

5 1/2"

5 1/2"
GR-A F
EQ EQ 5 1/2" 4' - 2 1/4" 2' - 0 1/8" 5' - 11 1/8" 5 1/2"
CURRENT ISSUE:
5 1/2"

ISSUE FOR PERMIT


D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN 
A-405 1/4" = 1'-0" A-405 1/4" = 1'-0" A-405 1/4" = 1'-0" A-405 1/4" = 1'-0"
CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
GUESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
KING STUDIO
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
CONN.
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION A CEILING FINISH
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN 9'-6" CEILING HEIGHT
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-405
0" 1"
GR-400 GR-400

GR-300 PT-03 PT-02 AUDIO/VISUAL AUDIO/VISUAL PT-03


PT-01 WC-11 GR-406 PT-03 GR-204 SMOKE DETECTOR FIRE ALRAM
903
GR-404
GR-504
2901 Clint Moore Rd, #114
GR-500
4
6" 11 Boca Raton, FL 33496
GR-406 39 GR-208 GR-300 GR-208
6"
47 33 888.901.8008 www.base-4.com

7' - 0"
6" 6" GR-300
9' - 1 3/8"

9' - 1 3/8"

9' - 1 3/8"
GR-204 GR-208 ARCHITECT:
W1

4' - 0"
41

3' - 8"
7' - 3"

7' - 3"
Ricardo J. Muniz-Guillet, AIA

4' - 0"

6' - 7"
6' - 6"
903 GR-B

5' - 6"
ST-02 2030 Habersham Trce

5' - 0"
Cumming, GA 30041

1' - 0"
3' - 4"
OPEN 954.812.6650

1' - 9"
1' - 0"
[email protected]

3' - 0"
905 GR-600 B-01 1 B-01 GR-318 GR-101 GR-600 904 GR-600 1
GR-205 GR-307 B-01 GR-104 902 901
GR-601.1 GR-105 GR-601.1 GR-322 GR-601.1 GR-317
GR-200 GR-317 GR-304 GR-201
GR-202 GR-602 GR-602 905 GR-602

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  4  INTERIOR ELEVATION 


A-406 1/4" = 1'-0" A-406 1/4" = 1'-0" A-406 1/4" = 1'-0"

1
A-804 12 13
11/30/2022 8:26:01
8:17:41 PM
OWNER:
5 1/2" 6' - 3 1/2" 6' - 4" 5 1/2"

GR-400 PTAC UNIT

5 1/2"

5 1/2"
W1 M
1' - 6" GR-317 J
PT-01
ER-6.2
GR-202 6' - 2"
30
1 4
GR-406 12' - 5 1/8" 10655 N.E. 4th Street, Suite 606 |
GR-300 Bellevue, WA 98004
GR-602 CLEAR
ER-6.3
7' - 3 1/2"

GR-600.1 [email protected]
32

7' - 6"
QUEEN QUEEN
GR-305
P:(425) 598-8516
STUDIO SUITE GR-600
PROJECT INFORMATION:
CPT-01 FLOOR FINISH GR-322
904
B-01 BASE FINISH GR-202
3"

GR-204
905
22
31
7' - 3 1/2"

32

26' - 3 3/8"

26' - 1 1/2"
F

CLEAR
GR-300
WC-11

1
PT-03

9' -OS
1 3/8"
MEDFORD, OR

8' - 7 1/2"
GR-602
2 A-406 4 PT-07
GR-600.1
GR-600 33 QUEEN QUEEN
8' - 0" 3 Prototype Version 3.0
8 STUDIO SUITE
August 2022
2' - 0 1/2"

35' - 2 1/2"
GR-317 GR-404
4 SQUARES QUEEN QUEEN

1' - 1"
21 GR-202 QUEEN QUEEN
STUDIO SUITE ISSUE
STUDIO SUITE DELTA ISSUE DATE DESCRIPTION

6"
NO.
4' - 4"
CPT-07 GR-205
1 A1 2022.11.30 ISSUED FOR

3' - 9"
903
PERMIT
GR-101

520
SD
7' - 0"

520

SD
GR-500
4 SQUARES

GR-105
1' - 3"
10"
8' - 0"

32 GR-104
GR-200 12
WAP
PT-04
10"
9"

GR-504 GR-201
GR-318 GR-201 IP-4.1 FIRE HORN
22 PL-01
GD-6.1 PT-03

DB
6' - 1"
2' - 11"

3 1/2"
GR-404
8"

2' - 0"
PT-03

6' - 1 1/8" 12
WC-12

3"

WC-12 902
T R-1

4' - 8"
15cd

V
9 1/2"

31 R-1
T-01 T-01

5' - 7"
WC-12

901
4"

B-05 B-01 DB EQ EQ PT-07 GD-6.1

8' - 10 1/2"
PT-03

CLEAR
1' - 0" 1' - 2 1/2"

A GR-B
1' - 0"

9' - 1 3/8"
J

31 19 OS
7' - 3"

3 1/2"
11 B
PT-07 R-3

4' - 10 3/4"

7' - 3"

6' - 10"
7' - 3"
PT-03

GR-A
2' - 5"
6"

EQ
18
SS-01

SS-01

2' - 9 1/8"
2' - 10"
7 R-1
2' - 5"

FR-4.1 CR-6.1

EQ
EQ EQ IP-6.1
SS-01 PT-03 901

5 1/2"
GR-A F
RFID 1' - 11" 6 7/8"

5 1/2"
2' - 2 1/8" 2' - 0" 903 GR-104 B-01 GR-504
WORKING WALL INSTALLATION: 5 1/2" 5' - 1 1/4" 1' - 11 5/8" 4' - 2 3/4" 5 1/2"
LAYOUT AND CONSTRUCTION IS TO GR-304 GR-105 GR-500
START AT REFRIGERATOR HOLD 3 1/2" 5 1/2"
DIMENSION AND PROCEED UP THE CURRENT ISSUE:
WALL FROM THAT END-FINAL
INSTALLATION IS ROD AT CLOSET. TO
D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  BE SCRIBED AT WALL AS REQUIRED B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN  3  INTERIOR ELEVATION  ISSUE FOR PERMIT
A-406 1/4" = 1'-0" A-406 1/4" = 1'-0" A-406 1/4" = 1'-0" A-406 1/4" = 1'-0" A-406 1/4" = 1'-0"

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR
B PRIMED & PAINTED GYPSUM BOARD-MOISTURE PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS
WALLS. 6. ALL ACT TILE CENTERED IN ROOM. D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
7.
8.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS F
GRID SUSPENDED FROM STRUCTURE
UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
GUESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
OTHERWISE NOTED
H
PAINTED
4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
DOUBLE QUEEN
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
J
CLG. GRID SUSPENDED FROM STRUCTURE
PRIME AND PAINTED EXTERIOR GYPSUM BOARD
STUDIO
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION A CEILING FINISH
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN 9'-6" CEILING HEIGHT
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-406
0" 1"
GR-504
GR-400 WC-11 GR-200 PT-03 PT-02 PT-02 AUDIO/ VISUAL PT-03
PT-03 PT-04 PL-01 GR-201 GR-204
GR-404 FIRE ALARAM
GR-400

12 GR-504 901 PT-03


2901 Clint Moore Rd, #114
11
Boca Raton, FL 33496
GR-205 39 903 888.901.8008 www.base-4.com
33 6"

7' - 0"
GR-300 905 904 GR-300 GR-500

4' - 0"
9' - 1 3/8"

9' - 1 3/8"

9' - 1 3/8"
GR-208 GR-208 ARCHITECT:

4' - 0"
GR-200 901 41 6" 44

7' - 3"

7' - 3"

7' - 3"
6' - 10"

Ricardo J. Muniz-Guillet, AIA

6' - 7"

6' - 6"
4' - 4"
GR-A GR-B GR-C

5' - 6"
GR-500 GR-201 2030 Habersham Trce

3' - 10 3/8"
Cumming, GA 30041

1' - 0"

3' - 8"
3' - 6"
954.812.6650

3' - 0"
1' - 9"
GR-101
[email protected]

1' - 6"
1' - 6"
GR-105 B-01 GR-104 GR-304 1 GR-600 GR-322 GR-600 GR-317 B-01 B-01 902 GR-104 GR-307 B-01
GR-205 GR-101 GR-318
GR-317 GR-601.1 GR-601.1 GR-304 GR-405
GR-208 GR-105
GR-602 GR-602

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  4  INTERIOR ELEVATION 


A-407 1/4" = 1'-0" A-407 1/4" = 1'-0" A-407 1/4" = 1'-0"

21 24
11/30/2022 8:26:01
8:17:59 PM
2' - 3 3/4" 6 7/8" OWNER:
EQ EQ 1' - 10" 2' - 0" 5 1/2" 5' - 1 1/4" 2' - 0 1/8" 4' - 2 7/8" 5 1/2"

5 1/2"
3 1/2" 5 1/2"

1' - 0"

5 1/2"
GR-A E
SS-01 PT-03

EQ
18

2' - 6"

2' - 10"

2' - 9"
SS-01

SS-01

FR-4.1

3 1/2"

4' - 10 3/4"
7 901 R-1 R-1 CR-6.1

2' - 5"

EQ
R-3

4"
10655 N.E. 4th Street, Suite 606 |
B Bellevue, WA 98004

10 1/2"
11 19

1' - 0 1/2" 1' - 4"


7' - 3"

4' - 8"
1' - 0 1/2"
OS

11' - 9 3/8"
T-01 T-01 31 31 GR-B

5' - 7"
[email protected]

3 1/2" 3' - 7 5/8"


1 1/2"
CT-07 B-01 R-1 PT-07 A R-1 GD-6.1 6' - 1 3/4" P:(425) 598-8516

J
7' - 3"
WC-12

WC-12

PT-03

2' - 0"
902 PT-07
2' - 11 1/4"2' - 10 5/8" IP-4.1 IP-6.1 PROJECT INFORMATION:
5"

9"
WC-12

3 1/2"

3 1/2"
T
7 7/8"

GR-318
7 1/2"

PT-03 D
21 GR-200
GR-504
32
12 GR-C
6' - 11 7/8"

GR-500
GR-105
4 SQUARES

CPT-07 A
GR-101 MEDFORD, OR
8' - 0"

13

9 3/4"
GR-201 8
GR-205
1 Prototype Version 3.0
August 2022

1' - 1"
2' - 5"

WAP
GR-104

10"
8' - 0" GR-404 2 A-407 4
22 4' - 4" ISSUE
GR-317 GR-304 DELTA ISSUE DATE DESCRIPTION
4 SQUARES NO.
3

5 7/8"
GR-202

4' - 5 1/8"
FULL TILE 903 1 A1 2022.11.30 ISSUED FOR
PERMIT
PT-03
WC-11

26' - 11 1/2"
27' - 1 3/8"
GR-300
7' - 1 5/8"

32 F QUEEN QUEEN
GR-602 9' - 1OS
3/8" 31 STUDIO SUITE

24' - 3 1/4"
CONN. GR-400
GR-600.1
6"
PT-07

520

520
SD

SD
QUEEN QUEEN
STUDIO SUITE GR-600 QUEEN QUEEN
CONN. 33 STUDIO SUITE PT-01
4' - 0"

904 CONN.
3 1/8"

QUEEN QUEEN
STUDIO SUITE
CPT-01 FLOOR FINISH GR-202 12' - 6 3/8"
905 CONN. GR-204
B-01 BASE FINISH
GR-322 CLEAR
GR-300 GR-307
7' - 5 1/2"

32 6" 6"

9' - 1 3/8"
GR-602 W1
6' - 3"

4
GR-600.1
ST-02
GR-600
1
GD-6.1 GD-6.1
GR-317 1
4 GR-317
6 1/2"

30 GR-405
2' - 0 5/8"

2' - 0 1/8"

GR-202 6' - 2 5/8" ER-6.2


PT-01

5 1/2"

5 1/2"
GR-405 B-01
J W1 A
GR-400 5 1/2" 6' - 3 1/2" 6' - 4 5/8" 5 1/2"
PTAC UNIT
CURRENT ISSUE:

D  FLOOR FINISH PLAN  C  FURNITURE AND POWER PLAN  B  REFLECTED CEILING PLAN  A  CONSTRUCTION PLAN  3  INTERIOR ELEVATION  ISSUE FOR PERMIT
A-407 1/4" = 1'-0" A-407 1/4" = 1'-0" A-407 1/4" = 1'-0" A-407 1/4" = 1'-0" A-407 1/4" = 1'-0"

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES GENERAL RCP NOTES CEILING FINISH LEGEND PJ/RG
BASE4 NOTES BASE4 NOTES TYPE CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE 1. REFER TO PLUMBING, MECHANICAL, ELECTRICAL FOR MARK DESCRIPTION
NOTED LOCATIONS OF RELATED ITEMS. A PRIMED & PAINTED GYPSUM BOARD
LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR 2. COORDINATE WITH HVAC AND ELECTRICAL PLANS FOR PROJECT #:
SHEATHING, CMU, & CONCRETE. LOCATIONS/QUANTITIES/TYPES OF DIFFUSERS AND LIGHTS. B PRIMED & PAINTED GYPSUM BOARD-MOISTURE
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF 3. REFER TO ROOM FINISH SCHEDULES FOR CEILING RESISTANT
C OPEN TO UNDERSIDE OF FLOOR/ROOF SYSTEM
B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE. MATERIALS AND HEIGHTS.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS 4. CEILING CONTROL JOINTS TO BE 50'-0" MAX. EITHER ABOVE-PAINT ALL ELEMENTS-ELEVATION INDICATED SHEET NAME:
AS SHOWN ON PLANS. DIRECTION OR TO LIMIT AREAS TO 2500 SF MAY BE "APPROXIMATE"&FOR GENERAL REFERENCE
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU 5. REFER TO CEILING DETAILS FOR FURTHER INFORMATION. ONLY-REFER TO SECTIONS

6.
WALLS.
GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
6.
7.
ALL ACT TILE CENTERED IN ROOM.
USE 9/16TH GRID ON SUSPENDED GRID SYSTEM
D 2X2 LAY-IN ACOUSTICAL CLG. TILE WITH 9/16" CLG.
GRID SUSPENDED FROM STRUCTURE
GUESTROOM
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
8. ALL DIMENSIONS ARE TAKEN FROM FINISHES UNLESS
OTHERWISE NOTED
F UNDERSIDE OF FLOOR/ROOF SYSTEM-PRIMED &
PAINTED
-DOUBLE
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES
H 4'0''X0'8'' LAY-IN ACOUSTICAL CLG. TILE WITH 9/16"
CLG. GRID SUSPENDED FROM STRUCTURE
QUEEN STUDIO
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION. J PRIME AND PAINTED EXTERIOR GYPSUM BOARD CONN.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION A CEILING FINISH
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN 9'-6" CEILING HEIGHT
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-407
0" 1"
GR-203 SHOWER
WC-12 SS-01 PT-04 WC-12 SHOWER
HD-05 SURROUND WC-12 GR-203 HD-5.1 SS-01
GR-503 SURROUND WC-12 PT-04 GR-503 GR-203
GR-203

13 13
10
GR-503 25 13 13
25
2901 Clint Moore Rd, #114
HD-08 TA-08 Boca Raton, FL 33496
GR-503 888.901.8008 www.base-4.com
GR-303
6' - 6 1/4"

6 HD-06 ARCHITECT:
GR-B1

7' - 3"
HD-21 6

6' - 0"
TO REFLECTIVE SURFACE

6' - 6"
HD-10 HD-06 HD-06 GR-B1 Ricardo J. Muniz-Guillet, AIA
HD-10 2030 Habersham Trce
HD-16 HD-02 GR-303 Cumming, GA 30041
HD-09

3' - 5 1/8"
40" MAX

8
7 8 6 HD-08 954.812.6650

2' - 10"

2' - 10"

3' - 6"

3' - 6"

3' - 6"
19 8 6 8 [email protected]

3' - 1"

2' - 10"
HD-16
HD-18

1' - 3"
19

B-05 B-05
B-05 GR-303 B-05

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  5  INTERIOR ELEVATION  6  INTERIOR ELEVATION 


A-450 1/2" = 1'-0" A-450 1/2" = 1'-0" A-450 1/2" = 1'-0" A-450 1/2" = 1'-0"

SHOWER SHOWER GR-203 SHOWER


SHOWER WC-12 WC-12 WC-12 HD-5.1 SS-01 SURROUND WC-12
HD-05 WC-12 WC-12 HD-05 SS-01 SURROUND SURROUND
SURROUND SS-01

HD-5.1
SS-01 11/30/2022 8:26:01
8:18:22 PM
GR-203 10
TA-08
10 TA-08 13 OWNER:
13
25 12 11
25 TA-08
HD-08 GR-503
3
4' - 2 1/4"

3 GR-503
HD-06 HD-08
HD-09
HD-08 HD-06 HD-10

7' - 3"

7' - 3"
11 HD-02

7' - 3"
HD-10 HD-16 HD-9 HD-08 6
HD-08 HD-06 GR-303 TA-06

6' - 0"
6"
7 1/2"

15 10655 N.E. 4th Street, Suite 606 |


6"

HD-06 HD-06
HD-10 HD-09 Bellevue, WA 98004

3"
HD-06
3"

HD-02 HD-02
4' - 0" MAX

7 7 23

1' - 6"

3' - 6"
2' - 10 5/8"
HD-9 7

3' - 1 3/4"
23
8"

2' - 11 1/2"
[email protected]

2' - 11 1/8"
2' - 10 3/4"

11 15 11 3/8" 8
2' - 8 7/8"
3' - 2"

PL-801 MIN 7" 8


P:(425) 598-8516

8"
7 19
1' - 8"

MAX 9" PROJECT INFORMATION:

1' - 4"
19 HD-18

B-517 B-05 GR-303 B-05 HD-08 HD-16 B-517


TA-06 B-05 6 B-05

3  INTERIOR ELEVATION  4  INTERIOR ELEVATION  7  INTERIOR ELEVATION  8  INTERIOR ELEVATION 


A-450 1/2" = 1'-0" A-450 1/2" = 1'-0" A-450 1/2" = 1'-0" A-450 1/2" = 1'-0"
MEDFORD, OR
25 26
26
3 1/2" 5' - 3 1/2" 3 1/2" 2' - 7 3/8" 3 1/2" 5 1/2" 1 1/8"
5 1/2"
Prototype Version 3.0
3 1/2" 5' - 3 1/2" 3 1/2" 2' - 7 3/8" 3 5/8"
1 1/4" August 2022

5 1/2"
GR-303 GR-503

5 1/2"
GR-503 GR-303
ISSUE
5 1/2"

5 1/2"
DELTA ISSUE DATE DESCRIPTION
NO.
E E
J J
1 A1 2022.11.30 ISSUED FOR

1' - 11 1/4"

1' - 11 1/4"
1' - 2"
8 1/8" 9"

IP-4.1 CR-6.1 FR-4.1 ER-6.1 IP-4.1 CR-6.1 FR-4.1 CR-6.1 PERMIT


2' - 6" 13
HD-10
2' - 7"
3' - 11 3/8"

3' - 11 3/8"
HD-08

9"
A

3 1/2"

3 1/2"
FR-4.1 J HD-21 FR-4.1
H
7 HD-10 RESTROOM-
4' - 0"

HD-16 GR-B1 ACCESSIBLE


GR-B1 FR-4.1 HD-05 RIS
M
RESTROOM ACCESSIBLE
9' - 4 1/4"

5' - 1 1/4"

9' - 4 1/4"
FR-4.1

5' - 3 1/4"
3 HD-16
TUB RESTROOM ACCESSIBLE
1
RESTROOM-
HD-05 HD-9 RIS
ACCESSIBLE A
5
TUB
25
2 A-450 4 ER-6.1
5' - 2 1/4" 2' - 10 7/8" 6 A-450 8
HD-09 5' - 2 1/4" 2' - 10 7/8"
5' - 6 7/8"

5' - 6 7/8"
3
3 1/2" B-517

3 1/2"
HD-08 FR-4.1 7 FR-4.1

19 12 PL-801
1' - 10 5/8"

1' - 8 5/8"
HD-10 HD-02
HD-06
IP-4.1 FR-4.1 I IP-4.1 FR-4.1 IP-4.1
IP-4.1
3 1/2"

3 1/2"
D D CURRENT ISSUE:

3 1/2"
3 1/2"

HD-06 HD-08 3 1/2"


HD-06 HD-08 HD-06
HD-02 3 1/2" 5' - 3 1/2" 3 1/2" 2' - 7 3/8" 5 1/2" 3 1/2" 5' - 3 1/2" 3 1/2" 2' - 7 3/8" 5 1/2"
ISSUE FOR PERMIT
3 5/8" 1 1/8"
1 1/4"
B  FURNITURE AND POWER PLAN  A  CONSTRUCTION PLAN  B.  FURNITURE AND POWER PLAN  A.  CONSTRUCTION PLAN 
CURRENT ISSUE DATE:
A-450 1/2" = 1'-0" A-450 1/2" = 1'-0" A-450 1/2" = 1'-0" A-450 1/2" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
BASE4 NOTES CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
NOTED LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
PROJECT #:
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS SHEET NAME:
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
RESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM & ACC. TUB AND
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED RIS
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-450
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


SS-01 2030 Habersham Trce
SHOWER
SHOWER
Cumming, GA 30041
WC-12 PT-04 SURROUND SS-01 TA-08 GR-203
PT-04 WC-12 SURROUND GR-503 WC-12 954.812.6650
25 [email protected]
10 HD-05

HD-05 3
13
3 HD-12

4' - 3 7/8"
HD-08
HD-08

7' - 3"
HD-08

6' - 4"
GR-B1 HD-08 HD-22

7' - 3"
HD-06 12
HD-10 HD-06 15
GR-B1 HD-10

4' - 10 1/2"
HD-06 HD-9 HD-06
HD-9

3"
8 6
HD-02 HD-16 HD-02
7 23 14

8"
3' - 6"

3' - 4"

3' - 4"

3' - 4"
HD-9 7 7/8"

2' - 10"
PL-801 11
11/30/2022 8:26:01
8:18:35 PM
19 HD-02 19 7 OWNER:

B-05 TA-06 GR-303


B-05 B-05

1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION  10655 N.E. 4th Street, Suite 606 |
A-451 1/2" = 1'-0" A-451 1/2" = 1'-0" A-451 1/2" = 1'-0" Bellevue, WA 98004

[email protected]
P:(425) 598-8516
PROJECT INFORMATION:

11 12

3 1/2" 6 3/4" MEDFORD, OR


5' - 2" 3' - 2" 6" 2' - 10" 3 1/2" 7' - 10 5/8" 2' - 1 5/8" 3 1/2" 2' - 6 1/2" 5 1/2"

5 1/2"
HD-06 Prototype Version 3.0
August 2022

5 1/2"
WC-12 SS-01 WC-12 GR-B1
HD-05 3
I FR-4.1 ISSUE

7"
6"

IP-4.1 DELTA ISSUE DATE DESCRIPTION


IP-6.1 NO.
IP-6.1
GR-203 1
HD-10

3 1/2"
TA-08 1 A1 2022.11.30 ISSUED FOR
13 19 FR-4.1 FR-4.1 PERMIT
10 2 A-451 4
9' - 10 7/8" 2' - 10"
3' - 10"

GR-503 3
HD-16

6' - 2 7/8"
HD-02 J 7

5' - 0"

5' - 1 1/4"
HD-10 HD-05
HD-08 M 3
HD-08 RESTROOM ACCESSIBLE
12

CLEAR
6' - 6 1/4"

HD-16 HD-9 GR-303 TUB

8' - 0"
HD-06 HD-9
1' - 7"
3

HD-08 GD-6.1
B

2' - 2 1/8"
12

3 1/2"
SH-3.1 FR-4.1
3' - 3 1/2"

TA-07
MAX 10"

6
MAX 19"MIN 8"

2' - 10"

H HD-10
8
2' - 3"

GR-B1
MIN 17"
1' - 4"

RESTROOM-

1' - 10 5/8"
1' - 0"

7
MIN.

ACC. ONE 6 FR-4.1


1' - 5 5/8"

1' - 11"
2' - 2 3/4"
BEDROOM TUB SH-3.1 SH-3.1
SH-3.1
13 CR-6.1
B-05
PL-801 J

5 1/2"
F

5 1/2"
HD-12 HD-22 GR-503 GR-303 PL-801 3 1/2" 10' - 0 1/8" 3 1/2" 3' - 4 3/4" 5 1/2"
9' - 10 7/8"

12' - 8 7/8"
CURRENT ISSUE:

4  INTERIOR ELEVATION  B  FURNITURE AND POWER PLAN  A  CONSTRUCTION PLAN 


A-451 1/2" = 1'-0" A-451 1/2" = 1'-0" A-451 1/2" = 1'-0"
ISSUE FOR PERMIT

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
BASE4 NOTES CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
NOTED LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
PROJECT #:
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS SHEET NAME:
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
RESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM & ACC. ONE
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED BEDROOM TUB
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-451
0" 1"
2901 Clint Moore Rd, #114
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:

Ricardo J. Muniz-Guillet, AIA


2030 Habersham Trce
Cumming, GA 30041
SS-01
954.812.6650
SHOWER SHOWER [email protected]
WC-12 PT-04 HD-5.1 SURROUND SS-01 PT-04 WC-12 HD-5.1 GR-503 WC-12
SURROUND GR-203

25
10 HD-12
13
TA-08

12 12
HD-12 HD-22
HD-08
HD-22 HD-21
HD-08

7' - 3"

7' - 3"
HD-08

6' - 8"
TA-06 GR-B1 TA-06

6' - 4"
HD-06 HD-06 GR-B1 HD-06

6' - 0"
7' - 3"

3" 6"
GR-303

4' - 10 1/2"
HD-06 HD-12 HD-06 HD-06
HD-09 HD-09
6
HD-02 HD-02
HD-16 HD-16
11/30/2022 8:26:01
8:18:47 PM

3' - 4"

3' - 4"

3' - 4"
MAX 36"
7

MIN 33"
HD-06

2' - 10"

2' - 10"
8
OWNER:
HD-02 HD-18
19 19
MIN 7"

MAX 9"
B-05 B-517 HD-08 GR-303 B-05
B-05

10655 N.E. 4th Street, Suite 606 |


Bellevue, WA 98004
1  INTERIOR ELEVATION  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION 
A-452 1/2" = 1'-0" A-452 1/2" = 1'-0" A-452 1/2" = 1'-0" [email protected]
P:(425) 598-8516
PROJECT INFORMATION:

11 12

3 1/2" 7' - 9 1/2" 2' - 2 5/8" 3 1/2" 2' - 6 1/2" 3 1/2" 5 1/2"
MEDFORD, OR

5 1/2"
HD-06 6 3/4"

5 1/2"
GR-B1
Prototype Version 3.0

7 1/2"
SHOWER
SURROUND
I B-517 August 2022
19 IP-4.1 IP-6.1 FR-4.1
WC-12 HD-5.1 SS-01 WC-12 ISSUE

3 1/2"
9' - 10 7/8" 2' - 10" DELTA ISSUE DATE DESCRIPTION
HD-06 NO.
7
1 FR-4.1
1 A1 2022.11.30 ISSUED FOR
PERMIT
13

6' - 5 5/8"
2 A-452 4
HD-02 M

5' - 3 1/2"
TA-08 HD-05 FR-4.1
3 10 HD-08 RESTROOM- B
25

8' - 2 3/4"
3 ACC. ONE 12

CLEAR
BEDROOM RIS TA-06 RESTROOM ACCESSIBLE
12 B RIS
HD-08 GR-503
15 HD-16
HD-08 3
7' - 3"

11 GR-303 HD-09
6 J HD-10

3 1/2"
6' - 0"

H HD-21 FR-4.1
GR-B1
6
3' - 6"

7 HD-10

1' - 10 5/8"
2' - 10"

1' - 11"
8 CR-6.1 FR-4.1 GD-6.1
13
HD-18

5 1/2"
F
HD-09 HD-21 B-05

5 1/2"
B-517
3 1/2" 10' - 0 1/8" 3 1/2" 2' - 6 1/2" 3 1/2" 5 1/2"
HD-16
HD-12 HD-22 GR-503 GR-303
6 3/4"

CURRENT ISSUE:

4  INTERIOR ELEVATION  B  FURNITURE AND POWER PLAN  A  FURNITURE AND POWER PLAN  ISSUE FOR PERMIT
A-452 1/2" = 1'-0" A-452 1/2" = 1'-0" A-452 1/2" = 1'-0"

CURRENT ISSUE DATE:

2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
BASE4 NOTES CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
NOTED LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
PROJECT #:
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS SHEET NAME:
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
RESTROOM -
7.
GYPSUM WALLBOARD.
REFER TO G-002 FOR ACCESSIBLE GUESTROOM & ACC. ONE
8.
COMMUNICATION ROOM TABLES
REFER TO SHEETS STARTING ON A-400 FOR ENLARGED BEDROOM RIS
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-452
0" 1"
HD-22 WCL-01 HD-02 HD-12 GF-302 GF-503 GR-203
SHOWER
SS-01 SURROUND HD-22 WC-12 GR-203

12

6 5/8" 9 3/8"
J
13

1' - 11 7/8"
HD-21 13
1' - 5" 1' - 11 3/4" 2' - 9 1/8" 25
2901 Clint Moore Rd, #114

3
HD-12
6 Boca Raton, FL 33496
HD-21
19 888.901.8008 www.base-4.com
18
1 2' - 10 1/8" ARCHITECT:
18

7' - 3"

6' - 2" A.F.F.


Ricardo J. Muniz-Guillet, AIA

6' - 8"
2 A-453 4 6

6' - 2"
2030 Habersham Trce

REFLECTIVE SURFACE
40" MAX BOTTOM OF
3 Cumming, GA 30041

5' - 0"
ONE 954.812.6650
HD-8 [email protected]

2' - 10" MAX.


BEDROOM
SHOWER
HD-21
3

T 19

TA-06 HD-16 HD-12 HD-03 GR-503 GR-302


B-05 WCL-01 HD-02

B  FURNITURE AND POWER PLAN  1  INTERIOR ELEVATION 


A-453 1/2" = 1'-0" A-453 1/2" = 1'-0"

2 5 1/2" 2' - 9" 3 1/2" 9' - 1 1/4"


3 3 1/2"

11/30/2022 8:26:01
8:19:09 PM
5 1/2"

SS-01 WC-12 SHOWER OWNER:


D WC-12 SURROUND PT-04 WC-12

5 1/2"
FR-4.1 ST-6.1 FR-6.1 IR-6.1 13
3 1/2"
1 7/8"

GR-203
FR-4.1 IP-4.1
HD-16

3' - 7 5/8"
RESTROOM HD-12
10655 N.E. 4th Street, Suite 606 |
5' - 11 1/2"

3' - 0" SHOWER 9' - 0" TA-06


5' - 5 3/8"

HD-12 Bellevue, WA 98004


5' - 1 1/4"

HD-21
GR-503
18 [email protected]

7' - 3"

7' - 3"

7' - 3"
ER-6.1 GR-B
GR-B GR-B P:(425) 598-8516
HD-8 PROJECT INFORMATION:
1' - 11"

IP-4.1

4' - 0"

3' - 6"
3 1/2"

HD-18
3 1/2"

GR-B 19

5 1/2" 12' - 1 3/4" 3 1/2"


GR-302 B-05
MEDFORD, OR
5' - 4 1/4" WCL-01 B-05

A  CONSTRUCTION PLAN  2  INTERIOR ELEVATION  3  INTERIOR ELEVATION  4  INTERIOR ELEVATION  Prototype Version 3.0
A-453 1/2" = 1'-0" A-453 1/2" = 1'-0" A-453 1/2" = 1'-0" A-453 1/2" = 1'-0"
August 2022
7 ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.
HD-21 5 1/2" 5' - 1 1/4" 6 3/8" 5 1/2"
5 1/2"

HD-18 HD-16 1 A1 2022.11.30 ISSUED FOR


3 1/2"
PERMIT
5 1/2"

E
SHOWER
HD-21 SURROUND
CR-6.1 FR-4.1 SS-01 SHOWER GR-203
WC-12 WC-12 PT-04 GR-503 WC-12 SS-01 HD-22 WC-12 HD-12
2' - 9 1/8"

IP-6.1 IF-6.1 SURROUND

13 13
3' - 0"

HD-16
GR-203
4' - 11 1/2"

10
13
HD-8
3 1/2"

FR-4.1 GR-503 HD-16


25
18 HD-21
HD-21
5 HD-22 GR-302
GR-503
19 HD-21
6 A-453 8 WCL-01 6 25 15 18
7' - 3"

7' - 3"

7' - 3"

7' - 3"
6 6

6' - 2" A.F.F


GR-B

6' - 8"

6' - 8"
7 RESTROOM- RESTROOM- GR-B
5' - 5 3/4"

5' - 7"

STANDARD STANDARD HD-8


SHOWER HD-12 SHOWER
3' - 8 1/8"

4' - 0"

2' - 10" MAX.


3' - 6"

3' - 6"
2' - 10"

3' - 0"
4 5/8"

2"

2' - 10 3/8" 5' - 9 1/4" 8


19 19
1' - 0 5/8"

CLEAR
9 7/8"

13 6 IP-4.1
T J CURRENT ISSUE:
3 1/2"

3 1/2"

WCL-01 B-05 HD-18 HD-03 GR-302 B-05 B-05 WCL-01 GR-302


B-05
5 1/2" 5' - 11 1/8" 5 1/2"
ISSUE FOR PERMIT
GR-503 GR-302

B.  FURNITURE AND POWER PLAN  A.  INTERIOR ELEVATION  5  INTERIOR ELEVATION  6  INTERIOR ELEVATION  7  INTERIOR ELEVATION  8  INTERIOR ELEVATION  CURRENT ISSUE DATE:
A-453 1/2" = 1'-0" A-453 1/2" = 1'-0" A-453 1/2" = 1'-0" A-453 1/2" = 1'-0" A-453 1/2" = 1'-0" A-453 1/2" = 1'-0"
2022.11.30
DRAWN BY:
GENERAL FLOOR PLAN NOTES PJ/RG
BASE4 NOTES CHECKED BY:
1. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE
NOTED LA/RB
2. EXTERIOR GRIDLINE ALIGNMENT IS ON FACE OF EXTERIOR
PROJECT #:
SHEATHING, CMU, & CONCRETE.
3. INTERIOR GRIDLINE ALIGNMENT IS ON CENTERLINE OF B4-250-2101
METAL OR WOOD STUDS, CMU, & CONCRETE.
4. INTERIOR DOORS TO BE MIN. OF 4" FROM ADJACENT WALLS SHEET NAME:
AS SHOWN ON PLANS.
5. PROVIDE MASONRY CONTROL JOINTS IN EXTERIOR CMU
WALLS.
6. GYPSUM WALLBOARD CONTROL JOINTS TO BE 30'-0" MAX
O.C. AND AT DOOR JAMBS FROM HEAD TO TERMINATION OF
GYPSUM WALLBOARD.
RESTROOM -
7. REFER TO G-002 FOR ACCESSIBLE GUESTROOM &
COMMUNICATION ROOM TABLES SHOWER
8. REFER TO SHEETS STARTING ON A-400 FOR ENLARGED
GUESTROOM INFORMATION.
9. GC TO REFER TO ENLARGED PLANS AND CONSTRUCTION
DETAILS FOR BUILDING PURPOSES. OVERALL FLOOR PLAN
ONLY INTENDED FOR OVERALL ITEMS, NOT FOR DETAILS SHEET NUMBER:

A-453
0" 1"
4
A-800.C
2901 Clint Moore Rd, #114
SLOPE 1/4:/FT
Boca Raton, FL 33496
888.901.8008 www.base-4.com
ARCHITECT:
4' - 6"
LEAD FLASHING 12'' OUT AND
REMOVABLE ROOF DOME
Ricardo J. Muniz-Guillet, AIA
TURNED UNDER FLANGE 2030 Habersham Trce
OVERFLOW ROOF GRAVEL STOP AS REQUIRED Cumming, GA 30041
ROOF DRAIN DRAIN 954.812.6650

2'-0"
[email protected]
3 3 SLOPE 1/4:/FT
SLOPE 1/4:/FT A-800.C A-800.C

ADJUSTABLE COLLAR
TAPERED
INSULATION

ROOF DRAIN OVERFLOW ROOF DRAIN

SLOPE 1/4:/FT NOTE:


1. CONTRACTOR SHALL VERIFY THAT INSTALLATION IS IN COMPLIANCE
WITH ROOFING MANUFACTURERS RECOMMENDATIONS.
2. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ROOF
CONSTRUCTION.
3.REFER TO SCHEDULE SHEET P-401 FOR RD/ORD SPECIFICATION 11/30/2022 8:26:01PM
22/12/01 8:12:15 PM
OWNER:

6  ROOF DRAIN DETAIL  3  ROOF DRAIN DETAIL2 


A-800.C 3/4" = 1'-0" REF: A-105 A-800.C 3/4" = 1'-0" REF: A-800.C

M N
TELESCOPING THIS DETAIL IS TYPICAL, 10655 N.E. 4th Street, Suite 606 |
HANDRAIL - FASTEN REFER TO MECHANICAL Bellevue, WA 98004
PARAPET-3 DRAWINGS FOR EXACT
EPDM ROOF TO STEEL STRINGER
51' - 6 1/2" LOCATION
SYSTEM
EXTEND OVER
8'-0" MIN [email protected]
1/2" EXTERIOR GRADE WOOD SUPPLY OR
1/2" EXTERIOR GRADE WOOD CURB P:(425) 598-8516
SHEATHING RETURN DUCT FACTORY FABRICATED
SHEATHING
2X6'' WOOD STUD VANES (TYPICAL) PROJECT INFORMATION:
1/2" EXTERIOR GRADE WOOD 1" THICK EXTERNAL
SHEATHING INSULATION - SEE MECH
SEALANT
PR-6.1 PARAPET-2 CLAMPING RING
49' - 1 5/8" METAL STORM COLLAR
TRANSITION FROM DUCT
PROFILE TO CURB TREATED 2x4 WOOD FRAMING
1/4" / 1'-0"
PARAPET-1 2'-6"x8'-0" ROOF HATCH 1/2" EXTERIOR MEMBRANE FLASHING
BOLT
SC-02 47' - 1" STRINGER
SEE SPECIFICATIONS SHEATHING BOARD MEDFORD, OR
TO SLAB TAPERED INSULATION
STRAIGHT STEEL
PR-6.1
HANDRAILS BOTH SIDES
1/2"
5/8"

ROOF LEVEL 9" 3/4" EXTERIOR GRADE ROOF Prototype Version 3.0
45' - 5 3/8" August 2022
1' - 4 7/8"

19" MAX. VERTICAL SHEATHING


1' - 2"

DISTANCE BETWEEN
1/2"

12" TREAD WIDTH TREADS 18" ENGINEERED WOOD I JOIST ISSUE


DELTA ISSUE DATE DESCRIPTION
ALTERNATING NO.
1/2" RESILIENT
5/8"
5/8"

ER-6.1 EACH SIDE. R-1


9" DEEP TREADS WITH CHANNEL
5/8" GYP. BD. - FIRE RATED ALTERNATING RISERS 1 A1 2022.11.30 ISSUED FOR
R1
(REFER TO UL) 5/8'' FIRE RATED PERMIT
5/8" GYP. BD. - FIRE RATED GYPSUM BOARD
(REFER TO UL) 1/2" RESILIENT CHANNEL REFER TO UL
5/8" GYP. BD. - FIRE RATED 2X6'' WOOD STUD 5/8'' FIRE RATED
(REFER TO UL) 1/2" EXTERIOR GRADE WOOD GYPSUM BOARD RIGID INSULATION
SHEATHING REFER TO UL
1/2" RESILIENT CHANNEL
INTERNAL LINER REFER

°
SINGLE PLY ROOF

.00
1/2" 5 1/2"
14" PRE-ENGINEERED I JOIST 3/4" 1/2" MECHANICAL DRAWINGS SYSTEM - SEE SPECS

68
5/8" APA EXTERIOR GRADE
WOOD SHEATHING 7 1/4"
1/2" COVER BOARD+ 60 MIL SEE MECHANICAL FOR
TPO ROOF MEMBRANE CONTINUATION

8  WALL SECTION@ELEC/PBX  5  ROOF ACCESS LADDER DETAIL  NOTE:


2  ROOF DUCT/EQUIPMENT PENETRATION 
A-800.C 1/2" = 1'-0" REF: A-701 A-800.C 1/2" = 1'-0" REF: A-321 G.C. TO SUBMIT SHOP DWGS. FOR ARCHITECT APPROVAL. A-800.C 1" = 1'-0"

THIS DETAIL IS TYPICAL,


REFER TO MECHANICAL
DRAWINGS FOR EXACT
LOCATION
THIS DETAIL IS TYPICAL,
PIPE: SIZE AND ROOF DRAIN - SEE PLUMBING REFER TO MECHANICAL
CURRENT ISSUE:
MATERIAL DRAWINGS FOR EXACT
ROOF SUMP RECEPTOR
VARIES - REFER LOCATION
STACK PIPE FLASHING MEMBRANE BASE FLASHING APPLIED AT
PLUMBING SINGLE PLY ROOF
DRAWINGS SYSTEM - SEE SPECS CLAMP AND SEALANT AT PERIMETER OF PREMOULDED LEAD VENT PIPE
COVER PERIMETER WITH 22'-0" SQUARE
ISSUE FOR PERMIT
LAP SEALANT TOP OF PREMOLDED
SEALANT EAD VENT PIPE COVER FLANGE
TAPERED INSULATION
ROOF MEMBRANE ADHERED TO TAPERED CURRENT ISSUE DATE:
TAPERED INSULATION 5/8" EXTERIOR GRADE POLYISOCYANURATE INSULATION ADHERED
STAINLESS STEEL

8"
ROOF TO TOP PRECAST CONCRETE ROOF PLANKS 2022.11.30
CLAMPING RING
RIGID INSULATION SHEATHING
SINGLE PLY ROOF SYSTEM DRAWN BY:
- SEE SPECS
PROVIDE SLOPE TO PJ/RG
ROOF DRAIN CHECKED BY:
RIGID INSULATION LA/RB
UNDERLOCK CLAMP SEAL
5/8" EXTERIOR GRADE ROOF PERIMETER OF PROJECT #:
SHEATHING PIPE
PENITRARION
B4-250-2101
2x TREATED WOOD R-1
NAILERS SHEET NAME:
R-1
R-1
1' - 6"

14" ENGINEERED WOOD I SEE PLUMBING FOR


5/8'' FIRE RATED GYPSUM
JOIST CONTINUATION
BOARD REFER TO UL
5/8'' FIRE RATED GYPSUM CONST. DETAILS
BOARD REFER TO UL R-38 KRAFT PAPER FACED BATT
1/2" RESILIENT CHANNEL INSULATION INSTALLED TIGHT
TO
@ ROOF
5/8'' FIRE RATED GYPSUM 1/2" RESILIENT CHANNEL
THE BOTTOM OF ROOF
BOARD REFER TO UL
14" ENGINEERED WOOD I SHEATHING
5/8'' FIRE RATED GYPSUM NOTE: COORDINATE LOCATION OF ROOF DRAINS W/ STRUCTURAL JOIST
BOARD REFER TO UL SHEET NUMBER:

A-800.C
7  ROOF VENT STACK PENETRATION  4  ROOF DRAIN PENETRATION  1  ROOF CONDUIT PENETRATION 
A-800.C 1 1/2" = 1'-0" A-800.C 1 1/2" = 1'-0" REF: A-800.C A-800.C 1" = 1'-0"

0" 1"
2

B A

5 1/2"

2901 Clint Moore Rd, #114


5 1/2"
Boca Raton, FL 33496
ER-6.1 888.901.8008 www.base-4.com
1/2" EXTERIOR GRADE WOOD ARCHITECT:
QUEEN QUEEN
STUDIO SUITE W1 M SHEATHING
Ricardo J. Muniz-Guillet, AIA
232 2X6'' WOOD STUD GENERAL CONSTRUCTION 2030 Habersham Trce
1/2" RESILIENT CHANNEL
W1 DETAIL NOTES Cumming, GA 30041
7
5/8" GYP. BD. - FIRE RATED 954.812.6650
1'' 2500PSI MIN GYPCRETE A-812 1. DETAILS ON THIS SHEET ARE TYPICAL FOR ALL SIMILAR
(REFER TO UL) CONDITIONS UNLESS OTHERWISE NOTED
[email protected]
UNDERLAYMENT QUEEN QUEEN
STUDIO SUITE 2. REFER TO STRUCTURAL PLANS FOR LOCATION OF SHAFT
1/4" SOUND MAT PTAC UNIT KING ONE (THAT REQUIRE OPENING IN THE FLOORS)
3/4" APA WOOD FLOOR 231 BEDROOM 3. REFER TO A-020 SERIES SHEETS FOR EXACT DETAILS OF
SHEATHING SUITE WALL AND FLOOR ASSEMBLIES
ER-6.2 106 F1 4. REFER TO A-600 SERIES SHEETS FOR EXACT LOCATION OF
EXTERIOR FINISHES
2ND FLOOR 2ND FLOOR 1ST FLOOR
13' - 8 1/4" 13' - 8 1/4" 4" CONCRETE S.O.G. 0"

1' - 5 3/4"
1' - 2"

1' - 2"
RD/ORD COMPACTED VAPOR BARRIER
GRANULAR FILL
REINFORCEMENT, SEE
FOUNDTAION NOTES
FR-4.1

1' - 4"
F2
F2
T.O. FOOTING
5/8" FIRE RATED GYPSUM -2' - 0"
5/8" FIRE RATED GYPSUM BOARD 11/30/2022 8:26:01PM
22/12/01 8:12:18 PM
BOARD 5/8" FIRE RATED GYPSUM
R3 BOARD OWNER:
5/8" FIRE RATED GYPSUM
BOARD REFER TO SE DRAWINGS
16'' WOOD JOIST 1/2" RESILIENT CHANNEL
INTUMESCENT PAINT FOR FOUNDATION
1/2" RESILIENT CHANNEL J C DESIGN
10' - 8"
TO BE USED FOR FIRE 5/8" GYP. BD. - FIRE RATED
14" PRE-ENGINEERED I JOIST RATING 12' - 2 3/8"
(REFER TO UL)
REFER TO STRUCTURAL 5/8" GYP. BD. - FIRE RATED
DRAWINGS FOR STEEL (REFER TO UL)
BEAM DETAILS CANOPY
1/2" RESILIENT CHANNEL
1 HR BEAM WRAPPING
10655 N.E. 4th Street, Suite 606 |
L-524 5/8" APA EXTERIOR GRADE Bellevue, WA 98004
WOOD SHEATHING
A 5 1/2"
1/2" COVER BOARD+ 60 MIL 8' - 10" [email protected]
TPO ROOF MEMBRANE P:(425) 598-8516
PROJECT INFORMATION:

1  EXT WALL @PORTE COCHERE  2  EXT WALL @POOL DECK  3  EXT WALL @GUESTROOM 
A-801.B 3/4" = 1'-0" REF: A-700 A-801.B 3/4" = 1'-0" REF: A-700 A-801.B 3/4" = 1'-0" REF: A-700
MEDFORD, OR

Prototype Version 3.0


August 2022
ISSUE
DELTA ISSUE DATE DESCRIPTION
NO.

1 A1 2022.11.30 ISSUED FOR


PERMIT

19 F E

1'' 2500PSI MIN GYPCRETE


UNDERLAYMENT
1/4" SOUND MAT 5 1/2"
1'' 2500PSI MIN GYPCRETE 5 1/2" 3/4" APA WOOD FLOOR
UNDERLAYMENT SHEATHING
1/4" SOUND MAT BOTTOM PLATE
3/4" APA WOOD FLOOR GD-6.1 THRU-BOLT GR-A
SHEATHING 2ND FLOOR 2ND FLOOR
13' - 8 1/4" 13' - 8 1/4"
9 1/4"

F2
1' - 2"

1' - 2"

1' - 2"
F2

CURRENT ISSUE:
F2
F3
ISSUE FOR PERMIT
14" PRE-ENGINEERED I JOIST
1/2" RESILIENT CHANNEL REFER SE DRAWINGS FOR
TOP FLANGE HANGER FRAMING DETAILS
14" PRE-ENGINEERED I JOIST CURRENT ISSUE DATE:
5/8" FIRE RATED GYPSUM REFER SE DRAWINGS FOR 1/2" RESILIENT CHANNEL 1 HR BEAM WRAPPING 2022.11.30
BOARD FRAMING DETAILS L-524
5/8" FIRE RATED GYPSUM DRAWN BY:
5/8" FIRE RATED GYPSUM 1 HR BEAM WRAPPING
BOARD TOP FLANGE HANGER
BOARD L-524
5/8" FIRE RATED GYPSUM PJ/RG
BOARD CHECKED BY:

LA/RB
PROJECT #:

B4-250-2101
SHEET NAME:

CONST. DETAILS
@ EXT. WALLS &
BEAM
5  BEAM WRAPPING-1  6  BEAM WRAPPING @ CORRIDOR  WRAPPING
A-801.B 3/4" = 1'-0" REF: A-600 A-801.B 3/4" = 1'-0" REF: A-601

SHEET NUMBER:

A-801.B
0" 1"

You might also like